Laserfiche WebLink
Bowers Museum Access Compliance Survey Report <br />Facility: Bowers Museum Part: Interior Floor: Ground Floor <br />Address: 2002 N Main St, Santa Ana, CA 92706 <br />Existing Architectural Barrier <br />Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit <br />Alarm Signal <br />201 • As -Built Description: <br />At facility with a fire alarm system, visual signal PCODE IC05 <br />(strobe) not provided at required type of common <br />ADAAG 4,1.3(14) & 4.28.3 <br />use area. ADA 2010 2151 & 702.1 <br />• Proposed Solution: CBC 2010 1114B.2.2 <br />Provide combination visual J audible signal device <br />connected to existing fire alarm system. <br />Door Closer <br />204 • As -Built Description: <br />Excessive force required to open door. PCODE ID03 <br />ADAAG 4.13.11 <br />• As- Built. 11 Ibs ADA 2010 404.2.9 <br />• Proposed Solution: <br />Adjust regular door closer to accessible standards (5 CBS 2010 1133B.2.5 <br />Ibs max). CBC 2013 11B- 404.2.9 <br />Door Awing <br />200 • As -Built Description: <br />PCODE ID24A <br />Front approach: At push side, door does not have <br />clear and level maneuvering space measuring door <br />ADAAG Fig. 25(a) <br />width x 48" (door width plus 12" if door has both, <br />ADA 2010 404.2.4 <br />latch and closer). <br />CBC 2010 11B 26A(a) <br />• As- Built. 4" to bench <br />CBC 2013 11B- 404.14 <br />• Proposed Solution: <br />Remove or relocate furniture or storage items. <br />1 JOB <br />1 JOB <br />1 JOB <br />August 27, 2014 Sall), S w a n s o n A r c h i t e c t s, Inc. P r o j e c t# 14048 Survey Data - Pape 36 <br />