My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Item 23 - First One -Year Extension for Site Plan Review No. 2020-03 and Variance No. 2020-06
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2022
>
12/06/2022 Regular
>
Item 23 - First One -Year Extension for Site Plan Review No. 2020-03 and Variance No. 2020-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2024 4:26:33 PM
Creation date
8/14/2023 7:49:24 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Clerk of the Council
Item #
23
Date
12/6/2022
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
230
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Architecture + Planning <br />17911 Von Karman Ave. <br />Suite 200 <br />Irvine, CA 92614 <br />ktgy.com <br />949.851.2133 <br />KTGY Project No: 2017-0934 <br />Project Contact: Debbie Holland <br />Email: dholland@ktgy.com <br />Principal: Wil Wong <br />Project Designer: D. Schoolmeester <br />Project Director: Debbie Holland <br />Developer <br />EI7 OAK <br />INVES'1'?I• EN'I'S <br />4199 CAMPUS DRIVE <br />IRVINE, CA 92612 <br />PHONE NO. (714) 342-2502 <br />NA <br />TF <br />i <br />V_ <br />0 <br />N <br />Q <br />U <br />Q <br />Z <br />Q <br />Q <br />Z <br />Q <br />U) <br />w <br />U) <br />F_ <br />NT <br />w <br />Ln <br />Ln <br />015 <br />T_ <br />Nt <br />W <br />No. Date Description H <br />10 <br />00 <br />D <br />U) <br />Ise <br />W <br />2 <br />U <br />Z <br />Q <br />J <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />n <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />' <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />v, <br />D ARCX /,/ <br />LL <br />�0 <br />1171.4 <br />N <br />No. C29795 <br />C) <br />RENEWAL DATE <br />AUGUST 31, 2023 <br />9TF OF \F��� <br />� <br />CA�_ <br />License Stamp <br />o <br />BUILDING B WALL <br />SECTIONS <br />WALL SECTION NOTES FIRE STOPPING LEGEND <br />PENETRATIONS OF FIRE -RESISTIVE WALLS, FLOOR/CEILINGS <br />UL SERIES LISTING <br />1. STRUCTURAL MEMBERS SHOWN IN ARCHITECTURAL SECTIONS ARE AND ROOFICEILINGS SHALL BE PROTECTED AS REQUIRED IN <br />DIAGRAMMATIC IN NATURE AND SHOULD NOT BE RELIED UPON AS AN ACTUAL CBC SEC. 714. <br />REPRESENTATION OF STRUCTURAL MEMBERS. REFER TO STRUCTURAL PENETRATION CONC CONC & WOOD WOOD CAD <br />DRAWINGS FOR SIZES AND SPECIFIC CONFIGURATION OF STRUCTURAL DESCRIPTION FLOORS MASONRY FRAME FRAME FOR ADDITIONAL INFORMATION, SEE <br />MEMBERS. WALLS WALLS FLOORS <br />2. FOR FIRE RATINGS OF WALLS SEE SHEETS AO-11 THRU AO-25. ROUND BLANK C-AJ-0000 C-AJ-0000 W-L-0000 <br />OPENING <br />3. FOR ASSEMBLIES, FIRE RATINGS, LISTINGS AND RELATED CONSTRUCTION TO RECTANGULAR C-AJ-0000 C-AJ-0000 W-L-0000 <br />DETAILS SEE AD 28 AD 28 BLANK OPNG <br />4. COLUMNS & PRIMARY STRUCTURAL FRAME MEMBERS SHALL BE PROVIDED BLANK OPNG F-C-0000 SECTION LEGEND <br />WITH INDIVIDUAL ENCASEMENT FIRE PROTECTION AS REQUIRED BY CBC AD 28 WALL CHASE <br />SECTIONS 704. SINGLE PIPE C-AJ-0000 C-AJ-0000 W-L-1000 F-C-1000 <br />PENETRATION 2-HR FIRE BARRIER <br />MULTIPLE C-AJ-1000 C-AJ-1000 W-L-1000 F-C-8000 <br />TYPICALINSULATION VALUES PIPE PEN 3-HR HORIZONTAL SEPARATION <br />SINGLE PIPE F-C-1000 FRAMED ASSEMBLIES <br />WALL CHASE <br />INSULATION LOCATION VALUE DRAIN \ CMU <br />F-A-1000 - - - <br />PER IN FLR <br />ROOF I CEILING R-30 <br />BATH TUB CONCRETE <br />PER IN FLR F B 1000 F C 2000 <br />METAL STUD EXTERIOR WALL R-?? <br />TOILET PEN F-A-2000 F-C-2000 <br />WOOD STUD EXTERIOR WALL R-21 IN FLOOR <br />ROUND DUCT C-AJ-7000 C-AJ-7000 W-L-7000 F-C-7000 <br />INFORMATION ABOVE IS BASED ON ENERGY CALCULATIONS PROVIDED BY VCA GREEN, DATED PENETRATION <br />07/01/2021. GC TO VERIFY THE INFORMATION ABOVE IS CONSISTENT WITH THE MOST CURRENT ENERGY RECTANGULAR <br />CALCULATIONS. DUCT PEN C-AJ-7000 C-AJ-7000 W-L-7000 F-C-7000 <br />WALL SECTION 'A' I SCALE: 1/4° -O" I A <br />COPYRIGHT <br />A2-80 <br />
The URL can be used to link to this page
Your browser does not support the video tag.