Laserfiche WebLink
UNIT 0.1 (TYPE III) REFLECTED CEILING PLAN I SCALE:1/4"=V-0" g I UNIT 0.1 (TYPE IA) REFLECTED CEILING PLAN I SCALE:1/4"=V-0" 7 <br />UNIT 0.1 INTERIOR ELEVATIONS I SCALE: 1/4"=V-0" 16 <br />UNIT 0.1 ACCESSIBILITY PLAN I SCALE: 1 /4"=V-0" 15 <br />c <br />c <br />4 <br />c <br /><V <br />T <br />0 <br />N N <br />N <br />i <br />80 <br />c <br />4 <br />c <br />M <br />IQ, _h+" <br />UNIT 0.1 D PLAN (TYPE 111) I SCALE: 1/4"=V-0" 14 <br />10' C" <br />v o <br />� N <br />UNIT 0.1 C PLAN (TYPE IA) I SCALE: 1/4"=V-0" I 3 <br />1 A' -A" <br />UNIT 0.1 B (TYPE III) <br />iE: mlm <br />SCALE: 1/4"=1'-0" 12 <br />5-8 1 /2" 3'-5 1 /2" 3'-5 1 /2" 4'-4 1 /2" 1'-4" <br />1 <br />0 0 <br />LIVING <br />VINYL <br />6'-3" '-6" <br />0 <br />7'-5" <br />4" <br />1'- <br />ELEC <br />------------------ <br />� <br />� <br />LO <br />KITCHEN <br />VINYL <br />_� <br />� U4a <br />U6b i LAUNDRY <br />1 I VINYL 11 <br />Ufa LIJ <br />IIIIIIIII <br />5'-1" <br />U8d <br />CLOSET <br />VINYL <br />FF <br />BATH <br />VINYL <br />VERIFY <br />9'-1" 4" 1'- <br />- - <br />N/ <br />I <br />of <br />I <br />010 <br />010 <br />I <br />I <br />L-- <br />L <br />2'-10" <br />18'-4" <br />UNIT 0.1 A (TYPE IA) I SCALE: 1/4"=V-0" I 1 <br />UNIT PLAN KEYNOTES <br />FINISH CARPENTRY: MDF SHELF AND WOOD POLES U.N.O. CONFIRM SHELF HEIGHTS WITH OWNER <br />1.1 COAT CLOSET: (S & P) SHELF AND POLE MOUNTED @ 70" AFF <br />1.2 LINEN AT BATH: 3 SHELVES @ 40", 56" & 72" <br />1.3 WORK STATION <br />1.4 LINEN SHELVES: 5 SHELVES EQUALLY SPACED <br />1.5 BEDROOM CLOSET SHELVING: SEE PLAN FOR MORE INFORMATION <br />(S & P) - SINGLE SHELF AND POLE @ 70" AFF <br />(DS & DP) - DOUBLE SHELF AND DOUBLE POLE @ 42" & 84" AFF <br />(SS) - SHELF STACK: 5 SHELVES EQUALLY SPACED <br />MANUFACTURED CABINETRY: ALL EXPOSED FACES TO HAVE MATCHING FINISH <br />2.1 BASE CABINETS: SEE INTERIOR ELEVATIONS FOR MORE INFORMATION <br />2.2 UPPER CABINETS: SEE INTERIOR ELEVATIONS FOR MORE INFORMATION <br />2.3 15" WIDE BREADBOARDS <br />2.4 FULL HEIGHT PANTRY CABINET <br />FIXTURES & APPLIANCES <br />3.1 DOUBLE BASIN SINK W/ GARBAGE DISPOSAL. PROVIDE SHALLOW SINK W/ REAR DRAIN TO ALLOW FOR KNEE & <br />ETOE CLEARANCE. GC TO CONFIRM SINK WITH DISPOSAL INSTALLED WILL MEET KNEE & TOE CLEARANCE PER <br />6/AD-04. PROVIDE MIN. 30" OF COUNTERTOP FOR SINK INSTALLATION, REMOVABLE BASE CABINETS, SINGLE <br />LEVER FAUCET AND INSULATE / PROTECT SUPPLY & WASTE LINES. PROVIDE FINISH FLOORING BENEATH <br />REMOVABLE BASE CABINETS <br />3.2 24" WIDE DISHWASHER <br />3.3 30" WIDE SLIDE -IN ELECTRIC RANGE W/ 30" WIDE MICROWAVE / HOOD ABOVE W/ LIGHT & FAN TO <br />EVENT TO EXTERIOR <br />3.4 REFRIGERATOR <br />3.5 60"x32" FIBERGLASS TUB / SHOWER W/ 72" HIGH FIBERGLASS WAINSCOT. PROVIDE INTEGRAL REINFORCING <br />EFOR FUTURE GRAB BARS, SINGLE HAND SHOWER CONTROLS, STANDARD SHOWER HEAD AND CURTAIN ROD. <br />60"00" CLEAR ACCESSIBLE FIBERGLASS SHOWER PAN W/ 72" HIGH TILE SURROUND. PROVIDE REINFORCING <br />3.6 FOR FUTURE GRAB BARS, SINGLE HAND SHOWER CONTROLS, STANDARD SHOWER HEAD AND TEMPERED <br />GLASS ENCLOSURE. <br />3 LAVATORY: SINGLE LEVER FAUCET. TOP LIP OF SINK AT 34" MAX. REMOVABLE BASE CABINETS. PROVIDE <br />FINISH FLOORING BELOW REMOVABLE BASE CABINETS. INSULATE & PROTECT WATER & WASTE LINES. <br />3.8 42"x42" FIBERGLASS SHOWER PAN W/ 72" HIGH TILE SURROUND. TEMPERED GLASS ENCLOSURE. <br />4.1 18" WIDE TOWEL BAR @ 40" A.F.F. <br />4.2 24" WIDE TOWEL BAR @ 40" A.F.F. <br />4.3 TOILET PAPER HOLDER @ 19" A.F.F. <br />4.4 RECESSED MEDICINE CABINET <br />4.5 MIRROR <br />UNIT PLAN NOTES <br />1. ALL DIMENSIONS ARE TO THE FACE OF FRAMING (STRL SHT'G / FURRING STRIPS, AS OCCURS, OR <br />OPEN STUDS) U.N.O. <br />2. ALL DWELLING UNITS SHALL BE ADAPTABLE AND ON AN ACCESSIBLE ROUTE. FOR GENERAL <br />DWELLING UNIT ACCESSIBILITY INFORMATION, REFER TO AD 03 <br />3. EXTEND FLOORING UNDER SINKS AND LAVATORIES WITH REMOVABLE CABINET AND BASE. FINISH <br />END WALLS OF CABINETS FLANKING OPENING TO MATCH CABINET FACE, PRIME & PAINT EXPOSED <br />GYP. BOARD. WALL TO MATCH WALLS. INSTALL MATCHING BASE BOARD. <br />4. FOR RECESSED FIXTURES AND EQUIPMENT INSTALLED IN A RATED WALL REFER TO DETAIL AD XX <br />5. PROVIDE BACKING FOR ALL ACCESSORIES, HANDRAILS, GRAB BARS AND WINDOW COVERINGS. <br />6. MAINTAIN RATED FLOOR CONSTRUCTION AT PLUMBING CUTOUTS FOR TUBS IN WOOD FRAMED <br />FLOORS. <br />7. OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL, U.N.O. <br />8. KITCHEN SINK TO HAVE REAR -SET GARBAGE DISPOSAL WITH AIR -GAP FOR DISHWASHER - SEE <br />PLUMBING PLANS FOR FIXTURE SPECS. <br />9. CONTINUE DRYWALL TO NEAREST CORNER TO ALIGN FACE OF FINISH. <br />10. FOR SHOWER PAN AND FLOOR / CEILING ASSEMBLY, REFER TO DETAIL AD XX <br />11. NO RANGE HOOD VENTS, DRYER VENTS, COMBUSTION VENTS, OR HEATING VENTS ARE PERMITTED <br />IN FIRE WALLS. <br />12. CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT <br />REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO <br />ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS. <br />13. ALL KITCHEN FLOORING SHALL CONTINUE TO BACK WALLS OF REFRIGERATOR AND RANGE <br />ALCOVES. <br />14. VERIFY ALL APPLIANCE, FIXTURE DIMENSIONS AND INSTALLATION REQUIREMENTS PRIOR TO <br />FABRICATION AND INSTALLATION. <br />15. VERIFY MANUFACTURER'S AND U.L. APPROVED CLEARANCES BETWEEN SELECTED APPLIANCES <br />AND COMBUSTIBLE MATERIALS. <br />16. RECESSED CABINETS (MEDICINE, LAUNDRY PLUMBING, ELECTRIC PANELS, ICE MAKER BOX, ETC.) <br />OCCURRING IN FIRE -RATED WALLS SHALL BE INSTALLED TO MAINTAIN THE REQUIRED FIRE RATING. <br />17. SUBMIT CABINET, COUNTERTOP AND CABINET HARDWARE SAMPLES TO OWNER FOR REVIEW AND <br />APPROVAL. <br />UNIT PLAN LEGEND <br />XX DOOR REFERENCE <br />A7-11 <br />XX WINDOW REFERENCE A7 21 <br />LOW WALL (SEE PLAN FOR HEIGHT) <br />- <br />2X4 WALL <br />TTTITIITTTTr- <br />2X6 WALL <br />FURRED WALL <br />F.M.C. <br />FLOORING MATERIAL TRANSITION, PROVIDE TRANSITION STRIP <br />F <br />REQUIRED ACCESSIBLE CLEAR FLOOR SPACE PER CBC CH. 11A <br />L _J <br />ELEC <br />RECESSED ELECTRICAL SUB -PANEL, HIGHEST OPERABLE PART AT 48" <br />MAX. ABOVE FLOOR - SEE ELECTRICAL DRAWINGS FOR MORE <br />INFORMATION <br />ELECTRICAL RISER STUD BAY REQ'D ADJACENT TO SUB -PANEL WHEN <br />OCCURS IN 2x4 FRAMED WALL. <br />LV <br />RECESSED LOW VOLTAGE SUB -PANEL - SEE ELECTRICAL DRAWINGS FOR <br />0 <br />MORE INFORMATION <br />DESIGNATED BATH SHALL COMPLY WITH CBC SECTION 1134A.2 OPTION 1 <br />ITEMS 1 -12. NOTE: ALL OTHER BATHROOMS IN THE SAME UNIT SHALL <br />COMPLY WITH OPTION 2 ITEMS 8 -12. <br />UNIT RCP NOTES <br />1. REFER TO MECHANICAL DRAWINGS FOR INFORMATION REGARDING SUPPLY & RETURN AIR <br />REGISTERS, EXHAUST FANS AND OTHER HVAC EQUIPMENT. <br />2. REFER TO ELECTRICAL DRAWINGS FOR INFORMATION REGARDING LIGHT FIXTURES, SMOKE <br />DETECTORS, SWITCHES, ELECTRICAL CEILING BOXES AND THE LIKE. <br />3. CEILING HEIGHTS INDICATED ARE APPROXIMATE MEASURED BETWEEN FINISHED SURFACES. <br />6. APPLY 5/8" TYPE "X" GYP BOARD ON STUD WALLS EXTENDING IN TO SOFFITS PRIOR TO SOFFIT <br />INSTALLATION. <br />10. PROVIDE CEILING FINISHED WITH MAXIMUM FLAME SPREAD RATING REQUIRED BY CBC. <br />11. ALL GYP. BOARD INSTALLED PRELIMINARILY AND/OR PRIOR TO PRIOR TO TYPICAL <br />CONSTRUCTION SEQUENCING SHALL BE WEATHER RESISTANT AND NON -PAPER FACED. ADAX <br />12. WHERE OCCURS, INSTALL RECESSED LIGHTING IN RATED FLOOR/CEILING ASSEMBLIES PER <br />DETAIL <br />13. WHERE OCCURS, INSTALL DUCTWORK IN RATED FLOOR/CEILING ASSEMBLIES PER DETAIL <br />AD-XX <br />UNIT RCP PLAN LEGEND <br />PENDANT / HANGING LIGHT FIXTURE <br />JO JUNCTION BOX <br />o SURFACE MOUNTED LIGHT FIXTURE <br />Q RECESSED LIGHT FIXTURE <br />AD-XX <br />Fe WALL MOUNTED LIGHT <br />® DIFFUSER / FAN - SEE MECHANICAL FOR MORE INFORMATION <br />ACCESS PANEL <br />CEILING FAN <br />CEILING HEIGHT <br />SOFFIT ABOVE CABINETS (7'-0" CLR. A.F.F. U.N.O.) <br />.r <br />r GYPSUM BOARD LINED JOIST BAY <br />7' 8" SOFFIT, TYP TYPE III CONSTRUCTION <br />9'-0" CEILING AT TYPE IA 1 ST FLOOR <br />8'-6" CEILING AT TYPE IA 2ND FLOOR <br />�1 <br />Architecture + Planning <br />17911 Von Karman Ave. <br />Suite 200 <br />Irvine, CA 92614 <br />ktgy.com <br />949.851.2133 <br />KTGY Project No: 2017-0934 <br />Project Contact: Debbie Holland <br />Email: dholland@ktgy.com <br />Principal: Wil Wong <br />Project Designer: D. Schoolmeester <br />Project Director: Debbie Holland <br />Developer <br />ED OAK <br />INVFSTMFNTS <br />4199 CAMPUS DRIVE <br />IRVINE, CA 92612 <br />PHONE NO. (714) 342-2502 <br />1 <br />i <br />V_ <br />0 <br />N <br />Q <br />U <br />Q <br />z <br />Q <br />Q <br />z <br />Q <br />U) <br />I__ <br />w <br />w <br />U) <br />w <br />V_ <br />LO <br />06 <br />W <br />No. Date Description HC <br />G <br />W <br />U) <br />U <br />W <br />2 <br />U <br />z <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />v J <br />procedures are not followed. <br />S�D ARch l <br />ILL <br />T <br />N <br />No. C29795 <br />C) <br />RENEWAL DATE <br />AUGUST 31, 2023 <br />9�F of \� <br />CD <br />C A` <br />License Stamp <br />o <br />UNIT 0.1 PLANS AND <br />INTERIOR ELEVATIONS <br />A5-01 <br />I <br />COPYRIGHT (C <br />