Laserfiche WebLink
Bowers Museum Access Compliance Survey Report 1 -0 -1 <br />Facility: Bowers Museum Part: Exterior Floor: On -site <br />Address: 2002 N Main St, Santa Ana, CA 92706 <br />Existing Architectural Barrier <br />Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit <br />Route Sign <br />iae - As -Built Description: <br />PCtrDE SA20 <br />No sign by inaccessible route directing persons to <br />an accessible route. <br />ADAAG 35.163 (b) <br />• Proposed Solution: <br />ADA 2010 216.3 <br />Provide directional sign. <br />CBC 2010 1127B.3 <br />Ton & Bottom Extension at Stairs <br />312 • As -Built Description: <br />PCCDE ED06 <br />Stair handrail does not extend horizontally 12" <br />minimum beyond top nosing, and one tread width <br />ADAAG 4.9.4 (2) <br />sloped, plus 12" minimum horizontally beyond the <br />ADA 2010 505.10.2; 505.103 <br />bottom nosing, <br />CBC 2010 1133B.4.2.2 <br />• Proposed Solution: <br />CBC 2013 iiB- 505.10.2; 11B <br />Extend stair handrail at top and bottom. <br />- 505.10.3 <br />Tread Surface <br />3113 • As -Built Description: <br />7 of the tread does not have compliant <br />PCCDE ECO2 <br />The leading �" p <br />visual contrast of dark--omrlight or light -on- -dark ADA 2010 504.4 <br />from the remainder of the tread. CBC 2010 1133B.4A <br />• Proposed Solution: CBC2013 rlB- 504.41 <br />Provide contrasting color stripes at all exterior stair <br />treads. <br />1 JOB <br />IIm. <br />48 LF <br />August 27, 2014 S a l l y S n, a n s o n A r c h i t e c t s, Inc. P r o J e c i 8 14048 Survey Data - Page 15 <br />