Laserfiche WebLink
Bowers Museum Access Compliance Survey Report 1 -0 -1 <br />Facility: Bowers Museum Part: Exterior Floor: On -site <br />Address: 2002 N Main St, Santa Ana, CA 92706 <br />Existing Architectural Barrier <br />Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit <br />81= <br />158 • As -Built Description: PCODE EBOSA <br />Level (1:48 %) max. landing for ramp not provided. <br />ADAAG 4.8,4 <br />• As- Built: 2.4% at top landing ADA 2010 405.7.1 <br />• Proposed Solution: <br />Rebuild to provide landings for each ramp run with CBC 2010 1133B.5.4.1 <br />slopes no greater than (1:48 %) CBC 2013 11B- 405.7.1 <br />Ton and Bottom Extension at <br />160 • As -Built Description: <br />Ramp handrail does not extend horizontally 12" <br />past top and / or bottom of ramp. <br />• As- Built: 10" <br />• Proposed Solution: <br />Provide ramp handrail extension. <br />yes • As -Built Description: <br />Ramp handrail does not extend horizontally 12" <br />past top and / or bottom of ramp. <br />• As -Built Bottom not parallel to landing. ends <br />short. <br />• Proposed Solution: <br />Provide ramp handrail extension. <br />PCODE ED05 <br />ADAAG 4.8.5(2) <br />ADA 2010 505.10.1 <br />CBC 2010 1133B.4.2.2 & <br />CBC 2013 10- 505.10.1 <br />PCODE ED05REF <br />ADAAG 4,8,5(2) <br />ADA 2010 505.10.1 <br />CBC 2010 1133B.4.2.2 & <br />CBC 2013 11B- 505.10.1 <br />35 SF <br />4 JOB <br />REF <br />August 27, 2014 Sally S w a n s o n A r c h i t e c i s , Inc. P r o j e c 1 8 14048 Survey Data - Page 21 <br />