My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
75D - PH - 2525 N MAIN
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2019
>
11/19/2019
>
75D - PH - 2525 N MAIN
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2019 7:54:38 PM
Creation date
11/14/2019 5:55:43 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Planning & Building
Item #
75D
Date
11/19/2019
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1376
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table N-3: Project Operational Noise Level Compliance <br />Receiver <br />Location <br />Land <br />Use <br />Noise Level at Receiver Locations dBA <br />Threshold <br />Exceeded? <br />Lso <br />30 mins <br />L2s <br />15 mins <br />Ls <br />5 mins <br />L2 <br />1 min <br />L.a, <br />e1 min) <br />Daytime <br />Residential <br />Standards <br />55 <br />60 <br />65 <br />70 <br />75 <br />Nighttime <br />50 <br />55 <br />60 <br />65 <br />70 <br />R1 <br />Residential <br />37.9 <br />40.7 <br />44.8 <br />48.7 <br />51.8 <br />No <br />R2 <br />Residential <br />43.2 <br />45.4 <br />49.0 <br />52.8 <br />58.6 <br />No <br />R3 <br />Residential <br />46.3 <br />48.6 <br />51.7 <br />54.9 <br />59.9 <br />No <br />R4 <br />Residential <br />46.9 <br />49.1 <br />52.1 <br />55.3 <br />59.9 <br />No <br />R5 <br />Residential <br />36.7 <br />39.4 <br />45.7 <br />51.2 <br />58.5 <br />No <br />R6 <br />Residential <br />34.3 <br />37.2 <br />43.3 <br />48.8 <br />56.0 <br />No <br />R7 <br />Residential <br />31.4 <br />34.2 <br />39.0 <br />43.6 <br />50.3 <br />No <br />Source: Urban Crossroads, 2019. Attachment A. <br />Conclusion for Noise <br />Consistent with the Original Project, the construction generated by the Modified Project would generate temporary <br />noise and vibration that would require mitigation to reduce impacts to a less than significant level. Also, due to the <br />location of the proposed residential units, mitigation is required to ensure that interior noise is within City standards. <br />With implementation mitigation identified in the EIR, potential impacts would be reduced to less than significant levels. <br />Based on the foregoing, none of the conditions identified in CEQA Guidelines Section 15088.5 that would trigger the <br />need to prepare a recirculated EIR or other environmental document exist. The Modified Project would not result in <br />either a new significant environmental impact or a substantial increase in the severity of a previously identified impact. <br />EIR Mitigation Measures <br />Mitigation Measure NO1-1: The Project plans and specifications shall include the following construction requirements <br />to be implemented and verified prior to provision of occupancy permits: <br />• Windows/Glass Doors: Residential units adjacent to N. Main Street (all floors) require upgraded windows and <br />sliding glass doors (all windows/doors on all floors) with minimum STC ratings of 30, and all other buildings <br />require standards windows and sliding glass doors with a minimum STC rating of 27. <br />• Exterior Doors (Non -Glass): Exterior doors facing N. Main Street (all floors) require upgraded exterior doors <br />with minimum STC ratings of 30 and shall be well weather-stripped, and all other residential building exterior <br />doors shall be well weather-stripped and have minimum STC ratings of 27. Well -sealed perimeter gaps <br />around the doors are essential to achieve the optimal STC rating. <br />• Walls: At any penetrations of exterior walls by pipes, ducts, or conduits, the space between the wall and <br />pipes, ducts, or conduits shall be caulked or filled with mortar to form an airtight seal. <br />• Ventilation: Residential exterior vents shall be oriented away from 1-5 and N. Main Street. If such an <br />orientation cannot be avoided, then an acoustical baffle shall be placed in the attic space behind the vents. <br />Mitigation Measure NO1-2: The Project plans and specifications shall include the following. requirements: <br />• Large loaded trucks and mobile equipment, such as bulldozers (greater than or equal to 80,000 pounds) shall <br />not be used within 50 feet of the eastern boundary of the Project site. Instead, smaller, rubber -tired mobile <br />equipment (less than 80,000 pounds) or equivalent alternative equipment shall be used within this area <br />during Project construction. <br />• All construction equipment, fixed or mobile, shall be equipped with properly operating and maintained <br />mufflers, consistent with manufacturers' standards. The construction contractor shall place all stationary <br />
The URL can be used to link to this page
Your browser does not support the video tag.