Loading...
HomeMy WebLinkAbout75B - PH - BUILDING AND FIRE CODES REQUEST FOR COUNCIL ACTION CITY COUNCIL MEETING DATE:CLERK OF COUNCIL USE ONLY: NOVEMBER 19, 2019 TITLE:APPROVED As Recommended As Amended PUBLIC HEARING –RESOLUTION AND st Ordinance on 1Reading ORDINANCE ADOPTING THE UPDATED nd Ordinance on 2Reading CALIFORNIA AND INTERNATIONAL Implementing Resolution Set Public Hearing For__________ BUILDING AND FIRE CODES WITH AMENDMENTAND REQUISITE FINDINGS {STRATEGIC PLAN CO. 3, 3} CONTINUED TO /s/ Kristine Ridge FILE NUMBER CITY MANAGER RECOMMENDED ACTION 1.Adopt a resolution setting forthfindings for required amendments, modifications and changes with respect to the local climatic, geographical and topographical conditions within the City of Santa Ana to the California Building, Residential, Green Standards, Energy, Electrical, Mechanical, Plumbing, and Fire Codes as amended by the State of California. 2.Adopt an ordinance amending Chapters8 and 14 of the Santa Ana Municipal Code adopting the State Building Regulations, including the 2018International Property Maintenance Code,and certain modifications and changes with respect to local climatic, geographical and topographical conditions with the City of Santa Ana to the California Building, Existing Building, Residential, Green Standards, Electrical, Mechanical, Plumbing, Energy, and Fire Codes as amended by the State of California. DISCUSSION The State’s Healthand Safety Code (Section 17958) mandates that the California Building Standards Commission adopt and publish the California Building Standard Code (Title 24 California Code of Regulations) every three years. The 2019Edition of the California Code of Regulations Title24, which incorporates the model codes, becomes effective statewide on January 1, 2020. This Ordinance would amend Santa Ana Municipal Code Sections by repealing references to the prior editions of the Construction Codes. Resolution and Ordinance Adopting Updated California and International Building and Fire Codes November 19, 2019 Page 2 The Construction Codes proposed for adoption by reference with amendments include the following: 1.2019California Building Code 2.2019California Residential Code 3.2019California Green Building Standards Code 4.2019California Electrical Code 5.2019California Mechanical Code 6.2019California Plumbing Code 7.2019California Energy Code 8.2019California Fire Code 9.2019California Existing Building Code 10.2018International Property Maintenance Code The Planning & Building Agency and Orange County Fire Authority are recommending that certain changes and modificationsbe made to the 2019Editions of the California Building, Residential, Green Standards, Plumbing, Mechanical, Electrical, Fire, and Existing Building Codes that are reasonably necessary due to local conditions in the City of Santa Ana. Other modifications are of an administrative or procedural nature and concern themselves with subjects that are not covered by the Codes or are reasonably necessary to safeguard life and property within the City of Santa Ana. There are a total of seventy-one (71) findings in the Resolution which address twelve (12) amendments to the Residential Code, forty-nine (49) amendments to the Fire Code, and ten (10) amendments to the Building Code (Exhibit 1). The changes to the 2019 CaliforniaCodes as adopted by the State include revisionsto enhance clarity and consistency in the application of the Codes. For example, the structural engineering requirements of the building code has been aligned with major revisions to national standards for structural steel and masonry construction,which stem from research studies from recent seismic and high wind events. In the Green Building standards, electric vehicle charging infrastructure will be required for new parking areas. Also,the California Energy Commission has adopted new requirements for the mandatory installation of solar photovoltaic systems onnew homes. FISCAL IMPACT There is no fiscal impact associated with this action. Minh ThaiJim Henery Executive DirectorDivisionChief Planning andBuilding AgencyOrange County Fire Authority MF:rb mf\\reports\\Building Code Update RFCA 11.19.2019 Exhibits:1. Ordinance California Building Standards Code Amendments 2. Resolution Code Adoption Findings *:1:11-3III i1 LS 11.19.19 ORDINANCE NO. NS-XXXX AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF SANTA ANA AMENDING CHAPTERS 8 AND 14 OF THE SANTA ANA MUNICIPAL CODE TO ADOPT AND AMEND THERETO THE MOST RECENTLY ENACTED CALIFORNIA BUILDING CODE, CALIFORNIA RESIDENTIAL CODE, CALIFORNIA GREEN BUILDING STANDARDS CODE, CALIFORNIA ELECTRICAL CODE, CALIFORNIA MECHANICAL CODE, CALIFORNIA PLUMBING CODE, CALIFORNIA ENERGY CODE, CALIFORNIA FIRE CODE, CALIFORNIA EXISTING BUILDING CODE, AND INTERNATIONAL PROPERTY MAINTENANCE CODE THE CITY COUNCIL OF THE CITY OF SANTA ANA DOES HEREBY ORDAIN AS FOLLOWS: SECTION 1: Section 8-43 of the Santa Ana Municipal Code is hereby amended such that it reads as follows: Sec. 8-43. Adoption by reference. There is adopted by the city that certain code known as the California Building Code, 2016 2019 Edition, based on the 2415 2018 International Building Code as published by the International Code Council, (hereinafter referred to in this article as the "Building Code," "building code," or "California Building Code"), consisting of "Volume 1", "Volume 2" and the 2,0U 2019 California Existing Building Code (together with subsequent supplements or amendments to any volume, each of which shall become effective, adopted, and incorporated by reference into this Code on the date specified by the state building standards commission, unless otherwise specified), of which not less than one (1) copy of said Code has been and is now on file in the office of the clerk of the council of the city pursuant to Health and Safety Code Section 18942(d)(1) and are made available for public inspection. The building code is adopted and incorporated by reference as though fully set forth at length herein as provided for in section 419 of the Charter of the city, except for the changes to the building code set forth in this chapter that specifically amends the Building Code. Any previously enacted, unrepealed provision of the Santa Ana Municipal Code that amended a pre 2016 2019 edition of the "Building Code" shall also be construed as amending the applicable provision of the 2 W 2019 or later edition of the building code. The building code, as thus amended, together with all other provisions of this article, shall be known as the city building code. Appendices which are adopted pursuant to this section are as follows: Appendix I, Patio Covers Ordinance No. NS-XXXX Page 1 of 36 Appendix J, Grading SECTION 2: Section 8-93 of the Santa Ana Municipal Code is hereby amended and added such that it reads as follows: Secs. 8-92—,8-93. - Reserved. Sec. 8-93. Permit expiration (Volume 1, Chapter 1, Division II, Section 105.5). Chapter 1, Division II, Section 105.5 of the building code is amended to read as a follows: Sec. 105.5 Expiration. Every permit issued shall become invalid unless the work on the site authorized by such permit is commenced within 12 months after its issuance, or if the work authorized on the site by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. The building official is authorized to grant in writing, one or more extensions of time for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. SECTION 3: Section 8-85 of the Santa Ana Municipal Code is hereby added such that it reads as follows: Chapter 5, Section 506.4.3 of the California Existing Building Code is amended by adding the following paragraph thereto: The conversion of any portion of an existing building to residential use shall be analyzed for 75 percent of the Design Earthquake Ground motion, as defined in Section 1613.2 of the California Building Code, but in no event shall there be a reduction in the capacity of the seismic force resisting system where such system provides a greater level of protection than the minimum requirements established by this code. Performance - based engineering analysis and design procedures may be used to evaluate the existing structure and the design of strengthening elements when approved by the Building Official. All new structural elements shall meet current detailing requirements of Section 1604 of the California Building Code. Ordinance No. NS-XXXX Page 2 of 36 SECTION 4: Section 8-290 of the Santa Ana Municipal Code is hereby amended such that it reads as follows: Sec. 8-290. Adoption by reference. There is adopted by the city that certain code known as the California Plumbing Code, 2016 2019 Edition, including the following appendices thereto: A, B, D, I and J, (hereinafter referred to in this article as the "Plumbing Code"), together with subsequent supplements or amendments, which shall become effective, adopted and incorporated by reference into this Code on the date specified by the state building standards commission, unless otherwise specified. The plumbing code is adopted and incorporated by reference as fully set forth at length herein as provided for in section 419 of the Charter of the city, except for the changes to the plumbing code set forth in this chapter of this Code that specifically amend the plumbing code. Any previously enacted, unrepealed provision of this Code that amended a pre-2816 2019 edition of the "Plumbing Code" shall also be construed as amending the applicable provision of the 201-6 2019 or later edition of the plumbing code. The plumbing code as amended, together with all other provisions of this article, shall be known as the city plumbing code. SECTION 5: Section 8-340 of the Santa Ana Municipal Code is hereby amended such that it reads as follows: Sec. 8-340. Underground Installation (California Plumbing Code Section 313.5). Section 313.5 of the Plumbing Code is amended to read as follows: 313.5. Underground Installation. Piping in the ground shall be laid on a firm bed for its entire length. Building drains, sewers and storm drain piping systems in the ground, and designed and approved at less than one (1) percent grade, shall be laid on a continuous firm bed, certified by a registered soils engineer as having a compaction level of not less than ninety (90) percent density. Where support is otherwise provided, it shall be approved per Section 301.2 of this code. SECTION 6: Section 8-556 of the Santa Ana Municipal Code is hereby amended such that it reads as follows: Sec. 8-556. Adoption by reference. There is adopted by the city that certain code known as the California Mechanical Code, 2016 2019 edition (hereinafter referred to in this article as the "California Mechanical Code" "Mechanical Code" or "mechanical code"), together with subsequent supplements, amendments, or editions, which shall become effective, adopted, and incorporated by reference into this Code on the date specified by the state building standards commission, unless otherwise specified. The mechanical code is adopted Ordinance No. NS-XXXX Page 3 of 36 and incorporated by reference as though fully set forth at length herein as provided for in section 419 of the Charter of the city, except for the changes to the mechanical code set forth in this chapter of this Code that specifically amend the mechanical code. Any previously enacted, unrepealed provision of this Code that amended a pre 2016 2019 edition of the "Mechanical Code" shall also be construed as amending the applicable provision of the 204-6 2019 or later edition of the mechanical code. The mechanical code as amended, together with all other provisions of this article, shall be known as the city mechanical code. SECTION 7: Section 8-570 of the Santa Ana Municipal Code is hereby removed in its entirety. - - .. ' - fAILNI!I -. � . mDAIIIIIIIIIIIIII rr-MvIrr... Z Ordinance No. NS-XXXX Page 4 of 36 271111 „- - - -Sec. 8-570. Reserved. SECTION 8: Section 8-667 of the Santa Ana Municipal Code is hereby amended such that it reads as follows: Sec. 8-667. Adoption by reference. There is adopted by the city that certain code known as the California Electrical Code 2016 2019 Edition and the administrative provisions set forth herein, (hereinafter referred to in this article as the "Electrical Code") together with subsequent supplements, amendments, or editions, which shall become effective, adopted, and incorporated by reference into this Code on the date specified by the state building standards commission, unless specifically adopted prior to that date, of which not less than one (1) copy of said Code has been and is now on file in the office of the clerk of the council of the city pursuant to Health and Safety Code Section 18942(d)(1) and are made available for public inspection. The electrical code is adopted and incorporated by reference as though fully set forth at length herein as provided for in section 419 of the Charter of the city, except for the changes to the electrical code set forth in this chapter of this code that specifically amend the electrical code. Any previously enacted, unrepealed provision of this Code that amended a pre 201-6 2019 edition of the "Electrical Code" shall also be construed as amending the applicable provision of the 2016 2019 or later edition of the electrical code. The electrical code as amended, together with all other provisions of this article, shall be known as the city electrical code. Annex which are adopted pursuant to this section are as follows: Informative Annex A, Product Safety Standards SECTION 9: The City Council of the City of Santa Ana hereby finds, determines and declares that adoption of section 8-942 amending California Electrical Code Section 334.12 is necessary because earthquakes are a common occurrence in the local area; Ordinance No. NS-XXXX Page 5 of 36 that, unlike wire installed in conduit or raceways, non-metallic sheathed cable does not provide the degree of protection that is needed in the event of an earthquake; that exposed non-metallic sheathed cable is particularly hazardous; and that this amendment is necessary to assure that adequate protection is provided in the workplace and in other places of public gathering. SECTION 10: Section 8-2000 of the Santa Ana Municipal Code is hereby amended such that it reads as follows: Sec. 8-2000. Adoption by reference. There is adopted by the city that certain code known as the 2016 2018 International Property Maintenance Code (hereinafter referred to as the "Property Maintenance Code"), together with subsequent supplements, amendments, or editions, which shall become effective, adopted, and incorporated by reference into this Code on each new official publication date of the International Property Maintenance Code, of which not less than one (1) copy of said Code has been and is now on file in the office of the clerk of the council of the city pursuant to Health and Safety Code Section 18942(d)(1) and are made available for public inspection. The said Code is adopted and incorporated as fully as if set forth at length herein as provided for in section 419 of the Charter of the city, except for the changes to the property maintenance code set forth in this chapter of this Code that specifically amends the property maintenance code. Any previously enacted, unrepealed provision of this Code that amended a pre 2015 2018 edition of the 'Property Maintenance Code" shall also be construed as amending the applicable provision of the 2016 2018 or later edition of the property maintenance code. The property maintenance code, as thus amended, together with all other provisions of this article, shall be known as the city property maintenance code. SECTION 11. Section 8-2800 is added to Chapter 8 of the Santa Ana Municipal code to read in full as follows: Sec. 8-2800. Adoption by reference. There is adopted by the city that certain code known as the California Residential Code, 2016 2019 Edition, based on the 2045 2018 International Residential Code as published by the International Code Council, (hereinafter referred to in this article as the "Residential Code" or "California Residential Code"), (together with subsequent supplements or amendments shall become effective, adopted, and incorporated by reference into this Code on the date specified by the state building standards commission, unless otherwise specified), of which not less than one (1) copy of said Code has been and is now on file in the office of the Clerk of the Council of the city pursuant to Health and Safety Code Section 18942(d)(1) and are made available for public inspection. The Residential code is adopted and incorporated by reference as though fully set forth at length herein as provided for in section 419 of the Charter of the city, except for the changes to the Residential code set forth in this chapter that specifically amends the Residential Code. The Residential code, as thus amended, Ordinance No. NS-XXXX Page 6 of 36 together with all other provisions of this article, shall be known as the city Residential code. Appendices which are adopted pursuant to this section, are as follows: Appendix H, Patio Covers Appendix J, Existing Buildings and Structures SECTION 12: Section 8-2810 of the Santa Ana Municipal Code is hereby amended such that it reads as follows: Sec. 8-2810. Climatic and Geographic Design Criteria (Table R301.2(1)). Table R301.2(1) is revised to read: TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA GROUND SNOW LOAD WIND DESIGN SEISMIC DESIGN CATEGORY ' SUBJECT TO DAMAGE FROM WINTER DESIGN TEMP- ICE BARRIER UNDERLAY- MENT REQUIREDh FLOOD HAZARDS a AIR FREEZING INDEXi MEAN ANNUAL TEMPI Speed d mph) Topo- graphic effects" Special indborn Weathering L12-24"He2v wind debris zone- re ion' Zero 110 No No No Ds or E Ne II ible Al No See Exhibit B 0 60 For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s. a. Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code. The weathering column shall be filled in with the weathering index (i.e., "negligible," "moderate" or "severe") for concrete as determined from the Weathering Probability Map [Figure R301.2(3)]. The grade of masonry units shall be determined from ASTM C 34, C 55, C 62, C 73, C 90, C 129, C 145, C 216 or C 652. b. The frost line depth may require deeper footings than indicated in Figure R403.1(1). The jurisdiction shall fill in the frost line depth column with the minimum depth of footing below finish grade. C. The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. Cl. The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map [Figure R301.2(A)].Wind exposure category shall be determined on a site -specific basis in accordance with Section R301.2.1.4. Ordinance No. NS-XXXX Page 7 of 36 e. Temperatures shall be permitted to reflect local climates or local weather experience as determined by the building official. f. The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. g. The jurisdiction shall fill in this part of the table with (a) the date of the jurisdiction's entry into the National Flood Insurance Program (date of adoption of the first code or ordinance for management of flood hazard areas), (b) the date(s) of the Flood Insurance Study and (c) the panel numbers and dates of all currently effective FIRMS and FBFMs or other flood hazard map adopted by the authority having jurisdiction, as amended. h. In accordance with Sections R905.2.7.1, R905.4.3.1, R905.5.3.1, R905.6.3.1, R905.7.3.1 and R905.8.3.1, where there has been a history of local damage from the effects of ice damming, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall fill in this part of the table with "NO." i. The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index (BF -days) from Figure R403.3(2) or from the 100-year (99%) value on the National Climatic Data Center data table "Air Freezing Index- USA Method (Base 32°)" at www.ncdc.noaa.gov/fpsf.htrnl. j. The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table "Air Freezing Index -USA Method (Base 32°F)" at www.ncdc.noaa.gov/fpsf.html. k. In accordance with Section R301.2.1.5, where there is local historical data documenting structural damage to buildings due to topographic wind speed-up effects, the jurisdiction shall fill in this part of the table with "YES." Otherwise, the jurisdiction shall indicate "NO" in this part of the table. SECTION 13. Section 8-2900 of the Santa Ana Municipal Code is hereby amended such that it reads as follows: Sec. 8-2900. Adoption by reference. There is adopted by the city that certain code known as the California Green Building Standards Code, 2046 2019 Edition, as published by the International Code Council, (hereinafter referred to in this article as the "California Green Building Standards Code"), (effective, adopted, and incorporated by reference into this Code on Ordinance No. NS-XXXX Page 8 of 36 the date specified by the state building standards commission, unless otherwise specified), of which not less than one (1) copy of said Code has been and is now on file in the office of the clerk of the council of the city pursuant to Health and Safety Code Section 18942(d)(1) and are made available for public inspection. The Green Building Standards code is adopted and incorporated by reference as though fully set forth at length herein as provided for in section 419 of the Charter of the city. The California Green Building Standards code, as thus amended, together with all other provisions of this article, shall be known as the city Green Building Standards code. SECTION 14: Section 8-3000 of the Santa Ana Municipal Code is hereby added such that it reads as follows: Sec. 8-3000. Adoption by reference. There is adopted by the city that certain code known as the California Energv Code, 2019 Edition, as published by the International Code Council, (hereinafter referred to in this article as the "California Energy Code'), (effective, adopted, and incorporated by reference into this Code on the date specified by the state buildinq standards commission, unless otherwise specified), of which not less than one (1) copy of said Code has been and is now on file in the office of the clerk of the council of the city pursuant to Health and Safetv Code Section 18942(d)(1) and are made available for public inspection. The California Energy Code is adopted and incorporated by reference as though fully set forth at length herein as provided for in section 419 of the Charter of the city. The California Energy Code, as thus amended, together with all other provisions of this article, shall be known as the city Energy code. SECTION 15: Section 14-1 of the Santa Ana Municipal Code is hereby amended such that it reads as follows: Sec. 14-1. Adoption by reference. There is adopted by the city that certain code known as the California Fire Code 2448 2019 Edition, based on the 2015 2018 International Fire Code as published by the International Code Council, (hereinafter referred to in this article as the "California Fire Code' or "fire code") and the whole thereof including the Appendices therein, errata issued during and after the publishing date, save and except such portions as are hereinafter deleted or amended, of which code not less than one (1) copy has been and is now on file in the office of the clerk of the council of the city pursuant to Health and Safety Code Section 18942(d)(1) and are made available for public inspection. Said code is adopted and incorporated as fully as if set forth at length herein and, subject to all amendments set forth in this article, shall be in effect within the city from the effective date of this article. Any provision of this article amending the above mentioned codes shall be construed as amending the 2015 2018 and 2OU 2019 editions thereof including such provisions enacted prior to this adoption of the said 2015 2018 and 2-OU 2019 editions and not thereafter repealed. The International Fire Code, 2015 2018 Ordinance No. NS-XXXX Page 9 of 36 edition and the California Fire Code 241-6 2019 edition, as thus amended, together with all other provisions of this article, shall be known as the "Fire Code of the City of Santa Ana." SECTION 16: Section 14-3.1 is hereby amended and revised as follows: Sec. 14-3.1. - Violation penalties (Section 109 4 110.4). Section 109 4 110.4 Violation penalties. 110.4 Violation penalties. Persons who shall violate a provision of this code or shall fail to comply with any of the requirements thereof or shall fail to comply with any issued orders or notices or who shall erect, install, alter, repair or do work in violation of the approved construction documents or directive of the fire code official, or of a permit or certificate used under provisions of this code, shall be subject to penalties assessed as prescribed in the OCFA Prevention Field Services adopted fee schedule. Each day that a violation continues after due notice has been served shall be deemed a separate offense. (a) Section 109.4.2110.4.2 Infraction and misdemeanor is hereby added as follows: 1013 42110.4.2 Infraction and misdemeanor. Persons operating or maintaining any occupancy, premises or vehicle subject to this code that shall permit any fire or life safety hazard to exist on premises under their control shall be guilty of an infraction. Persons who fail to take immediate action to abate a fire or life safety hazard when ordered or notified to do so by the chief or a duly authorized representative are guilty of a misdemeanor. Secs.14-4-14-9. Reserved. SECTION 17: Section 14-21 is hereby amended as follows: Sec. 14-21. - Definitions (Section 202). Ordinance No. NS-XXXX Page 10 of 36 Chapter 2 Definitions is adopted in its entirety with the following amendment: Section 202 General Definitions is hereby revised by adding "OCFA," sky ' a and "Spark Arrester" as follows: 202 General Definitions OCFA- Orange County Fire Authority, fire authority having jurisdiction. Wall N*W SPARK ARRESTER- A listed device constructed of noncombustible material specifically for the purpose of meeting one of the following conditions: Removing and retaining carbon and other flammable particles/debris from the exhaust flow of an internal combustion engine in accordance with California Vehicle Code Section 38366. Fireplaces that burn solid fuel in accordance with California Building Code Chapter 28. SECTION 18: Section 14-22 is hereby amended as follows: Sec. 14-22. - General requirements (Chapter 3). Chapter 3 General Requirements. Adopt Chapter 3 in its entirety, with the exception of Sections 308.1.4, 311.5 through 311.5.5, 318, and 319, and with the following amendments: (a) Section 0, .1.2 Vegetation. Type, arneuRt, 9F aFraRgernent of weeds, grass, Vines OGGUpant of the pmn.s in accordance with OCFA Guideline G 05 WegetatieR ._ Weeds, arass. vines or other arowth that is capable of beina ianited and endangering property, shall be cut down and removed by the owner or occupant of the premises. Vegetation clearance requirement in urban-wildland interface areas shall be in accordance with Chapter 49. Type, amount, arrangement, and maintenance of vegetation in a fuel modification area, interior slope, or similarly hazardous area shall be in accordance with OCFA Guideline C-05 "Vegetation Manaaement Guideline —Technical Desian for New Construction. Fuel Modification Plans, and Maintenance Program." Ordinance No. NS-XXXX Page 11 of 36 (b) Section 305.6 Hazardous Conditions is hereby amended as follows: Hazardous305.6 Outdoor fires burning wood or other solid fuel are not allowed when any of the following conditions applies: 1. when predicted sustained winds exceed 8 MPH and relative humidity is less than 25%, or a red flag condition has been declared 2. when an official sign was caused to be posted by the fire code official, or a public announcement is made No outdoor fires using any fuel type are permitted when predicted sustained winds exceed 20 MPH or when such fires present a hazard as determined by the fire code official. (c) Section 305.7 Disposal of rubbish is hereby added as follows: 305.7 Disposal of rubbish. Rubbish, trash or combustible waste material shall be burned only within an approved incinerator and in accordance with Section 307.2.1. (d) Section 307 OPEN BURNING, RECREATIONAL FIRES AND PORTABLE OUTDOOR FIREPLACES is hereby revised as follows: SECTION 307 OPEN BURNING, RECREATIONAL FIRES, FIRE PITS, FIRE RINGS, AND PORTABLE OUTDOOR FIREPLACES Section 307 307.6 Outdoor Fireplaces, fire Pits, Fire Rings, or similar devices used at Group R Occupancies is hereby added as follows: 307.6 Outdoor Fireplaces, Fire Pits, Fire Rings, or similar devices used at Group R Occupancies. Outdoor fireplaces, fire pits, fire rings, or similar exterior devices used at Group R shall comply with this section. Exception: Barbeques, grills, and other portable devices intended solely for cooking. 307.6.1 Gas -fueled devices. Outdoor fireplaces, fire pits and similar devices fueled by natural gas or liquefied -petroleum gas are allowed when approved by the Building Department and the device is designed to only burn a gas flame and not wood or other solid fuel. At R-3 occupancies, combustible construction Ordinance No. NS-XXXX Page 12 of 36 shall not be located within three feet of an atmospheric column that extends vertically from the perimeter of the device. At other R occupancies, the minimum distance shall be ten feet. Where a permanent Building Department approved hood and vent is installed, combustible construction may encroach upon this column between the bottom of the hood and the vent opening. Where chimneys or vents are installed, they shall have a spark arrester as defined in Section 202. Section 307.6.2 Devices using wood or fuels other than natural gas or liquefied -petroleum gas is hereby amended as follows: 307.6.2 Devices usina wood or fuels other than natural aas or liauefied- . • nnra„11. _ ME Permanent outdoor fireplaces burning wood or other solid fuel shall be constructed in accordance with the California Building Code with clearance from combustible construction and building openings as required therein. Fires in a fireplace shall be contained within a firebox with an attached chimney. The opening in the face of the firebox shall have an installed and maintained method of arresting sparks. The burning of wood or other solid fuel in a device is not allowed within 25 feet of combustible structures, unless within an approved permanent fireplace. Conditions which could cause a fire to spread within 25 feet of a structure or to vegetation shall be eliminated prior to ignition. Fires in devices burning wood or solid fuel shall be in accordance with Sections 305, 307, and 308. Exceptions: 1. Portable fireplaces and fire rings/pits equipped with a device to arrest sparks shall be located at least 3' from combustible construction at R-3 occupancies, 2. Portable fireplaces, and fire pits/rings equipped with a device to arrest sparks shall be located at least 15 feet from combustible structures at other R occupancies. Section 307.6.2.1 Where prohibited is hereby amended as follows: Ordinance No. NS-XXXX Page 13 of 36 The burning of wood and other solid fuels shall not be conducted within a fuel modification zone, Wildfire Risk Area (WRA), Wildland-Urban Interface Area (WUI), or in locations where conditions could cause the spread of fire to the WRA or WUI. Exceptions: 1. Permanent fireplaces that are not located in a fuel modification zone 2. Where determined by the Fire Code Official that the location or design of the device should reasonably prevent the start of a wildfire. (e) Section 308.1.6.3 Sky lanterns is hereby revised as follows: 308.1.6.3 Sky lanterns. A person shall not ignite, release, or cause to be released aq untet, cth`red sky lantern. (f) Section 309,21 309.3.1 Indoor charging of electric carts/cars is hereby removed. (g) Section 320 321 Fuel Modification Requirements for New Construction is hereby amended as follows: 320 321 Fuel Modification Requirements for New Construction. All new structures and facilities adjoining land containing hazardous combustible vegetation shall be approved and in accordance with the requirements of OCFA Guideline C- 05 "Vegetation Management Guideline — Technical Design for New Construction Fuel Modification Plans and Maintenance Program." Ordinance No. NS-XXXX Page 14 of 36 (h) Section 324 322 Clearance of brush or vegetation growth from roadways is hereby amended as follows: 324 322 Clearance of brush or vegetation growth from roadways. The fire code official is authorized to cause areas within 10 feet (3048 mm) on each side of portions of highways and private streets which are improved, designed or ordinarily used for vehicular traffic, to be cleared of flammable vegetation and other combustible growth. Measurement shall be from the flow -line or the end of the improved edge of the roadway surfaces. Exception: Single specimens of trees, ornamental shrubbery or cultivated ground cover such as green grass, ivy, succulents or similar plants used as ground covers, provided that they do not form a means of readily transmitting fire. (i) Section 322 323 Unusual Circumstances is hereby amended as follows: 322 323 Unusual circumstances. The fire code official may suspend enforcement of the vegetation management requirements and require reasonable alternative measures designed to advance the purpose of this code if determined that in any specific case that any of the following conditions exist: 1. Difficult terrain. 2. Danger of erosion. 3. Presence of plants included in any state and federal resources agencies, California Native Plant Society and county -approved list of wildlife, plants, rare, endangered and/or threatened species. 4. Stands or groves of trees or heritage trees. 5. Other unusual circumstances that make strict compliance with the clearance of vegetation provisions undesirable or impractical. (j) Section 323 324 Use of Equipment is hereby added as follows: 323 324 Use of equipment. Except as otherwise provided in this section, no person shall use, operate, or cause to be operated in, upon or adjoining any hazardous fire area any internal combustion engine which uses hydrocarbon fuels, unless the engine is equipped with a spark arrester as defined in Section 202 maintained in effective working order, or the engine is constructed, equipped and maintained for the prevention of fire. Exception: 1. Engines used to provide motor power for trucks, truck tractors, buses, and passenger vehicles, except motorcycles, are not subject to this section if the exhaust system is equipped with a muffler as defined in the Vehicle Code of the State of California. Ordinance No. NS-XXXX Page 15 of 36 2. Turbocharged engines are not subject to this section if all exhausted gases pass through the rotating turbine wheel, there is no exhaust bypass to the atmosphere, and the turbocharger is in good mechanical condition. (k) Section 323 1 324.1 Use of Equipment and Devices Generating Heat, Sparks or Open Flames is hereby amended as follows: 323.1 324.1 Equipment and devices generating heat, sparks or open flames. During any time of the year within Wildfire Risk Areas, within or immediately adjacent to any forest- or brush -covered land or non -irrigated grass -covered land, no person shall use or operate any welding equipment, cutting torches, tar pots, grinding devices, or other tools or equipment that may produce a spark, fire, or flame that could result in a wildfire without doing the following: 1. First clearing away all flammable material, including snags, from the area around such operation for a distance of 30 feet or other approved method to reduce fire spread into the wildlands. If 30 foot clearing cannot be achieved then an alternate method shall be approved by the AHJ prior to work starting. 2. Maintain one serviceable round point shovel with an overall length of not less than forty-six (46) inches and one backpack pump water -type fire extinguisher fully equipped and ready for use at the immediate area during the operation. 3. Stop work when winds are 8 MPH during periods when relative humidity is less than 25%, or a red flag condition has been declared or public announcement is made, when an official sign was caused to be posted by the fire code official, or when such fires present a hazard as determined by the fire code official. 4. Keep a cell phone nearby and call 911 immediately in case of a fire. (1) Section 323 2 324.2 Spark Arresters is hereby added as follows: 3232 324.2 Spark arresters. Spark arresters shall comply with Section 202, and when affixed to the exhaust system of engines or vehicles subject to Section 323 324 shall not be placed or mounted in such a manner as to allow flames or heat from the exhaust system to ignite any flammable material. SECTION 19: Section 14-23 is hereby amended as follows: Sec. 14-23. - Emergency planning and preparedness (Chapter 4). Chapter 4: Emergency Planning and Preparedness. Only the following Sections listed below are adopted: Ordinance No. NS-XXXX Page 16 of 36 2 401.3.4 3. 401.0 4. 402 5. 403 7. 407 1. 401 — 401.9 2. 402 3. 403.2 4. 403.5 — 403.5.4 5. 403.10.2.1.1 6. 403.13 — 403.13.3 7. 404.5 — 404.6.6 8. 407 SECTION 20: Section 14-24 is hereby amended as follows Sec. 14-24. - Fire service features (Chapter 5). Chapter 5 Fire Service Features is adopted in its entirety with the following amendments: (a) SECTION 501.1 Scope is revised to read as follows: Fire service features for buildings. structures and Dremises shall comply with this chapter and, where required by the fire code official, with OCFA Guideline B-09, "Fire Master Plan for Commercial & Residential Development." Fire service features for buildings, structures and premises located in State Responsibility Areas, and Local Responsibility Areas designated as Very High Hazard Fire Severity Zone shall also comply with OCFA Guideline B-09a, "Fire Safe Development in State Responsibility Areas, and Local Responsibility Areas designated as Very High Hazard Fire Severity Zone". (b) Section 505.1 Address Identification is revised as follows Ordinance No. NS-XXXX Page 17 of 36 505.1 Address identification. New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Where required by the fire code official, address numbers shall be provided in additional approved locations to facilitate emergency response. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall be a minimum of 4 inches (101.6 mm) high with a minimum stroke width of 0.5 inch (12.7 mm) for R-3 occupancies, for all other occupancies the numbers shall be a minimum of 6 inches high with a minimum stroke width of 1 inch. Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address numbers shall be maintained. (c) Section 510.1 Emergency responder radio coverage in new buildings is revised to read as follows: 510.1 Emergency responder radio coverage in new buildings. All new buildings shall have approved radio coverage for emergency responders within the building based upon the existing coverage levels of the public safety communication systems of the utilized by the jurisdiction measured at the exterior of the building. This section shall not require improvement of the existing public safety communication systems. The Emergency Responder Radio Coverage System shall comply with the Orange County Sheriff's Department, Communications and Technology Division guidelines and specifications and, where the functionality or performance requirements in the California Fire Code are more stringent, this code. Exceptions: rWarn IIIIIIIU rim Ordinance No. NS-XXXX Page 18 of 36 3. Strusta;es that arethree Stories OF less without subte, raneaR sterage e paFkiRg and that do not exceed 50,000 squaF8 feet on any single stefy-. 4. Weed wastwcted residentai Structures fouste; eS eF less i.A.futheut subterranean storage o aPkinn that a not h 'It integral to an above pro, end multi stery parkin str n4 r e. 5. Qheuld n nstr ot'on that 's three stories or loos that does not exceed 50,000 squaFe foot OR aRy SiRgle Sten, 'n..lu de subterranean storage n narking then this ontinanse hall apply only to the subterranean areas. In buildings or structures where it is determined by the fire code official that the radio coverage system is not needed, including but not limited to the following: a. Existinq buildings or structures, unless required by the Building Official and OCFA for buildings and structures undergoing extensive remodel and/or expansion. b. Elevators. c. Structures that meet all of the following: i. Three stories or less, and ii. Do not have subterranean storage or parking, and iii. Do not exceed 50,000 square feet on any single story. d. Structures that meet all of the following: i. Residential structures four stories or less, and ii. Constructed of wood, and iii. Do not have subterranean storage or parking, and iv. Are not built integral to an above ground multi -story parking structure. Should a structure that is three stories or less and 50,000 square feet or smaller on any single story include subterranean storage or parking then this ordinance shall apply only to the subterranean areas. 2. In facilities where emeraencv responder radio coveraae is reauired and such systems, components or equipment required could have a negative impact on the normal operations of the facility, the fire code official shall have the authoritv to accept an automaticallv activated emeraencv radio coverage system (d) Section 510.2 Emergency responder radio coverage in existing buildings is deleted without replacement. (e) Section 510.3 Permit required is deleted without replacement. (ef) Section 510.4.2.2 Technical Criteria is revised to read as follows: adopted without amendment. Ordinance No. NS-XXXX Page 19 of 36 (fg) Section 510.5.1 Approval prior to installation is adopted without amendment.. (9h) Section 510.5.2 Minimum qualification of personnel is removed without replacement. system designer and lead installation per-sGnnel shall 'RGlude beth ef the fellc)WiRg� 1. A valid F=CG issued general radio operator's license. 2. GeFtiftat'Gn of in building system training issued by a Patienally F8GGgRized Ordinance No. NS-XXXX Page 20 of 36 without 1 GGverage system is required, and upon completion of installatieR, the buildiRg GWRGF shall have the Fadwo system tested to- ens-w-m- that tv.re- Way GOVeFagele m manh finor of the building us RGt less thaR •• - 91-�T-T37 ■ ml• 1 adopted without We Will Z __ ■ • ■ Ordinance No. NS-XXXX Page 21 of 36 SECTION 21: Section 14-30 is hereby amended to read as follows: Sec. 14-30. - Fire protection and Life Safety Systems (Chapter 9). Chapter 9 Fire protection and Life Safety Systems is adopted in its entirety with the following amendments: (a) Section 903.2 Where required is hereby amended as follows: 903.2 Where required. Approved automatic sprinkler systems in buildings and structures shall be provided when one of the following conditions exists: 1. New buildings: Notwithstanding any applicable provisions of Sections 903.2.1 through 903.2.19, an automatic fire -extinguishing system shall also be installed in all occupancies when the total building area exceeds 5,000 square feet (465 m2) as defined in Section 202, regardless of fire areas or allowable area, or is more than two stories in height. Exception: Subject to approval by the Fire Code Official, open parking garages in accordance with Section 406.5 of the California Building Code. 2. Existing Buildings: Notwithstanding any applicable provisions of this code, an automatic sprinkler system shall be provided in an existing building when an addition occurs and one of the following conditions exists: a. When an addition is 33% or more of the existing building area, and the resulting building area exceeds 5000 square feet (465 m2) as defined in Section 202; or b. When an addition exceeds 2000 square feet (186 m2) and the resulting building area exceeds 5000 square feet (465 m2) as defined in Section 202; or c. An additional story is added above the second floor regardless of fire areas or allowable area. Exception: Group R-3 occupancies shall comply with Section 903.2.8. (b) Section 903.3.5.3 Hydraulically calculated systems is hereby added as follows: 903.3.5.3 Hydraulically calculated systems. The design of hydraulically calculated fire sprinkler systems shall not exceed 90% of the water supply capacity Exception: When static pressure exceeds 100 psi, and required by the Fire Code Official, the fire sprinkler system shall not exceed water supply capacity specified by Table 903.3.5.3 Ordinance No. NS-XXXX Page 22 of 36 SECTION 22: Section 14-31 is hereby amended and added to read as follows: Sec. 14-31. — Energy Systems (Chapter 12). Chapter 12 Energy Systems is adopted in its entirety with the following amendments added: 1201.1.1 Other Systems Where required by the fire code official, other systems and operations including but not limited to battery systems assembly, battery reconditioning and storage, research and development of battery storage systems, electric vehicle manufacturing and testing and battery charging systems for cars and carts inside of buildings or structures, shall comply with this chapter. SECTION 23: Section 14-32 is hereby amended to read as follows: Sec. 14-32. — Construction requirements for Existing Buildings (Chapter 11). Chapter 11 Construction Requirements for Existing Buildings: Only the following Sections and Subsections are adopted: 1103.7 1103.7.3 1103.7.3.1 1103.7.8 — 1103.7.8.2 1103.7.9 — 1103.7.9.10 1103.8 — 1103.8.5.3 1103.9.1 1107 1113 1114 1115 1116 SECTION 24: Section 14-33 is hereby removed as follows: Ayintann Farmlit0es (Chapter ten` Sec. 14-33. RESERVED. SECTION 25: Section14-34 is hereby amended to read as follows: Sec. 14-34. - Lumber Yards and Agro-Industrial, Solid Biomass and Woodworking Facilities (Chapter 28). Ordinance No. NS-XXXX Page 24 of 36 Chapter 28 Lumber Yards and Agro-Industrial. Solid Biomass and Woodworking Facilities is adopted in its entirety with the following amendments: (a) Section 2801.2 Permit is hereby amended ; adding the fe!!e ing stateMert ,e the lasts sentence revised as follows: 2801.2 Permit. Permits shall be required as set forth in Section 105.6. €er M'SGe"aReGUS Ge^ b st;b!e Stwaap Pe.^ gee Seetie^ and 105.6.29. (b) Section 2808.2 Storage site is hereby amended revised as follows 2808.2 Storage site. Storage sites shall be level and on solid ground, elevated soil lifts or other all-weather surface. Sites shall be thoroughly cleaned and approval obtained from the fire code official obtained before transferring products to the site. (c) Section 2808.3 Size of piles is hereby amendpd revised as follows: 2808.3 Size of piles. Piles shall not exceed 15 feet (457FnrR) in height, 50 feet 45 '^� in width and 100 feet (30-480-mm) in length. Exception: The fire code official is authorized to allow the pile size to be increased where a fire protection plan is provided for approval that includes, but is not limited to, the following: 1. Storage yard areas and materials -handling equipment selection, design and arrangement shall be based upon sound fire prevention and protection principles. 2. Factors that lead to spontaneous heating shall be identified in the plan, and control of the various factors shall be identified and implemented, including provisions for monitoring the internal condition of the pile. 3. The plan shall include means for early fire detection and reporting to the public fire department; and facilities needed by the fire department for fire extinguishment including a water supply and fire hydrants. 4. Fire apparatus access roads around the piles and access roads to the top of the piles shall be established, identified and maintained. 5. Regular yard inspections by trained personnel shall be included as part of an effective fire prevention maintenance program. Additional fire protection called for in the plan shall be provided and shall be installed in accordance with this code. The increase of the pile size shall be based upon the capabilities of the installed fire protection system and features. (d) Section 2808.4 Pile Separation is hereby added as follows: Ordinance No. NS-XXXX Page 25 of 36 2808.4. Pile separation. Piles shall be separated from adjacent piles by -a minimum distance of 20 feet. Additionally, piles shall have a minimum separation of 100 feet from combustible vegetation. (ee) Section 2808.7 Pile fire protection is hereby revised as follows: 2808.7 Pile fire protection. Automatic sprinkler protection shall be provided in conveyor tunnels and combustible enclosures that pass under a pile. Combustible conveyor systems and enclosed conveyor systems shall be equipped with an approved automatic sprinkler system. Oscillating sprinklers with a sufficient projectile reach are required to maintain a 40% to 60% moisture content and wet down burning/smoldering areas. (fg) Section 2808.9 Material -handling equipment, is hereby revised as follows: 2808.9 Material -handling equipment. All material handling equipment operated by an internal combustion engine shall be provided and maintained with an approved spark arrester. Approved material -handling equipment shall be available for moving wood chips, hogged material, wood fines and raw product during fire -fighting operations. (gh)Section 2808.11 Temperature control, is hereby added as follows: 2808.11 Temperature control. The temperature shall be monitored and maintained as specified in Sections 2808.11.1 and 2808.11.2. (hi) Section 2808.11.1 Pile temperature control, is hereby added as follows: 2808.11.1 Pile temperature control. Piles shall be rotated when the internal temperature readings are in excess of 165 degrees Fahrenheit. (ij) Section 2808.11.2 New material temperature control, is hereby added as follows: 2808.11.2 New material temperature control. New loads delivered to the facility shall be inspected and tested at the facility entry prior to taking delivery. Material with temperature exceeding 165 degrees Fahrenheit shall not be accepted on the site. New loads shall be monitored to verify that the temperature remains stable. (jk) Section 2808.12 Water availability is hereby added as follows: 2808.12 Water Availability. Facilities with over 2500 cubic feet shall provide a water supply. The minimum fire flow shall be no less than 500 GPM @ 20 psi for a minimum of 1 hour duration for pile heights up to 6 feet and 2 hour duration for pile heights over 6 feet. If there is no water purveyor, an alternate water supply with storage tank(s) shall be provided for fire suppression. The water supply tank(s) shall provide a minimum capacity of 2500 gallons per pile (maximum 30,000 gallons) for piles not exceeding 6 feet in height and 5000 gallons per pile (maximum 60,000) for piles exceeding 6 feet in height. Water tank(s) shall not be used for any other purpose unless the required fire flow is left in reserve within the tank at all times. An Ordinance No. NS-XXXX Page 26 of 36 approved method shall be provided to maintain the required amount of water within the tank(s). (kl) Section 2808.13 Tipping area is hereby added as follows: 2808.13 Tipping areas shall comply with the following: 1. Tipping areas shall not exceed a maximum area of 50 feet by 50 feet. 2. Material within a tipping area shall not exceed 5 feet in height at any time. 3. Tipping areas shall be separated from all piles by a 20 foot wide fire access lane. 4. A fire hydrant or approved fire water supply outlet shall be located within 150 feet of all points along the perimeter of the tipping area. 5. All material within a tipping area shall be processed within 5 days of receipt. (tm)Section 2808.14 Emergency Contact is hereby added as follows: 2808.14 Emergency Contact. The contact information of a responsible person or persons shall be provided to the Fire Department and shall be posted at the entrance to the facility for responding units. The responsible party should be available to respond to the business in emergency situations SECTION 26: Section 14-35 is hereby added to read as follows: Chapter 49 Requirements for Wildland-Urban Interface Fire Areas Chapter 49 Requirements for Wildland-Urban Interface Fire Areas is adopted in its entirety with the following amendments: Section 4906.3 Requirements is hereby revised as follows: 4906.3 Requirements. Hazardous vegetation and fuels around all applicable buildings and structure shall be maintained in accordance with the following laws and regulations: 1. Public Resources Code, Section 4291. 2. California Code of Regulations, Title 14, Division 1.5, Chapter 7, Subchapter 3, Section 1299 (see guidance for implementation "General Guideline to Create Defensible Space"). 3. California Government Code, Section 51182. Ordinance No. NS-XXXX Page 27 of 36 4. California Code of Regulations, Title 19, Division 1 Chapter 7, Subchapter 1, Section 3.07. 5. OCFA Guideline C-05 "Vegetation Management Guideline — Technical Design for New Construction Fuel Modification Plans and Maintenance Program." Section 4908 Fuel Modification Requirements for New Construction is hereby added as follows: 4908 Fuel Modification Requirements for New Construction. All new buildings to be built or installed in a Wildfire Risk Area shall comply with the following: 1. Preliminary fuel modification plans shall be submitted to and approved by the fire code official prior to or concurrently with the approval of any tentative map. 2. Final fuel modification plans shall be submitted to and approved by the fire code official prior to the issuance of a grading permit. 3. The fuel modification plans shall meet the criteria set forth in the Fuel VUIUGIII It: — I CGI II IR:c71 VCSILj and Maintenance Program." 3.1 The fuel modification plan shall include provisions for the maintenance of the fuel modification in perpetuity. 4. The fuel modification plan may be altered if conditions change. Any alterations to the fuel modification areas shall have prior approval from the fire code official. 5. All elements of the fuel modification plan shall be maintained in accordance with the approved plan and are subject to the enforcement process outlined in the Fire Code. SECTION 27: Section 14-39 is hereby amended as follows: Sec. 14-39. - Flammable and combustible liquids (Chapter 57). Flammable and Combustible Liquids (Chapter 57) is adopted in its entirety with the exception of Section 5707 and with the following amendment: Section 5701.1.1 On -Demand Mobile fueling is added as follows: SECTION 28: Section 14-40 is hereby added as follows: Ordinance No. NS-XXXX Page 28 of 36 Sec. 14-40. — Flammable Gases and Flammable Cryogenic Fluids (Chapter 58) Chapter 58 Flammable Gases and Flammable Cryogenic Fluids is adopted with the exception of section 5809, in its entirety and with the following amendment: Section 5801.1 Scope is revised as follows: Section 5801.1 Scope. The storage and use of flammable gases and flammable cryogenic fluids shall be in accordance with this chapter, NFPA 2 and NFPA 55. Compressed gases shall also comply with Chapter 53 and cryogenic fluids shall also comply with Chapter 55. Flammable cryogenic fluids shall comply with Section 5806. Hydrogen motor fuel -dispensing stations and repair garages and their associated above -ground hydrogen storage systems shall also be designed, constructed and maintained in accordance with Chapter 23. Mobile fueling of gaseous and liquid hydrogen, compressed natural gas (CNG), and liquefied natural gas (LNG) into the fuel tanks of vehicles is prohibited. Exceptions: 1. Gases used as refriaerants in refriaeration systems (see Section 6 2. Liquefied petroleum gases and natural gases regulated by Chapter 61. 3. Fuel -gas systems and appliances regulated under the California Mechanical Code and the California Plumbing Code other than gaseous hydrogen systems and appliances. 4. P_yrophoric gases in accordance with Chapter 64. SECTION 29: Section 14-41 is hereby amended to read as follows: Sec. 14-41. - Referenced standards (Chapter 80). (a) NFPA 13, 2016 Edition, Standard for the Installation of Sprinkler Systems is hereby amended as follows: (1) Section 6.7.3 is hereby amended as follows: Ordinance No. NS-XXXX Page 29 of 36 Fire department connections (FDC) shall be of an approved type. The location shall be approved and be no more than 150 feet from a public hydrant. The FDC may be located within 150 feet of a private fire hydrant when aporoved by the fire code official. The size of piping and the number of 2'/2" inlets shall be approved by the fire code official. If acceptable to the water authority, it may be installed on the backflow assembly. Fire department inlet connections shall be painted OSHA safety red or as approved. When the fire sprinkler density design requires more than 500 qpm (including inside hose stream demand), or a standpipe system is included, four 2'/2" inlets shall be provided. (2) Section 8.3.3.1 is hereby amended as follows: 8.3.3.1. When fire sprinkler systems are installed in shell buildings of undetermined use (Spec Buildings) other than warehouses (S occupancies), fire sprinklers of the quick -response type shall be used. Use is considered undetermined if a specific tenant/occupant is not identified at the time the fire sprinkler plan is submitted. Sprinklers in light hazard occupancies shall be one of the following: Quick -response type as defined in 3.6.4.8 2. Residential sprinklers in accordance with the requirements of 8.4.5 3. Quick response CMSA sprinklers 4. ESFR sprinklers 5. Standard -response sprinklers used for modifications or additions to existing light hazard systems equipped with standard -response sprinklers 6. Standard -response sprinklers used where individual standard -response sprinklers are replaced in existing light hazard systems (3) Section 8.15.1.2.7 is hereby added and revised as follows: 8.15.1.2.7 Concealed spaces filled with noncombustible insulation shall not require sprinkler protection when approved by the fire code official. (.3 4) Section 11.1.1.1 is hereby added as follows: 11.1.1.1 When fire sprinkler systems are reauired in buildinas of undetermined use other than warehouses, they shall be designed and installed to have a fire sprinkler density of not less than that required for an Ordinary Hazard Group 2 use, with no reduction(s) in density or design area. Warehouse fire sprinkler systems shall be designed to Figure 16.2.1.3.2 (d) curve "G". Use is considered Ordinance No. NS-XXXX Page 30 of 36 undetermined if a specific tenant/occupant is not identified at the time the sprinkler plan is submitted. Where a subsequent occupancy requires a system with greater capability, it shall be the responsibility of the occupant to upgrade the system to the required density for the new occupancy. (4 5) Section 11.2.3.1.1.1 is hereby added as follows: 11.2.3.1.1.1 The available water supply for fire sprinkler system design shall be determined by one of the following methods, as approved by the Fire Code Official: 1) Subtract the project site elevation from the low water level for the appropriate pressure zone and multiply the result by 0.433; 2) Use a maximum of 40 psi, if available; approved third party licensed in the State of California. NFPA 13D 2016 Edition. Standard for the Installation of Sprinkler Systems in One- and Two -Family Dwellings and Manufactured Homes is hereby amended as follows: Section 7.1.2 is hereby revised as follows: 7.1.2 The sprinkler system piping shall not have separate control valves installed unless supervised by a central station, proprietary, or remote station alarm service one of the following methods: (1) Central station, proprietary, or remote station alarm service. (2) Local alarm service that causes the sounding of an audible signal at a constantly attended location. (3) Valves that are locked open. NFPA 14, 2013 Edition, Installation of Standpipe and Hose Systems is hereby amended as follows: Section 7.3.1.1 is hereby is deleted in its entirety and replaced as follows: 7.3.1.1 Class I and III Standpipe hose connections shall be unobstructed and shall be located not less than 18 inches or more than 24 inches above the finished floor. Class II Standpipe hose connections shall be unobstructed and shall be located not less than 3 feet or more than 5 feet above the finished floor Ordinance No. NS-XXXX Page 31 of 36 Section 6.2.8.1 is hereby added as follows: 6.2.8.1 All indicating valves controlling fire suppression water supplies shall be painted OSHA red. Exceptions: 1. Brass or bronze valves on sprinkler risers mounted to the exterior of the building may be left unpainted. 2. Where OS&Y valves on the detector check assembly are the only control valves, at least one OS&Y valve shall be painted red. Section 6.2.9 is hereby amended as follows: All connections to private fire service mains for fire protection systems shall be arranged in accordance with one of the following so that they can be isolated: (1) A post indicator valve installed not less than 40 ft (12 m) from the building (a) For buildings less than 40 ft (12 m) in height a post indicator valve shall be permitted to be installed closer than 40 ft (12 m) but at least as far from the building as the height of the wall facing the post indicator valve. (2) A wall post indicator valve (3) An indicating valve in a pit, installed in accordance with Section 6.4 (4) A backflow preventer with at least one indicating valve not less than 40 ft (12 m) from the building (a) For buildings less than 40 ft (12 m) in height, a backflow preventer with at least one indicating valve shall be permitted to be installed closer than 40 ft (12 m) but at least as far from the building as the height of the wall facing the backflow preventer. Ordinance No. NS-XXXX Page 32 of 36 (raMontrol valves installed in a fire -rated room accessible from the exterior. (-76)Control valves in a fire -rated stair enclosure accessible from the exterior. Section 10.1.5 is hereby added as follows: 10.1.5 All ferrous pipe and joints shall be polyethylene encased per AWWA C150, Method A, B, or C. All fittings shall be protected with a loose 8- mil polyethylene tube or sheet. The ends of the tube or sheet shall extend past the joint by a minimum of 12 inches and be sealed with 2 inch wide tape approved for underground use. Galvanizing does not meet the requirements of this section. Exception: 304 or 316 Stainless Steel pipe and fittings Section 10.4.1.1 is herebv revised as follows: 10.4.1.1 All bolted joint accessories shall be cleaned and thoroughly coated with asphalt or other corrosion -retarding material after installation. Exception: Bolted joint accessories made from 304 or 316 stainless steel. Section 10.4.1.1.1 is hereby added as follows: 10.4.1.1.1 All bolts used in pipe -joint assembly shall be 316 stainless steel. Ordinance No. NS-XXXX Page 33 of 36 Section 10.4.3.2 is herebv deleted and replaced as follows 10.4.3.2 Where approved private fire service mains supplying systems within the building shall be permitted to extend more than 10 ft. under the building when all of the requirements of 10.4.3.2.1 through 10.4.3.2.4 are met. Where fire service mains enter the building adjacent to the foundation, the pipe may run under a building to a maximum of 24 inches, as measured from the interior face of the exterior wall to the center of the vertical pipe. The pipe under the building or building foundation shall be 304 or 316 stainless steel and shall not contain mechanical ioints or it shall comply with 10.4.3.2.1 through 10.4.3.2.4. SECTION 30: Section 14-47 is hereby amended to read as follows Sec. 14-47. Appendices. Appendix A is deleted in its entirety without amendments. Appendix B is adopted in its entirety witheat amendments outlined in Guideline B-09. Appendix BB is adopted in its entirety without amendments. Appendix C is adopted in its entirety without amendments. Appendix CC is adopted in its entiretv without amendments Appendix D is deleted in its entirety without amendments. Appendix E is deleted in its entirety without amendments. Appendix F is deleted in its entirety without amendments. Appendix G is deleted in its entirety without amendments. Appendix H is deleted in its entirety without amendments. Appendix I is deleted in its entirety without amendments. Appendix J is deleted in its entirety without amendments. Appendix K is deleted in its entirety without amendments. Appendix L is deleted in its entirety without amendments. Appendix M is deleted in its entirety without amendments. Ordinance No. NS-XXXX Page 34 of 36 Appendix N is deleted in its entirety without amendments. Appendix O is deleted in its entirety without amendments. SECTION 31: All provisions of the Santa Ana Municipal Code which are repeated herein are repeated solely in order to comply with the provisions of Section 418 of the City Charter. Any such restatement of existing provisions of the Code is not intended, nor shall it be interpreted, as constituting a new action or decision of the City Council, but rather such provisions are repeated for tracking purposes only in conformance with the Charter. SECTION 32: Neither the adoption of this ordinance nor the repeal hereby of any ordinance shall in any manner affect the prosecution for violation or ordinances, which violations were committed prior to the effective date hereof, nor be construed as affecting any of the provisions of such ordinance relating to the collection of any such license or penalty or the penal provision applicable to any violation thereof, nor to affect the validity of any bond or cash deposit in lieu thereof, required to be posted, filed or deposited pursuant to any ordinance and all rights and obligations there under appertaining shall continue in full force and effect. SECTION 33: If any section, subsection, sentence, clause, phrase, or portion of this ordinance is for any reason held to be invalid or unconstitutional by the decision of any court of competent jurisdiction, such decision shall not affect the validity of the remaining portions of this ordinance. The City Council of the City of Santa Ana hereby declares that it would have adopted this ordinance and each section, subsection, sentence, clause, phrase or portion thereof irrespective of the fact that any one or more sections, subsections, sentences, clauses, phrases, or portions be declared invalid or unconstitutional. ADOPTED this _ day of November, 2019 Miguel A. Pulido Mayor APPROVED AS TO FORM: Sonia R. Carvalho, City Attorney By: Lish Storck Assistant City Attorney Ordinance No. NS-XXXX Page 35 of 36 AYES: Councilmembers: NOES: Councilmembers: ABSTAIN: Councilmembers: NOT PRESENT: Councilmembers: CERTIFICATE OF ATTESTATION AND ORIGINALITY I, DAISY GOMEZ, Clerk of the Council, do hereby attest to and certify that the attached Ordinance No. NS-XXXX to be the original ordinance adopted by the City Council of the City of Santa Ana on November_, 2019 and that said ordinance was published in accordance with the Charter of the City of Santa Ana. Date: Clerk of the Council City of Santa Ana Ordinance No. NS-XXXX Page 36 of 36 *:1:11-11111V LS 11.19.19 RESOLUTION NO.2019-xx A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF SANTA ANA CALIFORNIA, SETTING FORTH FINDINGS WITH RESPECT TO LOCAL CONDITIONS WITHIN THE CITY OF SANTA ANA WHICH JUSTIFY CERTAIN MODIFICATIONS AND CHANGES TO THE CALIFORNIA BUILDING CODE, CALIFORNIA RESIDENTIAL CODE, CALIFORNIA GREEN BUILDING STANDARDS CODE, CALIFORNIA ELECTRICAL CODE, CALIFORNIA MECHANICAL CODE, CALIFORNIA PLUMBING CODE, CALIFORNIA ENERGY CODE, CALIFORNIA FIRE CODE, CALIFORNIA EXISTING BUILDING CODE, AND INTERNATIONAL PROPERTY MAINTENANCE CODE AS AMENDED BY THE STATE OF CALIFORNIA BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF SANTA ANA AS FOLLOWS: Section 1. The City Council hereby finds, determines, and declares as follows: A. Health and Safety Code Section 17958 provides that the City of Santa Ana shall adopt Ordinances and regulations imposing the same or modified or changed requirements as are contained in the regulations adopted by the State pursuant to Health and Safety Code Section 17922. B. The State of Califomia is mandated by Health and Safety Code Section 17922 to impose the same requirements as are contained in the most recent edition of the Califomia Building Code, Califomia Existing Building Code, the Califomia Plumbing Code, the Califomia Mechanical Code, California Energy Code, and the California Electrical Code (hereinafter referred to collectively as "Codes"). C. Health and Safety Code Section 17958.5(a) permits the City to make modifications or changes to the Codes, which are reasonably necessary because of local climatic, geographic or topographic conditions. D. Health and Safety Code Section 17958.7 requires that the City Council, before making any modifications or changes to the Codes, shall make an express finding that such changes or modifications are reasonably necessary because of local climatic, geographic or topographic conditions. Section 2: The Planning and Building Agency and the Orange County Fire Authority (OCFA) have recommended that changes and modifications be made to the Codes and have Resolution No. 2019- Page 1 of 8 advised that certain said changes and modifications to the California Building Code, 2019 Edition, the California Existing Building Code, 2019 Edition, the California Plumbing Code, 2019 Edition, the California Mechanical Code, 2019 Edition, the California Electrical Code, 2019 Edition, the California Existing Building Code, 2019 Edition, California Energy Code, 2019 Edition, and the California Fire Code, 2019 Edition, are reasonably necessary due to local conditions in the City of Santa Ana. Section 3. Amendments to the 2019 Edition of the California Building Code, the 2019 Edition of the California Existing Building Code, the 2019 Edition of the California Residential Code, and the 2019 Edition of the California Fire Code as recommended by the Planning and Building Agency and the Orange County Fire Authority are hereby found to be reasonably necessary based upon the following findings: I. Climatic Conditions A. The jurisdiction of Santa Ana is located in a semi -arid Mediterranean type climate. It annually experiences extended periods of high temperatures with little or no precipitation. Hot, dry (Santa Ana) winds, which may reach speeds of 70 M.P.H. or greater, are also common to the area. These climatic conditions cause extreme drying of vegetation and common building materials. Frequent periods of drought and low humidity add to the fire danger. This predisposes the area to large destructive fires (conflagration). In addition to directly damaging or destroying buildings, these fires are also prone to disrupt utility services throughout the County. Obstacles generated by a strong wind, such as fallen trees, street lights and utility poles will greatly impact the response time to reach an incident scene. B. The climate alternates between extended periods of drought and brief flooding conditions. Flood conditions may affect the Orange County Fire Authority's ability to respond to a fire or emergency condition. Floods also disrupt utility services to buildings and facilities within the County. C. Water demand in this densely populated area far exceeds the quantity supplied by natural precipitation; and although the population continues to grow, the already -taxed water supply does not. California is projected to increase in population by nearly 10 million over the next quarter of a century with 50 percent of that growth centered in Southern California. Due to storage capacities and consumption, and a limited amount of rainfall future water allocation is not fully dependable. This necessitates the need for additional and on -site fire protection features. D. These dry climatic conditions and winds contribute to the rapid spread of even small fires originating in high -density housing or vegetation. These fires spread very quickly and create a need for increased levels of fire protection. The added protection of fire sprinkler systems and other fire Resolution No. 2019- Page 2 of 8 protection features will supplement normal fire department response by providing immediate protection for the building occupants and by containing and controlling the fire spread to the area of origin. Fire sprinkler systems will also reduce the use of water for firefighting by as much as 50 to 75 percent. II. Topographical conditions A. Natural; slopes of 15 percent or greater generally occur throughout the foothills of Orange County. The elevation change cause by the hills creates the geological foundation on which communities with Orange County is built and will continue to build. With much of the populated flatlands already built upon, future growth will occur steeper slopes and greater constraints in terrain. B. Traffic and circulation congestion is an artificially created, obstructive topographical condition, which is common throughout Orange County. C. These topographical conditions combine to create a situation, which places fire department response time to fire occurrences at risk, and makes it necessary to provide automatic on -site fire -extinguishing systems and other protection measures to protect occupants and property. III. Geological Conditions The Orange County region is a densely populated area that has buildings constructed over and near a vast and complex network of faults that are believed to be capable of producing future earthquakes similar or greater in size that the 1994 Northridge and the 1971 Sylmar earthquakes. Earthquake faults run along the northeast and southwest boundaries of Orange County. The Newport -Inglewood Fault, located within Orange County was the source of the destructive 1933 Long Beach earthquake (6.3 magnitude) which took 120 lives and damaged buildings in an area from Laguna Beach to Marina Del Rey to Whittier. In December 1989, another earthquake occurred in the jurisdiction of Irvine at an unknown fault line. Regional planning for reoccurrence of earthquakes is recommended by the State of California, Department of Conservation. A. Previous earthquakes have been accompanied by disruption of traffic flow and fires. A severe seismic event has the potential to negatively impact any rescue or fire suppression activities because it is likely to create obstacles similar to those indicated under the high wind section above. With the probability of strong aftershocks there exists a need to provide increased protection for anyone on upper floors of buildings. The October 17, 1989, Santa Cruz earthquake resulted in one major fire in the Marina District (San Francisco). When combined with the 34 other fires locally Resolution No. 2019- Page 3 of 8 and over 500 responses, the department was taxed to its fullest capabilities. The Marina fire was difficult to contain because mains supplying water to the district burst during the earthquake. This situation creates the need for both additional fire protection and automatic on -site fire protection for building occupants. State Department of Conservation noted in their 1988 report (Planning Scenario on a Major Earthquake on the Newport -Inglewood Fault Zone, page 59), "unfortunately, barely meeting the minimum earthquake standards of building codes places a building on the verge of being legally unsafe." B. Road circulation features located throughout the County also make amendments reasonably necessary. Located through the County are major roadways, highways and flood control channels that create barriers and slow response times. Hills, slopes, street and storm drain design accompanies with occasional heavy rainfall, causes roadway flooding and landslides and at times may make an emergency access route impassable. There are areas in Orange County that naturally have extended emergency response times that exceed the 5 minute goal. C. Soils throughout the County possess corrosive properties that reduce the expected usable life of water services when metallic pipes in contact with soils are utilized. Due to the topographical conditions of sprawling development separated by waterways and narrow and congested streets and the expected infrastructure damage inherent in seismic zone described above, it is prudent to rely on automatic fire sprinkler systems to mitigate extended fire department response time and keep fires manageable with reduced fire flow (water) requirements for a given structures. Additional fire protection is also justified to match the current resources of firefighting equipment and personnel within the Orange County Fire Authority. Section 4. The following specific amendments to the sections of the 2019 Edition of the California Building Code as recommended by the Planning and Building Agency and the Orange County Fire Authority are reasonably necessary based upon the corresponding findings in Section 3 of this resolution as listed below: BUILDING CODE SECTION TITLE (Clarification) FINDINGS I,II,III 105.1 Permits required Admin 105.3.2 Time Limitation of Application Admin 105.5 Permit Expiration Admin 111 Certificate of Occupancy Admin 202 r2O2 General definitions (Spark Arrester) Admin Resolution No. 2019- Page 4 of 8 903.2 Where required (Sprinklers) II & III-B 903.2.8 Group R (Sprinklers) II-B & III-B 903.3.5.3 Hydraulically calculated systems I & II J103.2 Grading Permit Exemption Admin, II & III 506.4.3 (CEBC) Seismic Loads (California Existing Building Code) II & III Section 5. The following specific amendments to the sections of the 2019 Edition of the California Residential Code as recommended by the Planning and Building Agency and the Orange County Fire Authority are reasonably necessary based upon the corresponding findings in Section 3 of this resolution as listed below: RESIDENTIAL CODE SECTION TITLE (Clarification) FINDINGS I,II,III R202 General definitions (Spark Arrester) Admin R301.9 Development on or near land containing or emitting toxic, combustible or flammable liquids, gases or vapors III R309.6 Fire sprinkler attached garages, carports with habitable space above III R313.1 Townhouse automatic fire sprinkler systems III R313.2 One- and two-family dwellings automatic fire sprinkler system III R313.3.6.2.2 Calculation procedures III R337.1.3 Application Admin, II & III R1001.13 Outdoor Fireplaces, Fire Pits, Fire Rings I & II R1001.13.1 Gas -fueled devices I & II R1001.13.2 Devices using wood I & II R1001.13.3 Devices using wood, where prohibited I & II Chapter44 Reference Standards 2016 NFPA 13-D (Single Family Sprinkler Systems) II & III Section 6. The following specific amendments to the sections of the 2019 Edition of the California Fire Code as recommended by the Planning and Building Agency and the Orange County Fire Authority are reasonably necessary based upon the corresponding findings in Section 3 of this resolution as listed below: Resolution No. 2019- Page 5 of 8 FIRE CODE SECTION TITLE (Clarification) FINDINGS I,II,III 110.4 Violation penalties Administrative 110.4.2 Infraction & Misdemeanor Administrative 202 General definitions Administrative 304.1.2 OCFA Vegetation Management 1 305.6 Hazardous conditions I & II 305.7 Disposal of rubbish I & II 307 Open burning, recreational fires, fire pits, fire rings, and outdoor fireplaces Administrative 307.6 Fire Pits, Fire Rings, & Outdoor Fireplaces Administrative 307.6.1 Gas -fueled devices I & II 307.6.2 Devices using wood or fuels other than natural gas or LPG I & 11 307.6.2.1 Where prohibited I & II 308.1.6.3 Sky lanterns I & III 321 Fuel modification requirements for new construction I 322 Clearance of brush or vegetation growth from roadways I 323 Unusual circumstances Administrative 324 Use of equipment 1 324.1 Use of equipment and devices generating heat, sparks or open flames I 324.2 Spark arresters I 407.5 Hazardous material inventory statement I & II 501.1 Scope Administrative, I, II & III 510.1 Emergency responder radio coverage Administrative 903.2 Where required (Sprinklers) I, II & III 903.2.8 Group R (Sprinklers) I, II & III 903.3.5.3 Hydraulically calculated systems I & II 1201.1.1 Energy systems, battery charging devices I & II 2801.2 Permit Administrative 2808.2 Storage site Administrative 2808.3 Size of piles I 2808.4 Pile separation I 2808.7 Pile fire protection I 2808.9 Material -handling equipment I 2808.11 Temperature control I 2808.11.1 Pile temperature control I Resolution No. 2019- Page 6 of 8 2808.11.2 New material temperature control 1 2808.12 Water availability for piles I 2808.13 Tipping area I 2808.14 Emergency contact Administrative 4906.3 OCFA Vegetation Management Guideline 1 4908 Fuel modification requirements for new construction I 5001.5.2 Hazardous materials inventory statement Administrative 5003.1.1.1 Extremely hazardous substances 1 & III 5608.2 Retail fireworks Administrative 5608.3 Application for permit Administrative 5701.1.1 On -Demand Mobile Fueling N/A 5801.1 Scope N/A Chapter 80 Reference Standards N/A 2016 NFPA 13 (Sprinkler Systems) Administrative, II & III 2016 NFPA 13-D (Single Family Sprinkler Systems) I & II 2013 NFPA 14 (Standpipe Systems) Administrative 2016 NFPA 24 (Underground Water Supply Systems) Administrative & III Section 7. The aforementioned amendments have been incorporated in detail in Ordinance NS- Section 8. Additional amendments have been made to the relevant California Building Code, California Existing Building Code, Electrical Code, Mechanical Code, Plumbing Code, Energy Code, Existing Building Code, Residential Code, Green Building Standards Code, Fire Code, and International Property Maintenance Code. On the recommendation of the Planning and Building Agency and the Orange County Fire Authority, such amendments are hereby found to be either administrative or procedural in nature or concern themselves with subjects not covered in the aforementioned Codes. The changes made include provisions making each of said Codes compatible with other Codes enforced by the City. Section 9. The City Council of the City of Santa Ana hereby approves and authorizes the Planning and Building Agency to file copies of Resolution 2019- and Ordinance NS- with the California Building Standards Commission as required by Health and Safety Code Section 17958.7. Section 10. This Resolution shall take effect from and after its adoption. Resolution No. 2019- Page 7 of 8 ADOPTED this day of 2019. Miguel Pulido Mayor APPROVED AS TO FORM: Sonia R. Carvalho City Attorney Lisa Storck Assistant City Attorney AYES: Councilmembers NOES: Councilmembers ABSTAIN: Counci NOT PRESENT: Counci CERTIFICATE OF ATTESTATION AND ORIGINALITY I, DAISY GOMEZ, Clerk of the Council, do hereby attest to and certify the attached Resolution No. 2019-xx to be the original resolution adopted by the City Council of the City of Santa Ana on 2019. Date: Clerk of the Council City of Santa Ana Resolution No. 2019- Page 8 of 8