Laserfiche WebLink
15. Doors to all work areas, Including stairwells and mechanical and electrical closets, will remain closed at all time. Propping doors open is <br />expressly prohibited. <br />16. All Contractor and subcontractor personnel, materials, tools and equipment are to enter and exit the Building through the service elevator <br />only, Owner may at any time initiate a check in/check out system, or a badge system, for all people and material in the Building and the <br />Contractor will agree to cooperate with any such system. <br />17. Before ordering material or doing work which is dependent upon proper size or installation, the Contractor shall field verify all dimensions <br />for accessibility with building conditions, and shall be responsible for saute. <br />18. Contractor shall not permitted Bay identifying signage or advertising within the Project or Building. <br />19. During construction, Contractor shall maintain supervisory personnel on the site at all times. Such personnel shall be fully authorized to <br />coordinate, respond for and authorize Contractor's work as necessary so as to enable all work to proceed in a timely and well -ordered <br />fashion. Should Contractor perform work which would cause or require Owner to provide personnel to be present or otherwise perform <br />any work, Contractor shall reimburse Owner for the expense of such personnel. <br />20• Contractor shall be responsible for the protection of its work and the area adjacent to his work. <br />21. Contractor will ensure that all stairwells, mechanical rooms, electrical and telephone closets, etc, accessed by Contractor or subcontractors <br />in conjunction with Contractor's work, will be cleaned and tree of debris nightly. <br />22. Public areas adjacent to premises where Contractor's work is being performed shall remain free of debris and materials at all times. <br />23, Contractor shall be responsible for all his actions on site as well as those of its subcontractors, and shall indemnify, defend and hold <br />harmless the Owner mid the other Owner Patties from and against any and all claims, losses, or damages, threatened or incurred, arising <br />from the actions or omissions of Contractor or its subcontractors. <br />24• If keys are required by contractors, they must be checked out from the Property Management Office. No key will be distributed If proper <br />identification is not provided. <br />25. No cutting or patching of Owner's premises or installations, or those of any Building occupant, shall be permitted without the prior written <br />consent of Owner. Request for permission to do cutting shall include explicit details and description of work and shall not under any <br />circumstances diminish the structural integrity of tie Building or die Integrity of any of components m• systems. The work is to be done <br />only with the explicit written permission of the Property Manager, and only on sit "Off -Hours" basis, Such work is to be done only under <br />the direct supervision of a competent member of the Contractor staff, Any such area is to be promptly repaired and returned to a fully <br />functioning, complete, and clean condition. <br />26. All work is to be done to a minimum standard of quality as required by the Base Building Drawings and Specifications (to be made <br />available by Owner upon request). It is the responsibility of the Contractor to be filly knowledgeable of the Base Building Drawings and <br />Specifications. <br />27, All Life Safety Systems for the Building are to be maintained, and all of the Tenant's work is to be properly interfaced with and connected <br />to the Base Building systems as required by Laws, or by Building operation. All work is to be done in such a way as to protect all Base <br />Building operations and warranties. Any required disconnection of life safety devices should be "foreseer" and tine Property Management <br />Office must be notified at least 24 hoes in advance. Costs for false fire alarms due to contractors' or subcontractors' negligence will be <br />billed to and paid by the Conunctor. All life -safety systems testing must he performed on an "after-hours" basis and coordinated with the <br />Building Manager. <br />28, When work is performed by Contractor or subcontractor, charges will apply for additional services performed by Owner which may <br />include, but are not necessarily limited to tie following: <br />A - overtime or after-liours elevator usage <br />nlllity usage fbr construction activities beyond standard power and water used in connection with general office uses <br />extra and continuous dean -up of elevators and public spaces as required due to construction activity; Contractor to provide tie <br />usual protection of existing improvements, and exercise care and good sense <br />extended or after-hours use of the loading dock <br />29. In addition to cleaning roquiremenls described above, Contractor shall, in preparation for substantial completion or occupancy of the <br />project by Tenant, pert'omh final cleaning orcoulructo's Work. <br />30, When Contractor takes over an area front the Owner, before commencing work Contractor shall ascertain that the area is in a sale and <br />sanitary condition, and maintain the area as necessary (at its sole cost and expense) in It sale and sanitary condition and to a standard <br />alerting all applicable laws and regulations. <br />31 • Owner requires Job progress meetings, -file Contractor will attend with a representative authorized to speak and act oil the Contractor's <br />behalf. Additionally. the Contractor shall notify the Owner orscheduled job progress meetings. <br />,YlI/ FVCirtie Center Or—CFry nJ'Smrrn.4an Lrna'r -5- Exhibit D <br />