Laserfiche WebLink
Bowers Museum Access Compliance Survey Report 1 -0 -1 <br />Facility: Bowers Museum Part: Exterior Floor: On -site <br />Address: 2002 N Main St, Santa Ana, CA 92706 <br />Existing Architectural Barrier <br />Item No. & Name and Proposed Solution <br />Tabl <br />lei • As -Built Description: <br />Knee clearance at minimums 27" high, 30" wide, <br />and 19" deep is not provided. <br />As- Built: 16" deep to leg & <br />lip at base. <br />• Proposed Solution: <br />Modify table as required to provide compliant knee <br />clearance. <br />Tread Surface <br />152 • As -Built Description: <br />The leading 2" of the tread does not have compliant <br />visual contrast of dark -0n —light or light —on —dark <br />from the remainder of the tread. <br />• As- Built: Striping has deteriorated <br />• Proposed Solution: <br />Provide contrasting color stripes at all exterior stair <br />treads. <br />Codes I Mitigation Info <br />PCODE N1111A <br />ADAAG 16.5.4. <br />ADA 2010 902.2 <br />CBC 2010 1132B.1 <br />PCODE ECO2 <br />ADA 2010 504.4 <br />CBC 2010 1133B.4.4 <br />CBC 2013 1113- 504.4.1 <br />Qty Unit <br />2 JOB <br />22 LF <br />low <br />August 27, 2014 Sally Svanson Arehile cts, Inc. Project #14048 Survey Data - Page 18 <br />