Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Packet_3.24.24
Planning Commission Regular Meeting Agenda March 25, 2024 5:30 P.M. Council Chamber 22 Civic Center Plaza Santa Ana, CA Members of the public may attend this meeting inperson or join via Zoom. Join from your computer: https://zoom.us/j/84445428558 Join from your mobile phone via Zoom App. Meeting ID: 84445428558 Dial in from a mobile phone or landline.(669) 900 6833; Meeting ID: 84445428558 *For viewing only: www.youtube.com/cityofsantaanavideos. Please note: There is up to a 30 second delay when viewing the meeting via YouTube. If you plan to provide a public comment during the meeting, please join the meeting via Zoom. For detailed participation and commenting options, please review the instructions provided at the end of this agenda. To download or view each item, select either Download PDF or View Item Details to the right of the agenda title. BAO PHAM Chair, Ward 1 Representative JENNIFER OLIVA ViceChair Ward 6 Representative CHRISTOPHER LEO Citywide Representative MANUEL J. ESCAMILLA Ward 2 Representative CARL BENNINGER Ward 4 Representative ISURI S. RAMOS Ward 3 Representative ALAN WOO Ward 5 Representative Minh Thai Executive Director Jose Montoya Legal Counsel Ali Pezeshkpour, AICP Planning Manager Nuvia Ocampo Recording Secretary In compliance with the Americans with Disabilities Act (ADA), if you need special assistance to participate in this Meeting, contact Michael Ortiz, City ADA Program Coordinator, at (714) 6475624. Notification 48 hours prior to the Meeting will enable the City to make reasonable arrangements to assure accessibility to this meeting. The City Council agenda and supporting documentation can be found on the City’s website – www.santaana.org/citymeetings. CALL TO ORDER Commissioners: Bao Pham, Chair Manuel Escamilla Christopher Leo Carl Benninger Jennifer Oliva Isuri S. Ramos Alan Woo Executive Director Minh Thai Assistant City Attorney Jose Montoya Planning Manager Ali Pezeshkpour, AICP Recording Secretary Nuvia Ocampo ROLL CALL PLEDGE OF ALLEGIANCE PUBLIC COMMENTS CONSENT CALENDAR ITEMS a.Minutes Recommended Action: Approve Minutes from March 11, 2024. b.Excused Absences Recommended Action: Excuse absent commissioners. *End of Consent Calendar* BUSINESS CALENDAR Public Hearing:The Planning Commission decision on Conditional Use Permits, Variances, Tentative Tract and Parcel Maps, Minor Exceptions, Site Plan Review, and Public Convenience or Necessity Determinations are final unless appealed within 10 days of the decision by any interested party or group (refer to the Basic Meeting Information page for more information). The Planning Commission recommendation on Zoning and General Plan amendments, Development Agreements, Specific Developments, and Specific Plans will be forwarded to the City Council for final determination. Legal notice was published in the OC Reporter on March 15, 2024 and notices were mailed on said date. 1.SITE PLAN REVIEW NO. 2024‐01 AND TENTATIVE TRACT MAP NO. 2024‐01 FOR THE PROPERTIES LOCATED AT 101, 111, 115, AND 121 NORTH HARBOR BOULEVARD, AT 3709 AND 3729 WEST FIRST STREET AND AT 114 NORTH FIGUEROA STREET, LOCATED WITHIN THE TRANSIT NODE SOUTH (TNS) DISTRICT OF THE HARBOR MIXED‐USE TRANSIT CORRIDOR SPECIFIC PLAN (SP‐2). Project Applicant: Charles Minyard with Primior, Inc. and representing Harbor and First, LLC. (Applicant & Property Owner) Proposed Project: Applicant is requesting approval of Site Plan Review (SPR) No. 202401 and Tentative Tract Map (TTM) No. 202401 to facilitate the construction of a mixeduse development known as First Harbor MixedUse Development, which would develop an existing vacant lot with a ninestory mixeduse building consisting of 15,182 square feet of leasable commercial space, 1,845 square feet of leasing office space, 181 forsale residential condominium units (including 10 onsite affordable units), 339 parking spaces, and 40,853 square feet of open space and amenities. Environmental Impact: Pursuant to the California Environment Quality Act (CEQA), the project is within the scope of the 2014 Harbor Boulevard MixedUse Transit Corridor Plan Environmental Impact Report (EIR) (SCH No. 2013061027). Recommended Actions: 1. Adopt a resolution approving Site Plan Review No. 202401 as conditioned. 2. Adopt a resolution approving Tentative Tract Map No. 202401 as conditioned. *End of Business Calendar* WORK STUDY SESSION Annual Budget Process – Shannon McCarron, Finance and Management Services *End of Work Study Session Calendar* STAFF COMMENTS COMMISSIONER COMMENTS ADJOURNMENT The next meeting of the Planning Commission will be on April 08, 2024 at 5:30 PM in the Council Chambers located at 22 Civic Center Plaza, Santa Ana, CA 92701. APPEAL INFORMATION The formal action by the Planning Commission shall become effective after the tenday appeal period, unless the City Council in compliance with section 41643, 41644 or 41645 holds a public hearing on the matter, then the formal action will become effective on the day following the hearing and decision by the City Council. An appeal from the decision or requirement of the Planning Commission may be made by any interested party, individual, or group. The appeal must be filed with the Clerk of the Council, accompanied by the required filing fee, and a copy sent to the Planning Department, within ten days of the date of the Commission's action, by 5:00 p.m. If the final day to appeal falls on a City Hall observed holiday or a day when City hall is closed, the final day to appeal shall be extended to the next day City Hall is open for public business. Please note: Under California Government Code Sec. 65009, if you challenge in court any of the matters on this agenda for which a public hearing is to be conducted, you may be limited to raising only those issues which you (or someone else) raised orally at the public hearing or in written correspondence received by the Planning Commission or City Council at or before the hearing. MEETING INFORMATION If you would like to learn how to use Zoom before the meeting, visit Zoom Video Tutorials. 1. Connecting directly from your computer: Click on the link on top of this agenda OR Go to Zoom.us and click "Join a Meeting" at the top. Enter the Meeting ID. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, click on the button next to your name to virtually raise your hand and let us know you wish to speak. You will have 3 minutes. 2. Connecting via the Zoom App: Download the free Zoom Cloud Meetings app from your favorite app store. Launch the app and click on the blue Join a Meeting button. Enter the Meeting ID, your name, and the blue Join button. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, click on the button next to your name to virtually raise your hand and let us know you wish to speak. You will have 3 minutes. 3. Dialing in from a mobile phone or landline: Dial (669) 9009128. When prompted, enter the meeting ID. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, press *9 on your phone to virtually raise your hand. You will have 3 minutes. Submit a written comment You are invited to submit a written comment in one of the following ways: Email PBAecomments@santaana.org and reference the topic in the subject line. Mail to Nuvia Ocampo, Recording Secretary, City of Santa Ana, 20 Civic Center Plaza – M20, Santa Ana, CA 92701. Deadline to submit written comments is 4:00 p.m. on the day of the meeting.Comments received after the deadline may not be distributed to the Commission but will be made part of the record. Planning CommissionRegular Meeting AgendaMarch 25, 20245:30 P.M.Council Chamber22 Civic Center PlazaSanta Ana, CA Members of the public may attend this meeting inperson or join via Zoom.Join from your computer: https://zoom.us/j/84445428558Join from your mobile phone via Zoom App. Meeting ID: 84445428558Dial in from a mobile phone or landline.(669) 900 6833; Meeting ID: 84445428558*For viewing only: www.youtube.com/cityofsantaanavideos. Please note: There is up to a 30second delay when viewing the meeting via YouTube. If you plan to provide a public commentduring the meeting, please join the meeting via Zoom.For detailed participation and commenting options, please review the instructionsprovided at the end of this agenda. To download or view each item, select either Download PDF or View Item Details to the right of the agenda title. BAO PHAM Chair, Ward 1 Representative JENNIFER OLIVA ViceChair Ward 6 Representative CHRISTOPHER LEO Citywide Representative MANUEL J. ESCAMILLA Ward 2 Representative CARL BENNINGER Ward 4 Representative ISURI S. RAMOS Ward 3 Representative ALAN WOO Ward 5 Representative Minh Thai Executive Director Jose Montoya Legal Counsel Ali Pezeshkpour, AICP Planning Manager Nuvia Ocampo Recording Secretary In compliance with the Americans with Disabilities Act (ADA), if you need special assistance to participate in this Meeting, contact Michael Ortiz, City ADA Program Coordinator, at (714) 6475624. Notification 48 hours prior to the Meeting will enable the City to make reasonable arrangements to assure accessibility to this meeting. The City Council agenda and supporting documentation can be found on the City’s website – www.santaana.org/citymeetings. CALL TO ORDER Commissioners: Bao Pham, Chair Manuel Escamilla Christopher Leo Carl Benninger Jennifer Oliva Isuri S. Ramos Alan Woo Executive Director Minh Thai Assistant City Attorney Jose Montoya Planning Manager Ali Pezeshkpour, AICP Recording Secretary Nuvia Ocampo ROLL CALL PLEDGE OF ALLEGIANCE PUBLIC COMMENTS CONSENT CALENDAR ITEMS a.Minutes Recommended Action: Approve Minutes from March 11, 2024. b.Excused Absences Recommended Action: Excuse absent commissioners. *End of Consent Calendar* BUSINESS CALENDAR Public Hearing:The Planning Commission decision on Conditional Use Permits, Variances, Tentative Tract and Parcel Maps, Minor Exceptions, Site Plan Review, and Public Convenience or Necessity Determinations are final unless appealed within 10 days of the decision by any interested party or group (refer to the Basic Meeting Information page for more information). The Planning Commission recommendation on Zoning and General Plan amendments, Development Agreements, Specific Developments, and Specific Plans will be forwarded to the City Council for final determination. Legal notice was published in the OC Reporter on March 15, 2024 and notices were mailed on said date. 1.SITE PLAN REVIEW NO. 2024‐01 AND TENTATIVE TRACT MAP NO. 2024‐01 FOR THE PROPERTIES LOCATED AT 101, 111, 115, AND 121 NORTH HARBOR BOULEVARD, AT 3709 AND 3729 WEST FIRST STREET AND AT 114 NORTH FIGUEROA STREET, LOCATED WITHIN THE TRANSIT NODE SOUTH (TNS) DISTRICT OF THE HARBOR MIXED‐USE TRANSIT CORRIDOR SPECIFIC PLAN (SP‐2). Project Applicant: Charles Minyard with Primior, Inc. and representing Harbor and First, LLC. (Applicant & Property Owner) Proposed Project: Applicant is requesting approval of Site Plan Review (SPR) No. 202401 and Tentative Tract Map (TTM) No. 202401 to facilitate the construction of a mixeduse development known as First Harbor MixedUse Development, which would develop an existing vacant lot with a ninestory mixeduse building consisting of 15,182 square feet of leasable commercial space, 1,845 square feet of leasing office space, 181 forsale residential condominium units (including 10 onsite affordable units), 339 parking spaces, and 40,853 square feet of open space and amenities. Environmental Impact: Pursuant to the California Environment Quality Act (CEQA), the project is within the scope of the 2014 Harbor Boulevard MixedUse Transit Corridor Plan Environmental Impact Report (EIR) (SCH No. 2013061027). Recommended Actions: 1. Adopt a resolution approving Site Plan Review No. 202401 as conditioned. 2. Adopt a resolution approving Tentative Tract Map No. 202401 as conditioned. *End of Business Calendar* WORK STUDY SESSION Annual Budget Process – Shannon McCarron, Finance and Management Services *End of Work Study Session Calendar* STAFF COMMENTS COMMISSIONER COMMENTS ADJOURNMENT The next meeting of the Planning Commission will be on April 08, 2024 at 5:30 PM in the Council Chambers located at 22 Civic Center Plaza, Santa Ana, CA 92701. APPEAL INFORMATION The formal action by the Planning Commission shall become effective after the tenday appeal period, unless the City Council in compliance with section 41643, 41644 or 41645 holds a public hearing on the matter, then the formal action will become effective on the day following the hearing and decision by the City Council. An appeal from the decision or requirement of the Planning Commission may be made by any interested party, individual, or group. The appeal must be filed with the Clerk of the Council, accompanied by the required filing fee, and a copy sent to the Planning Department, within ten days of the date of the Commission's action, by 5:00 p.m. If the final day to appeal falls on a City Hall observed holiday or a day when City hall is closed, the final day to appeal shall be extended to the next day City Hall is open for public business. Please note: Under California Government Code Sec. 65009, if you challenge in court any of the matters on this agenda for which a public hearing is to be conducted, you may be limited to raising only those issues which you (or someone else) raised orally at the public hearing or in written correspondence received by the Planning Commission or City Council at or before the hearing. MEETING INFORMATION If you would like to learn how to use Zoom before the meeting, visit Zoom Video Tutorials. 1. Connecting directly from your computer: Click on the link on top of this agenda OR Go to Zoom.us and click "Join a Meeting" at the top. Enter the Meeting ID. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, click on the button next to your name to virtually raise your hand and let us know you wish to speak. You will have 3 minutes. 2. Connecting via the Zoom App: Download the free Zoom Cloud Meetings app from your favorite app store. Launch the app and click on the blue Join a Meeting button. Enter the Meeting ID, your name, and the blue Join button. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, click on the button next to your name to virtually raise your hand and let us know you wish to speak. You will have 3 minutes. 3. Dialing in from a mobile phone or landline: Dial (669) 9009128. When prompted, enter the meeting ID. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, press *9 on your phone to virtually raise your hand. You will have 3 minutes. Submit a written comment You are invited to submit a written comment in one of the following ways: Email PBAecomments@santaana.org and reference the topic in the subject line. Mail to Nuvia Ocampo, Recording Secretary, City of Santa Ana, 20 Civic Center Plaza – M20, Santa Ana, CA 92701. Deadline to submit written comments is 4:00 p.m. on the day of the meeting.Comments received after the deadline may not be distributed to the Commission but will be made part of the record. Planning CommissionRegular Meeting AgendaMarch 25, 20245:30 P.M.Council Chamber22 Civic Center PlazaSanta Ana, CA Members of the public may attend this meeting inperson or join via Zoom.Join from your computer: https://zoom.us/j/84445428558Join from your mobile phone via Zoom App. Meeting ID: 84445428558Dial in from a mobile phone or landline.(669) 900 6833; Meeting ID: 84445428558*For viewing only: www.youtube.com/cityofsantaanavideos. Please note: There is up to a 30second delay when viewing the meeting via YouTube. If you plan to provide a public commentduring the meeting, please join the meeting via Zoom.For detailed participation and commenting options, please review the instructionsprovided at the end of this agenda.To download or view each item, select either Download PDF or View Item Details tothe right of the agenda title. BAO PHAMChair, Ward 1 RepresentativeJENNIFER OLIVAViceChairWard 6 Representative CHRISTOPHER LEOCitywide RepresentativeMANUEL J. ESCAMILLAWard 2 Representative CARL BENNINGERWard 4 RepresentativeISURI S. RAMOSWard 3 Representative ALAN WOOWard 5 RepresentativeMinh ThaiExecutive DirectorJose MontoyaLegal Counsel Ali Pezeshkpour, AICPPlanning Manager Nuvia OcampoRecording Secretary In compliance with the Americans with Disabilities Act (ADA), if you need special assistance to participate in this Meeting, contact Michael Ortiz, City ADA Program Coordinator, at (714) 6475624. Notification 48 hours prior to the Meeting will enable the City to make reasonable arrangements to assure accessibility to this meeting. The City Council agenda and supporting documentation can be found on the City’s website – www.santaana.org/citymeetings. CALL TO ORDER Commissioners: Bao Pham, Chair Manuel Escamilla Christopher Leo Carl Benninger Jennifer Oliva Isuri S. Ramos Alan Woo Executive Director Minh Thai Assistant City Attorney Jose Montoya Planning Manager Ali Pezeshkpour, AICP Recording Secretary Nuvia Ocampo ROLL CALL PLEDGE OF ALLEGIANCE PUBLIC COMMENTS CONSENT CALENDAR ITEMS a.Minutes Recommended Action: Approve Minutes from March 11, 2024. b.Excused Absences Recommended Action: Excuse absent commissioners. *End of Consent Calendar* BUSINESS CALENDAR Public Hearing:The Planning Commission decision on Conditional Use Permits, Variances, Tentative Tract and Parcel Maps, Minor Exceptions, Site Plan Review, and Public Convenience or Necessity Determinations are final unless appealed within 10 days of the decision by any interested party or group (refer to the Basic Meeting Information page for more information). The Planning Commission recommendation on Zoning and General Plan amendments, Development Agreements, Specific Developments, and Specific Plans will be forwarded to the City Council for final determination. Legal notice was published in the OC Reporter on March 15, 2024 and notices were mailed on said date. 1.SITE PLAN REVIEW NO. 2024‐01 AND TENTATIVE TRACT MAP NO. 2024‐01 FOR THE PROPERTIES LOCATED AT 101, 111, 115, AND 121 NORTH HARBOR BOULEVARD, AT 3709 AND 3729 WEST FIRST STREET AND AT 114 NORTH FIGUEROA STREET, LOCATED WITHIN THE TRANSIT NODE SOUTH (TNS) DISTRICT OF THE HARBOR MIXED‐USE TRANSIT CORRIDOR SPECIFIC PLAN (SP‐2). Project Applicant: Charles Minyard with Primior, Inc. and representing Harbor and First, LLC. (Applicant & Property Owner) Proposed Project: Applicant is requesting approval of Site Plan Review (SPR) No. 202401 and Tentative Tract Map (TTM) No. 202401 to facilitate the construction of a mixeduse development known as First Harbor MixedUse Development, which would develop an existing vacant lot with a ninestory mixeduse building consisting of 15,182 square feet of leasable commercial space, 1,845 square feet of leasing office space, 181 forsale residential condominium units (including 10 onsite affordable units), 339 parking spaces, and 40,853 square feet of open space and amenities. Environmental Impact: Pursuant to the California Environment Quality Act (CEQA), the project is within the scope of the 2014 Harbor Boulevard MixedUse Transit Corridor Plan Environmental Impact Report (EIR) (SCH No. 2013061027). Recommended Actions: 1. Adopt a resolution approving Site Plan Review No. 202401 as conditioned. 2. Adopt a resolution approving Tentative Tract Map No. 202401 as conditioned. *End of Business Calendar* WORK STUDY SESSION Annual Budget Process – Shannon McCarron, Finance and Management Services *End of Work Study Session Calendar* STAFF COMMENTS COMMISSIONER COMMENTS ADJOURNMENT The next meeting of the Planning Commission will be on April 08, 2024 at 5:30 PM in the Council Chambers located at 22 Civic Center Plaza, Santa Ana, CA 92701. APPEAL INFORMATION The formal action by the Planning Commission shall become effective after the tenday appeal period, unless the City Council in compliance with section 41643, 41644 or 41645 holds a public hearing on the matter, then the formal action will become effective on the day following the hearing and decision by the City Council. An appeal from the decision or requirement of the Planning Commission may be made by any interested party, individual, or group. The appeal must be filed with the Clerk of the Council, accompanied by the required filing fee, and a copy sent to the Planning Department, within ten days of the date of the Commission's action, by 5:00 p.m. If the final day to appeal falls on a City Hall observed holiday or a day when City hall is closed, the final day to appeal shall be extended to the next day City Hall is open for public business. Please note: Under California Government Code Sec. 65009, if you challenge in court any of the matters on this agenda for which a public hearing is to be conducted, you may be limited to raising only those issues which you (or someone else) raised orally at the public hearing or in written correspondence received by the Planning Commission or City Council at or before the hearing. MEETING INFORMATION If you would like to learn how to use Zoom before the meeting, visit Zoom Video Tutorials. 1. Connecting directly from your computer: Click on the link on top of this agenda OR Go to Zoom.us and click "Join a Meeting" at the top. Enter the Meeting ID. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, click on the button next to your name to virtually raise your hand and let us know you wish to speak. You will have 3 minutes. 2. Connecting via the Zoom App: Download the free Zoom Cloud Meetings app from your favorite app store. Launch the app and click on the blue Join a Meeting button. Enter the Meeting ID, your name, and the blue Join button. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, click on the button next to your name to virtually raise your hand and let us know you wish to speak. You will have 3 minutes. 3. Dialing in from a mobile phone or landline: Dial (669) 9009128. When prompted, enter the meeting ID. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, press *9 on your phone to virtually raise your hand. You will have 3 minutes. Submit a written comment You are invited to submit a written comment in one of the following ways: Email PBAecomments@santaana.org and reference the topic in the subject line. Mail to Nuvia Ocampo, Recording Secretary, City of Santa Ana, 20 Civic Center Plaza – M20, Santa Ana, CA 92701. Deadline to submit written comments is 4:00 p.m. on the day of the meeting.Comments received after the deadline may not be distributed to the Commission but will be made part of the record. Planning CommissionRegular Meeting AgendaMarch 25, 20245:30 P.M.Council Chamber22 Civic Center PlazaSanta Ana, CA Members of the public may attend this meeting inperson or join via Zoom.Join from your computer: https://zoom.us/j/84445428558Join from your mobile phone via Zoom App. Meeting ID: 84445428558Dial in from a mobile phone or landline.(669) 900 6833; Meeting ID: 84445428558*For viewing only: www.youtube.com/cityofsantaanavideos. Please note: There is up to a 30second delay when viewing the meeting via YouTube. If you plan to provide a public commentduring the meeting, please join the meeting via Zoom.For detailed participation and commenting options, please review the instructionsprovided at the end of this agenda.To download or view each item, select either Download PDF or View Item Details tothe right of the agenda title. BAO PHAMChair, Ward 1 RepresentativeJENNIFER OLIVAViceChairWard 6 Representative CHRISTOPHER LEOCitywide RepresentativeMANUEL J. ESCAMILLAWard 2 Representative CARL BENNINGERWard 4 RepresentativeISURI S. RAMOSWard 3 Representative ALAN WOOWard 5 RepresentativeMinh ThaiExecutive DirectorJose MontoyaLegal Counsel Ali Pezeshkpour, AICPPlanning Manager Nuvia OcampoRecording SecretaryIn compliance with the Americans with Disabilities Act (ADA), if you need special assistance to participate in this Meeting,contact Michael Ortiz, City ADA Program Coordinator, at (714) 6475624. Notification 48 hours prior to the Meeting will enablethe City to make reasonable arrangements to assure accessibility to this meeting. The City Council agenda and supportingdocumentation can be found on the City’s website – www.santaana.org/citymeetings.CALL TO ORDER Commissioners: Bao Pham, ChairManuel EscamillaChristopher LeoCarl BenningerJennifer OlivaIsuri S. RamosAlan Woo Executive Director Minh ThaiAssistant City Attorney Jose Montoya Planning Manager Ali Pezeshkpour, AICPRecording Secretary Nuvia OcampoROLL CALLPLEDGE OF ALLEGIANCEPUBLIC COMMENTSCONSENT CALENDAR ITEMSa.MinutesRecommended Action: Approve Minutes from March 11, 2024.b.Excused AbsencesRecommended Action: Excuse absent commissioners.*End of Consent Calendar*BUSINESS CALENDARPublic Hearing:The Planning Commission decision on Conditional Use Permits,Variances, Tentative Tract and Parcel Maps, Minor Exceptions, Site Plan Review, and Public Convenience or Necessity Determinations are final unless appealed within 10 days of the decision by any interested party or group (refer to the Basic Meeting Information page for more information). The Planning Commission recommendation on Zoning and General Plan amendments, Development Agreements, Specific Developments, and Specific Plans will be forwarded to the City Council for final determination. Legal notice was published in the OC Reporter on March 15, 2024 and notices were mailed on said date. 1.SITE PLAN REVIEW NO. 2024‐01 AND TENTATIVE TRACT MAP NO. 2024‐01 FOR THE PROPERTIES LOCATED AT 101, 111, 115, AND 121 NORTH HARBOR BOULEVARD, AT 3709 AND 3729 WEST FIRST STREET AND AT 114 NORTH FIGUEROA STREET, LOCATED WITHIN THE TRANSIT NODE SOUTH (TNS) DISTRICT OF THE HARBOR MIXED‐USE TRANSIT CORRIDOR SPECIFIC PLAN (SP‐2). Project Applicant: Charles Minyard with Primior, Inc. and representing Harbor and First, LLC. (Applicant & Property Owner) Proposed Project: Applicant is requesting approval of Site Plan Review (SPR) No. 202401 and Tentative Tract Map (TTM) No. 202401 to facilitate the construction of a mixeduse development known as First Harbor MixedUse Development, which would develop an existing vacant lot with a ninestory mixeduse building consisting of 15,182 square feet of leasable commercial space, 1,845 square feet of leasing office space, 181 forsale residential condominium units (including 10 onsite affordable units), 339 parking spaces, and 40,853 square feet of open space and amenities. Environmental Impact: Pursuant to the California Environment Quality Act (CEQA), the project is within the scope of the 2014 Harbor Boulevard MixedUse Transit Corridor Plan Environmental Impact Report (EIR) (SCH No. 2013061027). Recommended Actions: 1. Adopt a resolution approving Site Plan Review No. 202401 as conditioned. 2. Adopt a resolution approving Tentative Tract Map No. 202401 as conditioned. *End of Business Calendar* WORK STUDY SESSION Annual Budget Process – Shannon McCarron, Finance and Management Services *End of Work Study Session Calendar* STAFF COMMENTS COMMISSIONER COMMENTS ADJOURNMENT The next meeting of the Planning Commission will be on April 08, 2024 at 5:30 PM in the Council Chambers located at 22 Civic Center Plaza, Santa Ana, CA 92701. APPEAL INFORMATION The formal action by the Planning Commission shall become effective after the tenday appeal period, unless the City Council in compliance with section 41643, 41644 or 41645 holds a public hearing on the matter, then the formal action will become effective on the day following the hearing and decision by the City Council. An appeal from the decision or requirement of the Planning Commission may be made by any interested party, individual, or group. The appeal must be filed with the Clerk of the Council, accompanied by the required filing fee, and a copy sent to the Planning Department, within ten days of the date of the Commission's action, by 5:00 p.m. If the final day to appeal falls on a City Hall observed holiday or a day when City hall is closed, the final day to appeal shall be extended to the next day City Hall is open for public business. Please note: Under California Government Code Sec. 65009, if you challenge in court any of the matters on this agenda for which a public hearing is to be conducted, you may be limited to raising only those issues which you (or someone else) raised orally at the public hearing or in written correspondence received by the Planning Commission or City Council at or before the hearing. MEETING INFORMATION If you would like to learn how to use Zoom before the meeting, visit Zoom Video Tutorials. 1. Connecting directly from your computer: Click on the link on top of this agenda OR Go to Zoom.us and click "Join a Meeting" at the top. Enter the Meeting ID. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, click on the button next to your name to virtually raise your hand and let us know you wish to speak. You will have 3 minutes. 2. Connecting via the Zoom App: Download the free Zoom Cloud Meetings app from your favorite app store. Launch the app and click on the blue Join a Meeting button. Enter the Meeting ID, your name, and the blue Join button. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, click on the button next to your name to virtually raise your hand and let us know you wish to speak. You will have 3 minutes. 3. Dialing in from a mobile phone or landline: Dial (669) 9009128. When prompted, enter the meeting ID. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, press *9 on your phone to virtually raise your hand. You will have 3 minutes. Submit a written comment You are invited to submit a written comment in one of the following ways: Email PBAecomments@santaana.org and reference the topic in the subject line. Mail to Nuvia Ocampo, Recording Secretary, City of Santa Ana, 20 Civic Center Plaza – M20, Santa Ana, CA 92701. Deadline to submit written comments is 4:00 p.m. on the day of the meeting.Comments received after the deadline may not be distributed to the Commission but will be made part of the record. Planning CommissionRegular Meeting AgendaMarch 25, 20245:30 P.M.Council Chamber22 Civic Center PlazaSanta Ana, CA Members of the public may attend this meeting inperson or join via Zoom.Join from your computer: https://zoom.us/j/84445428558Join from your mobile phone via Zoom App. Meeting ID: 84445428558Dial in from a mobile phone or landline.(669) 900 6833; Meeting ID: 84445428558*For viewing only: www.youtube.com/cityofsantaanavideos. Please note: There is up to a 30second delay when viewing the meeting via YouTube. If you plan to provide a public commentduring the meeting, please join the meeting via Zoom.For detailed participation and commenting options, please review the instructionsprovided at the end of this agenda.To download or view each item, select either Download PDF or View Item Details tothe right of the agenda title. BAO PHAMChair, Ward 1 RepresentativeJENNIFER OLIVAViceChairWard 6 Representative CHRISTOPHER LEOCitywide RepresentativeMANUEL J. ESCAMILLAWard 2 Representative CARL BENNINGERWard 4 RepresentativeISURI S. RAMOSWard 3 Representative ALAN WOOWard 5 RepresentativeMinh ThaiExecutive DirectorJose MontoyaLegal Counsel Ali Pezeshkpour, AICPPlanning Manager Nuvia OcampoRecording SecretaryIn compliance with the Americans with Disabilities Act (ADA), if you need special assistance to participate in this Meeting,contact Michael Ortiz, City ADA Program Coordinator, at (714) 6475624. Notification 48 hours prior to the Meeting will enablethe City to make reasonable arrangements to assure accessibility to this meeting. The City Council agenda and supportingdocumentation can be found on the City’s website – www.santaana.org/citymeetings.CALL TO ORDER Commissioners: Bao Pham, ChairManuel EscamillaChristopher LeoCarl BenningerJennifer OlivaIsuri S. RamosAlan Woo Executive Director Minh ThaiAssistant City Attorney Jose Montoya Planning Manager Ali Pezeshkpour, AICPRecording Secretary Nuvia OcampoROLL CALLPLEDGE OF ALLEGIANCEPUBLIC COMMENTSCONSENT CALENDAR ITEMSa.MinutesRecommended Action: Approve Minutes from March 11, 2024.b.Excused AbsencesRecommended Action: Excuse absent commissioners.*End of Consent Calendar*BUSINESS CALENDARPublic Hearing:The Planning Commission decision on Conditional Use Permits,Variances, Tentative Tract and Parcel Maps, Minor Exceptions, Site Plan Review, andPublic Convenience or Necessity Determinations are final unless appealed within 10days of the decision by any interested party or group (refer to the Basic MeetingInformation page for more information). The Planning Commission recommendationon Zoning and General Plan amendments, Development Agreements, SpecificDevelopments, and Specific Plans will be forwarded to the City Council for finaldetermination. Legal notice was published in the OC Reporter on March 15, 2024 andnotices were mailed on said date. 1.SITE PLAN REVIEW NO. 2024‐01 AND TENTATIVE TRACT MAP NO. 2024‐01 FOR THEPROPERTIES LOCATED AT 101, 111, 115, AND 121 NORTH HARBOR BOULEVARD, AT 3709 AND3729 WEST FIRST STREET AND AT 114 NORTH FIGUEROA STREET, LOCATED WITHIN THETRANSIT NODE SOUTH (TNS) DISTRICT OF THE HARBOR MIXED‐USE TRANSIT CORRIDORSPECIFIC PLAN (SP‐2).Project Applicant: Charles Minyard with Primior, Inc. and representing Harbor andFirst, LLC. (Applicant & Property Owner)Proposed Project: Applicant is requesting approval of Site Plan Review (SPR) No.202401 and Tentative Tract Map (TTM) No. 202401 to facilitate the construction of amixeduse development known as First Harbor MixedUse Development, whichwould develop an existing vacant lot with a ninestory mixeduse building consisting of15,182 square feet of leasable commercial space, 1,845 square feet of leasing officespace, 181 forsale residential condominium units (including 10 onsite affordable units),339 parking spaces, and 40,853 square feet of open space and amenities.Environmental Impact: Pursuant to the California Environment Quality Act (CEQA),the project is within the scope of the 2014 Harbor Boulevard MixedUse Transit CorridorPlan Environmental Impact Report (EIR) (SCH No. 2013061027).Recommended Actions:1. Adopt a resolution approving Site Plan Review No. 202401 as conditioned.2. Adopt a resolution approving Tentative Tract Map No. 202401 as conditioned.*End of Business Calendar*WORK STUDY SESSION Annual Budget Process – Shannon McCarron, Finance and Management Services*End of Work Study Session Calendar*STAFF COMMENTSCOMMISSIONER COMMENTSADJOURNMENTThe next meeting of the Planning Commission will be on April 08, 2024 at 5:30 PM in theCouncil Chambers located at 22 Civic Center Plaza, Santa Ana, CA 92701.APPEAL INFORMATION The formal action by the Planning Commission shall become effective after the tenday appeal period, unless the City Council in compliance with section 41643, 41644 or 41645 holds a public hearing on the matter, then the formal action will become effective on the day following the hearing and decision by the City Council. An appeal from the decision or requirement of the Planning Commission may be made by any interested party, individual, or group. The appeal must be filed with the Clerk of the Council, accompanied by the required filing fee, and a copy sent to the Planning Department, within ten days of the date of the Commission's action, by 5:00 p.m. If the final day to appeal falls on a City Hall observed holiday or a day when City hall is closed, the final day to appeal shall be extended to the next day City Hall is open for public business. Please note: Under California Government Code Sec. 65009, if you challenge in court any of the matters on this agenda for which a public hearing is to be conducted, you may be limited to raising only those issues which you (or someone else) raised orally at the public hearing or in written correspondence received by the Planning Commission or City Council at or before the hearing. MEETING INFORMATION If you would like to learn how to use Zoom before the meeting, visit Zoom Video Tutorials. 1. Connecting directly from your computer: Click on the link on top of this agenda OR Go to Zoom.us and click "Join a Meeting" at the top. Enter the Meeting ID. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, click on the button next to your name to virtually raise your hand and let us know you wish to speak. You will have 3 minutes. 2. Connecting via the Zoom App: Download the free Zoom Cloud Meetings app from your favorite app store. Launch the app and click on the blue Join a Meeting button. Enter the Meeting ID, your name, and the blue Join button. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, click on the button next to your name to virtually raise your hand and let us know you wish to speak. You will have 3 minutes. 3. Dialing in from a mobile phone or landline: Dial (669) 9009128. When prompted, enter the meeting ID. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, press *9 on your phone to virtually raise your hand. You will have 3 minutes. Submit a written comment You are invited to submit a written comment in one of the following ways: Email PBAecomments@santaana.org and reference the topic in the subject line. Mail to Nuvia Ocampo, Recording Secretary, City of Santa Ana, 20 Civic Center Plaza – M20, Santa Ana, CA 92701. Deadline to submit written comments is 4:00 p.m. on the day of the meeting.Comments received after the deadline may not be distributed to the Commission but will be made part of the record. Planning CommissionRegular Meeting AgendaMarch 25, 20245:30 P.M.Council Chamber22 Civic Center PlazaSanta Ana, CA Members of the public may attend this meeting inperson or join via Zoom.Join from your computer: https://zoom.us/j/84445428558Join from your mobile phone via Zoom App. Meeting ID: 84445428558Dial in from a mobile phone or landline.(669) 900 6833; Meeting ID: 84445428558*For viewing only: www.youtube.com/cityofsantaanavideos. Please note: There is up to a 30second delay when viewing the meeting via YouTube. If you plan to provide a public commentduring the meeting, please join the meeting via Zoom.For detailed participation and commenting options, please review the instructionsprovided at the end of this agenda.To download or view each item, select either Download PDF or View Item Details tothe right of the agenda title. BAO PHAMChair, Ward 1 RepresentativeJENNIFER OLIVAViceChairWard 6 Representative CHRISTOPHER LEOCitywide RepresentativeMANUEL J. ESCAMILLAWard 2 Representative CARL BENNINGERWard 4 RepresentativeISURI S. RAMOSWard 3 Representative ALAN WOOWard 5 RepresentativeMinh ThaiExecutive DirectorJose MontoyaLegal Counsel Ali Pezeshkpour, AICPPlanning Manager Nuvia OcampoRecording SecretaryIn compliance with the Americans with Disabilities Act (ADA), if you need special assistance to participate in this Meeting,contact Michael Ortiz, City ADA Program Coordinator, at (714) 6475624. Notification 48 hours prior to the Meeting will enablethe City to make reasonable arrangements to assure accessibility to this meeting. The City Council agenda and supportingdocumentation can be found on the City’s website – www.santaana.org/citymeetings.CALL TO ORDER Commissioners: Bao Pham, ChairManuel EscamillaChristopher LeoCarl BenningerJennifer OlivaIsuri S. RamosAlan Woo Executive Director Minh ThaiAssistant City Attorney Jose Montoya Planning Manager Ali Pezeshkpour, AICPRecording Secretary Nuvia OcampoROLL CALLPLEDGE OF ALLEGIANCEPUBLIC COMMENTSCONSENT CALENDAR ITEMSa.MinutesRecommended Action: Approve Minutes from March 11, 2024.b.Excused AbsencesRecommended Action: Excuse absent commissioners.*End of Consent Calendar*BUSINESS CALENDARPublic Hearing:The Planning Commission decision on Conditional Use Permits,Variances, Tentative Tract and Parcel Maps, Minor Exceptions, Site Plan Review, andPublic Convenience or Necessity Determinations are final unless appealed within 10days of the decision by any interested party or group (refer to the Basic MeetingInformation page for more information). The Planning Commission recommendationon Zoning and General Plan amendments, Development Agreements, SpecificDevelopments, and Specific Plans will be forwarded to the City Council for finaldetermination. Legal notice was published in the OC Reporter on March 15, 2024 andnotices were mailed on said date. 1.SITE PLAN REVIEW NO. 2024‐01 AND TENTATIVE TRACT MAP NO. 2024‐01 FOR THEPROPERTIES LOCATED AT 101, 111, 115, AND 121 NORTH HARBOR BOULEVARD, AT 3709 AND3729 WEST FIRST STREET AND AT 114 NORTH FIGUEROA STREET, LOCATED WITHIN THETRANSIT NODE SOUTH (TNS) DISTRICT OF THE HARBOR MIXED‐USE TRANSIT CORRIDORSPECIFIC PLAN (SP‐2).Project Applicant: Charles Minyard with Primior, Inc. and representing Harbor andFirst, LLC. (Applicant & Property Owner)Proposed Project: Applicant is requesting approval of Site Plan Review (SPR) No.202401 and Tentative Tract Map (TTM) No. 202401 to facilitate the construction of amixeduse development known as First Harbor MixedUse Development, whichwould develop an existing vacant lot with a ninestory mixeduse building consisting of15,182 square feet of leasable commercial space, 1,845 square feet of leasing officespace, 181 forsale residential condominium units (including 10 onsite affordable units),339 parking spaces, and 40,853 square feet of open space and amenities.Environmental Impact: Pursuant to the California Environment Quality Act (CEQA),the project is within the scope of the 2014 Harbor Boulevard MixedUse Transit CorridorPlan Environmental Impact Report (EIR) (SCH No. 2013061027).Recommended Actions:1. Adopt a resolution approving Site Plan Review No. 202401 as conditioned.2. Adopt a resolution approving Tentative Tract Map No. 202401 as conditioned.*End of Business Calendar*WORK STUDY SESSION Annual Budget Process – Shannon McCarron, Finance and Management Services*End of Work Study Session Calendar*STAFF COMMENTSCOMMISSIONER COMMENTSADJOURNMENTThe next meeting of the Planning Commission will be on April 08, 2024 at 5:30 PM in theCouncil Chambers located at 22 Civic Center Plaza, Santa Ana, CA 92701.APPEAL INFORMATIONThe formal action by the Planning Commission shall become effective after the tendayappeal period, unless the City Council in compliance with section 41643, 41644 or 41645holds a public hearing on the matter, then the formal action will become effective on the dayfollowing the hearing and decision by the City Council. An appeal from the decision orrequirement of the Planning Commission may be made by any interested party, individual, orgroup. The appeal must be filed with the Clerk of the Council, accompanied by the requiredfiling fee, and a copy sent to the Planning Department, within ten days of the date of theCommission's action, by 5:00 p.m. If the final day to appeal falls on a City Hall observedholiday or a day when City hall is closed, the final day to appeal shall be extended to the nextday City Hall is open for public business. Please note: Under California Government CodeSec. 65009, if you challenge in court any of the matters on this agenda for which a publichearing is to be conducted, you may be limited to raising only those issues which you (orsomeone else) raised orally at the public hearing or in written correspondence received bythe Planning Commission or City Council at or before the hearing.MEETING INFORMATIONIf you would like to learn how to use Zoom before the meeting, visit Zoom Video Tutorials.1. Connecting directly from your computer:Click on the link on top of this agenda ORGo to Zoom.us and click "Join a Meeting" at the top. Enter the Meeting ID. The MeetingID is listed at the top of this agenda.To speak during the meeting: When you wish to comment on an item that is being isdiscussed, click on the button next to your name to virtually raise your hand and let us knowyou wish to speak. You will have 3 minutes.2. Connecting via the Zoom App:Download the free Zoom Cloud Meetings app from your favorite app store.Launch the app and click on the blue Join a Meeting button. Enter the Meeting ID, yourname, and the blue Join button. The Meeting ID is listed at the top of this agenda.To speak during the meeting: When you wish to comment on an item that is being isdiscussed, click on the button next to your name to virtually raise your hand and let us knowyou wish to speak. You will have 3 minutes.3. Dialing in from a mobile phone or landline:Dial (669) 9009128. When prompted, enter the meeting ID. The Meeting ID is listed atthe top of this agenda.To speak during the meeting: When you wish to comment on an item that is being isdiscussed, press *9 on your phone to virtually raise your hand. You will have 3 minutes. Submit a written comment You are invited to submit a written comment in one of the following ways: Email PBAecomments@santaana.org and reference the topic in the subject line. Mail to Nuvia Ocampo, Recording Secretary, City of Santa Ana, 20 Civic Center Plaza – M20, Santa Ana, CA 92701. Deadline to submit written comments is 4:00 p.m. on the day of the meeting.Comments received after the deadline may not be distributed to the Commission but will be made part of the record. Planning Commission Regular Meeting Agenda Minutes March 11, 2024 5:30 P.M. Council Chamber 22 Civic Center Plaza Santa Ana, CA BAO PHAM Chair, Ward 1 Representative JENNIFER OLIVA ViceChair, Ward 6 Representative CHRISTOPHER LEO Citywide Representative MANUEL J. ESCAMILLA Ward 2 Representative CARL BENNINGER Ward 4 Representative ISURI S. RAMOS Ward 3 Representative ALAN WOO Ward 5 Representative Minh Thai Executive Director Jose Montoya Legal Counsel Ali Pezeshkpour, AICP Planning Manager Nuvia Ocampo Recording Secretary In compliance with the Americans with Disabilities Act (ADA), if you need special assistance to participate in this Meeting, contact Michael Ortiz, City ADA Program Coordinator, at (714) 6475624. Notification 48 hours prior to the Meeting will enable the City to make reasonable arrangements to assure accessibility to this meeting. The City Council agenda and supporting documentation can be found on the City’s website – www.santaana.org/citymeetings. CALL TO ORDER Commissioners: Bao Pham, Chair Manuel Escamilla Christopher Leo Carl Benninger Jennifer Oliva Isuri S. Ramos Alan Woo Executive Director Minh Thai Assistant City Attorney Jose Montoya Planning Manager Ali Pezeshkpour, AICP Recording Secretary Nuvia Ocampo ROLL CALL Minutes: Quorum was reached at 5:31 p.m. with Commissioner Escamilla arriving at 5:41 p.m. and Commissioner Ramos arriving at 5:43 p.m. PLEDGE OF ALLEGIANCE PUBLIC COMMENTS CONSENT CALENDAR ITEMS a.Minutes Recommended Action: Approve Minutes from February 26, 2024. b.Excused Absences Recommended Action: Excuse absent commissioners. Minutes: Commissioner Leo abstained from voting as he was absent at the February 26, 2024 meeting. Moved by Commissioner Woo, seconded by Commissioner Benninger to Approve Consent Calendar items. YES: 3 – Bao Pham, Alan Woo, Carl Benninger NO: 0 – ABSTAIN: 1 – Christopher Leo ABSENT: 3 – Isuri Ramos, Manuel J. Escamilla, Jennifer Oliva Status: 3 – 0 – 1 – 3 – Pass *End of Consent Calendar* BUSINESS CALENDAR NO PUBLIC HEARING ITEMS. *End of Business Calendar* WORK STUDY SESSION 1.Proposed Zoning Code Amendments Addressing Electrified Security Fences. Minutes: Applicant, Keith Kaneco, had comments for the Commission. *End of Work Study Session Calendar* STAFF COMMENTS Minutes: None COMMISSIONER COMMENTS Minutes: Commission had comments for staff. ADJOURNMENT The next meeting of the Planning Commission will be on March 25, 2024 at 5:30 PM in the Council Chambers located at 22 Civic Center Plaza, Santa Ana, CA 92701. Minutes: Meeting was adjourned at 6:29 p.m. APPEAL INFORMATION The formal action by the Planning Commission shall become effective after the tenday appeal period, unless the City Council in compliance with section 41643, 41644 or 41645 holds a public hearing on the matter, then the formal action will become effective on the day following the hearing and decision by the City Council. An appeal from the decision or requirement of the Planning Commission may be made by any interested party, individual, or group. The appeal must be filed with the Clerk of the Council, accompanied by the required filing fee, and a copy sent to the Planning Department, within ten days of the date of the Commission's action, by 5:00 p.m. If the final day to appeal falls on a City Hall observed holiday or a day when City hall is closed, the final day to appeal shall be extended to the next day City Hall is open for public business. Please note: Under California Government Code Sec. 65009, if you challenge in court any of the matters on this agenda for which a public hearing is to be conducted, you may be limited to raising only those issues which you (or someone else) raised orally at the public hearing or in written correspondence received by the Planning Commission or City Council at or before the hearing. MEETING INFORMATION If you would like to learn how to use Zoom before the meeting, visit Zoom Video Tutorials. 1. Connecting directly from your computer: Click on the link on top of this agenda OR Go to Zoom.us and click "Join a Meeting" at the top. Enter the Meeting ID. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, click on the button next to your name to virtually raise your hand and let us know you wish to speak. You will have 3 minutes. 2. Connecting via the Zoom App: Download the free Zoom Cloud Meetings app from your favorite app store. Launch the app and click on the blue Join a Meeting button. Enter the Meeting ID, your name, and the blue Join button. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, click on the button next to your name to virtually raise your hand and let us know you wish to speak. You will have 3 minutes. 3. Dialing in from a mobile phone or landline: Dial (669) 9009128. When prompted, enter the meeting ID. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, press *9 on your phone to virtually raise your hand. You will have 3 minutes. Submit a written comment You are invited to submit a written comment in one of the following ways: Email PBAecomments@santaana.org and reference the topic in the subject line. Mail to Nuvia Ocampo, Recording Secretary, City of Santa Ana, 20 Civic Center Plaza – M20, Santa Ana, CA 92701. Deadline to submit written comments is 4:00 p.m. on the day of the meeting.Comments received after the deadline may not be distributed to the Commission but will be made part of the record. 1 Planning Commission 3/11/2024 Planning CommissionRegular Meeting Agenda MinutesMarch 11, 20245:30 P.M.Council Chamber22 Civic Center PlazaSanta Ana, CA BAO PHAMChair, Ward 1 RepresentativeJENNIFER OLIVAViceChair,Ward 6 Representative CHRISTOPHER LEOCitywide RepresentativeMANUEL J. ESCAMILLAWard 2 Representative CARL BENNINGERWard 4 RepresentativeISURI S. RAMOSWard 3 Representative ALAN WOOWard 5 RepresentativeMinh ThaiExecutive DirectorJose MontoyaLegal Counsel Ali Pezeshkpour, AICPPlanning Manager Nuvia OcampoRecording Secretary In compliance with the Americans with Disabilities Act (ADA), if you need special assistance to participate in this Meeting, contact Michael Ortiz, City ADA Program Coordinator, at (714) 6475624. Notification 48 hours prior to the Meeting will enable the City to make reasonable arrangements to assure accessibility to this meeting. The City Council agenda and supporting documentation can be found on the City’s website – www.santaana.org/citymeetings. CALL TO ORDER Commissioners: Bao Pham, Chair Manuel Escamilla Christopher Leo Carl Benninger Jennifer Oliva Isuri S. Ramos Alan Woo Executive Director Minh Thai Assistant City Attorney Jose Montoya Planning Manager Ali Pezeshkpour, AICP Recording Secretary Nuvia Ocampo ROLL CALL Minutes: Quorum was reached at 5:31 p.m. with Commissioner Escamilla arriving at 5:41 p.m. and Commissioner Ramos arriving at 5:43 p.m. PLEDGE OF ALLEGIANCE PUBLIC COMMENTS CONSENT CALENDAR ITEMS a.Minutes Recommended Action: Approve Minutes from February 26, 2024. b.Excused Absences Recommended Action: Excuse absent commissioners. Minutes: Commissioner Leo abstained from voting as he was absent at the February 26, 2024 meeting. Moved by Commissioner Woo, seconded by Commissioner Benninger to Approve Consent Calendar items. YES: 3 – Bao Pham, Alan Woo, Carl Benninger NO: 0 – ABSTAIN: 1 – Christopher Leo ABSENT: 3 – Isuri Ramos, Manuel J. Escamilla, Jennifer Oliva Status: 3 – 0 – 1 – 3 – Pass *End of Consent Calendar* BUSINESS CALENDAR NO PUBLIC HEARING ITEMS. *End of Business Calendar* WORK STUDY SESSION 1.Proposed Zoning Code Amendments Addressing Electrified Security Fences. Minutes: Applicant, Keith Kaneco, had comments for the Commission. *End of Work Study Session Calendar* STAFF COMMENTS Minutes: None COMMISSIONER COMMENTS Minutes: Commission had comments for staff. ADJOURNMENT The next meeting of the Planning Commission will be on March 25, 2024 at 5:30 PM in the Council Chambers located at 22 Civic Center Plaza, Santa Ana, CA 92701. Minutes: Meeting was adjourned at 6:29 p.m. APPEAL INFORMATION The formal action by the Planning Commission shall become effective after the tenday appeal period, unless the City Council in compliance with section 41643, 41644 or 41645 holds a public hearing on the matter, then the formal action will become effective on the day following the hearing and decision by the City Council. An appeal from the decision or requirement of the Planning Commission may be made by any interested party, individual, or group. The appeal must be filed with the Clerk of the Council, accompanied by the required filing fee, and a copy sent to the Planning Department, within ten days of the date of the Commission's action, by 5:00 p.m. If the final day to appeal falls on a City Hall observed holiday or a day when City hall is closed, the final day to appeal shall be extended to the next day City Hall is open for public business. Please note: Under California Government Code Sec. 65009, if you challenge in court any of the matters on this agenda for which a public hearing is to be conducted, you may be limited to raising only those issues which you (or someone else) raised orally at the public hearing or in written correspondence received by the Planning Commission or City Council at or before the hearing. MEETING INFORMATION If you would like to learn how to use Zoom before the meeting, visit Zoom Video Tutorials. 1. Connecting directly from your computer: Click on the link on top of this agenda OR Go to Zoom.us and click "Join a Meeting" at the top. Enter the Meeting ID. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, click on the button next to your name to virtually raise your hand and let us know you wish to speak. You will have 3 minutes. 2. Connecting via the Zoom App: Download the free Zoom Cloud Meetings app from your favorite app store. Launch the app and click on the blue Join a Meeting button. Enter the Meeting ID, your name, and the blue Join button. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, click on the button next to your name to virtually raise your hand and let us know you wish to speak. You will have 3 minutes. 3. Dialing in from a mobile phone or landline: Dial (669) 9009128. When prompted, enter the meeting ID. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, press *9 on your phone to virtually raise your hand. You will have 3 minutes. Submit a written comment You are invited to submit a written comment in one of the following ways: Email PBAecomments@santaana.org and reference the topic in the subject line. Mail to Nuvia Ocampo, Recording Secretary, City of Santa Ana, 20 Civic Center Plaza – M20, Santa Ana, CA 92701. Deadline to submit written comments is 4:00 p.m. on the day of the meeting.Comments received after the deadline may not be distributed to the Commission but will be made part of the record. 2 Planning Commission 3/11/2024 Planning CommissionRegular Meeting Agenda MinutesMarch 11, 20245:30 P.M.Council Chamber22 Civic Center PlazaSanta Ana, CA BAO PHAMChair, Ward 1 RepresentativeJENNIFER OLIVAViceChair,Ward 6 Representative CHRISTOPHER LEOCitywide RepresentativeMANUEL J. ESCAMILLAWard 2 Representative CARL BENNINGERWard 4 RepresentativeISURI S. RAMOSWard 3 Representative ALAN WOOWard 5 RepresentativeMinh ThaiExecutive DirectorJose MontoyaLegal Counsel Ali Pezeshkpour, AICPPlanning Manager Nuvia OcampoRecording SecretaryIn compliance with the Americans with Disabilities Act (ADA), if you need special assistance to participate in this Meeting,contact Michael Ortiz, City ADA Program Coordinator, at (714) 6475624. Notification 48 hours prior to the Meeting will enablethe City to make reasonable arrangements to assure accessibility to this meeting. The City Council agenda and supportingdocumentation can be found on the City’s website – www.santaana.org/citymeetings.CALL TO ORDER Commissioners: Bao Pham, ChairManuel EscamillaChristopher LeoCarl Benninger Jennifer OlivaIsuri S. RamosAlan Woo Executive Director Minh ThaiAssistant City Attorney Jose Montoya Planning Manager Ali Pezeshkpour, AICPRecording Secretary Nuvia OcampoROLL CALLMinutes: Quorum was reached at 5:31 p.m. with Commissioner Escamilla arriving at 5:41p.m. and Commissioner Ramos arriving at 5:43 p.m.PLEDGE OF ALLEGIANCEPUBLIC COMMENTSCONSENT CALENDAR ITEMSa.MinutesRecommended Action: Approve Minutes from February 26, 2024.b.Excused AbsencesRecommended Action: Excuse absent commissioners.Minutes: Commissioner Leo abstained from voting as he was absent at the February 26,2024 meeting. Moved by Commissioner Woo, seconded by Commissioner Benninger to Approve Consent Calendar items. YES: 3 – Bao Pham, Alan Woo, Carl Benninger NO: 0 – ABSTAIN: 1 – Christopher Leo ABSENT: 3 – Isuri Ramos, Manuel J. Escamilla, Jennifer Oliva Status: 3 – 0 – 1 – 3 – Pass *End of Consent Calendar* BUSINESS CALENDAR NO PUBLIC HEARING ITEMS. *End of Business Calendar* WORK STUDY SESSION 1.Proposed Zoning Code Amendments Addressing Electrified Security Fences. Minutes: Applicant, Keith Kaneco, had comments for the Commission. *End of Work Study Session Calendar* STAFF COMMENTS Minutes: None COMMISSIONER COMMENTS Minutes: Commission had comments for staff. ADJOURNMENT The next meeting of the Planning Commission will be on March 25, 2024 at 5:30 PM in the Council Chambers located at 22 Civic Center Plaza, Santa Ana, CA 92701. Minutes: Meeting was adjourned at 6:29 p.m. APPEAL INFORMATION The formal action by the Planning Commission shall become effective after the tenday appeal period, unless the City Council in compliance with section 41643, 41644 or 41645 holds a public hearing on the matter, then the formal action will become effective on the day following the hearing and decision by the City Council. An appeal from the decision or requirement of the Planning Commission may be made by any interested party, individual, or group. The appeal must be filed with the Clerk of the Council, accompanied by the required filing fee, and a copy sent to the Planning Department, within ten days of the date of the Commission's action, by 5:00 p.m. If the final day to appeal falls on a City Hall observed holiday or a day when City hall is closed, the final day to appeal shall be extended to the next day City Hall is open for public business. Please note: Under California Government Code Sec. 65009, if you challenge in court any of the matters on this agenda for which a public hearing is to be conducted, you may be limited to raising only those issues which you (or someone else) raised orally at the public hearing or in written correspondence received by the Planning Commission or City Council at or before the hearing. MEETING INFORMATION If you would like to learn how to use Zoom before the meeting, visit Zoom Video Tutorials. 1. Connecting directly from your computer: Click on the link on top of this agenda OR Go to Zoom.us and click "Join a Meeting" at the top. Enter the Meeting ID. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, click on the button next to your name to virtually raise your hand and let us know you wish to speak. You will have 3 minutes. 2. Connecting via the Zoom App: Download the free Zoom Cloud Meetings app from your favorite app store. Launch the app and click on the blue Join a Meeting button. Enter the Meeting ID, your name, and the blue Join button. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, click on the button next to your name to virtually raise your hand and let us know you wish to speak. You will have 3 minutes. 3. Dialing in from a mobile phone or landline: Dial (669) 9009128. When prompted, enter the meeting ID. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, press *9 on your phone to virtually raise your hand. You will have 3 minutes. Submit a written comment You are invited to submit a written comment in one of the following ways: Email PBAecomments@santaana.org and reference the topic in the subject line. Mail to Nuvia Ocampo, Recording Secretary, City of Santa Ana, 20 Civic Center Plaza – M20, Santa Ana, CA 92701. Deadline to submit written comments is 4:00 p.m. on the day of the meeting.Comments received after the deadline may not be distributed to the Commission but will be made part of the record. 3 Planning Commission 3/11/2024 Planning CommissionRegular Meeting Agenda MinutesMarch 11, 20245:30 P.M.Council Chamber22 Civic Center PlazaSanta Ana, CA BAO PHAMChair, Ward 1 RepresentativeJENNIFER OLIVAViceChair,Ward 6 Representative CHRISTOPHER LEOCitywide RepresentativeMANUEL J. ESCAMILLAWard 2 Representative CARL BENNINGERWard 4 RepresentativeISURI S. RAMOSWard 3 Representative ALAN WOOWard 5 RepresentativeMinh ThaiExecutive DirectorJose MontoyaLegal Counsel Ali Pezeshkpour, AICPPlanning Manager Nuvia OcampoRecording SecretaryIn compliance with the Americans with Disabilities Act (ADA), if you need special assistance to participate in this Meeting,contact Michael Ortiz, City ADA Program Coordinator, at (714) 6475624. Notification 48 hours prior to the Meeting will enablethe City to make reasonable arrangements to assure accessibility to this meeting. The City Council agenda and supportingdocumentation can be found on the City’s website – www.santaana.org/citymeetings.CALL TO ORDER Commissioners: Bao Pham, ChairManuel EscamillaChristopher LeoCarl Benninger Jennifer OlivaIsuri S. RamosAlan Woo Executive Director Minh ThaiAssistant City Attorney Jose Montoya Planning Manager Ali Pezeshkpour, AICPRecording Secretary Nuvia OcampoROLL CALLMinutes: Quorum was reached at 5:31 p.m. with Commissioner Escamilla arriving at 5:41p.m. and Commissioner Ramos arriving at 5:43 p.m.PLEDGE OF ALLEGIANCEPUBLIC COMMENTSCONSENT CALENDAR ITEMSa.MinutesRecommended Action: Approve Minutes from February 26, 2024.b.Excused AbsencesRecommended Action: Excuse absent commissioners.Minutes: Commissioner Leo abstained from voting as he was absent at the February 26,2024 meeting.Moved by Commissioner Woo, seconded by Commissioner Benninger to ApproveConsent Calendar items.YES: 3 – Bao Pham, Alan Woo, Carl BenningerNO: 0 – ABSTAIN: 1 – Christopher LeoABSENT: 3 – Isuri Ramos, Manuel J. Escamilla, Jennifer OlivaStatus: 3 – 0 – 1 – 3 – Pass*End of Consent Calendar*BUSINESS CALENDARNO PUBLIC HEARING ITEMS.*End of Business Calendar*WORK STUDY SESSION1.Proposed Zoning Code Amendments Addressing Electrified Security Fences.Minutes: Applicant, Keith Kaneco, had comments for the Commission. *End of Work Study Session Calendar*STAFF COMMENTSMinutes: NoneCOMMISSIONER COMMENTSMinutes: Commission had comments for staff. ADJOURNMENTThe next meeting of the Planning Commission will be on March 25, 2024 at 5:30 PM in theCouncil Chambers located at 22 Civic Center Plaza, Santa Ana, CA 92701.Minutes: Meeting was adjourned at 6:29 p.m.APPEAL INFORMATIONThe formal action by the Planning Commission shall become effective after the tendayappeal period, unless the City Council in compliance with section 41643, 41644 or 41645holds a public hearing on the matter, then the formal action will become effective on the dayfollowing the hearing and decision by the City Council. An appeal from the decision orrequirement of the Planning Commission may be made by any interested party, individual, orgroup. The appeal must be filed with the Clerk of the Council, accompanied by the requiredfiling fee, and a copy sent to the Planning Department, within ten days of the date of theCommission's action, by 5:00 p.m. If the final day to appeal falls on a City Hall observedholiday or a day when City hall is closed, the final day to appeal shall be extended to the next day City Hall is open for public business. Please note: Under California Government Code Sec. 65009, if you challenge in court any of the matters on this agenda for which a public hearing is to be conducted, you may be limited to raising only those issues which you (or someone else) raised orally at the public hearing or in written correspondence received by the Planning Commission or City Council at or before the hearing. MEETING INFORMATION If you would like to learn how to use Zoom before the meeting, visit Zoom Video Tutorials. 1. Connecting directly from your computer: Click on the link on top of this agenda OR Go to Zoom.us and click "Join a Meeting" at the top. Enter the Meeting ID. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, click on the button next to your name to virtually raise your hand and let us know you wish to speak. You will have 3 minutes. 2. Connecting via the Zoom App: Download the free Zoom Cloud Meetings app from your favorite app store. Launch the app and click on the blue Join a Meeting button. Enter the Meeting ID, your name, and the blue Join button. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, click on the button next to your name to virtually raise your hand and let us know you wish to speak. You will have 3 minutes. 3. Dialing in from a mobile phone or landline: Dial (669) 9009128. When prompted, enter the meeting ID. The Meeting ID is listed at the top of this agenda. To speak during the meeting: When you wish to comment on an item that is being is discussed, press *9 on your phone to virtually raise your hand. You will have 3 minutes. Submit a written comment You are invited to submit a written comment in one of the following ways: Email PBAecomments@santaana.org and reference the topic in the subject line. Mail to Nuvia Ocampo, Recording Secretary, City of Santa Ana, 20 Civic Center Plaza – M20, Santa Ana, CA 92701. Deadline to submit written comments is 4:00 p.m. on the day of the meeting.Comments received after the deadline may not be distributed to the Commission but will be made part of the record. 4 Planning Commission 3/11/2024 Planning CommissionRegular Meeting Agenda MinutesMarch 11, 20245:30 P.M.Council Chamber22 Civic Center PlazaSanta Ana, CA BAO PHAMChair, Ward 1 RepresentativeJENNIFER OLIVAViceChair,Ward 6 Representative CHRISTOPHER LEOCitywide RepresentativeMANUEL J. ESCAMILLAWard 2 Representative CARL BENNINGERWard 4 RepresentativeISURI S. RAMOSWard 3 Representative ALAN WOOWard 5 RepresentativeMinh ThaiExecutive DirectorJose MontoyaLegal Counsel Ali Pezeshkpour, AICPPlanning Manager Nuvia OcampoRecording SecretaryIn compliance with the Americans with Disabilities Act (ADA), if you need special assistance to participate in this Meeting,contact Michael Ortiz, City ADA Program Coordinator, at (714) 6475624. Notification 48 hours prior to the Meeting will enablethe City to make reasonable arrangements to assure accessibility to this meeting. The City Council agenda and supportingdocumentation can be found on the City’s website – www.santaana.org/citymeetings.CALL TO ORDER Commissioners: Bao Pham, ChairManuel EscamillaChristopher LeoCarl Benninger Jennifer OlivaIsuri S. RamosAlan Woo Executive Director Minh ThaiAssistant City Attorney Jose Montoya Planning Manager Ali Pezeshkpour, AICPRecording Secretary Nuvia OcampoROLL CALLMinutes: Quorum was reached at 5:31 p.m. with Commissioner Escamilla arriving at 5:41p.m. and Commissioner Ramos arriving at 5:43 p.m.PLEDGE OF ALLEGIANCEPUBLIC COMMENTSCONSENT CALENDAR ITEMSa.MinutesRecommended Action: Approve Minutes from February 26, 2024.b.Excused AbsencesRecommended Action: Excuse absent commissioners.Minutes: Commissioner Leo abstained from voting as he was absent at the February 26,2024 meeting.Moved by Commissioner Woo, seconded by Commissioner Benninger to ApproveConsent Calendar items.YES: 3 – Bao Pham, Alan Woo, Carl BenningerNO: 0 – ABSTAIN: 1 – Christopher LeoABSENT: 3 – Isuri Ramos, Manuel J. Escamilla, Jennifer OlivaStatus: 3 – 0 – 1 – 3 – Pass*End of Consent Calendar*BUSINESS CALENDARNO PUBLIC HEARING ITEMS.*End of Business Calendar*WORK STUDY SESSION1.Proposed Zoning Code Amendments Addressing Electrified Security Fences.Minutes: Applicant, Keith Kaneco, had comments for the Commission. *End of Work Study Session Calendar*STAFF COMMENTSMinutes: NoneCOMMISSIONER COMMENTSMinutes: Commission had comments for staff. ADJOURNMENTThe next meeting of the Planning Commission will be on March 25, 2024 at 5:30 PM in theCouncil Chambers located at 22 Civic Center Plaza, Santa Ana, CA 92701.Minutes: Meeting was adjourned at 6:29 p.m.APPEAL INFORMATIONThe formal action by the Planning Commission shall become effective after the tendayappeal period, unless the City Council in compliance with section 41643, 41644 or 41645holds a public hearing on the matter, then the formal action will become effective on the dayfollowing the hearing and decision by the City Council. An appeal from the decision orrequirement of the Planning Commission may be made by any interested party, individual, orgroup. The appeal must be filed with the Clerk of the Council, accompanied by the requiredfiling fee, and a copy sent to the Planning Department, within ten days of the date of theCommission's action, by 5:00 p.m. If the final day to appeal falls on a City Hall observedholiday or a day when City hall is closed, the final day to appeal shall be extended to the nextday City Hall is open for public business. Please note: Under California Government CodeSec. 65009, if you challenge in court any of the matters on this agenda for which a publichearing is to be conducted, you may be limited to raising only those issues which you (orsomeone else) raised orally at the public hearing or in written correspondence received bythe Planning Commission or City Council at or before the hearing.MEETING INFORMATIONIf you would like to learn how to use Zoom before the meeting, visit Zoom Video Tutorials.1. Connecting directly from your computer:Click on the link on top of this agenda ORGo to Zoom.us and click "Join a Meeting" at the top. Enter the Meeting ID. The MeetingID is listed at the top of this agenda.To speak during the meeting: When you wish to comment on an item that is being isdiscussed, click on the button next to your name to virtually raise your hand and let us knowyou wish to speak. You will have 3 minutes.2. Connecting via the Zoom App:Download the free Zoom Cloud Meetings app from your favorite app store.Launch the app and click on the blue Join a Meeting button. Enter the Meeting ID, yourname, and the blue Join button. The Meeting ID is listed at the top of this agenda.To speak during the meeting: When you wish to comment on an item that is being isdiscussed, click on the button next to your name to virtually raise your hand and let us knowyou wish to speak. You will have 3 minutes.3. Dialing in from a mobile phone or landline:Dial (669) 9009128. When prompted, enter the meeting ID. The Meeting ID is listed atthe top of this agenda.To speak during the meeting: When you wish to comment on an item that is being isdiscussed, press *9 on your phone to virtually raise your hand. You will have 3 minutes.Submit a written commentYou are invited to submit a written comment in one of the following ways:Email PBAecomments@santaana.org and reference the topic in the subject line.Mail to Nuvia Ocampo, Recording Secretary, City of Santa Ana, 20 Civic Center Plaza– M20, Santa Ana, CA 92701. Deadline to submit written comments is 4:00 p.m. on the day of the meeting.Comments received after the deadline may not be distributed to the Commission but will be made part of the record. 5 Planning Commission 3/11/2024 Planning and Building Agency City of Santa Ana 20 Civic Center Plaza, Santa Ana, CA 92701 Planning Commission Staff Report March 25, 2024 Topic: Site Plan Review No. 2024-01 and Tentative Tract Map No. 2024-01 – First Harbor Mixed-Use Development (101 N. Harbor Blvd.) RECOMMENDED ACTION 1. Adopt a resolution approving Site Plan Review No. 2024-01 as conditioned; and 2. Adopt a resolution approving Tentative Tract Map No. 2024-01 as conditioned. EXECUTIVE SUMMARY Charles ‘Chuck’ Minyard with Primior, Inc. and representing Harbor and First, LLC (applicant and property owner) is requesting approval of Site Plan Review (SPR) No. 2024-01 and Tentative Tract Map (TTM) No. 2024-01 to facilitate the construction of a mixed-use development known as First Harbor Mixed-Use Development at a vacant site generally addressed as 101 North Harbor Boulevard. Pursuant to Table 3-2 (Permitted Uses) and Figure 7-1 (Permitting Process) of the Harbor Mixed-Use Transit Corridor Specific Plan (SP- 2), structures over three stories in height require approval of a SPR application by the Planning Commission. In addition, pursuant to Section 34-127 of the Santa Ana Municipal Code (SAMC), projects proposing to create four or more lots require approval of a TTM application by the Planning Commission. Staff is recommending approval of the applicant’s request due to the project’s compliance with the intent of SP-2 by providing a highly quality, mid-rise, mixed-use development at an existing vacant lot. Moreover, the project meets the intent of the General Plan by promoting a pedestrian-oriented environment and will contribute to the City’s housing stock through the production of both market-rate and affordable ownership housing units with diverse housing product types. Table 1: Project Location Information and Applicable Code Sections Item Information Project Address(es) and Council Ward 101, 111, 115, and 121 N. Harbor Blvd., 3709 and 3729 W. 1st Street, and 114 N. Figueroa Street (collectively 101 N. Harbor Blvd.) – Ward 5 Nearest Intersection First Street and Harbor Boulevard General Plan Designation District Center – High (DC-3) Zoning Designation Transit Node South of SP-2 North Commercial East Commercial and Two-Family Residences South Commercial Surrounding Land Uses West Commercial Site Size 1.56 acres SPR No. 2024-01 and TTM No. 2024-01 – First Harbor Mixed-Use Development (101 N. Harbor Blvd.) March 25, 2024 Page 2 4 1 1 8 Item Information Existing Site Development Vacant Applicable Zoning Code Sections Chapters 41 and 34 of the SAMC and SP-2 Entitlements SPR and TTM DISCUSSION Project Description The applicant is proposing to develop the existing vacant lot with a nine-story mixed-use building consisting of 15,182 square feet of leasable commercial space, 1,845 square feet of leasing office space, 181 for-sale residential condominium units (10 of which will be affordable units), 339 parking spaces, and 40,853 square feet of open space and amenities. Table 2: Project Summary Item Provided Lot Size 1.56 acres (68,062 sq. ft.) Building Square Footage (excluding parking) 295,350 sq. ft. Building Height/Stories Nine stories (98’-8” in height) Dwelling Units Per Acre (DU/AC)116 DU/AC Floor Area Ratio (FAR) 4.34 FAR Number of Units 181 for-sale residential condominium units Studios 21 units (12%) 1-bedroom 85 units (47%) 2-bedrooms 55 units (30%) Number of Bedrooms Per Unit 3-bedrooms 20 units (11%) Studios 517 sq. ft. 1-bedroom 823 sq. ft. 2-bedrooms 1,314 sq. ft. Average Unit Size 3-bedrooms 1,508 sq. ft. Retail Space 15,182 sq. ft.Commercial Square Footage Leasing Office 1,845 sq. ft. Parking 339 spaces (310 spaces required) Private Space 18,040 sq. ft. (9,050 sq. ft. required) Open Space Common Space 13,529 sq. ft. (10,209 sq. ft. required) Amenities 9,284 sq. ft. Site Planning, Architecture, & Circulation City staff, the developer, and the architects worked closely to ensure the latest principles in site planning and circulation were incorporated into the project. The project site and building massing have been designed to include stepbacks and townhome-like residential units along the east property line to ensure compatible character, preservation and privacy of the adjacent lower-intensity residential neighborhood and a transition to a more intense urban environment as envision by SP-2. The building has been designed as a lined block, consistent with SP-2, with contemporary architecture features which include SPR No. 2024-01 and TTM No. 2024-01 – First Harbor Mixed-Use Development (101 N. Harbor Blvd.) March 25, 2024 Page 3 4 1 1 8 grey and white stucco, faux-wood accent cladding, stone, brick, and aluminum storefronts. The high-quality building materials will ensure long-term durability and maintaining high value of the project. Onsite and offsite furniture and details, such as lighting, waste receptacles, benches, tables and open space areas, have also been designed to complement the project’s contemporary architecture. In addition, the high ground-floor window and ceiling heights will contribute to the high-quality commercial component of the project. The project’s design and finishes are consistent with the development standards and design guidelines found in SP-2. Vehicular access to the development will be provided by a private drive aisle accessible from Harbor Boulevard and Figueroa Street and a driveway entrance from Figueroa Street. The private drive aisle will also function as the service lane for trash services and emergency vehicles. As required by the Public Works Agency, a traffic impact analysis (Exhibit 9) was prepared for this project by Linscott, Law and Greenspan, Engineers (LLG) to analyze any project impacts to intersections and the project site access impacts to current traffic patterns. Based on the analysis, no additional improvements are required to intersections that are already being enhanced by the project along First Street, Harbor Boulevard, and Figueroa Street. The project site has addressed all the requirements of the Public Works Agency with regards to vehicular access, onsite circulation, and trash services. Commercial Components The development contains 15,182 square feet of leasable commercial space and 1,845 square feet of leasing office space on the ground floor. The commercial space is located along the frontages of Harbor Boulevard and First Street, with a small portion wrapping around Figueroa Street. The commercial areas have been designed to accommodate a range of uses common within mixed-use structures, such as cafes with outdoor dining, small size retail, and neighborhood service uses. On-site Parking On-site parking is provided via two subterranean levels of parking, ground level parking, and one podium level of parking on the second floor with a total of 333 standard vehicular parking stalls and six motorcycle parking stalls, at a rate of 1.87 parking spaces per unit. The project is providing 23 additional parking spaces than was is required by SP-2. Of the proposed 339 parking spaces, 38 parking spaces will be allocated for guest and patrons of the commercial area, with the remaining 301 spaces allocated for residence parking only. In addition, one stall will be dedicated as a drop-off/pick-up stall and two oversized loading parking stalls are provided to accommodate deliveries to the commercial tenants and move-in spaces. The commercial and resident guest parking spaces will be located on the ground floor, which will remain ungated during business hours. Residential parking will be provided via the two levels of subterranean parking and the podium parking level located on the second floor of the building. Residents will be SPR No. 2024-01 and TTM No. 2024-01 – First Harbor Mixed-Use Development (101 N. Harbor Blvd.) March 25, 2024 Page 4 4 1 1 8 provided with a transponder or similar device (e.g., fob or key card, etc.) for remote access to the residential parking area. A Parking Management Plan (PMP), attached hereto as Exhibit 9, was prepared for the project to ensure adequate parking is being provided and managed properly for all project residents, tenants, employees and guests. The PMP identifies how parking stalls will be assigned, how gates will be managed, and how access (keycard, access codes) for residents, guests, employees, and public will be provided. Based on the provided PMP, sufficient parking will be provided to satisfy the parking demand for residents, guests, patrons, and employees of the project. Nevertheless, a condition of approval requiring the property owner and/or property management company to implement and enforce the appropriate parking management strategy recommended in the PMP has been included on the project resolutions. In addition, a condition of approval has been added to require the applicant to facilitate the establishment of a parking permit district for the adjacent neighborhood in the event that street parking issues arise after project occupancy, including communicating with the residents and submitting the required documents and analysis to the Public Works Agency. Open Space and Amenities Open space and amenities will be provided on the site in a variety of means, including private unit balconies and patios, wellness center, game rooms, office/study areas, libraries, theaters, racquetball court, amenity rooftop deck, and a central courtyard. The project will contain approximately 18,040 sq. ft. of private open space in the form of private patios and balconies ranging in size from 51 to 126 square feet per unit. In addition, 13,529 sq. ft. square feet of common open space will be provided via a central courtyard located on the third floor and a rooftop deck. The central court yard will also be accessible to the general public and the patrons of the commercial area during business hours and will include outdoor tables and chairs, patio covers, and an open turf area. The rooftop deck will include a pool and spa with pool furniture such as lounge chairs, tables and umbrellas and a coffee/bar lounge area. The open space will also feature a landscape palette with seating options and a variety of hardscaping materials, trees, and shrubs. Additional project amenities to the residents will include a racquetball court within the subterranean parking area, a wellness center and locker rooms in the third floor, game rooms in the fourth floor, office/study rooms in the fifth floor, theater/gaming rooms in the sixth and seventh floors, and libraries in the eighth floor. The project is proving more open space than was is required by SP-2. Affordable Housing Opportunity and Creation Ordinance Compliance The City’s inclusionary housing ordinance, known as the Affordable Housing Opportunity and Creation Ordinance (AHOCO) (SAMC Sec. 41-1900 et seq.) applies to housing projects proposing five or more units that are also requesting an increase in allowable density or are located in certain sections of the City that were “up-zoned” to allow additional residential development after November 28, 2011, including the SP-2 area. As SPR No. 2024-01 and TTM No. 2024-01 – First Harbor Mixed-Use Development (101 N. Harbor Blvd.) March 25, 2024 Page 5 4 1 1 8 the proposed project is located within SP-2 and is seeking to develop a project per its standards, the project is subject to the AHOCO requirements of the production of affordable housing or payment of in-lieu fees. Pursuant to Section 41-1904 of the SAMC, the applicant has three options to the satisfy the AHOCO requirements; (1) construction of ten on-site affordable units; (2) construction or rehabilitation of ten off-site affordable units; or (3) payment of in-lieu fees of $15.00 per square foot of habitable area. The applicant has selected the option to construct ten on-site moderate income housing units. These units will be dispersed evenly throughout the project floors and will include one studio unit, four one bedroom units, three two bedroom units, and two three bedroom units. Project Background SP-2 was adopted in 2014 to facilitate development opportunities along Harbor Boulevard between Westminster Avenue and the border of the City of Fountain Valley and created the land use and development framework to support up to 4,600 residential units and 2 million square feet of commercial and employment space. The ultimate vision is to create a place that contains a wide mixture of retail stores, restaurants, office buildings, hotels, museums, and housing options in a more walkable, safe, and attractive environment close to transit feeding into the OC Streetcar. In 2018, the applicant submitted a commercial development that consisted of two commercial buildings totaling 36,606 square feet, surface parking, a plaza, and landscape/open space areas. This project was approved by the City’s Development Review Committee and began the plan check process but the application was withdrawn by the applicant because it was determined to be infeasible to due to insufficient parking to attract major recognized tenants. The project’s parking ratio was 1 space per 400 square feet, required by SP-2 for commercial projects. Because of this, the applicant elected to comprehensively reevaluate options for the site and is now pursing the proposed mixed-use project, which exceeds the minimum parking requirements prescribed by SP-2 by 23 spaces. Senate Bill (SB) 330 Application SB 330 became effective on January 1, 2020, and established a statewide “housing emergency” until January 1, 2025, which was extended until 2030 through the passage of SB 8. The senate bill amended Government Code Section 65941.1 with the broad goals of facilitating increased production of new residential units, protecting existing units, and providing for an expedited review and approval process for housing development projects through submittal of a “preliminary application.” It is important to note that since the application was submitted under SB 330, the project is required to comply with the objective zoning code standards applicable to the property and a decision on the project must be made in no more than five public hearings. SPR No. 2024-01 and TTM No. 2024-01 – First Harbor Mixed-Use Development (101 N. Harbor Blvd.) March 25, 2024 Page 6 4 1 1 8 On August 26, 2023, the applicant submitted a SB 330 Preliminary Application for the proposed project and the application was deemed complete by staff. On June 21, 2023, staff provided the applicant with an inconsistency letter of the project with the City’s applicable plans, programs, policies, ordinances, and standards, as required by Government Code Section 65589.5(j)(2)(A)(ii). The letter contained inconsistencies with site planning and design requirements per SP-2, the California Building Code, Orange County Fire Authority guidelines and California Fire Code, and the Public Works Agency requirements. Since then, the applicant worked with staff to ensure the project complied with the City’s applicable plans, programs, policies, ordinances, and standards, SP-2 Site Plan Review Pursuant to Table 3-2 (Permitted Uses) and Figure 7-1 (Permitting Process) of SP-2, structures over three stories in height require approval of a SPR application by the Planning Commission. Below is an analysis of findings for granting a SPR for the subject project. Table 3: Findings for Granting A SPR Approval Finding Project Compliance That the proposed development plan is consistent with the vision and objectives outlined in SP-2. The project site is located within the TNS district of SP-2 which is intended to provide for high intensity, transit-supportive mixed- use developments of up to 10 stories in height with a focus on creating pedestrian activity at the street level. The district offers opportunities to respond to the regional and local transit investments, with direct access to three existing Bus Rapid Transit (BRT) stations and proximity to the Orange County Streetcar at the corner of Harbor Boulevard and Westminster Avenue, which is approximately one mile from the project Site. The proposed project will create a new mixed-use development within close proximity to transit and will provide additional opportunities to live, work, and/or play in Santa Ana. The proposed project will provide 181 for-sale residential condominium units, of which 10 will be affordable. In addition, the project will provide approximately 15,182 square feet of leasable commercial space that will generate sale tax for the City. The proposed building height is less than ten stories as allowed in the TNS district and has been designed to include stepbacks along the east property line to ensure computability with the adjacent neighborhood. Furthermore, the commercial spaces have been designed with retail floor heights of approximately 17 feet with storefronts that will be visible from First Street and Harbor Boulevard. The project will also be built to California Building Code standards, which include energy and water conservation measures and will improve pedestrian mobility by providing enhancements to the existing sidewalks along First Street, Harbor Boulevard, and Figueroa Street. SPR No. 2024-01 and TTM No. 2024-01 – First Harbor Mixed-Use Development (101 N. Harbor Blvd.) March 25, 2024 Page 7 4 1 1 8 Finding Project Compliance That the proposed development plan is consistent with the development standards outlined in SP-2. The project is consistent with the development standards specified in Chapter 3 (Land Use Plan and Development Standards) of SP-2. The TNS allows lined block buildings with a maximum height of 10 stories. The proposed project complies with the lined block building development standards and is nine stories in height. The project also complies with the required “Shop Front” building frontage types and floor heights which requires a minimum ground floor height of 15 feet and 9 feet for upper floors. The project is proposing a ground floor height of 17 feet with upper floors averaging 9 feet in height. As required per SP-2, the project requires a total of 310 parking spaces and the project contains 339 parking spaces. SP-2 requires that common open space be provided at 15-percent of the lot size and 50 square feet per unit for private open space. The project is proposing more common and private space than what is required by SP-2 and additional amenities than required. Lastly, the access and egress for the project has been thoroughly review by the Public works Agency through a traffic analysis for compliance with all applicable development standards. That the proposed development plan is designed to be consistent with the design guidelines outlined in SP-2. The project is consistent with the design standards specified in Chapter 6 (Design Guidelines) of SP-2. The building is designed with a high quality design that includes varied massing, changes in form, and is comprised of high quality materials including grey and white stucco, faux-wood accent cladding, stone, brick, and aluminum storefronts, and high quality architectural detailing (e.g., exterior lighting, entry doors, fenestration, etc.). During the development project review process, staff provided extensive design comments, which resulted in higher-quality building materials and building elevations that are architecturally detailed and designed to be pedestrian-oriented. Lastly, the project has been designed to ensure compatibility between the adjacent neighborhood and internal mixed uses. The commercial uses have separate entrances from the residential uses and the parking management plan will manage parking between the residential and nonresidential uses. General Plan Consistency The project supports several goals and policies of the General Plan. Specifically, the project is consistent with Economic Prosperity Element (EP) Policy EP-3.4 which encourages the development of “complete communities” that provide a range of housing, services, amenities, and transportation options that support the retention and attraction of skilled workforce and employment. Goal 1 of the Land Use Element (LU) encourages projects that improve quality of life and respects the existing community. Policy LU-1.2 supports innovative development policies to expand homeownership opportunities at all income levels. Policy LU-1.6 encourages residential mixed-use development, within the City’s District Centers, Urban Neighborhoods, and adjacent to high quality transit. Policy SPR No. 2024-01 and TTM No. 2024-01 – First Harbor Mixed-Use Development (101 N. Harbor Blvd.) March 25, 2024 Page 8 4 1 1 8 LU-2.2 encourages the development of a range of commercial uses to capture a greater share of local spending and that offer a range of employment opportunities. Policy LU- 2.5 encourages infill mixed-use development at all ranges of affordability to reduce vehicle miles traveled, improve jobs/housing balance, and promote social interaction. Policy LU-4.7 encourages the development of mixed-income developments with mixed housing types to create inclusive communities and economically diverse neighborhoods. Policy UD-1.1 of the Urban Design Element (UD) requires that all developments feature high quality design, materials, finishes, and construction. Policy UD-2.2 encourages buffers and other urban design strategies to encourage computability of new development with the scale, bulk, and pattern of existing development. Lastly Policy HE-2.5 of the Housing Element (HE) encourages the creation of higher intensity, mixed-use urban villages and pedestrian-oriented experiences that access and support the office centers, commercial services, and cultural activities within District Centers and Urban Neighborhood designated areas. Policy HE-2.5 supports diverse types, prices, and sizes of housing and Policy HE-2.6 supports excellence in architecture design through the use of materials and colors, building treatments, landscaping, open space, parking, and environmentally sensitive building and design practices. Tentative Tract Map Subdivision requests are governed by Chapter 34 of the SAMC. Pursuant to Section 66473.5 and 66474 of the California Subdivision Map Act, applications for tentative tract maps are approved when it can be shown that findings can be made in support of the request. Specifically, findings related to the proposal need to be made that find the project is consistent with the General Plan, the site is physically suitable for the type and density of the proposed project, the proposed project will not cause substantial environmental damage or substantially and avoidably injure fish and wildlife or their habitat, the proposed project will not cause serious public health problems, or the proposed project will not conflict with easements necessary for public access through or use of the property must be made. Using this information, staff has prepared the following analysis, which, in turn forms the basis for the recommendation contained in this report. In analyzing the applicant’s request, staff believes that the following analysis warrants approval of the tentative tract map. The applicant is seeking approval of a tentative tract map (County Map No. 19274) to create one legal lot and 181 residential condominium lot units. In reviewing the project, staff determined that the proposal as conditioned is consistent with the various provisions of the City’s General Plan and SP-2. Further, conditions of approval have been included to ensure the site’s landscaping, architectural design, and Covenants, Conditions and Restrictions (CC&Rs) continue to be in compliance with all applicable standards of the SAMC and SP-2 in the future. No adverse environmental impacts to fish or wildlife populations were identified as the project site is located in a built-out, urbanized area SPR No. 2024-01 and TTM No. 2024-01 – First Harbor Mixed-Use Development (101 N. Harbor Blvd.) March 25, 2024 Page 9 4 1 1 8 surrounded by existing development. Finally, the tentative tract map was found to be consistent with the California Subdivision Map Act and Chapter 34 of the SAMC. Public Notification and Community Outreach Project notifications were posted, published, and mailed in accordance with City and State regulations. Copies of the public notice, including a 1,000-foot notification radius map, and the site posting are provided in Exhibit 11. In addition, staff contacted the provided contacts for the Riverview West and Santa Anita neighborhood associations to ensure they were aware of the project and public hearing. At the time this report was printed, no issues of concern were raised regarding the proposed development. The applicant held two community meetings in conformance to the Sunshine Ordinance notification requirements. The first meeting was on held Wednesday, March 29, 2023 and the second meeting was held on Wednesday, September 20, 2023. Both meetings were publicly noticed in the OC Register, posted on the City’s website, and invitation mailers were sent to all addresses within a 1,000-foot radius of the project site, as well as local community organizations. Participants asked questions about the project timing and construction impacts, affordability levels, project density, and about potential traffic and parking impacts to the community. Approximately 15 individuals attended both meetings. Materials from both meetings are posted to the project’s City webpage for public viewing. FISCAL IMPACT AND ECONOMIC ANALYSIS The applicant prepared a fiscal and economic impact analysis of the proposed project which included confirmation of fiscal and economic benefits to the City from the proposed development. The analysis reveals positive economic and fiscal impacts from the proposed development due to the project site’s location in a high-value, jobs-rich area surrounded by employment centers and mixed-use commercial developments. The report’s conclusions about the proposed project are noted in Table 4 below. Table 4: Key Findings of the Proposed Project Topic Proposed Project Property Tax Revenue The project is projected to generate a property tax revenue to the City of $162,433 annually. In addition, the project will generate $123,207 annually in Property Tax in Lieu of Vehicle License Fee revenue. Sale tax Revenue The project is projected to generate $55,313 in sale tax revenue by the residential population, $2,922 by the employee population, and $48,962 by the commercial development annually. Other Revenues The City will collect permit fees during the plan check process for the project and other fines, franchise fees, licenses and permits fees that are estimated at $29,133. Employment Impacts After completion, the project will maintain approximately 50 jobs. SPR No. 2024-01 and TTM No. 2024-01 – First Harbor Mixed-Use Development (101 N. Harbor Blvd.) March 25, 2024 Page 10 4 1 1 8 Topic Proposed Project Fiscal Impact Based on the estimated revenue and the estimated total expenditures, there is a net positive fiscal impact to the City’s General Fund as a result of the project of approximately $48,639 annually. ENVIRONMENTAL IMPACT In accordance with the California Environmental Quality Act (CEQA) and the CEQA Guidelines, the project is within the scope of the 2014 Harbor Boulevard Mixed-Use Transit Corridor Plan Environmental Impact Report (EIR) (SCH No. 2013061027). The 2014 EIR anticipated potential development of up to 4,623 dwelling units and 1,954,261 square feet of commercial area. The 2014 EIR analyzed impacts related to aesthetics, agriculture/forestry, air quality, biology, cultural resources, geology/soils, greenhouse gas emissions, hazards and hazardous materials, hydrology and water quality, land use and planning, mineral resources, noise, population/housing, public services, transportation/traffic, tribal cultural resources and utilities. The EIR concluded that there would be significant and unavoidable impacts associated with air quality and mitigation measures were developed and recorded through an approved Mitigation Monitoring and Reporting Program (MMRP). The previously prepared 2014 EIR adequately described the project’s environmental setting, significant impacts and alternatives, and mitigation measures related to each impact. There are no substantial changes with respect to circumstances under which the project is undertaken that will require major revisions to the EIR. There is no new information of substantial importance, and there are no new environmental impact or mitigation measure needed. All applicable mitigation measure, attached hereto as Exhibit 10, applied to the previously prepared 2014 EIR and will be applied to this project. As such, a Notice of Determination, Environmental Review No. 2023-71, will be filed for this project. EXHIBIT(S) 1. Resolution Approving SPR No. 2024-01 as conditioned 2. Resolution Approving TTM No. 2024-01 as conditioned 3. Vicinity Zoning and Aerial View 4. Site Photo 5. Overall Site Plan/ Conceptual Landscape Plan 6. Floor Plans 7. Project Renderings 8. Tentative Tract Map (County Map No. 19274) 9. Traffic Analysis & Parking Management Plan 10. SP-2 Mitigation Monitoring and Reporting Program 11. Copy of Public Notice SPR No. 2024-01 and TTM No. 2024-01 – First Harbor Mixed-Use Development (101 N. Harbor Blvd.) March 25, 2024 Page 11 4 1 1 8 Submitted By: Jerry C. Guevara, AICP, Senior Planner Approved By: Minh Thai, Executive Director of Planning and Building Agency Resolution No. 2024-XX Page 1 of 12 RESOLUTION NO. 2024-XX A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF SANTA ANA APPROVING SITE PLAN REVIEW NO. 2024-01 AS CONDITIONED FOR A MIXED- USE DEVELOPMENT AT 101, 111, 115, AND 121 NORTH HARBOR BOULEVARD, 3709 AND 3729 WEST FIRST STREET, AND 114 NORTH FIGUEROA STREET (APNS: 198-182-37 AND 198-182-38) BE IT RESOLVED BY THE PLANNING COMMISSION OF THE CITY OF SANTA ANA AS FOLLOWS: Section 1. The Planning Commission of the City of Santa Ana hereby finds, determines and declares as follows: A.Charles ‘Chuck’ Minyard with Primior, Inc. and representing Harbor and First, LLC (“Applicant” and “Property Owner”) is requesting approval of Site Plan Review (“SPR”) No. 2024-01 and Tentative Tract Map (“TTM”) No. 2024-01 to facilitate the construction of a mixed-use development (“Project”) known as First Harbor Mixed-Use Development located at 101 North Harbor Boulevard “Project Site”). B.The Project entails, among other improvements; (1) development of the Project Site with a mixed-use building with two subterranean parking levels and nine stories above grade containingn15,182 square feet of leasable commercial space, 1,845 square feet of leasing office space, 181 for-sale residential condominium units, 339 parking spaces, and 40,853 square feet of open space and amenities, (2) approval of SPR No. 2024- 01; and (3) approval of Tentative Tract Map (“TTM”) No. 2024-01, to be considered by the Planning Commission on March 25, 2024 by way of a separate resolution. C.The Project Site has a General Plan land use designation of District Center – High (“DC-5”) and is located within the Transit Node South (“TNS”) district of the Harbor Mixed-Use Transit Corridor Specific Plan (“SP-2”). D.Pursuant to Chapter 3 (Land Use Plan and Development Standards), Table 3-2 and Chapter 7 (Administration and Implementation), Figure 7-1 of SP-2, approval of a SPR by the Planning Commission is required for structures over three stories in height. E.The City previously certified the Final Environmental Impact Report (“EIR”), adopted a Mitigation Monitoring and Reporting Program, adopted a Statement of Overriding Considerations, and approved the 2014 Harbor Boulevard Mixed-Use Transit Corridor Plan Environmental Impact Report (EIR) (SCH No. 2013061027) on October 21, 2014 (Resolution No. 2014- 069)pursuant to the California Environmental Quality Act (“CEQA”). Exhibit 1 Resolution No. 2024-XX Page 2 of 12 F.Pursuant to State CEQA Guidelines section 15162, a lead agency shall consider whether additional CEQA review is required when considering a subsequent discretionary approval for a project for which an EIR was certified. G.The Planning Commission has independently reviewed and considered the previously certified EIR and other documents in the record before it. H.On March 25, 2024, the Planning Commission of the City of Santa Ana held a duly-noticed public hearing on SPR No. 2024-01. I.The Project supports several goals and policies of the General Plan. Specifically, the Project is consistent with Economic Prosperity Element (EP) Policy EP-3.4 which encourages the development of “complete communities” that provide a range of housing, services, amenities, and transportation options that support the retention and attraction of skilled workforce and employment. Goal 1 of the Land Use Element (LU) encourages projects that improve quality of life and respects the existing community. Policy LU-1.2 supports innovative development policies to expand homeownership opportunities at all income levels. Policy LU-1.6 encourages residential mixed-use development, within the City’s District Centers, Urban Neighborhoods, and adjacent to high quality transit. Policy LU-2.2 encourages the development of a range of commercial uses to capture a greater share of local spending and that offer a range of employment opportunities. Policy LU-2.5 encourages infill mixed-use development at all ranges of affordability to reduce vehicle miles traveled, improve jobs/housing balance, and promote social interaction. Policy LU- 4.7 encourages the development of mixed-income developments with mixed housing types to create inclusive communities and economically diverse neighborhoods. Policy UD-1.1 of the Urban Design Element (UD) requires that all developments feature high quality design, materials, finishes, and construction. Policy UD-2.2 encourages buffers and other urban design strategies to encourage computability of new development with the scale, bulk, and pattern of existing development. Lastly Policy HE- 2.5 of the Housing Element (HE) encourages the creation of higher intensity, mixed-use urban villages and pedestrian-oriented experiences that access and support the office centers, commercial services, and cultural activities within District Centers and Urban Neighborhood designated areas. Policy HE-2.5 supports diverse types, prices, and sizes of housing and Policy HE-2.6 supports excellence in architecture design through the use of materials and colors, building treatments, landscaping, open space, parking, and environmentally sensitive building and design practices. J.The Planning Commission of the City of Santa Ana determines that the following findings, which must be established in order to grant a SPR approval pursuant to SP-2, have been established for SPR No. 2024-01 to allow the construction the Project. Exhibit 1 Resolution No. 2024-XX Page 3 of 12 1.That the proposed development plan is consistent with the vision and objectives outlined in SP-2. The Project Site is located within the TNS district of SP-2 which is intended to provide for high intensity, transit- supportive mixed-use developments of up to 10 stories in height with a focus on creating pedestrian activity at the street level. The district offers opportunities to respond to the regional and local transit investments, with direct access to three existing Bus Rapid Transit (BRT) stations and proximity to the Orange County Streetcar at the corner of Harbor Boulevard and Westminster Avenue, which is approximately one mile from the Project Site. The Project will create a new mixed-use development within close proximity to transit and will provide additional opportunities to live, work, and/or play in Santa Ana. The Project will provide 181 for-sale residential condominium units, of which 10 will be affordable. In addition, the Project will provide approximately 15,182 square feet of leasable commercial space that will generate sale tax for the City. The building height is less than ten stories as allowed in the TNS district and has been designed to include stepbacks along the east property line to ensure computability with the adjacent neighborhood. Furthermore, the commercial spaces have been designed with retail floor heights of approximately 17 feet with storefronts that will be visible from First Street and Harbor Boulevard. The Project will also be built to California Building Code standards, which include energy and water conservation measures and will improve pedestrian mobility by providing enhancements to the existing sidewalks along First Street, Harbor Boulevard, and Figueroa Avenue. 2.That the proposed development plan is consistent with the development standards outlined in SP-2. The Project is consistent with the development standards specified in Chapter 3 (Land Use Plan and Development Standards) of SP-2. The TNS allows lined block buildings with a maximum height of 10 stories. The Project complies with the lined block building development standards and is nine stories in height. The Project also complies with the required “Shop Front” building frontage type and floor heights which require a minimum ground floor height of 15 feet and 9 feet for upper floors. The Project is proposing a ground floor height of 17 feet with upper floors averaging 9 feet in height. As required per SP-2, the Project requires a total of 310 parking spaces and the Project contains 339 Exhibit 1 Resolution No. 2024-XX Page 4 of 12 parking spaces. SP-2 requires that common open space be provided at 15-percent of the lot size and 50 square feet per unit for private open space. The Project is proposing more common and private space and amenities than what is required by SP-2. Lastly, vehicular access for the Project has been thoroughly review by the Public Works Agency through a traffic analysis for compliance with all applicable regulations. 3. That the proposed development plan is consistent with the design guidelines outlined in SP-2. The Project is consistent with the design standards specified in Chapter 6 (Design Guidelines) of SP-2. The building is designed with a high quality design that includes varied massing, changes in form, and is comprised of high quality materials including grey and white stucco, faux-wood accent cladding, stone, brick, and aluminum storefronts, and high quality architectural detailing (e.g., exterior lighting, entry doors, fenestration, etc.). During the development project review process, staff provided extensive design comments, which resulted in higher-quality building materials and building elevations that are architecturally detailed and designed to be pedestrian-oriented. Lastly, the Project has been designed to ensure compatibility between the adjacent neighborhood and internal mixed uses. The commercial uses have separate entrances from the residential uses and the parking management plan will manage parking between the residential and nonresidential uses. Section 2. The Applicant shall indemnify, protect, defend and hold the City and/or any of its officials, officers, employees, agents, departments, agencies, authorized volunteers, and instrumentalities thereof, harmless from any and all claims, demands, lawsuits, writs of mandamus, and other and proceedings (whether legal, equitable, declaratory, administrative or adjudicatory in nature), and alternative dispute resolution procedures (including, but not limited to arbitrations, mediations, and such other procedures), judgments, orders, and decisions (collectively “Actions”), brought against the City and/or any of its officials, officers, employees, agents, departments, agencies, and instrumentalities thereof, that challenge, attack, or seek to modify, set aside, void, or annul, any action of, or any permit or approval issued by the City and/or any of its officials, officers, employees, agents, departments, agencies, and instrumentalities thereof (including actions approved by the voters of the City) for or concerning the Project, whether such Actions are brought under the Ralph M. Brown Act, California Environmental Quality Act, the Planning and Zoning Law, the Subdivision Map Act, Code of Civil Procedure sections 1085 or 1094.5, or any other federal, state or local constitution, statute, law, ordinance, charter, rule, regulation, or any decision of a court of competent jurisdiction. It is expressly agreed that the City shall have the right to approve the legal counsel providing the City’s defense, and that Applicant shall reimburse the City for any costs and expenses Exhibit 1 Resolution No. 2024-XX Page 5 of 12 directly and necessarily incurred by the City in the course of the defense. City shall promptly notify the Applicant of any Action brought and City shall cooperate with Applicant in the defense of the Action. Section 3. The Planning Commission has reviewed and considered the information contained in the certified EIR and all supporting documentation, copies of which are on file at the Planning Department and are incorporated by reference as though set forth fully herein. Based on this review, the Planning Commission finds that any comments received regarding Project have been examined and determined to not modify the significant conclusions of the EIR. The Planning Commission further finds that no additional feasible mitigation measures within the City’s authority are necessary to reduce the environmental impacts of the Project, because all impacts of the Project are either less than significant, will be mitigated to a level of less than significant through compliance with the existing mitigation, or remain significant and unavoidable even with the imposition all of feasible mitigation and all applicable mitigation measures, attached hereto as Exhibit B applied to the certified EIR and will be applied to the Project. Finally, based on the substantial evidence set forth in the record, including but not limited to the certified EIR, the Planning Commission finds that none of the conditions triggering the need for subsequent environmental review have occurred. Specifically, the Planning Commission finds that no subsequent environmental review is required pursuant to State CEQA Guidelines section 15162 because: a. No substantial changes are proposed by the Project which will require major revisions of the EIR due to the involvement of new significant environmental effects or a substantial increase in the severity of previously identified significant effects; b. No substantial changes have occurred with respect to the circumstances under which the Project is being undertaken which will require major revisions of the EIR due to the involvement of new significant, environmental effects or a substantial increase in the severity of previously identified significant effects; and c. No new information of substantial importance, which was not known and could not have been known with the exercise of reasonable diligence at the time the EIR was certified, shows that: (i) either the Project will have one or more new significant effects; (ii) significant effects of modifications to the Project examined in the EIR will be substantially more severe; (iii) mitigation measures or alternatives previously found not to be feasible would in fact be feasible and would substantially reduce one or more significant effects of the Project, but the City declined to adopt the measure or alternative; or (iv) mitigation measures or alternatives which are considerably different from those analyzed in the EIR would substantially reduce one or more significant effects on the environment, but the City declines to adopt the measure or alternative. Section 4. The Planning Commission directs staff to file a Notice of Determination with the County Clerk’s Office and with the State Clearinghouse within five (5) working days of adoption of this Resolution. Section 5. This Resolution shall not be effective unless and until the Planning Commission Resolution for Tentative Tract Map No. 2024-01 is adopted and becomes effective. If said Resolution is for any reason held to be invalid or unconstitutional by the decision of any court of competent jurisdiction, or otherwise does not go into effect for Exhibit 1 Resolution No. 2024-XX Page 6 of 12 any reason, then this Resolution shall be null and void and have no further force or effect. Section 6. The Planning Commission of the City of Santa Ana, after conducting the public hearing, hereby approves SPR No. 2024-01, as conditioned in Exhibit A, attached hereto and incorporated herein for the Project at the Project Site. This decision is based upon the evidence submitted at the above said hearing, which includes, but is not limited to: The Request for Planning Commission Action dated March 25, 2024, and exhibits attached thereto; and the public testimony, written and oral, all of which are incorporated herein by this reference. ADOPTED this 25th day of March, 2024 by the following vote: AYES: Commissioners: NOES: Commissioners: ABSENT: Commissioners: ABSTENTIONS: Commissioners: _______________________ Bao Pham, Chairman APPROVED AS TO FORM: Sonia R. Carvalho, City Attorney By:________________________ Laura Rossini Chief Assistant City Attorney Exhibit 1 Resolution No. 2024-XX Page 7 of 12 CERTIFICATE OF ATTESTATION AND ORIGINALITY I, NUVIA OCAMPO, Recording Secretary, do hereby attest to and certify the attached Resolution No. 2024-XX to be the original resolution adopted by the Planning Commission of the City of Santa Ana on March 25, 2024. Date: ________________ ____________________________________ Nuvia Ocampo Recording Secretary City of Santa Ana Exhibit 1 Resolution No. 2024-XX Page 8 of 12 Exhibit A Conditions for Approval for Site Plan Review No. 2024-01 Site Plan Review No. 2024-01 is approved subject to compliance, to the reasonable satisfaction of the Planning Manager, with all applicable sections of the Santa Ana Municipal Code, the California Administrative Code, the California Building Standards Code, and all other applicable regulations. The Applicant shall comply with each and every condition listed in order to exercise the rights conferred by this site plan review. The Applicant shall remain in compliance with all conditions listed below throughout the life of the development Project. Failure to comply with each and every condition may result in the revocation of the site plan review. 1.All site improvements shall conform to the Development Project Review (DP) No. 2023-08, and the staff report exhibits incorporated herein by reference. 2.Any amendment to this site plan review, including modifications to approved materials, finishes, architecture, site plan, landscaping, unit count, mix, and square footages shall be submitted to the Planning Division for review. At that time, staff will determine if administrative relief is available or if the site plan review must be amended. 3.The Project shall comply with all recommendations contained with the technical studies and reports prepared for the Project. All studies and reports shall be finalized by the Applicant and approved by the City of Santa Ana prior to the issuance of any building permits. 4.The Project shall comply with all applicable mitigation measures as identified by the Mitigation Monitoring and Reporting Program of the 2014 Environmental Impact Report (EIR) (SCH No. 2013061027), attached hereto as Exhibit B. 5.The parking management measures as identified by the Traffic Analysis and Parking Management Plan (PMP), attached hereto as Exhibit C, shall be incorporated into the Project and shall apply through the life of the Project. The objectives of the PMP are intended to: a.Restrict residents from parking in the commercial and guest parking spaces; b.Restrict guests from parking in the reserved resident spaces and require guests to park in designated guest spaces; c.Restrict vehicles from exceeding the time restriction on the short term parking; Exhibit 1 Resolution No. 2024-XX Page 9 of 12 d.Allow for the use of “short-term/time restricted” parking spaces allocated to the retail and leasing office for use by residents and resident guests after business hours, as necessary; e.Develop the framework for parking agreements between the leasing office and the tenants; and f.Prevent residents, guests, and commercial patrons, from parking in the neighborhood. In the event that documented and sustained street parking issues arise in the adjacent single-family neighborhood after full Project occupancy, the Applicant shall facilitate the establishment of a parking permit district for the neighborhood, including preparation of a petition, gathering property owner signatures, and completing document/analysis as required by the Public Works Agency, at the Applicant’s full and sole expense. 6.Exterior building and exterior parking structure materials, finishes and colors for the Project shall comply with the approved materials board submitted for the Project and as approved by the Planning and Building Agency. Any changes to the materials, finishes and colors shall be approved by the Planning and Building Agency. All trash enclosures and similar ancillary structures shall match the texture, material and color of the primary building. 7.Prior to issuance of building permits, the Applicant shall submit a construction schedule and staging plan to the Planning Division for review and approval. The plan shall include construction hours, staging areas, parking, security, and site screening during Project construction. 8.Prior to issuance of building permits, an exterior lighting plan for the security and safety of on-site areas such as building entrances, parking, loading, pedestrian walkways, alley walkways and open space areas shall be provided to the Planning and Building Agency and Police Department for review and approval. A minimum of one foot-candle evenly distributed across a parking lot is recommended. At entrances and loading areas, up to 2 foot-candles may be appropriate. Decorative night lighting shall also be installed. Low energy lights, such as LED lights or solar powered lights, shall be used whenever possible. Light fixtures and their structural support shall be designed to be architecturally compatible with the main buildings on-site. Direct glare onto adjoining property, streets, or skyward shall be avoided. All lighting fixtures shall be shielded to confine light spread on-site. 9.Prior to the issuance of a building permit, a landscape and public realm plan in accordance with the Harbor Mixed-Use Transit Corridor Specific Plan (SP-2) and the Water Efficient Landscape Ordinance shall be submitted to the Planning Division for review and approval and shall include provisions to ensure ongoing maintenance of landscaping and replacement of any dead and missing landscaping in a timely manner. Exhibit 1 Resolution No. 2024-XX Page 10 of 12 10.Prior to issuance of a Certificate of Occupancy, a master sign program in accordance with SP-2 shall be submitted for review and approval by the Planning Division. 11.Prior to issuance of a Certificate of Occupancy issuance, a Public Art Program shall be submitted to the Planning Division for review and approval. Public Art shall be installed and maintained with a value equivalent to one-half of one percent (0.5%) of the total construction cost of the development. Total construction cost shall mean all design, engineering and construction costs. 12.Abandoned and vacant properties shall be secured so as not to be accessible to unauthorized persons. Securing of vacant or abandoned property includes but is not limited to closing and locking of windows, doors (walk-through, sliding and garage), gates and any other opening that may allow access to the interior of the property and or structure(s). In the case of broken windows securing means re- glazing or boarding the window. If deemed necessary by the Code Enforcement Manager, securing of vacant or abandoned property may require the provision of on-site security guard services. Such services shall be of sufficient duration and frequency to ensure that the property remains secure and no unauthorized persons may gain entry. If the vacant or abandoned property is owned by a corporation and/or out of area beneficiary/trustee/owner, a local property management company shall be contracted to perform weekly inspections to verify that the abandoned property is maintained in accordance with the requirements of this section, and any other applicable laws. 13.The Project shall be posted with the name and 24-hour contact phone number of the local property management company. The posting shall be no less than eighteen (18) inches × twenty-four (24) inches, shall be posted on every street frontage, shall be of a font that is legible from a distance of forty-five (45) feet, and shall contain the following verbiage: "THIS PROPERTY MANAGED BY _______," and "TO REPORT PROBLEMS OR CONCERNS CALL (name and phone number)." The posting shall be placed on the interior of a window facing the street to the front of the property so it is visible from the street, or secured to the exterior of the building/structure facing the street of the front of the property so it is visible from the street. If no such area exists, the posting shall be on a stake of sufficient size to support the posting, in a location that is visible from the street to the front of the property, and to the extent possible, not readily subject to potential vandalism. Exterior posting shall be constructed of, and printed with weather resistant materials. The local property management company shall inspect the property on a weekly basis, or more frequently, to determine if the Project is in compliance with the requirements of this agreement. If it is determined that the Project is not in compliance, it is the company's responsibility to bring the Project into compliance. 14.Prior to the issuance of a Certificate of Occupancy, a Property Maintenance Agreement shall be recorded against the property. The agreement will be subject to review and applicability by the Planning and Building Agency, the Community Development Agency, the Public Works Agency, and the City Attorney to ensure that the property and all improvements located thereupon are properly maintained. Applicant (and the owner of the property upon which the authorized Exhibit 1 Resolution No. 2024-XX Page 11 of 12 use and/or authorized improvements are located if different from the Applicant) shall execute a maintenance agreement with the City of Santa Ana which shall be recorded against the property and which shall be in a form reasonably satisfactory to the City Attorney. The maintenance agreement shall contain covenants, conditions and restrictions relating to the following: a.Compliance with operational conditions applicable during any period(s) of construction or major repair (e.g., proper screening and securing of the construction site; implementation of proper erosion control, dust control and noise mitigation measure; adherence to approved Project phasing etc.); b.Compliance with ongoing operational conditions, requirements and restrictions, as applicable (including but not limited to hours of operation, security requirements, the proper storage and disposal of trash and debris, enforcement of the parking management plan, and/or restrictions on certain uses); c.Ongoing compliance with approved design and construction parameters, signage parameters and restrictions as well as landscape designs, as applicable; d.Ongoing maintenance, repair and upkeep of the property and all improvements located thereupon (including but not limited to controls on the proliferation of trash and debris on or about the property; the proper and timely removal of graffiti; the timely maintenance, repair and upkeep of damaged, vandalized and/or weathered buildings, structures and/or improvements; the timely maintenance, repair and upkeep of exterior paint, parking striping, lighting and irrigation fixtures, walls and fencing, publicly accessible bathrooms and bathroom fixtures, landscaping and related landscape improvements and the like, as applicable); e.If Applicant and the owner of the property are different (e.g., if the Applicant is a tenant or licensee of the property or any portion thereof), both the Applicant and the owner of the property shall be signatories to the maintenance agreement and both shall be jointly and severally liable for compliance with its terms; f.The maintenance agreement shall further provide that any party responsible for complying with its terms shall not assign its ownership interest in the property or any interest in any lease, sublease, license or sublicense, unless the prospective assignee agrees in writing to assume all of the duties, obligations and responsibilities set forth under the maintenance agreement; and g.The maintenance agreement shall contain provisions relating to the enforcement of its conditions by the City and shall also contain provisions authorizing the City to recover costs and expenses which the City may incur arising out of any enforcement and/or remediation efforts which the Exhibit 1 Resolution No. 2024-XX Page 12 of 12 City may undertake in order to cure any deficiency in maintenance, repair or upkeep or to enforce any restrictions or conditions upon the use of the property. The maintenance agreement shall further provide that any unreimbursed costs and/or expenses incurred by the City to cure a deficiency in maintenance or to enforce use restrictions shall become a lien upon the property in an amount equivalent to the actual costs and/or expense incurred by the City. Exhibit 1 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 9 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) 5.2 AIR QUALITY 2-1 Applicants for new development projects within the Harbor Boulevard Mixed Use Transit Corridor Plan shall require the construction contractor to use equipment that meets the United States Environmental Protection Agency (EPA)-Certified emissions standards according to the following schedule. •From the end of 2011 to December 31, 2014, all project-relatedoff-road diesel-powered construction equipment greater than 50horsepower shall meet Tier 3 off-road emissions standards. Anyemissions control device used by the contractor shall achieveemissions reductions that are no less than what could beachieved by a Level 3 diesel emissions control strategy for asimilarly sized engine, as defined by CARB regulations. •After January 1, 2015, all off-road diesel-powered constructionequipment greater than 50 horsepower shall meet the Tier 4Final emission standards. Any emissions control device used bythe contractor shall achieve emissions reductions that are noless than what could be achieved by a Level 4 diesel emissionscontrol strategy for a similarly sized engine, as defined by CARBregulations. Prior to construction, the project engineer shall ensure that all demolition and grading plans clearly show the requirement for EPA Tier 3 or higher emissions standards for construction equipment over 50 horsepower. During construction, the construction contractor shall maintain a list of all operating equipment in use on the project site for verification by the Building Safety Division. The construction equipment list shall state the makes, models, and numbers of construction equipment onsite. Equipment shall properly service and maintain construction equipment in accordance with the manufacturer’s recommendations. Construction contractors shall also ensure that all nonessential idling of construction equipment is restricted to five minutes or less in compliance with California Air Project applicant Prior to grading permits; on-going monitoring during construction Planning and Building Agency, Building Safety Division Exhibit B to Exhibit 1 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements Page 10 PlaceWorks Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) Resources Board’s Rule 2449. 2-2 Applicants for new development projects within the Harbor Boulevard Mixed Use Transit Corridor Plan shall require the construction contractor to prepare a dust control plan and implement the following measures during ground-disturbing activities in addition to the existing requirements for fugitive dust control under South Coast Air Quality Management District Rule 403 to further reduce PM10 and PM2.5 emissions. The Building Safety Division shall verify compliance that these measures have been implemented during normal construction site inspections. •Following all grading activities, the construction contractor shallreestablish ground cover on the construction site throughseeding and watering. •During all construction activities, the construction contractor shallsweep streets with Rule 1186–compliant, PM10-efficient vacuumunits on a daily basis if silt is carried over to adjacent publicthoroughfares or occurs as a result of hauling. •During all construction activities, the construction contractor shallmaintain a minimum 24-inch freeboard on trucks hauling dirt,sand, soil, or other loose materials and tarp materials with afabric cover or other cover that achieves the same amount ofprotection. •During all construction activities, the construction contractor shallwater exposed ground surfaces and disturbed areas a minimumof every three hours on the construction site and a minimum ofthree times per day. •During all construction activities, the construction contractor shalllimit onsite vehicle speeds on unpaved roads to no more than 15miles per hour. Project applicant Prior to grading permits; on-going monitoring during construction Planning and Building Agency, Building Safety Division 2-3 Applicants for new development projects within the Harbor Boulevard Mixed Use Transit Corridor Plan shall require the construction contractor to use coatings and solvents with a volatile organic Project applicant Prior to building permits; on-going monitoring during construction Planning and Building Agency, Building Safety Division Exhibit B to Exhibit 1 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 11 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) compound (VOC) content lower than required under Rule 1113 (i.e., super compliant paints). All architectural coatings shall be applied either by (1) using a high-volume, low-pressure spray method operated at an air pressure between 0.1 and 10 pounds per square inch gauge to achieve a 65 percent application efficiency; or (2) manual application using a paintbrush, hand-roller, trowel, spatula, dauber, rag, or sponge, to achieve a 100 percent applicant efficiency. The construction contractor shall also use precoated/natural colored building materials, where feasible. Use of low-VOC paints and spray method shall be included as a note on architectural building plans and verified by the Building Safety Division during construction. 2-4 Applicants of residential developments which are designed to include shared community barbeques shall only install electric powered barbeque units. These units shall be specified on site and building plans and shall be verified by the Building Safety Division prior to issuance of a Certificate of Occupancy. Project applicant Prior to issuance of certificate of occupancy Planning and Building Agency, Building Safety Division 2-5 Applicant-provided appliances shall be Energy Star appliances (dishwashers, refrigerators, clothes washers, and dryers). Installation of Energy Star appliances shall be verified by the Building Safety Division during plan check. Project applicant Prior to issuance of certificate of occupancy Planning and Building Agency, Building Safety Division 2-6 Applicants of residential developments which include garage and/or car port parking shall ensure that garage and/or car port parking are electrically wired to accommodate a Level 2 (240 volt) electric vehicle charging outlet per dwelling unit. The location of the electrical outlets shall be specified on building plans and proper installation shall be verified by the Building Safety Division prior to issuance of a Certificate of Occupancy. Project applicant Prior to issuance of certificate of occupancy Planning and Building Agency, Building Safety Division 2-7 Applicants of retail, commercial, office, and other non-residential development shall provide Level 2 vehicle charging stations for public use and where feasible, coordinate with the City of Santa Ana to install Level 3 (480 volt or higher) charging stations. The location of the charging station(s) shall be specified on site and building plans Project applicant Prior to issuance of certificate of occupancy Planning and Building Agency, Building Safety Division Exhibit B to Exhibit 1 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements Page 12 PlaceWorks Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) and proper installation shall be verified by the Building Safety Division prior to issuance of a Certificate of Occupancy. 2-8 Applicants for non-residential projects within the Harbor Boulevard Mixed Use Transit Corridor Plan, that employ 20 or more people—which is equivalent to 16,000 square feet of retail space or 10,000 square feet of office space—shall implement an employee commute trip reduction (CTR) program. The CTR program shall identify alternative modes of transportation to the project, including transit schedules, bike and pedestrian routes, and carpool/vanpool availability. Information regarding these programs shall be readily available to employees and clients. The project applicant or designee shall consider the following incentives for commuters as part of the CTR program: • Rideshare matching assistance through OCTA • Subsidized public transit passes • Vanpool assistance • Car or bike-sharing program • Bicycle end-trip support facilities such as bike storage or lockers. Project applicant Prior to issuance of certificate of occupancy Planning and Building Agency, Planning Division 2-9 Applicants of commercial, office, retail, and other non-residential development within the specific plan area shall provide the following features to reduce project-related mobile-source air pollutant emissions: • Preferential parking for carpools and vanpools. • Preferential parking for alternative-fuel vehicles (e.g., compressed natural gas or hydrogen). • Secure bicycle parking and storage facilities for visitors. • Commuter information boards identifying bicycle paths and public transit routes and schedules. Project applicant Prior to issuance of building permit Planning and Building Agency, Planning Division 2-10 Applicants for residential or residential mixed-use projects within: 1) 1,000 feet from the truck bays of an existing distribution centers that accommodate more than 100 trucks per day, more than 40 trucks with Project applicant Prepare HRA prior to approval of any future discretionary residential or Planning and Building Agency, Building Safety Division, Zoning Exhibit B to Exhibit 1 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 13 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) operating transport refrigeration units, or where transport refrigeration unit operations exceed 300 hours per week; or 2) 1,000 feet of an SCAQMD permitted facility, or an industrial facility which emits toxic air contaminants shall submit a health risk assessment (HRA) prepared in accordance with policies and procedures of the state Office of Environmental Health Hazard Assessment (OEHHA) and the South Coast Air Quality Management District (SCAQMD). The HRA shall be submitted to the Zoning Administrator prior to approval of any future discretionary residential or residential mixed-use project. If the HRA shows that the incremental cancer risk exceeds one in one hundred thousand (1.0E-05), PM concentrations would exceed 2.5 μg/m3, or the appropriate noncancer hazard index exceeds 1.0, the HRA shall identify the level of high-efficiency Minimum Efficiency Reporting Value (MERV) filter required to reduce indoor air concentrations of pollutants to achieve the cancer and/or noncancer threshold. The Applicant shall be required to install high efficiency MERV filters in the intake of residential ventilation systems, consistent with the recommendations of the HRA. Heating, air conditioning and ventilation (HVAC) systems shall be installed with a fan unit power designed to force air through the MERV filter. To ensure long-term maintenance and replacement of the MERV filters in the individual units, the following shall occur: • Developer, sale, and/or rental representative shall provide notification to all affected tenants/residents of the potential health risk for affected units. • For rental units, the owner/property manager shall maintain and replace MERV filters in accordance with the manufacture’s recommendations. The property owner shall inform renters of increased risk of exposure to diesel particulates when windows are open. • For residential owned units, the Homeowner’s Association (HOA) shall incorporate requirements for long-term maintenance residential mixed-use project; Installation of MERV filter requirements and maintenance prior to issuance of building permits Administrator Exhibit B to Exhibit 1 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements Page 14 PlaceWorks Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) in the Covenant Conditions and Restrictions and inform homeowners of their responsibility to maintain the MERV filter in accordance with the manufacturer’s recommendations. The HOA shall inform homeowners of increased risk of exposure to diesel particulates when windows are open. 5.3 CULTURAL RESOURCES 3-1 Prior to the issuance of grading permits, and for any subsequent permit involving excavation to increased depth, the project applicant for each development or redevelopment project considered for approval pursuant to the Harbor Boulevard Mixed Use Transit Corridor Plan shall provide letters to the City of Santa Ana from a qualified archaeologist and paleontologist (for excavations six feet below ground surface and deeper) who meet the Secretary of the Interior’s Professional Qualifications Standards. The letters shall state that the project applicant has retained these individuals, and that the consultant(s) will be on call during all grading and other significant ground-disturbing activities. In the event archeological or paleontological resources are discovered during ground-disturbing activities, the professional archeological or paleontological monitor shall have the authority to halt any activities adversely impacting potentially significant cultural resources until they can be formally evaluated. Suspension of ground disturbances in the vicinity of the discoveries shall not be lifted until the archaeological or paleontological monitor, in coordination with the construction contractor, has evaluated discoveries to assess whether they are significant cultural resources, pursuant to the California Environmental Quality Act (CEQA). If significance criteria are met, then the project shall be required to perform data recovery, professional identification, radiocarbon dates as applicable, and other special studies; they shall be offered for curation or preservation to a repository with a retrievable collection system and an educational and research interest in the materials, such as the Los Angeles County Museum of Natural History or California State University, Fullerton, or other local museum or repository. If no museum or repository is willing to accept the Project applicant Prior to issuance of grading permit Planning and Building Agency, Planning Division Exhibit B to Exhibit 1 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 15 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) resource, the resource shall be considered the property of the City, and may be stored, disposed of, transferred, exchanged, or otherwise handled by the City at its discretion. 5.6 HAZARDS AND HAZARDOUS MATERIALS 6-1 Prior to the issuance of demolition permits for any buildings or structures that would be demolished in conjunction with individual development projects that would be accommodated by the Harbor Boulevard Mixed Use Transit Corridor, the project applicant shall conduct the following inspections and assessments for all buildings and structures onsite and shall provide the City of Santa Ana’s Planning and Building Agency with a copy of the report of each investigation or assessment. • The project applicant shall retain a certified lead inspector/assessor to inspect buildings and structures onsite for lead-based paint (LBP). The inspector/assessor’s report shall include requirements for abatement, containment, and disposal of LBP, if encountered, in accordance with the State of California Occupational Safety & Health Administration Rule 29 CFR Part 1926. • The project applicant shall retain a licensed or certified asbestos consultant to inspect buildings and structures onsite for asbestos-containing materials (ACM). The consultant’s report shall include requirements for abatement, containment, and disposal of ACM, if encountered, in accordance with the South Coast Air Quality Management District’s Rule 1403. Project applicant Prior to issuance of demolition permit Planning and Building Agency, Building Safety Division 6-2 Prior to the issuance of grading permits for new development within the Harbor Boulevard Mixed Use Transit Corridor, the project applicant shall submit a Phase I Environmental Site Assessment (ESA) to identify environmental conditions and determine whether contamination is present. The Phase I ESA shall be prepared by a Registered Professional Engineer and in accordance with the American Society for Testing and Materials (ASTM) Standard E Project applicant Submit Phase I ESA prior to issuance of grading permit; Submit remediation documentation prior to issuance of building permit, if needed Building Official Exhibit B to Exhibit 1 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements Page 16 PlaceWorks Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) 1527.05, Standard Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process. If recognized environmental conditions related to soils are identified in the Phase I ESA, the project applicant shall perform soil sampling as a part of a Phase II ESA. If contamination is found at significant levels, the project applicant shall remediate all contaminated soils in accordance with state and local agency requirements (DTSC, RWQCB, Orange County Fire Authority, etc.). All contaminated soils and/or material encountered shall be disposed of at a regulated site and in accordance with applicable laws and regulations prior to the completion of grading. Prior to the issuance of building permits, a report documenting the completion, results, and any follow-up remediation on the recommendations, if any, shall be provided to the Building Official and the City of Santa Ana’s Planning and Building Agency evidencing that all site remediation activities have been completed. 5.7 HYDROLOGY AND WATER QUALITY 7-1 Prior to issuance of grading permits for future development projects in the Harbor Corridor Plan, applicants shall submit site-specific hydrology and hydraulic Studies to the Public Works Agency for review and approval. If existing facilities are not adequate to handle runoff generated by the proposed development, then the applicant shall construct storm drain improvements. Storm drain upgrades shall be implemented prior to issuance of occupancy permits. Project applicant Prior to issuance of grading permit Public Works Agency 7-2 During the design of individual projects, applicants shall minimize impervious area by incorporating landscaped areas over substantial portions of a proposed project area. Furthermore, impervious areas shall be directly connected to landscaped areas or bioretention facilities to promote filtration and infiltration of stormwater. The applicant must comply with the latest Orange County Model Water Quality Management Plan (WQMP). Project applicant Prior to issuance of grading permit Public Works Agency 7-3 Notice of Intent (NOI). Prior to the issuance of a grading permit for Project applicant Prior to issuance of grading Public Works Agency; City Exhibit B to Exhibit 1 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 17 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) construction sites with a disturbed area of one or more acres, the project applicant shall provide the City Engineer with evidence that a NOI has been filed with the State Water Resources Control Board. Such evidence shall consist of a copy of the NOI stamped by the State Water Resources Control Board or Regional Water Quality Control Board, or a letter from either agency stating that the NOI has been filed. permit Engineer 7-4 Storm Water Pollution Prevention Plan (SWPPP). Prior to the issuance of grading permits for construction sites with a disturbed area of one or more acres, the project applicant shall prepare a SWPPP that will: • Require implementation of best management practices (BMPs) designed with a goal of preventing a net increase in sediment load in stormwater discharges relative to preconstruction levels; • During the construction period, prohibit discharges of stormwater or non-storm water at levels which would cause or contribute to an exceedance of applicable water quality standards contained in the Basin Plan; • Discuss in detail the BMPs planned for the project related to control of sediment and erosion, nonsediment pollutants, and potential pollutants in non-storm water discharges; • Describe post-construction BMPs for the project; • Explain the maintenance program for the project’s BMPs; • During construction, require reporting of violations to the Regional Board; • List the parties responsible for SWPPP implementation and BMP maintenance during and after grading. The project proponent shall implement the SWPPP and will modify the SWPPP as directed by the Storm Water Permit. Project applicant Prior to issuance of grading permit Public Works Agency; City Engineer 7-5 Water Quality Management Plan (WQMP). Prior to the issuance of precise grading permits, project-specific WQMPs shall be submitted for review and approved by the Public Works Agency. The WQMP Project applicant Prior to issuance of precise grading permits Property Owner Exhibit B to Exhibit 1 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements Page 18 PlaceWorks Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) shall identify the best management practices (BMPs) that will be used on the site to control predictable pollutant runoff. More specifically, the WQMP shall: •Describe the routine and special post-construction BMPs to beused at the proposed development site (including both structuraland non-structural measures); •Describe responsibility for the initial implementation and long-term maintenance of the BMPs; •Provide narrative with the graphic materials as necessary tospecify the locations of the structural BMPs; •Certify that the project applicant will seek to have the WQMPcarried out by all future successors or assigns to the property. •The applicant must comply with the latest Orange County ModelWater Quality Management Plan (WQMP). 7-6 Prior to the issuance of precise grading permit for any lot or parcel wholly or partially located within the 100-year floodplain, the applicant shall furnish to the Building Official documentation required by FEMA for approval of the Conditional Letter of Map Revision/Letter of Map Revision (CLOMR/LOMR) process. The FEMA for revision to the FIRM and Flood Insurance Study (FIS). The applicant shall pay all preliminary and subsequent fees as required by FEMA. Project applicant Prior to issuance of precise grading permit Building Official 5.9 NOISE 9-1 Prior to issuance of a building permit, applicants for new residential development in the Harbor Corridor Plan shall submit an acoustic report prepared to the satisfaction of the Building Official or their designee to ensure that noise levels at outdoor living areas such as private yards, balconies, and park picnic areas shall not exceed 65 dBA CNEL, and all residential habitable rooms would meet the 45 dBA CNEL interior noise standard. These noise studies would need to be submitted after the precise grading and architectural plans are prepared, but prior to issuance of building permits. The required Project applicant Prior to issuance of building permit Planning and Building Agency, Building Safety Division Exhibit B to Exhibit 1 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 19 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) exterior noise reduction can be accomplished with sound walls or berms, or by site plan/building layout design. The required interior noise reduction can be accomplished with enhanced construction design or materials such as upgraded dual-glazed windows and/or upgraded exterior wall assemblies. These features shall be shown on all building plans and incorporated into construction of the project. City inspectors shall verify compliance of the building with the acoustic report’s recommendations prior to issuance of a Certificate of Occupancy. 9-2 Prior to issuance of a building permit, applicants for new commercial, office, or retail developments in the Harbor Corridor Plan shall submit an acoustic report prepared to the satisfaction of the Zoning Administrator and Building Official or their designee to ensure that the operation of stationary noise sources (i.e., HVAC units, truck deliveries) would not cause a noise increase of more than 5 dBA over the ambient noise levels at any adjacent property. These noise studies would need to be submitted after the precise grading and architectural plans are prepared, but prior to issuance of building permits. This requirement can be accomplished with selection of quieter equipment, judicious site layouts and equipment positioning, and/or equipment enclosures, sound screening, or parapet walls. These features shall be shown on all building plans and incorporated into the construction of the project. City inspectors shall verify compliance of the building with the acoustic report’s recommendations prior to issuance of a Certificate of Occupancy. Project applicant Prior to issuance of building permit; prior to issuance of certificate of occupancy Planning and Building Agency, Zoning Administrator and Building Official or designee 9-3 Prior to issuance of a building permit, applicants for projects within the Harbor Corridor Plan that involve high-vibration construction activities, such as pile driving or vibratory rolling/compacting, shall be evaluated for potential vibration impacts to nearby sensitive receptors. The project developer shall submit a vibration report prepared to the satisfaction of the City of Santa Ana Building Official or their designee to determine if the use of pile driving and/or vibratory rolling/compacting equipment would exceed the Federal Transit Project applicant Prior to issuance of building permit Planning and Building Agency, Building Official or designee Exhibit B to Exhibit 1 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements Page 20 PlaceWorks Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) Administration’s (FTA’s) vibration-annoyance criteria of 78 VdB during the daytime or FTA’s vibration-induced architectural damage PPV criteria of 0.2 inches/second for wood-framed structures or 0.5 inches/second for reinforced masonry buildings. The construction contractor shall require the use of lower-vibration-producing equipment and techniques. Examples of lower-vibration equipment and techniques would include avoiding the use of vibratory rollers near sensitive areas and/or the use of drilled piles, sonic pile driving, or vibratory pile driving (as opposed to impact pile driving). 9-4 Prior to issuance of grading permits, the project applicant shall ensure the following notes are included on the grading plan cover sheet, and the construction contractor shall comply with these measures during the duration of all construction activities. • Properly maintain and tune all construction equipment to minimize noise. • Fit all equipment with properly operating mufflers, air intake silencers, and engine shrouds, no less effective than as originally equipped by the manufacturer, to minimize noise emissions. • Locate all stationary noise sources (e.g., generators, compressors, staging areas) as far from noise-sensitive receptors as possible. Material delivery, soil haul trucks, and equipment servicing shall be restricted to the hours between 7:00 AM and 8:00 PM Mondays through Saturdays, and not at all on Sundays or federal holidays. Project applicant Prior to issuance of grading permit Planning and Building Agency, Planning Division 9-5 Prior to the issuance of grading permits, each project applicant within the project area shall prepare a construction management plan that shall be approved by the City of Santa Ana Public Works. The construction management plan shall: • Establish truck haul routes on the appropriate transportation facilities. Truck routes that avoid congested streets and sensitive land uses shall be considered. Project applicant Prior to issuance of grading permit Public Works Agency Exhibit B to Exhibit 1 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 21 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) •Provide Traffic Control Plans (for detours and temporary roadclosures) that meet the minimum City criteria. Traffic controlplans shall determine if dedicated turn lanes for movement ofconstruction truck and equipment on- and offsite are available. •Minimize offsite road closures during the peak hours. •Keep all construction-related traffic onsite at all times. •Provide temporary traffic controls, such as a flag person, duringall phases of construction to maintain smooth traffic flow. 5.13 TRANSPORTATION AND CIRCULATION 13-1 Prior to the issuance of building permits, the project applicant shall evaluate the potential for any neighborhood cut through traffic. Neighborhood cut through traffic shall be minimized through implementation of traffic calming measures as approved by the Public Works Agency. Project applicant Prior to the issuance of building permit Public Works Agency 13-2 The City of Santa Ana shall implement a program for traffic improvements in the Harbor Corridor Plan. The program shall prescribe the method of participation in the mitigation program by individual projects and guide the timely implementation of mitigation measures. The program shall include the following elements: •A funding and improvement program should be established toidentify financial resources adequate to construct all identifiedmitigation measures in a timely basis. •All properties that redevelop within the Harbor Corridor Planshould participate in the program on a fair share per newdevelopment trip basis. The fair share shall be based upon thetotal cost of all identified mitigation measures (see MitigationMeasure 13-3), divided by the peak hour trip generation increaseforecast. This rate per peak hour trip should be imposed uponthe incremental traffic growth for any new development withinthe Harbor Corridor Plan. •The project shall raise fund from full development of the Harbor City of Santa Ana On-going monitoring Public Works Agency Exhibit B to Exhibit 1 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements Page 22 PlaceWorks Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) Corridor Plan to fund all identified mitigation measures. • The project shall monitor phasing development of the Harbor Corridor Plan and defer or eliminate improvements if the densities permitted in the Harbor Corridor Plan are not occurring. • Program phasing shall be monitored through preparation of specific project traffic studies for any project that is expected to include more than 100 dwelling units or 100,000 sf of non-residential development. Traffic impact studies should use traffic generation rates that are deemed to be most appropriate for the actual development proposed. • The City may elect to implement appropriate mitigation measures as a condition of approval of the proposed developments, where appropriate. All or part of the costs of these improvements may be considered to be a negotiated credit toward the program, however the program must be administered in a manner that assures that it can fund necessary improvements to maintain adequate level of service at all intersections within the study. If funding of priority improvements cannot be assured, credit for construction of lower priority improvements may not be assured or may be postponed until more program funds are available. 13-3 Prior to the issuance of building permits, the project applicant shall participate in the program for traffic improvements in the Harbor Corridor Plan per MM 13-2. The traffic improvement program includes the following improvements: • Intersection #26: Fairview Street and 17th Street (Year 2035) o Improvements are to add a northbound through lane. • Intersection #27: Fairview Street and 1st Street (Year 2035) o Improvements are to add a southbound right-turn lane. Project applicant Prior to issuance of building permit Public Works Agency 5.14 UTILITIES AND SERVICE SYSTEMS 7-1 Mitigation Measure 7-1 applies. See Hydrology and Water Quality section, above. Exhibit B to Exhibit 1 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 23 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) 14-1 Prior to the first building permit pursuant to the proposed project, the City of Santa Ana shall prepare a “Nexus” Study that will serve as the basis for requiring development impact fees under AB 1600 legislation, as codified by California Code Government Section 66000 et seq. The established procedures under AB 1600 require that a “reasonable relationship” or nexus exist between the water and sewer infrastructure improvements and facilities required to mitigate the sewer impacts of new development pursuant to the proposed project. The sewer segment improvements shown on Table 5.14-11 of the DEIR are necessary to mitigate project impacts and shall be included, among other improvements, in the AB 1600 nexus study. City of Santa Ana Prior to issuance of first building permit Public Works Agency 14-2 Prior to the issuance of the first building permit pursuant to the proposed project, the City of Santa Ana shall prepare a Development Fee program pursuant to the AB 1600 Nexus Study identified in Mitigation Measure 14-1, above. The Development Fee program would fund the Harbor Corridor Plan area-wide water and sewer infrastructure improvements. The fee program shall stipulate that fees are assessed when there is new construction or when there is an increase in square footage within an existing building or the conversion of existing square footage to a more intensive use. Fees are calculated by multiplying the proposed square footage or dwelling unit by the rate identified. The fees are included with any other applicable fees payable at the time the building permit is issued. The City will use the development fees to fund construction (or to recoup fees advanced to fund construction) of the infrastructure improvements identified in Mitigation Measure 14-1. City of Santa Ana Prior to issuance of first building permit Public Works Agency 14-3 Prior to the issuance of a grading permit, the project applicant shall prepare water and sewer studies and identify the sizing and location of backbone facilities necessary to serve the proposed project, in accordance with City standards. The water and sewer plans shall be submitted to the City’s Public Works Agency for review and approval. Design of facilities that serve the project shall be sufficient to meet the projected service demands. Project applicant Prior to issuance of a grading permit Public Works Agency Exhibit B to Exhibit 1 Prepared by: Megan A. Lam Transportation Engineer Ill TRAFFIC AND PARKING ANALYSIS FIRST HARBOR MIXED-USE PROJECT Santa Ana, California October 23, 2023 Prepared for: HARBOR & FIRST, LLC 750 N. Diamond Bar Boulevard, Suite 101 Diamond Bar, CA 91765 LLG Ref. 2.23.4737.1 Under the Supervision of: Trissa de Jesus Allen, P.E., RSP Senior Transportation Engineer LINSCOTT LAW & GREENSPAN engineers Linscott. law& Greenspan. Engineers 2 Executive Circle Suite 2.50 lrvme.CA9Z614 949.825.6175 T 9QS.825.6l73 F w1Mv.llgeng,neers.com Exhibit C to Exhibit 1 TABLE OF CONTENTS SECTION PAGE 1.0 Introduction ................................................................................................................................. 1 I.I Scope ofWork ...................................................................................................................... l 1.2 Study Area ............................................................................................................................ 2 2.0 Project Description ..................................................................................................................... 3 2.1 Site Access ............................................................................................................................ 3 2.2 Pedestrian and Bicycle Circulation ....................................................................................... 3 3.0 Existing (2023) Conditions ......................................................................................................... 4 3. I Existing Street System .......................................................................................................... 4 3.2 Existing Traffic Volumes ...................................................................................................... 4 3.3 Existing Public Transportation ............................................................................................. 5 3.4 Existing Intersection Conditions ........................................................................................... 6 3.4.1 Intersection Capacity Utilization (ICU) Method of Analysis ..................................... 6 3.4.2 Highway Capacity Manual (HCM) Method of Analysis (Unsignalized Intersections) ....................................................................................... 6 3.4.3 Level of Service Criteria ............................................................................................. 9 3 .5 Existing Level of Service Results ......................................................................................... 9 4.0 Traffic Forecasts ....................................................................................................................... 11 4.1 Project Traffic Generation .................................................................................................. 12 4.2 Project Traffic Distribution and Assignment.. .................................................................... 12 4.3 Existing Plus Project Traffic Volumes ............................................................................... 14 4.4 Year2028 Cumulative Base ............................................................................................... 14 4.4.1 Ambient Traffic Growth ........................................................................................... 14 4.4.2 Cumulative Projects .................................................................................................. 14 4.4.3 Year 2028 Cumulative Base Traffic Volumes .......................................................... 17 4.4.4 Year 2028 Cumulative Plus Project Traffic Volumes .............................................. 17 5.0 Non-CEQA Traffic Analysis .................................................................................................... 18 5.1 LOS Standards and Thresholds ........................................................................................... 18 5 .2 Traffic Analysis Scenarios .................................................................................................. 18 5.3 Existing (2023) Plus Project Traffic Conditions ................................................................. 19 5 .4 Year 2028 Traffic Conditions ............................................................................................. 21 5.4.1 Year 2028 Cumulative Base Traffic Conditions ....................................................... 21 5.4.2 Year 2028 Cumulative Plus Project Conditions ....................................................... 21 6.0 Site Access and Internal Circulati6n Evaluation ................................................................... 23 6.1 Site Access .......................................................................................................................... 23 6.1.1 Traffic Gap Assessment ............................................................................................ 25 6.2 Internal Circulation Evaluation ........................................................................................... 28 6.3 Sight Distance Evaluation ................................................................................................... 28 LINSCOTT, LAW & GREENSPAN, engineers LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N· ·.+70(11:Z:ZH7J7. F,r,t H:i,bor ;\,l11.ed t:s�. S:111ta Ana'R,:po,rl47J7 F11-s1 lfarbor �lu;�d-Us�, Santa ,-\na Traffic Stl1dy 10-2J-2J doc Exhibit C to Exhibit 1 TABLE OF CONTENTS (CONTINUED) SECTION PAGE 7.0 Intersection Turn Pocket Queuing Analysis ........................................................................... 30 8.0 Congestion Management Program (CMP) Compliance Assessment ................................... 34 9.0 Roadway Segment Evaluation ................................................................................................. 35 9.1 Roadway Link Capacities ................................................................................................... 35 9.2 Roadway Link Level of Service Criteria ............................................................................ 35 9.3 Roadway Segment Analysis Results ................................................................................... 37 9.3.1 Existing Plus Project Analysis .................................................................................. 37 9.3.2 Year 2028 Plus Project Analysis ............................................................................... 39 10.0 CEQA Assessment ofVMT, Active Transportation, & Public Transit ............................... 41 IO.I Vehicle Miles Traveled (VMT) Screening Analysis .......................................................... 41 10.2 Active Transportation and Public Transit Screening Analysis ........................................... 41 11.0 Parking Analysis and Parking Management Plan (PMP) ..................................................... 43 1 I. 1 City Code Parking Requirements ........................................................................................ 43 11.2 Parking Management Plan (PMP) ...................................................................................... 43 11.3 PMP Measures .................................................................................................................... 45 12.0 Summary Of Findings And Conclusions ................................................................................ 48 LINSCOTT, LAW & GREENSPAN, engineers ii LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N·;.170{1111J--17J7 -Fu;t 1--farbor Mi"ed lls.:, S;J.11t;i Ana'R�porN7J7 first H:ubor �IJ>.�d-L'�. Santa Ana Traffie Study I0-2J-2J doc Exhibit C to Exhibit 1 APPENDIX A.Existing Traffic Count Data APPENDICES B.Intersection Level of Service Calculation WorksheetsC.Project Driveway Level of Service Calculation WorksheetsD.Queuing Calculation WorksheetsLINSCOTT, LAW & GREENSPAN, engineers iii LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit C to Exhibit 1 LIST OF FIGURES SECTION-FIGURE# FOLLOWING PAGE 1-1 Vicinity Map ..................................................................................................................... 2 2-1 Existing Site Aerial ........................................................................................................... 3 2-2 Proposed Site Plan ............................................................................................................ 3 3-1 Existing Roadway Conditions and Intersection Controls ............................................. .4 3-2 Existing AM Peak Hour Traffic Volumes ...................................................................... 5 3-3 Existing PM Peak Hour and Daily Traffic Volumes ..................................................... 5 4-1 Project Traffic Distribution Pattem ................................................................................ 13 4-2 AM Peak Hour Project Traffic Volumes ...................................................................... 13 4-3 PM Peak Hour and Daily Project Traffic Volumes ..................................................... 13 4-4 Existing Plus Project AM Peak Hour Traffic Volumes ............................................... 14 4-5 Existing Plus Project PM Peak Hour and Daily Traffic Volumes .............................. 14 4-6 Location of Cumulative Projects .................................................................................... 15 4-7 AM Peak Hour Cumulative Projects Traffic Volumes .................................................. 17 4-8 PM Peak Hour and Daily Cumulative Projects Traffic Volumes .................................. 17 4-9 Year 2028 AM Peak Hour Cumulative Base Traffic Volumes ................................... 17 4-10 Year 2028 PM Peak Hour and Daily Cumulative Base Traffic Volumes .................. 17 4-11 Year 2028 AM Peak Hour Cumulative Plus Project Traffic Volumes ....................... 17 4-12 Year 2028 PM Peak Hour and Daily Cumulative Plus Project Traffic Volumes ...... 17 6-1 Harbor Boulevard Sight Distance Analysis .................................................................. 29 6-2 Figueroa Street Sight Distance Analysis ...................................................................... 29 6-3 Figueroa Street at I st Street SBR Sight Distance Analysis ......................................... 29 6-4 Figueroa Street at 1st Street SBL Sight Distance Analysis .......................................... 29 10-1 Santa Ana Transit Priority Areas ................................................................................. .41 10-2 VMT/SP in Santa Ana as Compared to Orange County Average ............................. .41 10-3 Santa Ana Development Areas that Cannot Be Screened .......................................... .41 LINSCOTT, LAW & GREENSPAN, engineers iv LLG Re[ 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N \47D(J122J47J7 -first Harbor �{1>.cd ll�. Santa AnalR�µo, 114737 F11s1 H:ubor ;\.IJ><�d-U�. S'-'llta .\n:1. Tralli.c Study J().2J.2J.<loc Exhibit C to Exhibit 1 LIST OF TABLES SECTION-TABLE# PAGE 3-1 Level of Service Criteria For Signalized Intersections (ICU Methodology) ............... 7 3-2 Level of Service Criteria For Unsignalized Intersections (HCM Methodology) ......... 8 3-3 Existing Peak Hour Intersection Capacity Analysis ....................................................... 10 4-1 Project Traffic Generation Forecast. ............................................................................... 13 4-2 Location and Description of Cumulative Projects .......................................................... 15 4-3 Cumulative Projects Traffic Generation Forecast .......................................................... 16 5-1 Existing Plus Project Peak Hour Intersection Capacity Analysis .................................. 20 5-2 Year 2028 Peak Hour Intersection Capacity Analysis ................................................... 22 6-1 Project Driveway Peak Hour Intersection Capacity Analysis ....................................... 24 6-2 Right-Tum Out Vehicle Gap Analysis .......................................................................... 26 6-3 Left-Tum Out Vehicle Gap Analysis ............................................................................ 27 7-1 Existing Plus Project Queuing Analysis ........................................................................ 32 7-2 Year 2028 Cumulative Plus Project Queuing Analysis ................................................ 33 9-1 Roadway Segment Capacities and Level of Service Criteria ......................................... 36 9-2 Existing Plus Project Roadway Segment Level of Service Summary ........................... 38 9-3 Year2028 Cumulative Plus Project Roadway Segment Level of Service Summary .... 40 11-1 City Code Parking Requirements .................................................................................. .44 LINSCOTT, LAW & GREENSPAN, engineers V LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N:,-17001:234737. F,r�t H:t1bor ;..i,��d l!sc, S:mta ,\i,J'R�porN7J7 F11'."t !farMr \lv,�d-l'�. S:intJ .\n:t Traffic Stud) I0-2J-2J.doe Exhibit C to Exhibit 1 1.0 INTRODUCTION TRAFFIC AND PARKING ANALYSIS FIRST HARBOR MIXED-USE PROJECT Santa Ana, California October 23, 2023 This Traffic and Parking Analysis was conducted by Linscott, Law & Greenspan, Engineers (LLG) to determine and evaluate the potential traffic circulation and parking needs associated with the First Harbor Mixed-Use Project, which is the development of a nine-story building with 183 multifamily residential units (including studios, I-bedroom, 2-bedroom, and 3-bedroom units) and 15,182 square feet (SF) of retail on the ground floor, as proposed by Harbor & First, LLC. Of the 183 total units proposed, 15% (28 units) would be designated as low-income housing. The residential and retail uses would wrap around a four-level parking structure, consisting of two subterranean levels, one street/ground level, and a second above-ground level, and provide a total of 333 standard parking spaces. The Project site, which is currently vacant, is located on the north side of I st Street, between Harbor Boulevard and Figueroa Street, at IO I North Harbor Boulevard in the City of Santa Ana, California. The Project site exists within a Specific Plan district regulated by the Harbor Mixed Use Transit Corridor Plan; specifically, the South Transit Node District, which is comprised of the properties surrounding the Bravo Bus Rapid Transit (BRT) stations at Harbor Boulevard and 1st Street, and at Harbor Boulevard and McFadden Avenue. The South Transit Node generally anticipates three- to six-story buildings within the District, with the flexibility to allow IO stories, and has an emphasis on mixed-use development. Based on this, the Project, as proposed with nine stories and a mix of uses, is consistent with the land use plan for the South Transit Node District the Project site is located in. 1.1 Scope of Work Based on close coordination with City staff, and staying consistent with the City of Santa Ana Traffic Impact Study Guidelines (September 20 I 9), this report presents a non-CEQA transportation assessment, including an inventory of existing characteristics and traffic volumes during the AM and PM peak commute periods at key locations within the study area, forecasts of vehicular traffic anticipated to be generated by the Pr oject, evaluation of potential non-CEQA impacts of Project generated trips on the surrounding street system under Year 2028 conditions (i.e., the anticipated completion year for the Project), and site access and internal circulation analysis. As described in the City's traffic impact study guidelines, this report also provides a CEQA assessment (Project screening) of VMT, active transportation, and public transit. In addition, the last section of this report presents the parking analysis and Parking Management Plan (PMP) prepared for the Project. LINSCOTT, LAW & GREENSPAN, engineers 1 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana :,,: ,4700\2�H7J7-Fm;! H:ubor \11>.eJ Use. S:mt� Aoa'R�po•t1,1737 First 11:!rl>or Mi,.,ed-l'se, Sanu .\n:t Traffic Stud, 10-23-lJ do<" Exhibit C to Exhibit 1 1.2 Study Area Two (2) key study intersections and one (I) key roadway segment have been identified for evaluation. The two (2) intersections/one (I) roadway segment listed below provide regional and local access to the study area and define the extent of the boundaries for this traffic investigation. Kev Study Intersections 1.Harbor Boulevard at 5th Street (City of Santa Ana)2.Harbor Boulevard at I st Street (City of Santa Ana) Kev Roadway Segment A.Figueroa Street, between 5th Street and I st Street (City of Santa Ana) Figure 1-1 presents a Vicinity Map, which illustrates the general location of the Project and depicts the study locations and surrounding street system. The Level of Service (LOS) investigations at these key locations were used to evaluate the potential traffic circulation needs associated with area growth, cumulative projects, and the proposed Project. LINSCOTT, LAW & GREENSPAN, engineers 2 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana :>ht70{1111H7J7 -F,rs, H;ubor :\ltx.:d US<!. SantJ Ana'R,:1>01 t147J7 f115\ H.ubor :\{1�,:d-VS<:. Sa11r.1 .\na Traffic StuJy 10-23-23.<loc Exhibit C to Exhibit 1 W 5th St a 0• % l t S! t z :i: i GIi I SOURCE: GOOGLE KEY a (j) • STUDY INTERSECTION [?J = PROJECT SITE z f i 6L1Sl lQ ;z i w =Z W llll St ll: I � w SI W1stSt fl FIGURE 1-1 VICINITY MAP FIRST HARBOR MIXED-USE PROJECT, SANTA ANA i � � 1 � � Exhibit C to Exhibit 1 2.0 PROJECT DESCRIPTION The First Harbor Mixed-Use Project proposes to develop a nine-story building with 183 multifamily residential units (including studios, I-bedroom, 2-bedroom, and 3-bedroom units) and 15,182 SF of retail on the ground floor. Of the 183 total units proposed, 15% (28 units) would be designated as low-income housing. The residential and retail uses would wrap around a four-level parking structure, consisting of two subterranean levels, one street/ground level, and a second above-ground level, and provide a total of333 standard parking spaces. As presented previously, Figure 1-1 is the Vicinity Map, which shows the general location of the Project and surrounding street system. Figure 2-1 is an existing aerial photograph of the Project site. The Project is expected to be completed and fully occupied by Year 2028. As part of the Project-specific improvements planned at the intersection of Harbor Boulevard and I st Street (Intersection No. 2) previously approved by the City, the Project will be adding a right-tum pocket (with a total length of 213 feet, comprised of 186 feet of storage length, and 27 feet of transition length) along 1st Street on the westbound approach of the intersection. 2.1 Site Access Access to the Project will be provided via one (I) right-tum in/out only driveway on Harbor Boulevard and two (2) driveways restricted to left-turns/right-turns in, and right-turns out, on Figueroa Street. 2.2 Pedestrian and Bicycle Circulation Sidewalks are provided on both sides of the street throughout most of the City. Crosswalks, pedestrian push buttons, and pedestrian indication lights are provided at all signalized intersections adjacent to the Project site. The proposed Project plans to retain this existing pedestrian infrastructure. The proposed Project will encourage walking by integrating pedestrian connections internally, as well as to nearby activities. Pedestrian circulation would be provided via existing public sidewalks along Harbor Boulevard, I st Street, and Figueroa Street within the vicinity of the Project. The proposed Project will protect the existing sidewalk along Project frontage on these roadways. The existing sidewalk system within the Project vicinity provides direct connectivity to the existing development located along major thoroughfares. Long-term bicycle storage for the residential and retail uses will be provided in two bike rooms, totaling 96 long-term bike spaces. An additional four ( 4) bicycle spaces will be provided for short term bicycle storage purposes. According to the City of Santa Ana Bikeway Master Plan, Class IV Cycle Tracks are planned on Harbor Boulevard and I st Street along the Project's frontage. LINSCOTT, LAw&GREENSPAN, engineers 3 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit C to Exhibit 1 SOURCE: GOOGLE KEY [Z-:.:zl = PROJECT SITE FIGURE 2-1 EXISTING SITE AERIAL FIRST HARBOR MIXED-USE PROJECT, SANTA ANA Exhibit C to Exhibit 1 .. I• I -, .,;·., i i· ! I t � lI , -t _:II ]Gi t;I ; gi, . �, .0 w , �i .,;, I! :�. l -' i 1 r· i ... l ---+----------{-------W.FlRSTSTREl."T _________________ +---j I SOURCE: PRIMIOR FIGURE 2-2 PROPOSED SITE PLAN FIRST HARBOR MIXED-USE PROJECT, SANTA ANA Exhibit C to Exhibit 1 3.0 EXISTING (2023) CONDITIONS 3.1 Existing Street System The principal local network of streets serving the project site are Harbor Boulevard, 1 st Street, 5th Street and Figueroa Street. The following discussion provides a brief synopsis of these key area streets. The descriptions are based on an inventory of existing roadway conditions. Harbor Boulevard is generally a six-lane, divided roadway that borders the Project site to the west, oriented in the north-south direction that provides three northbound and three southbound travel lanes separated by a raised median. Harbor Boulevard will provide one (I) right-in/right-out driveway for the proposed Project. The posted speed limit on Harbor Boulevard is 40 miles per hour (mph). On-street parking is not permitted along this roadway in the vicinity of the project. The City of Santa Ana General Plan Circulation Element classifies Harbor Boulevard as a Major Arterial. Class II Buffered Bike Lanes are provided south of 1st Street in the vicinity of the project. Traffic signals control the study intersections of Harbor Boulevard at 5th Street and ]st Street. 1st Street is generally a six-lane, divided roadway that borders the Project site to the south, oriented in the east-west direction that provides three lanes in each direction separated by a TWL T striped median. The posted speed limit on I st Street is 40 mph. On-street parking is not permitted along this roadway in the vicinity of the project. The City of Santa Ana General Plan Circulation Element classifies 1st Street as a Major Arterial. Class II Buffered Bike Lanes are provided west of Harbor Boulevard in the vicinity of the project. 5th Street is generally a four-lane divided roadway east of Harbor Boulevard and a two-lane undivided roadway west of Harbor Boulevard, oriented in the east-west direction. The posted speed limit is 35 mph east of Harbor Boulevard and 30 mph west of Harbor Boulevard. On-street parking is only permitted on the north side of this roadway east of Harbor Boulevard in the vicinity of the project. The City of Santa Ana General Plan Circulation Element classifies 5th Street as a Secondary Arterial east of Harbor Boulevard and a Commuter west of Harbor Boulevard. Figueroa Street is a two-lane undivided roadway that borders the Project site to the east, oriented in the north-south direction. The prima facie speed limit is 25 mph and parking is permitted on both sides of the roadway. Figueroa Street will provide two (2) left-tum/right-turns in and right-tum out only driveways for the proposed Project. Figure 3-1 presents an inventory of the ex1stmg roadway conditions for the arterials and intersections evaluated in this report. This figure identifies the number of travel lanes for key arterials, as well as intersection configurations and controls for the key area study intersections. 3.2 Existing Traffic Volumes Two (2) key study intersections and one (1) key roadway segment have been identified as the locations at which to evaluate existing and future traffic operating conditions. Some portion of potential project-related traffic will pass through each of these intersections, and their analysis will reveal the potential need for Project-related circulation improvements. These key locations were LINSCOTT, LAW & GREENSPAN, engineers 4 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit C to Exhibit 1 2U 5TH l30J 60 1ST l 4-0J NO SCALE 8 PHASE SIGNAL L 4i++l.) - NP ' 40 NP _J itt�l35J t ..., G) C �gi l"'1 ;;o 0 ..... l> NN CJIC l> ..... ;;o CD 0 ;;o "U "U �� (/) -f t::. ·::. ·::. ·::. ·::) I ............. -�.............. . . . . . . . . . . . . . . :-:-:-:-:-:-:-:-:-:-:-:-:-:-] 8 PHASE �············1SIGNAL ........... ........... ........... ]..JU+� ........... Ji,-• .......... NP ............ ...., NP :!J ittti ----t �gi ..... r cS �� KEY - = APPROACH LANE ASSIGNMENTe= TRAFFIC SIGNAL, -r = STOP SIGN P = PARKING, NP = NO PARKING ST p NP 1m ST IJP ( 4-0) NP FIGURE 3-1 U = UNDIVIDED, D = DIVIDED 2 = NUMBER OF TRAVEL LANES (XX)= POSTED SPEED LIMIT (MPH) ma -PROJECT SITE EXISTING ROADWAY CONDITIONS AND INTERSECTION CONTROLS FIRST HARBOR MIXED-USE PROJECT, SANTA ANA i ,,, N N .!. ' S? ..... 0 ,,, � 0.. 9 "' • '! ' !:? ...,,,... / "' • / 0 0 " :l =� "ll -�I "' I ... ... N N / c Exhibit C to Exhibit 1 selected for evaluation based on discussions with City of Santa Ana staff and in consideration of Orange County CMP requirements. Existing daily, AM peak hour and PM peak hour traffic volumes for the two (2) key study intersections and one (I) key roadway segment evaluated in this report were obtained from manual turning movement counts conducted by Transportation Studies, inc. in August 2023. Figures 3-2 and 3-3 illustrate the existing AM and PM peak hour traffic volumes at the two (2) key study intersections evaluated in this report, respectively. Figure 3-3 also presents the existing average daily traffic volumes for the one (I) key roadway segment in the vicinity of the proposed Project. Appendix A contains the detailed peak hour and daily traffic count sheets for the key intersections and roadway segments evaluated in this report. 3.3 Existing Public Transportation Public transit bus service is provided in the project area by the Orange County Transportation Authority (OCTA). Figure 1-1 identifies the bus stop locations nearest to the Project site. Three (3) OCT A bus routes operate within the vicinity of the Project site on Harbor Boulevard and I st Street, which consist of the following: •OCTA Route 43 (Fullerton to Costa Mesa): Route 43 is a local bus route serving the Cities of Fullerton, Anaheim, Garden Grove, Santa Ana, Fountain Valley and Costa Mesa. The major route of travel is along Harbor Boulevard in the vicinity of the project. Route 43 connects to the Fullerton Transportation Center, approximately 13.8 miles from the Project site, which also connects to OCTA Routes 26, 47, 143, and 543 as well as Metrolink/Amtrak. Route 43 operates on approximately 20-minute headways during weekdays and 15-minute headways on weekends. Nearest to the project site are bus stops on Harbor Boulevard -northbound and southbound, south of pt Street. The northbound bus stop is located approximately 210 feet from the Project site and the southbound bus stop is located approximately 460 feet from the Project site. •OCTA Route 64 (Huntington Beach to Tustin): Route 64 is a local bus route serving the Cities of Tustin, Santa Ana, Garden Grove, Westminster, Midway City and Huntington Beach. The major route of travel is along I st Street in the vicinity of the project. Route 64 operates on approximately IS-minute headways during weekdays and 20-minute headways on weekends. Nearest to the project site are bus stops on I st Street -eastbound and westbound, at its intersection with Harbor Boulevard. The eastbound bus stop is located approximately 210 feet from the Project site and the westbound bus stop is located approximately 230 feet from the Project site. •OCTA Route 543 (Fullerton Transportation Center to Santa Ana): Route 543 is a Bravo route serving the Cities of Fullerton, Anaheim, Garden Grove, Santa Ana and Costa Mesa. The major route of travel is along Harbor Boulevard in the vicinity of the project. Route 543 connects to the Fullerton Transportation Center, approximately 13 .8 miles from the Project site, which also connects to OCTA Routes 26, 43, 47, and 143 as well as Metrolink/Amtrak. Route 543 operates LINSCOTT, LAW & GREENSPAN, engineers 5 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit C to Exhibit 1 LINSCOTT LAW & GREENSPAN engineers 5TH 1ST �O SCALE ..,. co--0>1n co--) I l 94_,I 138-76, \.._ 163 -921.-139)l.( �co ::i: )> ;:o (D 0 ;:o r. '::. '::. ·::. ·:::ir ..............I.............. ,.............. :-:-:-:-:-:-:-:-:-:-:-:-:-:-] -:-:-:-:-:-:-:-:-:-:-:-:-:-:1 :-:-:-:-:-:-:-:-:-:-:-:-:-:-] ... · ·.·;.:,,,,,·;_;,,,,·�-. •. KEY [fil:fil = PROJECT SITE ST ::!l G) C rr, ;:o 0 )> ST FIGURE 3-2 EXISTING AM PEAK HOUR TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA ::l l;l I 8 I 0 "-9 .......,I C Exhibit C to Exhibit 1 LINSCOTT LAW & GREENSPAN engineers 5TH 1ST IO �a� Jll 55J 130-65, \,_ 269 -211, 114 �kf ,-...� :r )> ;o CD 0 ;o r-:. ·::. ·::. ·::: ·::J t ·:-:-:-:-:-:-:-:-:-:-:-:-:-:4 :-:-:-:-:-:-:-:-:-:-:-:-:-:-] -:-:-:-:-:-:-:-:-:-:-:-:-:-:➔ :-:-:-:-:-:-:-:-:-:-:-:-:-:-] ··.·:..:_.·�······.1 KEY ..,S&!L = DAILY TRAFFIC VOLUMES � = PROJECT SITE ,, G) C fTl ;o 0 )> ,� (/) -i ST ST FIGURE 3-3 EXISTING PM PEAK HOUR AND DAILY TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA .., N 0 N I I 0 ., N N .., s 9 "' • .., ,.; I !;! Exhibit C to Exhibit 1 on approximately 25-minute headways during weekdays and is closed on the weekends. Nearest to the project site are bus stops on Harbor Boulevard - northbound and southbound, south of I st Street. The northbound bus stop is located approximately 210 feet from the Project site and the southbound bus stop is located approximately 460 feet from the Project site. 3.4 Existing Intersection Conditions Existing AM and PM peak hour operating conditions for the two (2) key study intersections were evaluated using the Intersection Capacity Utilization (ICU) methodology for signalized intersections and the methodology outlined in the Highway Capacity Manual 6 (HCM 6) for unsignalized intersections (i.e. project driveways). 3.4.1 Intersection Capacity Utilization (ICU) Method of Analysis In conformance with City of Santa Ana requirements, existing AM and PM peak hour operating conditions for the key signalized study intersections were evaluated using the Intersection Capacity Utilization (ICU) method. The ICU technique is intended for signalized intersection analysis and estimates the volume to capacity (Y/C) relationship for an intersection based on the individual V/C ratios for key conflicting traffic movements. The ICU numerical value represents the percent signal (green) time, and thus capacity, required by existing and/or future traffic. It should be noted that the ICU methodology assumes uniform traffic distribution per intersection approach lane and optimal signal timing. Per City of Santa Ana requirements, the ICU calculations use a lane capacity of 1,700 vehicles per hour (vph) for through lanes and 1,600 vph for left-tum lanes and right-tum lanes. A clearance adjustment factor of 0.05 was added to each Level of Service calculation. The ICU value translates to a Level of Service (LOS) estimate, which is a relative measure of the intersection performance. The ICU value is the sum of the critical volume to capacity ratios at an intersection; it is not intended to be indicative of the LOS of each of the individual turning movements. The six qualitative categories of Level of Service have been defined along with the corresponding ICU value range and are shown in Table 3-1. 3.4.2 Highway Capacity Manual (HCM) Method of Analysis (Unsignalized Intersections) The HCM unsignalized methodology for stop-controlled intersections was utilized for the analysis of the unsignalized intersections. This methodology estimates the average control delay for each of the subject movements and determines the level of service for each movement. For all-way stop controlled intersections, the overall average control delay measured in seconds per vehicle, and level of service is then calculated for the entire intersection. For one-way and two-way stop-controlled (minor street stop-controlled) intersections, this methodology estimates the worst side street delay, measured in seconds per vehicle and determines the level of service for that approach. The HCM control delay value translates to a Level of Service (LOS) estimate, which is a relative measure of the intersection performance. The six qualitative categories of Level of Service have been defined along with the corresponding HCM control delay value range, as shown in Table 3-2. LINSCOTT, l.Aw&GREENSPAN, engineers 6 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N.14700\2�H7J7 - First Harbllr :\fix�d lJ;�. SantJ AnJ1R�1mrt147J7 Fust Harl>or ,\h>.�d-l'se, Salltn .\n,1 Tr:iffic Study W-23-23 00.: Exhibit C to Exhibit 1 TABLE 3-1 LEVEL OF SERVICE CRITERIA FOR SIGNALIZED INTERSECTIONS (ICU METHODOLOGY) Level of Service (LOS) B C E F LINSCOTT, LAW&GREENSPAN, engineers Intersection Capacity Utilization Value (V/C) ,;; 0.600 0.601 -0.700 0. 70 I -0.800 0.80 I -0.900 0.90 I -1.000 >1.000 7 Level of Service Description EXCELLENT. No vehicle waits longer than one red light, and no approach phase is fully used. VERY GOOD. An occasional approach phase is fully utilized; many drivers begin to feel somewhat restricted within groups of vehicles. GOOD. Occasionally drivers may have to wait through more than one red light; backups may develop behind turning vehicles. FAIR. Delays may be substantial during portions of the rush hours, but enough lower volume periods occur to permit clearing of developing lines, preventing excessive backups. POOR. Represents the most vehicles intersection approaches can accommodate; may be long lines of waiting vehicles through several signal cycles. FAILURE. Backups from nearby locations or on cross streets may restrict or prevent movement of vehicles out of the intersection approaches. Potentially very long delays with continuously increasing queue lengths. LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana K;,--1700\2234737 • Fim H.11bor :,.fi��d Use. S:mt:t Ana1R�port\�737 fil'st Harhor .\hwd-l 'se.. Santa .\n:t Troffic Study !0-23-23 doc Exhibit C to Exhibit 1 TABLE3-2 LEVEL OF SERVICE CRITERIA FOR UNSIGNALIZED INTERSECTIONS (HCM METHODOLOGY)' Level of Service Highway Capacity Manual (HCM) (LOS) Delay Per Vehicle (seconds/vehicle) Level of Service Description A s; 10.0 Little or no delay B >10.0ands; 15.0 Short traffic delays C >15.0 ands; 25.0 Average traffic delays D >25.0 ands; 35.0 Long traffic delays E >35.0 ands; 50.0 Very long traffic delays F >50.0 Severe congestion Source: Highway Capacity Manual 7'1' Edition, Chapter 20: Two-Way Stop-Controlled Intersections. The LOS criteria apply to each lane on a given approach and to each approach on the minor street. LOS is not calculated for major-street approaches or for the intersection as a whole. LINSCOTT, LAw&GREENSPAN, engineers 8 LLG Re[ 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit C to Exhibit 1 3.4.3 Level of Service Criteria According to the City of Santa Ana, LOS D is the minimum acceptable condition that should be maintained during the peak commute hours. However, the City of Santa Ana has defined exceptions to this criterion at specific locations within the study area. The City of Santa Ana has defined major development areas where LOS "E" is considered acceptable. Based on the above, the following summarizes the LOS required for each key study intersection: LOS "D" Requirements LOS "E" Requirements I.Harbor Boulevard at 5th Street 2.Harbor Boulevard at I st Street 3.5 Existing Level of Service Results Table 3-3 summarizes the existing peak hour service level calculations for the two (2) key study intersections based on existing traffic volumes and current street geometrics. Review of Table 3-3 indicates that all key study intersections currently operate at an acceptable level of service (LOS) during the AM and PM peak hours when compared to the LOS criteria defined in this report. Appendix B presents the ICU/LOS calculation worksheets for the two (2) key study intersections for the AM peak hour and PM peak hour. LINSCOTT, LAW & GREENSPAN, engineers 9 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit C to Exhibit 1 TABLE3-3 EXISTING PEAK HOUR INTERSECTION CAPACITY ANALYSIS Minimum Acceptable Control Time Key Intersection Jurisdiction LOS Type Period ICU LOS Harbor Boulevard at 80 Traffic AM 0.719 I. 5th Street Santa Ana D Signal PM 0.729 C Harbor Boulevard at 80 Traffic AM 0.760 2. Santa Ana E Signal I st Street PM 0.811 D Bold ICU values indicate adverse service levels based on the Cities LOS standards. LINSCOTT, LAW & GREENSPAN, enginee/S 10 LLG Ref 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Is ,.:17W122347l7 • F1m Rubor \h>.,:d Usi.:. S:mta Ana'RcporN7J7 f1r<1 Harl-or \lv,�-d-Use. Santa .\na Traffic Stud� 10-23-23 doc Exhibit C to Exhibit 1 4.0 TRAFFIC FORECASTS In order to estimate the traffic characteristics of the proposed Project, a multi-step process has been utilized. The first step is trip generation, which estimates the total arriving and departing traffic on a peak hour and daily basis. The traffic generation potential is forecast by applying the appropriate vehicle trip generation equations or rates to the Project development tabulation. The second step of the forecasting process is trip distribution, which identifies the origins and destinations of inbound and outbound Project traffic. These origins and destinations are typically based on demographics and existing/anticipated travel patterns in the study area. The third step is traffic assignment, which involves the allocation of Project traffic to study area streets and intersections. Traffic assignment is typically based on minimization of travel time, which may or may not involve the shortest route, depending on prevailing operating conditions and travel speeds. Traffic distribution patterns are indicated by general percentage orientation, while traffic assignment allocates specific volume forecasts to individual roadway links and intersection turning movements throughout the study area. With the forecasting process complete and Project traffic assigntiients developed, the effect of the proposed Project's added traffic is isolated by comparing operational (LOS) conditions at selected key intersections using expected future traffic volumes with and without forecast Project traffic. The need for site-specific and/or cumulative local area traffic improvements can then be evaluated. LINSCOTT, LAw&GREENSPAN, engineers 11 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit C to Exhibit 1 4.1 Project Traffic Generation Traffic generation is expressed in vehicle trip ends, defined as one-way vehicular movements, either entering or exiting the generating land use. Generation equations and/or rates used in the traffic forecasting procedure are found in the 11th Edition of Trip Generation, published by the Institute of Transportation Engineers (]TE) [Washington D.C., 2021]. The upper portion of Table 4-1 summarizes the trip generation rates used in forecasting the vehicular trips generated by the proposed Project. As shown in Table 4-1, !TE Land Use 221: Multifamily Housing Mid Rise and !TE Land Use 822: Strip Retail Plaza Less than 40K trip rates were used to forecast the trip generation potential of the proposed Project. The lower portion of Table 4-1 presents the project's forecast peak hour and daily traffic volumes, inclusive of applicable pass-by trip reductions. As shown on the bottom of Table 4-1, the proposed Project is forecast to generate approximately 1,575 daily trips, with I 00 trips (36 inbound, 64 outbound) produced in the AM peak hour and 131 trips (73 inbound, 58 outbound) produced in the PM peak hour on a "typical" weekday. Please note that trip generation for the proposed Project includes adjustments for pass-by as recommended by !TE. The pass-by reduction factors are based on a review of available information published in the 11th Edition of Trip Generation, published by the Institute of Transportation Engineers (!TE), [Washington, D.C., 2021]. 4.2 Project Traffic Distribution and Assignment Figure 4-1 presents the traffic distribution pattern for the proposed Project. Project traffic volumes both entering and exiting the project site have been distributed and assigned to the adjacent street system based on the following considerations: ■ location of site access points in relation to the surrounding street system, ■the site's proximity to major traffic carriers and regional access routes, ■ physical characteristics of the circulation system such as lane channelization and presence oftraffic signals that affect travel patterns, ■presence of traffic congestion in the surrounding vicinity, and•ingress/egress availability at the project site, as well as allowance of "U-turn" movements at5th Street and 1st Street. The anticipated AM and PM peak hour project traffic volumes associated with the proposed Project are presented in Figures 4-2 and 4-3, respectively. Figure 4-3 also presents the daily Project traffic volumes. The traffic volume assignments presented in Figures 4-2 and 4-3 reflect the traffic distribution characteristics shown in Figure 4-1 and the traffic generation forecast presented in Table 4-1. LINSCOTT, LAW & GREENSPAN, engineers 12 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana � -'700\:�34737 -f,rst H�rbor \1,,..,d l 'se. S:uttJ And'R�pon'47J7 Fir$! Harl"'r \h.>..:d-l'.�, S.111ta ;\n;1 Traffic Study l0-2J-2J.doc Exhibit C to Exhibit 1 TABLE4-1 PROJECT TRAFFIC GENERATION FORECAST' !TE Land Use Code I Daily AM Peak Hour PM Peak Hour Project Description 2-Way Enter Exit Total Enter Exit Total Generation Factors: •221: Multifamily Housing Mid Rise (TE/DU) •822: Strip Retail Plaza Less than 40K (TEffSF) Proupsed Pro[ect Generation Forecast: •Residential (183 DU) •Retail (15,182 SF) Pass-by (Daily: IO%, AM: I 0% PM: 40%)3 Retail Subtotal Total Project Trip Generation Notes: •TE/DU = Trip ends per dwelling unit•TEffSF = Trip ends per thousand square feet 4.54 23% 54.45 60% 831 16 827 22 -83 :6 744 20 1,575 36 77% 0.37 61% 39% 40% 2.36 50% 50% 52 68 43 28 14 36 50 50 :6 .:1 -20 -20 12 32 30 30 64 100 73 58 2 3 Source: Trip Generation, 11th Edition, Institute ofTransportation Engineers, (ITE) [Washington, D.C. (2021)}. Source: The /TE Trip Generation Manual does not contain pass-by infonnatioti for the ITE LU 822: Strip Retail Plaza Less than 40K. Therefore, the Daily, AM peak hour, and PM peak hour pass-by rates were conservatively assumed to be 10% (estimated) for Daily, 10% (estimated) for AM peak hour, and 40% for PM peak hour (consistent with ITE LU 821 pass-by rates). LINSCOTT, LAW & GREENSPAN, engineelS 13 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana 0.39 6.59 71 JOO -40 60 131 Exhibit C to Exhibit 1 � 5TH <)g◊. 1ST LINSCOTT LAW & GREENSPAN engineers �NO SCALE � 0 I') � 5ll:9 8 95,: flit j���� 01()01{) � n I )> :;o OJ 0 :;o ............... :!J G) C fT1 :;o 0 )> ::::::.fitN :f� [;-.............. I' ........ ·:::::::::::::.'- ST <)v ST KEY @ ,. STUDY INTERSECTION q-= INBOUND PERCENTAGE FIGURE 4-1 - = OUTBOUND PERCENTAGE PROJECT TRAFFIC rz:a = PROJECT s1TE n1sTRIBUTION PATTERN FIRST HARBOR MIXED-USE PROJECT, SANTA ANA 9 Exhibit C to Exhibit 1 LINSCOTT LAW & GREENSPAN engineerc. 5TH 1ST �O SCALE o:=o JI l... o--J o-2, \._ 0 -or2)�.( I )> ;;o CD 0 ;;o CD r KEY (XX)= PASS-BY TRIPS�ii = PROJECT SITE ST :::!:l 0 )> \ \ FIGURE 4-2 AM PEAK HOUR PROJECT TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA 9 Exhibit C to Exhibit 1 LINSCOTT LAW & GREENSPAN e11gineers 5TI-i 1ST �OSCALE N \._ 0ONO -oJ I I... ,4 ST o-' ill! o-4, C fT1 ;;o 0 )> I > ;;o ID 1� 0 ;;o ,,-r--,,,,,-�, ,, / ' / ' I � \ Vl I 00 \ I I \._ 29(9)J � 1 J I \ \ I ( I \ 9(aellt Io,:::-/\I 'co' I \ � ✓-...... / ' I/')< / - - _,, -_ _,, / ' -_(-.-. .'":"T.'":"T.'":"T.� [\--'" 7WY 1.'.'.'0WYT.' t-·.·.·.·.·.·.·.·.·:.·.·.·.·.� :·:·:·:·:·:·:·:·:·:·:·:·:·:·] ::::::-ow :s·� 1)--................. f' ....... ·:::::::::::::." ST ID § KEY Aa = DAILY TRAFFIC VOLUMES (XX)= PASS-BY TRIPS '\ \ >---r--' / §: ' I oo, \ , J I \ \ 20(3�1,l. I \ � I ' - / --_,, FIGURE 4-3 �:� = PROJECT SITE PM PEAK HOUR AND DAILY PROJECT TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA I .., Exhibit C to Exhibit 1 4.3 Existing Plus Project Traffic Volumes The Existing Plus Project traffic conditions have been generated based upon existing conditions and the estimated project traffic. These forecast traffic conditions have been prepared to assess the potential effects of the Project upon the circulation system as it currently exists per the requirements of the City. This traffic volume scenario and the related intersection capacity analyses will identify the roadway improvements necessary to offset the Project, if any. Figures 4-4 and 4-5 present projected AM and PM peak hour traffic volumes at the two (2) key study intersections and three (3) Project driveways with the addition of the trips generated by the proposed Project to existing traffic volumes, respectively. Figure 4-5 also presents the Existing Plus Project daily traffic volumes. 4.4 Year 2028 Cumulative Base 4.4.1 Ambient Traffic Growth Horizon year, background traffic growth estimates have been calculated using an ambient traffic growth factor. The ambient traffic growth factor is intended to include unknown and future related projects in the study area, as well as account for regular growth in traffic volumes due to the development of projects outside the study area. The future growth in traffic volumes has been calculated at one percent (1.0%) per year. Applied to the Year 2023 existing traffic volumes, this factor results in a 5.0% growth in existing volumes to the near-term horizon year 2028. 4.4.2 Cumulative Projects In order to make a realistic estimate of future on-street conditions prior to implementation of the proposed Project, the status of other known development projects (related projects) within a two mile radius of the proposed project has been researched at the City of Santa Ana, City of Garden Grove, City of Fountain Valley and City of Westminster. With this information, the potential circulation effects of the proposed Project can be evaluated within the context of the cumulative impact of all ongoing development. Based on our research during the scoping process, there are nine (9) related projects in the City of Santa Ana and one (1) related project in the City of Garden Grove that are being processed for approval or to be constructed and fully operational within a two-mile radius of the proposed project site. These ten (10) related projects have been included as part of the cumulative background setting. Table 4-2 provides a brief description for each of the ten (10) related projects. Figure 4-6 graphically illustrates the location of the ten (10) related projects. These related projects are expected to generate vehicular traffic, which may affect the operating conditions of the key study intersections. Table 4-3 summarizes the trip generation potential for all ten (10) related projects on a daily and peak hour basis for a typical weekday. As shown, the related projects are expected to generate 4,705 daily trips, with 245 trips (103 inbound, 142 outbound) anticipated during the AM peak hour and 287 trips (162 inbound, 125 outbound) produced during the PM peak hour. LINSCOTT, LAW & GREENSPAN, engineers 14 LLG Ref 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit C to Exhibit 1 LINSCOTT LAW & GREENSPAN engineers 5TH 1ST I I \ ,,.....-;r--, / � '\. N I \.._ 33 I.( "'--o,LO«>-- ) I l... 94---' 138- 78, \ I I \ �N I'-:---< ...._ \.._ 163 -92,-141 �l! .. <O - I ;o CD 0 '---l �_.,..,._.,..,._..,..,.:-=lrl [:I?"!!.!-:-:-��?-� --......_ / /N / ......... \.._ ,so< o,-..n I --N -533\I ) I l ,-216 I \ 149---' )!! / 835-\ 197, �:8�/ '-/ ...._ - _,, .............. :-:-:-:-:-:-:-:-:-:-:-:-:-:-] . ·::.·.·.·.·.·.·.·.·:.·.•j ::::::.ow{ :s·� .............. 1 . . .. . . . . .. . . . . .............. .. ........ / / / CD r s KEY fiil = PROJECT SITE ;o 0 l> -t �/ >' � ' ST ,,.....-,--......_/ 0� I ) I I \ o---' 1� \ /'-/ ...._ '\. \ \ '\. \ I )J I N I/ L.. _,, ST )..- - r-- ......_ / " 0� \ I I ) I I \ o---' 11 I 22, .og \ I ' / ...._ L.. _,, FIGURE 4-4 EXISTING PLUS PROJECT AM PEAK HOUR TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA "' N � I N I � ;. ,;; ;; I :!. ...."' .... •,.;; 0 e 0 � ii : � 'll i � 0 � I ....• ....• e Exhibit C to Exhibit 1 LINSCOTT LAW & GREENSPAN engineers 5TH 1ST I I \ ,,,,.-r-' / � '\. N I \.._ 3J t r Olt'l ..,._"' <ON- ) I l gg-J 146-82, \ I I 00> \ <ON I N - < '--- _,,. '-....( / / / �-.--, / /:2�� \.._ 191 I --N -668\I ) j l r 227 \ \ 158_./ ),1.( I \ 879-���/20� / '--.... _,,. \.._ 171 -97, 110 ��f N :c )> ;:o CD 0 ;:o �_..,..,._..,..,._.,...._� [:��-!-:-:-:��-:�-� .............. :-:-:-:-:-:-:-:-:-:-:-:-:-:-] ···········:4·· .............. -:-:-:-:-:-:��:-}::: .. . . . . . . .. . ... • •:• ·:· ·:··:.'I CD r s KEY :!! C) C fTI ;:o 0 )> t� Vl -t '\,--/ ., � ' ST ,,,,.-/ 0� I ) l I o-' \ 1� \ /'-/ - '- '\ \ .--, '\. \ \ 'I t I ,..,00 N I / .__,,- ST ).--,.._' / o::S '\. I \ I ) I \ o-' 1 t I \ 22, "',';i \ I '-/ -- _,,. �OSCALE � = DAILY TRAmc VOLUMES [fil:::/J -PROJECT SITE FIGURE 4-5 EXISTING PLUS PROJECT PM PEAK HOUR AND DAILY TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA i 2 a. j ..., N 0 N I ..., N I :;! ;;; : ,;; 9 "' I :!: ......,...•�• g 0 � a:i2 E � _g i?"' I ...•..., • ,('. C Exhibit C to Exhibit 1 TABLE4·2 LOCATION AND DESCRIPTION OF CUMULATIVE PROJECTS' No. Cumulative Project City of Santa Ana I.Habitat for Humanity 2.Westview Housing 3.Haphan Residential Development 4.Bewley Street Townhomes 5. 5th and Harbor Mixed-UseDevelopment 6. Bella Terra Residential Community and Temple 7. Mountain View 8-Unit Condominium Development 8.Coptic Orthodox Church Euclid-Hazard ?-Eleven Service9. Station City o(Garden Grove 10.Harbor Place Pad Building Notes: SF= Square-feet DU = Dwelling units VFP = Vehicle Fueling Positions Location/Address 1921 West Washington Avenue 2534 West Westminster Avenue 3025 West Edinger Avenue 1122 North Bewley Street 419-421 North Harbor Boulevard 4006,4010, aud 4018 West Hazard Avenue 301 and 305 North Mountain View Street 4405 West Edinger Avenue 813 North Euclid Street 13200-13220 Harbor Boulevard 4 Source: City of Santa Ana and City of Garden Grove Planning Departments. LINSCOTT, LAw&GREENSPAN, engineers 15 Description 6 DU Affordable Housing 85 DU Multi-family Residential 18 DU Multi-family Residential 10 DU Condominium 94 DU Multi-family Residential 9,500 SF Retail 13 DU Single-family Residential 3,500 SF Temple 8 DU Condominium 110 Seat Expansion for Church 8VFP 3,045 SF Convenience Store 2,800 SF Fast Food Restaurant with Drive-thru 1,200 SF Restaurant LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit C to Exhibit 1 KEY 1. HABITAT FOR HUMANITY 2. WESTVIEW HOUSING 3. HAPHAN RESIDENTIAL DEVELOPMENT 4. BEWLEY STREET TOWNHOMES 5. 5TH AND HARBOR MIXED-USE DEVELOPMENT 6. BELLA TERRA RESIDENTIAL COMMUNITY AND TEMPLE 7. MOUNTAIN VIEW 8-UNIT CONDOMINIUMS DEVELOPMENT 8. COPTIC ORTHODOX CHURCH 9. EUCLID-HARARD 7-ELEVEN SERVICE STATION 10. HARBOR PLACE PAD BUILDING Garden Grove' f J i I KEY (j) CUMULATIVE PROJECT LOCATION E\] -PROJECT SITE FIGURE 4-6 LOCATION OF CUMULATIVE PROJECTS FIRST HARBOR MIXED-USE PROJECT, SANTA ANA Exhibit C to Exhibit 1 TABLE4-3 CUMULATIVE PROJECTS TRAFFIC GENERATION FORECAST' Daily AM Peak Hour PM Peak Hour Cumulative Project Description 2-Way In Out Total In Out Total l.Habitat for Humanity 40 0 2 2 2 I 2.Westview Housing 573 8 26 34 27 16 3.Haphan Residential Development 121 2 5 7 6 3 4.Bewley Street Townhomes 67 I 3 4 3 2 5.5th and Harbor Mixed-Use Development 1,099 21 37 58 49 37 6. Bella Terra Residential Community and Temple 115 2 4 6 5 4 7.Mountain View 8-Unit CondominiumDevelopment 54 I 2 3 3 I 8.Coptic Orthodox Church 99 5 3 8 5 6 9.Euclid-Hazard ?-Eleven Service Station 1,426 , 25 25 50 33 32 10.Harbor Place Pad Building 1,111 38 35 73 29 23 Cumulative Projects 4,705 103 Total Trip Generation Potential 142 245 162 125 s Unless otherwise noted, Source: Trip Generation, 1 l1h Edition, Institute of Transportation Engineers (ITE), Washington, D.C. (2021). LINSCOTT, LAW & GREENSPAN, engineers 16 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana 3 43 9 5 86 9 4 11 65 52 287 Exhibit C to Exhibit 1 The AM and PM peak hour traffic volumes associated with the ten (I 0) related projects in the Year 2028 are presented in Figures 4-7 and 4-8, respectively. Figure 4-8 also presents the daily related project traffic volumes. 4.4.3 Year 2028 Cumulative Base Traffic Volumes Figures 4-9 and 4-10 present the AM and PM peak hour cumulative base traffic volumes ( existing traffic + ambient growth + cumulative projects) at the two (2) key study intersections for the Year 2028, respectively. 4.4.4 Year 2028 Cumulative Plus Project Traffic Volumes Figures 4-11 and 4-12 illustrate the Year 2028 forecast AM and PM peak hour traffic volumes, with the inclusion of the trips generated by the proposed Project, respectively. LINSCOTT, LAW&GREENSPAN, engineers 17 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N ,-J700\12H7J7 -Ftr�t H:ubor Mi�"J L-se. S:mta AJ1a'Rc1)011·-HJ7 fm,t Harbor �fixed-Use. Santa .\na Traffic Study lfJ-23-23.doc Exhibit C to Exhibit 1 LINSCOTT LAW & GREENSPAN engineer, 5TH 1ST �O SCALE OO>CO Jll.... o-' 1-°' \__ 0 -or 22:)J[ I ► ;o (D 0 ;o r.':. ·::. ·::. ·::: • ::'1 t ............. -�.............. . . . . . . . .. . . .. . � .............. 1. . . . . . . .. . . . . . .............. -:-:-:-:-:-:-:-:-:-:-:-:-:-:1 :-:-:-:-:-:-:-:-:-:-:-:-:-:-] KEY fE:)� = PROJECT SITE 0 ► (/) --i ST ST FIGURE 4-7 AM PEAK HOUR CUMULATIVE PROJECT TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA I .., N I 9 "' • I � Exhibit C to Exhibit 1 LINSCOTT LAW & GREENSPAN engi11een 5TH 1ST �OSCALE CCX>� \.._ 0 ) � l,. -or 22o---' �.LC 2- � :r: CD 0 ;:o KEY ...BJ2!L • OAJLY TRAFFIC VOLUMES �� = PROJECT SITE :!l fTI ;:o 0 )> lo (/) -i ST ST FIGURE 4-8 PM PEAK HOUR AND DAILY CUMULATIVE PROJECT TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA N I I 0 9 Exhibit C to Exhibit 1 LINSCOTT LAW & GREENSPAN engineen 5TH 1ST �O SCALE �g;in(ON� Jil 99---' 146-BO-\ \._ 171 -97 r 1ss �if r )> w 0 ;:o r.·::.·::.·::.·:::i-:-:-:-:-:-:-:-:-:-:-:-:-:-:� :-:-:-:-:-:-:-:-:-:-:-:-:-:-] -:-:-:-:-:-:-:-:-:-:-:-:-:-:1 :-:-:-:-:-:-:-:-:-:-:-:-:-:-] w s KEY filll = PROJECT SITE )> (/) -t ST ST FIGURE 4-9 YEAR 2028 AM PEAK HOUR CUMULATIVE BASE TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA I .... N I 0 ;. 00 9 Exhibit C to Exhibit 1 LINSCOTT LAW & GREENSPAN e11gi11eers 51H 1ST �OSCALE :3in <D•r--co�� J I \.. 58-' 139-68, \._ 282 -222r 142)Ir a,�� I )> ;u CD 0 ;u f::::::::::::::J [·:-:-:-:-:-:-:-:-:-:-:-:-:-:�:-:-:-:-:-:-:-:-:-:-:-:-:-:-]-:-:-:-:-:-:-:-:-:-:-:-:-:-:1:-:-:-:-:-:-:-:-:-:-:-:-:-:-] • ·:,:,.:_: ••••••• ·.1 CD KEY � = DAILY TRAFFIC VOLUMES Elful = PROJECT SITE 0 )> 1, (/) --l ST ST FIGURE 4-10 YEAR 2028 PM PEAK HOUR AND DAILY CUMULATIVE BASE TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA I ,,,NI Exhibit C to Exhibit 1 LINSCOTT LAW & GREENSPAN engineers 5TH 1ST �O SCALE ,., ..,.oin \.._ 171 r.oN� -97Jll r 110 ST gg-J �.i.( 146-in -"' 82, N "Tl G) C ITI :;:o 0 )> ::i:: )> :;:o CD 0 _:;:o ............... ::::::.ow{ :f.,'..:j 1)---.. •:•:<-:·:•:·:·:·:·:·:·:·:·:" ', ... """"""'-" ST KEY �� = PROJECT SITE FIGURE 4-11 YEAR 2028 AM PEAK HOUR CUMULATIVE PLUS PROJECT TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA ..,� I ..,N I 0 Exhibit C to Exhibit 1 LINSCOTT LAW & GREENSPAN engineers 5TH 1ST �OSCALE IO '---282:g�� ---222Jll r 146 58_) �1!139-n, -�� I > ;:o Ill 0 ;:o Ill � KEY ...!!a1Q!L = DAILY TRAFFIC VOLUMES �❖:m = PROJECT SITE ST ::!l "' C fTl ;o 0 > ti \ \ FIGURE 4-12 YEAR 2028 PM PEAK HOUR AND DAILY CUMULATIVE PLUS PROJECT TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA I .., N I 0 ,._ .., ,._ I .. :, Exhibit C to Exhibit 1 5.0 NON-CEQA TRAFFIC ANALYSIS The relative effect of the proposed Project during the AM peak hour and PM peak hour was evaluated based on analysis of future operating conditions at the two (2) key study intersections, without, then with, the proposed Project. The previously discussed capacity analysis procedures were utilized to investigate the future volume-to-capacity relationships and LOS characteristics at each study intersection. The potential effect of the Project at each key intersection was then evaluated using LOS standards and thresholds summarized below. 5.1 LOS Standards and Thresholds 5.1.1 City of Santa Ana Based on the City of Santa Ana, the need for potential improvements will be assessed based on the following criteria: ■ Project traffic would cause an intersection currently operating at an acceptable peak hour Levelof Service (LOS) to operate at an unacceptable peak hour LOS. The City of Santa Ana considersLOS D to be the minimum acceptable LOS for all intersections, or •The project increases traffic demand by 1% of capacity (ICU increase� 0.01) if the intersectionalready operates at an unacceptable LOS. ■At unsignalized intersections, the project causes an intersection at LOS D or better to degrade toLOS EorF. 5.2 Traffic Analysis Scenarios The following scenarios are those for which volume/capacity calculations have been performed at the five (5) key intersections for existing plus project and near-term (Year 2028) traffic conditions: A.Existing Traffic Conditions; B.Existing Plus Project Traffic Conditions; C.Scenario (B) with Improvements, if necessary; D.Near-Term (Year 2028) Cumulative Traffic Conditions, E.Near-Term (Year 2028) Cumulative plus Project Traffic Conditions; F.Scenario (E) with Project-Related Mitigation, if necessary. LINSCOTT, LAW & GREENSPAN, engineers 18 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N ,-1700·213�737 -F,rsl Ha,bor �h��d t.::�e. S:tnt:t Ana'Rt1lort'47J7 Fust HaJ l'Or M,��d-l'�. Sa.iu:i .\n:t Traffic Stud) 10-2J-23.doc Exhibit C to Exhibit 1 5.3 Existing (2023) Plus Project Traffic Conditions Table 5-1 summarizes the peak hour Level of Service results at the two (2) key study intersections for existing plus project traffic conditions. The first column (I) of ICU/LOS values in Table 8-1 presents a summary of existing AM and PM peak hour traffic conditions (which were also presented in Table 3-3). The second column (2) lists existing plus project traffic conditions. The third column (3)shows the increase in ICU value due to the added peak hour Project trips and indicates whether the traffic associated with the Project will exceed the LOS thresholds defined in this report. The project-specific intersection improvement described below has been presumed as part of the evaluation of Existing Plus Project traffic conditions: ■No. 2 -Harbor Boulevard at I st Street: Widen the westbound approach of the intersection to provide an exclusive westbound right-tum lane on !st Street with 190-feet of storage. Review of Column 3 of Table 5-1 indicates that the two (2) key study intersections are forecast to operate at LOS D or better during the weekday AM and PM peak hours with the addition of Project traffic to Existing traffic conditions. Review of Columns 2 and 3 of Table 5-1 indicates that the traffic associated with the proposed Project will not require improvements at either of the two (2) key study intersections, when compared to the LOS standards and thresholds specified in this report. Appendix B presents the existing plus project ICU/LOS calculations for the two (2) key study intersections. LINSCOTT, LAW & GREENSPAN, engineers 19 LLG Ref 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit C to Exhibit 1 TABLE 5-1 ExiSTING PLUS PROJECT PEAK HOUR INTERSECTION CAPACITY ANALYSIS e ;:a (I) (2) • s"'Existing Existing Plus Project .§ c.C .s tt ...l Traffic Conditions Traffic Conditions :,q Time Key Intenection Period ICUillCM LOS ICUillCM LOS Harbor Boulevard at AM 0.719 C 0.730 C I. 5th Street D PM 0.729 C 0.733 C Harbor Boulevard at AM 0.760 C 0.765 C 2. 1st Street6 E PM 0.811 D 0.789 C � Bold ICU values indicate adverse service levels based on the Cities LOS standards. 6 A 190-foot westbOW1d ri5ht-turn pocket at the intersection ofHatborBoulevard and I"' Street will be constructed as part of the proposed Proiect. LINSCOTT, LAW & GREENSPAN, engineers 20 (J) Exceeds LOS Thresholds Increase Y-o 0.011 No 0.004 No 0.005 No -0.022 No LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Pr(!ject, Santa Ana Exhibit C to Exhibit 1 5.4 Year 2028 Traffic Conditions Table 5-2 summarizes the peak hour Level of Service results at the two (2) key study intersections for the Year 2028 horizon year. The first column (I) of ICU/LOS values in Table 5-2 presents a summary of existing AM and PM peak hour traffic conditions. The second column (2) lists projected cumulative traffic conditions (existing plus ambient plus related projects traffic) based on existing intersection geometry, but without any traffic generated from the proposed Project. The third column (3) presents forecast Year 2028 near-term traffic conditions with the addition of Project traffic. The fourth column (4) shows the increase in ICU value due to the added peak hour Project trips and indicates whether the traffic associated with the Project will exceed the LOS thresholds defined in this report. The project-specific intersection improvement described below has been presumed as part of the evaluation of Year 2028 Cumulative Plus Project traffic conditions: •No. 2 -Harbor Boulevard at 1'1 Street: Widen the westbound approach of the intersection to provide an exclusive westbound right-tum lane on 1st Street with 190-feet of storage. 5.4.1 Year 2028 Cumulative Base Traffic Conditions Review of Column 2 of Table 5-2 indicates that the two (2) key study intersections are forecast to continue to operate at acceptable levels of service (LOS D or better) during the AM and PM peak hours for Year 2028 Cumulative Base traffic conditions. 5.4.2 Year 2028 Cumulative Plus Project Conditions Review of Column 3 of Table 5-2 indicates that the two (2) key study intersections are forecast to continue to operate at acceptable levels of service (LOS D or better) during the AM and PM peak hours with the addition of Project traffic to Year 2028 Cumulative traffic conditions. Review of Columns 3 and 4 of Table 5-2 indicates that the traffic associated with the proposed Project will not require improvements at either of the two (2) key study intersections, when compared to the LOS standards and thresholds specified in this report. Appendix B also presents the near-term ICU/LOS calculations for the two (2) key study intersections. LINSCOTT, LAW & GREENSPAN, engineers 21 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N' ,4700·.21J-1737. F1rs1 Harbor \!,xed l'�e. S:inta ,\na'R�l'O' 1 47J7 Fir�\ H:u l>or \h\�d-L:'<1!, S.uua Ana Tr:iffic Study 10-2J-1J <l<1c Exhibit C to Exhibit 1 TABLE5•2 YEAR 2028 PEAK HOUR INTERSECTION CAPACITY ANALYSIS 8 .. = a r,i (I) (2) .§ �s Existing Year 2028 .5 � Traffic Conditions Traffic Conditions :q Time Key Intersection Period ICU/HCM LOS ICUillCM LOS Harbor Boulevard at AM 0.719 C 0.770 C I. 5th Street D PM 0.729 C 0.781 C Harbor Boulevard at AM 0,760 C 0.801 D 2. 1'1 Street7 E PM 0.811 D 0.864 D � Bold ICU values indicate adverse service levels based on the Cities LOS standards 7 A westbound right-b.lm pocket at the intersection ofHarborBoulevard and l" Street will be constructed as part of the proposed Project. LINSCOTT, LAW &GREENSPAN, enginer;rs (J) Year2028 Plus Project (4) Traffic Conditions Ei:ceeds LOS Thresholds ICU/HCM LOS Increase Ye,JNo 0.781 C 0,011 No 0.791 C 0.010 No 0,805 D 0.004 No 0.837 D -0.027 No LLG Ref. 2-23-4737-1 Fi Ill Harbor Mixed-Use Project, Santa Ana Exhibit C to Exhibit 1 6.0 SITE ACCESS AND INTERNAL CIRCULATION EVALUATION 6.1 Site Access Access to the Project will be provided via one (!) right-turn in/out only driveway on Harbor Boulevard and two (2) driveways restricted to left-turns/right-turns in, and right-turns out, on Figueroa Street. Table 6-1 summarizes the intersection level of service results for the three (3) proposed Project driveways under Existing and near-term (Year 2028) traffic conditions at completion and full occupancy of the proposed Project based on the HCM methodology. As shown, these Project driveways are forecast to operate at LOS D or better during the AM peak hour and PM peak hour. As such, Project access would be adequate. Motorists entering and exiting the Project site would be able to do so without undue congestion. Furthermore, the anticipated queues at each of the Project driveways are anticipated to be no more than one (I) vehicle during the AM and PM peak hours. Appendix C presents the existing and near-term HCM/LOS calculations for the three (3) Project driveways. LINSCOTT, l.Aw&GREENSPAN, engineers 23 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project. Santa Ana N· ,--1700\nH7J7 • First Harbor :,.fi��d Use. S.mta Ana1R�po1t147J7 F1rs1 !-fa l>or �11��d-Usc. S:m1.,.1 .\na Traffic Stud,· \0-23-2J do,; Exhibit C to Exhibit 1 TABLE 6-1 PROJECT DRIVEWAY PEAK HOUR INTERSECTION CAPACITY ANALYSIS Key Intersection Harbor Boulevard at A. Project Driveway No. 1 B. Figueroa Street at Project Driveway No. 2 (North) Figueroa Street at C. Project Driveway No. 3 (South) Notes· •s/v = seconds per vehicle LINSCOTT, l.Aw & GREENSPAN, engineers Intersection Time Control Period One-Way AM Stop PM One-Way AM Stop PM One-Way AM Stop PM 24 (I) (2) Existing Year2028 Plus Project Plus Project Traffic Conditions Traffic Conditions HCM LOS HCM LOS 15.4 s/v C 16.1 s/v 24.6 s/v C 27.1 s/v D 8.4 s/v A 8.4 s/v A 8.5 s/v A 8.5 s/v A 8.5 s/v A 8.5 s/v 8.6 s/v A 8.6 s/v A LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N A70(i22JHJ7 -F,m Harbor M,,.ed t:w, Sant� A11a'R�po11'4737 F11�11-for!,or M,x�d-USI!, SanL1 .\na Traffic Stud�· 1◊-2J-2�.doc Exhibit C to Exhibit 1 6.1.1 Traffic Gap Assessment To supplement the level of service analysis, a traffic gap analysis was conducted along Harbor Boulevard, as well as at the intersection of Figueroa Street at I'' Street, to determine if the existing traffic gaps along the main arterial roadways are considered adequate to accommodate egress at the proposed Project driveways. For the purposes of this study, it is assumed that the minimum time for one vehicle to complete the outbound right-tum movement and outbound left-tum movement is 7 seconds and IO seconds, respectively. These duration criteria were derived from empirical data collected by LLG from prior studies, and are considered conservative when compared against Table 405. IA of the Caltrans Highway Design Manual, which indicates a minimum of 6.5 seconds is required for a passenger vehicle to complete a right-tum from a stop, and a minimum of 8.5 seconds is required for a passenger vehicle to complete a left-tum from a stop when crossing three lanes. Table 6-2 presents a summary of the results from traffic gap observations/surveys performed in September 2023 for the westbound right-tum movement at the intersection of Harbor Boulevard at Project Driveway No. I, and the southbound right-tum movement at the intersection of Figueroa Street at I st Street. Table 6-2 indicates that based on the gap surveys, traffic gaps along northbound Harbor Boulevard and on westbound !st Street (that meet the duration criteria described previously) were observed to occur more frequently compared to the number of times a vehicle would be exiting the Project site using the driveway off Harbor Boulevard, or a vehicle exited/would be exiting from southbound Figueroa Street, to enter into/merge with the traffic stream already on Harbor Boulevard and I st Street. Based on these empirical results, it is reasonable to conclude that there would be an adequate number of available gaps in traffic to accommodate right-turning vehicles from the Project site onto Harbor Boulevard, and from southbound Figueroa Street onto westbound I st Street. Table 6-3 summarizes the results of the traffic gap analysis for the southbound left-tum movement at the intersection of Figueroa Street at 1st Street. Table 6-3 indicates that based on the gap surveys, traffic gaps along !st Street (that meet the duration criteria described previously) were observed to occur more frequently compared to the number of times a vehicle exited/would be exiting from southbound Figueroa Street to enter into/merge with the traffic stream already on I st Street. Based on these empirical results, it is reasonable to conclude that there would be an adequate number of available gaps in traffic to accommodate left-turning vehicles from southbound Figueroa Street onto eastbound I st Street. As described previously, Project-specific improvements are planned for implementation at the intersection of Harbor Boulevard and !st Street (Intersection No. 2) that were previously approved by the City. As part of those improvements, the Project will be adding a right-tum pocket (with a total length of 213 feet, comprised of 186 feet of storage length, and 27 feet of transition length) along I st Street on the westbound approach of the intersection. The additional roadway capacity on westbound 1st Street due to the provision of the future right-tum pocket could help increase the number of available traffic gaps that would facilitate southbound right-turns from Figueroa Street onto I st Street. LINSCOTT, LAW & GREENSPAN, engineers 25 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit C to Exhibit 1 TABLE 6-2 RIGHT• TURN Our VEHICLE GAP ANALYSIS Harbor Boulevard at Project Driveway No. 1 (Westbound Right-Turn) Figueroa Street at P1 Street(Southbound Right-Tum) AM Peak Hour (7AM-8AM) PM Peak Hour (SPM-6PM) AM Peak Hour (7AM -8Al\[) PM Peak Hour (5PM-6PM) Gaps Total Gaps Total Gaps Total Gaps Total Vehicles Occurring Vehicles Vehicles Occurring Vehicles Vehicles Occurring Vehicles Vehicles Occurring Vehicles Served During that could Served During that could Served During that could Served During that could Gap8 by Peak b, by .... b, by .... b, by . ... b, (seconds) Gap9 Hour!U Served11 Gap9 Hour10 Served11 Gap9 Hour10 Served11 Gap9 Hour10 Served11 " " " 7-13 I 59 59 I 45 45 I 52 52 I 17 17 14-20 2 21 42 2 24 48 2 19 38 2 9 18 21-27 3 7 21 3 16 48 3 12 36 3 I 3 :::2s 4 20 80 4 9 36 4 17 68 4 3 12 Total Vehicles that Total Vehicles that Total Vehicles that Total Vehicles that could be 202 could be 177 could be 194 could be so Accommodated by Accommodated by Accommodated by Accommodated by Traffic Gaps Traffic Gaps Traffic Gaps Traffic Gaps Total Vehicles Exiting Total Vehicles E:s:iting Total Vehicles Exiting Total Vehicles Exiting the Project11 33 the Project11 38 the Project & Figueroa 49 the Project & Figueroa 43 Streetn Street11 Adequate Traffic Yo, Adequate Traffic y., Adequate Traffic Yo, Adequate Traffic y., Gaps? Gaps? Gaps? Gaps? A gap is defined as the time interval between cars crossing the Projectdriveway/minorstreet. For puiposes of this study, it is assumed the minimum time for one vehicle to complete a turning movement out of the Project driveway is 7 seconds, which was derived from empirical data collected by LLG. Per Ta hie ./OS.IA of the Caltrans Highway Design Manual, a minimum of6.5 seconds is required for a passenger vehicle to complete a right-tum from a stop, so an assumption of7 seconds is considered conservative. Values are based on gap survey performed on Wednesday September 27, 2023. Total Vehicles that could be Served= (Number of Vehicles Served) x (Number of Gaps During Peak Hour) Total vehicles exiting is based on Year 2028 Plus Project traffic conditions traffic volumes, Although Figueroa al I" Street is not a study intersection, ex:isting counts were collected at the intersection for the purposes of this gap analysis. LINSCOTT, LAW & GREENSPAN, engineer.. ' LLG Ref. 2-23-4737-1 26 First Harbor Mixed•Use Project, Santa Ana Exhibit C to Exhibit 1 13 14 IS 16 17 TABLE6-3 LEFT. TURN Our VEHICLE GAP ANALYSIS Figueroa Street at !51 Street (Southbound Left�Turn) AM Peak Hour (7 AM -8AM) PM Peak Hour (5PM-6PM) Gaps Total Gaps Total Vehicles Occurring Vehicles Vehicles Occurring Vehicles Served During that Served During that Gap13 by Peak could be by Peak could be (seconds) Gap14 Hour15 Served16 Gapt4 Hour15 Served16 10-19 I 47 47 I 15 15 20-29 2 16 32 2 6 12 30-39 3 7 21 3 2 6 2: 40 4 4 16 4 0 0 Total Vehicles that Total Vehicles that could be 116 could be 33 Accommodated by Accommodated by Traffic Gaps Traffic Gaps Total Vehicles Exiting Total Vehicles Exiting the Project & Figueroa 28 the Project & Figueroa 20 Street17 Street17 Adequate Traffic Yes Adequate Traffic Yes Gaps? Gaps? A gap is defined as the time interval bet\Veen cars crossing the Project driveway/minor street. For purposes of this study, it is assumed the minimum time for one vehicle to complete a turning movement out of the Project driveway is 10 seconds, which was derived from empirical data collected by LLG. Per Table 405.JA of the Caltrans Highway Design Manual, a minimum of 8.5 seconds is required for a passenger vehicle to complete a left•tum from a stop when crossing three lanes, so an assumption of IO seconds is considered conseivative. Values are based on gap suivey perfonned on Wednesday September 27, 2023. Total Vehicles that could be Seived = (Number of Vehicles Seived) x (Number of Gaps During Peak Hour) Total vehicles exiting is based on Year 2028 Plus Project traffic conditions traffic volumes. Although Figueroa at I st Street is not a study intersection, existing counts were collected at the intersection for the purposes of this gap analysis. LINSCOTT, LAw& GREENSPAN, engineers 27 LLG Re£ 2-23-4737-1 First Harbor Mixed.Use Project, Santa Ana N. 1�700\11H737 -first H:ubor 1'-li��d l!�. S:mta ,\na\R�po1t'-17J7 Fust Haibor ;I.I1��d-U� Sai1L1 ,\n� Traffic StuJy 10-23-23 doc Exhibit C to Exhibit 1 6.2 Internal Circulation Evaluation Based on our review of the preliminary site plan, driveway lengths are sufficient such that access to parking spaces would not be impeded by internal vehicle queuing/stacking. Curb return radii have been confirmed and are adequate for service/delivery trucks and trash trucks. The circulation on each level of the parking structure is adequate, with sufficient sight distance along the drive aisles. 6.3 Sight Distance Evaluation At intersections and/or Project driveways, a substantially clear line of sight should be maintained between the driver of a vehicle waiting at the crossroad and the driver of an approaching vehicle. Adequate time must be provided for the waiting vehicle to either cross all lanes of through traffic, cross the nearby lanes and turn left, or turn right, without requiring through traffic to radically alter their speed. A sight distance evaluation has been performed for the three (3) Project driveways located along Harbor Boulevard and Figueroa Street, as well as the intersection of Figueroa Street and I st Street. The Sight Distance Evaluation prepared for the Project driveways is based on the criteria and procedures set forth by the California Department of Transportation (Caltrans) in the State's Highway Design Manual (HDM). Corner sight distance was utilized for the evaluation. Corner sight distance is defined in the Caltrans HDM to be the distance required by the driver of a vehicle, traveling at a given speed, to maneuver their vehicle and avoid an object without radically altering their speed. Line of sight for corner sight distance is to be determined from a 3 ½ foot height at the location of the driver of a vehicle on a minor road to a 4¼ foot object height in the center of the approaching lane of the major road. Based on the criteria set forth in Table 405.IA of the Caltrans HDM and a posted speed limit of 40 mph on Harbor Boulevard, a corner sight distance of 382 feet for right-turning vehicles is required for Project Driveway I. Based on the criteria set forth in Table 405.IA of the Caltrans HDM and a prima facie speed limit of 25 mph on Figueroa Street, a corner sight distance of239 feet is required for right-turning vehicles at Project Driveways 2 and 3. Based on the criteria set forth in Table 405.IA of the Caltrans HDM and a prima facie speed limit of 40 mph on 1 st Street, a corner sight distance of 382 feet is required for right-turning vehicles. For left-turning vehicles, a corner sight distance of 434 feet is required when looking to the left and 492 feet is required when looking to the right. Figure 6-1 presents the results of the sight distance evaluation for right-turning vehicles at Project Driveway I based on the application of the corner sight distance criteria. The figure illustrates the limited use areas. As shown, the sight lines at the proposed Project driveway are expected to be adequate as long as obstructions within the sight triangles are minimized. LINSCOTT, lAW & GREENSPAN, engineers 28 LLG Re( 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N' ,4700\2234737 -Fir�t lfarbor i\f1x�d u�e. Sant� ,\na' Repo,11�737 Fii�t l!arbm �li,.�d-Use, Sn11t.1 .\n;t Trnfiic St11dy l0-2J-2J.doc Exhibit C to Exhibit 1 Figure 6-2 presents the results of the sight distance evaluation for right-turning vehicles at Project Driveways 2 and 3 based on the application of the comer sight distance criteria. The figure illustrates the limited use areas. As shown, the sight lines at the two (2) Project driveways will be obstructed by vehicles parked on-street along Figueroa Street. Based on this, it is recommended to restrict on street parking along the segment of Figueroa Street adjoining the Project site to help facilitate traffic flows, and enhance visibility for southbound traffic on Figueroa Street and Project traffic exiting the driveways. Figures 6-3 and 6-4 present the results of the sight distance evaluation for southbound right-turning vehicles and southbound left-turning vehicles, respectively, at the intersection of Figueroa Street and 1st Street based on the application of the comer sight distance criteria. The figure illustrates the limited use areas. As shown, the sight lines for southbound right-turning and left-turning vehicles on Figueroa Street are expected to be adequate as long as obstructions within the sight triangles are minimized. LINSCOTT, LAW & GREENSPAN, engineers 29 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N A700,22J.l7J7 • Fn$1 Ha,bor \hxcd l'.Si!. Sanu -\na'R1lpo,t'H37 F1f51 Harl-or .\11).cd-\;S<e. Sant.1 .\na Tmffic Study I0-13-2J.doc Exhibit C to Exhibit 1 SIGHT DISTANCE DESIGN SPEED LIMIT: REQUIRED CORNER SIGHT DISTANCE: 40 MPH 382 FEET -., LEGEND � PUBUC RJCHT-OF-WAY I.hi/TIT) US£ ARCA· TO £NSl/l?E AD£0UATE SIGHT OISTANC£, fW?OSCAP£ ANO/OR IANOSCA/'£ SH'J.L NOT 8£ HICHER THAN JO INCHES ABO\£ TH£ CUR8/SIO€WALJ(, NO ITNC£S OR WALLS IN UMITElJ use AR£A II I f -r:;-t �, .. 1--, --'--+---u SOURCE: PRIMIOR FIGURE 6-1 HARBOR BOULEVARD SIGHT DISTANCE ANALYSIS FIRST HARBOR MIXED-USE PROJECT, SANTA ANA f Exhibit C to Exhibit 1 I� �O SCALE SIGHT DISTANCE DESIGN SPEED LIMIT: REQUIRED CORNER SIGHT DISTANCE: 25 MPH 239 FEET LEGEND � PU8UC RIGHT-OF-WA< LJMITll) US£ AR£:A: TO £NS/JR£ AIJCOllATC S/CHT DISTANCE, HAROSCAP£ ANO/OR lANOSCAff SH<l.L NOT 8£ HIGHER f>IAN JO INCH£:S ABO>!' TH£ C/JR8/SIOCWALX. NO F£:NC£:S OR WALLS IN UAIITCO /JS£ ARDl SOURCE: PRIMIOR FIGURE 6-2 FIGUEROA STREET SIGHT DISTANCE ANALYSIS FIRST HARBOR MIXED-USE PROJECT. SANTA ANA Exhibit C to Exhibit 1 SIGHT DISTANCE DESIGN SPEED UMIT: REQUIRED CORNER SIGHT DISTANCE LOOKING LETT: 40 MPH 382 FEET LEGEND � PUBUC RIGHT-OF-WAY L/1,i/TITJ US£ ARE:A.· ro ENSURE A/)£OIJA TE S!CHT OISWICC. HAROSCAPE: ANO/OR I.ANOSCAPE: SH,ILL I/OT BE: HICHE:R THAN JO INCHES ABO\£ THE CUR8/SJOEWALX. NO FENCES OR WALLS IN LIMITE:0 USE: AR£A. SOURCE: PRIMIOR FIGURE 6-3 FIGUEROA STREET AT 1ST STREET SOUTHBOUND RIGHT SIGHT DISTANCE ANALYSIS FIRST HARBOR MIXED-USE PROJECT, SANTA ANA f Exhibit C to Exhibit 1 SIGHT DISTANCE 0£SIGN SPEED Ut,UT: REQUIRED CORNER SIGHT DISTANCE L()()l(ING LEn: REQUIRED CORNER SIGHT DISTANCE LOOKING RIGHT: -J�] rt· pn .. .r;.+:;-: . -';.. : ...., ... � � . . ' . -�fl11UWI • • ' J I • 40 MPH 434 FEET 492 FEET LEGEND t7222l �'#ff �11�-�olf:1/°s,::f OISTANCC. HAROSCAP£ ANO/OR LA/VOS� 51{4LL NOT 8£ HICH£R THAN JO INCHES ABO>£ TH£ CIJRB/SIOEWAJ.J(. NO Ff:NC£S OR WALLS IN UMrTEO /JS£ AREA SOURCE: PRIMIOR FIGURE 6-4 FIGUEROA STREET AT 1ST STREET SOUTHBOUND LEFT SIGHT DISTANCE ANALYSIS FIRST HARBOR MIXED-USE PROJECT, SANTA ANA Exhibit C to Exhibit 1 7 .0 INTERSECTION TURN POCKET QUEUING ANALYSIS To validate the adequacy of stacking provided for the northbound left-turn/"U-turn" lane located at the intersection of Harbor Boulevard and 5th Street, as well as the southbound left-turn/"U-turn" lane, westbound dual left-turn lanes, and future Project-specific improvement of a westbound right turn lane located at the intersection of Harbor Boulevard and I st Street, a queuing evaluation was conducted under Existing, Existing plus Project, Year 2028 Cumulative Base and Year 2028 Cumulative plus Project traffic conditions. The Highway Capacity Manual 6th Edition (HCM 6) methodology was utilized to confirm the adequacy of vehicular stacking for the aforementioned turn lanes located at the intersections of Harbor Boulevard and 5th Street, and Harbor Boulevard and I st Street. Tables 7-1 and 7-2 present the queueing results. Existing Plus Project and Year 2028 Plus Project traffic conditions presume the Project-specific improvement (i.e., addition of an exclusive right-turn pocket on the westbound approach) at the intersection of Harbor Boulevard and I st Street. Tables 7-1 and 7-2 indicate that adequate queue storage length is currently provided for the northbound left-turn/"U-turn" lane located at the intersection of Harbor Boulevard and 5th Street based on the anticipated maximum 95th percentile queue length under Existing, Existing plus Project, Year 2028 Cumulative Base, and Year 2028 Cumulative plus Project traffic conditions. Although the existing and future 95th percentile queues reported for the southbound left-turn/"U turn" and westbound left-turn movements at the intersection of Harbor Boulevard and I st Street exceed the existing storage lengths for the respective movements, these are existing queue storage deficiencies not caused by the Project. The 95th percentile queue lengths are conservative estimates of potential queues because, given 30 signal cycles per hour (based on a cycle length of 120 seconds), the 95th percentile queue might form in only 1.5 cycles during the peak hour. It should be noted further that the Project-generated traffic that could be added to the southbound and westbound left-turn movements are nominal (i.e., southbound left-turn: 15 AM peak hour trips, 36 PM peak hour trips; westbound left-turn: 11 AM peak hour trips, 16 PM peak hour trips), corresponding to a maximum of one vehicle on a given cycle. Tables 7-1 and 7-2 indicate that adequate queue storage length would be provided for the planned westbound right-turn pocket at the intersection of Harbor Boulevard and J st Street based on the anticipated maximum 95th percentile queue length under Existing plus Project, and Year 2028 Cumulative plus Project (during the AM peak hour only) traffic conditions. Although the future 95th percentile queue length of 232 feet during the PM peak hour would exceed the proposed pocket length of 213 feet, there is an additional 27 feet of queue storage on westbound I'' Street between the end of the future right-turn pocket and Figueroa Street that would result in a total storage length of240 feet, which could accommodate the forecasted queue length of232 feet. LINSCOTT, LAw&GREENSPAN, engineers 30 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit C to Exhibit 1 Based on the considerations above, improvements are not recommended. Appendix D provides the queuing calculation worksheets for Harbor Boulevard at 5th Street and Harbor Boulevard at I st Street. LINSCOTT, LAW & GREENSPAN, engineers 31 LLG Re[ 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana :-; 47U0\223--17J7 -First fl1rbor .\.�;,.ed l'se. S:rnta Ana'Report'4737 F,,;1 Harlxir :\10,.:d-Use, Santa ,\na TrJ!fo; Stud) I 0-23-23 dDc Exhibit C to Exhibit 1 Key Intersections I. Harbor Boulevard at 5th Street Northbound Left-Tumf'U-tum" 2. Harbor Boulevard at 1•tstreet Southbound Left-Tumf'U-tum" Westbound Dual Left-Tum Future Westbound Right-Turn20 18 Source_: Google Earth. Storage Provided 18 (ft) 185" 245" 3IO' 213•21 TABLE 7-1 EXISTING PLUS PROJECT QUEUING ANALYSIS (I) Existing Traffic Conditions AM Peak Hour PM Peak Hour Max, Adequate Max. Adequate Queue19 Storage Queue19 Storage (ft.) Yes/No (ft.) Yes/No 43' Yes 113' Yes 293' No 410' No 296' Yes 332' No ------- 19 Maximum queue in feet (ft) is calculated by taking the 95"' Percentile Queue length (ft) in HCM 7. A westbound right-tum pocket at the intersection ofHaroorBoulevard and I" Street will be constructed as part of the proposed Project. 21 Based on prciposed Site Plan prepared by Primior. LINSCOTT, I.Aw & GREENsPAN, engineers 32 (2) Existing Plus Project Traffic Conditions AM Peak Hour PM Peak Hour Max. Queue19 (ft.) 54' 311' 316' 206' Adequate Storage Yes/ No Yes No No Yes Max. Adequate Queue19 Storage (ft.) Yes/No 123" Yes 493' No 394' No 213' Yes ' LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit C to Exhibit 1 TABLE 7-2 YEAR 2028 PLUS PROJECT QUEUING ANALYSIS (I) Year 2028 Traffic Conditions AM Peak Hour PM Peak Hour Storage Max. Adequate Max. Adequate Provided Queue" Storage Queuell Storage Key Intersections n (ft.) (ft.) Yes/No (ft.) Yes/No I. Harbor Boulevard at 5th Street Northbound Left-Tum/"U-tum" 185' 50' Yes 141' Yes 2. Harbor Boulevard at I st Street Southbound Left-Tumf'U-tum" 245' 306' No 484' No Westbound Dual Left-Tum 310' 316' No 382' No Future Westbound Right-Tumu 213'25 ---- Source: Google E:orth. u n Maximum queue in feet (ft) is calculated by taking the 95'" Percentile Queue length (ft) in HCM 7. 24 A westbound right-Wm pocket at the intersection of Harbor Boulevard and I" Street will be constructed as pan of the proposed Project. 25 Based on proposed Site Plan prepared by Primior. (2) Year2028 Plus Project Traffic Conditions AM Peak Hour PM Peak Hour Max. Adequate Max. Adequate QueueU Storage Queuel-' Storage (ft.) Yes/No (ft.) Yes/No 67' Yes 156' Yes 336' No 550' No 344' No 438' No NoError! 211' Yes 232' Book:mar knot defined. Error! Bookmark not defined. Although the future 95th percentile queue length of232 feet during the PM peak hour would exceed the proposed pocket lenb>th of213 feet, there is an additional 27 feet of queue storage on westbound 1• Street between the end of the future right-tum pocket and Figueroa Street that would result in a total storage length of240 feet. which oould accommodate the forecasted queue length of232 feet. LINSCOTT, LAW & GREENSPAN, engineets 33 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit C to Exhibit 1 8.0 CONGESTION MANAGEMENT PROGRAM (CMP) COMPLIANCE ASSESSMENT This analysis is consistent with the requirements and procedures outlined in the current Orange County Congestion Management Program (CMP). The CMP requires that a traffic analysis be conducted for any project generating 2,400 or more daily trips, or 1,600 or more daily trips for projects that directly access the CMP Highway System (HS). As noted in Section 4.0 of this traffic study, the proposed Project is forecast to generate approximately 1,575 daily trip-ends, and therefore, does not require a CMP traffic analysis. The CMPHS includes specific roadways, which include State Highways and Super Streets, which are now known as Smart Streets. Therefore, the CMP traffic analysis requirements relate to the potential circulation effects only on the specified CMPHS. The intersection of Harbor Boulevard and I st Street (Intersection No. 2) is a CMP intersection, which would have required evaluation if the CMP threshold was exceeded. It should be noted that the City of Santa Ana LOS criteria and evaluation identified in Section 5.0 of this report is consistent with the Orange County CMP traffic analysis guidelines. The level of service results for the intersection are summarized in Tables 5-1 and 5-2 and indicate that the proposed Project will not require improvements at this location. LINSCOTT, LAW & GREENSPAN, engineers 34 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N . ...t700'.'.?:J47J7 - F11s1 !farbor \hx,:d U,,,e. S:mta A11a'R�rt'4737 First llarbor M1A.:d-L'se. S:mtl .\n� Traffic Stu.!; 10-13-D.doc Exhibit C to Exhibit 1 9.0 ROADWAY SEGMENT EVALUATION Per City of Santa Ana requirements, this section of the report analyzes the daily operating conditions of key roadway segments within the vicinity of the proposed Project. A total of one(!) key roadway segment within the City of Santa Ana have been selected for evaluation and consist of the following locations: A.Figueroa Street, between 5th Street and I st Street (City of Santa Ana) 9.1 Roadway Link Capacities The City of Santa Ana utilizes the methodology presented in the County Master Plan of Arterial Highways (MP AH) and the City of Santa Ana Circulation Element to determine LOS midblock locations, as summarized in Table 9-1. 9.2 Roadway Link Level of Service Criteria According to the City of Santa Ana, LOS D is the minimum acceptable condition that should be maintained for roadway segments. However, the City of Santa Ana has defined exceptions to this criteria in major development areas where LOS E is considered acceptable If the daily roadway V /C ratio results in unacceptable LOS conditions, a peak hour link analysis is conducted to determine if the roadway operates at a satisfactory service level during the peak hours. LINSCOTT, LAw&GREENSPAN, engineers 35 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N \.j.700\1�34737 -First Harbor :-.riwd Us,;,. Sant� A11n1Repc>1t147J7 First lfaibor Mixcd-U5e. Santa .\na Tmffic Stl1dy 1().23.23 doc Exhibit C to Exhibit 1 TABLE 9-1 ROADWAY SEGMENT CAPACITIES AND LEVEL OF SERVICE CRITERIA" Roadway Capacities Roadway Classification Lanes LOSA LOSB LOSC LOSD LOSE LOSF Principal Arterial 8D 45,000 52,500 60,000 67,500 75,000 >75,000 Major Arterial 6D 33,900 39,400 45,000 50,600 56,300 >56,300 Primary Arterial 4D 22,500 26,300 30,000 33,800 37,500 >37,500 Secondary Arterial 4U 15,000 17,500 20,000 22,500 25,000 > 25,000 Divided Collector 2D 9,000 12,000 15,000 20,000 22,000 > 22,000 Collector 2U 7,500 8,800 10,000 11,300 12,500 >12,500 26 Source: Guidance for Administration of the Orange County Master Plan of Arterials and Highways (2017). LINSCOTT, LAW & GREENSPAN, engineers 36 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana � ,-t70011:C.Jn37 -F1rs1 H:ubor \!iwd l;si!. Santa Ana'R-,,011'.1737 First H.trl\Cr M,�cd-U,e. Sa11ta .\n� Tr:iffic Study 10-23-2..l do,: Exhibit C to Exhibit 1 9.3 Roadway Segment Analysis Results 9.3.1 Existing Plus Project Analysis Table 9-2 summarizes the results of the Existing Plus Project daily analysis for the one (1) key roadway segment. The first column (1) in Table 9-2 presents a summary of existing daily traffic conditions. The second column (2) lists existing traffic conditions with the addition of traffic generated by the proposed Project. The third column (3) indicates whether the traffic associated with the Project will exceed the level of service thresholds defined in this report. Existing Traffic Conditions Review of Column I of Table 9-2 indicates that the one (1) key roadway segment currently operates at acceptable LOS A. Existing Plus Project Traffic Conditions Review of Columns 2 and 3 of Table 9-2 indicates that the one (I) key roadway segment is forecast to continue to operate at an acceptable service level on a daily basis with the addition of Project generated traffic to existing traffic and will not require improvements when compared to the LOS standards and thresho.lds specified in this report. ltNSCOTT, I.Aw & GREENSPAN, engineers 37 LLG Ref. 2-23-4737-1 First Harbor Mixed•Use Project, Santa Ana N ·--1700'22H7J7 -F1rs1 Harbor ,\[1,-.,d u�. S:mt� ,\na'R"J:'Ort'-H37 Fim !far!'Or :-.11�.,d-t.;se. Santa ,\n:t Traffic Stud,- 10-2J-2J.WC Exhibit C to Exhibit 1 TABLE9•2 ExiSTING PLUS PROJECT ROADWAY SEGMENT LEVEL OF SERVJCE SUMMARY (1) Eiisting Min. Traffic Conditions Acceptable Roadway No. or Daily LOS u Roadwav S........,ent Jurisdiction LOS Classification Lanes Volume A.Figueroa Street, between Santa Ana D Collector 2U 903 A 5lh Street and I"' Street LINSCOTT, LAW &GREEtlSPAN, engineers 38 (2) (3) Exceeds Existing Plus Project LOS Traffic Conditions Threshold Daily LOS Yes/No Volume 1,523 A No LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana Exhibit C to Exhibit 1 9.3.2 Year 2028 Plus Project Analysis Table 9-3 summarizes the results of the Year 2028 Plus Project daily analysis for the one (I) key roadway segment. The first column (I) in Table 9-3 presents a summary of Year 2028 Cumulative daily traffic conditions. The second column (2) lists Year 2028 Cumulative traffic conditions with the addition of traffic generated by the proposed Project. The third column (3) indicates whether the traffic associated with the Project will exceed the level of service thresholds defined in this report. Year 2028 Cumulative Traffic Conditions Review of Column I of Table 9-3 indicates that the one (I) key roadway segment is forecast to operate at acceptable LOS A with the addition of ambient traffic growth and cumulative projects traffic. Year 2028· Cumulative Plus Project Traffic Conditions Review of Columns 2 and 3 of Table 9-3 indicates that the one (I) key roadway segment is forecast to continue to operate at an acceptable service level on a daily basis with the addition of Project generated traffic in the Year 2028 and will not require improvements when compared to the LOS standards and thresholds specified in this report. LINSCOTT, LAW & GREENSPAN, enginee,s 39 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana N 147Q(J\22J�7J7 - F11s1 1-farbor M1\�d L'S!!, S:mt� Ana'R�poirl,1737 F11st I fo.rbor Mt�id-l/s�. Santa An� Tr;1ffic Study 10-23-ZJ do� Exhibit C to Exhibit 1 TABLE9-3 YEAR 2028 ROADWAY SEGMENT LEVEL OF SERVICE SUMMARY (I) Year2028 Traffic Conditions Min. Acceptable Roadway No.of Daily LOS Ke--Roadwr Se-ment Jurisdiction LOS Classification Lanes Volume A Figueroa Street, between 5th Street and 151 Street Santa Ana D Collector 2U 948 A LINSCOTT, LAW & GREENSPAN, engineers 40 (2) (J) Year 2028 Exceeds Plus Project LOS Traffic Conditions Threshold Daily LOS Yes/No Volume 1,568 A No LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana Exhibit C to Exhibit 1 10.0 CEQA ASSESSMENT OF VMT, ACTIVE TRANSPORTATION, & PUBLIC TRANSIT 10.1 Vehicle Miles Traveled (VMT) Screening Analysis The purpose of this Vehicle Miles Traveled (VMT) analysis is to evaluate the Project based on Senate Bill 743 (SB 743) requirements, as required in CEQA section 15064.3. The City of Santa Ana has adopted criteria for evaluating VMT impacts under CEQA, and they are presented in the City of Santa Ana Traffic Impact Study Guidelines (September 2019). There are three types of screening methods to effectively screen projects from project-level assessment: (I) Transit Priority Area (TPA) Screening; (2) Low VMT Area Screening; (3) Project Type Screening. Projects located within a TP A may be presumed to have a less-than-significant impact on VMT absent substantial evidence to the contrary. A TPA is defined as a half-mile area around an existing "major transit stop" (i.e., a site containing an existing rail transit station, ferry terminal served by bus or rail transit service, or the intersection of two or more major bus routes with a frequency of service interval of 15 minutes or less during the morning and afternoon peak commute periods), or an existing stop along a "high-quality transit corridor" (i.e., a corridor with fixed route bus service with service intervals no longer than 15 minutes during peak commute hours). To identify if a project is in a TPA, Appendix A (Santa Ana Transit Priority Areas) of the City's guidelines is reviewed. Residential and office projects located within a low VMT-generating area may be presumed to have a less-than-significant impact absent substantial evidence to the contrary. In addition, other employment-related and mixed-use land use projects may qualify for the use of screening if the project can reasonably be expected to generate VMT per resident, per worker, or per service population that is similar to the existing land uses in the low VMT area. To identify if a project is in a TPA, Appendix B (VMT/SP in Santa Ana as Compared to Orange County Average) and Appendix C (Santa Ana Development Areas that Cannot Be Screened) of the City's guidelines are used. Some project types have been identified as having the presumption of a less-than-significant impact absent substantial evidence to the contrary because their uses are local serving in nature, including local-serving retail uses with less than 50,000 SF, and projects generating less than 110 net daily trips. Based on the application of the City's screening criteria described above, and using Appendices A, B, and C in the City's guidelines, it was determined that the Project is located in a TPA (as shown on Figure 10-1) and is located in a low-VMT generating area (as shown on Figures 10-2 and 10-3); and is therefore screened out from further VMT project-level assessment because it can be presumed to have less-than-significant impact on VMT. 10.2 Active Transportation and Public Transit Screening Analysis Even though the City's traffic impact analysis guidelines do not specify the need for Active Transportation and Public Transit Screening Analysis, potential impacts to active transportation LINSCOTT, LAw&GREENSPAN, engineers 41 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Development. Santa Ana N ,-l70DU2J47J7 -First Haib"r Mi��d t;,�. SJnta Ana'R�po1t'47J7 First H.ul'Clr )..\,��d-Fse. Santa .-\n� TrJffic Stl1dy 10-}3-23,doc Exhibit C to Exhibit 1 --OC Metrolink Rail Half Mile Buffer around Metrolink Station Half Mile around High Quality Bus Stops Santa Ana SOURCE: CITY OF SANTA ANA �O SCALE FIGURE 10-1 SANTA ANA TRANSIT PRIORITY AREAS FIRST HARBOR MIXED-USE PROJECT, SANTA ANA 9 r "! I 0 Exhibit C to Exhibit 1 Garden Grove I / Fountain Valley Costa Mesa < -15% below OC Regional Average 0 to -15% below OC Regional Average -Higher than the OC Regional Average LINSCOTT LAW & GREENSPAN engineerc; �O SCALE Tustin Santa Ana " Edinger Ave Warner Ave MacArthur Blvd Irvine fg () SOURCE: CITY OF SANTA ANA FIGURE 10-2 VMT/SP IN SANTA ANA AS COMPARED TO ORANGE COUNTY AVERAGE FIRST HARBOR MIXED-USE PROJECT, SANTA ANA ;:i 0 N I ;:i I � "'.... <ii N <O Q. 9 "' • '! N I 0 " ....".. / "' • l 2 C � :f, � ·e5 e 0 " � "...." ...... "' "'/ R .. / c Exhibit C to Exhibit 1 Santa Ana TAZ VMT/ SP not at least 15% below County Average and is not inside of a Transit Priority Area SOURCE: CITY OF SANTA ANA FIGURE 10-3 SANTA ANA DEVELOPMENT AREAS THAT CANNOT BE SCREENED FIRST HARBOR MIXED-USE PROJECT, SANTA ANA ,,, g N I ,,, N I 0 9 ! ..; I 0 Exhibit C to Exhibit 1 (pedestrian and bicycle) and public transit facilities and circulation were evaluated in this report by determining whether the Project conflicts with adopted policies, plans, or programs regarding public transit, bicycle, or pedestrian facilities, or otherwise decreases the performance or safety of such facilities. Sidewalks are provided on both sides of the street throughout most of the City. Crosswalks, pedestrian push buttons, and pedestrian indication lights are provided at all signalized intersections adjacent to the Project site. The proposed Project plans to retain this existing pedestrian infrastructure. The proposed Project will encourage walking by integrating pedestrian connections internally, as well as to nearby activities. Pedestrian circulation would be provided via existing public sidewalks along Harbor Boulevard, 1st Street, and Figueroa Street within the vicinity of the Project. The proposed Project will protect the existing sidewalk along Project frontage on these roadways. The existing sidewalk system within the Project vicinity provides direct connectivity to the existing development located along major thoroughfares. Long-term bicycle storage for the residential and retail uses will be provided in two bike rooms, totaling 96 long-term bike spaces. An additional four ( 4) bicycle spaces will be provided for short term bicycle storage purposes. According to the City of Santa Ana Bikeway Master Plan, Class IV Cycle Tracks are planned on Harbor Boulevard and I st Street along the Project's frontage. Figure 1-1 illustrates the location of public transit stops near the Project site, and Section 3.3 (Existing Public Transportation) describes the public transit-rich setting for the Project. Based on the above, the proposed Project would not have an impact on the existing multimodal network; specifically, it would not: (I) conflict with a plan, ordinance, or policy related to bicycle, pedestrian, and public transit; (2) substantially increase hazards due to a geometric design feature; or (3) result in inadequate emergency access. The proposed site plan for the Project will maintain existing sidewalks and access to public transit, construct new pedestrian connections on site and with adjoining uses, and meet City design standards regarding site access, multimodal connectivity within the internal site circulation system, emergency access, and on-site parking. LINSCOTT, LAW & GREENSPAN, engineers 42 LLG Ref. 2-23-4737-1 First Harbor Mixed.Use Development, Santa Ana N 1+700\'.'.'.'J47J7 • Firs, H,ubor Mix�d llse, Santa ,\11,1'R�1:>01t'.17J7 first I/arbor �11,ed-lisc, Santa ,\na Tr.iffic Study 10-23-23 doc Exhibit C to Exhibit 1 11.0 PARKING ANALYSIS AND PARKING MANAGEMENT PLAN {PMP) 11.1 City Code Parking Requirements City Code parking requirements for the Project were calculated based on the parking ratios from Table 3-7 (Off-Street Parking Standards) on Page 3-11 of the October 2014 Harbor Mixed Use Transit Corridor Plan for the Transit Node District. Table 11-1 presents a summary of the parking ratios applied to calculate the City Code requirements for residents, residential guests, and non residential/retail uses. As indicated on Table 11-1, the application of Specific Plan parking ratios to the various Project components results in a total City Code requirement of 313 spaces. Comparing this Code requirement against the proposed parking supply of 333 standard spaces results in a Code-based surplus of 20 spaces. Based on this, the Project's parking supply provisions would be adequate in meeting the City Code requirements for the Project. 11.2 Parking Management Plan (PMP) A PMP defines how parking for a development would be managed and what measures would be implemented to assure that parking needs in the aggregate and in localized sub-areas would be adequately served. A TOM Program identifies measures that could potentially reduce parking needs through the provision of physical and/or operational improvements that promote the use of alternative modes of travel (i.e., public transit, bicycle, walking). Recommendations for PMP measures are provided in this study to ensure competing parking needs for all Project tenants, guests, and employees are adequately managed and controlled to facilitate parking efficiency. Implementation of PMP measures will help ensure that the Project's parking supply will be sufficient, convenient/accessible, responsive to varying demand, and provide parking contingencies in meeting the parking needs of all users (i.e., residential, retail). It is recommended that when the Property Owner and/or Property Management Company deems it necessary, the following key Parking Management Strategies be implemented by the Property Owner and/or Property Management Company: •The PMP should identify where the retail/commercial employees park within the site. •The PMP should identify where location of short-term parking spaces for service retail usesand/or food uses (take-out/curb side service, etc.). •The PMP should direct residents to park in their assigned spaces and provide parking toaccommodate resident guest parking needs. •The PMP should restrict vehicles from exceeding the time restriction on any short-term parking. •The PMP should provide rules of conduct for tenants and guests to abide by. Strict enforcementshall be adhered to. LINSCOTT, LAW & GREENSPAN, engineers 43 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana N'·.4700\2234737-Firn Harbor M,x�d L'se. Santa AnJ'R�pcn'47J7 F1rs.t H�.rbor M,x�d-l's.c,, Snnt-1 Ana Tmffic Study l0-�3-23.doc Exhibit C to Exhibit 1 TABLE 11-1 CITY CODE PARKING REQUIREMENTS27 Spaces Project Description Size Code Parking Ratio Required Residential . Residents 183 DU I parking space for dwelling unit 183 Spaces . Residential Guests 183 DU 0.5 visitor spaces per dwelling unit 92 Spaces . Residential Guests 15,182 SF I parking space per 400 SF 38 Spaces Total Code Parking Requirement: 313 Spaces Proposed Parking Supply: 333 Spaces Total Parking Surplus(+) or Deficiency(-): +20 Spaces 27 Source: City of Santa Ana parking ratios from Table 3-7 (Off-Street Parking Standards) on Page 3-11 of the October 2014 Harbor Mixed Use Transit Corridor Plan for the Transit Node District LINSCOTT' LAW & GREENSPAN, engineers 44 LLG Ref 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana Exhibit C to Exhibit 1 •The PMP should adopt the mindset with the following parking goals: 1.Meet or exceed the minimum requirements for total parking spaces for the Project's retail/commercial component, as well as the residential component. 2.Provide all resident and guest parking spaces onsite. 3.Provide flexible on-site parking opportunities for commercial and resident parking that respect both commercial tenants and guest parking needs. 4.Enact policies that promote parking efficiencies and effective communication between Property Management, commercial tenants and residents. 5.Enact policies of enforcement by Property Management that are sufficiently flexible to meetcurrent and changing parking demands, while imposing penalties, if necessary. 11.3 PMP Measures The following measures are available to the Project to mitigate any parking impacts or deficiencies in the event the proposed on-site parking supply is determined to be greater than what is provided. Retail/Commercial Component 1.The Property Owner/Property Management Company will implement a reciprocal parking program to ensure the pool of parking for the retail/commercial component and guest of the residential component is available to be "shared". 2.The Property Owner/Property Management Company will work with tenants of the retail uses toimplement an employee parking program, with the goal of providing convenient and accessible shopping experience for the customers of the retail uses, and to leave the most desirable parkingspaces within the parking structure for use by customers. The location of designated employeeparking spaces will be developed in collaboration between Property Owner/PropertyManagement Company and the tenants. The employee parking spaces will be identified with awhite or yellow circle, and/or other signage recommended by the the Property Owner/PropertyManagement Company. It is noted that these spaces will be open for customer use. 3.The Property Owner/Property Management Company will work with tenants of the retail uses toidentify the need for "short term/time restricted spaces" on an as need basis, dependent on theneeds of the proposed retail and/or food use. These short-term spaces will most likely bedesignated along the internal roadways. The short-term spaces may be used for "curbside/takeout" and/or for service retail-type users. The number and location of spaces will be determinedby Property Owner/Property Management Company and the potential tenants. 4.If the Property Owner/Property Management Company determines additional parking is neededto meet the parking requirements of the retail/commercial component of the Project and/ordesires to provide "enhanced customer service", the Property Owner/Property ManagementCompany shall implement a valet/valet assist program. The hours of operation of the valet/valetassist program will be determined by the Property Owner/Property Management Company, andsubject to actual demand, may include weekdays and weekends, between the period 11 :00 AMand 2:00 PM and 5:00 PM to 10:00 PM, to enhance the customer experience accommodate the"lunch time" and "dinner" crowd of the proposed restaurant/food uses. LINSCOTT, LAW & GREENSPAN, engineers 45 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana N ,-H00'1:H7J7 • F1rs1 Hmbor Miwd u,�, S:uua �na'RcpouL-1737 F11�1 H.ulior Mt>,etl-Use. Silnta .\na TrJflic Sh1dy !O-D-23.doc Exhibit C to Exhibit 1 Residential Component 5.The Property Owner/Property Management Company shall determine the allocation of parking spaces for resident tenants and location of guest parking spaces, and assign residential parking spaces accordingly. 6.The Property Owner/Property Management Company, if deemed necessary, may allow resident guest to utilize the valet program identified in Measure No. 4, as an enhanced service. Toimplement the valet operation, the Property Owner/Property Management Company would engage the services of a well-established valet operations company similar to PMP measure No. 4. 7.Every resident will be required to register their vehicle. The registered owner must be a lease holding resident. This registration will be updated annually at the time of recertification. If valid registration is not obtained from the Property Owner/Property Management Company, the vehicle may be towed at the owners' expense. 8.Vehicles lacking current registration may be towed by the Property Owner/Property Management Company. The storage of inoperable or unregistered vehicles is prohibited. 9. If a resident obtains a new vehicle, the resident must provide new registration (transferring registration is not permissible). 10.Vehicles may not occupy unassigned spaces for more than twenty-four (24) hours, without contacting the leasing office in advance. Violators are subject to towing at the vehicle owner's expense. 1 I. Resident guests will be able to park, on a first-come-first-served basis, within the spaces designated for guest parking. 12.Violation of the PMP strategies contained herein may result in the towing of the vehicle at thevehicle owner's expense. 13.The enforcement of resident and resident guest parking on-site parking requirements summarized herein will be handled by the Property Owner/Property Management Company to ensure compliance. Retail/Commercial & Residential Component 14.To enhance efficient and comfortable movement of all users throughout the site, and access to parking spaces and valet pick-up/drop-off staging areas (if implemented), and support "Park Once" strategies, provide a detailed wayfinding/signage program that meets City standards and requirements. ltNSCOTT, LAW & GREENSPAN, engineers 46 LLG Re[ 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana Exhibit C to Exhibit 1 15.The parking conditions for the Project will be reviewed/monitored on a quarterly basis by the Property Owner/Property Management Company and appropriate actions detailed above will be taken to ensure that the necessary PMP measures are being implemented. 16.Designate areas on site for quick and efficient pick-up and drop-off of passengers to facilitate ridesharing and use of rideshare services such as Uber and Lyft. LINSCOTT, LAW & GREENSPAN, engineers 47 LLG Ref 2-23-4737-1 First Harbor Mixed•Use Development, Santa Ana Exhibit C to Exhibit 1 SUMMARY OF FINDINGS AND CONCLUSIONS •Project Description -The First Harbor Mixed-Use Project proposes to develop a nine-story building with 183 multifamily residential units (including studios, I-bedroom, 2-bedroom, and 3- bedroom units) and 15,182 SF of retail on the ground floor. Of the 183 total units proposed, 15% (28 units) would be designated as low-income housing. The residential and retail uses would wrap around a four-level parking structure, consisting of two subterranean levels, one street/ground level, and a second above-ground level, and provide a total of 333 standard parking spaces. As presented previously, Figure 1-1 is the Vicinity Map, which shows the general location of the Project and surrounding street system. Figure 2-1 is an existing aerial photograph of the Project site. The Project is expected to be completed and fully occupied by Year 2028. As part of the Project-specific improvements planned at the intersection of Harbor Boulevardand !st Street (Intersection No. 2) previously approved by the City, the Project will be adding aright-turn pocket (with a total length of213 feet, comprised of 186 feet of storage length, and 27feet of transition length) along I st Street on the westbound approach of the intersection. •Study Scope -The following two (2) key study intersections and one (I) key roadway segmentwere selected for detailed peak hour level of service analyses under Existing Traffic Conditions,Existing Plus Project Traffic Conditions, Year 2028 Cumulative Traffic Conditions and Year2028 Cumulative plus Project. Kev Study Intersections 1.Harbor Boulevard at 5th Street (City of Santa Ana)2.Harbor Boulevard at I st Street (City of Santa Ana) Kev Roadway Segments A.Figueroa Street, between 5th Street and I st Street (City of Santa Ana) •Existing Traffic Conditions -All key study intersections currently operate at an acceptable levelof service (LOS) during the AM and PM peak hours when compared to the LOS criteria definedin this report. •Project Trip Generation -The proposed Project is forecast to generate approximately 1,575daily trips, with 100 trips (36 inbound, 64 outbound) produced in the AM peak hour and 131trips (73 inbound, 58 outbound) produced in the PM peak hour on a "typical" weekday. •Related Projects Traffic Characteristics -Ten (10) related projects were considered as part ofthe cumulative background setting. The ten (10) related projects are forecast to generate 4,705 daily trips, with 245 trips (103 inbound, 142 outbound) anticipated during the AM peak hour and287 trips (162 inbound, 125 outbound) produced during the PM peak hour. LINSCOTT, LAW & GREENSPAN, engineers 48 LLG Ref 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana :>: . .4700 �13HJ7 -Fitsr Harbor ;l,li>..:d t·se, S:uua Ana R�µorrHJ7 Fir.<t Ha.rl>or \h>..:d-Llse. Santa .-\na Tr�ffic $1uJ} I0-23-23 doc Exhibit C to Exhibit 1 •Existing Plus Project Traffic Conditions -The traffic associated with the proposed Project willnot require improvements at any of the two (2) key study intersections, when compared to theLOS standards and thresholds specified in this report. The two (2) key study intersections areforecast to operate at LOS D or better during the weekday AM and PM peak hours with theaddition of Project traffic. •Year 2028 Cumulative Traffic Conditions Plus Project -The traffic associated with theproposed Project will not require improvements at any of the two (2) key study intersections,when compared to the LOS standards and thresholds specified in this report. The two (2) keystudy intersections are forecast to continue to operate at acceptable levels of service (LOS D orbetter) during the AM and PM peak hours with the addition of Project traffic to Year 2028Cumulative traffic conditions. ■ Site Access Assessment -Harbor Boulevard at Project Driveway I and Figueroa Street at ProjectDriveways 2 and 3 are forecast to operate at LOS D or better during the AM peak hour and PMpeak hour. As such, Project access will be adequate. Motorists entering and exiting the Projectsite will be able to do so without undue congestion. Furthermore, the anticipated queues at eachof the Project driveways are anticipated to be no more than one (I) vehicle during the AM andPM peak hours. To supplement the level of service analysis, a gap analysis has been completed along Harbor Boulevard as well as at the intersection of Figueroa Street at I st Street to determine if the existing gaps along the main arterial roadways are considered adequate to accommodate ingress and egress at the proposed Project driveways. The gap analysis indicates that there are more gaps than vehicles exiting, therefore, it can be concluded that both right-turning and left-turning vehicles will have adequate gaps along Harbor Boulevard and/or I st Street when exiting the Project site. •Sight Distance Evaluation -Sight lines for the southbound movements at the intersection ofFigueroa Street at l't Street, as well as at Project Driveway 1, along Harbor Boulevard, areexpected to be adequate. Sight lines at Project Driveways 2 and 3, along Figueroa Street, will beobstructed by vehicles parked on-street along Figueroa Street. As a result, it is recommended torestrict on-street parking along the Project frontage of Figueroa Street to help facilitate andenhance visibility for outbound vehicles. •Queuing Assessment -Adequate queue storage length is currently provided for the northboundleft-turn/"U-turn" lane located at the intersection of Harbor Boulevard and 5t h Street based on theanticipated maximum 95th percentile queue length under Existing, Existing plus Project, Year2028 Cumulative and Year 2028 Cumulative plus Project traffic conditions. Although the existing and future 95th percentile queues reported for the southbound left-turn/"U turn" and westbound left-turn movements at the intersection of Harbor Boulevard and 1 st Street exceed the existing storage lengths for the respective movements, these are existing queue storage deficiencies not caused by the Project. The 95th percentile queue lengths are LINSCOTT, LJ\w&GREENSPAN, engineers 49 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana I< ,-1700t:!1j 1737 - First H:1rbo1 \li>.ed l 'se. San\3 Ana·RcporH737 Fir;t H.ll l,or \(v.,:d.t:se. Sant:i .\ria Tr;iffic Study ID-23-2J doc Exhibit C to Exhibit 1 conservative estimates of potential queues. It should be noted further that the Project-generated traffic that could be added to the southbound and westbound left-tum movements are nominal (i.e., southbound left-tum: 15 AM peak hour trips, 36 PM peak hour trips; westbound left-tum: 11 AM peak hour trips, 16 PM peak hour trips), corresponding to a maximum of one vehicle on a given cycle. Adequate queue storage length would be provided for the planned westbound right-tum pocket at the intersection of Harbor Boulevard and I st Street based on the anticipated maximum 95th percentile queue length under Existing plus Project, and Year 2028 Cumulative plus Project (during the AM peak hour only) traffic conditions. Although the future 95th percentile queue length of 232 feet during the PM peak hour would exceed the proposed pocket length of 213 feet, there is an additional 27 feet of queue storage on westbound I st Street between the end of the future right-tum pocket and Figueroa Street that would result in a total storage length of 240 feet, which could accommodate the forecasted queue length of 232 feet. Based on the considerations above, improvements are not recommended. ■Existing Plus Project Roadway Segment Evaluation -The roadway segment at Figueroa Street,between 5th Street and I st Street is forecast to continue to operate at an acceptable service levelon a daily basis with the addition of Project generated traffic to existing traffic and will not require improvements when compared to the LOS standards and thresholds specified in thisreport. •Year 2028 Cumulative Plus Project Roadway Segment Evaluation -The roadway segment atFigueroa Street, between 5th Street and I st Street is forecast to continue to operate at anacceptable service level on a daily basis with the addition of Project generated traffic in the Year2028 and will not require improvements when compared to the LOS standards and thresholdsspecified in this report. •VMT Screening Assessment -Based on the application of the City's screening criteria, andusing Appendices A, B, and C in the City's guidelines, it was determined that the Project islocated in a TP A and is in a low-VMT generating area; and is therefore screened out from furtherVMT project-level assessment because it can be presumed to have less-than-significant impactonVMT. ■Parking Analysis and PMP -The application of Specific Plan parking ratios to the variousProject components results in a total City Code requirement of 313 spaces. Comparing this Coderequirement against the proposed parking supply of 333 standard spaces results in a Code-based surplus of 20 spaces. Based on this, the Project's parking supply provisions would be adequatein meeting the City Code requirements for the Project. LINSCOTT, LAW & GREENSPAN, engineers 50 LLG Ref 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana K.,.t70011'.::H737 - F,rsc Harbor \11,�d u�. S:111u ,\na··R�port�HJ7 Fnst HarlXlr �lix�d-l'�-S:mu .\n� Traffi� StuJ; l0-:?.3-2J.doc Exhibit C to Exhibit 1 Recommendations for PMP measures are provided in this study to ensure competing parking needs for all Project tenants, guests, and employees are adequately managed and controlled to facilitate parking efficiency. LINSCOTT, LAW & GREENSPAN, engineers 51 LLG Ref 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana \' -1700\�234737 -First Harbor \.��,:<I Cs.,;,. Santst AnJ\R�p,:m'47J7 First !-1:u·lxir M1�cd-l'.s.!. Santa .\n:i Tr�flic Study 10-2J-2J do� Exhibit C to Exhibit 1 Resolution No. 2024-XX Page 1 of 9 RESOLUTION NO. 2024-XX A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF SANTA ANA APPROVING TENTATIVE TRACT MAP NO. 2024-01 AS CONDITIONED FOR A MIXED-USE DEVELOPMENT AT 101, 111, 115, AND 121 NORTH HARBOR BOULEVARD, 3709 AND 3729 WEST FIRST STREET, AND 114 NORTH FIGUEROA STREET (APNS: 198-182-37 AND 198-182-38) BE IT RESOLVED BY THE PLANNING COMMISSION OF THE CITY OF SANTA ANA AS FOLLOWS: Section 1. The Planning Commission of the City of Santa Ana hereby finds, determines, and declares as follows: A.Charles ‘Chuck’ Minyard with Primior, Inc. and representing Harbor and First, LLC (“Applicant” and “Property Owner”) is requesting approval of Site Plan Review (“SPR”) No. 2024-01 and Tentative Tract Map (“TTM”) No. 2024-01 to facilitate the construction of a mixed-use development (“Project”) known as First Harbor Mixed-Use Development located at 101 North Harbor Boulevard “Project Site”). B.The Project entails, among other improvements; (1) development of the Project Site with a mixed-use building with two subterranean parking levels and nine stories above grade containingn15,182 square feet of leasable commercial space, 1,845 square feet of leasing office space, 181 for-sale residential condominium units, 339 parking spaces, and 40,853 square feet of open space and amenities, (2) approval of SPR No. 2024- 01; and (3) approval of Tentative Tract Map (“TTM”) No. 2024-01, to be considered by the Planning Commission on March 25, 2024 by way of a separate resolution. C.The Project Site has a General Plan land use designation of District Center – High (“DC-5”) and is located within the Transit Node South (“TNS”) district of the Harbor Mixed-Use Transit Corridor Specific Plan (“SP-2”). D.Subdivision requests are governed by Chapter 34 and Chapter 41 of the Santa Ana Municipal Code (“SAMC”) and the California Subdivision Map Act (“SMA”). E.Pursuant to Section 34-127 of the SAMC, approval of a TTM application by the Planning Commission is required for projects proposing to create four or more parcels. F.The City previously certified the Final Environmental Impact Report (“EIR”), adopted a Mitigation Monitoring and Reporting Program, adopted a Statement of Overriding Considerations, and approved the 2014 Harbor Exhibit 2 Resolution No. 2024-XX Page 2 of 9 Boulevard Mixed-Use Transit Corridor Plan Environmental Impact Report (EIR) (SCH No. 2013061027) on October 21, 2014 (Resolution No. 2014- 069)pursuant to the California Environmental Quality Act (“CEQA”). G.Pursuant to State CEQA Guidelines section 15162, a lead agency shall consider whether additional CEQA review is required when considering a subsequent discretionary approval for a project for which an EIR was certified. H.The Planning Commission has independently reviewed and considered the previously certified EIR and other documents in the record before it. I.On March 25, 2024, the Planning Commission of the City of Santa Ana held a duly-noticed public hearing on TTM No. 2024-01. J.The Planning Commission of the City of Santa Ana determines that the following findings, in accordance with Section 66473.5 and 66474 of the SMA and Section 34-127 of the SAMC, which must be established in order to approve TTM No. 2024-01, have been established: 1.The proposed project and its design and improvements are consistent with the General Plan land use designation and are otherwise consistent with all other Elements of the General Plan. The Project supports several goals and policies of the General Plan. Specifically, the Project is consistent with Economic Prosperity Element (EP) Policy EP-3.4 which encourages the development of “complete communities” that provide a range of housing, services, amenities, and transportation options that support the retention and attraction of skilled workforce and employment. Goal 1 of the Land Use Element (LU) encourages projects that improve quality of life and respects the existing community. Policy LU-1.2 supports innovative development policies to expand homeownership opportunities at all income levels. Policy LU-1.6 encourages residential mixed-use development, within the City’s District Centers, Urban Neighborhoods, and adjacent to high quality transit. Policy LU-2.2 encourages the development of a range of commercial uses to capture a greater share of local spending and that offer a range of employment opportunities. Policy LU-2.5 encourages infill mixed-use development at all ranges of affordability to reduce vehicle miles traveled, improve jobs/housing balance, and promote social interaction. Policy LU-4.7 encourages the development of mixed-income developments with mixed housing types to create inclusive communities and economically diverse neighborhoods. Policy UD-1.1 of the Urban Design Element (UD) requires that all developments feature high quality design, materials, finishes, and Exhibit 2 Resolution No. 2024-XX Page 3 of 9 construction. Policy UD-2.2 encourages buffers and other urban design strategies to encourage computability of new development with the scale, bulk, and pattern of existing development. Lastly Policy HE-2.5 of the Housing Element (HE) encourages the creation of higher intensity, mixed-use urban villages and pedestrian-oriented experiences that access and support the office centers, commercial services, and cultural activities within District Centers and Urban Neighborhood designated areas. Policy HE-2.5 supports diverse types, prices, and sizes of housing and Policy HE- 2.6 supports excellence in architecture design through the use of materials and colors, building treatments, landscaping, open space, parking, and environmentally sensitive building and design practices. 2.The proposed project conforms to all applicable requirements of the zoning and subdivision codes as well as other applicable City ordinances. The Project is consistent with the development standards specified within SP-2, including land use, height, minimum development site area, building frontages, private/common open space, building setbacks, and parking and access. The Project is a mixed-use development that has been well designed to fit within the TNS District. Further, the access and egress for the Project has been thoroughly review by the Public Works Agency for compliance with all applicable regulations. 3.The project site is physically suitable for the type and density of the proposed project. The Project Site is physically suitable for the type and density of the Project. There are no physical constraints on the site that would preclude development. The Project Site consists of approximately 1.56 acres of land and is physically suitable for the Project. The lot size, density, width, and lot coverage are consistent with the TNS development standards. 4.The design and improvements of the proposed project will not cause substantial environmental damage or substantially and avoidably injuries to fish or wildlife of their habitat. The design and improvements of the Project will not cause substantial environmental damage or substantially and avoidably injure fish and wildlife or their habitat. The Project is located in an urbanized area, and there are no known fish or wildlife populations existing on the Project site. Therefore, the subdivision will not cause any substantial environmental Exhibit 2 Resolution No. 2024-XX Page 4 of 9 damage or substantially and avoidably injure fish and wildlife or their habitat. 5. The design or improvements of the proposed project will not cause serious public health problems. The design or improvements of the Project will not cause serious health problems. The subdivision will not have any detrimental effects upon the general public. The property will include necessary utilities and infrastructure improvements as required by the SAMC and SMA. 6. The design or improvements of the proposed project will not conflict with easements necessary for public access through or use, of property within the proposed project. The design and improvements of the Project will not conflict with easements necessary for public access or use of the property within the Project. In addition, the CC&Rs will ensure reciprocal access rights and maintenance agreements between properties. Section 2. The Applicant shall indemnify, protect, defend and hold the City and/or any of its officials, officers, employees, agents, departments, agencies, authorized volunteers, and instrumentalities thereof, harmless from any and all claims, demands, lawsuits, writs of mandamus, and other and proceedings (whether legal, equitable, declaratory, administrative or adjudicatory in nature), and alternative dispute resolution procedures (including, but not limited to arbitrations, mediations, and such other procedures), judgments, orders, and decisions (collectively “Actions”), brought against the City and/or any of its officials, officers, employees, agents, departments, agencies, and instrumentalities thereof, that challenge, attack, or seek to modify, set aside, void, or annul, any action of, or any permit or approval issued by the City and/or any of its officials, officers, employees, agents, departments, agencies, and instrumentalities thereof (including actions approved by the voters of the City) for or concerning the Project, whether such Actions are brought under the Ralph M. Brown Act, California Environmental Quality Act, the Planning and Zoning Law, the Subdivision Map Act, Code of Civil Procedure sections 1085 or 1094.5, or any other federal, state or local constitution, statute, law, ordinance, charter, rule, regulation, or any decision of a court of competent jurisdiction. It is expressly agreed that the City shall have the right to approve the legal counsel providing the City’s defense, and that Applicant shall reimburse the City for any costs and expenses directly and necessarily incurred by the City in the course of the defense. City shall promptly notify the Applicant of any Action brought and City shall cooperate with Applicant in the defense of the Action. Section 3. The Planning Commission has reviewed and considered the information contained in the certified EIR and all supporting documentation, copies of which are on file at the Planning Department and are incorporated by reference as though set forth fully herein. Based on this review, the Planning Commission finds that any comments received regarding Project have been examined and determined to not Exhibit 2 Resolution No. 2024-XX Page 5 of 9 modify the significant conclusions of the EIR. The Planning Commission further finds that no additional feasible mitigation measures within the City’s authority are necessary to reduce the environmental impacts of the Project, because all impacts of the Project are either less than significant, will be mitigated to a level of less than significant through compliance with the existing mitigation, or remain significant and unavoidable even with the imposition all of feasible mitigation and all applicable mitigation measures, attached hereto as Exhibit B applied to the certified EIR and will be applied to the Project. Finally, based on the substantial evidence set forth in the record, including but not limited to the certified EIR, the Planning Commission finds that none of the conditions triggering the need for subsequent environmental review have occurred. Specifically, the Planning Commission finds that no subsequent environmental review is required pursuant to State CEQA Guidelines section 15162 because: a. No substantial changes are proposed by the Project which will require major revisions of the EIR due to the involvement of new significant environmental effects or a substantial increase in the severity of previously identified significant effects; b. No substantial changes have occurred with respect to the circumstances under which the Project is being undertaken which will require major revisions of the EIR due to the involvement of new significant, environmental effects or a substantial increase in the severity of previously identified significant effects; and c. No new information of substantial importance, which was not known and could not have been known with the exercise of reasonable diligence at the time the EIR was certified, shows that: (i) either the Project will have one or more new significant effects; (ii) significant effects of modifications to the Project examined in the EIR will be substantially more severe; (iii) mitigation measures or alternatives previously found not to be feasible would in fact be feasible and would substantially reduce one or more significant effects of the Project, but the City declined to adopt the measure or alternative; or (iv) mitigation measures or alternatives which are considerably different from those analyzed in the EIR would substantially reduce one or more significant effects on the environment, but the City declines to adopt the measure or alternative. Section 4. The Planning Commission directs staff to file a Notice of Determination with the County Clerk’s Office and with the State Clearinghouse within five (5) working days of adoption of this Resolution. Section 5. This Resolution shall not be effective unless and until the Planning Commission Resolution for Site Plan Review No. 2024-01 is adopted and becomes effective. If said Resolution is for any reason held to be invalid or unconstitutional by the decision of any court of competent jurisdiction, or otherwise does not go into effect for any reason, then this Resolution shall be null and void and have no further force and effect. Section 6. The Planning Commission of the City of Santa Ana, after conducting the public hearing, hereby approves TTM No. 2024-01, as conditioned in Exhibit A, attached hereto and incorporated herein for the Project at the Project Site, and as illustrated and attached hereto and incorporated herein as Exhibit B. This decision is based upon the evidence submitted at the above said hearing, which includes, but is not limited to: The Request for Planning Commission Action dated March 25, 2024, and Exhibit 2 Resolution No. 2024-XX Page 6 of 9 exhibits attached thereto; and the public testimony, written and oral, all of which are incorporated herein by this reference. ADOPTED this 25th day of March, 2024 by the following vote: AYES: Commissioners: NOES: Commissioners: ABSENT: Commissioners: ABSTENTIONS: Commissioners: _______________________ Bao Pham, Chairman APPROVED AS TO FORM: Sonia R. Carvalho, City Attorney By:________________________ Laura Rossini Chief Assistant City Attorney Exhibit 2 Resolution No. 2024-XX Page 7 of 9 CERTIFICATE OF ATTESTATION AND ORIGINALITY I, NUVIA OCAMPO, Recording Secretary, do hereby attest to and certify the attached Resolution No. 2024-XX to be the original resolution adopted by the Planning Commission of the City of Santa Ana on March 25, 2024. Date: ________________ ____________________________________ Nuvia Ocampo Recoding Secretary City of Santa Ana Exhibit 2 Resolution No. 2024-XX Page 8 of 9 Exhibit A Conditions for Approval for Tentative Tract Map No. 2024-01 Tentative Tract Map No. 2024-01 is approved subject to compliance, to the reasonable satisfaction of the Planning Manager, with all applicable sections of the Santa Ana Municipal Code, the California Administrative Code, the California Building Standards Code, and all other applicable regulations. The Applicant shall comply with each and every condition listed in order to exercise the rights conferred by this tentative tract map. The Applicant shall remain in compliance with all conditions listed below throughout the life of the development Project. Failure to comply with each and every condition may result in the revocation of the tentative tract map. 1. All site improvements shall conform to the Development Project Review (DP) No. 2023-08, and the staff report exhibits incorporated herein by reference. 2. Any amendment to this tentative tract map shall be submitted to the Planning Division for review. At that time, staff will determine if administrative relief is available or if the tentative tract map must be amended. 3. The Project shall comply with all recommendations contained with the technical studies and reports prepared for the Project. All studies and reports shall be finalized by the Applicant and approved by the City of Santa Ana prior to the issuance of any building permits. 4. The Project shall comply with all applicable mitigation measures as identified by the Mitigation Monitoring and Reporting Program of the 2014 Environmental Impact Report (EIR) (SCH No. 2013061027), attached hereto as Exhibit C. 5. The parking management measures as identified by the Parking Study and Parking Management Plan (PMP), attached hereto as Exhibit D, shall be incorporated into the Project and shall apply through the life of the Project. The objectives of the PMP are intended to: a. Restrict residents from parking in the guest spaces; b. Restrict guests from parking in the reserved resident spaces and require guests to park in designated guest spaces; c. Restrict vehicles from exceeding the time restriction on the short term parking; d. Allow for the use of “short-term/time restricted” parking spaces allocated to the retail and leasing office for use by residents and resident guests after business hours, as necessary; Exhibit 2 Resolution No. 2024-XX Page 9 of 9 e. Develop the framework for parking agreements between the leasing office and the tenants; and f. Prevent residents, guests, and commercial patrons, from parking in the neighborhood. In the event that documented and sustained street parking issues arise in the adjacent single-family neighborhood after full Project occupancy, the Applicant shall facilitate the establishment of a parking permit district for the neighborhood, including preparation of a petition, gathering property owner signatures, and completing document/analysis as required by the Public Works Agency, at the Applicant’s full and sole expense. 6. The Applicant shall submit Covenants, Conditions and Restrictions (CC&Rs) for the Project to the Planning Division for review and approval prior to the Final Map being recorded. 7. The Final Map shall be approved and recorded prior to issuance of Building permits. 8. The Final Map and all improvements required to be made or installed by the subdivider shall be in accordance with the design standards and specifications of the Santa Ana Municipal Code and the requirements of the State Subdivision Map Act. 9. Within 10 days of recordation of the Final Map and CC&Rs, a copy shall be submitted to each of the following departments: Planning Division, Building Division, Public Works Agency and Orange County Fire Authority (OCFA). Exhibit 2 ii .. i' z I I I I '" I I I ' I ' 1 ' TENTATIVE TRACT MAP NO. 1927 4 FOR CONOOMNUM PUAPOSES LEGEND Cl<._..,----� .,..,.,, ' :--=, = J..0:.,/«l-• • (<_ , -----�M�-�--�� ::--�··�� �ff "'J -=" t, I <.!!. CITY OF SANTA mA. COUNTY OF ORANGE, STATE OF CALFOANA 'l!l!Cll(U(; ... , '9l:1'01tOIOl1Cf _.I\ICK!IC%0ml,001r') Ul!ilfl<.,-...,lr.JUI i t ' s ' -' '�J'""'i.1 �! .,, I ( I" (d:l,O,IUIIC {11.-JtllClltk\t- L ar-.L,ut,.�,�-���!�cccl1esac1r---t-�-1 ,� _,.,,.,/_o� Cl<IIU.Y QJTT{a (2"J'-) � ,,n,::ooc-.-�,s. Mlt)ul-.ilY{•SlM(Nl t J«!ll',, IMPROVEMENT NOTES --'---+------·--_--.n__! _ I 1���ET ____ • 1 __ I I I I f WSIIMC (ASIVOO MOTE:$ 0 !�J?����l�t,..!'°:"'��'":l 0 @ =c;� =�;1z�!��i:'S:L�= :=!M. (i) ��!i��ftf��.:'o?oo�c::l NC .ao� 0 �-�..:��a::r��J��._,_.,-'IIIOIH(C(l':.,,i,"'-""'0$($-D © :�:�..:,��?'",=:!'�� ��or��C:SIMCWo""- � © :�::�����o:_::;r,.::����<-Ul't.\.� 0 :=::.t"i:-•-:!;o-.. -:o.���:-(ll��y ""° ..co(HT .... � 0· � ��• =· � 4�,W���lltiCl-:,."f��i �,:�� .. � Cl'm&ot or om:;.,. -� (JO. �DJ (Ff����!�-:::�,=�'°"��$:�:-.:...:! II. )d)1 .. omc:1111. r,ao;,::,$ � IN>lll!,,l,UJI "° Ml(IW""'-1 00 Qfl,C,"'-<It� ( {IO 9l W,l�lll @f :;��� �': � � � ': � g.:�� :"'°°"""°' �#l;-A,,.�'IIOt<fc-1 l\ll\.llllf.SlllC[1cCfl_,,,,_5Ntl,'!Ms,,,,n/r,tl'rV'll(l!S -, Sll)f!W l)iMNS "'° -.s � "'I: cc,,,o,.,,is.. ClliiU$. •.fliS. "O.U IHI Qflli.11 � �AC$ ll(COJl:OCC _,.-., l•, 100I .. Ol"l'Oirt .COJll)S ..s >IStliltJWOI" � :IOC� Q" cmt•••· •� (IO K wr.::t.AMW). PSQPOSCD fASiNOO HQID 0 =:lt��-%"'=[11flt::t'ICI' ',(M(y ..... IICQ'SS w;, rlll' © --00..us,,( lNlOIOfl ..U..JM'.D , 0'I 1111111$ #IH'.l .-:'I (lllM LEGAL DESCRIP'TlON OWNERSHIP CEATIACATE at lS'•'l Olt Nl:."11" ff (MO) ,t:jj(-"'!'._� «�t Cit lli!rDIIICCJOl»IO(Ol••fltl'Oll1 a:u ICI SAiD tl.lO!I DI! '1'11Clf.SI • K Cd. 11'.�0 1$. W.�IC • ,.,,...�1.tU:..•C.OU-OIMOlllTil-lfl«w�.UJO �;:;;;�� M � .. .-��O l•� •JJIII. LOT STATISTICS ,w;1;Jll'>JMIC"IH:/�IT...::Mo.D o::,,;oo,,...s/"1 ..... U!,11'$ SIEETNlEX *ll l(Wl,t.l"(IR,l,Cl..,V,/11«,/�1[1,/-T'f""''lil�/�IAl!!.-S:.W.W-/<IC,,.(II� IKfl? �•�1UTIII\M< -·M$l.1,,(.. •�-IJl"U�co,.,,., /IDlwS-'$."liUll�O.._ """"'� Jfr..&,.'Ol-� ... ou.-a.t:ilOI ;M)or, l-"D ��S5.IOl•IW90fla.•. GENERAL NOTES �ctli':0:(1:() J -,IHltJU!I -ltUSI ., ... .,,lll�l'I.WOllS 11(1,ot(tWl�u'j(I, �!11-,..)1)--W'!"Klill: � ISIS:IIU'I OSI tUlJ'O.Oll'J,,\-.UI l(J'l-,Oa<-bll.('V/111!) ._ Q:lt:MlllNl\lll ..:i,C{NSl..,."W._,,UI s fASIM: ZO..C· Sl'(tlflC "'-"" tlP1) o. ,_,,n l(MIC: war;,,_ .. t-,,J I l.tC-'D"Cl�-�OiYSO.K"'tlU-•t!SCoiw->""1"" IL1'httw::oi.�l,.O(�"U-IV(tl)� • fio\$�Olu.ll�lY'i0,PMiNIICOU"�C.O.SCC.W••u I. 1(\.t'l'H(N'.9"a,,,c(•1•""1COIS'ISI'(""-" ICl(.talli�,-.i.ll"l!O'«olll'ill'l:C-'1 =:'!.:'�lllCI.MQ•J(il',..9"...,lil<"'211UaJIIOIU>tT"-onr;1 11 : :-:.:�::O�"::uu,tlll,� \DIIO"-IOI � 11! fOIIH • UU ll lltS.OIIOL('ldl«.<n■r1C1r:D11W"Y .... r;i,,V...r011J,-('.ft(;-.CDf'lt.ll,/Ol/10Dl "-SC'oQf.\C:tllH· S"..o./101,.00..CCW(tllllt,$,of.115.,_;:,r,t1$� -.i a M -•'II M: Oh' d S.,,,\• -'$ $1-C-"'ll 51'((7'1;.•1'?'-S t(lt 1,,( ,:o,,s--,c.,_ (.I •·•Ill,. 'l[_, -•c.-:D UU f.t<ll. IU t5, :n��'�..C:::<��;:,,c:-:,;��IIG .. IP �CIIUIMI, f(llt N et.s.'1111:� go ... � '!llll('I 11Q lll(Q>IIU .,:{I fllClflU 1f :.ei�CfO'�SM-'101U-.JIIPl.f,_IW'$fl.llM$1(111•Mf !J oL,Jl1:IWIU 'S .._, � (�� #OJ-"!'S-.,_. 1lr[ 111-IJTd • ,0.:,()tlhtll'S�-.-..C:..:LM;'f,lll-·O,IIYfi$10'1,C..,, ,,,_, "'° Q#;Lt!HP,-':(11/1/Q. 5l,lJlWl'I' -S MU f/.ll ot:TJUO lllll,_ •• �MllCilldN�n:,llo01"""$'1'$&•--N!MtSdWSl'fW)LI:' -•,....•1t11�M4;-1..C,ITl10o(��-\OII It �fJf-""'1JC'_, •• Cl),,,.ll,)ff..--r.T•S--�l.-ctlG$Nrr;r,T �,n.-; WSOF�- - ""'fi Ila',,_«•-$ 'i. l.lf51"'--.. u ... ali"...:'t(O,lllt�Hllll■f;ll.0:0t1Pl,.;,[ �. :C��il(I� « 10 - "-Q.l:ID<T1no,,c �os ..... u '1. IO'II ..O•ll.tl'UOl��O. ,n_,,,..,.Cr.0:�0,,lWf-Ol#i tl�-19\! lO'SfOII ....... r-, oo.t.RJC-,_,Cllaolllll P'IH'QI.$ :::r: ,';'f;f g� = ..,_,,-..., U:� IQ:,; NO. 1!1:0,1111(0 f� n P1110111011t:•�-••,M)-�'tl(�., .... -• 'Wlt;l(:M:"rw,,,.n;t,i•JO-W.:r.:i,-,r.-11.ca»111� 1i.1,IVli _.J,Q.l,ll;ll11o(!llll.CBOS-O,.Hll'f'ICIJ,'l.lll,t lllo('IIU#{'Vll'lj 1'11Sl'Uio-.,_Nllltl''-'Sllltt�(WIH'!llCID6),f•irU#ill0C..ll:)o$k.r.( =�:=1�fM l,C._,,.t lf<e..,.GUS l'4"1.l-OIIJL.IIS•t■� n.soo:,o,cis..:1�u.tU•�U<if'(O :IOI IIUSQ.«.('!.0Jllllll(lt,fb6.W)PL)(S-Cll:O!Si>IG$-,St.;1M:tUl•..::, -- 0ISle. 11H ACl l(�oln a. SIUl llll! ft:"°""' •Mo II,(� 11011•�•""' \ ....:;, 1D - t'I W:O,-,OIOI.H0-1U(l!��U(l.lot} •U:"IO l!t.CU.11"" H lll.lo(l',"-OI l«o1'1(;$111UTM:(($)-l((tf\Jtl•l,i-Ml(l'O'iUJ �'1..illll'l!QIU010WOTrCfWIJ.,.,.,,rotOll:1'0'H:I\'"' 21 �i:�;;tt;::s:�1:.=�t:..�'-"�-S/XhlCO,.» 111!9"_-QjW�Sl'lt:"-"'ll';lr;lolT"IIIL)OI.N..iYOlllllll.lll l(-0011�.UliASlt:«SSW,�COW,U-/XK«:Mt-10lK �� :_ :::t �.:._ � �,-.i.m ,u,,,-... Exhibit B to Exhibit 2 t �·�, I"",.,.., . v�!r.n� -��' 0 � a: � w rffll gi a: :r: ,z �-:/1 •· .. v i''" v&.:· .. u I I I ,.I I;:, I I I I I II oor...s:s_.., -l!Mo..l.l)fOI ..0,'10.<S5t-.f "�Cllr\� I♦ 1\101',�=/'oe.::� •' ! �:Ill�·� j $ .. 1...,s--.g-, .' I' ,., , , I ________________ J __ _ ""'��1:':11 f 1ST STREET .• 1 ,,::-,:,;u '-ll.��+::----��"--� ��-�--------- w.llll) -----a·,o•IUII I I • ,. I ------�-...,1t .. 111i;l(01IXo.lfDIOOT> NOTE __ _ "".��= r�=-�•NU , ..,..-,:.;,� � �1::1"�:;_ :�i o(��1 .. I �---�=------.-,,==-----.-�--�==-------r----,----,----,--------------.---=---l' �=--... ,... .. AS s .... --�--PRELIMINARY UTILITY PLAN ¥ / I ;::, A IM IO r:;" ·-""'""' TENTATIVE TRACT MAP NO. 19274 � N»MS mlfml 101 NORTH HARBOR BOULEVARD TTM 2 � fv<"� '1"1 •�'"•••• ��8::'•�.e. sun .. • L-CC"------' CITYOfSANTAAAA.COUNTYOfOAANGE, -g_ -� l,is..:t Pl'-11m•2021 eoomttn -11>.t:�""' STATEOFCAl.tFORNIA Exhibit B to Exhibit 2 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 9 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) 5.2 AIR QUALITY 2-1 Applicants for new development projects within the Harbor Boulevard Mixed Use Transit Corridor Plan shall require the construction contractor to use equipment that meets the United States Environmental Protection Agency (EPA)-Certified emissions standards according to the following schedule. •From the end of 2011 to December 31, 2014, all project-relatedoff-road diesel-powered construction equipment greater than 50horsepower shall meet Tier 3 off-road emissions standards. Anyemissions control device used by the contractor shall achieveemissions reductions that are no less than what could beachieved by a Level 3 diesel emissions control strategy for asimilarly sized engine, as defined by CARB regulations. •After January 1, 2015, all off-road diesel-powered constructionequipment greater than 50 horsepower shall meet the Tier 4Final emission standards. Any emissions control device used bythe contractor shall achieve emissions reductions that are noless than what could be achieved by a Level 4 diesel emissionscontrol strategy for a similarly sized engine, as defined by CARBregulations. Prior to construction, the project engineer shall ensure that all demolition and grading plans clearly show the requirement for EPA Tier 3 or higher emissions standards for construction equipment over 50 horsepower. During construction, the construction contractor shall maintain a list of all operating equipment in use on the project site for verification by the Building Safety Division. The construction equipment list shall state the makes, models, and numbers of construction equipment onsite. Equipment shall properly service and maintain construction equipment in accordance with the manufacturer’s recommendations. Construction contractors shall also ensure that all nonessential idling of construction equipment is restricted to five minutes or less in compliance with California Air Project applicant Prior to grading permits; on-going monitoring during construction Planning and Building Agency, Building Safety Division Exhibit C to Exhibit 2 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements Page 10 PlaceWorks Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) Resources Board’s Rule 2449. 2-2 Applicants for new development projects within the Harbor Boulevard Mixed Use Transit Corridor Plan shall require the construction contractor to prepare a dust control plan and implement the following measures during ground-disturbing activities in addition to the existing requirements for fugitive dust control under South Coast Air Quality Management District Rule 403 to further reduce PM10 and PM2.5 emissions. The Building Safety Division shall verify compliance that these measures have been implemented during normal construction site inspections. • Following all grading activities, the construction contractor shall reestablish ground cover on the construction site through seeding and watering. • During all construction activities, the construction contractor shall sweep streets with Rule 1186–compliant, PM10-efficient vacuum units on a daily basis if silt is carried over to adjacent public thoroughfares or occurs as a result of hauling. • During all construction activities, the construction contractor shall maintain a minimum 24-inch freeboard on trucks hauling dirt, sand, soil, or other loose materials and tarp materials with a fabric cover or other cover that achieves the same amount of protection. • During all construction activities, the construction contractor shall water exposed ground surfaces and disturbed areas a minimum of every three hours on the construction site and a minimum of three times per day. • During all construction activities, the construction contractor shall limit onsite vehicle speeds on unpaved roads to no more than 15 miles per hour. Project applicant Prior to grading permits; on-going monitoring during construction Planning and Building Agency, Building Safety Division 2-3 Applicants for new development projects within the Harbor Boulevard Mixed Use Transit Corridor Plan shall require the construction contractor to use coatings and solvents with a volatile organic Project applicant Prior to building permits; on-going monitoring during construction Planning and Building Agency, Building Safety Division Exhibit C to Exhibit 2 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 11 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) compound (VOC) content lower than required under Rule 1113 (i.e., super compliant paints). All architectural coatings shall be applied either by (1) using a high-volume, low-pressure spray method operated at an air pressure between 0.1 and 10 pounds per square inch gauge to achieve a 65 percent application efficiency; or (2) manual application using a paintbrush, hand-roller, trowel, spatula, dauber, rag, or sponge, to achieve a 100 percent applicant efficiency. The construction contractor shall also use precoated/natural colored building materials, where feasible. Use of low-VOC paints and spray method shall be included as a note on architectural building plans and verified by the Building Safety Division during construction. 2-4 Applicants of residential developments which are designed to include shared community barbeques shall only install electric powered barbeque units. These units shall be specified on site and building plans and shall be verified by the Building Safety Division prior to issuance of a Certificate of Occupancy. Project applicant Prior to issuance of certificate of occupancy Planning and Building Agency, Building Safety Division 2-5 Applicant-provided appliances shall be Energy Star appliances (dishwashers, refrigerators, clothes washers, and dryers). Installation of Energy Star appliances shall be verified by the Building Safety Division during plan check. Project applicant Prior to issuance of certificate of occupancy Planning and Building Agency, Building Safety Division 2-6 Applicants of residential developments which include garage and/or car port parking shall ensure that garage and/or car port parking are electrically wired to accommodate a Level 2 (240 volt) electric vehicle charging outlet per dwelling unit. The location of the electrical outlets shall be specified on building plans and proper installation shall be verified by the Building Safety Division prior to issuance of a Certificate of Occupancy. Project applicant Prior to issuance of certificate of occupancy Planning and Building Agency, Building Safety Division 2-7 Applicants of retail, commercial, office, and other non-residential development shall provide Level 2 vehicle charging stations for public use and where feasible, coordinate with the City of Santa Ana to install Level 3 (480 volt or higher) charging stations. The location of the charging station(s) shall be specified on site and building plans Project applicant Prior to issuance of certificate of occupancy Planning and Building Agency, Building Safety Division Exhibit C to Exhibit 2 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements Page 12 PlaceWorks Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) and proper installation shall be verified by the Building Safety Division prior to issuance of a Certificate of Occupancy. 2-8 Applicants for non-residential projects within the Harbor Boulevard Mixed Use Transit Corridor Plan, that employ 20 or more people—which is equivalent to 16,000 square feet of retail space or 10,000 square feet of office space—shall implement an employee commute trip reduction (CTR) program. The CTR program shall identify alternative modes of transportation to the project, including transit schedules, bike and pedestrian routes, and carpool/vanpool availability. Information regarding these programs shall be readily available to employees and clients. The project applicant or designee shall consider the following incentives for commuters as part of the CTR program: • Rideshare matching assistance through OCTA • Subsidized public transit passes • Vanpool assistance • Car or bike-sharing program • Bicycle end-trip support facilities such as bike storage or lockers. Project applicant Prior to issuance of certificate of occupancy Planning and Building Agency, Planning Division 2-9 Applicants of commercial, office, retail, and other non-residential development within the specific plan area shall provide the following features to reduce project-related mobile-source air pollutant emissions: • Preferential parking for carpools and vanpools. • Preferential parking for alternative-fuel vehicles (e.g., compressed natural gas or hydrogen). • Secure bicycle parking and storage facilities for visitors. • Commuter information boards identifying bicycle paths and public transit routes and schedules. Project applicant Prior to issuance of building permit Planning and Building Agency, Planning Division 2-10 Applicants for residential or residential mixed-use projects within: 1) 1,000 feet from the truck bays of an existing distribution centers that accommodate more than 100 trucks per day, more than 40 trucks with Project applicant Prepare HRA prior to approval of any future discretionary residential or Planning and Building Agency, Building Safety Division, Zoning Exhibit C to Exhibit 2 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 13 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) operating transport refrigeration units, or where transport refrigeration unit operations exceed 300 hours per week; or 2) 1,000 feet of an SCAQMD permitted facility, or an industrial facility which emits toxic air contaminants shall submit a health risk assessment (HRA) prepared in accordance with policies and procedures of the state Office of Environmental Health Hazard Assessment (OEHHA) and the South Coast Air Quality Management District (SCAQMD). The HRA shall be submitted to the Zoning Administrator prior to approval of any future discretionary residential or residential mixed-use project. If the HRA shows that the incremental cancer risk exceeds one in one hundred thousand (1.0E-05), PM concentrations would exceed 2.5 μg/m3, or the appropriate noncancer hazard index exceeds 1.0, the HRA shall identify the level of high-efficiency Minimum Efficiency Reporting Value (MERV) filter required to reduce indoor air concentrations of pollutants to achieve the cancer and/or noncancer threshold. The Applicant shall be required to install high efficiency MERV filters in the intake of residential ventilation systems, consistent with the recommendations of the HRA. Heating, air conditioning and ventilation (HVAC) systems shall be installed with a fan unit power designed to force air through the MERV filter. To ensure long-term maintenance and replacement of the MERV filters in the individual units, the following shall occur: • Developer, sale, and/or rental representative shall provide notification to all affected tenants/residents of the potential health risk for affected units. • For rental units, the owner/property manager shall maintain and replace MERV filters in accordance with the manufacture’s recommendations. The property owner shall inform renters of increased risk of exposure to diesel particulates when windows are open. • For residential owned units, the Homeowner’s Association (HOA) shall incorporate requirements for long-term maintenance residential mixed-use project; Installation of MERV filter requirements and maintenance prior to issuance of building permits Administrator Exhibit C to Exhibit 2 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements Page 14 PlaceWorks Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) in the Covenant Conditions and Restrictions and inform homeowners of their responsibility to maintain the MERV filter in accordance with the manufacturer’s recommendations. The HOA shall inform homeowners of increased risk of exposure to diesel particulates when windows are open. 5.3 CULTURAL RESOURCES 3-1 Prior to the issuance of grading permits, and for any subsequent permit involving excavation to increased depth, the project applicant for each development or redevelopment project considered for approval pursuant to the Harbor Boulevard Mixed Use Transit Corridor Plan shall provide letters to the City of Santa Ana from a qualified archaeologist and paleontologist (for excavations six feet below ground surface and deeper) who meet the Secretary of the Interior’s Professional Qualifications Standards. The letters shall state that the project applicant has retained these individuals, and that the consultant(s) will be on call during all grading and other significant ground-disturbing activities. In the event archeological or paleontological resources are discovered during ground-disturbing activities, the professional archeological or paleontological monitor shall have the authority to halt any activities adversely impacting potentially significant cultural resources until they can be formally evaluated. Suspension of ground disturbances in the vicinity of the discoveries shall not be lifted until the archaeological or paleontological monitor, in coordination with the construction contractor, has evaluated discoveries to assess whether they are significant cultural resources, pursuant to the California Environmental Quality Act (CEQA). If significance criteria are met, then the project shall be required to perform data recovery, professional identification, radiocarbon dates as applicable, and other special studies; they shall be offered for curation or preservation to a repository with a retrievable collection system and an educational and research interest in the materials, such as the Los Angeles County Museum of Natural History or California State University, Fullerton, or other local museum or repository. If no museum or repository is willing to accept the Project applicant Prior to issuance of grading permit Planning and Building Agency, Planning Division Exhibit C to Exhibit 2 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 15 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) resource, the resource shall be considered the property of the City, and may be stored, disposed of, transferred, exchanged, or otherwise handled by the City at its discretion. 5.6 HAZARDS AND HAZARDOUS MATERIALS 6-1 Prior to the issuance of demolition permits for any buildings or structures that would be demolished in conjunction with individual development projects that would be accommodated by the Harbor Boulevard Mixed Use Transit Corridor, the project applicant shall conduct the following inspections and assessments for all buildings and structures onsite and shall provide the City of Santa Ana’s Planning and Building Agency with a copy of the report of each investigation or assessment. • The project applicant shall retain a certified lead inspector/assessor to inspect buildings and structures onsite for lead-based paint (LBP). The inspector/assessor’s report shall include requirements for abatement, containment, and disposal of LBP, if encountered, in accordance with the State of California Occupational Safety & Health Administration Rule 29 CFR Part 1926. • The project applicant shall retain a licensed or certified asbestos consultant to inspect buildings and structures onsite for asbestos-containing materials (ACM). The consultant’s report shall include requirements for abatement, containment, and disposal of ACM, if encountered, in accordance with the South Coast Air Quality Management District’s Rule 1403. Project applicant Prior to issuance of demolition permit Planning and Building Agency, Building Safety Division 6-2 Prior to the issuance of grading permits for new development within the Harbor Boulevard Mixed Use Transit Corridor, the project applicant shall submit a Phase I Environmental Site Assessment (ESA) to identify environmental conditions and determine whether contamination is present. The Phase I ESA shall be prepared by a Registered Professional Engineer and in accordance with the American Society for Testing and Materials (ASTM) Standard E Project applicant Submit Phase I ESA prior to issuance of grading permit; Submit remediation documentation prior to issuance of building permit, if needed Building Official Exhibit C to Exhibit 2 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements Page 16 PlaceWorks Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) 1527.05, Standard Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process. If recognized environmental conditions related to soils are identified in the Phase I ESA, the project applicant shall perform soil sampling as a part of a Phase II ESA. If contamination is found at significant levels, the project applicant shall remediate all contaminated soils in accordance with state and local agency requirements (DTSC, RWQCB, Orange County Fire Authority, etc.). All contaminated soils and/or material encountered shall be disposed of at a regulated site and in accordance with applicable laws and regulations prior to the completion of grading. Prior to the issuance of building permits, a report documenting the completion, results, and any follow-up remediation on the recommendations, if any, shall be provided to the Building Official and the City of Santa Ana’s Planning and Building Agency evidencing that all site remediation activities have been completed. 5.7 HYDROLOGY AND WATER QUALITY 7-1 Prior to issuance of grading permits for future development projects in the Harbor Corridor Plan, applicants shall submit site-specific hydrology and hydraulic Studies to the Public Works Agency for review and approval. If existing facilities are not adequate to handle runoff generated by the proposed development, then the applicant shall construct storm drain improvements. Storm drain upgrades shall be implemented prior to issuance of occupancy permits. Project applicant Prior to issuance of grading permit Public Works Agency 7-2 During the design of individual projects, applicants shall minimize impervious area by incorporating landscaped areas over substantial portions of a proposed project area. Furthermore, impervious areas shall be directly connected to landscaped areas or bioretention facilities to promote filtration and infiltration of stormwater. The applicant must comply with the latest Orange County Model Water Quality Management Plan (WQMP). Project applicant Prior to issuance of grading permit Public Works Agency 7-3 Notice of Intent (NOI). Prior to the issuance of a grading permit for Project applicant Prior to issuance of grading Public Works Agency; City Exhibit C to Exhibit 2 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 17 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) construction sites with a disturbed area of one or more acres, the project applicant shall provide the City Engineer with evidence that a NOI has been filed with the State Water Resources Control Board. Such evidence shall consist of a copy of the NOI stamped by the State Water Resources Control Board or Regional Water Quality Control Board, or a letter from either agency stating that the NOI has been filed. permit Engineer 7-4 Storm Water Pollution Prevention Plan (SWPPP). Prior to the issuance of grading permits for construction sites with a disturbed area of one or more acres, the project applicant shall prepare a SWPPP that will: • Require implementation of best management practices (BMPs) designed with a goal of preventing a net increase in sediment load in stormwater discharges relative to preconstruction levels; • During the construction period, prohibit discharges of stormwater or non-storm water at levels which would cause or contribute to an exceedance of applicable water quality standards contained in the Basin Plan; • Discuss in detail the BMPs planned for the project related to control of sediment and erosion, nonsediment pollutants, and potential pollutants in non-storm water discharges; • Describe post-construction BMPs for the project; • Explain the maintenance program for the project’s BMPs; • During construction, require reporting of violations to the Regional Board; • List the parties responsible for SWPPP implementation and BMP maintenance during and after grading. The project proponent shall implement the SWPPP and will modify the SWPPP as directed by the Storm Water Permit. Project applicant Prior to issuance of grading permit Public Works Agency; City Engineer 7-5 Water Quality Management Plan (WQMP). Prior to the issuance of precise grading permits, project-specific WQMPs shall be submitted for review and approved by the Public Works Agency. The WQMP Project applicant Prior to issuance of precise grading permits Property Owner Exhibit C to Exhibit 2 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements Page 18 PlaceWorks Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) shall identify the best management practices (BMPs) that will be used on the site to control predictable pollutant runoff. More specifically, the WQMP shall: • Describe the routine and special post-construction BMPs to be used at the proposed development site (including both structural and non-structural measures); • Describe responsibility for the initial implementation and long-term maintenance of the BMPs; • Provide narrative with the graphic materials as necessary to specify the locations of the structural BMPs; • Certify that the project applicant will seek to have the WQMP carried out by all future successors or assigns to the property. • The applicant must comply with the latest Orange County Model Water Quality Management Plan (WQMP). 7-6 Prior to the issuance of precise grading permit for any lot or parcel wholly or partially located within the 100-year floodplain, the applicant shall furnish to the Building Official documentation required by FEMA for approval of the Conditional Letter of Map Revision/Letter of Map Revision (CLOMR/LOMR) process. The FEMA for revision to the FIRM and Flood Insurance Study (FIS). The applicant shall pay all preliminary and subsequent fees as required by FEMA. Project applicant Prior to issuance of precise grading permit Building Official 5.9 NOISE 9-1 Prior to issuance of a building permit, applicants for new residential development in the Harbor Corridor Plan shall submit an acoustic report prepared to the satisfaction of the Building Official or their designee to ensure that noise levels at outdoor living areas such as private yards, balconies, and park picnic areas shall not exceed 65 dBA CNEL, and all residential habitable rooms would meet the 45 dBA CNEL interior noise standard. These noise studies would need to be submitted after the precise grading and architectural plans are prepared, but prior to issuance of building permits. The required Project applicant Prior to issuance of building permit Planning and Building Agency, Building Safety Division Exhibit C to Exhibit 2 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 19 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) exterior noise reduction can be accomplished with sound walls or berms, or by site plan/building layout design. The required interior noise reduction can be accomplished with enhanced construction design or materials such as upgraded dual-glazed windows and/or upgraded exterior wall assemblies. These features shall be shown on all building plans and incorporated into construction of the project. City inspectors shall verify compliance of the building with the acoustic report’s recommendations prior to issuance of a Certificate of Occupancy. 9-2 Prior to issuance of a building permit, applicants for new commercial, office, or retail developments in the Harbor Corridor Plan shall submit an acoustic report prepared to the satisfaction of the Zoning Administrator and Building Official or their designee to ensure that the operation of stationary noise sources (i.e., HVAC units, truck deliveries) would not cause a noise increase of more than 5 dBA over the ambient noise levels at any adjacent property. These noise studies would need to be submitted after the precise grading and architectural plans are prepared, but prior to issuance of building permits. This requirement can be accomplished with selection of quieter equipment, judicious site layouts and equipment positioning, and/or equipment enclosures, sound screening, or parapet walls. These features shall be shown on all building plans and incorporated into the construction of the project. City inspectors shall verify compliance of the building with the acoustic report’s recommendations prior to issuance of a Certificate of Occupancy. Project applicant Prior to issuance of building permit; prior to issuance of certificate of occupancy Planning and Building Agency, Zoning Administrator and Building Official or designee 9-3 Prior to issuance of a building permit, applicants for projects within the Harbor Corridor Plan that involve high-vibration construction activities, such as pile driving or vibratory rolling/compacting, shall be evaluated for potential vibration impacts to nearby sensitive receptors. The project developer shall submit a vibration report prepared to the satisfaction of the City of Santa Ana Building Official or their designee to determine if the use of pile driving and/or vibratory rolling/compacting equipment would exceed the Federal Transit Project applicant Prior to issuance of building permit Planning and Building Agency, Building Official or designee Exhibit C to Exhibit 2 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements Page 20 PlaceWorks Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) Administration’s (FTA’s) vibration-annoyance criteria of 78 VdB during the daytime or FTA’s vibration-induced architectural damage PPV criteria of 0.2 inches/second for wood-framed structures or 0.5 inches/second for reinforced masonry buildings. The construction contractor shall require the use of lower-vibration-producing equipment and techniques. Examples of lower-vibration equipment and techniques would include avoiding the use of vibratory rollers near sensitive areas and/or the use of drilled piles, sonic pile driving, or vibratory pile driving (as opposed to impact pile driving). 9-4 Prior to issuance of grading permits, the project applicant shall ensure the following notes are included on the grading plan cover sheet, and the construction contractor shall comply with these measures during the duration of all construction activities. • Properly maintain and tune all construction equipment to minimize noise. • Fit all equipment with properly operating mufflers, air intake silencers, and engine shrouds, no less effective than as originally equipped by the manufacturer, to minimize noise emissions. • Locate all stationary noise sources (e.g., generators, compressors, staging areas) as far from noise-sensitive receptors as possible. Material delivery, soil haul trucks, and equipment servicing shall be restricted to the hours between 7:00 AM and 8:00 PM Mondays through Saturdays, and not at all on Sundays or federal holidays. Project applicant Prior to issuance of grading permit Planning and Building Agency, Planning Division 9-5 Prior to the issuance of grading permits, each project applicant within the project area shall prepare a construction management plan that shall be approved by the City of Santa Ana Public Works. The construction management plan shall: • Establish truck haul routes on the appropriate transportation facilities. Truck routes that avoid congested streets and sensitive land uses shall be considered. Project applicant Prior to issuance of grading permit Public Works Agency Exhibit C to Exhibit 2 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 21 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) • Provide Traffic Control Plans (for detours and temporary road closures) that meet the minimum City criteria. Traffic control plans shall determine if dedicated turn lanes for movement of construction truck and equipment on- and offsite are available. • Minimize offsite road closures during the peak hours. • Keep all construction-related traffic onsite at all times. • Provide temporary traffic controls, such as a flag person, during all phases of construction to maintain smooth traffic flow. 5.13 TRANSPORTATION AND CIRCULATION 13-1 Prior to the issuance of building permits, the project applicant shall evaluate the potential for any neighborhood cut through traffic. Neighborhood cut through traffic shall be minimized through implementation of traffic calming measures as approved by the Public Works Agency. Project applicant Prior to the issuance of building permit Public Works Agency 13-2 The City of Santa Ana shall implement a program for traffic improvements in the Harbor Corridor Plan. The program shall prescribe the method of participation in the mitigation program by individual projects and guide the timely implementation of mitigation measures. The program shall include the following elements: • A funding and improvement program should be established to identify financial resources adequate to construct all identified mitigation measures in a timely basis. • All properties that redevelop within the Harbor Corridor Plan should participate in the program on a fair share per new development trip basis. The fair share shall be based upon the total cost of all identified mitigation measures (see Mitigation Measure 13-3), divided by the peak hour trip generation increase forecast. This rate per peak hour trip should be imposed upon the incremental traffic growth for any new development within the Harbor Corridor Plan. • The project shall raise fund from full development of the Harbor City of Santa Ana On-going monitoring Public Works Agency Exhibit C to Exhibit 2 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements Page 22 PlaceWorks Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) Corridor Plan to fund all identified mitigation measures. • The project shall monitor phasing development of the Harbor Corridor Plan and defer or eliminate improvements if the densities permitted in the Harbor Corridor Plan are not occurring. • Program phasing shall be monitored through preparation of specific project traffic studies for any project that is expected to include more than 100 dwelling units or 100,000 sf of non-residential development. Traffic impact studies should use traffic generation rates that are deemed to be most appropriate for the actual development proposed. • The City may elect to implement appropriate mitigation measures as a condition of approval of the proposed developments, where appropriate. All or part of the costs of these improvements may be considered to be a negotiated credit toward the program, however the program must be administered in a manner that assures that it can fund necessary improvements to maintain adequate level of service at all intersections within the study. If funding of priority improvements cannot be assured, credit for construction of lower priority improvements may not be assured or may be postponed until more program funds are available. 13-3 Prior to the issuance of building permits, the project applicant shall participate in the program for traffic improvements in the Harbor Corridor Plan per MM 13-2. The traffic improvement program includes the following improvements: • Intersection #26: Fairview Street and 17th Street (Year 2035) o Improvements are to add a northbound through lane. • Intersection #27: Fairview Street and 1st Street (Year 2035) o Improvements are to add a southbound right-turn lane. Project applicant Prior to issuance of building permit Public Works Agency 5.14 UTILITIES AND SERVICE SYSTEMS 7-1 Mitigation Measure 7-1 applies. See Hydrology and Water Quality section, above. Exhibit C to Exhibit 2 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 23 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) 14-1 Prior to the first building permit pursuant to the proposed project, the City of Santa Ana shall prepare a “Nexus” Study that will serve as the basis for requiring development impact fees under AB 1600 legislation, as codified by California Code Government Section 66000 et seq. The established procedures under AB 1600 require that a “reasonable relationship” or nexus exist between the water and sewer infrastructure improvements and facilities required to mitigate the sewer impacts of new development pursuant to the proposed project. The sewer segment improvements shown on Table 5.14-11 of the DEIR are necessary to mitigate project impacts and shall be included, among other improvements, in the AB 1600 nexus study. City of Santa Ana Prior to issuance of first building permit Public Works Agency 14-2 Prior to the issuance of the first building permit pursuant to the proposed project, the City of Santa Ana shall prepare a Development Fee program pursuant to the AB 1600 Nexus Study identified in Mitigation Measure 14-1, above. The Development Fee program would fund the Harbor Corridor Plan area-wide water and sewer infrastructure improvements. The fee program shall stipulate that fees are assessed when there is new construction or when there is an increase in square footage within an existing building or the conversion of existing square footage to a more intensive use. Fees are calculated by multiplying the proposed square footage or dwelling unit by the rate identified. The fees are included with any other applicable fees payable at the time the building permit is issued. The City will use the development fees to fund construction (or to recoup fees advanced to fund construction) of the infrastructure improvements identified in Mitigation Measure 14-1. City of Santa Ana Prior to issuance of first building permit Public Works Agency 14-3 Prior to the issuance of a grading permit, the project applicant shall prepare water and sewer studies and identify the sizing and location of backbone facilities necessary to serve the proposed project, in accordance with City standards. The water and sewer plans shall be submitted to the City’s Public Works Agency for review and approval. Design of facilities that serve the project shall be sufficient to meet the projected service demands. Project applicant Prior to issuance of a grading permit Public Works Agency Exhibit C to Exhibit 2 Prepared by: Megan A. Lam Transportation Engineer Ill TRAFFIC AND PARKING ANALYSIS FIRST HARBOR MIXED-USE PROJECT Santa Ana, California October 23, 2023 Prepared for: HARBOR & FIRST, LLC 750 N. Diamond Bar Boulevard, Suite 101 Diamond Bar, CA 91765 LLG Ref. 2.23.4737.1 Under the Supervision of: Trissa de Jesus Allen, P.E., RSP Senior Transportation Engineer LINSCOTT LAW & GREENSPAN engineers Linscott. law& Greenspan. Engineers 2 Executive Circle Suite 2.50 lrvme.CA9Z614 949.825.6175 T 9QS.825.6l73 F w1Mv.llgeng,neers.com Exhibit D to Exhibit 2 TABLE OF CONTENTS SECTION PAGE 1.0 Introduction ................................................................................................................................. 1 I.I Scope ofWork ...................................................................................................................... l 1.2 Study Area ............................................................................................................................ 2 2.0 Project Description ..................................................................................................................... 3 2.1 Site Access ............................................................................................................................ 3 2.2 Pedestrian and Bicycle Circulation ....................................................................................... 3 3.0 Existing (2023) Conditions ......................................................................................................... 4 3. I Existing Street System .......................................................................................................... 4 3.2 Existing Traffic Volumes ...................................................................................................... 4 3.3 Existing Public Transportation ............................................................................................. 5 3.4 Existing Intersection Conditions ........................................................................................... 6 3.4.1 Intersection Capacity Utilization (ICU) Method of Analysis ..................................... 6 3.4.2 Highway Capacity Manual (HCM) Method of Analysis (Unsignalized Intersections) ....................................................................................... 6 3.4.3 Level of Service Criteria ............................................................................................. 9 3 .5 Existing Level of Service Results ......................................................................................... 9 4.0 Traffic Forecasts ....................................................................................................................... 11 4.1 Project Traffic Generation .................................................................................................. 12 4.2 Project Traffic Distribution and Assignment.. .................................................................... 12 4.3 Existing Plus Project Traffic Volumes ............................................................................... 14 4.4 Year2028 Cumulative Base ............................................................................................... 14 4.4.1 Ambient Traffic Growth ........................................................................................... 14 4.4.2 Cumulative Projects .................................................................................................. 14 4.4.3 Year 2028 Cumulative Base Traffic Volumes .......................................................... 17 4.4.4 Year 2028 Cumulative Plus Project Traffic Volumes .............................................. 17 5.0 Non-CEQA Traffic Analysis .................................................................................................... 18 5.1 LOS Standards and Thresholds ........................................................................................... 18 5 .2 Traffic Analysis Scenarios .................................................................................................. 18 5.3 Existing (2023) Plus Project Traffic Conditions ................................................................. 19 5 .4 Year 2028 Traffic Conditions ............................................................................................. 21 5.4.1 Year 2028 Cumulative Base Traffic Conditions ....................................................... 21 5.4.2 Year 2028 Cumulative Plus Project Conditions ....................................................... 21 6.0 Site Access and Internal Circulati6n Evaluation ................................................................... 23 6.1 Site Access .......................................................................................................................... 23 6.1.1 Traffic Gap Assessment ............................................................................................ 25 6.2 Internal Circulation Evaluation ........................................................................................... 28 6.3 Sight Distance Evaluation ................................................................................................... 28 LINSCOTT, LAW & GREENSPAN, engineers LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N· ·.+70(11:Z:ZH7J7. F,r,t H:i,bor ;\,l11.ed t:s�. S:111ta Ana'R,:po,rl47J7 F11-s1 lfarbor �lu;�d-Us�, Santa ,-\na Traffic Stl1dy 10-2J-2J doc Exhibit D to Exhibit 2 TABLE OF CONTENTS (CONTINUED) SECTION PAGE 7.0 Intersection Turn Pocket Queuing Analysis ........................................................................... 30 8.0 Congestion Management Program (CMP) Compliance Assessment ................................... 34 9.0 Roadway Segment Evaluation ................................................................................................. 35 9.1 Roadway Link Capacities ................................................................................................... 35 9.2 Roadway Link Level of Service Criteria ............................................................................ 35 9.3 Roadway Segment Analysis Results ................................................................................... 37 9.3.1 Existing Plus Project Analysis .................................................................................. 37 9.3.2 Year 2028 Plus Project Analysis ............................................................................... 39 10.0 CEQA Assessment ofVMT, Active Transportation, & Public Transit ............................... 41 IO.I Vehicle Miles Traveled (VMT) Screening Analysis .......................................................... 41 10.2 Active Transportation and Public Transit Screening Analysis ........................................... 41 11.0 Parking Analysis and Parking Management Plan (PMP) ..................................................... 43 1 I. 1 City Code Parking Requirements ........................................................................................ 43 11.2 Parking Management Plan (PMP) ...................................................................................... 43 11.3 PMP Measures .................................................................................................................... 45 12.0 Summary Of Findings And Conclusions ................................................................................ 48 LINSCOTT, LAW & GREENSPAN, engineers ii LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N·;.170{1111J--17J7 -Fu;t 1--farbor Mi"ed lls.:, S;J.11t;i Ana'R�porN7J7 first H:ubor �IJ>.�d-L'�. Santa Ana Traffie Study I0-2J-2J doc Exhibit D to Exhibit 2 APPENDIX A.Existing Traffic Count Data APPENDICES B.Intersection Level of Service Calculation WorksheetsC.Project Driveway Level of Service Calculation WorksheetsD.Queuing Calculation WorksheetsLINSCOTT, LAW & GREENSPAN, engineers iii LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit D to Exhibit 2 LIST OF FIGURES SECTION-FIGURE# FOLLOWING PAGE 1-1 Vicinity Map ..................................................................................................................... 2 2-1 Existing Site Aerial ........................................................................................................... 3 2-2 Proposed Site Plan ............................................................................................................ 3 3-1 Existing Roadway Conditions and Intersection Controls ............................................. .4 3-2 Existing AM Peak Hour Traffic Volumes ...................................................................... 5 3-3 Existing PM Peak Hour and Daily Traffic Volumes ..................................................... 5 4-1 Project Traffic Distribution Pattem ................................................................................ 13 4-2 AM Peak Hour Project Traffic Volumes ...................................................................... 13 4-3 PM Peak Hour and Daily Project Traffic Volumes ..................................................... 13 4-4 Existing Plus Project AM Peak Hour Traffic Volumes ............................................... 14 4-5 Existing Plus Project PM Peak Hour and Daily Traffic Volumes .............................. 14 4-6 Location of Cumulative Projects .................................................................................... 15 4-7 AM Peak Hour Cumulative Projects Traffic Volumes .................................................. 17 4-8 PM Peak Hour and Daily Cumulative Projects Traffic Volumes .................................. 17 4-9 Year 2028 AM Peak Hour Cumulative Base Traffic Volumes ................................... 17 4-10 Year 2028 PM Peak Hour and Daily Cumulative Base Traffic Volumes .................. 17 4-11 Year 2028 AM Peak Hour Cumulative Plus Project Traffic Volumes ....................... 17 4-12 Year 2028 PM Peak Hour and Daily Cumulative Plus Project Traffic Volumes ...... 17 6-1 Harbor Boulevard Sight Distance Analysis .................................................................. 29 6-2 Figueroa Street Sight Distance Analysis ...................................................................... 29 6-3 Figueroa Street at I st Street SBR Sight Distance Analysis ......................................... 29 6-4 Figueroa Street at 1st Street SBL Sight Distance Analysis .......................................... 29 10-1 Santa Ana Transit Priority Areas ................................................................................. .41 10-2 VMT/SP in Santa Ana as Compared to Orange County Average ............................. .41 10-3 Santa Ana Development Areas that Cannot Be Screened .......................................... .41 LINSCOTT, LAW & GREENSPAN, engineers iv LLG Re[ 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N \47D(J122J47J7 -first Harbor �{1>.cd ll�. Santa AnalR�µo, 114737 F11s1 H:ubor ;\.IJ><�d-U�. S'-'llta .\n:1. Tralli.c Study J().2J.2J.<loc Exhibit D to Exhibit 2 LIST OF TABLES SECTION-TABLE# PAGE 3-1 Level of Service Criteria For Signalized Intersections (ICU Methodology) ............... 7 3-2 Level of Service Criteria For Unsignalized Intersections (HCM Methodology) ......... 8 3-3 Existing Peak Hour Intersection Capacity Analysis ....................................................... 10 4-1 Project Traffic Generation Forecast. ............................................................................... 13 4-2 Location and Description of Cumulative Projects .......................................................... 15 4-3 Cumulative Projects Traffic Generation Forecast .......................................................... 16 5-1 Existing Plus Project Peak Hour Intersection Capacity Analysis .................................. 20 5-2 Year 2028 Peak Hour Intersection Capacity Analysis ................................................... 22 6-1 Project Driveway Peak Hour Intersection Capacity Analysis ....................................... 24 6-2 Right-Tum Out Vehicle Gap Analysis .......................................................................... 26 6-3 Left-Tum Out Vehicle Gap Analysis ............................................................................ 27 7-1 Existing Plus Project Queuing Analysis ........................................................................ 32 7-2 Year 2028 Cumulative Plus Project Queuing Analysis ................................................ 33 9-1 Roadway Segment Capacities and Level of Service Criteria ......................................... 36 9-2 Existing Plus Project Roadway Segment Level of Service Summary ........................... 38 9-3 Year2028 Cumulative Plus Project Roadway Segment Level of Service Summary .... 40 11-1 City Code Parking Requirements .................................................................................. .44 LINSCOTT, LAW & GREENSPAN, engineers V LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N:,-17001:234737. F,r�t H:t1bor ;..i,��d l!sc, S:mta ,\i,J'R�porN7J7 F11'."t !farMr \lv,�d-l'�. S:intJ .\n:t Traffic Stud) I0-2J-2J.doe Exhibit D to Exhibit 2 1.0 INTRODUCTION TRAFFIC AND PARKING ANALYSIS FIRST HARBOR MIXED-USE PROJECT Santa Ana, California October 23, 2023 This Traffic and Parking Analysis was conducted by Linscott, Law & Greenspan, Engineers (LLG) to determine and evaluate the potential traffic circulation and parking needs associated with the First Harbor Mixed-Use Project, which is the development of a nine-story building with 183 multifamily residential units (including studios, I-bedroom, 2-bedroom, and 3-bedroom units) and 15,182 square feet (SF) of retail on the ground floor, as proposed by Harbor & First, LLC. Of the 183 total units proposed, 15% (28 units) would be designated as low-income housing. The residential and retail uses would wrap around a four-level parking structure, consisting of two subterranean levels, one street/ground level, and a second above-ground level, and provide a total of 333 standard parking spaces. The Project site, which is currently vacant, is located on the north side of I st Street, between Harbor Boulevard and Figueroa Street, at IO I North Harbor Boulevard in the City of Santa Ana, California. The Project site exists within a Specific Plan district regulated by the Harbor Mixed Use Transit Corridor Plan; specifically, the South Transit Node District, which is comprised of the properties surrounding the Bravo Bus Rapid Transit (BRT) stations at Harbor Boulevard and 1st Street, and at Harbor Boulevard and McFadden Avenue. The South Transit Node generally anticipates three- to six-story buildings within the District, with the flexibility to allow IO stories, and has an emphasis on mixed-use development. Based on this, the Project, as proposed with nine stories and a mix of uses, is consistent with the land use plan for the South Transit Node District the Project site is located in. 1.1 Scope of Work Based on close coordination with City staff, and staying consistent with the City of Santa Ana Traffic Impact Study Guidelines (September 20 I 9), this report presents a non-CEQA transportation assessment, including an inventory of existing characteristics and traffic volumes during the AM and PM peak commute periods at key locations within the study area, forecasts of vehicular traffic anticipated to be generated by the Pr oject, evaluation of potential non-CEQA impacts of Project generated trips on the surrounding street system under Year 2028 conditions (i.e., the anticipated completion year for the Project), and site access and internal circulation analysis. As described in the City's traffic impact study guidelines, this report also provides a CEQA assessment (Project screening) of VMT, active transportation, and public transit. In addition, the last section of this report presents the parking analysis and Parking Management Plan (PMP) prepared for the Project. LINSCOTT, LAW & GREENSPAN, engineers 1 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana :,,: ,4700\2�H7J7-Fm;! H:ubor \11>.eJ Use. S:mt� Aoa'R�po•t1,1737 First 11:!rl>or Mi,.,ed-l'se, Sanu .\n:t Traffic Stud, 10-23-lJ do<" Exhibit D to Exhibit 2 1.2 Study Area Two (2) key study intersections and one (I) key roadway segment have been identified for evaluation. The two (2) intersections/one (I) roadway segment listed below provide regional and local access to the study area and define the extent of the boundaries for this traffic investigation. Kev Study Intersections 1.Harbor Boulevard at 5th Street (City of Santa Ana)2.Harbor Boulevard at I st Street (City of Santa Ana) Kev Roadway Segment A.Figueroa Street, between 5th Street and I st Street (City of Santa Ana) Figure 1-1 presents a Vicinity Map, which illustrates the general location of the Project and depicts the study locations and surrounding street system. The Level of Service (LOS) investigations at these key locations were used to evaluate the potential traffic circulation needs associated with area growth, cumulative projects, and the proposed Project. LINSCOTT, LAW & GREENSPAN, engineers 2 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana :>ht70{1111H7J7 -F,rs, H;ubor :\ltx.:d US<!. SantJ Ana'R,:1>01 t147J7 f115\ H.ubor :\{1�,:d-VS<:. Sa11r.1 .\na Traffic StuJy 10-23-23.<loc Exhibit D to Exhibit 2 W 5th St a 0• % l t S! t z :i: i GIi I SOURCE: GOOGLE KEY a (j) • STUDY INTERSECTION [?J = PROJECT SITE z f i 6L1Sl lQ ;z i w =Z W llll St ll: I � w SI W1stSt fl FIGURE 1-1 VICINITY MAP FIRST HARBOR MIXED-USE PROJECT, SANTA ANA i � � 1 � � Exhibit D to Exhibit 2 2.0 PROJECT DESCRIPTION The First Harbor Mixed-Use Project proposes to develop a nine-story building with 183 multifamily residential units (including studios, I-bedroom, 2-bedroom, and 3-bedroom units) and 15,182 SF of retail on the ground floor. Of the 183 total units proposed, 15% (28 units) would be designated as low-income housing. The residential and retail uses would wrap around a four-level parking structure, consisting of two subterranean levels, one street/ground level, and a second above-ground level, and provide a total of333 standard parking spaces. As presented previously, Figure 1-1 is the Vicinity Map, which shows the general location of the Project and surrounding street system. Figure 2-1 is an existing aerial photograph of the Project site. The Project is expected to be completed and fully occupied by Year 2028. As part of the Project-specific improvements planned at the intersection of Harbor Boulevard and I st Street (Intersection No. 2) previously approved by the City, the Project will be adding a right-tum pocket (with a total length of 213 feet, comprised of 186 feet of storage length, and 27 feet of transition length) along 1st Street on the westbound approach of the intersection. 2.1 Site Access Access to the Project will be provided via one (I) right-tum in/out only driveway on Harbor Boulevard and two (2) driveways restricted to left-turns/right-turns in, and right-turns out, on Figueroa Street. 2.2 Pedestrian and Bicycle Circulation Sidewalks are provided on both sides of the street throughout most of the City. Crosswalks, pedestrian push buttons, and pedestrian indication lights are provided at all signalized intersections adjacent to the Project site. The proposed Project plans to retain this existing pedestrian infrastructure. The proposed Project will encourage walking by integrating pedestrian connections internally, as well as to nearby activities. Pedestrian circulation would be provided via existing public sidewalks along Harbor Boulevard, I st Street, and Figueroa Street within the vicinity of the Project. The proposed Project will protect the existing sidewalk along Project frontage on these roadways. The existing sidewalk system within the Project vicinity provides direct connectivity to the existing development located along major thoroughfares. Long-term bicycle storage for the residential and retail uses will be provided in two bike rooms, totaling 96 long-term bike spaces. An additional four ( 4) bicycle spaces will be provided for short term bicycle storage purposes. According to the City of Santa Ana Bikeway Master Plan, Class IV Cycle Tracks are planned on Harbor Boulevard and I st Street along the Project's frontage. LINSCOTT, LAw&GREENSPAN, engineers 3 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit D to Exhibit 2 SOURCE: GOOGLE KEY [Z-:.:zl = PROJECT SITE FIGURE 2-1 EXISTING SITE AERIAL FIRST HARBOR MIXED-USE PROJECT, SANTA ANA Exhibit D to Exhibit 2 .. I• I -, .,;·., i i· ! I t � lI , -t _:II ]Gi t;I ; gi, . �, .0 w , �i .,;, I! :�. l -' i 1 r· i ... l ---+----------{-------W.FlRSTSTREl."T _________________ +---j I SOURCE: PRIMIOR FIGURE 2-2 PROPOSED SITE PLAN FIRST HARBOR MIXED-USE PROJECT, SANTA ANA Exhibit D to Exhibit 2 3.0 EXISTING (2023) CONDITIONS 3.1 Existing Street System The principal local network of streets serving the project site are Harbor Boulevard, 1 st Street, 5th Street and Figueroa Street. The following discussion provides a brief synopsis of these key area streets. The descriptions are based on an inventory of existing roadway conditions. Harbor Boulevard is generally a six-lane, divided roadway that borders the Project site to the west, oriented in the north-south direction that provides three northbound and three southbound travel lanes separated by a raised median. Harbor Boulevard will provide one (I) right-in/right-out driveway for the proposed Project. The posted speed limit on Harbor Boulevard is 40 miles per hour (mph). On-street parking is not permitted along this roadway in the vicinity of the project. The City of Santa Ana General Plan Circulation Element classifies Harbor Boulevard as a Major Arterial. Class II Buffered Bike Lanes are provided south of 1st Street in the vicinity of the project. Traffic signals control the study intersections of Harbor Boulevard at 5th Street and ]st Street. 1st Street is generally a six-lane, divided roadway that borders the Project site to the south, oriented in the east-west direction that provides three lanes in each direction separated by a TWL T striped median. The posted speed limit on I st Street is 40 mph. On-street parking is not permitted along this roadway in the vicinity of the project. The City of Santa Ana General Plan Circulation Element classifies 1st Street as a Major Arterial. Class II Buffered Bike Lanes are provided west of Harbor Boulevard in the vicinity of the project. 5th Street is generally a four-lane divided roadway east of Harbor Boulevard and a two-lane undivided roadway west of Harbor Boulevard, oriented in the east-west direction. The posted speed limit is 35 mph east of Harbor Boulevard and 30 mph west of Harbor Boulevard. On-street parking is only permitted on the north side of this roadway east of Harbor Boulevard in the vicinity of the project. The City of Santa Ana General Plan Circulation Element classifies 5th Street as a Secondary Arterial east of Harbor Boulevard and a Commuter west of Harbor Boulevard. Figueroa Street is a two-lane undivided roadway that borders the Project site to the east, oriented in the north-south direction. The prima facie speed limit is 25 mph and parking is permitted on both sides of the roadway. Figueroa Street will provide two (2) left-tum/right-turns in and right-tum out only driveways for the proposed Project. Figure 3-1 presents an inventory of the ex1stmg roadway conditions for the arterials and intersections evaluated in this report. This figure identifies the number of travel lanes for key arterials, as well as intersection configurations and controls for the key area study intersections. 3.2 Existing Traffic Volumes Two (2) key study intersections and one (1) key roadway segment have been identified as the locations at which to evaluate existing and future traffic operating conditions. Some portion of potential project-related traffic will pass through each of these intersections, and their analysis will reveal the potential need for Project-related circulation improvements. These key locations were LINSCOTT, LAW & GREENSPAN, engineers 4 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit D to Exhibit 2 2U 5TH l30J 60 1ST l 4-0J NO SCALE 8 PHASE SIGNAL L 4i++l.) - NP ' 40 NP _J itt�l35J t ..., G) C �gi l"'1 ;;o 0 ..... l> NN CJIC l> ..... ;;o CD 0 ;;o "U "U �� (/) -f t::. ·::. ·::. ·::. ·::) I ............. -�.............. . . . . . . . . . . . . . . :-:-:-:-:-:-:-:-:-:-:-:-:-:-] 8 PHASE �············1SIGNAL ........... ........... ........... ]..JU+� ........... Ji,-• .......... NP ............ ...., NP :!J ittti ----t �gi ..... r cS �� KEY - = APPROACH LANE ASSIGNMENTe= TRAFFIC SIGNAL, -r = STOP SIGN P = PARKING, NP = NO PARKING ST p NP 1m ST IJP ( 4-0) NP FIGURE 3-1 U = UNDIVIDED, D = DIVIDED 2 = NUMBER OF TRAVEL LANES (XX)= POSTED SPEED LIMIT (MPH) ma -PROJECT SITE EXISTING ROADWAY CONDITIONS AND INTERSECTION CONTROLS FIRST HARBOR MIXED-USE PROJECT, SANTA ANA i ,,, N N .!. ' S? ..... 0 ,,, � 0.. 9 "' • '! ' !:? ...,,,... / "' • / 0 0 " :l =� "ll -�I "' I ... ... N N / c Exhibit D to Exhibit 2 selected for evaluation based on discussions with City of Santa Ana staff and in consideration of Orange County CMP requirements. Existing daily, AM peak hour and PM peak hour traffic volumes for the two (2) key study intersections and one (I) key roadway segment evaluated in this report were obtained from manual turning movement counts conducted by Transportation Studies, inc. in August 2023. Figures 3-2 and 3-3 illustrate the existing AM and PM peak hour traffic volumes at the two (2) key study intersections evaluated in this report, respectively. Figure 3-3 also presents the existing average daily traffic volumes for the one (I) key roadway segment in the vicinity of the proposed Project. Appendix A contains the detailed peak hour and daily traffic count sheets for the key intersections and roadway segments evaluated in this report. 3.3 Existing Public Transportation Public transit bus service is provided in the project area by the Orange County Transportation Authority (OCTA). Figure 1-1 identifies the bus stop locations nearest to the Project site. Three (3) OCT A bus routes operate within the vicinity of the Project site on Harbor Boulevard and I st Street, which consist of the following: •OCTA Route 43 (Fullerton to Costa Mesa): Route 43 is a local bus route serving the Cities of Fullerton, Anaheim, Garden Grove, Santa Ana, Fountain Valley and Costa Mesa. The major route of travel is along Harbor Boulevard in the vicinity of the project. Route 43 connects to the Fullerton Transportation Center, approximately 13.8 miles from the Project site, which also connects to OCTA Routes 26, 47, 143, and 543 as well as Metrolink/Amtrak. Route 43 operates on approximately 20-minute headways during weekdays and 15-minute headways on weekends. Nearest to the project site are bus stops on Harbor Boulevard -northbound and southbound, south of pt Street. The northbound bus stop is located approximately 210 feet from the Project site and the southbound bus stop is located approximately 460 feet from the Project site. •OCTA Route 64 (Huntington Beach to Tustin): Route 64 is a local bus route serving the Cities of Tustin, Santa Ana, Garden Grove, Westminster, Midway City and Huntington Beach. The major route of travel is along I st Street in the vicinity of the project. Route 64 operates on approximately IS-minute headways during weekdays and 20-minute headways on weekends. Nearest to the project site are bus stops on I st Street -eastbound and westbound, at its intersection with Harbor Boulevard. The eastbound bus stop is located approximately 210 feet from the Project site and the westbound bus stop is located approximately 230 feet from the Project site. •OCTA Route 543 (Fullerton Transportation Center to Santa Ana): Route 543 is a Bravo route serving the Cities of Fullerton, Anaheim, Garden Grove, Santa Ana and Costa Mesa. The major route of travel is along Harbor Boulevard in the vicinity of the project. Route 543 connects to the Fullerton Transportation Center, approximately 13 .8 miles from the Project site, which also connects to OCTA Routes 26, 43, 47, and 143 as well as Metrolink/Amtrak. Route 543 operates LINSCOTT, LAW & GREENSPAN, engineers 5 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit D to Exhibit 2 LINSCOTT LAW & GREENSPAN engineers 5TH 1ST �O SCALE ..,. co--0>1n co--) I l 94_,I 138-76, \.._ 163 -921.-139)l.( �co ::i: )> ;:o (D 0 ;:o r. '::. '::. ·::. ·:::ir ..............I.............. ,.............. :-:-:-:-:-:-:-:-:-:-:-:-:-:-] -:-:-:-:-:-:-:-:-:-:-:-:-:-:1 :-:-:-:-:-:-:-:-:-:-:-:-:-:-] ... · ·.·;.:,,,,,·;_;,,,,·�-. •. KEY [fil:fil = PROJECT SITE ST ::!l G) C rr, ;:o 0 )> ST FIGURE 3-2 EXISTING AM PEAK HOUR TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA ::l l;l I 8 I 0 "-9 .......,I C Exhibit D to Exhibit 2 LINSCOTT LAW & GREENSPAN engineers 5TH 1ST IO �a� Jll 55J 130-65, \,_ 269 -211, 114 �kf ,-...� :r )> ;o CD 0 ;o r-:. ·::. ·::. ·::: ·::J t ·:-:-:-:-:-:-:-:-:-:-:-:-:-:4 :-:-:-:-:-:-:-:-:-:-:-:-:-:-] -:-:-:-:-:-:-:-:-:-:-:-:-:-:➔ :-:-:-:-:-:-:-:-:-:-:-:-:-:-] ··.·:..:_.·�······.1 KEY ..,S&!L = DAILY TRAFFIC VOLUMES � = PROJECT SITE ,, G) C fTl ;o 0 )> ,� (/) -i ST ST FIGURE 3-3 EXISTING PM PEAK HOUR AND DAILY TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA .., N 0 N I I 0 ., N N .., s 9 "' • .., ,.; I !;! Exhibit D to Exhibit 2 on approximately 25-minute headways during weekdays and is closed on the weekends. Nearest to the project site are bus stops on Harbor Boulevard - northbound and southbound, south of I st Street. The northbound bus stop is located approximately 210 feet from the Project site and the southbound bus stop is located approximately 460 feet from the Project site. 3.4 Existing Intersection Conditions Existing AM and PM peak hour operating conditions for the two (2) key study intersections were evaluated using the Intersection Capacity Utilization (ICU) methodology for signalized intersections and the methodology outlined in the Highway Capacity Manual 6 (HCM 6) for unsignalized intersections (i.e. project driveways). 3.4.1 Intersection Capacity Utilization (ICU) Method of Analysis In conformance with City of Santa Ana requirements, existing AM and PM peak hour operating conditions for the key signalized study intersections were evaluated using the Intersection Capacity Utilization (ICU) method. The ICU technique is intended for signalized intersection analysis and estimates the volume to capacity (Y/C) relationship for an intersection based on the individual V/C ratios for key conflicting traffic movements. The ICU numerical value represents the percent signal (green) time, and thus capacity, required by existing and/or future traffic. It should be noted that the ICU methodology assumes uniform traffic distribution per intersection approach lane and optimal signal timing. Per City of Santa Ana requirements, the ICU calculations use a lane capacity of 1,700 vehicles per hour (vph) for through lanes and 1,600 vph for left-tum lanes and right-tum lanes. A clearance adjustment factor of 0.05 was added to each Level of Service calculation. The ICU value translates to a Level of Service (LOS) estimate, which is a relative measure of the intersection performance. The ICU value is the sum of the critical volume to capacity ratios at an intersection; it is not intended to be indicative of the LOS of each of the individual turning movements. The six qualitative categories of Level of Service have been defined along with the corresponding ICU value range and are shown in Table 3-1. 3.4.2 Highway Capacity Manual (HCM) Method of Analysis (Unsignalized Intersections) The HCM unsignalized methodology for stop-controlled intersections was utilized for the analysis of the unsignalized intersections. This methodology estimates the average control delay for each of the subject movements and determines the level of service for each movement. For all-way stop controlled intersections, the overall average control delay measured in seconds per vehicle, and level of service is then calculated for the entire intersection. For one-way and two-way stop-controlled (minor street stop-controlled) intersections, this methodology estimates the worst side street delay, measured in seconds per vehicle and determines the level of service for that approach. The HCM control delay value translates to a Level of Service (LOS) estimate, which is a relative measure of the intersection performance. The six qualitative categories of Level of Service have been defined along with the corresponding HCM control delay value range, as shown in Table 3-2. LINSCOTT, l.Aw&GREENSPAN, engineers 6 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N.14700\2�H7J7 -First Harbllr :\fix�d lJ;�. SantJ AnJ1R�1mrt147J7 Fust Harl>or ,\h>.�d-l'se, Salltn .\n,1 Tr:iffic Study W-23-23 00.: Exhibit D to Exhibit 2 TABLE 3-1 LEVEL OF SERVICE CRITERIA FOR SIGNALIZED INTERSECTIONS (ICU METHODOLOGY) Level of Service (LOS) B C E F LINSCOTT, LAW&GREENSPAN, engineers Intersection Capacity Utilization Value (V/C) ,;; 0.600 0.601 -0.700 0. 70 I -0.800 0.80 I -0.900 0.90 I -1.000 >1.000 7 Level of Service Description EXCELLENT. No vehicle waits longer than one red light, and no approach phase is fully used. VERY GOOD. An occasional approach phase is fully utilized; many drivers begin to feel somewhat restricted within groups of vehicles. GOOD. Occasionally drivers may have to wait through more than one red light; backups may develop behind turning vehicles. FAIR. Delays may be substantial during portions of the rush hours, but enough lower volume periods occur to permit clearing of developing lines, preventing excessive backups. POOR. Represents the most vehicles intersection approaches can accommodate; may be long lines of waiting vehicles through several signal cycles. FAILURE. Backups from nearby locations or on cross streets may restrict or prevent movement of vehicles out of the intersection approaches. Potentially very long delays with continuously increasing queue lengths. LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana K;,--1700\2234737 • Fim H.11bor :,.fi��d Use. S:mt:t Ana1R�port\�737 fil'st Harhor .\hwd-l 'se.. Santa .\n:t Troffic Study !0-23-23 doc Exhibit D to Exhibit 2 TABLE3-2 LEVEL OF SERVICE CRITERIA FOR UNSIGNALIZED INTERSECTIONS (HCM METHODOLOGY)' Level of Service Highway Capacity Manual (HCM) (LOS) Delay Per Vehicle (seconds/vehicle) Level of Service Description A s; 10.0 Little or no delay B >10.0ands; 15.0 Short traffic delays C >15.0 ands; 25.0 Average traffic delays D >25.0 ands; 35.0 Long traffic delays E >35.0 ands; 50.0 Very long traffic delays F >50.0 Severe congestion Source: Highway Capacity Manual 7'1' Edition, Chapter 20: Two-Way Stop-Controlled Intersections. The LOS criteria apply to each lane on a given approach and to each approach on the minor street. LOS is not calculated for major-street approaches or for the intersection as a whole. LINSCOTT, LAw&GREENSPAN, engineers 8 LLG Re[ 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit D to Exhibit 2 3.4.3 Level of Service Criteria According to the City of Santa Ana, LOS D is the minimum acceptable condition that should be maintained during the peak commute hours. However, the City of Santa Ana has defined exceptions to this criterion at specific locations within the study area. The City of Santa Ana has defined major development areas where LOS "E" is considered acceptable. Based on the above, the following summarizes the LOS required for each key study intersection: LOS "D" Requirements LOS "E" Requirements I.Harbor Boulevard at 5th Street 2.Harbor Boulevard at I st Street 3.5 Existing Level of Service Results Table 3-3 summarizes the existing peak hour service level calculations for the two (2) key study intersections based on existing traffic volumes and current street geometrics. Review of Table 3-3 indicates that all key study intersections currently operate at an acceptable level of service (LOS) during the AM and PM peak hours when compared to the LOS criteria defined in this report. Appendix B presents the ICU/LOS calculation worksheets for the two (2) key study intersections for the AM peak hour and PM peak hour. LINSCOTT, LAW & GREENSPAN, engineers 9 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit D to Exhibit 2 TABLE3-3 EXISTING PEAK HOUR INTERSECTION CAPACITY ANALYSIS Minimum Acceptable Control Time Key Intersection Jurisdiction LOS Type Period ICU LOS Harbor Boulevard at 80 Traffic AM 0.719 I. 5th Street Santa Ana D Signal PM 0.729 C Harbor Boulevard at 80 Traffic AM 0.760 2. Santa Ana E Signal I st Street PM 0.811 D Bold ICU values indicate adverse service levels based on the Cities LOS standards. LINSCOTT, LAW & GREENSPAN, enginee/S 10 LLG Ref 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Is ,.:17W122347l7 • F1m Rubor \h>.,:d Usi.:. S:mta Ana'RcporN7J7 f1r<1 Harl-or \lv,�-d-Use. Santa .\na Traffic Stud� 10-23-23 doc Exhibit D to Exhibit 2 4.0 TRAFFIC FORECASTS In order to estimate the traffic characteristics of the proposed Project, a multi-step process has been utilized. The first step is trip generation, which estimates the total arriving and departing traffic on a peak hour and daily basis. The traffic generation potential is forecast by applying the appropriate vehicle trip generation equations or rates to the Project development tabulation. The second step of the forecasting process is trip distribution, which identifies the origins and destinations of inbound and outbound Project traffic. These origins and destinations are typically based on demographics and existing/anticipated travel patterns in the study area. The third step is traffic assignment, which involves the allocation of Project traffic to study area streets and intersections. Traffic assignment is typically based on minimization of travel time, which may or may not involve the shortest route, depending on prevailing operating conditions and travel speeds. Traffic distribution patterns are indicated by general percentage orientation, while traffic assignment allocates specific volume forecasts to individual roadway links and intersection turning movements throughout the study area. With the forecasting process complete and Project traffic assigntiients developed, the effect of the proposed Project's added traffic is isolated by comparing operational (LOS) conditions at selected key intersections using expected future traffic volumes with and without forecast Project traffic. The need for site-specific and/or cumulative local area traffic improvements can then be evaluated. LINSCOTT, LAw&GREENSPAN, engineers 11 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit D to Exhibit 2 4.1 Project Traffic Generation Traffic generation is expressed in vehicle trip ends, defined as one-way vehicular movements, either entering or exiting the generating land use. Generation equations and/or rates used in the traffic forecasting procedure are found in the 11th Edition of Trip Generation, published by the Institute of Transportation Engineers (]TE) [Washington D.C., 2021]. The upper portion of Table 4-1 summarizes the trip generation rates used in forecasting the vehicular trips generated by the proposed Project. As shown in Table 4-1, !TE Land Use 221: Multifamily Housing Mid Rise and !TE Land Use 822: Strip Retail Plaza Less than 40K trip rates were used to forecast the trip generation potential of the proposed Project. The lower portion of Table 4-1 presents the project's forecast peak hour and daily traffic volumes, inclusive of applicable pass-by trip reductions. As shown on the bottom of Table 4-1, the proposed Project is forecast to generate approximately 1,575 daily trips, with I 00 trips (36 inbound, 64 outbound) produced in the AM peak hour and 131 trips (73 inbound, 58 outbound) produced in the PM peak hour on a "typical" weekday. Please note that trip generation for the proposed Project includes adjustments for pass-by as recommended by !TE. The pass-by reduction factors are based on a review of available information published in the 11th Edition of Trip Generation, published by the Institute of Transportation Engineers (!TE), [Washington, D.C., 2021]. 4.2 Project Traffic Distribution and Assignment Figure 4-1 presents the traffic distribution pattern for the proposed Project. Project traffic volumes both entering and exiting the project site have been distributed and assigned to the adjacent street system based on the following considerations: ■ location of site access points in relation to the surrounding street system, ■the site's proximity to major traffic carriers and regional access routes, ■ physical characteristics of the circulation system such as lane channelization and presence oftraffic signals that affect travel patterns, ■presence of traffic congestion in the surrounding vicinity, and•ingress/egress availability at the project site, as well as allowance of "U-turn" movements at5th Street and 1st Street. The anticipated AM and PM peak hour project traffic volumes associated with the proposed Project are presented in Figures 4-2 and 4-3, respectively. Figure 4-3 also presents the daily Project traffic volumes. The traffic volume assignments presented in Figures 4-2 and 4-3 reflect the traffic distribution characteristics shown in Figure 4-1 and the traffic generation forecast presented in Table 4-1. LINSCOTT, LAW & GREENSPAN, engineers 12 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana � -'700\:�34737 -f,rst H�rbor \1,,..,d l 'se. S:uttJ And'R�pon'47J7 Fir$! Harl"'r \h.>..:d-l'.�, S.111ta ;\n;1 Traffic Study l0-2J-2J.doc Exhibit D to Exhibit 2 TABLE4-1 PROJECT TRAFFIC GENERATION FORECAST' !TE Land Use Code I Daily AM Peak Hour PM Peak Hour Project Description 2-Way Enter Exit Total Enter Exit Total Generation Factors: •221: Multifamily Housing Mid Rise (TE/DU) •822: Strip Retail Plaza Less than 40K (TEffSF) Proupsed Pro[ect Generation Forecast: •Residential (183 DU) •Retail (15,182 SF) Pass-by (Daily: IO%, AM: I 0% PM: 40%)3 Retail Subtotal Total Project Trip Generation Notes: •TE/DU = Trip ends per dwelling unit•TEffSF = Trip ends per thousand square feet 4.54 23% 54.45 60% 831 16 827 22 -83 :6 744 20 1,575 36 77% 0.37 61% 39% 40% 2.36 50% 50% 52 68 43 28 14 36 50 50 :6 .:1 -20 -20 12 32 30 30 64 100 73 58 2 3 Source: Trip Generation, 11th Edition, Institute ofTransportation Engineers, (ITE) [Washington, D.C. (2021)}. Source: The /TE Trip Generation Manual does not contain pass-by infonnatioti for the ITE LU 822: Strip Retail Plaza Less than 40K. Therefore, the Daily, AM peak hour, and PM peak hour pass-by rates were conservatively assumed to be 10% (estimated) for Daily, 10% (estimated) for AM peak hour, and 40% for PM peak hour (consistent with ITE LU 821 pass-by rates). LINSCOTT, LAW & GREENSPAN, engineelS 13 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana 0.39 6.59 71 JOO -40 60 131 Exhibit D to Exhibit 2 � 5TH <)g◊. 1ST LINSCOTT LAW & GREENSPAN engineers �NO SCALE � 0 I') � 5ll:9 8 95,: flit j���� 01()01{) � n I )> :;o OJ 0 :;o ............... :!J G) C fT1 :;o 0 )> ::::::.fitN :f� [;-.............. I' ........ ·:::::::::::::.'- ST <)v ST KEY @ ,. STUDY INTERSECTION q-= INBOUND PERCENTAGE FIGURE 4-1 - = OUTBOUND PERCENTAGE PROJECT TRAFFIC rz:a = PROJECT s1TE n1sTRIBUTION PATTERN FIRST HARBOR MIXED-USE PROJECT, SANTA ANA 9 Exhibit D to Exhibit 2 LINSCOTT LAW & GREENSPAN engineerc. 5TH 1ST �O SCALE o:=o JI l... o--J o-2, \._ 0 -or2)�.( I )> ;;o CD 0 ;;o CD r KEY (XX)= PASS-BY TRIPS�ii = PROJECT SITE ST :::!:l 0 )> \ \ FIGURE 4-2 AM PEAK HOUR PROJECT TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA 9 Exhibit D to Exhibit 2 LINSCOTT LAW & GREENSPAN e11gineers 5TI-i 1ST �OSCALE N \._ 0ONO -oJ I I... ,4 ST o-' ill! o-4, C fT1 ;;o 0 )> I > ;;o ID 1� 0 ;;o ,,-r--,,,,,-�, ,, / ' / ' I � \ Vl I 00 \ I I \._ 29(9)J � 1 J I \ \ I ( I \ 9(aellt Io,:::-/\I 'co' I \ � ✓-...... / ' I/')< / - - _,, -_ _,, / ' -_(-.-. .'":"T.'":"T.'":"T.� [\--'" 7WY 1.'.'.'0WYT.' t-·.·.·.·.·.·.·.·.·:.·.·.·.·.� :·:·:·:·:·:·:·:·:·:·:·:·:·:·] ::::::-ow :s·� 1)--................. f' ....... ·:::::::::::::." ST ID § KEY Aa = DAILY TRAFFIC VOLUMES (XX)= PASS-BY TRIPS '\ \ >---r--' / §: ' I oo, \ , J I \ \ 20(3�1,l. I \ � I ' - / --_,, FIGURE 4-3 �:� = PROJECT SITE PM PEAK HOUR AND DAILY PROJECT TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA I .., Exhibit D to Exhibit 2 4.3 Existing Plus Project Traffic Volumes The Existing Plus Project traffic conditions have been generated based upon existing conditions and the estimated project traffic. These forecast traffic conditions have been prepared to assess the potential effects of the Project upon the circulation system as it currently exists per the requirements of the City. This traffic volume scenario and the related intersection capacity analyses will identify the roadway improvements necessary to offset the Project, if any. Figures 4-4 and 4-5 present projected AM and PM peak hour traffic volumes at the two (2) key study intersections and three (3) Project driveways with the addition of the trips generated by the proposed Project to existing traffic volumes, respectively. Figure 4-5 also presents the Existing Plus Project daily traffic volumes. 4.4 Year 2028 Cumulative Base 4.4.1 Ambient Traffic Growth Horizon year, background traffic growth estimates have been calculated using an ambient traffic growth factor. The ambient traffic growth factor is intended to include unknown and future related projects in the study area, as well as account for regular growth in traffic volumes due to the development of projects outside the study area. The future growth in traffic volumes has been calculated at one percent (1.0%) per year. Applied to the Year 2023 existing traffic volumes, this factor results in a 5.0% growth in existing volumes to the near-term horizon year 2028. 4.4.2 Cumulative Projects In order to make a realistic estimate of future on-street conditions prior to implementation of the proposed Project, the status of other known development projects (related projects) within a two mile radius of the proposed project has been researched at the City of Santa Ana, City of Garden Grove, City of Fountain Valley and City of Westminster. With this information, the potential circulation effects of the proposed Project can be evaluated within the context of the cumulative impact of all ongoing development. Based on our research during the scoping process, there are nine (9) related projects in the City of Santa Ana and one (1) related project in the City of Garden Grove that are being processed for approval or to be constructed and fully operational within a two-mile radius of the proposed project site. These ten (10) related projects have been included as part of the cumulative background setting. Table 4-2 provides a brief description for each of the ten (10) related projects. Figure 4-6 graphically illustrates the location of the ten (10) related projects. These related projects are expected to generate vehicular traffic, which may affect the operating conditions of the key study intersections. Table 4-3 summarizes the trip generation potential for all ten (10) related projects on a daily and peak hour basis for a typical weekday. As shown, the related projects are expected to generate 4,705 daily trips, with 245 trips (103 inbound, 142 outbound) anticipated during the AM peak hour and 287 trips (162 inbound, 125 outbound) produced during the PM peak hour. LINSCOTT, LAW & GREENSPAN, engineers 14 LLG Ref 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit D to Exhibit 2 LINSCOTT LAW & GREENSPAN engineers 5TH 1ST I I \ ,,.....-;r--, / � '\. N I \.._ 33 I.( "'--o,LO«>-- ) I l... 94---' 138- 78, \ I I \ �N I'-:---< ...._ \.._ 163 -92,-141 �l! .. <O - I ;o CD 0 '---l �_.,..,._.,..,._..,..,.:-=lrl [:I?"!!.!-:-:-��?-� --......_ / /N / ......... \.._ ,so< o,-..n I --N -533\I ) I l ,-216 I \ 149---' )!! / 835-\ 197, �:8�/ '-/ ...._ - _,, .............. :-:-:-:-:-:-:-:-:-:-:-:-:-:-] . ·::.·.·.·.·.·.·.·.·:.·.•j ::::::.ow{ :s·� .............. 1 . . .. . . . . .. . . . . .............. .. ........ / / / CD r s KEY fiil = PROJECT SITE ;o 0 l> -t �/ >' � ' ST ,,.....-,--......_/ 0� I ) I I \ o---' 1� \ /'-/ ...._ '\. \ \ '\. \ I )J I N I/ L.. _,, ST )..- - r-- ......_ / " 0� \ I I ) I I \ o---' 11 I 22, .og \ I ' / ...._ L.. _,, FIGURE 4-4 EXISTING PLUS PROJECT AM PEAK HOUR TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA "' N � I N I � ;. ,;; ;; I :!. ...."' .... •,.;; 0 e 0 � ii : � 'll i � 0 � I ....• ....• e Exhibit D to Exhibit 2 LINSCOTT LAW & GREENSPAN engineers 5TH 1ST I I \ ,,,,.-r-' / � '\. N I \.._ 3J t r Olt'l ..,._"' <ON- ) I l gg-J 146-82, \ I I 00> \ <ON I N - < '--- _,,. '-....( / / / �-.--, / /:2�� \.._ 191 I --N -668\I ) j l r 227 \ \ 158_./ ),1.( I \ 879-���/20� / '--.... _,,. \.._ 171 -97, 110 ��f N :c )> ;:o CD 0 ;:o �_..,..,._..,..,._.,...._� [:��-!-:-:-:��-:�-� .............. :-:-:-:-:-:-:-:-:-:-:-:-:-:-] ···········:4·· .............. -:-:-:-:-:-:��:-}::: .. . . . . . . .. . ... • •:• ·:· ·:··:.'I CD r s KEY :!! C) C fTI ;:o 0 )> t� Vl -t '\,--/ ., � ' ST ,,,,.-/ 0� I ) l I o-' \ 1� \ /'-/ - '- '\ \ .--, '\. \ \ 'I t I ,..,00 N I / .__,,- ST ).--,.._' / o::S '\. I \ I ) I \ o-' 1 t I \ 22, "',';i \ I '-/ -- _,,. �OSCALE � = DAILY TRAmc VOLUMES [fil:::/J -PROJECT SITE FIGURE 4-5 EXISTING PLUS PROJECT PM PEAK HOUR AND DAILY TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA i 2 a. j ..., N 0 N I ..., N I :;! ;;; : ,;; 9 "' I :!: ......,...•�• g 0 � a:i2 E � _g i?"' I ...•..., • ,('. C Exhibit D to Exhibit 2 TABLE4·2 LOCATION AND DESCRIPTION OF CUMULATIVE PROJECTS' No. Cumulative Project City of Santa Ana I.Habitat for Humanity 2.Westview Housing 3.Haphan Residential Development 4.Bewley Street Townhomes 5. 5th and Harbor Mixed-UseDevelopment 6. Bella Terra Residential Community and Temple 7. Mountain View 8-Unit Condominium Development 8.Coptic Orthodox Church Euclid-Hazard ?-Eleven Service9. Station City o(Garden Grove 10.Harbor Place Pad Building Notes: SF= Square-feet DU = Dwelling units VFP = Vehicle Fueling Positions Location/Address 1921 West Washington Avenue 2534 West Westminster Avenue 3025 West Edinger Avenue 1122 North Bewley Street 419-421 North Harbor Boulevard 4006,4010, aud 4018 West Hazard Avenue 301 and 305 North Mountain View Street 4405 West Edinger Avenue 813 North Euclid Street 13200-13220 Harbor Boulevard 4 Source: City of Santa Ana and City of Garden Grove Planning Departments. LINSCOTT, LAw&GREENSPAN, engineers 15 Description 6 DU Affordable Housing 85 DU Multi-family Residential 18 DU Multi-family Residential 10 DU Condominium 94 DU Multi-family Residential 9,500 SF Retail 13 DU Single-family Residential 3,500 SF Temple 8 DU Condominium 110 Seat Expansion for Church 8VFP 3,045 SF Convenience Store 2,800 SF Fast Food Restaurant with Drive-thru 1,200 SF Restaurant LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit D to Exhibit 2 KEY 1. HABITAT FOR HUMANITY 2. WESTVIEW HOUSING 3. HAPHAN RESIDENTIAL DEVELOPMENT 4. BEWLEY STREET TOWNHOMES 5. 5TH AND HARBOR MIXED-USE DEVELOPMENT 6. BELLA TERRA RESIDENTIAL COMMUNITY AND TEMPLE 7. MOUNTAIN VIEW 8-UNIT CONDOMINIUMS DEVELOPMENT 8. COPTIC ORTHODOX CHURCH 9. EUCLID-HARARD 7-ELEVEN SERVICE STATION 10. HARBOR PLACE PAD BUILDING Garden Grove' f J i I KEY (j) CUMULATIVE PROJECT LOCATION E\] -PROJECT SITE FIGURE 4-6 LOCATION OF CUMULATIVE PROJECTS FIRST HARBOR MIXED-USE PROJECT, SANTA ANA Exhibit D to Exhibit 2 TABLE4-3 CUMULATIVE PROJECTS TRAFFIC GENERATION FORECAST' Daily AM Peak Hour PM Peak Hour Cumulative Project Description 2-Way In Out Total In Out Total l.Habitat for Humanity 40 0 2 2 2 I 2.Westview Housing 573 8 26 34 27 16 3.Haphan Residential Development 121 2 5 7 6 3 4.Bewley Street Townhomes 67 I 3 4 3 2 5.5th and Harbor Mixed-Use Development 1,099 21 37 58 49 37 6. Bella Terra Residential Community and Temple 115 2 4 6 5 4 7.Mountain View 8-Unit CondominiumDevelopment 54 I 2 3 3 I 8.Coptic Orthodox Church 99 5 3 8 5 6 9.Euclid-Hazard ?-Eleven Service Station 1,426 , 25 25 50 33 32 10.Harbor Place Pad Building 1,111 38 35 73 29 23 Cumulative Projects 4,705 103 Total Trip Generation Potential 142 245 162 125 s Unless otherwise noted, Source: Trip Generation, 1 l1h Edition, Institute of Transportation Engineers (ITE), Washington, D.C. (2021). LINSCOTT, LAW & GREENSPAN, engineers 16 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana 3 43 9 5 86 9 4 11 65 52 287 Exhibit D to Exhibit 2 The AM and PM peak hour traffic volumes associated with the ten (I 0) related projects in the Year 2028 are presented in Figures 4-7 and 4-8, respectively. Figure 4-8 also presents the daily related project traffic volumes. 4.4.3 Year 2028 Cumulative Base Traffic Volumes Figures 4-9 and 4-10 present the AM and PM peak hour cumulative base traffic volumes ( existing traffic + ambient growth + cumulative projects) at the two (2) key study intersections for the Year 2028, respectively. 4.4.4 Year 2028 Cumulative Plus Project Traffic Volumes Figures 4-11 and 4-12 illustrate the Year 2028 forecast AM and PM peak hour traffic volumes, with the inclusion of the trips generated by the proposed Project, respectively. LINSCOTT, LAW&GREENSPAN, engineers 17 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N ,-J700\12H7J7 -Ftr�t H:ubor Mi�"J L-se. S:mta AJ1a'Rc1)011·-HJ7 fm,t Harbor �fixed-Use. Santa .\na Traffic Study lfJ-23-23.doc Exhibit D to Exhibit 2 LINSCOTT LAW & GREENSPAN engineer, 5TH 1ST �O SCALE OO>CO Jll.... o-' 1-°' \__ 0 -or 22:)J[ I ► ;o (D 0 ;o r.':. ·::. ·::. ·::: • ::'1 t ............. -�.............. . . . . . . . .. . . .. . � .............. 1. . . . . . . .. . . . . . .............. -:-:-:-:-:-:-:-:-:-:-:-:-:-:1 :-:-:-:-:-:-:-:-:-:-:-:-:-:-] KEY fE:)� = PROJECT SITE 0 ► (/) --i ST ST FIGURE 4-7 AM PEAK HOUR CUMULATIVE PROJECT TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA I .., N I 9 "' • I � Exhibit D to Exhibit 2 LINSCOTT LAW & GREENSPAN engi11een 5TH 1ST �OSCALE CCX>� \.._ 0 ) � l,. -or 22o---' �.LC 2- � :r: CD 0 ;:o KEY ...BJ2!L • OAJLY TRAFFIC VOLUMES �� = PROJECT SITE :!l fTI ;:o 0 )> lo (/) -i ST ST FIGURE 4-8 PM PEAK HOUR AND DAILY CUMULATIVE PROJECT TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA N I I 0 9 Exhibit D to Exhibit 2 LINSCOTT LAW & GREENSPAN engineen 5TH 1ST �O SCALE �g;in(ON� Jil 99---' 146-BO-\ \._ 171 -97 r 1ss �if r )> w 0 ;:o r.·::.·::.·::.·:::i-:-:-:-:-:-:-:-:-:-:-:-:-:-:� :-:-:-:-:-:-:-:-:-:-:-:-:-:-] -:-:-:-:-:-:-:-:-:-:-:-:-:-:1 :-:-:-:-:-:-:-:-:-:-:-:-:-:-] w s KEY filll = PROJECT SITE )> (/) -t ST ST FIGURE 4-9 YEAR 2028 AM PEAK HOUR CUMULATIVE BASE TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA I .... N I 0 ;. 00 9 Exhibit D to Exhibit 2 LINSCOTT LAW & GREENSPAN e11gi11eers 51H 1ST �OSCALE :3in <D•r--co�� J I \.. 58-' 139-68, \._ 282 -222r 142)Ir a,�� I )> ;u CD 0 ;u f::::::::::::::J [·:-:-:-:-:-:-:-:-:-:-:-:-:-:�:-:-:-:-:-:-:-:-:-:-:-:-:-:-]-:-:-:-:-:-:-:-:-:-:-:-:-:-:1:-:-:-:-:-:-:-:-:-:-:-:-:-:-] • ·:,:,.:_: ••••••• ·.1 CD KEY � = DAILY TRAFFIC VOLUMES Elful = PROJECT SITE 0 )> 1, (/) --l ST ST FIGURE 4-10 YEAR 2028 PM PEAK HOUR AND DAILY CUMULATIVE BASE TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA I ,,,NI Exhibit D to Exhibit 2 LINSCOTT LAW & GREENSPAN engineers 5TH 1ST �O SCALE ,., ..,.oin \.._ 171 r.oN� -97Jll r 110 ST gg-J �.i.( 146-in -"' 82, N "Tl G) C ITI :;:o 0 )> ::i:: )> :;:o CD 0 _:;:o ............... ::::::.ow{ :f.,'..:j 1)---.. •:•:<-:·:•:·:·:·:·:·:·:·:·:" ', ... """"""'-" ST KEY �� = PROJECT SITE FIGURE 4-11 YEAR 2028 AM PEAK HOUR CUMULATIVE PLUS PROJECT TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA ..,� I ..,N I 0 Exhibit D to Exhibit 2 LINSCOTT LAW & GREENSPAN engineers 5TH 1ST �OSCALE IO '---282:g�� ---222Jll r 146 58_) �1!139-n, -�� I > ;:o Ill 0 ;:o Ill � KEY ...!!a1Q!L = DAILY TRAFFIC VOLUMES �❖:m = PROJECT SITE ST ::!l "' C fTl ;o 0 > ti \ \ FIGURE 4-12 YEAR 2028 PM PEAK HOUR AND DAILY CUMULATIVE PLUS PROJECT TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA I .., N I 0 ,._ .., ,._ I .. :, Exhibit D to Exhibit 2 5.0 NON-CEQA TRAFFIC ANALYSIS The relative effect of the proposed Project during the AM peak hour and PM peak hour was evaluated based on analysis of future operating conditions at the two (2) key study intersections, without, then with, the proposed Project. The previously discussed capacity analysis procedures were utilized to investigate the future volume-to-capacity relationships and LOS characteristics at each study intersection. The potential effect of the Project at each key intersection was then evaluated using LOS standards and thresholds summarized below. 5.1 LOS Standards and Thresholds 5.1.1 City of Santa Ana Based on the City of Santa Ana, the need for potential improvements will be assessed based on the following criteria: ■ Project traffic would cause an intersection currently operating at an acceptable peak hour Levelof Service (LOS) to operate at an unacceptable peak hour LOS. The City of Santa Ana considersLOS D to be the minimum acceptable LOS for all intersections, or •The project increases traffic demand by 1% of capacity (ICU increase� 0.01) if the intersectionalready operates at an unacceptable LOS. ■At unsignalized intersections, the project causes an intersection at LOS D or better to degrade toLOS EorF. 5.2 Traffic Analysis Scenarios The following scenarios are those for which volume/capacity calculations have been performed at the five (5) key intersections for existing plus project and near-term (Year 2028) traffic conditions: A.Existing Traffic Conditions; B.Existing Plus Project Traffic Conditions; C.Scenario (B) with Improvements, if necessary; D.Near-Term (Year 2028) Cumulative Traffic Conditions, E.Near-Term (Year 2028) Cumulative plus Project Traffic Conditions; F.Scenario (E) with Project-Related Mitigation, if necessary. LINSCOTT, LAW & GREENSPAN, engineers 18 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N ,-1700·213�737 -F,rsl Ha,bor �h��d t.::�e. S:tnt:t Ana'Rt1lort'47J7 Fust HaJ l'Or M,��d-l'�. Sa.iu:i .\n:t Traffic Stud) 10-2J-23.doc Exhibit D to Exhibit 2 5.3 Existing (2023) Plus Project Traffic Conditions Table 5-1 summarizes the peak hour Level of Service results at the two (2) key study intersections for existing plus project traffic conditions. The first column (I) of ICU/LOS values in Table 8-1 presents a summary of existing AM and PM peak hour traffic conditions (which were also presented in Table 3-3). The second column (2) lists existing plus project traffic conditions. The third column (3)shows the increase in ICU value due to the added peak hour Project trips and indicates whether the traffic associated with the Project will exceed the LOS thresholds defined in this report. The project-specific intersection improvement described below has been presumed as part of the evaluation of Existing Plus Project traffic conditions: ■No. 2 -Harbor Boulevard at I st Street: Widen the westbound approach of the intersection to provide an exclusive westbound right-tum lane on !st Street with 190-feet of storage. Review of Column 3 of Table 5-1 indicates that the two (2) key study intersections are forecast to operate at LOS D or better during the weekday AM and PM peak hours with the addition of Project traffic to Existing traffic conditions. Review of Columns 2 and 3 of Table 5-1 indicates that the traffic associated with the proposed Project will not require improvements at either of the two (2) key study intersections, when compared to the LOS standards and thresholds specified in this report. Appendix B presents the existing plus project ICU/LOS calculations for the two (2) key study intersections. LINSCOTT, LAW & GREENSPAN, engineers 19 LLG Ref 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit D to Exhibit 2 TABLE 5-1 ExiSTING PLUS PROJECT PEAK HOUR INTERSECTION CAPACITY ANALYSIS e ;:a (I) (2) • s"'Existing Existing Plus Project .§ c.C .s tt ...l Traffic Conditions Traffic Conditions :,q Time Key Intenection Period ICUillCM LOS ICUillCM LOS Harbor Boulevard at AM 0.719 C 0.730 C I. 5th Street D PM 0.729 C 0.733 C Harbor Boulevard at AM 0.760 C 0.765 C 2. 1st Street6 E PM 0.811 D 0.789 C � Bold ICU values indicate adverse service levels based on the Cities LOS standards. 6 A 190-foot westbOW1d ri5ht-turn pocket at the intersection ofHatborBoulevard and I"' Street will be constructed as part of the proposed Proiect. LINSCOTT, LAW & GREENSPAN, engineers 20 (J) Exceeds LOS Thresholds Increase Y-o 0.011 No 0.004 No 0.005 No -0.022 No LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Pr(!ject, Santa Ana Exhibit D to Exhibit 2 5.4 Year 2028 Traffic Conditions Table 5-2 summarizes the peak hour Level of Service results at the two (2) key study intersections for the Year 2028 horizon year. The first column (I) of ICU/LOS values in Table 5-2 presents a summary of existing AM and PM peak hour traffic conditions. The second column (2) lists projected cumulative traffic conditions (existing plus ambient plus related projects traffic) based on existing intersection geometry, but without any traffic generated from the proposed Project. The third column (3) presents forecast Year 2028 near-term traffic conditions with the addition of Project traffic. The fourth column (4) shows the increase in ICU value due to the added peak hour Project trips and indicates whether the traffic associated with the Project will exceed the LOS thresholds defined in this report. The project-specific intersection improvement described below has been presumed as part of the evaluation of Year 2028 Cumulative Plus Project traffic conditions: •No. 2 -Harbor Boulevard at 1'1 Street: Widen the westbound approach of the intersection to provide an exclusive westbound right-tum lane on 1st Street with 190-feet of storage. 5.4.1 Year 2028 Cumulative Base Traffic Conditions Review of Column 2 of Table 5-2 indicates that the two (2) key study intersections are forecast to continue to operate at acceptable levels of service (LOS D or better) during the AM and PM peak hours for Year 2028 Cumulative Base traffic conditions. 5.4.2 Year 2028 Cumulative Plus Project Conditions Review of Column 3 of Table 5-2 indicates that the two (2) key study intersections are forecast to continue to operate at acceptable levels of service (LOS D or better) during the AM and PM peak hours with the addition of Project traffic to Year 2028 Cumulative traffic conditions. Review of Columns 3 and 4 of Table 5-2 indicates that the traffic associated with the proposed Project will not require improvements at either of the two (2) key study intersections, when compared to the LOS standards and thresholds specified in this report. Appendix B also presents the near-term ICU/LOS calculations for the two (2) key study intersections. LINSCOTT, LAW & GREENSPAN, engineers 21 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N' ,4700·.21J-1737. F1rs1 Harbor \!,xed l'�e. S:inta ,\na'R�l'O' 1 47J7 Fir�\ H:u l>or \h\�d-L:'<1!, S.uua Ana Tr:iffic Study 10-2J-1J <l<1c Exhibit D to Exhibit 2 TABLE5•2 YEAR 2028 PEAK HOUR INTERSECTION CAPACITY ANALYSIS 8 .. = a r,i (I) (2) .§ �s Existing Year 2028 .5 � Traffic Conditions Traffic Conditions :q Time Key Intersection Period ICU/HCM LOS ICUillCM LOS Harbor Boulevard at AM 0.719 C 0.770 C I. 5th Street D PM 0.729 C 0.781 C Harbor Boulevard at AM 0,760 C 0.801 D 2. 1'1 Street7 E PM 0.811 D 0.864 D � Bold ICU values indicate adverse service levels based on the Cities LOS standards 7 A westbound right-b.lm pocket at the intersection ofHarborBoulevard and l" Street will be constructed as part of the proposed Project. LINSCOTT, LAW &GREENSPAN, enginer;rs (J) Year2028 Plus Project (4) Traffic Conditions Ei:ceeds LOS Thresholds ICU/HCM LOS Increase Ye,JNo 0.781 C 0,011 No 0.791 C 0.010 No 0,805 D 0.004 No 0.837 D -0.027 No LLG Ref. 2-23-4737-1 Fi Ill Harbor Mixed-Use Project, Santa Ana Exhibit D to Exhibit 2 6.0 SITE ACCESS AND INTERNAL CIRCULATION EVALUATION 6.1 Site Access Access to the Project will be provided via one (!) right-turn in/out only driveway on Harbor Boulevard and two (2) driveways restricted to left-turns/right-turns in, and right-turns out, on Figueroa Street. Table 6-1 summarizes the intersection level of service results for the three (3) proposed Project driveways under Existing and near-term (Year 2028) traffic conditions at completion and full occupancy of the proposed Project based on the HCM methodology. As shown, these Project driveways are forecast to operate at LOS D or better during the AM peak hour and PM peak hour. As such, Project access would be adequate. Motorists entering and exiting the Project site would be able to do so without undue congestion. Furthermore, the anticipated queues at each of the Project driveways are anticipated to be no more than one (I) vehicle during the AM and PM peak hours. Appendix C presents the existing and near-term HCM/LOS calculations for the three (3) Project driveways. LINSCOTT, l.Aw&GREENSPAN, engineers 23 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project. Santa Ana N· ,--1700\nH7J7 • First Harbor :,.fi��d Use. S.mta Ana1R�po1t147J7 F1rs1 !-fa l>or �11��d-Usc. S:m1.,.1 .\na Traffic Stud,· \0-23-2J do,; Exhibit D to Exhibit 2 TABLE 6-1 PROJECT DRIVEWAY PEAK HOUR INTERSECTION CAPACITY ANALYSIS Key Intersection Harbor Boulevard at A. Project Driveway No. 1 B. Figueroa Street at Project Driveway No. 2 (North) Figueroa Street at C. Project Driveway No. 3 (South) Notes· •s/v = seconds per vehicle LINSCOTT, l.Aw & GREENSPAN, engineers Intersection Time Control Period One-Way AM Stop PM One-Way AM Stop PM One-Way AM Stop PM 24 (I) (2) Existing Year2028 Plus Project Plus Project Traffic Conditions Traffic Conditions HCM LOS HCM LOS 15.4 s/v C 16.1 s/v 24.6 s/v C 27.1 s/v D 8.4 s/v A 8.4 s/v A 8.5 s/v A 8.5 s/v A 8.5 s/v A 8.5 s/v 8.6 s/v A 8.6 s/v A LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N A70(i22JHJ7 -F,m Harbor M,,.ed t:w, Sant� A11a'R�po11'4737 F11�11-for!,or M,x�d-USI!, SanL1 .\na Traffic Stud�· 1◊-2J-2�.doc Exhibit D to Exhibit 2 6.1.1 Traffic Gap Assessment To supplement the level of service analysis, a traffic gap analysis was conducted along Harbor Boulevard, as well as at the intersection of Figueroa Street at I'' Street, to determine if the existing traffic gaps along the main arterial roadways are considered adequate to accommodate egress at the proposed Project driveways. For the purposes of this study, it is assumed that the minimum time for one vehicle to complete the outbound right-tum movement and outbound left-tum movement is 7 seconds and IO seconds, respectively. These duration criteria were derived from empirical data collected by LLG from prior studies, and are considered conservative when compared against Table 405. IA of the Caltrans Highway Design Manual, which indicates a minimum of 6.5 seconds is required for a passenger vehicle to complete a right-tum from a stop, and a minimum of 8.5 seconds is required for a passenger vehicle to complete a left-tum from a stop when crossing three lanes. Table 6-2 presents a summary of the results from traffic gap observations/surveys performed in September 2023 for the westbound right-tum movement at the intersection of Harbor Boulevard at Project Driveway No. I, and the southbound right-tum movement at the intersection of Figueroa Street at I st Street. Table 6-2 indicates that based on the gap surveys, traffic gaps along northbound Harbor Boulevard and on westbound !st Street (that meet the duration criteria described previously) were observed to occur more frequently compared to the number of times a vehicle would be exiting the Project site using the driveway off Harbor Boulevard, or a vehicle exited/would be exiting from southbound Figueroa Street, to enter into/merge with the traffic stream already on Harbor Boulevard and I st Street. Based on these empirical results, it is reasonable to conclude that there would be an adequate number of available gaps in traffic to accommodate right-turning vehicles from the Project site onto Harbor Boulevard, and from southbound Figueroa Street onto westbound I st Street. Table 6-3 summarizes the results of the traffic gap analysis for the southbound left-tum movement at the intersection of Figueroa Street at 1st Street. Table 6-3 indicates that based on the gap surveys, traffic gaps along !st Street (that meet the duration criteria described previously) were observed to occur more frequently compared to the number of times a vehicle exited/would be exiting from southbound Figueroa Street to enter into/merge with the traffic stream already on I st Street. Based on these empirical results, it is reasonable to conclude that there would be an adequate number of available gaps in traffic to accommodate left-turning vehicles from southbound Figueroa Street onto eastbound I st Street. As described previously, Project-specific improvements are planned for implementation at the intersection of Harbor Boulevard and !st Street (Intersection No. 2) that were previously approved by the City. As part of those improvements, the Project will be adding a right-tum pocket (with a total length of 213 feet, comprised of 186 feet of storage length, and 27 feet of transition length) along I st Street on the westbound approach of the intersection. The additional roadway capacity on westbound 1st Street due to the provision of the future right-tum pocket could help increase the number of available traffic gaps that would facilitate southbound right-turns from Figueroa Street onto I st Street. LINSCOTT, LAW & GREENSPAN, engineers 25 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit D to Exhibit 2 TABLE 6-2 RIGHT• TURN Our VEHICLE GAP ANALYSIS Harbor Boulevard at Project Driveway No. 1 (Westbound Right-Turn) Figueroa Street at P1 Street(Southbound Right-Tum) AM Peak Hour (7AM-8AM) PM Peak Hour (SPM-6PM) AM Peak Hour (7AM -8Al\[) PM Peak Hour (5PM-6PM) Gaps Total Gaps Total Gaps Total Gaps Total Vehicles Occurring Vehicles Vehicles Occurring Vehicles Vehicles Occurring Vehicles Vehicles Occurring Vehicles Served During that could Served During that could Served During that could Served During that could Gap8 by Peak b, by .... b, by .... b, by . ... b, (seconds) Gap9 Hour!U Served11 Gap9 Hour10 Served11 Gap9 Hour10 Served11 Gap9 Hour10 Served11 " " " 7-13 I 59 59 I 45 45 I 52 52 I 17 17 14-20 2 21 42 2 24 48 2 19 38 2 9 18 21-27 3 7 21 3 16 48 3 12 36 3 I 3 :::2s 4 20 80 4 9 36 4 17 68 4 3 12 Total Vehicles that Total Vehicles that Total Vehicles that Total Vehicles that could be 202 could be 177 could be 194 could be so Accommodated by Accommodated by Accommodated by Accommodated by Traffic Gaps Traffic Gaps Traffic Gaps Traffic Gaps Total Vehicles Exiting Total Vehicles E:s:iting Total Vehicles Exiting Total Vehicles Exiting the Project11 33 the Project11 38 the Project & Figueroa 49 the Project & Figueroa 43 Streetn Street11 Adequate Traffic Yo, Adequate Traffic y., Adequate Traffic Yo, Adequate Traffic y., Gaps? Gaps? Gaps? Gaps? A gap is defined as the time interval between cars crossing the Projectdriveway/minorstreet. For puiposes of this study, it is assumed the minimum time for one vehicle to complete a turning movement out of the Project driveway is 7 seconds, which was derived from empirical data collected by LLG. Per Ta hie ./OS.IA of the Caltrans Highway Design Manual, a minimum of6.5 seconds is required for a passenger vehicle to complete a right-tum from a stop, so an assumption of7 seconds is considered conservative. Values are based on gap survey performed on Wednesday September 27, 2023. Total Vehicles that could be Served= (Number of Vehicles Served) x (Number of Gaps During Peak Hour) Total vehicles exiting is based on Year 2028 Plus Project traffic conditions traffic volumes, Although Figueroa al I" Street is not a study intersection, ex:isting counts were collected at the intersection for the purposes of this gap analysis. LINSCOTT, LAW & GREENSPAN, engineer.. ' LLG Ref. 2-23-4737-1 26 First Harbor Mixed•Use Project, Santa Ana Exhibit D to Exhibit 2 13 14 IS 16 17 TABLE6-3 LEFT. TURN Our VEHICLE GAP ANALYSIS Figueroa Street at !51 Street (Southbound Left�Turn) AM Peak Hour (7 AM -8AM) PM Peak Hour (5PM-6PM) Gaps Total Gaps Total Vehicles Occurring Vehicles Vehicles Occurring Vehicles Served During that Served During that Gap13 by Peak could be by Peak could be (seconds) Gap14 Hour15 Served16 Gapt4 Hour15 Served16 10-19 I 47 47 I 15 15 20-29 2 16 32 2 6 12 30-39 3 7 21 3 2 6 2: 40 4 4 16 4 0 0 Total Vehicles that Total Vehicles that could be 116 could be 33 Accommodated by Accommodated by Traffic Gaps Traffic Gaps Total Vehicles Exiting Total Vehicles Exiting the Project & Figueroa 28 the Project & Figueroa 20 Street17 Street17 Adequate Traffic Yes Adequate Traffic Yes Gaps? Gaps? A gap is defined as the time interval bet\Veen cars crossing the Project driveway/minor street. For purposes of this study, it is assumed the minimum time for one vehicle to complete a turning movement out of the Project driveway is 10 seconds, which was derived from empirical data collected by LLG. Per Table 405.JA of the Caltrans Highway Design Manual, a minimum of 8.5 seconds is required for a passenger vehicle to complete a left•tum from a stop when crossing three lanes, so an assumption of IO seconds is considered conseivative. Values are based on gap suivey perfonned on Wednesday September 27, 2023. Total Vehicles that could be Seived = (Number of Vehicles Seived) x (Number of Gaps During Peak Hour) Total vehicles exiting is based on Year 2028 Plus Project traffic conditions traffic volumes. Although Figueroa at I st Street is not a study intersection, existing counts were collected at the intersection for the purposes of this gap analysis. LINSCOTT, LAw& GREENSPAN, engineers 27 LLG Re£ 2-23-4737-1 First Harbor Mixed.Use Project, Santa Ana N. 1�700\11H737 -first H:ubor 1'-li��d l!�. S:mta ,\na\R�po1t'-17J7 Fust Haibor ;I.I1��d-U� Sai1L1 ,\n� Traffic StuJy 10-23-23 doc Exhibit D to Exhibit 2 6.2 Internal Circulation Evaluation Based on our review of the preliminary site plan, driveway lengths are sufficient such that access to parking spaces would not be impeded by internal vehicle queuing/stacking. Curb return radii have been confirmed and are adequate for service/delivery trucks and trash trucks. The circulation on each level of the parking structure is adequate, with sufficient sight distance along the drive aisles. 6.3 Sight Distance Evaluation At intersections and/or Project driveways, a substantially clear line of sight should be maintained between the driver of a vehicle waiting at the crossroad and the driver of an approaching vehicle. Adequate time must be provided for the waiting vehicle to either cross all lanes of through traffic, cross the nearby lanes and turn left, or turn right, without requiring through traffic to radically alter their speed. A sight distance evaluation has been performed for the three (3) Project driveways located along Harbor Boulevard and Figueroa Street, as well as the intersection of Figueroa Street and I st Street. The Sight Distance Evaluation prepared for the Project driveways is based on the criteria and procedures set forth by the California Department of Transportation (Caltrans) in the State's Highway Design Manual (HDM). Corner sight distance was utilized for the evaluation. Corner sight distance is defined in the Caltrans HDM to be the distance required by the driver of a vehicle, traveling at a given speed, to maneuver their vehicle and avoid an object without radically altering their speed. Line of sight for corner sight distance is to be determined from a 3 ½ foot height at the location of the driver of a vehicle on a minor road to a 4¼ foot object height in the center of the approaching lane of the major road. Based on the criteria set forth in Table 405.IA of the Caltrans HDM and a posted speed limit of 40 mph on Harbor Boulevard, a corner sight distance of 382 feet for right-turning vehicles is required for Project Driveway I. Based on the criteria set forth in Table 405.IA of the Caltrans HDM and a prima facie speed limit of 25 mph on Figueroa Street, a corner sight distance of239 feet is required for right-turning vehicles at Project Driveways 2 and 3. Based on the criteria set forth in Table 405.IA of the Caltrans HDM and a prima facie speed limit of 40 mph on 1 st Street, a corner sight distance of 382 feet is required for right-turning vehicles. For left-turning vehicles, a corner sight distance of 434 feet is required when looking to the left and 492 feet is required when looking to the right. Figure 6-1 presents the results of the sight distance evaluation for right-turning vehicles at Project Driveway I based on the application of the corner sight distance criteria. The figure illustrates the limited use areas. As shown, the sight lines at the proposed Project driveway are expected to be adequate as long as obstructions within the sight triangles are minimized. LINSCOTT, lAW & GREENSPAN, engineers 28 LLG Re( 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N' ,4700\2234737 -Fir�t lfarbor i\f1x�d u�e. Sant� ,\na' Repo,11�737 Fii�t l!arbm �li,.�d-Use, Sn11t.1 .\n;t Trnfiic St11dy l0-2J-2J.doc Exhibit D to Exhibit 2 Figure 6-2 presents the results of the sight distance evaluation for right-turning vehicles at Project Driveways 2 and 3 based on the application of the comer sight distance criteria. The figure illustrates the limited use areas. As shown, the sight lines at the two (2) Project driveways will be obstructed by vehicles parked on-street along Figueroa Street. Based on this, it is recommended to restrict on street parking along the segment of Figueroa Street adjoining the Project site to help facilitate traffic flows, and enhance visibility for southbound traffic on Figueroa Street and Project traffic exiting the driveways. Figures 6-3 and 6-4 present the results of the sight distance evaluation for southbound right-turning vehicles and southbound left-turning vehicles, respectively, at the intersection of Figueroa Street and 1st Street based on the application of the comer sight distance criteria. The figure illustrates the limited use areas. As shown, the sight lines for southbound right-turning and left-turning vehicles on Figueroa Street are expected to be adequate as long as obstructions within the sight triangles are minimized. LINSCOTT, LAW & GREENSPAN, engineers 29 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N A700,22J.l7J7 • Fn$1 Ha,bor \hxcd l'.Si!. Sanu -\na'R1lpo,t'H37 F1f51 Harl-or .\11).cd-\;S<e. Sant.1 .\na Tmffic Study I0-13-2J.doc Exhibit D to Exhibit 2 SIGHT DISTANCE DESIGN SPEED LIMIT: REQUIRED CORNER SIGHT DISTANCE: 40 MPH 382 FEET -., LEGEND � PUBUC RJCHT-OF-WAY I.hi/TIT) US£ ARCA· TO £NSl/l?E AD£0UATE SIGHT OISTANC£, fW?OSCAP£ ANO/OR IANOSCA/'£ SH'J.L NOT 8£ HICHER THAN JO INCHES ABO\£ TH£ CUR8/SIO€WALJ(, NO ITNC£S OR WALLS IN UMITElJ use AR£A II I f -r:;-t �, .. 1--, --'--+---u SOURCE: PRIMIOR FIGURE 6-1 HARBOR BOULEVARD SIGHT DISTANCE ANALYSIS FIRST HARBOR MIXED-USE PROJECT, SANTA ANA f Exhibit D to Exhibit 2 I� �O SCALE SIGHT DISTANCE DESIGN SPEED LIMIT: REQUIRED CORNER SIGHT DISTANCE: 25 MPH 239 FEET LEGEND � PU8UC RIGHT-OF-WA< LJMITll) US£ AR£:A: TO £NS/JR£ AIJCOllATC S/CHT DISTANCE, HAROSCAP£ ANO/OR lANOSCAff SH<l.L NOT 8£ HIGHER f>IAN JO INCH£:S ABO>!' TH£ C/JR8/SIOCWALX. NO F£:NC£:S OR WALLS IN UAIITCO /JS£ ARDl SOURCE: PRIMIOR FIGURE 6-2 FIGUEROA STREET SIGHT DISTANCE ANALYSIS FIRST HARBOR MIXED-USE PROJECT. SANTA ANA Exhibit D to Exhibit 2 SIGHT DISTANCE DESIGN SPEED UMIT: REQUIRED CORNER SIGHT DISTANCE LOOKING LETT: 40 MPH 382 FEET LEGEND � PUBUC RIGHT-OF-WAY L/1,i/TITJ US£ ARE:A.· ro ENSURE A/)£OIJA TE S!CHT OISWICC. HAROSCAPE: ANO/OR I.ANOSCAPE: SH,ILL I/OT BE: HICHE:R THAN JO INCHES ABO\£ THE CUR8/SJOEWALX. NO FENCES OR WALLS IN LIMITE:0 USE: AR£A. SOURCE: PRIMIOR FIGURE 6-3 FIGUEROA STREET AT 1ST STREET SOUTHBOUND RIGHT SIGHT DISTANCE ANALYSIS FIRST HARBOR MIXED-USE PROJECT, SANTA ANA f Exhibit D to Exhibit 2 SIGHT DISTANCE 0£SIGN SPEED Ut,UT: REQUIRED CORNER SIGHT DISTANCE L()()l(ING LEn: REQUIRED CORNER SIGHT DISTANCE LOOKING RIGHT: -J�] rt· pn .. .r;.+:;-: . -';.. : ...., ... � � . . ' . -�fl11UWI • • ' J I • 40 MPH 434 FEET 492 FEET LEGEND t7222l �'#ff �11�-�olf:1/°s,::f OISTANCC. HAROSCAP£ ANO/OR LA/VOS� 51{4LL NOT 8£ HICH£R THAN JO INCHES ABO>£ TH£ CIJRB/SIOEWAJ.J(. NO Ff:NC£S OR WALLS IN UMrTEO /JS£ AREA SOURCE: PRIMIOR FIGURE 6-4 FIGUEROA STREET AT 1ST STREET SOUTHBOUND LEFT SIGHT DISTANCE ANALYSIS FIRST HARBOR MIXED-USE PROJECT, SANTA ANA Exhibit D to Exhibit 2 7 .0 INTERSECTION TURN POCKET QUEUING ANALYSIS To validate the adequacy of stacking provided for the northbound left-turn/"U-turn" lane located at the intersection of Harbor Boulevard and 5th Street, as well as the southbound left-turn/"U-turn" lane, westbound dual left-turn lanes, and future Project-specific improvement of a westbound right turn lane located at the intersection of Harbor Boulevard and I st Street, a queuing evaluation was conducted under Existing, Existing plus Project, Year 2028 Cumulative Base and Year 2028 Cumulative plus Project traffic conditions. The Highway Capacity Manual 6th Edition (HCM 6) methodology was utilized to confirm the adequacy of vehicular stacking for the aforementioned turn lanes located at the intersections of Harbor Boulevard and 5th Street, and Harbor Boulevard and I st Street. Tables 7-1 and 7-2 present the queueing results. Existing Plus Project and Year 2028 Plus Project traffic conditions presume the Project-specific improvement (i.e., addition of an exclusive right-turn pocket on the westbound approach) at the intersection of Harbor Boulevard and I st Street. Tables 7-1 and 7-2 indicate that adequate queue storage length is currently provided for the northbound left-turn/"U-turn" lane located at the intersection of Harbor Boulevard and 5th Street based on the anticipated maximum 95th percentile queue length under Existing, Existing plus Project, Year 2028 Cumulative Base, and Year 2028 Cumulative plus Project traffic conditions. Although the existing and future 95th percentile queues reported for the southbound left-turn/"U turn" and westbound left-turn movements at the intersection of Harbor Boulevard and I st Street exceed the existing storage lengths for the respective movements, these are existing queue storage deficiencies not caused by the Project. The 95th percentile queue lengths are conservative estimates of potential queues because, given 30 signal cycles per hour (based on a cycle length of 120 seconds), the 95th percentile queue might form in only 1.5 cycles during the peak hour. It should be noted further that the Project-generated traffic that could be added to the southbound and westbound left-turn movements are nominal (i.e., southbound left-turn: 15 AM peak hour trips, 36 PM peak hour trips; westbound left-turn: 11 AM peak hour trips, 16 PM peak hour trips), corresponding to a maximum of one vehicle on a given cycle. Tables 7-1 and 7-2 indicate that adequate queue storage length would be provided for the planned westbound right-turn pocket at the intersection of Harbor Boulevard and J st Street based on the anticipated maximum 95th percentile queue length under Existing plus Project, and Year 2028 Cumulative plus Project (during the AM peak hour only) traffic conditions. Although the future 95th percentile queue length of 232 feet during the PM peak hour would exceed the proposed pocket length of 213 feet, there is an additional 27 feet of queue storage on westbound I'' Street between the end of the future right-turn pocket and Figueroa Street that would result in a total storage length of240 feet, which could accommodate the forecasted queue length of232 feet. LINSCOTT, LAw&GREENSPAN, engineers 30 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit D to Exhibit 2 Based on the considerations above, improvements are not recommended. Appendix D provides the queuing calculation worksheets for Harbor Boulevard at 5th Street and Harbor Boulevard at I st Street. LINSCOTT, LAW & GREENSPAN, engineers 31 LLG Re[ 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana :-; 47U0\223--17J7 -First fl1rbor .\.�;,.ed l'se. S:rnta Ana'Report'4737 F,,;1 Harlxir :\10,.:d-Use, Santa ,\na TrJ!fo; Stud) I 0-23-23 dDc Exhibit D to Exhibit 2 Key Intersections I. Harbor Boulevard at 5th Street Northbound Left-Tumf'U-tum" 2. Harbor Boulevard at 1•tstreet Southbound Left-Tumf'U-tum" Westbound Dual Left-Tum Future Westbound Right-Turn20 18 Source_: Google Earth. Storage Provided 18 (ft) 185" 245" 3IO' 213•21 TABLE 7-1 EXISTING PLUS PROJECT QUEUING ANALYSIS (I) Existing Traffic Conditions AM Peak Hour PM Peak Hour Max, Adequate Max. Adequate Queue19 Storage Queue19 Storage (ft.) Yes/No (ft.) Yes/No 43' Yes 113' Yes 293' No 410' No 296' Yes 332' No ------- 19 Maximum queue in feet (ft) is calculated by taking the 95"' Percentile Queue length (ft) in HCM 7. A westbound right-tum pocket at the intersection ofHaroorBoulevard and I" Street will be constructed as part of the proposed Project. 21 Based on prciposed Site Plan prepared by Primior. LINSCOTT, I.Aw & GREENsPAN, engineers 32 (2) Existing Plus Project Traffic Conditions AM Peak Hour PM Peak Hour Max. Queue19 (ft.) 54' 311' 316' 206' Adequate Storage Yes/ No Yes No No Yes Max. Adequate Queue19 Storage (ft.) Yes/No 123" Yes 493' No 394' No 213' Yes ' LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit D to Exhibit 2 TABLE 7-2 YEAR 2028 PLUS PROJECT QUEUING ANALYSIS (I) Year 2028 Traffic Conditions AM Peak Hour PM Peak Hour Storage Max. Adequate Max. Adequate Provided Queue" Storage Queuell Storage Key Intersections n (ft.) (ft.) Yes/No (ft.) Yes/No I. Harbor Boulevard at 5th Street Northbound Left-Tum/"U-tum" 185' 50' Yes 141' Yes 2. Harbor Boulevard at I st Street Southbound Left-Tumf'U-tum" 245' 306' No 484' No Westbound Dual Left-Tum 310' 316' No 382' No Future Westbound Right-Tumu 213'25 ---- Source: Google E:orth. u n Maximum queue in feet (ft) is calculated by taking the 95'" Percentile Queue length (ft) in HCM 7. 24 A westbound right-Wm pocket at the intersection of Harbor Boulevard and I" Street will be constructed as pan of the proposed Project. 25 Based on proposed Site Plan prepared by Primior. (2) Year2028 Plus Project Traffic Conditions AM Peak Hour PM Peak Hour Max. Adequate Max. Adequate QueueU Storage Queuel-' Storage (ft.) Yes/No (ft.) Yes/No 67' Yes 156' Yes 336' No 550' No 344' No 438' No NoError! 211' Yes 232' Book:mar knot defined. Error! Bookmark not defined. Although the future 95th percentile queue length of232 feet during the PM peak hour would exceed the proposed pocket lenb>th of213 feet, there is an additional 27 feet of queue storage on westbound 1• Street between the end of the future right-tum pocket and Figueroa Street that would result in a total storage length of240 feet. which oould accommodate the forecasted queue length of232 feet. LINSCOTT, LAW & GREENSPAN, engineets 33 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit D to Exhibit 2 8.0 CONGESTION MANAGEMENT PROGRAM (CMP) COMPLIANCE ASSESSMENT This analysis is consistent with the requirements and procedures outlined in the current Orange County Congestion Management Program (CMP). The CMP requires that a traffic analysis be conducted for any project generating 2,400 or more daily trips, or 1,600 or more daily trips for projects that directly access the CMP Highway System (HS). As noted in Section 4.0 of this traffic study, the proposed Project is forecast to generate approximately 1,575 daily trip-ends, and therefore, does not require a CMP traffic analysis. The CMPHS includes specific roadways, which include State Highways and Super Streets, which are now known as Smart Streets. Therefore, the CMP traffic analysis requirements relate to the potential circulation effects only on the specified CMPHS. The intersection of Harbor Boulevard and I st Street (Intersection No. 2) is a CMP intersection, which would have required evaluation if the CMP threshold was exceeded. It should be noted that the City of Santa Ana LOS criteria and evaluation identified in Section 5.0 of this report is consistent with the Orange County CMP traffic analysis guidelines. The level of service results for the intersection are summarized in Tables 5-1 and 5-2 and indicate that the proposed Project will not require improvements at this location. LINSCOTT, LAW & GREENSPAN, engineers 34 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N . ...t700'.'.?:J47J7 - F11s1 !farbor \hx,:d U,,,e. S:mta A11a'R�rt'4737 First llarbor M1A.:d-L'se. S:mtl .\n� Traffic Stu.!; 10-13-D.doc Exhibit D to Exhibit 2 9.0 ROADWAY SEGMENT EVALUATION Per City of Santa Ana requirements, this section of the report analyzes the daily operating conditions of key roadway segments within the vicinity of the proposed Project. A total of one(!) key roadway segment within the City of Santa Ana have been selected for evaluation and consist of the following locations: A.Figueroa Street, between 5th Street and I st Street (City of Santa Ana) 9.1 Roadway Link Capacities The City of Santa Ana utilizes the methodology presented in the County Master Plan of Arterial Highways (MP AH) and the City of Santa Ana Circulation Element to determine LOS midblock locations, as summarized in Table 9-1. 9.2 Roadway Link Level of Service Criteria According to the City of Santa Ana, LOS D is the minimum acceptable condition that should be maintained for roadway segments. However, the City of Santa Ana has defined exceptions to this criteria in major development areas where LOS E is considered acceptable If the daily roadway V /C ratio results in unacceptable LOS conditions, a peak hour link analysis is conducted to determine if the roadway operates at a satisfactory service level during the peak hours. LINSCOTT, LAw&GREENSPAN, engineers 35 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N \.j.700\1�34737 -First Harbor :-.riwd Us,;,. Sant� A11n1Repc>1t147J7 First lfaibor Mixcd-U5e. Santa .\na Tmffic Stl1dy 1().23.23 doc Exhibit D to Exhibit 2 TABLE 9-1 ROADWAY SEGMENT CAPACITIES AND LEVEL OF SERVICE CRITERIA" Roadway Capacities Roadway Classification Lanes LOSA LOSB LOSC LOSD LOSE LOSF Principal Arterial 8D 45,000 52,500 60,000 67,500 75,000 >75,000 Major Arterial 6D 33,900 39,400 45,000 50,600 56,300 >56,300 Primary Arterial 4D 22,500 26,300 30,000 33,800 37,500 >37,500 Secondary Arterial 4U 15,000 17,500 20,000 22,500 25,000 > 25,000 Divided Collector 2D 9,000 12,000 15,000 20,000 22,000 > 22,000 Collector 2U 7,500 8,800 10,000 11,300 12,500 >12,500 26 Source: Guidance for Administration of the Orange County Master Plan of Arterials and Highways (2017). LINSCOTT, LAW & GREENSPAN, engineers 36 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana � ,-t70011:C.Jn37 -F1rs1 H:ubor \!iwd l;si!. Santa Ana'R-,,011'.1737 First H.trl\Cr M,�cd-U,e. Sa11ta .\n� Tr:iffic Study 10-23-2..l do,: Exhibit D to Exhibit 2 9.3 Roadway Segment Analysis Results 9.3.1 Existing Plus Project Analysis Table 9-2 summarizes the results of the Existing Plus Project daily analysis for the one (1) key roadway segment. The first column (1) in Table 9-2 presents a summary of existing daily traffic conditions. The second column (2) lists existing traffic conditions with the addition of traffic generated by the proposed Project. The third column (3) indicates whether the traffic associated with the Project will exceed the level of service thresholds defined in this report. Existing Traffic Conditions Review of Column I of Table 9-2 indicates that the one (1) key roadway segment currently operates at acceptable LOS A. Existing Plus Project Traffic Conditions Review of Columns 2 and 3 of Table 9-2 indicates that the one (I) key roadway segment is forecast to continue to operate at an acceptable service level on a daily basis with the addition of Project generated traffic to existing traffic and will not require improvements when compared to the LOS standards and thresho.lds specified in this report. ltNSCOTT, I.Aw & GREENSPAN, engineers 37 LLG Ref. 2-23-4737-1 First Harbor Mixed•Use Project, Santa Ana N ·--1700'22H7J7 -F1rs1 Harbor ,\[1,-.,d u�. S:mt� ,\na'R"J:'Ort'-H37 Fim !far!'Or :-.11�.,d-t.;se. Santa ,\n:t Traffic Stud,- 10-2J-2J.WC Exhibit D to Exhibit 2 TABLE9•2 ExiSTING PLUS PROJECT ROADWAY SEGMENT LEVEL OF SERVJCE SUMMARY (1) Eiisting Min. Traffic Conditions Acceptable Roadway No. or Daily LOS u Roadwav S........,ent Jurisdiction LOS Classification Lanes Volume A.Figueroa Street, between Santa Ana D Collector 2U 903 A 5lh Street and I"' Street LINSCOTT, LAW &GREEtlSPAN, engineers 38 (2) (3) Exceeds Existing Plus Project LOS Traffic Conditions Threshold Daily LOS Yes/No Volume 1,523 A No LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana Exhibit D to Exhibit 2 9.3.2 Year 2028 Plus Project Analysis Table 9-3 summarizes the results of the Year 2028 Plus Project daily analysis for the one (I) key roadway segment. The first column (I) in Table 9-3 presents a summary of Year 2028 Cumulative daily traffic conditions. The second column (2) lists Year 2028 Cumulative traffic conditions with the addition of traffic generated by the proposed Project. The third column (3) indicates whether the traffic associated with the Project will exceed the level of service thresholds defined in this report. Year 2028 Cumulative Traffic Conditions Review of Column I of Table 9-3 indicates that the one (I) key roadway segment is forecast to operate at acceptable LOS A with the addition of ambient traffic growth and cumulative projects traffic. Year 2028· Cumulative Plus Project Traffic Conditions Review of Columns 2 and 3 of Table 9-3 indicates that the one (I) key roadway segment is forecast to continue to operate at an acceptable service level on a daily basis with the addition of Project generated traffic in the Year 2028 and will not require improvements when compared to the LOS standards and thresholds specified in this report. LINSCOTT, LAW & GREENSPAN, enginee,s 39 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana N 147Q(J\22J�7J7 - F11s1 1-farbor M1\�d L'S!!, S:mt� Ana'R�poirl,1737 F11st I fo.rbor Mt�id-l/s�. Santa An� Tr;1ffic Study 10-23-ZJ do� Exhibit D to Exhibit 2 TABLE9-3 YEAR 2028 ROADWAY SEGMENT LEVEL OF SERVICE SUMMARY (I) Year2028 Traffic Conditions Min. Acceptable Roadway No.of Daily LOS Ke--Roadwr Se-ment Jurisdiction LOS Classification Lanes Volume A Figueroa Street, between 5th Street and 151 Street Santa Ana D Collector 2U 948 A LINSCOTT, LAW & GREENSPAN, engineers 40 (2) (J) Year 2028 Exceeds Plus Project LOS Traffic Conditions Threshold Daily LOS Yes/No Volume 1,568 A No LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana Exhibit D to Exhibit 2 10.0 CEQA ASSESSMENT OF VMT, ACTIVE TRANSPORTATION, & PUBLIC TRANSIT 10.1 Vehicle Miles Traveled (VMT) Screening Analysis The purpose of this Vehicle Miles Traveled (VMT) analysis is to evaluate the Project based on Senate Bill 743 (SB 743) requirements, as required in CEQA section 15064.3. The City of Santa Ana has adopted criteria for evaluating VMT impacts under CEQA, and they are presented in the City of Santa Ana Traffic Impact Study Guidelines (September 2019). There are three types of screening methods to effectively screen projects from project-level assessment: (I) Transit Priority Area (TPA) Screening; (2) Low VMT Area Screening; (3) Project Type Screening. Projects located within a TP A may be presumed to have a less-than-significant impact on VMT absent substantial evidence to the contrary. A TPA is defined as a half-mile area around an existing "major transit stop" (i.e., a site containing an existing rail transit station, ferry terminal served by bus or rail transit service, or the intersection of two or more major bus routes with a frequency of service interval of 15 minutes or less during the morning and afternoon peak commute periods), or an existing stop along a "high-quality transit corridor" (i.e., a corridor with fixed route bus service with service intervals no longer than 15 minutes during peak commute hours). To identify if a project is in a TPA, Appendix A (Santa Ana Transit Priority Areas) of the City's guidelines is reviewed. Residential and office projects located within a low VMT-generating area may be presumed to have a less-than-significant impact absent substantial evidence to the contrary. In addition, other employment-related and mixed-use land use projects may qualify for the use of screening if the project can reasonably be expected to generate VMT per resident, per worker, or per service population that is similar to the existing land uses in the low VMT area. To identify if a project is in a TPA, Appendix B (VMT/SP in Santa Ana as Compared to Orange County Average) and Appendix C (Santa Ana Development Areas that Cannot Be Screened) of the City's guidelines are used. Some project types have been identified as having the presumption of a less-than-significant impact absent substantial evidence to the contrary because their uses are local serving in nature, including local-serving retail uses with less than 50,000 SF, and projects generating less than 110 net daily trips. Based on the application of the City's screening criteria described above, and using Appendices A, B, and C in the City's guidelines, it was determined that the Project is located in a TPA (as shown on Figure 10-1) and is located in a low-VMT generating area (as shown on Figures 10-2 and 10-3); and is therefore screened out from further VMT project-level assessment because it can be presumed to have less-than-significant impact on VMT. 10.2 Active Transportation and Public Transit Screening Analysis Even though the City's traffic impact analysis guidelines do not specify the need for Active Transportation and Public Transit Screening Analysis, potential impacts to active transportation LINSCOTT, LAw&GREENSPAN, engineers 41 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Development. Santa Ana N ,-l70DU2J47J7 -First Haib"r Mi��d t;,�. SJnta Ana'R�po1t'47J7 First H.ul'Clr )..\,��d-Fse. Santa .-\n� TrJffic Stl1dy 10-}3-23,doc Exhibit D to Exhibit 2 --OC Metrolink Rail Half Mile Buffer around Metrolink Station Half Mile around High Quality Bus Stops Santa Ana SOURCE: CITY OF SANTA ANA �O SCALE FIGURE 10-1 SANTA ANA TRANSIT PRIORITY AREAS FIRST HARBOR MIXED-USE PROJECT, SANTA ANA 9 r "! I 0 Exhibit D to Exhibit 2 Garden Grove I / Fountain Valley Costa Mesa < -15% below OC Regional Average 0 to -15% below OC Regional Average -Higher than the OC Regional Average LINSCOTT LAW & GREENSPAN engineerc; �O SCALE Tustin Santa Ana " Edinger Ave Warner Ave MacArthur Blvd Irvine fg () SOURCE: CITY OF SANTA ANA FIGURE 10-2 VMT/SP IN SANTA ANA AS COMPARED TO ORANGE COUNTY AVERAGE FIRST HARBOR MIXED-USE PROJECT, SANTA ANA ;:i 0 N I ;:i I � "'.... <ii N <O Q. 9 "' • '! N I 0 " ....".. / "' • l 2 C � :f, � ·e5 e 0 " � "...." ...... "' "'/ R .. / c Exhibit D to Exhibit 2 Santa Ana TAZ VMT/ SP not at least 15% below County Average and is not inside of a Transit Priority Area SOURCE: CITY OF SANTA ANA FIGURE 10-3 SANTA ANA DEVELOPMENT AREAS THAT CANNOT BE SCREENED FIRST HARBOR MIXED-USE PROJECT, SANTA ANA ,,, g N I ,,, N I 0 9 ! ..; I 0 Exhibit D to Exhibit 2 (pedestrian and bicycle) and public transit facilities and circulation were evaluated in this report by determining whether the Project conflicts with adopted policies, plans, or programs regarding public transit, bicycle, or pedestrian facilities, or otherwise decreases the performance or safety of such facilities. Sidewalks are provided on both sides of the street throughout most of the City. Crosswalks, pedestrian push buttons, and pedestrian indication lights are provided at all signalized intersections adjacent to the Project site. The proposed Project plans to retain this existing pedestrian infrastructure. The proposed Project will encourage walking by integrating pedestrian connections internally, as well as to nearby activities. Pedestrian circulation would be provided via existing public sidewalks along Harbor Boulevard, 1st Street, and Figueroa Street within the vicinity of the Project. The proposed Project will protect the existing sidewalk along Project frontage on these roadways. The existing sidewalk system within the Project vicinity provides direct connectivity to the existing development located along major thoroughfares. Long-term bicycle storage for the residential and retail uses will be provided in two bike rooms, totaling 96 long-term bike spaces. An additional four ( 4) bicycle spaces will be provided for short term bicycle storage purposes. According to the City of Santa Ana Bikeway Master Plan, Class IV Cycle Tracks are planned on Harbor Boulevard and I st Street along the Project's frontage. Figure 1-1 illustrates the location of public transit stops near the Project site, and Section 3.3 (Existing Public Transportation) describes the public transit-rich setting for the Project. Based on the above, the proposed Project would not have an impact on the existing multimodal network; specifically, it would not: (I) conflict with a plan, ordinance, or policy related to bicycle, pedestrian, and public transit; (2) substantially increase hazards due to a geometric design feature; or (3) result in inadequate emergency access. The proposed site plan for the Project will maintain existing sidewalks and access to public transit, construct new pedestrian connections on site and with adjoining uses, and meet City design standards regarding site access, multimodal connectivity within the internal site circulation system, emergency access, and on-site parking. LINSCOTT, LAW & GREENSPAN, engineers 42 LLG Ref. 2-23-4737-1 First Harbor Mixed.Use Development, Santa Ana N 1+700\'.'.'.'J47J7 • Firs, H,ubor Mix�d llse, Santa ,\11,1'R�1:>01t'.17J7 first I/arbor �11,ed-lisc, Santa ,\na Tr.iffic Study 10-23-23 doc Exhibit D to Exhibit 2 11.0 PARKING ANALYSIS AND PARKING MANAGEMENT PLAN {PMP) 11.1 City Code Parking Requirements City Code parking requirements for the Project were calculated based on the parking ratios from Table 3-7 (Off-Street Parking Standards) on Page 3-11 of the October 2014 Harbor Mixed Use Transit Corridor Plan for the Transit Node District. Table 11-1 presents a summary of the parking ratios applied to calculate the City Code requirements for residents, residential guests, and non residential/retail uses. As indicated on Table 11-1, the application of Specific Plan parking ratios to the various Project components results in a total City Code requirement of 313 spaces. Comparing this Code requirement against the proposed parking supply of 333 standard spaces results in a Code-based surplus of 20 spaces. Based on this, the Project's parking supply provisions would be adequate in meeting the City Code requirements for the Project. 11.2 Parking Management Plan (PMP) A PMP defines how parking for a development would be managed and what measures would be implemented to assure that parking needs in the aggregate and in localized sub-areas would be adequately served. A TOM Program identifies measures that could potentially reduce parking needs through the provision of physical and/or operational improvements that promote the use of alternative modes of travel (i.e., public transit, bicycle, walking). Recommendations for PMP measures are provided in this study to ensure competing parking needs for all Project tenants, guests, and employees are adequately managed and controlled to facilitate parking efficiency. Implementation of PMP measures will help ensure that the Project's parking supply will be sufficient, convenient/accessible, responsive to varying demand, and provide parking contingencies in meeting the parking needs of all users (i.e., residential, retail). It is recommended that when the Property Owner and/or Property Management Company deems it necessary, the following key Parking Management Strategies be implemented by the Property Owner and/or Property Management Company: •The PMP should identify where the retail/commercial employees park within the site. •The PMP should identify where location of short-term parking spaces for service retail usesand/or food uses (take-out/curb side service, etc.). •The PMP should direct residents to park in their assigned spaces and provide parking toaccommodate resident guest parking needs. •The PMP should restrict vehicles from exceeding the time restriction on any short-term parking. •The PMP should provide rules of conduct for tenants and guests to abide by. Strict enforcementshall be adhered to. LINSCOTT, LAW & GREENSPAN, engineers 43 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana N'·.4700\2234737-Firn Harbor M,x�d L'se. Santa AnJ'R�pcn'47J7 F1rs.t H�.rbor M,x�d-l's.c,, Snnt-1 Ana Tmffic Study l0-�3-23.doc Exhibit D to Exhibit 2 TABLE 11-1 CITY CODE PARKING REQUIREMENTS27 Spaces Project Description Size Code Parking Ratio Required Residential . Residents 183 DU I parking space for dwelling unit 183 Spaces . Residential Guests 183 DU 0.5 visitor spaces per dwelling unit 92 Spaces . Residential Guests 15,182 SF I parking space per 400 SF 38 Spaces Total Code Parking Requirement: 313 Spaces Proposed Parking Supply: 333 Spaces Total Parking Surplus(+) or Deficiency(-): +20 Spaces 27 Source: City of Santa Ana parking ratios from Table 3-7 (Off-Street Parking Standards) on Page 3-11 of the October 2014 Harbor Mixed Use Transit Corridor Plan for the Transit Node District LINSCOTT' LAW & GREENSPAN, engineers 44 LLG Ref 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana Exhibit D to Exhibit 2 •The PMP should adopt the mindset with the following parking goals: 1.Meet or exceed the minimum requirements for total parking spaces for the Project's retail/commercial component, as well as the residential component. 2.Provide all resident and guest parking spaces onsite. 3.Provide flexible on-site parking opportunities for commercial and resident parking that respect both commercial tenants and guest parking needs. 4.Enact policies that promote parking efficiencies and effective communication between Property Management, commercial tenants and residents. 5.Enact policies of enforcement by Property Management that are sufficiently flexible to meetcurrent and changing parking demands, while imposing penalties, if necessary. 11.3 PMP Measures The following measures are available to the Project to mitigate any parking impacts or deficiencies in the event the proposed on-site parking supply is determined to be greater than what is provided. Retail/Commercial Component 1.The Property Owner/Property Management Company will implement a reciprocal parking program to ensure the pool of parking for the retail/commercial component and guest of the residential component is available to be "shared". 2.The Property Owner/Property Management Company will work with tenants of the retail uses toimplement an employee parking program, with the goal of providing convenient and accessible shopping experience for the customers of the retail uses, and to leave the most desirable parkingspaces within the parking structure for use by customers. The location of designated employeeparking spaces will be developed in collaboration between Property Owner/PropertyManagement Company and the tenants. The employee parking spaces will be identified with awhite or yellow circle, and/or other signage recommended by the the Property Owner/PropertyManagement Company. It is noted that these spaces will be open for customer use. 3.The Property Owner/Property Management Company will work with tenants of the retail uses toidentify the need for "short term/time restricted spaces" on an as need basis, dependent on theneeds of the proposed retail and/or food use. These short-term spaces will most likely bedesignated along the internal roadways. The short-term spaces may be used for "curbside/takeout" and/or for service retail-type users. The number and location of spaces will be determinedby Property Owner/Property Management Company and the potential tenants. 4.If the Property Owner/Property Management Company determines additional parking is neededto meet the parking requirements of the retail/commercial component of the Project and/ordesires to provide "enhanced customer service", the Property Owner/Property ManagementCompany shall implement a valet/valet assist program. The hours of operation of the valet/valetassist program will be determined by the Property Owner/Property Management Company, andsubject to actual demand, may include weekdays and weekends, between the period 11 :00 AMand 2:00 PM and 5:00 PM to 10:00 PM, to enhance the customer experience accommodate the"lunch time" and "dinner" crowd of the proposed restaurant/food uses. LINSCOTT, LAW & GREENSPAN, engineers 45 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana N ,-H00'1:H7J7 • F1rs1 Hmbor Miwd u,�, S:uua �na'RcpouL-1737 F11�1 H.ulior Mt>,etl-Use. Silnta .\na TrJflic Sh1dy !O-D-23.doc Exhibit D to Exhibit 2 Residential Component 5.The Property Owner/Property Management Company shall determine the allocation of parking spaces for resident tenants and location of guest parking spaces, and assign residential parking spaces accordingly. 6.The Property Owner/Property Management Company, if deemed necessary, may allow resident guest to utilize the valet program identified in Measure No. 4, as an enhanced service. Toimplement the valet operation, the Property Owner/Property Management Company would engage the services of a well-established valet operations company similar to PMP measure No. 4. 7.Every resident will be required to register their vehicle. The registered owner must be a lease holding resident. This registration will be updated annually at the time of recertification. If valid registration is not obtained from the Property Owner/Property Management Company, the vehicle may be towed at the owners' expense. 8.Vehicles lacking current registration may be towed by the Property Owner/Property Management Company. The storage of inoperable or unregistered vehicles is prohibited. 9. If a resident obtains a new vehicle, the resident must provide new registration (transferring registration is not permissible). 10.Vehicles may not occupy unassigned spaces for more than twenty-four (24) hours, without contacting the leasing office in advance. Violators are subject to towing at the vehicle owner's expense. 1 I. Resident guests will be able to park, on a first-come-first-served basis, within the spaces designated for guest parking. 12.Violation of the PMP strategies contained herein may result in the towing of the vehicle at thevehicle owner's expense. 13.The enforcement of resident and resident guest parking on-site parking requirements summarized herein will be handled by the Property Owner/Property Management Company to ensure compliance. Retail/Commercial & Residential Component 14.To enhance efficient and comfortable movement of all users throughout the site, and access to parking spaces and valet pick-up/drop-off staging areas (if implemented), and support "Park Once" strategies, provide a detailed wayfinding/signage program that meets City standards and requirements. ltNSCOTT, LAW & GREENSPAN, engineers 46 LLG Re[ 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana Exhibit D to Exhibit 2 15.The parking conditions for the Project will be reviewed/monitored on a quarterly basis by the Property Owner/Property Management Company and appropriate actions detailed above will be taken to ensure that the necessary PMP measures are being implemented. 16.Designate areas on site for quick and efficient pick-up and drop-off of passengers to facilitate ridesharing and use of rideshare services such as Uber and Lyft. LINSCOTT, LAW & GREENSPAN, engineers 47 LLG Ref 2-23-4737-1 First Harbor Mixed•Use Development, Santa Ana Exhibit D to Exhibit 2 SUMMARY OF FINDINGS AND CONCLUSIONS •Project Description -The First Harbor Mixed-Use Project proposes to develop a nine-story building with 183 multifamily residential units (including studios, I-bedroom, 2-bedroom, and 3- bedroom units) and 15,182 SF of retail on the ground floor. Of the 183 total units proposed, 15% (28 units) would be designated as low-income housing. The residential and retail uses would wrap around a four-level parking structure, consisting of two subterranean levels, one street/ground level, and a second above-ground level, and provide a total of 333 standard parking spaces. As presented previously, Figure 1-1 is the Vicinity Map, which shows the general location of the Project and surrounding street system. Figure 2-1 is an existing aerial photograph of the Project site. The Project is expected to be completed and fully occupied by Year 2028. As part of the Project-specific improvements planned at the intersection of Harbor Boulevardand !st Street (Intersection No. 2) previously approved by the City, the Project will be adding aright-turn pocket (with a total length of213 feet, comprised of 186 feet of storage length, and 27feet of transition length) along I st Street on the westbound approach of the intersection. •Study Scope -The following two (2) key study intersections and one (I) key roadway segmentwere selected for detailed peak hour level of service analyses under Existing Traffic Conditions,Existing Plus Project Traffic Conditions, Year 2028 Cumulative Traffic Conditions and Year2028 Cumulative plus Project. Kev Study Intersections 1.Harbor Boulevard at 5th Street (City of Santa Ana)2.Harbor Boulevard at I st Street (City of Santa Ana) Kev Roadway Segments A.Figueroa Street, between 5th Street and I st Street (City of Santa Ana) •Existing Traffic Conditions -All key study intersections currently operate at an acceptable levelof service (LOS) during the AM and PM peak hours when compared to the LOS criteria definedin this report. •Project Trip Generation -The proposed Project is forecast to generate approximately 1,575daily trips, with 100 trips (36 inbound, 64 outbound) produced in the AM peak hour and 131trips (73 inbound, 58 outbound) produced in the PM peak hour on a "typical" weekday. •Related Projects Traffic Characteristics -Ten (10) related projects were considered as part ofthe cumulative background setting. The ten (10) related projects are forecast to generate 4,705 daily trips, with 245 trips (103 inbound, 142 outbound) anticipated during the AM peak hour and287 trips (162 inbound, 125 outbound) produced during the PM peak hour. LINSCOTT, LAW & GREENSPAN, engineers 48 LLG Ref 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana :>: . .4700 �13HJ7 -Fitsr Harbor ;l,li>..:d t·se, S:uua Ana R�µorrHJ7 Fir.<t Ha.rl>or \h>..:d-Llse. Santa .-\na Tr�ffic $1uJ} I0-23-23 doc Exhibit D to Exhibit 2 •Existing Plus Project Traffic Conditions -The traffic associated with the proposed Project willnot require improvements at any of the two (2) key study intersections, when compared to theLOS standards and thresholds specified in this report. The two (2) key study intersections areforecast to operate at LOS D or better during the weekday AM and PM peak hours with theaddition of Project traffic. •Year 2028 Cumulative Traffic Conditions Plus Project -The traffic associated with theproposed Project will not require improvements at any of the two (2) key study intersections,when compared to the LOS standards and thresholds specified in this report. The two (2) keystudy intersections are forecast to continue to operate at acceptable levels of service (LOS D orbetter) during the AM and PM peak hours with the addition of Project traffic to Year 2028Cumulative traffic conditions. ■ Site Access Assessment -Harbor Boulevard at Project Driveway I and Figueroa Street at ProjectDriveways 2 and 3 are forecast to operate at LOS D or better during the AM peak hour and PMpeak hour. As such, Project access will be adequate. Motorists entering and exiting the Projectsite will be able to do so without undue congestion. Furthermore, the anticipated queues at eachof the Project driveways are anticipated to be no more than one (I) vehicle during the AM andPM peak hours. To supplement the level of service analysis, a gap analysis has been completed along Harbor Boulevard as well as at the intersection of Figueroa Street at I st Street to determine if the existing gaps along the main arterial roadways are considered adequate to accommodate ingress and egress at the proposed Project driveways. The gap analysis indicates that there are more gaps than vehicles exiting, therefore, it can be concluded that both right-turning and left-turning vehicles will have adequate gaps along Harbor Boulevard and/or I st Street when exiting the Project site. •Sight Distance Evaluation -Sight lines for the southbound movements at the intersection ofFigueroa Street at l't Street, as well as at Project Driveway 1, along Harbor Boulevard, areexpected to be adequate. Sight lines at Project Driveways 2 and 3, along Figueroa Street, will beobstructed by vehicles parked on-street along Figueroa Street. As a result, it is recommended torestrict on-street parking along the Project frontage of Figueroa Street to help facilitate andenhance visibility for outbound vehicles. •Queuing Assessment -Adequate queue storage length is currently provided for the northboundleft-turn/"U-turn" lane located at the intersection of Harbor Boulevard and 5t h Street based on theanticipated maximum 95th percentile queue length under Existing, Existing plus Project, Year2028 Cumulative and Year 2028 Cumulative plus Project traffic conditions. Although the existing and future 95th percentile queues reported for the southbound left-turn/"U turn" and westbound left-turn movements at the intersection of Harbor Boulevard and 1 st Street exceed the existing storage lengths for the respective movements, these are existing queue storage deficiencies not caused by the Project. The 95th percentile queue lengths are LINSCOTT, LJ\w&GREENSPAN, engineers 49 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana I< ,-1700t:!1j 1737 -First H:1rbo1 \li>.ed l 'se. San\3 Ana·RcporH737 Fir;t H.ll l,or \(v.,:d.t:se. Sant:i .\ria Tr;iffic Study ID-23-2J doc Exhibit D to Exhibit 2 conservative estimates of potential queues. It should be noted further that the Project-generated traffic that could be added to the southbound and westbound left-tum movements are nominal (i.e., southbound left-tum: 15 AM peak hour trips, 36 PM peak hour trips; westbound left-tum: 11 AM peak hour trips, 16 PM peak hour trips), corresponding to a maximum of one vehicle on a given cycle. Adequate queue storage length would be provided for the planned westbound right-tum pocket at the intersection of Harbor Boulevard and I st Street based on the anticipated maximum 95th percentile queue length under Existing plus Project, and Year 2028 Cumulative plus Project (during the AM peak hour only) traffic conditions. Although the future 95th percentile queue length of 232 feet during the PM peak hour would exceed the proposed pocket length of 213 feet, there is an additional 27 feet of queue storage on westbound I st Street between the end of the future right-tum pocket and Figueroa Street that would result in a total storage length of 240 feet, which could accommodate the forecasted queue length of 232 feet. Based on the considerations above, improvements are not recommended. ■Existing Plus Project Roadway Segment Evaluation -The roadway segment at Figueroa Street,between 5th Street and I st Street is forecast to continue to operate at an acceptable service levelon a daily basis with the addition of Project generated traffic to existing traffic and will not require improvements when compared to the LOS standards and thresholds specified in thisreport. •Year 2028 Cumulative Plus Project Roadway Segment Evaluation -The roadway segment atFigueroa Street, between 5th Street and I st Street is forecast to continue to operate at anacceptable service level on a daily basis with the addition of Project generated traffic in the Year2028 and will not require improvements when compared to the LOS standards and thresholdsspecified in this report. •VMT Screening Assessment -Based on the application of the City's screening criteria, andusing Appendices A, B, and C in the City's guidelines, it was determined that the Project islocated in a TP A and is in a low-VMT generating area; and is therefore screened out from furtherVMT project-level assessment because it can be presumed to have less-than-significant impactonVMT. ■Parking Analysis and PMP -The application of Specific Plan parking ratios to the variousProject components results in a total City Code requirement of 313 spaces. Comparing this Coderequirement against the proposed parking supply of 333 standard spaces results in a Code-based surplus of 20 spaces. Based on this, the Project's parking supply provisions would be adequatein meeting the City Code requirements for the Project. LINSCOTT, LAW & GREENSPAN, engineers 50 LLG Ref 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana K.,.t70011'.::H737 -F,rsc Harbor \11,�d u�. S:111u ,\na··R�port�HJ7 Fnst HarlXlr �lix�d-l'�-S:mu .\n� Traffi� StuJ; l0-:?.3-2J.doc Exhibit D to Exhibit 2 Recommendations for PMP measures are provided in this study to ensure competing parking needs for all Project tenants, guests, and employees are adequately managed and controlled to facilitate parking efficiency. LINSCOTT, LAW & GREENSPAN, engineers 51 LLG Ref 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana \' -1700\�234737 -First Harbor \.��,:<I Cs.,;,. Santst AnJ\R�p,:m'47J7 First !-1:u·lxir M1�cd-l'.s.!. Santa .\n:i Tr�flic Study 10-2J-2J do� Exhibit D to Exhibit 2 . SPR No. 2024-01 & TTM No. 2024-01 for First Harbor Mixed-Use Development 101 N. Harbor Blvd Exhibit 3 - Vicinity Zoning & Aerial View Zoning 400 feet SPR No. 2024-01 & TTM No. 2024-01 for First Harbor Mixed-Use Development 101 N. Harbor Blvd Exhibit 4 – Site Photo Exhibit 5 Exhibit 5 GROUND LEVEL ANALYSISExhibit 6 PROFESSIONAL STAMP PROPERTY LINE N 89° 30' 07" W 237.98'T PARKING STALL LEGENDDRIVE AISLE T ESTAIR #3 STAIR #2TRASH #1T TENTRYELECTRICALREC FW ENTRYRECTTREC 7RECTRASH #2FW ELEV.#3 10 10 ELEV.#2 3-BED3-A1 NOTESRETAIL SPACE 1,729 SF.12 41-BED1-C1RETAIL SPACE RETAIL SPACE RETAIL SPACE RETAIL SPACE RETAIL SPACE 973 SF.STAIR #2A 31-BED1-B1908 SF. 8 2 3-BED3-A11,729 SF.11-BED1-C1973 SF.GATELOADINGLOADING RETAIL ENTRY(15,182 SF.) RETAIL SPACE MAILLEASING RETAIL SPACE RETAIL SPACE RETAIL SPACESTAIR #1 LEASING ELEV.#1 PROPERTY LINE N 89° 27' 42" W 196.01' W. FIRST STREETCL DATE:07/26/2022DRAWN BY:CNM North SHEET NUMBER:SITE PLAN A1.0THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF PRIMIOR INC.ALL DESIGNS AND OTHER INFORMATION ON THE DRAWINGS ARE FOR THE USE ON THE SPECIFIED PROJECT AND SHALL NOT BE USED OTHERWISE WITHOUT EXPRESS WRITTEN PRIMIOR INC.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE SHALL BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS. SHOP DETAILS SHALL BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING. COPYRIGHTED Exhibit 6 2ND FLOOR AT GROUND LEVEL ANALYSIS: 3 2 PROFESSIONAL STAMP PROPERTY LINE N 89° 30' 07" W 237.98'T DRIVE AISLE ENTRYSTAIR #3 STAIR #2TRASH #1T ENTRYTELECTRICALFIREREC FW RECTTRECRECTRASH #2FW ELEV.#3 10 10 ELEV.#2 3-BED3-A12ND FLR. RETAIL SPACE(1,189 SF.)12 1-BED1-C1RETAIL SPACE(1,026 SF.) 2ND FLR.STAIR #2A 1-BED1-B12ND FLR. 8RETAIL SPACE(1,026 SF.) RETAIL SPACE(1,026 SF.)3-BED3-A12ND FLR.RETAIL SPACE(1,026 SF.)1-BED1-C12ND FLR.GATERETAIL SPACE(1,026 SF.)LOADING LOADING ENTRY RETAIL SPACE(3,025 SF.) MAILLEASING RETAIL SPACE(1,111 SF.) RETAIL SPACE(1,110 SF.) RETAIL SPACE(2,839 SF.)STAIR #1LEASINGELEV.#1 PROPERTY LINE N 89° 27' 42" W 196.01' W. FIRST STREETL DATE:07/26/2022DRAWN BY:CNM North SHEET NUMBER:2ND FLOOR PLAN (GROUND LEVEL) A1.1THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF PRIMIOR INC.ALL DESIGNS AND OTHER INFORMATION ON THE DRAWINGS ARE FOR THE USE ON THE SPECIFIED PROJECT AND SHALL NOT BE USED OTHERWISE WITHOUT EXPRESS WRITTEN PRIMIOR INC.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE SHALL BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS. SHOP DETAILS SHALL BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING. COPYRIGHTED Exhibit 6 1ST SUBTERRANEAN LEVEL ANALYSIS:PROPERTY LINE N 89° 30' 07" W 237.98' PARKING STALL LEGEND PROFESSIONAL STAMP T ESTAIR #3UPDN DN UP 17 17 2ELEV.#32 ELEV.#23 ELEV.LOBBY ELEV.LOBBY STOR.STOR.STAIR #2DNUP1313 STOR. STOR. UP DN 11 STOR. STOR. STOR. RACKETBALLCOURTSTOR. STOR. STOR. STOR. 5 STOR. STOR. 2 110ELEV.LOBBY 5STAIR #1UPDN ELEV.#1 DN UP PROPERTY LINE N 89° 27' 42" W 196.01'DATE:07/26/2022DRAWN BY:CNM North SHEET NUMBER:1st SUBLEVEL PLAN (PARKING) A1.2THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF PRIMIOR INC.ALL DESIGNS AND OTHER INFORMATION ON THE DRAWINGS ARE FOR THE USE ON THE SPECIFIED PROJECT AND SHALL NOT BE USED OTHERWISE WITHOUT EXPRESS WRITTEN PRIMIOR INC.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE SHALL BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS. SHOP DETAILS SHALL BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING. COPYRIGHTED Exhibit 6 2ND SUBTERRANEAN LEVEL ANALYSIS:PROPERTY LINE N 89° 30' 07" W 237.98' PARKING STALL LEGEND PROFESSIONAL STAMPMACHINE#3 T ESTAIR #3UPDN UP 17 17 2ELEV.#32 ELEV.#23 ELEV.LOBBY ELEV.LOBBY MACHINE#2 STOR.STAIR #2UP1313UPDN 11 STOR. STOR. RACKETBALLCOURTSTOR. STOR. STOR. STOR. 5 STOR. STOR. 2 19ELEV.LOBBY 5STAIR #1STOR.UP MACHINE#1 ELEV.#1 DN UP PROPERTY LINE N 89° 27' 42" W 196.01'DATE:07/26/2022DRAWN BY:CNM North SHEET NUMBER:2nd SUB LEVEL PLAN (PARKING) A1.3THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF PRIMIOR INC.ALL DESIGNS AND OTHER INFORMATION ON THE DRAWINGS ARE FOR THE USE ON THE SPECIFIED PROJECT AND SHALL NOT BE USED OTHERWISE WITHOUT EXPRESS WRITTEN PRIMIOR INC.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE SHALL BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS. SHOP DETAILS SHALL BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING. COPYRIGHTED Exhibit 6 2ND LEVEL ANALYSIS:PROPERTY LINE N 89° 30' 07" W 237.98' PARKING STALL LEGEND PROFESSIONAL STAMP T ESTAIR #3 STAIR #2DNDN UP UP STOR. STOR. ELEV.#2ELEV.#323 15 15ELEV.LOBBY ELEV.LOBBY 13 13 13 STOR. STOR. STOR. STOR. STOR. STOR. 5 STOR. STOR. 2 1 STAIR #110ELEV.LOBBY 5UP ELEV.#1 DN PROPERTY LINE N 89° 27' 42" W 196.01'DATE:07/26/2022DRAWN BY:CNM North SHEET NUMBER:2ND LEVEL PLAN (PARKING) A1.4THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF PRIMIOR INC.ALL DESIGNS AND OTHER INFORMATION ON THE DRAWINGS ARE FOR THE USE ON THE SPECIFIED PROJECT AND SHALL NOT BE USED OTHERWISE WITHOUT EXPRESS WRITTEN PRIMIOR INC.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE SHALL BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS. SHOP DETAILS SHALL BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING. COPYRIGHTED Exhibit 6 3RD LEVEL (1ST RESI. ANALYSIS: PROPERTY LINE N 89° 30' 07" W 237.98' PROFESSIONAL STAMP STAIR #3 STAIR #215 2-BED2-C1,433SF. TRASH 141-BED1-F699 SF. 1 DNLOUNGEELEV.#3 ELEV.#23-BED3-B 1-BED1-E 16 ELEV.LOBBY ELEV.LOBBY UP1,359 SF.667 SF.STUDIOS-1517 SF.24 1-BED1-E 17 13667 SF.STUDIOS-12 2-BED2-D1,514 SF. 517 SF.23 22 1-BED1-E667 SF. 2-BED2-A967 SF. 18UPOPEN AREA /PUBLIC SPACE(9,606 SF.) 2-BED2-A 12967 SF.DN 1-BED1-E667 SF. 193 2-BED2-D1,514 SF.2-BED2-A 21967 SF.2-BED2-A967 SF. 20 1-BED1-E667 SF. HOUSEKEEPING/MAINTENANCE 11LAUNDRY4LOUNGE 3-BED3-C1,438 SF. MEN'S LOCKER ROOM 2-BED2-A967 SF. WELLNESS CENTERSOCIAL WOMEN'S LOCKER ROOM2-BED2-B1,461 SF.ELEV.LOBBY STAIR #11-BED1-E667 SF. 1-BED 1-BED1-E 1-E667 SF. 667 SF. 1-BED1-G829 SF. DN 2-BED2-B UP ELEV.#1 1,461 SF.DN UP5678 9 PROPERTY LINE N 89° 27' 42" W 196.01'DATE:07/26/2022DRAWN BY:CNM North SHEET NUMBER:3RD LEVEL PLAN (1ST RESIDENTIAL) A1.5THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF PRIMIOR INC.ALL DESIGNS AND OTHER INFORMATION ON THE DRAWINGS ARE FOR THE USE ON THE SPECIFIED PROJECT AND SHALL NOT BE USED OTHERWISE WITHOUT EXPRESS WRITTEN PRIMIOR INC.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE SHALL BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS. SHOP DETAILS SHALL BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING. COPYRIGHTED Exhibit 6 4TH LEVEL (2ND RESI.) ANALYSIS: PROFESSIONAL STAMPSTAIR #3 STAIR #215 2-BED2-C1,433SF. TRASH 141-BED1-J775 SF. 1 LOUNGE ELEV.#3 ELEV.#23-BED3-B 16ELEV.LOBBY1,359 SF.1-BED1-H749 SF. STUDIOS-1517 SF. 24 OPEN AREA / PUBLIC SPACE BELOW 1-BED1-E 17 13667 SF.STUDIOS-12 2-BED2-D1,514 SF. 517 SF.23 22 1-BED1-E667 SF. 2-BED2-A967 SF. 18 19 20 2-BED2-A967 SF. 12 1-BED1-E667 SF. 3 2-BED2-D1,514 SF.2-BED2-A967 SF. 21 2-BED2-A967 SF. 1-BED1-E667 SF. HOUSEKEEPING/MAINTENANCE 11LAUNDRY4LOUNGE 3-BED3-C1,438 SF. 2-BED2-A967 SF. 253-BED3-D1,465 SF.CARD ROOM GAME ROOM 2-BED2-B 101,461 SF.ELEV.LOBBY STAIR #11-BED1-E667 SF. 1-BED 1-BED 1-BED1-G829 SF. 1-E 1-E DN 2-BED2-B UP667 SF. 667 SF.ELEV.#1 1,461 SF.DN UP5678 9 DATE:07/26/2022DRAWN BY:CNM North SHEET NUMBER:4TH LEVEL PLAN (2ND RESIDENTIAL) A1.6THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF PRIMIOR INC.ALL DESIGNS AND OTHER INFORMATION ON THE DRAWINGS ARE FOR THE USE ON THE SPECIFIED PROJECT AND SHALL NOT BE USED OTHERWISE WITHOUT EXPRESS WRITTEN PRIMIOR INC.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE SHALL BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS. SHOP DETAILS SHALL BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING. COPYRIGHTED Exhibit 6 5TH LEVEL (3RD RESI.) ANALYSIS: PROFESSIONAL STAMPSTAIR #3 STAIR #216 TRASH 15STUDIOS-21-BED1-J775 SF. 1 514 SF.LOUNGE ELEV.#2ELEV.#33-BED3-B1,359 SF. 1417STUDIOS-3ELEV.LOBBY 1-BED1-H749 SF. STUDIO 557 SF.S-1517 SF.26 OPEN AREA / PUBLIC SPACE BELOW 1-BED1-E 18 13667 SF.STUDIOS-1 2-BED2-E1,393 SF. 2 517 SF.25 241-BED1-E667 SF. 1-BED1-E667 SF. 2-BED2-A967 SF. 19 12 1-BED1-E667 SF. 1-BED1-E667 SF. 203 2-BED2-E1,393 SF.2-BED2-A967 SF. 23 22 1-BED1-E 21 1-BED1-E667 SF. HOUSEKEEPING/MAINTENANCE 11LAUNDRY667 SF.4 LOUNGE 3-BED3-C1,438 SF. 2-BED2-A967 SF. 273-BED3-D1,465 SF.OFFICESOFFICE AREA 2-BED2-B 101,461 SF.STAIR #11-BED1-E667 SF. 1-BED 1-BED 1-BED1-G829 SF. DN1-E 1-E UP 2-BED2-B 677 SF. 677 SF.ELEV.#1 UP 1,461 SF.DN5678 9 DATE:07/26/2022DRAWN BY:CNM North SHEET NUMBER:5TH LEVEL PLAN (3RD RESIDENTIAL) A1.7THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF PRIMIOR INC.ALL DESIGNS AND OTHER INFORMATION ON THE DRAWINGS ARE FOR THE USE ON THE SPECIFIED PROJECT AND SHALL NOT BE USED OTHERWISE WITHOUT EXPRESS WRITTEN PRIMIOR INC.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE SHALL BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS. SHOP DETAILS SHALL BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING. COPYRIGHTED Exhibit 6 6TH LEVEL (4TH RESIDENTIAL) ANALYSIS: PROFESSIONAL STAMPSTAIR #3 STAIR #216 TRASH 15STUDIOS-21-BED1-J775 SF. 1 514 SF.LOUNGE ELEV.#2ELEV.#33-BED3-B1,359 SF. 1417STUDIOS-3ELEV.LOBBY 1-BED1-H749 SF. STUDIO 557 SF.S-1517 SF.26 OPEN AREA / PUBLIC SPACE BELOW 1-BED1-E 18 13667 SF.STUDIOS-1 2-BED2-E1,393 SF. 2 517 SF.25 241-BED1-E667 SF. 1-BED1-E667 SF. 2-BED2-A967 SF. 19 12 1-BED1-E667 SF. 1-BED1-E667 SF. 203 2-BED2-E1,393 SF.2-BED2-A967 SF. 23 22 1-BED1-E 21 1-BED1-E667 SF. HOUSEKEEPING/MAINTENANCE 11LAUNDRY667 SF.4 LOUNGE 3-BED3-C1,438 SF. 2-BED2-A967 SF. 273-BED3-D1,465 SF.THEATER #1 THEATER #2 THEATER #3 2-BED2-B 101,461 SF.STAIR #11-BED1-E667 SF. 1-BED 1-BED 1-BED1-G829 SF. DN1-E 1-E UP 2-BED2-B 667 SF. 667 SF.ELEV.#1 UP 1,461 SF.DN5678 9 DATE:07/26/2022DRAWN BY:CNM North SHEET NUMBER:6TH LEVEL PLAN (4TH RESIDENTIAL) A1.8THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF PRIMIOR INC.ALL DESIGNS AND OTHER INFORMATION ON THE DRAWINGS ARE FOR THE USE ON THE SPECIFIED PROJECT AND SHALL NOT BE USED OTHERWISE WITHOUT EXPRESS WRITTEN PRIMIOR INC.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE SHALL BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS. SHOP DETAILS SHALL BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING. COPYRIGHTED Exhibit 6 7TH LEVEL (5TH RESIDENTIAL) ANALYSIS: PROFESSIONAL STAMPSTAIR #3 STAIR #216 TRASH 15STUDIOS-21-BED1-J775 SF. 1 514 SF.LOUNGE ELEV.#2ELEV.#33-BED3-B1,359 SF. 1417STUDIOS-3ELEV.LOBBY 1-BED1-H749 SF. STUDIO 557 SF.S-1517 SF.26 OPEN AREA / PUBLIC SPACE BELOW 1-BED1-E 18 13667 SF.STUDIOS-1 2-BED2-E1,393 SF. 2 517 SF.25 241-BED1-E667 SF. 1-BED1-E667 SF. 2-BED2-A967 SF. 19 12 1-BED1-E667 SF. 1-BED1-E667 SF. 203 2-BED2-E1,393 SF.2-BED2-A967 SF. 23 22 1-BED1-E 21 1-BED1-E667 SF. HOUSEKEEPING/MAINTENANCE 11LAUNDRY667 SF.4 LOUNGE 3-BED3-C1,438 SF. 2-BED2-A967 SF. 273-BED3-D1,465 SF.GAMING #1 GAMING #2 GAMING #3 2-BED2-B 101,461 SF.STAIR #11-BED1-E667 SF. 1-BED 1-BED 1-BED1-G829 SF. 1-E 1-E 2-BED2-B 667 SF. 667 SF.ELEV.#1 1,461 SF.5 6 7 8 9 DATE:07/26/2022DRAWN BY:CNM North SHEET NUMBER:7TH LEVEL PLAN (5TH RESIDENTIAL) A1.9THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF PRIMIOR INC.ALL DESIGNS AND OTHER INFORMATION ON THE DRAWINGS ARE FOR THE USE ON THE SPECIFIED PROJECT AND SHALL NOT BE USED OTHERWISE WITHOUT EXPRESS WRITTEN PRIMIOR INC.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE SHALL BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS. SHOP DETAILS SHALL BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING. COPYRIGHTED Exhibit 6 8TH LEVEL (6TH RESI.) ANALYSIS: PROFESSIONAL STAMPSTAIR #3 STAIR #213 1-BED1-K1,126 SF. TRASH 1-BED1-J861 SF. 1 LOUNGE ELEV.#2ELEV.#3 12 3-BED3-B 141,359 SF.1-BED1-H829 SF. STUDIOS-1517 SF.23 OPEN AREA / PUBLIC SPACE BELOW 1-BED1-E 15 11667 SF.STUDIOS-1 2-BED2-F1,294 SF. 2 517 SF.22 211-BED1-E667 SF. 1-BED1-E667 SF. 2-BED2-A967 SF. 16 10 1-BED1-E667 SF. 1-BED1-E667 SF. 173 2-BED2-F1,294 SF.2-BED2-A967 SF. 20 191-BED1-E 18 1-BED1-E667 SF. HOUSEKEEPING/MAINTENANCE 9LAUNDRY667 SF.4 LOUNGE 3-BED3-C1,438 SF. 2-BED2-A967 SF.POOL EQUIPMENT ROOMLIBRARY #1 LIBRARY #2 2-BED2-B 81,461 SF.STAIR #11-BED1-E667 SF. 1-BED1-G829 SF. DNUP 2-BED2-B ELEV.#1 UP 1,461 SF.DN56 7 DATE:07/26/2022DRAWN BY:CNM North SHEET NUMBER:8TH LEVEL PLAN (6TH RESIDENTIAL)A1.10THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF PRIMIOR INC.ALL DESIGNS AND OTHER INFORMATION ON THE DRAWINGS ARE FOR THE USE ON THE SPECIFIED PROJECT AND SHALL NOT BE USED OTHERWISE WITHOUT EXPRESS WRITTEN PRIMIOR INC.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE SHALL BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS. SHOP DETAILS SHALL BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING. COPYRIGHTED Exhibit 6 9TH LEVEL (7TH RESI.) ANALYSIS: PROFESSIONAL STAMPSTAIR #3 STAIR #213 1-BED1-K1,036 SF. TRASH 1-BED1-J775 SF. 1 LOUNGE ELEV.#2ELEV.#3 12 3-BED3-B 141,359 SF.1-BED1-H749 SF. STUDIOS-1517 SF.23 OPEN AREA / PUBLIC SPACE BELOW 1-BED1-E 15 11667 SF.STUDIOS-1 2-BED2-F1,228 SF. 2 517 SF.22 211-BED1-E667 SF. 1-BED1-E667 SF. 2-BED2-A967 SF. 16 10 1-BED1-E667 SF. 1-BED1-E667 SF. 173 2-BED2-F1,228 SF.2-BED2-A967 SF. 20 191-BED1-E 18 1-BED1-E667 SF. HOUSEKEEPING/MAINTENANCE 9LAUNDRY667 SF.4 LOUNGE 3-BED3-C1,438 SF. 2-BED2-A967 SF.MENS WOMENS COFFEE LOUNGESHOWER 2-BED2-B1,461 SF. 820'x31' POOL 20'x9'-6" SPA STUDIOS-4674 SF. STAIR #1 1-BED1-G829 SF. DNUP 2-BED2-B1,461 SF. ELEV.#1 DN UP56 7 DATE:07/26/2022DRAWN BY:CNM North SHEET NUMBER:9TH LEVEL PLAN (7TH RESIDENTIAL)A1.11THESE DRAWINGS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF PRIMIOR INC.ALL DESIGNS AND OTHER INFORMATION ON THE DRAWINGS ARE FOR THE USE ON THE SPECIFIED PROJECT AND SHALL NOT BE USED OTHERWISE WITHOUT EXPRESS WRITTEN PRIMIOR INC.WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.CONTRACTORS SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE SHALL BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS. SHOP DETAILS SHALL BE SUBMITTED TO THIS OFFICE FOR REVIEW BEFORE PROCEEDING. COPYRIGHTED VIEW AT FIRST & HARBOR INTERSECTION FIRST & HARBOR RESIDENCES | JANUARY 2024 2 Exhibit 7 VIEW SOUTH AT HARBOR BOULEVARD FIRST & HARBOR RESIDENCES | JANUARY 2024 3 Exhibit 7 VIEW AT FIGUEROA STREET FIRST & HARBOR RESIDENCES | JANUARY 2024 4 Exhibit 7 VIEW SOUTH AT FIGUEROA STREET FIRST & HARBOR RESIDENCES | JANUARY 2024 5 Exhibit 7 VIEW AT FIGUEROA STREET RESIDENCES FIRST & HARBOR RESIDENCES | JANUARY 2024 6 Exhibit 7 VIEW AT LEVEL 03 PUBLIC PARK FIRST & HARBOR RESIDENCES | JANUARY 2024 7 Exhibit 7 VIEW AT LEVEL 09 POOL DECK FIRST & HARBOR RESIDENCES | JANUARY 2024 12 Exhibit 7 VIEW AT FIRST STREET SOUTH ELEVATION FIRST & HARBOR RESIDENCES | JANUARY 2024 13 Exhibit 7 VIEW AT FIGUEROA STREET EAST ELEVATION FIRST & HARBOR RESIDENCES | JANUARY 2024 15 Exhibit 7 MATERIAL FINISHES EXTERIOR GL-1 / GL-3 LAMINATED VISION GLAZING, LOW IRON, LOW-E COATING GL-2 SHADOW BOX SPANDREL, LOW IRON, LOW-E COATING Typical Unit Glazing, Corridors, Lobby & Retail Frontage, Office, Meeting Rooms BOH Areas, Meeting rooms, pool enclosure PL-1STUCCO, TEXTURED, INTEGRAL WHITE COLOR Field PL-2STUCCO, TEXTURED, INTEGRAL GRAY COLOR Field WD-1 TRESPA METEON DECORS ENGLISH CHERRY Balcony Ceilings / Level 01 unit exterior wall cladding CON-1CAST-IN-PLACE CONCRETE, TEXTURED, SEALED Parking Garage CP-1 COMPOSITE CLADDING, TRESPA METEON METALLICS Architectural feature, frame elements throughout Stair Exterior Features MTL-1ALUMINUM, BLACK, SATIN FINISH Storefront mullions throughout CP-2 / CP-3 COMPOSITE CLADDING, TRESPA METEON METALLICS Balcony Slab Edge Features / Decorative Architectural Louver Features PL-3STUCCO, TEXTURED, INTEGRAL TAUPE COLOR CP-1 GL-1 PL-1 CP-2 GL-1 GL-2 PL-1 PL-2 PL-3 GL-3 CP-1 CP-2 CP-3 WD-1 CON-1 MTL-1 GL-3PL-3 WD-1 PL-3 PL-2 CP-2 CP-3 MTL-1 BR-1 WD-1 GL-2 Storefront walls, Parking Garage ST-1MANUFACTURED STONE IDAHO DRYSTACK Low walls at residential ground level BR-1BELGIAN BRICK BEAR CREEK BR-1 ST-1 ST-1BR-1 FIRST & HARBOR RESIDENCES | JANUARY 2024 21 Exhibit 7 ii .. i' z I I I I '" I I I ' I ' 1 ' TENTATIVE TRACT MAP NO. 1927 4 FOR CONOOMNUM PUAPOSES LEGEND Cl<._..,----� .,..,.,, ' :--=, = J..0:.,/«l-• • (<_ , -----�M�-�--�� ::--�··�� �ff "'J -=" t, I <.!!. CITY OF SANTA mA. COUNTY OF ORANGE, STATE OF CALFOANA 'l!l!Cll(U(; ... , '9l:1'01tOIOl1Cf _.I\ICK!IC%0ml,001r') Ul!ilfl<.,-...,lr.JUI i t ' s ' -' '�J'""'i.1 �! .,, I ( I" (d:l,O,IUIIC {11.-JtllClltk\t- L ar-.L,ut,.�,�-���!�cccl1esac1r---t-�-1 ,� _,.,,.,/_o� Cl<IIU.Y QJTT{a (2"J'-) � ,,n,::ooc-.-�,s. Mlt)ul-.ilY{•SlM(Nl t J«!ll',, IMPROVEMENT NOTES --'---+------·--_--.n__! _ I 1���ET ____ • 1 __ I I I I f WSIIMC (ASIVOO MOTE:$ 0 !�J?����l�t,..!'°:"'��'":l 0 @ =c;� =�;1z�!��i:'S:L�= :=!M. (i) ��!i��ftf��.:'o?oo�c::l NC .ao� 0 �-�..:��a::r��J��._,_.,-'IIIOIH(C(l':.,,i,"'-""'0$($-D © :�:�..:,��?'",=:!'�� ��or��C:SIMCWo""- � © :�::�����o:_::;r,.::����<-Ul't.\.� 0 :=::.t"i:-•-:!;o-.. -:o.���:-(ll��y ""° ..co(HT .... � 0· � ��• =· � 4�,W���lltiCl-:,."f��i �,:�� .. � Cl'm&ot or om:;.,. -� (JO. �DJ (Ff����!�-:::�,=�'°"��$:�:-.:...:! II. )d)1 .. omc:1111. r,ao;,::,$ � IN>lll!,,l,UJI "° Ml(IW""'-1 00 Qfl,C,"'-<It� ( {IO 9l W,l�lll @f :;��� �': � � � ': � g.:�� :"'°°"""°' �#l;-A,,.�'IIOt<fc-1 l\ll\.llllf.SlllC[1cCfl_,,,,_5Ntl,'!Ms,,,,n/r,tl'rV'll(l!S -, Sll)f!W l)iMNS "'° -.s � "'I: cc,,,o,.,,is.. ClliiU$. •.fliS. "O.U IHI Qflli.11 � �AC$ ll(COJl:OCC _,.-., l•, 100I .. Ol"l'Oirt .COJll)S ..s >IStliltJWOI" � :IOC� Q" cmt•••· •� (IO K wr.::t.AMW). PSQPOSCD fASiNOO HQID 0 =:lt��-%"'=[11flt::t'ICI' ',(M(y ..... IICQ'SS w;, rlll' © --00..us,,( lNlOIOfl ..U..JM'.D , 0'I 1111111$ #IH'.l .-:'I (lllM LEGAL DESCRIP'TlON OWNERSHIP CEATIACATE at lS'•'l Olt Nl:."11" ff (MO) ,t:jj(-"'!'._� «�t Cit lli!rDIIICCJOl»IO(Ol••fltl'Oll1 a:u ICI SAiD tl.lO!I DI! '1'11Clf.SI • K Cd. 11'.�0 1$. W.�IC • ,.,,...�1.tU:..•C.OU-OIMOlllTil-lfl«w�.UJO �;:;;;�� M � .. .-��O l•� •JJIII. LOT STATISTICS ,w;1;Jll'>JMIC"IH:/�IT...::Mo.D o::,,;oo,,...s/"1 ..... U!,11'$ SIEETNlEX *ll l(Wl,t.l"(IR,l,Cl..,V,/11«,/�1[1,/-T'f""''lil�/�IAl!!.-S:.W.W-/<IC,,.(II� IKfl? �•�1UTIII\M< -·M$l.1,,(.. •�-IJl"U�co,.,,., /IDlwS-'$."liUll�O.._ """"'� Jfr..&,.'Ol-� ... ou.-a.t:ilOI ;M)or, l-"D ��S5.IOl•IW90fla.•. GENERAL NOTES �ctli':0:(1:() J -,IHltJU!I -ltUSI ., ... .,,lll�l'I.WOllS 11(1,ot(tWl�u'j(I, �!11-,..)1)--W'!"Klill: � ISIS:IIU'I OSI tUlJ'O.Oll'J,,\-.UI l(J'l-,Oa<-bll.('V/111!) ._ Q:lt:MlllNl\lll ..:i,C{NSl..,."W._,,UI s fASIM: ZO..C· Sl'(tlflC "'-"" tlP1) o. ,_,,n l(MIC: war;,,_ .. t-,,J I l.tC-'D"Cl�-�OiYSO.K"'tlU-•t!SCoiw->""1"" IL1'httw::oi.�l,.O(�"U-IV(tl)� • fio\$�Olu.ll�lY'i0,PMiNIICOU"�C.O.SCC.W••u I. 1(\.t'l'H(N'.9"a,,,c(•1•""1COIS'ISI'(""-" ICl(.talli�,-.i.ll"l!O'«olll'ill'l:C-'1 =:'!.:'�lllCI.MQ•J(il',..9"...,lil<"'211UaJIIOIU>tT"-onr;1 11 : :-:.:�::O�"::uu,tlll,� \DIIO"-IOI � 11! fOIIH • UU ll lltS.OIIOL('ldl«.<n■r1C1r:D11W"Y .... r;i,,V...r011J,-('.ft(;-.CDf'lt.ll,/Ol/10Dl "-SC'oQf.\C:tllH· S"..o./101,.00..CCW(tllllt,$,of.115.,_;:,r,t1$� -.i a M -•'II M: Oh' d S.,,,\• -'$ $1-C-"'ll 51'((7'1;.•1'?'-S t(lt 1,,( ,:o,,s--,c.,_ (.I •·•Ill,. 'l[_, -•c.-:D UU f.t<ll. IU t5, :n��'�..C:::<��;:,,c:-:,;��IIG .. IP �CIIUIMI, f(llt N et.s.'1111:� go ... � '!llll('I 11Q lll(Q>IIU .,:{I fllClflU 1f :.ei�CfO'�SM-'101U-.JIIPl.f,_IW'$fl.llM$1(111•Mf !J oL,Jl1:IWIU 'S .._, � (�� #OJ-"!'S-.,_. 1lr[ 111-IJTd • ,0.:,()tlhtll'S�-.-..C:..:LM;'f,lll-·O,IIYfi$10'1,C..,, ,,,_, "'° Q#;Lt!HP,-':(11/1/Q. 5l,lJlWl'I' -S MU f/.ll ot:TJUO lllll,_ •• �MllCilldN�n:,llo01"""$'1'$&•--N!MtSdWSl'fW)LI:' -•,....•1t11�M4;-1..C,ITl10o(��-\OII It �fJf-""'1JC'_, •• Cl),,,.ll,)ff..--r.T•S--�l.-ctlG$Nrr;r,T �,n.-; WSOF�- - ""'fi Ila',,_«•-$ 'i. l.lf51"'--.. u ... ali"...:'t(O,lllt�Hllll■f;ll.0:0t1Pl,.;,[ �. :C��il(I� « 10 - "-Q.l:ID<T1no,,c �os ..... u '1. IO'II ..O•ll.tl'UOl��O. ,n_,,,..,.Cr.0:�0,,lWf-Ol#i tl�-19\! lO'SfOII ....... r-, oo.t.RJC-,_,Cllaolllll P'IH'QI.$ :::r: ,';'f;f g� = ..,_,,-..., U:� IQ:,; NO. 1!1:0,1111(0 f� n P1110111011t:•�-••,M)-�'tl(�., .... -• 'Wlt;l(:M:"rw,,,.n;t,i•JO-W.:r.:i,-,r.-11.ca»111� 1i.1,IVli _.J,Q.l,ll;ll11o(!llll.CBOS-O,.Hll'f'ICIJ,'l.lll,t lllo('IIU#{'Vll'lj 1'11Sl'Uio-.,_Nllltl''-'Sllltt�(WIH'!llCID6),f•irU#ill0C..ll:)o$k.r.( =�:=1�fM l,C._,,.t lf<e..,.GUS l'4"1.l-OIIJL.IIS•t■� n.soo:,o,cis..:1�u.tU•�U<if'(O :IOI IIUSQ.«.('!.0Jllllll(lt,fb6.W)PL)(S-Cll:O!Si>IG$-,St.;1M:tUl•..::, -- 0ISle. 11H ACl l(�oln a. SIUl llll! ft:"°""' •Mo II,(� 11011•�•""' \ ....:;, 1D - t'I W:O,-,OIOI.H0-1U(l!��U(l.lot} •U:"IO l!t.CU.11"" H lll.lo(l',"-OI l«o1'1(;$111UTM:(($)-l((tf\Jtl•l,i-Ml(l'O'iUJ �'1..illll'l!QIU010WOTrCfWIJ.,.,.,,rotOll:1'0'H:I\'"' 21 �i:�;;tt;::s:�1:.=�t:..�'-"�-S/XhlCO,.» 111!9"_-QjW�Sl'lt:"-"'ll';lr;lolT"IIIL)OI.N..iYOlllllll.lll l(-0011�.UliASlt:«SSW,�COW,U-/XK«:Mt-10lK �� :_ :::t �.:._ � �,-.i.m ,u,,,-... Exhibit 8 t �·�, I"",.,.., . v�!r.n� -��' 0 � a: � w rffll gi a: :r: ,z �-:/1 •· .. v i''" v&.:· .. u I I I ,.I I;:, I I I I I II oor...s:s_.., -l!Mo..l.l)fOI ..0,'10.<S5t-.f "�Cllr\� I♦ 1\101',�=/'oe.::� •' ! �:Ill�·� j $ .. 1...,s--.g-, .' I' ,., , , I ________________ J __ _ ""'��1:':11 f 1ST STREET .• 1 ,,::-,:,;u '-ll.��+::----��"--� ��-�--------- w.llll) -----a·,o•IUII I I • ,. I ------�-...,1t .. 111i;l(01IXo.lfDIOOT> NOTE __ _ "".��= r�=-�•NU , ..,..-,:.;,� � �1::1"�:;_ :�i o(��1 .. I �---�=------.-,,==-----.-�--�==-------r----,----,----,--------------.---=---l' �=--... ,... .. AS s .... --�--PRELIMINARY UTILITY PLAN ¥ / I ;::, A IM IO r:;" ·-""'""' TENTATIVE TRACT MAP NO. 19274 � N»MS mlfml 101 NORTH HARBOR BOULEVARD TTM 2 � fv<"� '1"1 •�'"•••• ��8::'•�.e. sun .. • L-CC"------' CITYOfSANTAAAA.COUNTYOfOAANGE, -g_ -� l,is..:t Pl'-11m•2021 eoomttn -11>.t:�""' STATEOFCAl.tFORNIA Exhibit 8 Prepared by: Megan A. Lam Transportation Engineer Ill TRAFFIC AND PARKING ANALYSIS FIRST HARBOR MIXED-USE PROJECT Santa Ana, California October 23, 2023 Prepared for: HARBOR & FIRST, LLC 750 N. Diamond Bar Boulevard, Suite 101 Diamond Bar, CA 91765 LLG Ref. 2.23.4737.1 Under the Supervision of: Trissa de Jesus Allen, P.E., RSP Senior Transportation Engineer LINSCOTT LAW & GREENSPAN engineers Linscott. law& Greenspan. Engineers 2 Executive Circle Suite 2.50 lrvme.CA9Z614 949.825.6175 T 9QS.825.6l73 F w1Mv.llgeng,neers.com Exhibit 9 TABLE OF CONTENTS SECTION PAGE 1.0 Introduction ................................................................................................................................. 1 I.I Scope ofWork ...................................................................................................................... l 1.2 Study Area ............................................................................................................................ 2 2.0 Project Description ..................................................................................................................... 3 2.1 Site Access ............................................................................................................................ 3 2.2 Pedestrian and Bicycle Circulation ....................................................................................... 3 3.0 Existing (2023) Conditions ......................................................................................................... 4 3. I Existing Street System .......................................................................................................... 4 3.2 Existing Traffic Volumes ...................................................................................................... 4 3.3 Existing Public Transportation ............................................................................................. 5 3.4 Existing Intersection Conditions ........................................................................................... 6 3.4.1 Intersection Capacity Utilization (ICU) Method of Analysis ..................................... 6 3.4.2 Highway Capacity Manual (HCM) Method of Analysis (Unsignalized Intersections) ....................................................................................... 6 3.4.3 Level of Service Criteria ............................................................................................. 9 3 .5 Existing Level of Service Results ......................................................................................... 9 4.0 Traffic Forecasts ....................................................................................................................... 11 4.1 Project Traffic Generation .................................................................................................. 12 4.2 Project Traffic Distribution and Assignment.. .................................................................... 12 4.3 Existing Plus Project Traffic Volumes ............................................................................... 14 4.4 Year2028 Cumulative Base ............................................................................................... 14 4.4.1 Ambient Traffic Growth ........................................................................................... 14 4.4.2 Cumulative Projects .................................................................................................. 14 4.4.3 Year 2028 Cumulative Base Traffic Volumes .......................................................... 17 4.4.4 Year 2028 Cumulative Plus Project Traffic Volumes .............................................. 17 5.0 Non-CEQA Traffic Analysis .................................................................................................... 18 5.1 LOS Standards and Thresholds ........................................................................................... 18 5 .2 Traffic Analysis Scenarios .................................................................................................. 18 5.3 Existing (2023) Plus Project Traffic Conditions ................................................................. 19 5 .4 Year 2028 Traffic Conditions ............................................................................................. 21 5.4.1 Year 2028 Cumulative Base Traffic Conditions ....................................................... 21 5.4.2 Year 2028 Cumulative Plus Project Conditions ....................................................... 21 6.0 Site Access and Internal Circulati6n Evaluation ................................................................... 23 6.1 Site Access .......................................................................................................................... 23 6.1.1 Traffic Gap Assessment ............................................................................................ 25 6.2 Internal Circulation Evaluation ........................................................................................... 28 6.3 Sight Distance Evaluation ................................................................................................... 28 LINSCOTT, LAW & GREENSPAN, engineers LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N· ·.+70(11:Z:ZH7J7. F,r,t H:i,bor ;\,l11.ed t:s�. S:111ta Ana'R,:po,rl47J7 F11-s1 lfarbor �lu;�d-Us�, Santa ,-\na Traffic Stl1dy 10-2J-2J doc Exhibit 9 TABLE OF CONTENTS (CONTINUED) SECTION PAGE 7.0 Intersection Turn Pocket Queuing Analysis ........................................................................... 30 8.0 Congestion Management Program (CMP) Compliance Assessment ................................... 34 9.0 Roadway Segment Evaluation ................................................................................................. 35 9.1 Roadway Link Capacities ................................................................................................... 35 9.2 Roadway Link Level of Service Criteria ............................................................................ 35 9.3 Roadway Segment Analysis Results ................................................................................... 37 9.3.1 Existing Plus Project Analysis .................................................................................. 37 9.3.2 Year 2028 Plus Project Analysis ............................................................................... 39 10.0 CEQA Assessment ofVMT, Active Transportation, & Public Transit ............................... 41 IO.I Vehicle Miles Traveled (VMT) Screening Analysis .......................................................... 41 10.2 Active Transportation and Public Transit Screening Analysis ........................................... 41 11.0 Parking Analysis and Parking Management Plan (PMP) ..................................................... 43 1 I. 1 City Code Parking Requirements ........................................................................................ 43 11.2 Parking Management Plan (PMP) ...................................................................................... 43 11.3 PMP Measures .................................................................................................................... 45 12.0 Summary Of Findings And Conclusions ................................................................................ 48 LINSCOTT, LAW & GREENSPAN, engineers ii LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N·;.170{1111J--17J7 -Fu;t 1--farbor Mi"ed lls.:, S;J.11t;i Ana'R�porN7J7 first H:ubor �IJ>.�d-L'�. Santa Ana Traffie Study I0-2J-2J doc Exhibit 9 APPENDIX A.Existing Traffic Count Data APPENDICES B.Intersection Level of Service Calculation WorksheetsC.Project Driveway Level of Service Calculation WorksheetsD.Queuing Calculation WorksheetsLINSCOTT, LAW & GREENSPAN, engineers iii LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit 9 LIST OF FIGURES SECTION-FIGURE# FOLLOWING PAGE 1-1 Vicinity Map ..................................................................................................................... 2 2-1 Existing Site Aerial ........................................................................................................... 3 2-2 Proposed Site Plan ............................................................................................................ 3 3-1 Existing Roadway Conditions and Intersection Controls ............................................. .4 3-2 Existing AM Peak Hour Traffic Volumes ...................................................................... 5 3-3 Existing PM Peak Hour and Daily Traffic Volumes ..................................................... 5 4-1 Project Traffic Distribution Pattem ................................................................................ 13 4-2 AM Peak Hour Project Traffic Volumes ...................................................................... 13 4-3 PM Peak Hour and Daily Project Traffic Volumes ..................................................... 13 4-4 Existing Plus Project AM Peak Hour Traffic Volumes ............................................... 14 4-5 Existing Plus Project PM Peak Hour and Daily Traffic Volumes .............................. 14 4-6 Location of Cumulative Projects .................................................................................... 15 4-7 AM Peak Hour Cumulative Projects Traffic Volumes .................................................. 17 4-8 PM Peak Hour and Daily Cumulative Projects Traffic Volumes .................................. 17 4-9 Year 2028 AM Peak Hour Cumulative Base Traffic Volumes ................................... 17 4-10 Year 2028 PM Peak Hour and Daily Cumulative Base Traffic Volumes .................. 17 4-11 Year 2028 AM Peak Hour Cumulative Plus Project Traffic Volumes ....................... 17 4-12 Year 2028 PM Peak Hour and Daily Cumulative Plus Project Traffic Volumes ...... 17 6-1 Harbor Boulevard Sight Distance Analysis .................................................................. 29 6-2 Figueroa Street Sight Distance Analysis ...................................................................... 29 6-3 Figueroa Street at I st Street SBR Sight Distance Analysis ......................................... 29 6-4 Figueroa Street at 1st Street SBL Sight Distance Analysis .......................................... 29 10-1 Santa Ana Transit Priority Areas ................................................................................. .41 10-2 VMT/SP in Santa Ana as Compared to Orange County Average ............................. .41 10-3 Santa Ana Development Areas that Cannot Be Screened .......................................... .41 LINSCOTT, LAW & GREENSPAN, engineers iv LLG Re[ 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N \47D(J122J47J7 -first Harbor �{1>.cd ll�. Santa AnalR�µo, 114737 F11s1 H:ubor ;\.IJ><�d-U�. S'-'llta .\n:1. Tralli.c Study J().2J.2J.<loc Exhibit 9 LIST OF TABLES SECTION-TABLE# PAGE 3-1 Level of Service Criteria For Signalized Intersections (ICU Methodology) ............... 7 3-2 Level of Service Criteria For Unsignalized Intersections (HCM Methodology) ......... 8 3-3 Existing Peak Hour Intersection Capacity Analysis ....................................................... 10 4-1 Project Traffic Generation Forecast. ............................................................................... 13 4-2 Location and Description of Cumulative Projects .......................................................... 15 4-3 Cumulative Projects Traffic Generation Forecast .......................................................... 16 5-1 Existing Plus Project Peak Hour Intersection Capacity Analysis .................................. 20 5-2 Year 2028 Peak Hour Intersection Capacity Analysis ................................................... 22 6-1 Project Driveway Peak Hour Intersection Capacity Analysis ....................................... 24 6-2 Right-Tum Out Vehicle Gap Analysis .......................................................................... 26 6-3 Left-Tum Out Vehicle Gap Analysis ............................................................................ 27 7-1 Existing Plus Project Queuing Analysis ........................................................................ 32 7-2 Year 2028 Cumulative Plus Project Queuing Analysis ................................................ 33 9-1 Roadway Segment Capacities and Level of Service Criteria ......................................... 36 9-2 Existing Plus Project Roadway Segment Level of Service Summary ........................... 38 9-3 Year2028 Cumulative Plus Project Roadway Segment Level of Service Summary .... 40 11-1 City Code Parking Requirements .................................................................................. .44 LINSCOTT, LAW & GREENSPAN, engineers V LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N:,-17001:234737. F,r�t H:t1bor ;..i,��d l!sc, S:mta ,\i,J'R�porN7J7 F11'."t !farMr \lv,�d-l'�. S:intJ .\n:t Traffic Stud) I0-2J-2J.doe Exhibit 9 1.0 INTRODUCTION TRAFFIC AND PARKING ANALYSIS FIRST HARBOR MIXED-USE PROJECT Santa Ana, California October 23, 2023 This Traffic and Parking Analysis was conducted by Linscott, Law & Greenspan, Engineers (LLG) to determine and evaluate the potential traffic circulation and parking needs associated with the First Harbor Mixed-Use Project, which is the development of a nine-story building with 183 multifamily residential units (including studios, I-bedroom, 2-bedroom, and 3-bedroom units) and 15,182 square feet (SF) of retail on the ground floor, as proposed by Harbor & First, LLC. Of the 183 total units proposed, 15% (28 units) would be designated as low-income housing. The residential and retail uses would wrap around a four-level parking structure, consisting of two subterranean levels, one street/ground level, and a second above-ground level, and provide a total of 333 standard parking spaces. The Project site, which is currently vacant, is located on the north side of I st Street, between Harbor Boulevard and Figueroa Street, at IO I North Harbor Boulevard in the City of Santa Ana, California. The Project site exists within a Specific Plan district regulated by the Harbor Mixed Use Transit Corridor Plan; specifically, the South Transit Node District, which is comprised of the properties surrounding the Bravo Bus Rapid Transit (BRT) stations at Harbor Boulevard and 1st Street, and at Harbor Boulevard and McFadden Avenue. The South Transit Node generally anticipates three- to six-story buildings within the District, with the flexibility to allow IO stories, and has an emphasis on mixed-use development. Based on this, the Project, as proposed with nine stories and a mix of uses, is consistent with the land use plan for the South Transit Node District the Project site is located in. 1.1 Scope of Work Based on close coordination with City staff, and staying consistent with the City of Santa Ana Traffic Impact Study Guidelines (September 20 I 9), this report presents a non-CEQA transportation assessment, including an inventory of existing characteristics and traffic volumes during the AM and PM peak commute periods at key locations within the study area, forecasts of vehicular traffic anticipated to be generated by the Pr oject, evaluation of potential non-CEQA impacts of Project generated trips on the surrounding street system under Year 2028 conditions (i.e., the anticipated completion year for the Project), and site access and internal circulation analysis. As described in the City's traffic impact study guidelines, this report also provides a CEQA assessment (Project screening) of VMT, active transportation, and public transit. In addition, the last section of this report presents the parking analysis and Parking Management Plan (PMP) prepared for the Project. LINSCOTT, LAW & GREENSPAN, engineers 1 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana :,,: ,4700\2�H7J7-Fm;! H:ubor \11>.eJ Use. S:mt� Aoa'R�po•t1,1737 First 11:!rl>or Mi,.,ed-l'se, Sanu .\n:t Traffic Stud, 10-23-lJ do<" Exhibit 9 1.2 Study Area Two (2) key study intersections and one (I) key roadway segment have been identified for evaluation. The two (2) intersections/one (I) roadway segment listed below provide regional and local access to the study area and define the extent of the boundaries for this traffic investigation. Kev Study Intersections 1.Harbor Boulevard at 5th Street (City of Santa Ana)2.Harbor Boulevard at I st Street (City of Santa Ana) Kev Roadway Segment A.Figueroa Street, between 5th Street and I st Street (City of Santa Ana) Figure 1-1 presents a Vicinity Map, which illustrates the general location of the Project and depicts the study locations and surrounding street system. The Level of Service (LOS) investigations at these key locations were used to evaluate the potential traffic circulation needs associated with area growth, cumulative projects, and the proposed Project. LINSCOTT, LAW & GREENSPAN, engineers 2 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana :>ht70{1111H7J7 -F,rs, H;ubor :\ltx.:d US<!. SantJ Ana'R,:1>01 t147J7 f115\ H.ubor :\{1�,:d-VS<:. Sa11r.1 .\na Traffic StuJy 10-23-23.<loc Exhibit 9 W 5th St a 0• % l t S! t z :i: i GIi I SOURCE: GOOGLE KEY a (j) • STUDY INTERSECTION [?J = PROJECT SITE z f i 6L1Sl lQ ;z i w =Z W llll St ll: I � w SI W1stSt fl FIGURE 1-1 VICINITY MAP FIRST HARBOR MIXED-USE PROJECT, SANTA ANA i � � 1 � � Exhibit 9 2.0 PROJECT DESCRIPTION The First Harbor Mixed-Use Project proposes to develop a nine-story building with 183 multifamily residential units (including studios, I-bedroom, 2-bedroom, and 3-bedroom units) and 15,182 SF of retail on the ground floor. Of the 183 total units proposed, 15% (28 units) would be designated as low-income housing. The residential and retail uses would wrap around a four-level parking structure, consisting of two subterranean levels, one street/ground level, and a second above-ground level, and provide a total of333 standard parking spaces. As presented previously, Figure 1-1 is the Vicinity Map, which shows the general location of the Project and surrounding street system. Figure 2-1 is an existing aerial photograph of the Project site. The Project is expected to be completed and fully occupied by Year 2028. As part of the Project-specific improvements planned at the intersection of Harbor Boulevard and I st Street (Intersection No. 2) previously approved by the City, the Project will be adding a right-tum pocket (with a total length of 213 feet, comprised of 186 feet of storage length, and 27 feet of transition length) along 1st Street on the westbound approach of the intersection. 2.1 Site Access Access to the Project will be provided via one (I) right-tum in/out only driveway on Harbor Boulevard and two (2) driveways restricted to left-turns/right-turns in, and right-turns out, on Figueroa Street. 2.2 Pedestrian and Bicycle Circulation Sidewalks are provided on both sides of the street throughout most of the City. Crosswalks, pedestrian push buttons, and pedestrian indication lights are provided at all signalized intersections adjacent to the Project site. The proposed Project plans to retain this existing pedestrian infrastructure. The proposed Project will encourage walking by integrating pedestrian connections internally, as well as to nearby activities. Pedestrian circulation would be provided via existing public sidewalks along Harbor Boulevard, I st Street, and Figueroa Street within the vicinity of the Project. The proposed Project will protect the existing sidewalk along Project frontage on these roadways. The existing sidewalk system within the Project vicinity provides direct connectivity to the existing development located along major thoroughfares. Long-term bicycle storage for the residential and retail uses will be provided in two bike rooms, totaling 96 long-term bike spaces. An additional four ( 4) bicycle spaces will be provided for short term bicycle storage purposes. According to the City of Santa Ana Bikeway Master Plan, Class IV Cycle Tracks are planned on Harbor Boulevard and I st Street along the Project's frontage. LINSCOTT, LAw&GREENSPAN, engineers 3 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit 9 SOURCE: GOOGLE KEY [Z-:.:zl = PROJECT SITE FIGURE 2-1 EXISTING SITE AERIAL FIRST HARBOR MIXED-USE PROJECT, SANTA ANA Exhibit 9 .. I• I -, .,;·., i i· ! I t � lI , -t _:II ]Gi t;I ; gi, . �, .0 w , �i .,;, I! :�. l -' i 1 r· i ... l ---+----------{-------W.FlRSTSTREl."T _________________ +---j I SOURCE: PRIMIOR FIGURE 2-2 PROPOSED SITE PLAN FIRST HARBOR MIXED-USE PROJECT, SANTA ANA Exhibit 9 3.0 EXISTING (2023) CONDITIONS 3.1 Existing Street System The principal local network of streets serving the project site are Harbor Boulevard, 1 st Street, 5th Street and Figueroa Street. The following discussion provides a brief synopsis of these key area streets. The descriptions are based on an inventory of existing roadway conditions. Harbor Boulevard is generally a six-lane, divided roadway that borders the Project site to the west, oriented in the north-south direction that provides three northbound and three southbound travel lanes separated by a raised median. Harbor Boulevard will provide one (I) right-in/right-out driveway for the proposed Project. The posted speed limit on Harbor Boulevard is 40 miles per hour (mph). On-street parking is not permitted along this roadway in the vicinity of the project. The City of Santa Ana General Plan Circulation Element classifies Harbor Boulevard as a Major Arterial. Class II Buffered Bike Lanes are provided south of 1st Street in the vicinity of the project. Traffic signals control the study intersections of Harbor Boulevard at 5th Street and ]st Street. 1st Street is generally a six-lane, divided roadway that borders the Project site to the south, oriented in the east-west direction that provides three lanes in each direction separated by a TWL T striped median. The posted speed limit on I st Street is 40 mph. On-street parking is not permitted along this roadway in the vicinity of the project. The City of Santa Ana General Plan Circulation Element classifies 1st Street as a Major Arterial. Class II Buffered Bike Lanes are provided west of Harbor Boulevard in the vicinity of the project. 5th Street is generally a four-lane divided roadway east of Harbor Boulevard and a two-lane undivided roadway west of Harbor Boulevard, oriented in the east-west direction. The posted speed limit is 35 mph east of Harbor Boulevard and 30 mph west of Harbor Boulevard. On-street parking is only permitted on the north side of this roadway east of Harbor Boulevard in the vicinity of the project. The City of Santa Ana General Plan Circulation Element classifies 5th Street as a Secondary Arterial east of Harbor Boulevard and a Commuter west of Harbor Boulevard. Figueroa Street is a two-lane undivided roadway that borders the Project site to the east, oriented in the north-south direction. The prima facie speed limit is 25 mph and parking is permitted on both sides of the roadway. Figueroa Street will provide two (2) left-tum/right-turns in and right-tum out only driveways for the proposed Project. Figure 3-1 presents an inventory of the ex1stmg roadway conditions for the arterials and intersections evaluated in this report. This figure identifies the number of travel lanes for key arterials, as well as intersection configurations and controls for the key area study intersections. 3.2 Existing Traffic Volumes Two (2) key study intersections and one (1) key roadway segment have been identified as the locations at which to evaluate existing and future traffic operating conditions. Some portion of potential project-related traffic will pass through each of these intersections, and their analysis will reveal the potential need for Project-related circulation improvements. These key locations were LINSCOTT, LAW & GREENSPAN, engineers 4 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit 9 2U 5TH l30J 60 1ST l 4-0J NO SCALE 8 PHASE SIGNAL L 4i++l.) - NP ' 40 NP _J itt�l35J t ..., G) C �gi l"'1 ;;o 0 ..... l> NN CJIC l> ..... ;;o CD 0 ;;o "U "U �� (/) -f t::. ·::. ·::. ·::. ·::) I ............. -�.............. . . . . . . . . . . . . . . :-:-:-:-:-:-:-:-:-:-:-:-:-:-] 8 PHASE �············1SIGNAL ........... ........... ........... ]..JU+� ........... Ji,-• .......... NP ............ ...., NP :!J ittti ----t �gi ..... r cS �� KEY - = APPROACH LANE ASSIGNMENTe= TRAFFIC SIGNAL, -r = STOP SIGN P = PARKING, NP = NO PARKING ST p NP 1m ST IJP ( 4-0) NP FIGURE 3-1 U = UNDIVIDED, D = DIVIDED 2 = NUMBER OF TRAVEL LANES (XX)= POSTED SPEED LIMIT (MPH) ma -PROJECT SITE EXISTING ROADWAY CONDITIONS AND INTERSECTION CONTROLS FIRST HARBOR MIXED-USE PROJECT, SANTA ANA i ,,, N N .!. ' S? ..... 0 ,,, � 0.. 9 "' • '! ' !:? ...,,,... / "' • / 0 0 " :l =� "ll -�I "' I ... ... N N / c Exhibit 9 selected for evaluation based on discussions with City of Santa Ana staff and in consideration of Orange County CMP requirements. Existing daily, AM peak hour and PM peak hour traffic volumes for the two (2) key study intersections and one (I) key roadway segment evaluated in this report were obtained from manual turning movement counts conducted by Transportation Studies, inc. in August 2023. Figures 3-2 and 3-3 illustrate the existing AM and PM peak hour traffic volumes at the two (2) key study intersections evaluated in this report, respectively. Figure 3-3 also presents the existing average daily traffic volumes for the one (I) key roadway segment in the vicinity of the proposed Project. Appendix A contains the detailed peak hour and daily traffic count sheets for the key intersections and roadway segments evaluated in this report. 3.3 Existing Public Transportation Public transit bus service is provided in the project area by the Orange County Transportation Authority (OCTA). Figure 1-1 identifies the bus stop locations nearest to the Project site. Three (3) OCT A bus routes operate within the vicinity of the Project site on Harbor Boulevard and I st Street, which consist of the following: •OCTA Route 43 (Fullerton to Costa Mesa): Route 43 is a local bus route serving the Cities of Fullerton, Anaheim, Garden Grove, Santa Ana, Fountain Valley and Costa Mesa. The major route of travel is along Harbor Boulevard in the vicinity of the project. Route 43 connects to the Fullerton Transportation Center, approximately 13.8 miles from the Project site, which also connects to OCTA Routes 26, 47, 143, and 543 as well as Metrolink/Amtrak. Route 43 operates on approximately 20-minute headways during weekdays and 15-minute headways on weekends. Nearest to the project site are bus stops on Harbor Boulevard -northbound and southbound, south of pt Street. The northbound bus stop is located approximately 210 feet from the Project site and the southbound bus stop is located approximately 460 feet from the Project site. •OCTA Route 64 (Huntington Beach to Tustin): Route 64 is a local bus route serving the Cities of Tustin, Santa Ana, Garden Grove, Westminster, Midway City and Huntington Beach. The major route of travel is along I st Street in the vicinity of the project. Route 64 operates on approximately IS-minute headways during weekdays and 20-minute headways on weekends. Nearest to the project site are bus stops on I st Street -eastbound and westbound, at its intersection with Harbor Boulevard. The eastbound bus stop is located approximately 210 feet from the Project site and the westbound bus stop is located approximately 230 feet from the Project site. •OCTA Route 543 (Fullerton Transportation Center to Santa Ana): Route 543 is a Bravo route serving the Cities of Fullerton, Anaheim, Garden Grove, Santa Ana and Costa Mesa. The major route of travel is along Harbor Boulevard in the vicinity of the project. Route 543 connects to the Fullerton Transportation Center, approximately 13 .8 miles from the Project site, which also connects to OCTA Routes 26, 43, 47, and 143 as well as Metrolink/Amtrak. Route 543 operates LINSCOTT, LAW & GREENSPAN, engineers 5 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit 9 LINSCOTT LAW & GREENSPAN engineers 5TH 1ST �O SCALE ..,. co--0>1n co--) I l 94_,I 138-76, \.._ 163 -921.-139)l.( �co ::i: )> ;:o (D 0 ;:o r. '::. '::. ·::. ·:::ir ..............I.............. ,.............. :-:-:-:-:-:-:-:-:-:-:-:-:-:-] -:-:-:-:-:-:-:-:-:-:-:-:-:-:1 :-:-:-:-:-:-:-:-:-:-:-:-:-:-] ... · ·.·;.:,,,,,·;_;,,,,·�-. •. KEY [fil:fil = PROJECT SITE ST ::!l G) C rr, ;:o 0 )> ST FIGURE 3-2 EXISTING AM PEAK HOUR TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA ::l l;l I 8 I 0 "-9 .......,I C Exhibit 9 LINSCOTT LAW & GREENSPAN engineers 5TH 1ST IO �a� Jll 55J 130-65, \,_ 269 -211, 114 �kf ,-...� :r )> ;o CD 0 ;o r-:. ·::. ·::. ·::: ·::J t ·:-:-:-:-:-:-:-:-:-:-:-:-:-:4 :-:-:-:-:-:-:-:-:-:-:-:-:-:-] -:-:-:-:-:-:-:-:-:-:-:-:-:-:➔ :-:-:-:-:-:-:-:-:-:-:-:-:-:-] ··.·:..:_.·�······.1 KEY ..,S&!L = DAILY TRAFFIC VOLUMES � = PROJECT SITE ,, G) C fTl ;o 0 )> ,� (/) -i ST ST FIGURE 3-3 EXISTING PM PEAK HOUR AND DAILY TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA .., N 0 N I I 0 ., N N .., s 9 "' • .., ,.; I !;! Exhibit 9 on approximately 25-minute headways during weekdays and is closed on the weekends. Nearest to the project site are bus stops on Harbor Boulevard - northbound and southbound, south of I st Street. The northbound bus stop is located approximately 210 feet from the Project site and the southbound bus stop is located approximately 460 feet from the Project site. 3.4 Existing Intersection Conditions Existing AM and PM peak hour operating conditions for the two (2) key study intersections were evaluated using the Intersection Capacity Utilization (ICU) methodology for signalized intersections and the methodology outlined in the Highway Capacity Manual 6 (HCM 6) for unsignalized intersections (i.e. project driveways). 3.4.1 Intersection Capacity Utilization (ICU) Method of Analysis In conformance with City of Santa Ana requirements, existing AM and PM peak hour operating conditions for the key signalized study intersections were evaluated using the Intersection Capacity Utilization (ICU) method. The ICU technique is intended for signalized intersection analysis and estimates the volume to capacity (Y/C) relationship for an intersection based on the individual V/C ratios for key conflicting traffic movements. The ICU numerical value represents the percent signal (green) time, and thus capacity, required by existing and/or future traffic. It should be noted that the ICU methodology assumes uniform traffic distribution per intersection approach lane and optimal signal timing. Per City of Santa Ana requirements, the ICU calculations use a lane capacity of 1,700 vehicles per hour (vph) for through lanes and 1,600 vph for left-tum lanes and right-tum lanes. A clearance adjustment factor of 0.05 was added to each Level of Service calculation. The ICU value translates to a Level of Service (LOS) estimate, which is a relative measure of the intersection performance. The ICU value is the sum of the critical volume to capacity ratios at an intersection; it is not intended to be indicative of the LOS of each of the individual turning movements. The six qualitative categories of Level of Service have been defined along with the corresponding ICU value range and are shown in Table 3-1. 3.4.2 Highway Capacity Manual (HCM) Method of Analysis (Unsignalized Intersections) The HCM unsignalized methodology for stop-controlled intersections was utilized for the analysis of the unsignalized intersections. This methodology estimates the average control delay for each of the subject movements and determines the level of service for each movement. For all-way stop controlled intersections, the overall average control delay measured in seconds per vehicle, and level of service is then calculated for the entire intersection. For one-way and two-way stop-controlled (minor street stop-controlled) intersections, this methodology estimates the worst side street delay, measured in seconds per vehicle and determines the level of service for that approach. The HCM control delay value translates to a Level of Service (LOS) estimate, which is a relative measure of the intersection performance. The six qualitative categories of Level of Service have been defined along with the corresponding HCM control delay value range, as shown in Table 3-2. LINSCOTT, l.Aw&GREENSPAN, engineers 6 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N.14700\2�H7J7 -First Harbllr :\fix�d lJ;�. SantJ AnJ1R�1mrt147J7 Fust Harl>or ,\h>.�d-l'se, Salltn .\n,1 Tr:iffic Study W-23-23 00.: Exhibit 9 TABLE 3-1 LEVEL OF SERVICE CRITERIA FOR SIGNALIZED INTERSECTIONS (ICU METHODOLOGY) Level of Service (LOS) B C E F LINSCOTT, LAW&GREENSPAN, engineers Intersection Capacity Utilization Value (V/C) ,;; 0.600 0.601 -0.700 0. 70 I -0.800 0.80 I -0.900 0.90 I -1.000 >1.000 7 Level of Service Description EXCELLENT. No vehicle waits longer than one red light, and no approach phase is fully used. VERY GOOD. An occasional approach phase is fully utilized; many drivers begin to feel somewhat restricted within groups of vehicles. GOOD. Occasionally drivers may have to wait through more than one red light; backups may develop behind turning vehicles. FAIR. Delays may be substantial during portions of the rush hours, but enough lower volume periods occur to permit clearing of developing lines, preventing excessive backups. POOR. Represents the most vehicles intersection approaches can accommodate; may be long lines of waiting vehicles through several signal cycles. FAILURE. Backups from nearby locations or on cross streets may restrict or prevent movement of vehicles out of the intersection approaches. Potentially very long delays with continuously increasing queue lengths. LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana K;,--1700\2234737 • Fim H.11bor :,.fi��d Use. S:mt:t Ana1R�port\�737 fil'st Harhor .\hwd-l 'se.. Santa .\n:t Troffic Study !0-23-23 doc Exhibit 9 TABLE3-2 LEVEL OF SERVICE CRITERIA FOR UNSIGNALIZED INTERSECTIONS (HCM METHODOLOGY)' Level of Service Highway Capacity Manual (HCM) (LOS) Delay Per Vehicle (seconds/vehicle) Level of Service Description A s; 10.0 Little or no delay B >10.0ands; 15.0 Short traffic delays C >15.0 ands; 25.0 Average traffic delays D >25.0 ands; 35.0 Long traffic delays E >35.0 ands; 50.0 Very long traffic delays F >50.0 Severe congestion Source: Highway Capacity Manual 7'1' Edition, Chapter 20: Two-Way Stop-Controlled Intersections. The LOS criteria apply to each lane on a given approach and to each approach on the minor street. LOS is not calculated for major-street approaches or for the intersection as a whole. LINSCOTT, LAw&GREENSPAN, engineers 8 LLG Re[ 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit 9 3.4.3 Level of Service Criteria According to the City of Santa Ana, LOS D is the minimum acceptable condition that should be maintained during the peak commute hours. However, the City of Santa Ana has defined exceptions to this criterion at specific locations within the study area. The City of Santa Ana has defined major development areas where LOS "E" is considered acceptable. Based on the above, the following summarizes the LOS required for each key study intersection: LOS "D" Requirements LOS "E" Requirements I.Harbor Boulevard at 5th Street 2.Harbor Boulevard at I st Street 3.5 Existing Level of Service Results Table 3-3 summarizes the existing peak hour service level calculations for the two (2) key study intersections based on existing traffic volumes and current street geometrics. Review of Table 3-3 indicates that all key study intersections currently operate at an acceptable level of service (LOS) during the AM and PM peak hours when compared to the LOS criteria defined in this report. Appendix B presents the ICU/LOS calculation worksheets for the two (2) key study intersections for the AM peak hour and PM peak hour. LINSCOTT, LAW & GREENSPAN, engineers 9 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit 9 TABLE3-3 EXISTING PEAK HOUR INTERSECTION CAPACITY ANALYSIS Minimum Acceptable Control Time Key Intersection Jurisdiction LOS Type Period ICU LOS Harbor Boulevard at 80 Traffic AM 0.719 I. 5th Street Santa Ana D Signal PM 0.729 C Harbor Boulevard at 80 Traffic AM 0.760 2. Santa Ana E Signal I st Street PM 0.811 D Bold ICU values indicate adverse service levels based on the Cities LOS standards. LINSCOTT, LAW & GREENSPAN, enginee/S 10 LLG Ref 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Is ,.:17W122347l7 • F1m Rubor \h>.,:d Usi.:. S:mta Ana'RcporN7J7 f1r<1 Harl-or \lv,�-d-Use. Santa .\na Traffic Stud� 10-23-23 doc Exhibit 9 4.0 TRAFFIC FORECASTS In order to estimate the traffic characteristics of the proposed Project, a multi-step process has been utilized. The first step is trip generation, which estimates the total arriving and departing traffic on a peak hour and daily basis. The traffic generation potential is forecast by applying the appropriate vehicle trip generation equations or rates to the Project development tabulation. The second step of the forecasting process is trip distribution, which identifies the origins and destinations of inbound and outbound Project traffic. These origins and destinations are typically based on demographics and existing/anticipated travel patterns in the study area. The third step is traffic assignment, which involves the allocation of Project traffic to study area streets and intersections. Traffic assignment is typically based on minimization of travel time, which may or may not involve the shortest route, depending on prevailing operating conditions and travel speeds. Traffic distribution patterns are indicated by general percentage orientation, while traffic assignment allocates specific volume forecasts to individual roadway links and intersection turning movements throughout the study area. With the forecasting process complete and Project traffic assigntiients developed, the effect of the proposed Project's added traffic is isolated by comparing operational (LOS) conditions at selected key intersections using expected future traffic volumes with and without forecast Project traffic. The need for site-specific and/or cumulative local area traffic improvements can then be evaluated. LINSCOTT, LAw&GREENSPAN, engineers 11 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit 9 4.1 Project Traffic Generation Traffic generation is expressed in vehicle trip ends, defined as one-way vehicular movements, either entering or exiting the generating land use. Generation equations and/or rates used in the traffic forecasting procedure are found in the 11th Edition of Trip Generation, published by the Institute of Transportation Engineers (]TE) [Washington D.C., 2021]. The upper portion of Table 4-1 summarizes the trip generation rates used in forecasting the vehicular trips generated by the proposed Project. As shown in Table 4-1, !TE Land Use 221: Multifamily Housing Mid Rise and !TE Land Use 822: Strip Retail Plaza Less than 40K trip rates were used to forecast the trip generation potential of the proposed Project. The lower portion of Table 4-1 presents the project's forecast peak hour and daily traffic volumes, inclusive of applicable pass-by trip reductions. As shown on the bottom of Table 4-1, the proposed Project is forecast to generate approximately 1,575 daily trips, with I 00 trips (36 inbound, 64 outbound) produced in the AM peak hour and 131 trips (73 inbound, 58 outbound) produced in the PM peak hour on a "typical" weekday. Please note that trip generation for the proposed Project includes adjustments for pass-by as recommended by !TE. The pass-by reduction factors are based on a review of available information published in the 11th Edition of Trip Generation, published by the Institute of Transportation Engineers (!TE), [Washington, D.C., 2021]. 4.2 Project Traffic Distribution and Assignment Figure 4-1 presents the traffic distribution pattern for the proposed Project. Project traffic volumes both entering and exiting the project site have been distributed and assigned to the adjacent street system based on the following considerations: ■ location of site access points in relation to the surrounding street system, ■the site's proximity to major traffic carriers and regional access routes, ■ physical characteristics of the circulation system such as lane channelization and presence oftraffic signals that affect travel patterns, ■presence of traffic congestion in the surrounding vicinity, and•ingress/egress availability at the project site, as well as allowance of "U-turn" movements at5th Street and 1st Street. The anticipated AM and PM peak hour project traffic volumes associated with the proposed Project are presented in Figures 4-2 and 4-3, respectively. Figure 4-3 also presents the daily Project traffic volumes. The traffic volume assignments presented in Figures 4-2 and 4-3 reflect the traffic distribution characteristics shown in Figure 4-1 and the traffic generation forecast presented in Table 4-1. LINSCOTT, LAW & GREENSPAN, engineers 12 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana � -'700\:�34737 -f,rst H�rbor \1,,..,d l 'se. S:uttJ And'R�pon'47J7 Fir$! Harl"'r \h.>..:d-l'.�, S.111ta ;\n;1 Traffic Study l0-2J-2J.doc Exhibit 9 TABLE4-1 PROJECT TRAFFIC GENERATION FORECAST' !TE Land Use Code I Daily AM Peak Hour PM Peak Hour Project Description 2-Way Enter Exit Total Enter Exit Total Generation Factors: •221: Multifamily Housing Mid Rise (TE/DU) •822: Strip Retail Plaza Less than 40K (TEffSF) Proupsed Pro[ect Generation Forecast: •Residential (183 DU) •Retail (15,182 SF) Pass-by (Daily: IO%, AM: I 0% PM: 40%)3 Retail Subtotal Total Project Trip Generation Notes: •TE/DU = Trip ends per dwelling unit•TEffSF = Trip ends per thousand square feet 4.54 23% 54.45 60% 831 16 827 22 -83 :6 744 20 1,575 36 77% 0.37 61% 39% 40% 2.36 50% 50% 52 68 43 28 14 36 50 50 :6 .:1 -20 -20 12 32 30 30 64 100 73 58 2 3 Source: Trip Generation, 11th Edition, Institute ofTransportation Engineers, (ITE) [Washington, D.C. (2021)}. Source: The /TE Trip Generation Manual does not contain pass-by infonnatioti for the ITE LU 822: Strip Retail Plaza Less than 40K. Therefore, the Daily, AM peak hour, and PM peak hour pass-by rates were conservatively assumed to be 10% (estimated) for Daily, 10% (estimated) for AM peak hour, and 40% for PM peak hour (consistent with ITE LU 821 pass-by rates). LINSCOTT, LAW & GREENSPAN, engineelS 13 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana 0.39 6.59 71 JOO -40 60 131 Exhibit 9 � 5TH <)g◊. 1ST LINSCOTT LAW & GREENSPAN engineers �NO SCALE � 0 I') � 5ll:9 8 95,: flit j���� 01()01{) � n I )> :;o OJ 0 :;o ............... :!J G) C fT1 :;o 0 )> ::::::.fitN :f� [;-.............. I' ........ ·:::::::::::::.'- ST <)v ST KEY @ ,. STUDY INTERSECTION q-= INBOUND PERCENTAGE FIGURE 4-1 - = OUTBOUND PERCENTAGE PROJECT TRAFFIC rz:a = PROJECT s1TE n1sTRIBUTION PATTERN FIRST HARBOR MIXED-USE PROJECT, SANTA ANA 9 Exhibit 9 LINSCOTT LAW & GREENSPAN engineerc. 5TH 1ST �O SCALE o:=o JI l... o--J o-2, \._ 0 -or2)�.( I )> ;;o CD 0 ;;o CD r KEY (XX)= PASS-BY TRIPS�ii = PROJECT SITE ST :::!:l 0 )> \ \ FIGURE 4-2 AM PEAK HOUR PROJECT TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA 9 Exhibit 9 LINSCOTT LAW & GREENSPAN e11gineers 5TI-i 1ST �OSCALE N \._ 0ONO -oJ I I... ,4 ST o-' ill! o-4, C fT1 ;;o 0 )> I > ;;o ID 1� 0 ;;o ,,-r--,,,,,-�, ,, / ' / ' I � \ Vl I 00 \ I I \._ 29(9)J � 1 J I \ \ I ( I \ 9(aellt Io,:::-/\I 'co' I \ � ✓-...... / ' I/')< / - - _,, -_ _,, / ' -_(-.-. .'":"T.'":"T.'":"T.� [\--'" 7WY 1.'.'.'0WYT.' t-·.·.·.·.·.·.·.·.·:.·.·.·.·.� :·:·:·:·:·:·:·:·:·:·:·:·:·:·] ::::::-ow :s·� 1)--................. f' ....... ·:::::::::::::." ST ID § KEY Aa = DAILY TRAFFIC VOLUMES (XX)= PASS-BY TRIPS '\ \ >---r--' / §: ' I oo, \ , J I \ \ 20(3�1,l. I \ � I ' - / --_,, FIGURE 4-3 �:� = PROJECT SITE PM PEAK HOUR AND DAILY PROJECT TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA I .., Exhibit 9 4.3 Existing Plus Project Traffic Volumes The Existing Plus Project traffic conditions have been generated based upon existing conditions and the estimated project traffic. These forecast traffic conditions have been prepared to assess the potential effects of the Project upon the circulation system as it currently exists per the requirements of the City. This traffic volume scenario and the related intersection capacity analyses will identify the roadway improvements necessary to offset the Project, if any. Figures 4-4 and 4-5 present projected AM and PM peak hour traffic volumes at the two (2) key study intersections and three (3) Project driveways with the addition of the trips generated by the proposed Project to existing traffic volumes, respectively. Figure 4-5 also presents the Existing Plus Project daily traffic volumes. 4.4 Year 2028 Cumulative Base 4.4.1 Ambient Traffic Growth Horizon year, background traffic growth estimates have been calculated using an ambient traffic growth factor. The ambient traffic growth factor is intended to include unknown and future related projects in the study area, as well as account for regular growth in traffic volumes due to the development of projects outside the study area. The future growth in traffic volumes has been calculated at one percent (1.0%) per year. Applied to the Year 2023 existing traffic volumes, this factor results in a 5.0% growth in existing volumes to the near-term horizon year 2028. 4.4.2 Cumulative Projects In order to make a realistic estimate of future on-street conditions prior to implementation of the proposed Project, the status of other known development projects (related projects) within a two mile radius of the proposed project has been researched at the City of Santa Ana, City of Garden Grove, City of Fountain Valley and City of Westminster. With this information, the potential circulation effects of the proposed Project can be evaluated within the context of the cumulative impact of all ongoing development. Based on our research during the scoping process, there are nine (9) related projects in the City of Santa Ana and one (1) related project in the City of Garden Grove that are being processed for approval or to be constructed and fully operational within a two-mile radius of the proposed project site. These ten (10) related projects have been included as part of the cumulative background setting. Table 4-2 provides a brief description for each of the ten (10) related projects. Figure 4-6 graphically illustrates the location of the ten (10) related projects. These related projects are expected to generate vehicular traffic, which may affect the operating conditions of the key study intersections. Table 4-3 summarizes the trip generation potential for all ten (10) related projects on a daily and peak hour basis for a typical weekday. As shown, the related projects are expected to generate 4,705 daily trips, with 245 trips (103 inbound, 142 outbound) anticipated during the AM peak hour and 287 trips (162 inbound, 125 outbound) produced during the PM peak hour. LINSCOTT, LAW & GREENSPAN, engineers 14 LLG Ref 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit 9 LINSCOTT LAW & GREENSPAN engineers 5TH 1ST I I \ ,,.....-;r--, / � '\. N I \.._ 33 I.( "'--o,LO«>-- ) I l... 94---' 138- 78, \ I I \ �N I'-:---< ...._ \.._ 163 -92,-141 �l! .. <O - I ;o CD 0 '---l �_.,..,._.,..,._..,..,.:-=lrl [:I?"!!.!-:-:-��?-� --......_ / /N / ......... \.._ ,so< o,-..n I --N -533\I ) I l ,-216 I \ 149---' )!! / 835-\ 197, �:8�/ '-/ ...._ - _,, .............. :-:-:-:-:-:-:-:-:-:-:-:-:-:-] . ·::.·.·.·.·.·.·.·.·:.·.•j ::::::.ow{ :s·� .............. 1 . . .. . . . . .. . . . . .............. .. ........ / / / CD r s KEY fiil = PROJECT SITE ;o 0 l> -t �/ >' � ' ST ,,.....-,--......_/ 0� I ) I I \ o---' 1� \ /'-/ ...._ '\. \ \ '\. \ I )J I N I/ L.. _,, ST )..- - r-- ......_ / " 0� \ I I ) I I \ o---' 11 I 22, .og \ I ' / ...._ L.. _,, FIGURE 4-4 EXISTING PLUS PROJECT AM PEAK HOUR TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA "' N � I N I � ;. ,;; ;; I :!. ...."' .... •,.;; 0 e 0 � ii : � 'll i � 0 � I ....• ....• e Exhibit 9 LINSCOTT LAW & GREENSPAN engineers 5TH 1ST I I \ ,,,,.-r-' / � '\. N I \.._ 3J t r Olt'l ..,._"' <ON- ) I l gg-J 146-82, \ I I 00> \ <ON I N - < '--- _,,. '-....( / / / �-.--, / /:2�� \.._ 191 I --N -668\I ) j l r 227 \ \ 158_./ ),1.( I \ 879-���/20� / '--.... _,,. \.._ 171 -97, 110 ��f N :c )> ;:o CD 0 ;:o �_..,..,._..,..,._.,...._� [:��-!-:-:-:��-:�-� .............. :-:-:-:-:-:-:-:-:-:-:-:-:-:-] ···········:4·· .............. -:-:-:-:-:-:��:-}::: .. . . . . . . .. . ... • •:• ·:· ·:··:.'I CD r s KEY :!! C) C fTI ;:o 0 )> t� Vl -t '\,--/ ., � ' ST ,,,,.-/ 0� I ) l I o-' \ 1� \ /'-/ - '- '\ \ .--, '\. \ \ 'I t I ,..,00 N I / .__,,- ST ).--,.._' / o::S '\. I \ I ) I \ o-' 1 t I \ 22, "',';i \ I '-/ -- _,,. �OSCALE � = DAILY TRAmc VOLUMES [fil:::/J -PROJECT SITE FIGURE 4-5 EXISTING PLUS PROJECT PM PEAK HOUR AND DAILY TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA i 2 a. j ..., N 0 N I ..., N I :;! ;;; : ,;; 9 "' I :!: ......,...•�• g 0 � a:i2 E � _g i?"' I ...•..., • ,('. C Exhibit 9 TABLE4·2 LOCATION AND DESCRIPTION OF CUMULATIVE PROJECTS' No. Cumulative Project City of Santa Ana I.Habitat for Humanity 2.Westview Housing 3.Haphan Residential Development 4.Bewley Street Townhomes 5. 5th and Harbor Mixed-UseDevelopment 6. Bella Terra Residential Community and Temple 7. Mountain View 8-Unit Condominium Development 8.Coptic Orthodox Church Euclid-Hazard ?-Eleven Service9. Station City o(Garden Grove 10.Harbor Place Pad Building Notes: SF= Square-feet DU = Dwelling units VFP = Vehicle Fueling Positions Location/Address 1921 West Washington Avenue 2534 West Westminster Avenue 3025 West Edinger Avenue 1122 North Bewley Street 419-421 North Harbor Boulevard 4006,4010, aud 4018 West Hazard Avenue 301 and 305 North Mountain View Street 4405 West Edinger Avenue 813 North Euclid Street 13200-13220 Harbor Boulevard 4 Source: City of Santa Ana and City of Garden Grove Planning Departments. LINSCOTT, LAw&GREENSPAN, engineers 15 Description 6 DU Affordable Housing 85 DU Multi-family Residential 18 DU Multi-family Residential 10 DU Condominium 94 DU Multi-family Residential 9,500 SF Retail 13 DU Single-family Residential 3,500 SF Temple 8 DU Condominium 110 Seat Expansion for Church 8VFP 3,045 SF Convenience Store 2,800 SF Fast Food Restaurant with Drive-thru 1,200 SF Restaurant LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit 9 KEY 1. HABITAT FOR HUMANITY 2. WESTVIEW HOUSING 3. HAPHAN RESIDENTIAL DEVELOPMENT 4. BEWLEY STREET TOWNHOMES 5. 5TH AND HARBOR MIXED-USE DEVELOPMENT 6. BELLA TERRA RESIDENTIAL COMMUNITY AND TEMPLE 7. MOUNTAIN VIEW 8-UNIT CONDOMINIUMS DEVELOPMENT 8. COPTIC ORTHODOX CHURCH 9. EUCLID-HARARD 7-ELEVEN SERVICE STATION 10. HARBOR PLACE PAD BUILDING Garden Grove' f J i I KEY (j) CUMULATIVE PROJECT LOCATION E\] -PROJECT SITE FIGURE 4-6 LOCATION OF CUMULATIVE PROJECTS FIRST HARBOR MIXED-USE PROJECT, SANTA ANA Exhibit 9 TABLE4-3 CUMULATIVE PROJECTS TRAFFIC GENERATION FORECAST' Daily AM Peak Hour PM Peak Hour Cumulative Project Description 2-Way In Out Total In Out Total l.Habitat for Humanity 40 0 2 2 2 I 2.Westview Housing 573 8 26 34 27 16 3.Haphan Residential Development 121 2 5 7 6 3 4.Bewley Street Townhomes 67 I 3 4 3 2 5.5th and Harbor Mixed-Use Development 1,099 21 37 58 49 37 6. Bella Terra Residential Community and Temple 115 2 4 6 5 4 7.Mountain View 8-Unit CondominiumDevelopment 54 I 2 3 3 I 8.Coptic Orthodox Church 99 5 3 8 5 6 9.Euclid-Hazard ?-Eleven Service Station 1,426 , 25 25 50 33 32 10.Harbor Place Pad Building 1,111 38 35 73 29 23 Cumulative Projects 4,705 103 Total Trip Generation Potential 142 245 162 125 s Unless otherwise noted, Source: Trip Generation, 1 l1h Edition, Institute of Transportation Engineers (ITE), Washington, D.C. (2021). LINSCOTT, LAW & GREENSPAN, engineers 16 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana 3 43 9 5 86 9 4 11 65 52 287 Exhibit 9 The AM and PM peak hour traffic volumes associated with the ten (I 0) related projects in the Year 2028 are presented in Figures 4-7 and 4-8, respectively. Figure 4-8 also presents the daily related project traffic volumes. 4.4.3 Year 2028 Cumulative Base Traffic Volumes Figures 4-9 and 4-10 present the AM and PM peak hour cumulative base traffic volumes ( existing traffic + ambient growth + cumulative projects) at the two (2) key study intersections for the Year 2028, respectively. 4.4.4 Year 2028 Cumulative Plus Project Traffic Volumes Figures 4-11 and 4-12 illustrate the Year 2028 forecast AM and PM peak hour traffic volumes, with the inclusion of the trips generated by the proposed Project, respectively. LINSCOTT, LAW&GREENSPAN, engineers 17 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N ,-J700\12H7J7 -Ftr�t H:ubor Mi�"J L-se. S:mta AJ1a'Rc1)011·-HJ7 fm,t Harbor �fixed-Use. Santa .\na Traffic Study lfJ-23-23.doc Exhibit 9 LINSCOTT LAW & GREENSPAN engineer, 5TH 1ST �O SCALE OO>CO Jll.... o-' 1-°' \__ 0 -or 22:)J[ I ► ;o (D 0 ;o r.':. ·::. ·::. ·::: • ::'1 t ............. -�.............. . . . . . . . .. . . .. . � .............. 1. . . . . . . .. . . . . . .............. -:-:-:-:-:-:-:-:-:-:-:-:-:-:1 :-:-:-:-:-:-:-:-:-:-:-:-:-:-] KEY fE:)� = PROJECT SITE 0 ► (/) --i ST ST FIGURE 4-7 AM PEAK HOUR CUMULATIVE PROJECT TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA I .., N I 9 "' • I � Exhibit 9 LINSCOTT LAW & GREENSPAN engi11een 5TH 1ST �OSCALE CCX>� \.._ 0 ) � l,. -or 22o---' �.LC 2- � :r: CD 0 ;:o KEY ...BJ2!L • OAJLY TRAFFIC VOLUMES �� = PROJECT SITE :!l fTI ;:o 0 )> lo (/) -i ST ST FIGURE 4-8 PM PEAK HOUR AND DAILY CUMULATIVE PROJECT TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA N I I 0 9 Exhibit 9 LINSCOTT LAW & GREENSPAN engineen 5TH 1ST �O SCALE �g;in(ON� Jil 99---' 146-BO-\ \._ 171 -97 r 1ss �if r )> w 0 ;:o r.·::.·::.·::.·:::i-:-:-:-:-:-:-:-:-:-:-:-:-:-:� :-:-:-:-:-:-:-:-:-:-:-:-:-:-] -:-:-:-:-:-:-:-:-:-:-:-:-:-:1 :-:-:-:-:-:-:-:-:-:-:-:-:-:-] w s KEY filll = PROJECT SITE )> (/) -t ST ST FIGURE 4-9 YEAR 2028 AM PEAK HOUR CUMULATIVE BASE TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA I .... N I 0 ;. 00 9 Exhibit 9 LINSCOTT LAW & GREENSPAN e11gi11eers 51H 1ST �OSCALE :3in <D•r--co�� J I \.. 58-' 139-68, \._ 282 -222r 142)Ir a,�� I )> ;u CD 0 ;u f::::::::::::::J [·:-:-:-:-:-:-:-:-:-:-:-:-:-:�:-:-:-:-:-:-:-:-:-:-:-:-:-:-]-:-:-:-:-:-:-:-:-:-:-:-:-:-:1:-:-:-:-:-:-:-:-:-:-:-:-:-:-] • ·:,:,.:_: ••••••• ·.1 CD KEY � = DAILY TRAFFIC VOLUMES Elful = PROJECT SITE 0 )> 1, (/) --l ST ST FIGURE 4-10 YEAR 2028 PM PEAK HOUR AND DAILY CUMULATIVE BASE TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA I ,,,NI Exhibit 9 LINSCOTT LAW & GREENSPAN engineers 5TH 1ST �O SCALE ,., ..,.oin \.._ 171 r.oN� -97Jll r 110 ST gg-J �.i.( 146-in -"' 82, N "Tl G) C ITI :;:o 0 )> ::i:: )> :;:o CD 0 _:;:o ............... ::::::.ow{ :f.,'..:j 1)---.. •:•:<-:·:•:·:·:·:·:·:·:·:·:" ', ... """"""'-" ST KEY �� = PROJECT SITE FIGURE 4-11 YEAR 2028 AM PEAK HOUR CUMULATIVE PLUS PROJECT TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA ..,� I ..,N I 0 Exhibit 9 LINSCOTT LAW & GREENSPAN engineers 5TH 1ST �OSCALE IO '---282:g�� ---222Jll r 146 58_) �1!139-n, -�� I > ;:o Ill 0 ;:o Ill � KEY ...!!a1Q!L = DAILY TRAFFIC VOLUMES �❖:m = PROJECT SITE ST ::!l "' C fTl ;o 0 > ti \ \ FIGURE 4-12 YEAR 2028 PM PEAK HOUR AND DAILY CUMULATIVE PLUS PROJECT TRAFFIC VOLUMES FIRST HARBOR MIXED-USE PROJECT, SANTA ANA I .., N I 0 ,._ .., ,._ I .. :, Exhibit 9 5.0 NON-CEQA TRAFFIC ANALYSIS The relative effect of the proposed Project during the AM peak hour and PM peak hour was evaluated based on analysis of future operating conditions at the two (2) key study intersections, without, then with, the proposed Project. The previously discussed capacity analysis procedures were utilized to investigate the future volume-to-capacity relationships and LOS characteristics at each study intersection. The potential effect of the Project at each key intersection was then evaluated using LOS standards and thresholds summarized below. 5.1 LOS Standards and Thresholds 5.1.1 City of Santa Ana Based on the City of Santa Ana, the need for potential improvements will be assessed based on the following criteria: ■ Project traffic would cause an intersection currently operating at an acceptable peak hour Levelof Service (LOS) to operate at an unacceptable peak hour LOS. The City of Santa Ana considersLOS D to be the minimum acceptable LOS for all intersections, or •The project increases traffic demand by 1% of capacity (ICU increase� 0.01) if the intersectionalready operates at an unacceptable LOS. ■At unsignalized intersections, the project causes an intersection at LOS D or better to degrade toLOS EorF. 5.2 Traffic Analysis Scenarios The following scenarios are those for which volume/capacity calculations have been performed at the five (5) key intersections for existing plus project and near-term (Year 2028) traffic conditions: A.Existing Traffic Conditions; B.Existing Plus Project Traffic Conditions; C.Scenario (B) with Improvements, if necessary; D.Near-Term (Year 2028) Cumulative Traffic Conditions, E.Near-Term (Year 2028) Cumulative plus Project Traffic Conditions; F.Scenario (E) with Project-Related Mitigation, if necessary. LINSCOTT, LAW & GREENSPAN, engineers 18 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N ,-1700·213�737 -F,rsl Ha,bor �h��d t.::�e. S:tnt:t Ana'Rt1lort'47J7 Fust HaJ l'Or M,��d-l'�. Sa.iu:i .\n:t Traffic Stud) 10-2J-23.doc Exhibit 9 5.3 Existing (2023) Plus Project Traffic Conditions Table 5-1 summarizes the peak hour Level of Service results at the two (2) key study intersections for existing plus project traffic conditions. The first column (I) of ICU/LOS values in Table 8-1 presents a summary of existing AM and PM peak hour traffic conditions (which were also presented in Table 3-3). The second column (2) lists existing plus project traffic conditions. The third column (3)shows the increase in ICU value due to the added peak hour Project trips and indicates whether the traffic associated with the Project will exceed the LOS thresholds defined in this report. The project-specific intersection improvement described below has been presumed as part of the evaluation of Existing Plus Project traffic conditions: ■No. 2 -Harbor Boulevard at I st Street: Widen the westbound approach of the intersection to provide an exclusive westbound right-tum lane on !st Street with 190-feet of storage. Review of Column 3 of Table 5-1 indicates that the two (2) key study intersections are forecast to operate at LOS D or better during the weekday AM and PM peak hours with the addition of Project traffic to Existing traffic conditions. Review of Columns 2 and 3 of Table 5-1 indicates that the traffic associated with the proposed Project will not require improvements at either of the two (2) key study intersections, when compared to the LOS standards and thresholds specified in this report. Appendix B presents the existing plus project ICU/LOS calculations for the two (2) key study intersections. LINSCOTT, LAW & GREENSPAN, engineers 19 LLG Ref 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit 9 TABLE 5-1 ExiSTING PLUS PROJECT PEAK HOUR INTERSECTION CAPACITY ANALYSIS e ;:a (I) (2) • s"'Existing Existing Plus Project .§ c.C .s tt ...l Traffic Conditions Traffic Conditions :,q Time Key Intenection Period ICUillCM LOS ICUillCM LOS Harbor Boulevard at AM 0.719 C 0.730 C I. 5th Street D PM 0.729 C 0.733 C Harbor Boulevard at AM 0.760 C 0.765 C 2. 1st Street6 E PM 0.811 D 0.789 C � Bold ICU values indicate adverse service levels based on the Cities LOS standards. 6 A 190-foot westbOW1d ri5ht-turn pocket at the intersection ofHatborBoulevard and I"' Street will be constructed as part of the proposed Proiect. LINSCOTT, LAW & GREENSPAN, engineers 20 (J) Exceeds LOS Thresholds Increase Y-o 0.011 No 0.004 No 0.005 No -0.022 No LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Pr(!ject, Santa Ana Exhibit 9 5.4 Year 2028 Traffic Conditions Table 5-2 summarizes the peak hour Level of Service results at the two (2) key study intersections for the Year 2028 horizon year. The first column (I) of ICU/LOS values in Table 5-2 presents a summary of existing AM and PM peak hour traffic conditions. The second column (2) lists projected cumulative traffic conditions (existing plus ambient plus related projects traffic) based on existing intersection geometry, but without any traffic generated from the proposed Project. The third column (3) presents forecast Year 2028 near-term traffic conditions with the addition of Project traffic. The fourth column (4) shows the increase in ICU value due to the added peak hour Project trips and indicates whether the traffic associated with the Project will exceed the LOS thresholds defined in this report. The project-specific intersection improvement described below has been presumed as part of the evaluation of Year 2028 Cumulative Plus Project traffic conditions: •No. 2 -Harbor Boulevard at 1'1 Street: Widen the westbound approach of the intersection to provide an exclusive westbound right-tum lane on 1st Street with 190-feet of storage. 5.4.1 Year 2028 Cumulative Base Traffic Conditions Review of Column 2 of Table 5-2 indicates that the two (2) key study intersections are forecast to continue to operate at acceptable levels of service (LOS D or better) during the AM and PM peak hours for Year 2028 Cumulative Base traffic conditions. 5.4.2 Year 2028 Cumulative Plus Project Conditions Review of Column 3 of Table 5-2 indicates that the two (2) key study intersections are forecast to continue to operate at acceptable levels of service (LOS D or better) during the AM and PM peak hours with the addition of Project traffic to Year 2028 Cumulative traffic conditions. Review of Columns 3 and 4 of Table 5-2 indicates that the traffic associated with the proposed Project will not require improvements at either of the two (2) key study intersections, when compared to the LOS standards and thresholds specified in this report. Appendix B also presents the near-term ICU/LOS calculations for the two (2) key study intersections. LINSCOTT, LAW & GREENSPAN, engineers 21 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N' ,4700·.21J-1737. F1rs1 Harbor \!,xed l'�e. S:inta ,\na'R�l'O' 1 47J7 Fir�\ H:u l>or \h\�d-L:'<1!, S.uua Ana Tr:iffic Study 10-2J-1J <l<1c Exhibit 9 TABLE5•2 YEAR 2028 PEAK HOUR INTERSECTION CAPACITY ANALYSIS 8 .. = a r,i (I) (2) .§ �s Existing Year 2028 .5 � Traffic Conditions Traffic Conditions :q Time Key Intersection Period ICU/HCM LOS ICUillCM LOS Harbor Boulevard at AM 0.719 C 0.770 C I. 5th Street D PM 0.729 C 0.781 C Harbor Boulevard at AM 0,760 C 0.801 D 2. 1'1 Street7 E PM 0.811 D 0.864 D � Bold ICU values indicate adverse service levels based on the Cities LOS standards 7 A westbound right-b.lm pocket at the intersection ofHarborBoulevard and l" Street will be constructed as part of the proposed Project. LINSCOTT, LAW &GREENSPAN, enginer;rs (J) Year2028 Plus Project (4) Traffic Conditions Ei:ceeds LOS Thresholds ICU/HCM LOS Increase Ye,JNo 0.781 C 0,011 No 0.791 C 0.010 No 0,805 D 0.004 No 0.837 D -0.027 No LLG Ref. 2-23-4737-1 Fi Ill Harbor Mixed-Use Project, Santa Ana Exhibit 9 6.0 SITE ACCESS AND INTERNAL CIRCULATION EVALUATION 6.1 Site Access Access to the Project will be provided via one (!) right-turn in/out only driveway on Harbor Boulevard and two (2) driveways restricted to left-turns/right-turns in, and right-turns out, on Figueroa Street. Table 6-1 summarizes the intersection level of service results for the three (3) proposed Project driveways under Existing and near-term (Year 2028) traffic conditions at completion and full occupancy of the proposed Project based on the HCM methodology. As shown, these Project driveways are forecast to operate at LOS D or better during the AM peak hour and PM peak hour. As such, Project access would be adequate. Motorists entering and exiting the Project site would be able to do so without undue congestion. Furthermore, the anticipated queues at each of the Project driveways are anticipated to be no more than one (I) vehicle during the AM and PM peak hours. Appendix C presents the existing and near-term HCM/LOS calculations for the three (3) Project driveways. LINSCOTT, l.Aw&GREENSPAN, engineers 23 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project. Santa Ana N· ,--1700\nH7J7 • First Harbor :,.fi��d Use. S.mta Ana1R�po1t147J7 F1rs1 !-fa l>or �11��d-Usc. S:m1.,.1 .\na Traffic Stud,· \0-23-2J do,; Exhibit 9 TABLE 6-1 PROJECT DRIVEWAY PEAK HOUR INTERSECTION CAPACITY ANALYSIS Key Intersection Harbor Boulevard at A. Project Driveway No. 1 B. Figueroa Street at Project Driveway No. 2 (North) Figueroa Street at C. Project Driveway No. 3 (South) Notes· •s/v = seconds per vehicle LINSCOTT, l.Aw & GREENSPAN, engineers Intersection Time Control Period One-Way AM Stop PM One-Way AM Stop PM One-Way AM Stop PM 24 (I) (2) Existing Year2028 Plus Project Plus Project Traffic Conditions Traffic Conditions HCM LOS HCM LOS 15.4 s/v C 16.1 s/v 24.6 s/v C 27.1 s/v D 8.4 s/v A 8.4 s/v A 8.5 s/v A 8.5 s/v A 8.5 s/v A 8.5 s/v 8.6 s/v A 8.6 s/v A LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N A70(i22JHJ7 -F,m Harbor M,,.ed t:w, Sant� A11a'R�po11'4737 F11�11-for!,or M,x�d-USI!, SanL1 .\na Traffic Stud�· 1◊-2J-2�.doc Exhibit 9 6.1.1 Traffic Gap Assessment To supplement the level of service analysis, a traffic gap analysis was conducted along Harbor Boulevard, as well as at the intersection of Figueroa Street at I'' Street, to determine if the existing traffic gaps along the main arterial roadways are considered adequate to accommodate egress at the proposed Project driveways. For the purposes of this study, it is assumed that the minimum time for one vehicle to complete the outbound right-tum movement and outbound left-tum movement is 7 seconds and IO seconds, respectively. These duration criteria were derived from empirical data collected by LLG from prior studies, and are considered conservative when compared against Table 405. IA of the Caltrans Highway Design Manual, which indicates a minimum of 6.5 seconds is required for a passenger vehicle to complete a right-tum from a stop, and a minimum of 8.5 seconds is required for a passenger vehicle to complete a left-tum from a stop when crossing three lanes. Table 6-2 presents a summary of the results from traffic gap observations/surveys performed in September 2023 for the westbound right-tum movement at the intersection of Harbor Boulevard at Project Driveway No. I, and the southbound right-tum movement at the intersection of Figueroa Street at I st Street. Table 6-2 indicates that based on the gap surveys, traffic gaps along northbound Harbor Boulevard and on westbound !st Street (that meet the duration criteria described previously) were observed to occur more frequently compared to the number of times a vehicle would be exiting the Project site using the driveway off Harbor Boulevard, or a vehicle exited/would be exiting from southbound Figueroa Street, to enter into/merge with the traffic stream already on Harbor Boulevard and I st Street. Based on these empirical results, it is reasonable to conclude that there would be an adequate number of available gaps in traffic to accommodate right-turning vehicles from the Project site onto Harbor Boulevard, and from southbound Figueroa Street onto westbound I st Street. Table 6-3 summarizes the results of the traffic gap analysis for the southbound left-tum movement at the intersection of Figueroa Street at 1st Street. Table 6-3 indicates that based on the gap surveys, traffic gaps along !st Street (that meet the duration criteria described previously) were observed to occur more frequently compared to the number of times a vehicle exited/would be exiting from southbound Figueroa Street to enter into/merge with the traffic stream already on I st Street. Based on these empirical results, it is reasonable to conclude that there would be an adequate number of available gaps in traffic to accommodate left-turning vehicles from southbound Figueroa Street onto eastbound I st Street. As described previously, Project-specific improvements are planned for implementation at the intersection of Harbor Boulevard and !st Street (Intersection No. 2) that were previously approved by the City. As part of those improvements, the Project will be adding a right-tum pocket (with a total length of 213 feet, comprised of 186 feet of storage length, and 27 feet of transition length) along I st Street on the westbound approach of the intersection. The additional roadway capacity on westbound 1st Street due to the provision of the future right-tum pocket could help increase the number of available traffic gaps that would facilitate southbound right-turns from Figueroa Street onto I st Street. LINSCOTT, LAW & GREENSPAN, engineers 25 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit 9 TABLE 6-2 RIGHT• TURN Our VEHICLE GAP ANALYSIS Harbor Boulevard at Project Driveway No. 1 (Westbound Right-Turn) Figueroa Street at P1 Street(Southbound Right-Tum) AM Peak Hour (7AM-8AM) PM Peak Hour (SPM-6PM) AM Peak Hour (7AM -8Al\[) PM Peak Hour (5PM-6PM) Gaps Total Gaps Total Gaps Total Gaps Total Vehicles Occurring Vehicles Vehicles Occurring Vehicles Vehicles Occurring Vehicles Vehicles Occurring Vehicles Served During that could Served During that could Served During that could Served During that could Gap8 by Peak b, by .... b, by .... b, by . ... b, (seconds) Gap9 Hour!U Served11 Gap9 Hour10 Served11 Gap9 Hour10 Served11 Gap9 Hour10 Served11 " " " 7-13 I 59 59 I 45 45 I 52 52 I 17 17 14-20 2 21 42 2 24 48 2 19 38 2 9 18 21-27 3 7 21 3 16 48 3 12 36 3 I 3 :::2s 4 20 80 4 9 36 4 17 68 4 3 12 Total Vehicles that Total Vehicles that Total Vehicles that Total Vehicles that could be 202 could be 177 could be 194 could be so Accommodated by Accommodated by Accommodated by Accommodated by Traffic Gaps Traffic Gaps Traffic Gaps Traffic Gaps Total Vehicles Exiting Total Vehicles E:s:iting Total Vehicles Exiting Total Vehicles Exiting the Project11 33 the Project11 38 the Project & Figueroa 49 the Project & Figueroa 43 Streetn Street11 Adequate Traffic Yo, Adequate Traffic y., Adequate Traffic Yo, Adequate Traffic y., Gaps? Gaps? Gaps? Gaps? A gap is defined as the time interval between cars crossing the Projectdriveway/minorstreet. For puiposes of this study, it is assumed the minimum time for one vehicle to complete a turning movement out of the Project driveway is 7 seconds, which was derived from empirical data collected by LLG. Per Ta hie ./OS.IA of the Caltrans Highway Design Manual, a minimum of6.5 seconds is required for a passenger vehicle to complete a right-tum from a stop, so an assumption of7 seconds is considered conservative. Values are based on gap survey performed on Wednesday September 27, 2023. Total Vehicles that could be Served= (Number of Vehicles Served) x (Number of Gaps During Peak Hour) Total vehicles exiting is based on Year 2028 Plus Project traffic conditions traffic volumes, Although Figueroa al I" Street is not a study intersection, ex:isting counts were collected at the intersection for the purposes of this gap analysis. LINSCOTT, LAW & GREENSPAN, engineer.. ' LLG Ref. 2-23-4737-1 26 First Harbor Mixed•Use Project, Santa Ana Exhibit 9 13 14 IS 16 17 TABLE6-3 LEFT. TURN Our VEHICLE GAP ANALYSIS Figueroa Street at !51 Street (Southbound Left�Turn) AM Peak Hour (7 AM -8AM) PM Peak Hour (5PM-6PM) Gaps Total Gaps Total Vehicles Occurring Vehicles Vehicles Occurring Vehicles Served During that Served During that Gap13 by Peak could be by Peak could be (seconds) Gap14 Hour15 Served16 Gapt4 Hour15 Served16 10-19 I 47 47 I 15 15 20-29 2 16 32 2 6 12 30-39 3 7 21 3 2 6 2: 40 4 4 16 4 0 0 Total Vehicles that Total Vehicles that could be 116 could be 33 Accommodated by Accommodated by Traffic Gaps Traffic Gaps Total Vehicles Exiting Total Vehicles Exiting the Project & Figueroa 28 the Project & Figueroa 20 Street17 Street17 Adequate Traffic Yes Adequate Traffic Yes Gaps? Gaps? A gap is defined as the time interval bet\Veen cars crossing the Project driveway/minor street. For purposes of this study, it is assumed the minimum time for one vehicle to complete a turning movement out of the Project driveway is 10 seconds, which was derived from empirical data collected by LLG. Per Table 405.JA of the Caltrans Highway Design Manual, a minimum of 8.5 seconds is required for a passenger vehicle to complete a left•tum from a stop when crossing three lanes, so an assumption of IO seconds is considered conseivative. Values are based on gap suivey perfonned on Wednesday September 27, 2023. Total Vehicles that could be Seived = (Number of Vehicles Seived) x (Number of Gaps During Peak Hour) Total vehicles exiting is based on Year 2028 Plus Project traffic conditions traffic volumes. Although Figueroa at I st Street is not a study intersection, existing counts were collected at the intersection for the purposes of this gap analysis. LINSCOTT, LAw& GREENSPAN, engineers 27 LLG Re£ 2-23-4737-1 First Harbor Mixed.Use Project, Santa Ana N. 1�700\11H737 -first H:ubor 1'-li��d l!�. S:mta ,\na\R�po1t'-17J7 Fust Haibor ;I.I1��d-U� Sai1L1 ,\n� Traffic StuJy 10-23-23 doc Exhibit 9 6.2 Internal Circulation Evaluation Based on our review of the preliminary site plan, driveway lengths are sufficient such that access to parking spaces would not be impeded by internal vehicle queuing/stacking. Curb return radii have been confirmed and are adequate for service/delivery trucks and trash trucks. The circulation on each level of the parking structure is adequate, with sufficient sight distance along the drive aisles. 6.3 Sight Distance Evaluation At intersections and/or Project driveways, a substantially clear line of sight should be maintained between the driver of a vehicle waiting at the crossroad and the driver of an approaching vehicle. Adequate time must be provided for the waiting vehicle to either cross all lanes of through traffic, cross the nearby lanes and turn left, or turn right, without requiring through traffic to radically alter their speed. A sight distance evaluation has been performed for the three (3) Project driveways located along Harbor Boulevard and Figueroa Street, as well as the intersection of Figueroa Street and I st Street. The Sight Distance Evaluation prepared for the Project driveways is based on the criteria and procedures set forth by the California Department of Transportation (Caltrans) in the State's Highway Design Manual (HDM). Corner sight distance was utilized for the evaluation. Corner sight distance is defined in the Caltrans HDM to be the distance required by the driver of a vehicle, traveling at a given speed, to maneuver their vehicle and avoid an object without radically altering their speed. Line of sight for corner sight distance is to be determined from a 3 ½ foot height at the location of the driver of a vehicle on a minor road to a 4¼ foot object height in the center of the approaching lane of the major road. Based on the criteria set forth in Table 405.IA of the Caltrans HDM and a posted speed limit of 40 mph on Harbor Boulevard, a corner sight distance of 382 feet for right-turning vehicles is required for Project Driveway I. Based on the criteria set forth in Table 405.IA of the Caltrans HDM and a prima facie speed limit of 25 mph on Figueroa Street, a corner sight distance of239 feet is required for right-turning vehicles at Project Driveways 2 and 3. Based on the criteria set forth in Table 405.IA of the Caltrans HDM and a prima facie speed limit of 40 mph on 1 st Street, a corner sight distance of 382 feet is required for right-turning vehicles. For left-turning vehicles, a corner sight distance of 434 feet is required when looking to the left and 492 feet is required when looking to the right. Figure 6-1 presents the results of the sight distance evaluation for right-turning vehicles at Project Driveway I based on the application of the corner sight distance criteria. The figure illustrates the limited use areas. As shown, the sight lines at the proposed Project driveway are expected to be adequate as long as obstructions within the sight triangles are minimized. LINSCOTT, lAW & GREENSPAN, engineers 28 LLG Re( 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N' ,4700\2234737 -Fir�t lfarbor i\f1x�d u�e. Sant� ,\na' Repo,11�737 Fii�t l!arbm �li,.�d-Use, Sn11t.1 .\n;t Trnfiic St11dy l0-2J-2J.doc Exhibit 9 Figure 6-2 presents the results of the sight distance evaluation for right-turning vehicles at Project Driveways 2 and 3 based on the application of the comer sight distance criteria. The figure illustrates the limited use areas. As shown, the sight lines at the two (2) Project driveways will be obstructed by vehicles parked on-street along Figueroa Street. Based on this, it is recommended to restrict on street parking along the segment of Figueroa Street adjoining the Project site to help facilitate traffic flows, and enhance visibility for southbound traffic on Figueroa Street and Project traffic exiting the driveways. Figures 6-3 and 6-4 present the results of the sight distance evaluation for southbound right-turning vehicles and southbound left-turning vehicles, respectively, at the intersection of Figueroa Street and 1st Street based on the application of the comer sight distance criteria. The figure illustrates the limited use areas. As shown, the sight lines for southbound right-turning and left-turning vehicles on Figueroa Street are expected to be adequate as long as obstructions within the sight triangles are minimized. LINSCOTT, LAW & GREENSPAN, engineers 29 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N A700,22J.l7J7 • Fn$1 Ha,bor \hxcd l'.Si!. Sanu -\na'R1lpo,t'H37 F1f51 Harl-or .\11).cd-\;S<e. Sant.1 .\na Tmffic Study I0-13-2J.doc Exhibit 9 SIGHT DISTANCE DESIGN SPEED LIMIT: REQUIRED CORNER SIGHT DISTANCE: 40 MPH 382 FEET -., LEGEND � PUBUC RJCHT-OF-WAY I.hi/TIT) US£ ARCA· TO £NSl/l?E AD£0UATE SIGHT OISTANC£, fW?OSCAP£ ANO/OR IANOSCA/'£ SH'J.L NOT 8£ HICHER THAN JO INCHES ABO\£ TH£ CUR8/SIO€WALJ(, NO ITNC£S OR WALLS IN UMITElJ use AR£A II I f -r:;-t �, .. 1--, --'--+---u SOURCE: PRIMIOR FIGURE 6-1 HARBOR BOULEVARD SIGHT DISTANCE ANALYSIS FIRST HARBOR MIXED-USE PROJECT, SANTA ANA f Exhibit 9 I� �O SCALE SIGHT DISTANCE DESIGN SPEED LIMIT: REQUIRED CORNER SIGHT DISTANCE: 25 MPH 239 FEET LEGEND � PU8UC RIGHT-OF-WA< LJMITll) US£ AR£:A: TO £NS/JR£ AIJCOllATC S/CHT DISTANCE, HAROSCAP£ ANO/OR lANOSCAff SH<l.L NOT 8£ HIGHER f>IAN JO INCH£:S ABO>!' TH£ C/JR8/SIOCWALX. NO F£:NC£:S OR WALLS IN UAIITCO /JS£ ARDl SOURCE: PRIMIOR FIGURE 6-2 FIGUEROA STREET SIGHT DISTANCE ANALYSIS FIRST HARBOR MIXED-USE PROJECT. SANTA ANA Exhibit 9 SIGHT DISTANCE DESIGN SPEED UMIT: REQUIRED CORNER SIGHT DISTANCE LOOKING LETT: 40 MPH 382 FEET LEGEND � PUBUC RIGHT-OF-WAY L/1,i/TITJ US£ ARE:A.· ro ENSURE A/)£OIJA TE S!CHT OISWICC. HAROSCAPE: ANO/OR I.ANOSCAPE: SH,ILL I/OT BE: HICHE:R THAN JO INCHES ABO\£ THE CUR8/SJOEWALX. NO FENCES OR WALLS IN LIMITE:0 USE: AR£A. SOURCE: PRIMIOR FIGURE 6-3 FIGUEROA STREET AT 1ST STREET SOUTHBOUND RIGHT SIGHT DISTANCE ANALYSIS FIRST HARBOR MIXED-USE PROJECT, SANTA ANA f Exhibit 9 SIGHT DISTANCE 0£SIGN SPEED Ut,UT: REQUIRED CORNER SIGHT DISTANCE L()()l(ING LEn: REQUIRED CORNER SIGHT DISTANCE LOOKING RIGHT: -J�] rt· pn .. .r;.+:;-: . -';.. : ...., ... � � . . ' . -�fl11UWI • • ' J I • 40 MPH 434 FEET 492 FEET LEGEND t7222l �'#ff �11�-�olf:1/°s,::f OISTANCC. HAROSCAP£ ANO/OR LA/VOS� 51{4LL NOT 8£ HICH£R THAN JO INCHES ABO>£ TH£ CIJRB/SIOEWAJ.J(. NO Ff:NC£S OR WALLS IN UMrTEO /JS£ AREA SOURCE: PRIMIOR FIGURE 6-4 FIGUEROA STREET AT 1ST STREET SOUTHBOUND LEFT SIGHT DISTANCE ANALYSIS FIRST HARBOR MIXED-USE PROJECT, SANTA ANA Exhibit 9 7 .0 INTERSECTION TURN POCKET QUEUING ANALYSIS To validate the adequacy of stacking provided for the northbound left-turn/"U-turn" lane located at the intersection of Harbor Boulevard and 5th Street, as well as the southbound left-turn/"U-turn" lane, westbound dual left-turn lanes, and future Project-specific improvement of a westbound right turn lane located at the intersection of Harbor Boulevard and I st Street, a queuing evaluation was conducted under Existing, Existing plus Project, Year 2028 Cumulative Base and Year 2028 Cumulative plus Project traffic conditions. The Highway Capacity Manual 6th Edition (HCM 6) methodology was utilized to confirm the adequacy of vehicular stacking for the aforementioned turn lanes located at the intersections of Harbor Boulevard and 5th Street, and Harbor Boulevard and I st Street. Tables 7-1 and 7-2 present the queueing results. Existing Plus Project and Year 2028 Plus Project traffic conditions presume the Project-specific improvement (i.e., addition of an exclusive right-turn pocket on the westbound approach) at the intersection of Harbor Boulevard and I st Street. Tables 7-1 and 7-2 indicate that adequate queue storage length is currently provided for the northbound left-turn/"U-turn" lane located at the intersection of Harbor Boulevard and 5th Street based on the anticipated maximum 95th percentile queue length under Existing, Existing plus Project, Year 2028 Cumulative Base, and Year 2028 Cumulative plus Project traffic conditions. Although the existing and future 95th percentile queues reported for the southbound left-turn/"U turn" and westbound left-turn movements at the intersection of Harbor Boulevard and I st Street exceed the existing storage lengths for the respective movements, these are existing queue storage deficiencies not caused by the Project. The 95th percentile queue lengths are conservative estimates of potential queues because, given 30 signal cycles per hour (based on a cycle length of 120 seconds), the 95th percentile queue might form in only 1.5 cycles during the peak hour. It should be noted further that the Project-generated traffic that could be added to the southbound and westbound left-turn movements are nominal (i.e., southbound left-turn: 15 AM peak hour trips, 36 PM peak hour trips; westbound left-turn: 11 AM peak hour trips, 16 PM peak hour trips), corresponding to a maximum of one vehicle on a given cycle. Tables 7-1 and 7-2 indicate that adequate queue storage length would be provided for the planned westbound right-turn pocket at the intersection of Harbor Boulevard and J st Street based on the anticipated maximum 95th percentile queue length under Existing plus Project, and Year 2028 Cumulative plus Project (during the AM peak hour only) traffic conditions. Although the future 95th percentile queue length of 232 feet during the PM peak hour would exceed the proposed pocket length of 213 feet, there is an additional 27 feet of queue storage on westbound I'' Street between the end of the future right-turn pocket and Figueroa Street that would result in a total storage length of240 feet, which could accommodate the forecasted queue length of232 feet. LINSCOTT, LAw&GREENSPAN, engineers 30 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit 9 Based on the considerations above, improvements are not recommended. Appendix D provides the queuing calculation worksheets for Harbor Boulevard at 5th Street and Harbor Boulevard at I st Street. LINSCOTT, LAW & GREENSPAN, engineers 31 LLG Re[ 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana :-; 47U0\223--17J7 -First fl1rbor .\.�;,.ed l'se. S:rnta Ana'Report'4737 F,,;1 Harlxir :\10,.:d-Use, Santa ,\na TrJ!fo; Stud) I 0-23-23 dDc Exhibit 9 Key Intersections I. Harbor Boulevard at 5th Street Northbound Left-Tumf'U-tum" 2. Harbor Boulevard at 1•tstreet Southbound Left-Tumf'U-tum" Westbound Dual Left-Tum Future Westbound Right-Turn20 18 Source_: Google Earth. Storage Provided 18 (ft) 185" 245" 3IO' 213•21 TABLE 7-1 EXISTING PLUS PROJECT QUEUING ANALYSIS (I) Existing Traffic Conditions AM Peak Hour PM Peak Hour Max, Adequate Max. Adequate Queue19 Storage Queue19 Storage (ft.) Yes/No (ft.) Yes/No 43' Yes 113' Yes 293' No 410' No 296' Yes 332' No ------- 19 Maximum queue in feet (ft) is calculated by taking the 95"' Percentile Queue length (ft) in HCM 7. A westbound right-tum pocket at the intersection ofHaroorBoulevard and I" Street will be constructed as part of the proposed Project. 21 Based on prciposed Site Plan prepared by Primior. LINSCOTT, I.Aw & GREENsPAN, engineers 32 (2) Existing Plus Project Traffic Conditions AM Peak Hour PM Peak Hour Max. Queue19 (ft.) 54' 311' 316' 206' Adequate Storage Yes/ No Yes No No Yes Max. Adequate Queue19 Storage (ft.) Yes/No 123" Yes 493' No 394' No 213' Yes ' LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit 9 TABLE 7-2 YEAR 2028 PLUS PROJECT QUEUING ANALYSIS (I) Year 2028 Traffic Conditions AM Peak Hour PM Peak Hour Storage Max. Adequate Max. Adequate Provided Queue" Storage Queuell Storage Key Intersections n (ft.) (ft.) Yes/No (ft.) Yes/No I. Harbor Boulevard at 5th Street Northbound Left-Tum/"U-tum" 185' 50' Yes 141' Yes 2. Harbor Boulevard at I st Street Southbound Left-Tumf'U-tum" 245' 306' No 484' No Westbound Dual Left-Tum 310' 316' No 382' No Future Westbound Right-Tumu 213'25 ---- Source: Google E:orth. u n Maximum queue in feet (ft) is calculated by taking the 95'" Percentile Queue length (ft) in HCM 7. 24 A westbound right-Wm pocket at the intersection of Harbor Boulevard and I" Street will be constructed as pan of the proposed Project. 25 Based on proposed Site Plan prepared by Primior. (2) Year2028 Plus Project Traffic Conditions AM Peak Hour PM Peak Hour Max. Adequate Max. Adequate QueueU Storage Queuel-' Storage (ft.) Yes/No (ft.) Yes/No 67' Yes 156' Yes 336' No 550' No 344' No 438' No NoError! 211' Yes 232' Book:mar knot defined. Error! Bookmark not defined. Although the future 95th percentile queue length of232 feet during the PM peak hour would exceed the proposed pocket lenb>th of213 feet, there is an additional 27 feet of queue storage on westbound 1• Street between the end of the future right-tum pocket and Figueroa Street that would result in a total storage length of240 feet. which oould accommodate the forecasted queue length of232 feet. LINSCOTT, LAW & GREENSPAN, engineets 33 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana Exhibit 9 8.0 CONGESTION MANAGEMENT PROGRAM (CMP) COMPLIANCE ASSESSMENT This analysis is consistent with the requirements and procedures outlined in the current Orange County Congestion Management Program (CMP). The CMP requires that a traffic analysis be conducted for any project generating 2,400 or more daily trips, or 1,600 or more daily trips for projects that directly access the CMP Highway System (HS). As noted in Section 4.0 of this traffic study, the proposed Project is forecast to generate approximately 1,575 daily trip-ends, and therefore, does not require a CMP traffic analysis. The CMPHS includes specific roadways, which include State Highways and Super Streets, which are now known as Smart Streets. Therefore, the CMP traffic analysis requirements relate to the potential circulation effects only on the specified CMPHS. The intersection of Harbor Boulevard and I st Street (Intersection No. 2) is a CMP intersection, which would have required evaluation if the CMP threshold was exceeded. It should be noted that the City of Santa Ana LOS criteria and evaluation identified in Section 5.0 of this report is consistent with the Orange County CMP traffic analysis guidelines. The level of service results for the intersection are summarized in Tables 5-1 and 5-2 and indicate that the proposed Project will not require improvements at this location. LINSCOTT, LAW & GREENSPAN, engineers 34 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N . ...t700'.'.?:J47J7 - F11s1 !farbor \hx,:d U,,,e. S:mta A11a'R�rt'4737 First llarbor M1A.:d-L'se. S:mtl .\n� Traffic Stu.!; 10-13-D.doc Exhibit 9 9.0 ROADWAY SEGMENT EVALUATION Per City of Santa Ana requirements, this section of the report analyzes the daily operating conditions of key roadway segments within the vicinity of the proposed Project. A total of one(!) key roadway segment within the City of Santa Ana have been selected for evaluation and consist of the following locations: A.Figueroa Street, between 5th Street and I st Street (City of Santa Ana) 9.1 Roadway Link Capacities The City of Santa Ana utilizes the methodology presented in the County Master Plan of Arterial Highways (MP AH) and the City of Santa Ana Circulation Element to determine LOS midblock locations, as summarized in Table 9-1. 9.2 Roadway Link Level of Service Criteria According to the City of Santa Ana, LOS D is the minimum acceptable condition that should be maintained for roadway segments. However, the City of Santa Ana has defined exceptions to this criteria in major development areas where LOS E is considered acceptable If the daily roadway V /C ratio results in unacceptable LOS conditions, a peak hour link analysis is conducted to determine if the roadway operates at a satisfactory service level during the peak hours. LINSCOTT, LAw&GREENSPAN, engineers 35 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana N \.j.700\1�34737 -First Harbor :-.riwd Us,;,. Sant� A11n1Repc>1t147J7 First lfaibor Mixcd-U5e. Santa .\na Tmffic Stl1dy 1().23.23 doc Exhibit 9 TABLE 9-1 ROADWAY SEGMENT CAPACITIES AND LEVEL OF SERVICE CRITERIA" Roadway Capacities Roadway Classification Lanes LOSA LOSB LOSC LOSD LOSE LOSF Principal Arterial 8D 45,000 52,500 60,000 67,500 75,000 >75,000 Major Arterial 6D 33,900 39,400 45,000 50,600 56,300 >56,300 Primary Arterial 4D 22,500 26,300 30,000 33,800 37,500 >37,500 Secondary Arterial 4U 15,000 17,500 20,000 22,500 25,000 > 25,000 Divided Collector 2D 9,000 12,000 15,000 20,000 22,000 > 22,000 Collector 2U 7,500 8,800 10,000 11,300 12,500 >12,500 26 Source: Guidance for Administration of the Orange County Master Plan of Arterials and Highways (2017). LINSCOTT, LAW & GREENSPAN, engineers 36 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Project, Santa Ana � ,-t70011:C.Jn37 -F1rs1 H:ubor \!iwd l;si!. Santa Ana'R-,,011'.1737 First H.trl\Cr M,�cd-U,e. Sa11ta .\n� Tr:iffic Study 10-23-2..l do,: Exhibit 9 9.3 Roadway Segment Analysis Results 9.3.1 Existing Plus Project Analysis Table 9-2 summarizes the results of the Existing Plus Project daily analysis for the one (1) key roadway segment. The first column (1) in Table 9-2 presents a summary of existing daily traffic conditions. The second column (2) lists existing traffic conditions with the addition of traffic generated by the proposed Project. The third column (3) indicates whether the traffic associated with the Project will exceed the level of service thresholds defined in this report. Existing Traffic Conditions Review of Column I of Table 9-2 indicates that the one (1) key roadway segment currently operates at acceptable LOS A. Existing Plus Project Traffic Conditions Review of Columns 2 and 3 of Table 9-2 indicates that the one (I) key roadway segment is forecast to continue to operate at an acceptable service level on a daily basis with the addition of Project generated traffic to existing traffic and will not require improvements when compared to the LOS standards and thresho.lds specified in this report. ltNSCOTT, I.Aw & GREENSPAN, engineers 37 LLG Ref. 2-23-4737-1 First Harbor Mixed•Use Project, Santa Ana N ·--1700'22H7J7 -F1rs1 Harbor ,\[1,-.,d u�. S:mt� ,\na'R"J:'Ort'-H37 Fim !far!'Or :-.11�.,d-t.;se. Santa ,\n:t Traffic Stud,- 10-2J-2J.WC Exhibit 9 TABLE9•2 ExiSTING PLUS PROJECT ROADWAY SEGMENT LEVEL OF SERVJCE SUMMARY (1) Eiisting Min. Traffic Conditions Acceptable Roadway No. or Daily LOS u Roadwav S........,ent Jurisdiction LOS Classification Lanes Volume A.Figueroa Street, between Santa Ana D Collector 2U 903 A 5lh Street and I"' Street LINSCOTT, LAW &GREEtlSPAN, engineers 38 (2) (3) Exceeds Existing Plus Project LOS Traffic Conditions Threshold Daily LOS Yes/No Volume 1,523 A No LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana Exhibit 9 9.3.2 Year 2028 Plus Project Analysis Table 9-3 summarizes the results of the Year 2028 Plus Project daily analysis for the one (I) key roadway segment. The first column (I) in Table 9-3 presents a summary of Year 2028 Cumulative daily traffic conditions. The second column (2) lists Year 2028 Cumulative traffic conditions with the addition of traffic generated by the proposed Project. The third column (3) indicates whether the traffic associated with the Project will exceed the level of service thresholds defined in this report. Year 2028 Cumulative Traffic Conditions Review of Column I of Table 9-3 indicates that the one (I) key roadway segment is forecast to operate at acceptable LOS A with the addition of ambient traffic growth and cumulative projects traffic. Year 2028· Cumulative Plus Project Traffic Conditions Review of Columns 2 and 3 of Table 9-3 indicates that the one (I) key roadway segment is forecast to continue to operate at an acceptable service level on a daily basis with the addition of Project generated traffic in the Year 2028 and will not require improvements when compared to the LOS standards and thresholds specified in this report. LINSCOTT, LAW & GREENSPAN, enginee,s 39 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana N 147Q(J\22J�7J7 - F11s1 1-farbor M1\�d L'S!!, S:mt� Ana'R�poirl,1737 F11st I fo.rbor Mt�id-l/s�. Santa An� Tr;1ffic Study 10-23-ZJ do� Exhibit 9 TABLE9-3 YEAR 2028 ROADWAY SEGMENT LEVEL OF SERVICE SUMMARY (I) Year2028 Traffic Conditions Min. Acceptable Roadway No.of Daily LOS Ke--Roadwr Se-ment Jurisdiction LOS Classification Lanes Volume A Figueroa Street, between 5th Street and 151 Street Santa Ana D Collector 2U 948 A LINSCOTT, LAW & GREENSPAN, engineers 40 (2) (J) Year 2028 Exceeds Plus Project LOS Traffic Conditions Threshold Daily LOS Yes/No Volume 1,568 A No LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana Exhibit 9 10.0 CEQA ASSESSMENT OF VMT, ACTIVE TRANSPORTATION, & PUBLIC TRANSIT 10.1 Vehicle Miles Traveled (VMT) Screening Analysis The purpose of this Vehicle Miles Traveled (VMT) analysis is to evaluate the Project based on Senate Bill 743 (SB 743) requirements, as required in CEQA section 15064.3. The City of Santa Ana has adopted criteria for evaluating VMT impacts under CEQA, and they are presented in the City of Santa Ana Traffic Impact Study Guidelines (September 2019). There are three types of screening methods to effectively screen projects from project-level assessment: (I) Transit Priority Area (TPA) Screening; (2) Low VMT Area Screening; (3) Project Type Screening. Projects located within a TP A may be presumed to have a less-than-significant impact on VMT absent substantial evidence to the contrary. A TPA is defined as a half-mile area around an existing "major transit stop" (i.e., a site containing an existing rail transit station, ferry terminal served by bus or rail transit service, or the intersection of two or more major bus routes with a frequency of service interval of 15 minutes or less during the morning and afternoon peak commute periods), or an existing stop along a "high-quality transit corridor" (i.e., a corridor with fixed route bus service with service intervals no longer than 15 minutes during peak commute hours). To identify if a project is in a TPA, Appendix A (Santa Ana Transit Priority Areas) of the City's guidelines is reviewed. Residential and office projects located within a low VMT-generating area may be presumed to have a less-than-significant impact absent substantial evidence to the contrary. In addition, other employment-related and mixed-use land use projects may qualify for the use of screening if the project can reasonably be expected to generate VMT per resident, per worker, or per service population that is similar to the existing land uses in the low VMT area. To identify if a project is in a TPA, Appendix B (VMT/SP in Santa Ana as Compared to Orange County Average) and Appendix C (Santa Ana Development Areas that Cannot Be Screened) of the City's guidelines are used. Some project types have been identified as having the presumption of a less-than-significant impact absent substantial evidence to the contrary because their uses are local serving in nature, including local-serving retail uses with less than 50,000 SF, and projects generating less than 110 net daily trips. Based on the application of the City's screening criteria described above, and using Appendices A, B, and C in the City's guidelines, it was determined that the Project is located in a TPA (as shown on Figure 10-1) and is located in a low-VMT generating area (as shown on Figures 10-2 and 10-3); and is therefore screened out from further VMT project-level assessment because it can be presumed to have less-than-significant impact on VMT. 10.2 Active Transportation and Public Transit Screening Analysis Even though the City's traffic impact analysis guidelines do not specify the need for Active Transportation and Public Transit Screening Analysis, potential impacts to active transportation LINSCOTT, LAw&GREENSPAN, engineers 41 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Development. Santa Ana N ,-l70DU2J47J7 -First Haib"r Mi��d t;,�. SJnta Ana'R�po1t'47J7 First H.ul'Clr )..\,��d-Fse. Santa .-\n� TrJffic Stl1dy 10-}3-23,doc Exhibit 9 --OC Metrolink Rail Half Mile Buffer around Metrolink Station Half Mile around High Quality Bus Stops Santa Ana SOURCE: CITY OF SANTA ANA �O SCALE FIGURE 10-1 SANTA ANA TRANSIT PRIORITY AREAS FIRST HARBOR MIXED-USE PROJECT, SANTA ANA 9 r "! I 0 Exhibit 9 Garden Grove I / Fountain Valley Costa Mesa < -15% below OC Regional Average 0 to -15% below OC Regional Average -Higher than the OC Regional Average LINSCOTT LAW & GREENSPAN engineerc; �O SCALE Tustin Santa Ana " Edinger Ave Warner Ave MacArthur Blvd Irvine fg () SOURCE: CITY OF SANTA ANA FIGURE 10-2 VMT/SP IN SANTA ANA AS COMPARED TO ORANGE COUNTY AVERAGE FIRST HARBOR MIXED-USE PROJECT, SANTA ANA ;:i 0 N I ;:i I � "'.... <ii N <O Q. 9 "' • '! N I 0 " ....".. / "' • l 2 C � :f, � ·e5 e 0 " � "...." ...... "' "'/ R .. / c Exhibit 9 Santa Ana TAZ VMT/ SP not at least 15% below County Average and is not inside of a Transit Priority Area SOURCE: CITY OF SANTA ANA FIGURE 10-3 SANTA ANA DEVELOPMENT AREAS THAT CANNOT BE SCREENED FIRST HARBOR MIXED-USE PROJECT, SANTA ANA ,,, g N I ,,, N I 0 9 ! ..; I 0 Exhibit 9 (pedestrian and bicycle) and public transit facilities and circulation were evaluated in this report by determining whether the Project conflicts with adopted policies, plans, or programs regarding public transit, bicycle, or pedestrian facilities, or otherwise decreases the performance or safety of such facilities. Sidewalks are provided on both sides of the street throughout most of the City. Crosswalks, pedestrian push buttons, and pedestrian indication lights are provided at all signalized intersections adjacent to the Project site. The proposed Project plans to retain this existing pedestrian infrastructure. The proposed Project will encourage walking by integrating pedestrian connections internally, as well as to nearby activities. Pedestrian circulation would be provided via existing public sidewalks along Harbor Boulevard, 1st Street, and Figueroa Street within the vicinity of the Project. The proposed Project will protect the existing sidewalk along Project frontage on these roadways. The existing sidewalk system within the Project vicinity provides direct connectivity to the existing development located along major thoroughfares. Long-term bicycle storage for the residential and retail uses will be provided in two bike rooms, totaling 96 long-term bike spaces. An additional four ( 4) bicycle spaces will be provided for short term bicycle storage purposes. According to the City of Santa Ana Bikeway Master Plan, Class IV Cycle Tracks are planned on Harbor Boulevard and I st Street along the Project's frontage. Figure 1-1 illustrates the location of public transit stops near the Project site, and Section 3.3 (Existing Public Transportation) describes the public transit-rich setting for the Project. Based on the above, the proposed Project would not have an impact on the existing multimodal network; specifically, it would not: (I) conflict with a plan, ordinance, or policy related to bicycle, pedestrian, and public transit; (2) substantially increase hazards due to a geometric design feature; or (3) result in inadequate emergency access. The proposed site plan for the Project will maintain existing sidewalks and access to public transit, construct new pedestrian connections on site and with adjoining uses, and meet City design standards regarding site access, multimodal connectivity within the internal site circulation system, emergency access, and on-site parking. LINSCOTT, LAW & GREENSPAN, engineers 42 LLG Ref. 2-23-4737-1 First Harbor Mixed.Use Development, Santa Ana N 1+700\'.'.'.'J47J7 • Firs, H,ubor Mix�d llse, Santa ,\11,1'R�1:>01t'.17J7 first I/arbor �11,ed-lisc, Santa ,\na Tr.iffic Study 10-23-23 doc Exhibit 9 11.0 PARKING ANALYSIS AND PARKING MANAGEMENT PLAN {PMP) 11.1 City Code Parking Requirements City Code parking requirements for the Project were calculated based on the parking ratios from Table 3-7 (Off-Street Parking Standards) on Page 3-11 of the October 2014 Harbor Mixed Use Transit Corridor Plan for the Transit Node District. Table 11-1 presents a summary of the parking ratios applied to calculate the City Code requirements for residents, residential guests, and non residential/retail uses. As indicated on Table 11-1, the application of Specific Plan parking ratios to the various Project components results in a total City Code requirement of 313 spaces. Comparing this Code requirement against the proposed parking supply of 333 standard spaces results in a Code-based surplus of 20 spaces. Based on this, the Project's parking supply provisions would be adequate in meeting the City Code requirements for the Project. 11.2 Parking Management Plan (PMP) A PMP defines how parking for a development would be managed and what measures would be implemented to assure that parking needs in the aggregate and in localized sub-areas would be adequately served. A TOM Program identifies measures that could potentially reduce parking needs through the provision of physical and/or operational improvements that promote the use of alternative modes of travel (i.e., public transit, bicycle, walking). Recommendations for PMP measures are provided in this study to ensure competing parking needs for all Project tenants, guests, and employees are adequately managed and controlled to facilitate parking efficiency. Implementation of PMP measures will help ensure that the Project's parking supply will be sufficient, convenient/accessible, responsive to varying demand, and provide parking contingencies in meeting the parking needs of all users (i.e., residential, retail). It is recommended that when the Property Owner and/or Property Management Company deems it necessary, the following key Parking Management Strategies be implemented by the Property Owner and/or Property Management Company: •The PMP should identify where the retail/commercial employees park within the site. •The PMP should identify where location of short-term parking spaces for service retail usesand/or food uses (take-out/curb side service, etc.). •The PMP should direct residents to park in their assigned spaces and provide parking toaccommodate resident guest parking needs. •The PMP should restrict vehicles from exceeding the time restriction on any short-term parking. •The PMP should provide rules of conduct for tenants and guests to abide by. Strict enforcementshall be adhered to. LINSCOTT, LAW & GREENSPAN, engineers 43 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana N'·.4700\2234737-Firn Harbor M,x�d L'se. Santa AnJ'R�pcn'47J7 F1rs.t H�.rbor M,x�d-l's.c,, Snnt-1 Ana Tmffic Study l0-�3-23.doc Exhibit 9 TABLE 11-1 CITY CODE PARKING REQUIREMENTS27 Spaces Project Description Size Code Parking Ratio Required Residential . Residents 183 DU I parking space for dwelling unit 183 Spaces . Residential Guests 183 DU 0.5 visitor spaces per dwelling unit 92 Spaces . Residential Guests 15,182 SF I parking space per 400 SF 38 Spaces Total Code Parking Requirement: 313 Spaces Proposed Parking Supply: 333 Spaces Total Parking Surplus(+) or Deficiency(-): +20 Spaces 27 Source: City of Santa Ana parking ratios from Table 3-7 (Off-Street Parking Standards) on Page 3-11 of the October 2014 Harbor Mixed Use Transit Corridor Plan for the Transit Node District LINSCOTT' LAW & GREENSPAN, engineers 44 LLG Ref 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana Exhibit 9 •The PMP should adopt the mindset with the following parking goals: 1.Meet or exceed the minimum requirements for total parking spaces for the Project's retail/commercial component, as well as the residential component. 2.Provide all resident and guest parking spaces onsite. 3.Provide flexible on-site parking opportunities for commercial and resident parking that respect both commercial tenants and guest parking needs. 4.Enact policies that promote parking efficiencies and effective communication between Property Management, commercial tenants and residents. 5.Enact policies of enforcement by Property Management that are sufficiently flexible to meetcurrent and changing parking demands, while imposing penalties, if necessary. 11.3 PMP Measures The following measures are available to the Project to mitigate any parking impacts or deficiencies in the event the proposed on-site parking supply is determined to be greater than what is provided. Retail/Commercial Component 1.The Property Owner/Property Management Company will implement a reciprocal parking program to ensure the pool of parking for the retail/commercial component and guest of the residential component is available to be "shared". 2.The Property Owner/Property Management Company will work with tenants of the retail uses toimplement an employee parking program, with the goal of providing convenient and accessible shopping experience for the customers of the retail uses, and to leave the most desirable parkingspaces within the parking structure for use by customers. The location of designated employeeparking spaces will be developed in collaboration between Property Owner/PropertyManagement Company and the tenants. The employee parking spaces will be identified with awhite or yellow circle, and/or other signage recommended by the the Property Owner/PropertyManagement Company. It is noted that these spaces will be open for customer use. 3.The Property Owner/Property Management Company will work with tenants of the retail uses toidentify the need for "short term/time restricted spaces" on an as need basis, dependent on theneeds of the proposed retail and/or food use. These short-term spaces will most likely bedesignated along the internal roadways. The short-term spaces may be used for "curbside/takeout" and/or for service retail-type users. The number and location of spaces will be determinedby Property Owner/Property Management Company and the potential tenants. 4.If the Property Owner/Property Management Company determines additional parking is neededto meet the parking requirements of the retail/commercial component of the Project and/ordesires to provide "enhanced customer service", the Property Owner/Property ManagementCompany shall implement a valet/valet assist program. The hours of operation of the valet/valetassist program will be determined by the Property Owner/Property Management Company, andsubject to actual demand, may include weekdays and weekends, between the period 11 :00 AMand 2:00 PM and 5:00 PM to 10:00 PM, to enhance the customer experience accommodate the"lunch time" and "dinner" crowd of the proposed restaurant/food uses. LINSCOTT, LAW & GREENSPAN, engineers 45 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana N ,-H00'1:H7J7 • F1rs1 Hmbor Miwd u,�, S:uua �na'RcpouL-1737 F11�1 H.ulior Mt>,etl-Use. Silnta .\na TrJflic Sh1dy !O-D-23.doc Exhibit 9 Residential Component 5.The Property Owner/Property Management Company shall determine the allocation of parking spaces for resident tenants and location of guest parking spaces, and assign residential parking spaces accordingly. 6.The Property Owner/Property Management Company, if deemed necessary, may allow resident guest to utilize the valet program identified in Measure No. 4, as an enhanced service. Toimplement the valet operation, the Property Owner/Property Management Company would engage the services of a well-established valet operations company similar to PMP measure No. 4. 7.Every resident will be required to register their vehicle. The registered owner must be a lease holding resident. This registration will be updated annually at the time of recertification. If valid registration is not obtained from the Property Owner/Property Management Company, the vehicle may be towed at the owners' expense. 8.Vehicles lacking current registration may be towed by the Property Owner/Property Management Company. The storage of inoperable or unregistered vehicles is prohibited. 9. If a resident obtains a new vehicle, the resident must provide new registration (transferring registration is not permissible). 10.Vehicles may not occupy unassigned spaces for more than twenty-four (24) hours, without contacting the leasing office in advance. Violators are subject to towing at the vehicle owner's expense. 1 I. Resident guests will be able to park, on a first-come-first-served basis, within the spaces designated for guest parking. 12.Violation of the PMP strategies contained herein may result in the towing of the vehicle at thevehicle owner's expense. 13.The enforcement of resident and resident guest parking on-site parking requirements summarized herein will be handled by the Property Owner/Property Management Company to ensure compliance. Retail/Commercial & Residential Component 14.To enhance efficient and comfortable movement of all users throughout the site, and access to parking spaces and valet pick-up/drop-off staging areas (if implemented), and support "Park Once" strategies, provide a detailed wayfinding/signage program that meets City standards and requirements. ltNSCOTT, LAW & GREENSPAN, engineers 46 LLG Re[ 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana Exhibit 9 15.The parking conditions for the Project will be reviewed/monitored on a quarterly basis by the Property Owner/Property Management Company and appropriate actions detailed above will be taken to ensure that the necessary PMP measures are being implemented. 16.Designate areas on site for quick and efficient pick-up and drop-off of passengers to facilitate ridesharing and use of rideshare services such as Uber and Lyft. LINSCOTT, LAW & GREENSPAN, engineers 47 LLG Ref 2-23-4737-1 First Harbor Mixed•Use Development, Santa Ana Exhibit 9 SUMMARY OF FINDINGS AND CONCLUSIONS •Project Description -The First Harbor Mixed-Use Project proposes to develop a nine-story building with 183 multifamily residential units (including studios, I-bedroom, 2-bedroom, and 3- bedroom units) and 15,182 SF of retail on the ground floor. Of the 183 total units proposed, 15% (28 units) would be designated as low-income housing. The residential and retail uses would wrap around a four-level parking structure, consisting of two subterranean levels, one street/ground level, and a second above-ground level, and provide a total of 333 standard parking spaces. As presented previously, Figure 1-1 is the Vicinity Map, which shows the general location of the Project and surrounding street system. Figure 2-1 is an existing aerial photograph of the Project site. The Project is expected to be completed and fully occupied by Year 2028. As part of the Project-specific improvements planned at the intersection of Harbor Boulevardand !st Street (Intersection No. 2) previously approved by the City, the Project will be adding aright-turn pocket (with a total length of213 feet, comprised of 186 feet of storage length, and 27feet of transition length) along I st Street on the westbound approach of the intersection. •Study Scope -The following two (2) key study intersections and one (I) key roadway segmentwere selected for detailed peak hour level of service analyses under Existing Traffic Conditions,Existing Plus Project Traffic Conditions, Year 2028 Cumulative Traffic Conditions and Year2028 Cumulative plus Project. Kev Study Intersections 1.Harbor Boulevard at 5th Street (City of Santa Ana)2.Harbor Boulevard at I st Street (City of Santa Ana) Kev Roadway Segments A.Figueroa Street, between 5th Street and I st Street (City of Santa Ana) •Existing Traffic Conditions -All key study intersections currently operate at an acceptable levelof service (LOS) during the AM and PM peak hours when compared to the LOS criteria definedin this report. •Project Trip Generation -The proposed Project is forecast to generate approximately 1,575daily trips, with 100 trips (36 inbound, 64 outbound) produced in the AM peak hour and 131trips (73 inbound, 58 outbound) produced in the PM peak hour on a "typical" weekday. •Related Projects Traffic Characteristics -Ten (10) related projects were considered as part ofthe cumulative background setting. The ten (10) related projects are forecast to generate 4,705 daily trips, with 245 trips (103 inbound, 142 outbound) anticipated during the AM peak hour and287 trips (162 inbound, 125 outbound) produced during the PM peak hour. LINSCOTT, LAW & GREENSPAN, engineers 48 LLG Ref 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana :>: . .4700 �13HJ7 -Fitsr Harbor ;l,li>..:d t·se, S:uua Ana R�µorrHJ7 Fir.<t Ha.rl>or \h>..:d-Llse. Santa .-\na Tr�ffic $1uJ} I0-23-23 doc Exhibit 9 •Existing Plus Project Traffic Conditions -The traffic associated with the proposed Project willnot require improvements at any of the two (2) key study intersections, when compared to theLOS standards and thresholds specified in this report. The two (2) key study intersections areforecast to operate at LOS D or better during the weekday AM and PM peak hours with theaddition of Project traffic. •Year 2028 Cumulative Traffic Conditions Plus Project -The traffic associated with theproposed Project will not require improvements at any of the two (2) key study intersections,when compared to the LOS standards and thresholds specified in this report. The two (2) keystudy intersections are forecast to continue to operate at acceptable levels of service (LOS D orbetter) during the AM and PM peak hours with the addition of Project traffic to Year 2028Cumulative traffic conditions. ■ Site Access Assessment -Harbor Boulevard at Project Driveway I and Figueroa Street at ProjectDriveways 2 and 3 are forecast to operate at LOS D or better during the AM peak hour and PMpeak hour. As such, Project access will be adequate. Motorists entering and exiting the Projectsite will be able to do so without undue congestion. Furthermore, the anticipated queues at eachof the Project driveways are anticipated to be no more than one (I) vehicle during the AM andPM peak hours. To supplement the level of service analysis, a gap analysis has been completed along Harbor Boulevard as well as at the intersection of Figueroa Street at I st Street to determine if the existing gaps along the main arterial roadways are considered adequate to accommodate ingress and egress at the proposed Project driveways. The gap analysis indicates that there are more gaps than vehicles exiting, therefore, it can be concluded that both right-turning and left-turning vehicles will have adequate gaps along Harbor Boulevard and/or I st Street when exiting the Project site. •Sight Distance Evaluation -Sight lines for the southbound movements at the intersection ofFigueroa Street at l't Street, as well as at Project Driveway 1, along Harbor Boulevard, areexpected to be adequate. Sight lines at Project Driveways 2 and 3, along Figueroa Street, will beobstructed by vehicles parked on-street along Figueroa Street. As a result, it is recommended torestrict on-street parking along the Project frontage of Figueroa Street to help facilitate andenhance visibility for outbound vehicles. •Queuing Assessment -Adequate queue storage length is currently provided for the northboundleft-turn/"U-turn" lane located at the intersection of Harbor Boulevard and 5t h Street based on theanticipated maximum 95th percentile queue length under Existing, Existing plus Project, Year2028 Cumulative and Year 2028 Cumulative plus Project traffic conditions. Although the existing and future 95th percentile queues reported for the southbound left-turn/"U turn" and westbound left-turn movements at the intersection of Harbor Boulevard and 1 st Street exceed the existing storage lengths for the respective movements, these are existing queue storage deficiencies not caused by the Project. The 95th percentile queue lengths are LINSCOTT, LJ\w&GREENSPAN, engineers 49 LLG Ref. 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana I< ,-1700t:!1j 1737 -First H:1rbo1 \li>.ed l 'se. San\3 Ana·RcporH737 Fir;t H.ll l,or \(v.,:d.t:se. Sant:i .\ria Tr;iffic Study ID-23-2J doc Exhibit 9 conservative estimates of potential queues. It should be noted further that the Project-generated traffic that could be added to the southbound and westbound left-tum movements are nominal (i.e., southbound left-tum: 15 AM peak hour trips, 36 PM peak hour trips; westbound left-tum: 11 AM peak hour trips, 16 PM peak hour trips), corresponding to a maximum of one vehicle on a given cycle. Adequate queue storage length would be provided for the planned westbound right-tum pocket at the intersection of Harbor Boulevard and I st Street based on the anticipated maximum 95th percentile queue length under Existing plus Project, and Year 2028 Cumulative plus Project (during the AM peak hour only) traffic conditions. Although the future 95th percentile queue length of 232 feet during the PM peak hour would exceed the proposed pocket length of 213 feet, there is an additional 27 feet of queue storage on westbound I st Street between the end of the future right-tum pocket and Figueroa Street that would result in a total storage length of 240 feet, which could accommodate the forecasted queue length of 232 feet. Based on the considerations above, improvements are not recommended. ■Existing Plus Project Roadway Segment Evaluation -The roadway segment at Figueroa Street,between 5th Street and I st Street is forecast to continue to operate at an acceptable service levelon a daily basis with the addition of Project generated traffic to existing traffic and will not require improvements when compared to the LOS standards and thresholds specified in thisreport. •Year 2028 Cumulative Plus Project Roadway Segment Evaluation -The roadway segment atFigueroa Street, between 5th Street and I st Street is forecast to continue to operate at anacceptable service level on a daily basis with the addition of Project generated traffic in the Year2028 and will not require improvements when compared to the LOS standards and thresholdsspecified in this report. •VMT Screening Assessment -Based on the application of the City's screening criteria, andusing Appendices A, B, and C in the City's guidelines, it was determined that the Project islocated in a TP A and is in a low-VMT generating area; and is therefore screened out from furtherVMT project-level assessment because it can be presumed to have less-than-significant impactonVMT. ■Parking Analysis and PMP -The application of Specific Plan parking ratios to the variousProject components results in a total City Code requirement of 313 spaces. Comparing this Coderequirement against the proposed parking supply of 333 standard spaces results in a Code-based surplus of 20 spaces. Based on this, the Project's parking supply provisions would be adequatein meeting the City Code requirements for the Project. LINSCOTT, LAW & GREENSPAN, engineers 50 LLG Ref 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana K.,.t70011'.::H737 -F,rsc Harbor \11,�d u�. S:111u ,\na··R�port�HJ7 Fnst HarlXlr �lix�d-l'�-S:mu .\n� Traffi� StuJ; l0-:?.3-2J.doc Exhibit 9 Recommendations for PMP measures are provided in this study to ensure competing parking needs for all Project tenants, guests, and employees are adequately managed and controlled to facilitate parking efficiency. LINSCOTT, LAW & GREENSPAN, engineers 51 LLG Ref 2-23-4737-1 First Harbor Mixed-Use Development, Santa Ana \' -1700\�234737 -First Harbor \.��,:<I Cs.,;,. Santst AnJ\R�p,:m'47J7 First !-1:u·lxir M1�cd-l'.s.!. Santa .\n:i Tr�flic Study 10-2J-2J do� Exhibit 9 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 9 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) 5.2 AIR QUALITY 2-1 Applicants for new development projects within the Harbor Boulevard Mixed Use Transit Corridor Plan shall require the construction contractor to use equipment that meets the United States Environmental Protection Agency (EPA)-Certified emissions standards according to the following schedule. •From the end of 2011 to December 31, 2014, all project-relatedoff-road diesel-powered construction equipment greater than 50horsepower shall meet Tier 3 off-road emissions standards. Anyemissions control device used by the contractor shall achieveemissions reductions that are no less than what could beachieved by a Level 3 diesel emissions control strategy for asimilarly sized engine, as defined by CARB regulations. •After January 1, 2015, all off-road diesel-powered constructionequipment greater than 50 horsepower shall meet the Tier 4Final emission standards. Any emissions control device used bythe contractor shall achieve emissions reductions that are noless than what could be achieved by a Level 4 diesel emissionscontrol strategy for a similarly sized engine, as defined by CARBregulations. Prior to construction, the project engineer shall ensure that all demolition and grading plans clearly show the requirement for EPA Tier 3 or higher emissions standards for construction equipment over 50 horsepower. During construction, the construction contractor shall maintain a list of all operating equipment in use on the project site for verification by the Building Safety Division. The construction equipment list shall state the makes, models, and numbers of construction equipment onsite. Equipment shall properly service and maintain construction equipment in accordance with the manufacturer’s recommendations. Construction contractors shall also ensure that all nonessential idling of construction equipment is restricted to five minutes or less in compliance with California Air Project applicant Prior to grading permits; on-going monitoring during construction Planning and Building Agency, Building Safety Division Exhibit 10 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements Page 10 PlaceWorks Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) Resources Board’s Rule 2449. 2-2 Applicants for new development projects within the Harbor Boulevard Mixed Use Transit Corridor Plan shall require the construction contractor to prepare a dust control plan and implement the following measures during ground-disturbing activities in addition to the existing requirements for fugitive dust control under South Coast Air Quality Management District Rule 403 to further reduce PM10 and PM2.5 emissions. The Building Safety Division shall verify compliance that these measures have been implemented during normal construction site inspections. • Following all grading activities, the construction contractor shall reestablish ground cover on the construction site through seeding and watering. • During all construction activities, the construction contractor shall sweep streets with Rule 1186–compliant, PM10-efficient vacuum units on a daily basis if silt is carried over to adjacent public thoroughfares or occurs as a result of hauling. • During all construction activities, the construction contractor shall maintain a minimum 24-inch freeboard on trucks hauling dirt, sand, soil, or other loose materials and tarp materials with a fabric cover or other cover that achieves the same amount of protection. • During all construction activities, the construction contractor shall water exposed ground surfaces and disturbed areas a minimum of every three hours on the construction site and a minimum of three times per day. • During all construction activities, the construction contractor shall limit onsite vehicle speeds on unpaved roads to no more than 15 miles per hour. Project applicant Prior to grading permits; on-going monitoring during construction Planning and Building Agency, Building Safety Division 2-3 Applicants for new development projects within the Harbor Boulevard Mixed Use Transit Corridor Plan shall require the construction contractor to use coatings and solvents with a volatile organic Project applicant Prior to building permits; on-going monitoring during construction Planning and Building Agency, Building Safety Division Exhibit 10 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 11 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) compound (VOC) content lower than required under Rule 1113 (i.e., super compliant paints). All architectural coatings shall be applied either by (1) using a high-volume, low-pressure spray method operated at an air pressure between 0.1 and 10 pounds per square inch gauge to achieve a 65 percent application efficiency; or (2) manual application using a paintbrush, hand-roller, trowel, spatula, dauber, rag, or sponge, to achieve a 100 percent applicant efficiency. The construction contractor shall also use precoated/natural colored building materials, where feasible. Use of low-VOC paints and spray method shall be included as a note on architectural building plans and verified by the Building Safety Division during construction. 2-4 Applicants of residential developments which are designed to include shared community barbeques shall only install electric powered barbeque units. These units shall be specified on site and building plans and shall be verified by the Building Safety Division prior to issuance of a Certificate of Occupancy. Project applicant Prior to issuance of certificate of occupancy Planning and Building Agency, Building Safety Division 2-5 Applicant-provided appliances shall be Energy Star appliances (dishwashers, refrigerators, clothes washers, and dryers). Installation of Energy Star appliances shall be verified by the Building Safety Division during plan check. Project applicant Prior to issuance of certificate of occupancy Planning and Building Agency, Building Safety Division 2-6 Applicants of residential developments which include garage and/or car port parking shall ensure that garage and/or car port parking are electrically wired to accommodate a Level 2 (240 volt) electric vehicle charging outlet per dwelling unit. The location of the electrical outlets shall be specified on building plans and proper installation shall be verified by the Building Safety Division prior to issuance of a Certificate of Occupancy. Project applicant Prior to issuance of certificate of occupancy Planning and Building Agency, Building Safety Division 2-7 Applicants of retail, commercial, office, and other non-residential development shall provide Level 2 vehicle charging stations for public use and where feasible, coordinate with the City of Santa Ana to install Level 3 (480 volt or higher) charging stations. The location of the charging station(s) shall be specified on site and building plans Project applicant Prior to issuance of certificate of occupancy Planning and Building Agency, Building Safety Division Exhibit 10 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements Page 12 PlaceWorks Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) and proper installation shall be verified by the Building Safety Division prior to issuance of a Certificate of Occupancy. 2-8 Applicants for non-residential projects within the Harbor Boulevard Mixed Use Transit Corridor Plan, that employ 20 or more people—which is equivalent to 16,000 square feet of retail space or 10,000 square feet of office space—shall implement an employee commute trip reduction (CTR) program. The CTR program shall identify alternative modes of transportation to the project, including transit schedules, bike and pedestrian routes, and carpool/vanpool availability. Information regarding these programs shall be readily available to employees and clients. The project applicant or designee shall consider the following incentives for commuters as part of the CTR program: • Rideshare matching assistance through OCTA • Subsidized public transit passes • Vanpool assistance • Car or bike-sharing program • Bicycle end-trip support facilities such as bike storage or lockers. Project applicant Prior to issuance of certificate of occupancy Planning and Building Agency, Planning Division 2-9 Applicants of commercial, office, retail, and other non-residential development within the specific plan area shall provide the following features to reduce project-related mobile-source air pollutant emissions: • Preferential parking for carpools and vanpools. • Preferential parking for alternative-fuel vehicles (e.g., compressed natural gas or hydrogen). • Secure bicycle parking and storage facilities for visitors. • Commuter information boards identifying bicycle paths and public transit routes and schedules. Project applicant Prior to issuance of building permit Planning and Building Agency, Planning Division 2-10 Applicants for residential or residential mixed-use projects within: 1) 1,000 feet from the truck bays of an existing distribution centers that accommodate more than 100 trucks per day, more than 40 trucks with Project applicant Prepare HRA prior to approval of any future discretionary residential or Planning and Building Agency, Building Safety Division, Zoning Exhibit 10 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 13 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) operating transport refrigeration units, or where transport refrigeration unit operations exceed 300 hours per week; or 2) 1,000 feet of an SCAQMD permitted facility, or an industrial facility which emits toxic air contaminants shall submit a health risk assessment (HRA) prepared in accordance with policies and procedures of the state Office of Environmental Health Hazard Assessment (OEHHA) and the South Coast Air Quality Management District (SCAQMD). The HRA shall be submitted to the Zoning Administrator prior to approval of any future discretionary residential or residential mixed-use project. If the HRA shows that the incremental cancer risk exceeds one in one hundred thousand (1.0E-05), PM concentrations would exceed 2.5 μg/m3, or the appropriate noncancer hazard index exceeds 1.0, the HRA shall identify the level of high-efficiency Minimum Efficiency Reporting Value (MERV) filter required to reduce indoor air concentrations of pollutants to achieve the cancer and/or noncancer threshold. The Applicant shall be required to install high efficiency MERV filters in the intake of residential ventilation systems, consistent with the recommendations of the HRA. Heating, air conditioning and ventilation (HVAC) systems shall be installed with a fan unit power designed to force air through the MERV filter. To ensure long-term maintenance and replacement of the MERV filters in the individual units, the following shall occur: • Developer, sale, and/or rental representative shall provide notification to all affected tenants/residents of the potential health risk for affected units. • For rental units, the owner/property manager shall maintain and replace MERV filters in accordance with the manufacture’s recommendations. The property owner shall inform renters of increased risk of exposure to diesel particulates when windows are open. • For residential owned units, the Homeowner’s Association (HOA) shall incorporate requirements for long-term maintenance residential mixed-use project; Installation of MERV filter requirements and maintenance prior to issuance of building permits Administrator Exhibit 10 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements Page 14 PlaceWorks Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) in the Covenant Conditions and Restrictions and inform homeowners of their responsibility to maintain the MERV filter in accordance with the manufacturer’s recommendations. The HOA shall inform homeowners of increased risk of exposure to diesel particulates when windows are open. 5.3 CULTURAL RESOURCES 3-1 Prior to the issuance of grading permits, and for any subsequent permit involving excavation to increased depth, the project applicant for each development or redevelopment project considered for approval pursuant to the Harbor Boulevard Mixed Use Transit Corridor Plan shall provide letters to the City of Santa Ana from a qualified archaeologist and paleontologist (for excavations six feet below ground surface and deeper) who meet the Secretary of the Interior’s Professional Qualifications Standards. The letters shall state that the project applicant has retained these individuals, and that the consultant(s) will be on call during all grading and other significant ground-disturbing activities. In the event archeological or paleontological resources are discovered during ground-disturbing activities, the professional archeological or paleontological monitor shall have the authority to halt any activities adversely impacting potentially significant cultural resources until they can be formally evaluated. Suspension of ground disturbances in the vicinity of the discoveries shall not be lifted until the archaeological or paleontological monitor, in coordination with the construction contractor, has evaluated discoveries to assess whether they are significant cultural resources, pursuant to the California Environmental Quality Act (CEQA). If significance criteria are met, then the project shall be required to perform data recovery, professional identification, radiocarbon dates as applicable, and other special studies; they shall be offered for curation or preservation to a repository with a retrievable collection system and an educational and research interest in the materials, such as the Los Angeles County Museum of Natural History or California State University, Fullerton, or other local museum or repository. If no museum or repository is willing to accept the Project applicant Prior to issuance of grading permit Planning and Building Agency, Planning Division Exhibit 10 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 15 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) resource, the resource shall be considered the property of the City, and may be stored, disposed of, transferred, exchanged, or otherwise handled by the City at its discretion. 5.6 HAZARDS AND HAZARDOUS MATERIALS 6-1 Prior to the issuance of demolition permits for any buildings or structures that would be demolished in conjunction with individual development projects that would be accommodated by the Harbor Boulevard Mixed Use Transit Corridor, the project applicant shall conduct the following inspections and assessments for all buildings and structures onsite and shall provide the City of Santa Ana’s Planning and Building Agency with a copy of the report of each investigation or assessment. • The project applicant shall retain a certified lead inspector/assessor to inspect buildings and structures onsite for lead-based paint (LBP). The inspector/assessor’s report shall include requirements for abatement, containment, and disposal of LBP, if encountered, in accordance with the State of California Occupational Safety & Health Administration Rule 29 CFR Part 1926. • The project applicant shall retain a licensed or certified asbestos consultant to inspect buildings and structures onsite for asbestos-containing materials (ACM). The consultant’s report shall include requirements for abatement, containment, and disposal of ACM, if encountered, in accordance with the South Coast Air Quality Management District’s Rule 1403. Project applicant Prior to issuance of demolition permit Planning and Building Agency, Building Safety Division 6-2 Prior to the issuance of grading permits for new development within the Harbor Boulevard Mixed Use Transit Corridor, the project applicant shall submit a Phase I Environmental Site Assessment (ESA) to identify environmental conditions and determine whether contamination is present. The Phase I ESA shall be prepared by a Registered Professional Engineer and in accordance with the American Society for Testing and Materials (ASTM) Standard E Project applicant Submit Phase I ESA prior to issuance of grading permit; Submit remediation documentation prior to issuance of building permit, if needed Building Official Exhibit 10 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements Page 16 PlaceWorks Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) 1527.05, Standard Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process. If recognized environmental conditions related to soils are identified in the Phase I ESA, the project applicant shall perform soil sampling as a part of a Phase II ESA. If contamination is found at significant levels, the project applicant shall remediate all contaminated soils in accordance with state and local agency requirements (DTSC, RWQCB, Orange County Fire Authority, etc.). All contaminated soils and/or material encountered shall be disposed of at a regulated site and in accordance with applicable laws and regulations prior to the completion of grading. Prior to the issuance of building permits, a report documenting the completion, results, and any follow-up remediation on the recommendations, if any, shall be provided to the Building Official and the City of Santa Ana’s Planning and Building Agency evidencing that all site remediation activities have been completed. 5.7 HYDROLOGY AND WATER QUALITY 7-1 Prior to issuance of grading permits for future development projects in the Harbor Corridor Plan, applicants shall submit site-specific hydrology and hydraulic Studies to the Public Works Agency for review and approval. If existing facilities are not adequate to handle runoff generated by the proposed development, then the applicant shall construct storm drain improvements. Storm drain upgrades shall be implemented prior to issuance of occupancy permits. Project applicant Prior to issuance of grading permit Public Works Agency 7-2 During the design of individual projects, applicants shall minimize impervious area by incorporating landscaped areas over substantial portions of a proposed project area. Furthermore, impervious areas shall be directly connected to landscaped areas or bioretention facilities to promote filtration and infiltration of stormwater. The applicant must comply with the latest Orange County Model Water Quality Management Plan (WQMP). Project applicant Prior to issuance of grading permit Public Works Agency 7-3 Notice of Intent (NOI). Prior to the issuance of a grading permit for Project applicant Prior to issuance of grading Public Works Agency; City Exhibit 10 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 17 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) construction sites with a disturbed area of one or more acres, the project applicant shall provide the City Engineer with evidence that a NOI has been filed with the State Water Resources Control Board. Such evidence shall consist of a copy of the NOI stamped by the State Water Resources Control Board or Regional Water Quality Control Board, or a letter from either agency stating that the NOI has been filed. permit Engineer 7-4 Storm Water Pollution Prevention Plan (SWPPP). Prior to the issuance of grading permits for construction sites with a disturbed area of one or more acres, the project applicant shall prepare a SWPPP that will: • Require implementation of best management practices (BMPs) designed with a goal of preventing a net increase in sediment load in stormwater discharges relative to preconstruction levels; • During the construction period, prohibit discharges of stormwater or non-storm water at levels which would cause or contribute to an exceedance of applicable water quality standards contained in the Basin Plan; • Discuss in detail the BMPs planned for the project related to control of sediment and erosion, nonsediment pollutants, and potential pollutants in non-storm water discharges; • Describe post-construction BMPs for the project; • Explain the maintenance program for the project’s BMPs; • During construction, require reporting of violations to the Regional Board; • List the parties responsible for SWPPP implementation and BMP maintenance during and after grading. The project proponent shall implement the SWPPP and will modify the SWPPP as directed by the Storm Water Permit. Project applicant Prior to issuance of grading permit Public Works Agency; City Engineer 7-5 Water Quality Management Plan (WQMP). Prior to the issuance of precise grading permits, project-specific WQMPs shall be submitted for review and approved by the Public Works Agency. The WQMP Project applicant Prior to issuance of precise grading permits Property Owner Exhibit 10 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements Page 18 PlaceWorks Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) shall identify the best management practices (BMPs) that will be used on the site to control predictable pollutant runoff. More specifically, the WQMP shall: • Describe the routine and special post-construction BMPs to be used at the proposed development site (including both structural and non-structural measures); • Describe responsibility for the initial implementation and long-term maintenance of the BMPs; • Provide narrative with the graphic materials as necessary to specify the locations of the structural BMPs; • Certify that the project applicant will seek to have the WQMP carried out by all future successors or assigns to the property. • The applicant must comply with the latest Orange County Model Water Quality Management Plan (WQMP). 7-6 Prior to the issuance of precise grading permit for any lot or parcel wholly or partially located within the 100-year floodplain, the applicant shall furnish to the Building Official documentation required by FEMA for approval of the Conditional Letter of Map Revision/Letter of Map Revision (CLOMR/LOMR) process. The FEMA for revision to the FIRM and Flood Insurance Study (FIS). The applicant shall pay all preliminary and subsequent fees as required by FEMA. Project applicant Prior to issuance of precise grading permit Building Official 5.9 NOISE 9-1 Prior to issuance of a building permit, applicants for new residential development in the Harbor Corridor Plan shall submit an acoustic report prepared to the satisfaction of the Building Official or their designee to ensure that noise levels at outdoor living areas such as private yards, balconies, and park picnic areas shall not exceed 65 dBA CNEL, and all residential habitable rooms would meet the 45 dBA CNEL interior noise standard. These noise studies would need to be submitted after the precise grading and architectural plans are prepared, but prior to issuance of building permits. The required Project applicant Prior to issuance of building permit Planning and Building Agency, Building Safety Division Exhibit 10 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 19 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) exterior noise reduction can be accomplished with sound walls or berms, or by site plan/building layout design. The required interior noise reduction can be accomplished with enhanced construction design or materials such as upgraded dual-glazed windows and/or upgraded exterior wall assemblies. These features shall be shown on all building plans and incorporated into construction of the project. City inspectors shall verify compliance of the building with the acoustic report’s recommendations prior to issuance of a Certificate of Occupancy. 9-2 Prior to issuance of a building permit, applicants for new commercial, office, or retail developments in the Harbor Corridor Plan shall submit an acoustic report prepared to the satisfaction of the Zoning Administrator and Building Official or their designee to ensure that the operation of stationary noise sources (i.e., HVAC units, truck deliveries) would not cause a noise increase of more than 5 dBA over the ambient noise levels at any adjacent property. These noise studies would need to be submitted after the precise grading and architectural plans are prepared, but prior to issuance of building permits. This requirement can be accomplished with selection of quieter equipment, judicious site layouts and equipment positioning, and/or equipment enclosures, sound screening, or parapet walls. These features shall be shown on all building plans and incorporated into the construction of the project. City inspectors shall verify compliance of the building with the acoustic report’s recommendations prior to issuance of a Certificate of Occupancy. Project applicant Prior to issuance of building permit; prior to issuance of certificate of occupancy Planning and Building Agency, Zoning Administrator and Building Official or designee 9-3 Prior to issuance of a building permit, applicants for projects within the Harbor Corridor Plan that involve high-vibration construction activities, such as pile driving or vibratory rolling/compacting, shall be evaluated for potential vibration impacts to nearby sensitive receptors. The project developer shall submit a vibration report prepared to the satisfaction of the City of Santa Ana Building Official or their designee to determine if the use of pile driving and/or vibratory rolling/compacting equipment would exceed the Federal Transit Project applicant Prior to issuance of building permit Planning and Building Agency, Building Official or designee Exhibit 10 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements Page 20 PlaceWorks Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) Administration’s (FTA’s) vibration-annoyance criteria of 78 VdB during the daytime or FTA’s vibration-induced architectural damage PPV criteria of 0.2 inches/second for wood-framed structures or 0.5 inches/second for reinforced masonry buildings. The construction contractor shall require the use of lower-vibration-producing equipment and techniques. Examples of lower-vibration equipment and techniques would include avoiding the use of vibratory rollers near sensitive areas and/or the use of drilled piles, sonic pile driving, or vibratory pile driving (as opposed to impact pile driving). 9-4 Prior to issuance of grading permits, the project applicant shall ensure the following notes are included on the grading plan cover sheet, and the construction contractor shall comply with these measures during the duration of all construction activities. • Properly maintain and tune all construction equipment to minimize noise. • Fit all equipment with properly operating mufflers, air intake silencers, and engine shrouds, no less effective than as originally equipped by the manufacturer, to minimize noise emissions. • Locate all stationary noise sources (e.g., generators, compressors, staging areas) as far from noise-sensitive receptors as possible. Material delivery, soil haul trucks, and equipment servicing shall be restricted to the hours between 7:00 AM and 8:00 PM Mondays through Saturdays, and not at all on Sundays or federal holidays. Project applicant Prior to issuance of grading permit Planning and Building Agency, Planning Division 9-5 Prior to the issuance of grading permits, each project applicant within the project area shall prepare a construction management plan that shall be approved by the City of Santa Ana Public Works. The construction management plan shall: • Establish truck haul routes on the appropriate transportation facilities. Truck routes that avoid congested streets and sensitive land uses shall be considered. Project applicant Prior to issuance of grading permit Public Works Agency Exhibit 10 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 21 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) • Provide Traffic Control Plans (for detours and temporary road closures) that meet the minimum City criteria. Traffic control plans shall determine if dedicated turn lanes for movement of construction truck and equipment on- and offsite are available. • Minimize offsite road closures during the peak hours. • Keep all construction-related traffic onsite at all times. • Provide temporary traffic controls, such as a flag person, during all phases of construction to maintain smooth traffic flow. 5.13 TRANSPORTATION AND CIRCULATION 13-1 Prior to the issuance of building permits, the project applicant shall evaluate the potential for any neighborhood cut through traffic. Neighborhood cut through traffic shall be minimized through implementation of traffic calming measures as approved by the Public Works Agency. Project applicant Prior to the issuance of building permit Public Works Agency 13-2 The City of Santa Ana shall implement a program for traffic improvements in the Harbor Corridor Plan. The program shall prescribe the method of participation in the mitigation program by individual projects and guide the timely implementation of mitigation measures. The program shall include the following elements: • A funding and improvement program should be established to identify financial resources adequate to construct all identified mitigation measures in a timely basis. • All properties that redevelop within the Harbor Corridor Plan should participate in the program on a fair share per new development trip basis. The fair share shall be based upon the total cost of all identified mitigation measures (see Mitigation Measure 13-3), divided by the peak hour trip generation increase forecast. This rate per peak hour trip should be imposed upon the incremental traffic growth for any new development within the Harbor Corridor Plan. • The project shall raise fund from full development of the Harbor City of Santa Ana On-going monitoring Public Works Agency Exhibit 10 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements Page 22 PlaceWorks Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) Corridor Plan to fund all identified mitigation measures. • The project shall monitor phasing development of the Harbor Corridor Plan and defer or eliminate improvements if the densities permitted in the Harbor Corridor Plan are not occurring. • Program phasing shall be monitored through preparation of specific project traffic studies for any project that is expected to include more than 100 dwelling units or 100,000 sf of non-residential development. Traffic impact studies should use traffic generation rates that are deemed to be most appropriate for the actual development proposed. • The City may elect to implement appropriate mitigation measures as a condition of approval of the proposed developments, where appropriate. All or part of the costs of these improvements may be considered to be a negotiated credit toward the program, however the program must be administered in a manner that assures that it can fund necessary improvements to maintain adequate level of service at all intersections within the study. If funding of priority improvements cannot be assured, credit for construction of lower priority improvements may not be assured or may be postponed until more program funds are available. 13-3 Prior to the issuance of building permits, the project applicant shall participate in the program for traffic improvements in the Harbor Corridor Plan per MM 13-2. The traffic improvement program includes the following improvements: • Intersection #26: Fairview Street and 17th Street (Year 2035) o Improvements are to add a northbound through lane. • Intersection #27: Fairview Street and 1st Street (Year 2035) o Improvements are to add a southbound right-turn lane. Project applicant Prior to issuance of building permit Public Works Agency 5.14 UTILITIES AND SERVICE SYSTEMS 7-1 Mitigation Measure 7-1 applies. See Hydrology and Water Quality section, above. Exhibit 10 HARBOR BOULEVARD MIXED USE TRANSIT CORRIDOR PLAN MMRP CITY OF SANTA ANA 3. Mitigation Monitoring Requirements August 2014 Page 23 Table 3-1 Mitigation Monitoring Requirements Mitigation Measure Responsibility for Implementation Timing Responsibility for Monitoring Monitor (Signature Required) (Date of Compliance) 14-1 Prior to the first building permit pursuant to the proposed project, the City of Santa Ana shall prepare a “Nexus” Study that will serve as the basis for requiring development impact fees under AB 1600 legislation, as codified by California Code Government Section 66000 et seq. The established procedures under AB 1600 require that a “reasonable relationship” or nexus exist between the water and sewer infrastructure improvements and facilities required to mitigate the sewer impacts of new development pursuant to the proposed project. The sewer segment improvements shown on Table 5.14-11 of the DEIR are necessary to mitigate project impacts and shall be included, among other improvements, in the AB 1600 nexus study. City of Santa Ana Prior to issuance of first building permit Public Works Agency 14-2 Prior to the issuance of the first building permit pursuant to the proposed project, the City of Santa Ana shall prepare a Development Fee program pursuant to the AB 1600 Nexus Study identified in Mitigation Measure 14-1, above. The Development Fee program would fund the Harbor Corridor Plan area-wide water and sewer infrastructure improvements. The fee program shall stipulate that fees are assessed when there is new construction or when there is an increase in square footage within an existing building or the conversion of existing square footage to a more intensive use. Fees are calculated by multiplying the proposed square footage or dwelling unit by the rate identified. The fees are included with any other applicable fees payable at the time the building permit is issued. The City will use the development fees to fund construction (or to recoup fees advanced to fund construction) of the infrastructure improvements identified in Mitigation Measure 14-1. City of Santa Ana Prior to issuance of first building permit Public Works Agency 14-3 Prior to the issuance of a grading permit, the project applicant shall prepare water and sewer studies and identify the sizing and location of backbone facilities necessary to serve the proposed project, in accordance with City standards. The water and sewer plans shall be submitted to the City’s Public Works Agency for review and approval. Design of facilities that serve the project shall be sufficient to meet the projected service demands. Project applicant Prior to issuance of a grading permit Public Works Agency Exhibit 10 Exhibit 11 O R A N G E C O U N T Y R E P O R T E R ~SINCE 1921~ Mailing Address : 600 W SANTA ANA BLVD STE 812, SANTA ANA, CA 92701 Telephone (714) 543-2027 / Fax (714) 542-6841 Visit us @ www.LegalAdstore.com NUVIA OCAMPO CITY OF SANTA ANA/PLANNING & BUILDING AGENCY 20 CIVIC CENTER PLAZA 2ND FLR SANTA ANA, CA 92702 OR# 3791473 NOTICE OF PUBLIC HEARINGBEFORE THE SANTA ANA PLANNINGCOMMISSION 647-5481 or by email atJGuevara@santa-ana.org.Note: If you challenge the decision on theabove matter, you may be limited toraising only those issues you or someoneelse raised at the public hearingdescribed in this notice, or in writtencorrespondence delivered to the PlanningCommission or City Council of the City ofSanta Ana at, or prior to, the publichearing. The City of Santa Ana encourages thepublic to participate in the decision-making process. We encourage you tocontact us prior to the Public Hearing ifyou have any questions.COPY OF NOTICE Planning Commission Action: ThePlanning Commission will hold a PublicHearing to receive public testimony, andwill take action on the item describedbelow. Decision on this matter will be finalunless appealed pursuant to Article V ofChapter 41 of the Santa Ana MunicipalCode within 10 calendar days of thedecision by any interested party or group.Project Location: 101 North HarborBoulevard located within the Transit NodeSouth (TNS) district of the Harbor Mixed-Use Transit Corridor Specific Plan (SP-2).Project Applicant: Charles Minyard withPrimior, Inc. and representing Harbor andFirst, LLC. (Applicant & Property Owner) Si tiene preguntas en español, favor dellamar a Nuvia Ocampo (714) 667-2732.N ? u c ? n liên l ? c b ? ng ti ? ng Vi ?t, xin ?i ? n tho ? i cho Tony Lai s ?(714) 565-2627.Notice Type:GPN GOVT PUBLIC NOTICE 3/15/24Ad Description OR-3791473# 1st and Harbor Blvd To the right is a copy of the notice you sent to us for publication in the ORANGE COUNTY REPORTER. Thank you for using our newspaper. Please read this notice carefully and call us with any corrections. The Proof of Publication will be filed with the County Clerk, if required, and mailed to you after the last date below. Publication date(s) for this notice is (are): Proposed Project:Applicant isrequesting approval of Site Plan Review(SPR) No. 2024-01 and Tentative TractMap (TTM) No. 2024-01 to facilitate theconstruction of a mixed-use developmentknown as First Harbor Mixed-UseDevelopment. Applicant is proposing todevelop an existing vacant lot with a nine-story mixed-use building consisting of03/15/2024 15,182 square feet of leasablecommercial space, 1,845 square feet ofleasing office space, 181 for-saleresidential condominium units (including10 affordable units), 339 parking spaces,and 40,853 square feet of open spaceand amenities.Environmental Impact: Pursuant to theCalifornia Environment Quality Act(CEQA0, the project is within the scope ofthe 2014 Harbor Boulevard Mixed-UseTransit Corridor Plan EnvironmentalImpact Report (EIR) (SCH No. 2013-061027). The charge(s) for this order is as follows. An invoice will be sent after the last date of publication. If you prepaid this order in full, you will not receive an invoice. Meeting Details: This matter will beheard on Monday, March 25, 2024 at5:30 p.m. in the City Council Chambers,22 Civic Center Plaza, Santa Ana, CA92701. Members of the public mayattend this meeting in person or joinvia Zoom. For the most up-to-dateinformation on how to participate virtuallyinthismeeting,please visitDaily Journal Corporation https://www.santa-ana.org/planning-and-building-meeting-participation/.Written Comments:If you are unable toparticipate in the meeting, you may sendwrittenPBAeComments@santa-ana.org(reference the Agenda Item Serving your legal advertising needs throughout California. comments by e-mail toORANGE COUNTY REPORTER, SANTA ANA BUSINESS JOURNAL, RIVERSIDE (714) 543-2027 (951) 784-0111 (213) 229-5300 (213) 229-5300 (800) 640-4829 (408) 287-4866 (916) 444-2355 (619) 232-3486 (510) 272-4747 #in thesubject line) or by mail to Nuvia Ocampo,Recording Secretary, City of Santa Ana,20 Civic Center Plaza – M20, Santa Ana,CA 92701. Deadline to submit writtencomments is 3:30 p.m. on the day of themeeting. Comments received after thedeadline may not be distributed to theCommission but will be made part of therecord. DAILY COMMERCE, LOS ANGELES LOS ANGELES DAILY JOURNAL, LOS ANGELES SAN FRANCISCO DAILY JOURNAL, SAN FRANCISCO SAN JOSE POST-RECORD, SAN JOSE THE DAILY RECORDER, SACRAMENTO THE DAILY TRANSCRIPT, SAN DIEGO THE INTER-CITY EXPRESS, OAKLAND Where To Get More Information:Additional details regarding the proposedaction(s), including the full text of thediscretionary item, may be found on theCity website 72 hours prior to the publichearingathttps://santa-ana.primegov.com/public/portal.Who To Contact For Questions: Shouldyou have any project questions, pleasecontact case planner Jerry Guevara withthe Planning Division by phone at (714) !A000006708726! Exhibit 11 CITY OF SANTA ANA Planning and Building Agency20 Civic Center Plaza ● P.O. Box 1988 Santa Ana, California 92702 www.santa-ana.org/pba NOTICE OF PUBLIC HEARING BEFORE THE SANTA ANA PLANNING COMMISSION The City of Santa Ana encourages the public to participate in the decision-making process. This notice is being sent to those who live or own property within 1000 feet of the project site or who have expressed an interest in the proposed action. We encourage you to contact us prior to the Public Hearing if you have any questions. Planning Commission Action: The Planning Commission will hold a Public Hearing to receive public testimony, and will take action on the item described below. Decision on this matter will be final unless appealed within 10 calendar days of the decision by any interested party or group. Project Location:101 North Harbor Boulevard located within the Transit Node South (TNS) district of the Harbor Mixed-Use Transit Corridor Specific Plan (SP-2). Project Applicant:Charles Minyard with Primior, Inc. and representing Harbor and First, LLC. (Applicant & Property Owner) Proposed Project: Applicant is requesting approval of Site Plan Review (SPR) No. 2024-01 and Tentative Tract Map (TTM) No. 2024-01 to facilitate the construction of a mixed-use development known as First Harbor Mixed-Use Development. Applicant is proposing to develop an existing vacant lot with a nine- story mixed-use building consisting of 15,182 square feet of leasable commercial space, 1,845 square feet of leasing office space, 181 for-sale residential condominium units (including 10 affordable units), 339 parking spaces, and 40,853 square feet of open space and amenities. Environmental Impact: Pursuant to the California Environment Quality Act (CEQA0, the project is within the scope of the 2014 Harbor Boulevard Mixed-Use Transit Corridor Plan Environmental Impact Report (EIR) (SCH No. 2013-061027). Meeting Details: This matter will be heard on Monday, March 25, 2024 at 5:30 p.m. in the City Council Chambers, 22 Civic Center Plaza, Santa Ana, CA 92701. Members of the public may attend this meeting in person or join via Zoom. For the most up-to-date information on how to participate virtually in this meeting, please visit https://www.santa-ana.org/planning-and-building-meeting-participation/. Written Comments: If you are unable to participate in the meeting, you may send written comments by e- mail to PBAeComments@santa-ana.org (reference the Agenda Item # in the subject line) or by mail to Nuvia Ocampo, Recording Secretary, City of Santa Ana, 20 Civic Center Plaza – M20, Santa Ana, CA 92701. Deadline to submit written comments is 3:30 p.m. on the day of the meeting. Comments received after the deadline may not be distributed to the Commission but will be made part of the record. Where To Get More Information: Additional details regarding the proposed action(s), including the full text of the discretionary item, may be found on the City website 72 hours prior to the public hearing at https://santa-ana.primegov.com/public/portal. Exhibit 11 Who To Contact For Questions: Should you have any project questions, please contact case planner Jerry Guevara with the Planning Division by phone at (714) 647-5481 or by email at JGuevara@santa- ana.org. Note: If you challenge the decision on the above matter, you may be limited to raising only those issues you or someone else raised at the public hearing described in this notice, or in written correspondence delivered to the Planning Commission or City Council of the City of Santa Ana at, or prior to, the public hearing. Si tiene preguntas en español, favor de llamar a Nuvia Ocampo (714) 667-2732. Nếu cần liên lạc bằng tiếng Việt, xin điện thoại cho Tony Lai số (714) 565-2627. 1000’ RADIUS NOTIFICATION MAP Exhibit 11