Laserfiche WebLink
CONTROL SPECIFICATIONS <br />Control System ........................................................... ANGI CCS Compressor Control System <br />PLC Make / Model .................................................... Panel, Control, Compressor, Horner Electric RX371 <br />I/O <br />I/O Arrangement (Max I/O Indicated) ................. 24 DI / 16 DO / 20 AI / 4 AO <br />Mounting Location of Controller ............................ On-skid, UL NNNY, mounted in NEMA 3R Enclosure <br />Electrical Classification of Control Panel .............. Class I Div II Per NFPA 78 <br />Operator Interface ................................................... Panel mounted graphical display, pilot lamps and <br />key switches <br />Available Network Connections ............................ CsCAN, Ethernet, Modbus*, DeviceNet <br /> <br />INSTRUMENTATION <br />STANDARD INSTRUMENTATION: Analog: Inlet Pressure Transducer, Interstage Pressure Transducer, <br />Discharge Pressure Transducer, Interstage Discharge Pressure RTD, Compressor Oil Pressure Transducer. <br />OPTIONAL ANALOG INSTRUMENTATION INCLUDED: Enclosure Gas Level (%LEL). DIGITAL <br />INSTRUMENTATION: ESD Active Dry Contact, Hi Gas Level <br /> <br />ELECTRIC MOTOR <br />Manufacturer: WEG Baldor or Equal / Operating Speed – 1785 rpm /NEMA, TEFC, Class 1 DIV 2 / 3- <br />phase – 460/60 Hz <br /> <br /> <br />COMPRESSOR AREA EQUIPMENT <br /> <br />COMPRESSOR EQUIPMENT BASE AREA - Included <br />Compressor pad area is composed of a minimum of 12-18” concrete base (depending on compressor <br />configuration and local building codes). The compressor equipment base area will house compressors, <br />storage, priority panel, inlet gas dryers and gas meter assembly. <br /> <br />The area inside the compressor compound (around the concrete equipment pads) is finished with a <br />surface of ¾” river rock (asphalt or concrete finish optional). By code, the compressor area must be <br />protected by bollards or continuously connected guardrail. <br /> <br />ELECTRICAL EQUIPMENT BASE AREA –Included <br />The electrical equipment will be located a minimum of 15’ from the compressors and other gas-supplied <br />equipment. The electrical area will contain the following items: Service Entrance Main Disconnect, Motor <br />Starter Panel, and optional items, such as communications panel, power distribution panel and manual <br />transfer switches. <br /> <br />COMPRESSOR AND ELECTRICAL EQUIPMENT AREA PROTECTION - Included <br />When guardrail is chosen for protection posts are typically spaced 7' on center and are anchored 36" - <br />60" below the ground surface. Guardrail height is set at 36" above the surface level. The time-fill post will <br />be mounted in an 18" dia. x 3' deep concrete base. <br /> <br />If bollards are chosen for protection, the compressor pad area will include 3' tall - 4" concrete-filled steel <br />protective bollards anchored in an 18" diameter base, 3' in depth spaced 4' on center. The bollard is <br />covered in a safety yellow TruStar Energy-branded plastic sleeve. <br /> <br />CHAIN LINK FENCE: - Included A 6-foot high 2-1/4" x 11-1/2 ga. galvanized-steel fence will be installed <br />around the compressor / electrical equipment areas. Includes a lockable service gate. The gate size will <br />be 3-feet wide unless otherwise specified. <br />TruStarEnergy-10225 PhiladelphiaCourt,RanchoCucamonga,91730•909-793-3700•(fax)909-793.jj()56•www.trusatrenergy.com <br /> <br />