Laserfiche WebLink
<br />WATER & SEWER COMPARISON <br /> ONE BROADWAY PLAZA <br />SANTA ANA, CALIFORNIA <br /> <br />2 <br /> <br /> <br />II. CURRENT ENTITLED CONDITION <br /> <br />The property as currently entitled, consists of a mixed-use high-rise with offices & <br />executive office suits and various other uses. The section below describes the current <br />entitled demand for domestic water and wastewater service. <br /> <br />WATER SERVICE <br /> <br />There is a 12” water line adjacent to the project site in N. Broadway. <br /> <br />Land Use Unit Water Demand Factor (1) Area <br />(square feet) <br />Daily water Usage <br />(gpd) <br />Mixed-use 0.09 gpd/sf 518,003 sf 46,621 <br />Notes: <br />(1) Unit Water Demand Factor was taken from the City of Santa Ana Transit Zoning Code EIR (0.09 gpd/sf) <br /> <br /> <br /> <br />As shown above current entitled water demand at the project site is estimated to be <br />approximately 46,621 gallons per day (gpd). <br /> <br />WASTEWATER SERVICE <br /> <br />There is a 15” sewer line adjacent to the project site in N. Broadway. <br /> <br />Land Use Unit Water Demand Factor (1) Area <br />(square feet) Average Sewer Flow (gpd) <br />Mixed-use 0.0765 gpd/sf 518,003 sf 39,628 <br />Notes: <br />(1) Unit Water Demand Factor was taken from the City of Santa Ana Transit Zoning Code EIR (0.0765 gpd/sf) <br /> <br /> <br /> <br />As shown above existing average sewer flow at the project site is estimated to be <br />approximately 39,628 gallons per day (gpd). <br /> <br />5 - 267