Laserfiche WebLink
UNIT PLAN KEYNOTES <br />FINISH CARPENTRY: MDF SHELF AND WOOD POLES U.N.O. CONFIRM SHELF HEIGHTS WITH OWNER <br />36'-2" <br />36'-0" <br />1.1 COAT CLOSET: (S & P) SHELF AND POLE MOUNTED @ 70" AFF <br />12'-2" 12'-0" <br />12'-0" <br />5' -11" <br />6'-1" <br />6'-7" <br />5'-5" <br />1.2 LINEN AT BATH: 3 SHELVES @ 40", 56" & 72" <br />1 " <br />6'-6'-1 " <br />6'-1 " <br />5'-11 " <br />10'-1 " "11" <br />11" 10' 101, <br />1.3 WORKSTATION <br />11'-0' "11" 11" <br />1 '-10" <br />LINEN SHELVES: 5 SHELVES EQUALLY SPACED <br />1.5 BEDROOM CLOSET SHELVING: SEE PLAN FOR MORE INFORMATION <br />N N <br />N <br />(V <br />N <br />- <br />DECK <br />iv <br />N <br />DECK <br />N <br />(S & P) - SINGLE SHELF AND POLE @ 70" AFF <br />(DS & DP) -DOUBLE SHELF AND DOUBLE POLE @ 42" & 84" AFF <br />o <br />I <br />o <br />F7_ <br />Y <br />(SS) - SHELF STACK: 5 SHELVES EQUALLY SPACED <br />MANUFACTURED CABINETRY: ALL EXPOSED FACES TO HAVE MATCHING FINISH <br />w <br />I0 <br />a <br />I _ <br />_J <br />I <br />I <br />I <br />I <br />I <br />o� � <br />I <br />I <br />2.1 BASE CABINETS: SEE INTERIOR ELEVATIONS FOR MORE INFORMATION <br />I <br />_ <br />I <br />_ <br />2.2 UPPER CABINETS: SEE INTERIOR ELEVATIONS FOR MORE INFORMATION <br />I <br />o 910 <br />tN., � <br />�0111 <br />M <br />2.3 15" WIDE BREADBOARDS <br />N <br />I <br />I <br />� <br />I / <br />2.4 FULL HEIGHT PANTRY CABINET <br />❑ <br />IV <br />ao <br />; <br />I <br />o <br />FIXTURES & APPLIANCES <br />rNi <br />31 DOUBLE BASIN SINK W/ GARBAGE DISPOSAL. PROVIDE SHALLOW SINK W/ REAR DRAIN TO ALLOW FOR KNEE & <br />❑ <br />I <br />TOE CLEARANCE. GC TO CONFIRM SINK WITH DISPOSAL INSTALLED WILL MEET KNEE & TOE CLEARANCE PER <br />6/AD-04. PROVIDE MIN. 30" OF COUNTERTOP FOR SINK INSTALLATION, REMOVABLE BASE CABINETS, SINGLE <br />LEVER FAUCET AND INSULATE / PROTECT SUPPLY & WASTE LINES. PROVIDE FINISH FLOORING BENEATH <br />I <br />I <br />REMOVABLE BASE CABINETS <br />24" WIDE DISHWASHER <br />ih <br />I <br />I <br />❑ 30" WIDE SLIDE -IN ELECTRIC RANGE W/ 30" WIDE MICROWAVE / HOOD ABOVE W/ LIGHT & FAN TO <br />VENT TO EXTERIOR <br />I <br />I <br />3.4 REFRIGERATOR <br />------- <br />I <br />I <br />❑ 60"x32" FIBERGLASS TUB / SHOWER W/ 72" HIGH FIBERGLASS WAINSCOT. PROVIDE INTEGRAL REINFORCING <br />3.5 <br />FOR FUTURE GRAB BARS, SINGLE HAND SHOWER CONTROLS, STANDARD SHOWER HEAD AND CURTAIN ROD. <br />60"00" CLEAR ACCESSIBLE FIBERGLASS SHOWER PAN W/ 72" HIGH TILE SURROUND. PROVIDE REINFORCING <br />❑3.6 <br />FOR FUTURE GRAB BARS, SINGLE HAND SHOWER CONTROLS, STANDARD SHOWER HEAD AND TEMPERED <br />GLASS ENCLOSURE. <br />UNIT2.1 <br />L <br />SCALE: 1/4"=1'-0" <br />g <br />UNIT <br />2.1 F <br />SCALE: 1/4"=1'-0" <br />4 <br />3.7 TOP LIP OF SINK AT 34" MAX. REMOVABLE BASE CABINETS. PROVIDE <br />FINISH FLING BELOW R MOVABLEE BASE CABINETS. INSULATE & PROTECT WAT R& WASTE LINES. <br />3.8 42"x42" FIBERGLASS SHOWER PAN W/ 72" HIGH TILE SURROUND. TEMPERED GLASS ENCLOSURE. <br />ACCESSORIES <br />36'-2" <br />36'-0" <br />4.1 18" WIDE TOWEL BAR @ 40" A.F.F. <br />6'-1" 6'-1" '-8 1/2" 9'-0 1/2" 1'-3" <br />6'-1" <br />5'-11" <br />5'-11" <br />6'-1" <br />6'-7" <br />5'-5" <br />4.2 24" WIDE TOWEL BAR @ 40" A.F.F. <br />1'- 1/2" 10'-0 1/2" 9" <br />10'-1 "11" <br />11" 10' 10" <br />4.3 TOILET PAPER HOLDER @ 19" A.F.F. <br />RECESSED MEDICINE CABINET <br />N �_ <br />�_ N <br />&4 <br />DECK <br />LII <br />L-i <br />N <br />`4 <br />DECK <br />'� `4 <br />45 MIRROR <br />I I I I I I IIIII IIM= <br />I � _- IrI�� <br />a ' <br />� <br />LLI <br />Ir� <br />UNIT PLAN NOTES <br />4'-4" '-0" 3'-8" �' <br />I J � I <br />///JI <br />/ <br />o <br />I � N <br />I <br />i <br />I <br />°' <br />M <br />,iI <br />I <br />T 9 <br />M <br />1. ALL DIMENSIONS ARE TO THE FACE OF FRAMING (STRL SHT'G / FURRING STRIPS, AS OCCURS, OR <br />OPEN STUDS) U.N.O. <br />o <br />O <br />/ I <br />2. ALL DWELLING UNITS SHALL BE ADAPTABLE AND ON AN ACCESSIBLE ROUTE. FOR GENERAL <br />TEMP <br />DWELLING UNIT ACCESSIBILITY INFORMATION, REFER TO <br />AD 03 <br />I <br />I <br />3. EXTEND FLOORING UNDER SINKS AND LAVATORIES WITH REMOVABLE CABINET AND BASE. FINISH <br />o <br />&4 <br />i <br />; <br />I <br />I <br />o <br />M <br />0, <br />f/ <br />f, / <br />END WALLS OF CABINETS FLANKING OPENING TO MATCH CABINET FACE, PRIME & PAINT EXPOSED <br />GYP. BOARD. WALL TO MATCH WALLS. INSTALL MATCHING BASE BOARD. <br />I <br />I <br />4. FOR RECESSED FIXTURES AND EQUIPMENT INSTALLED IN A RATED WALL REFER TO DETAIL AD XX <br />I <br />I/ <br />5. PROVIDE BACKING FOR ALL ACCESSORIES, HANDRAILS, GRAB BARS AND WINDOW COVERINGS. <br />6. MAINTAIN RATED FLOOR CONSTRUCTION AT PLUMBING CUTOUTS FOR TUBS IN WOOD FRAMED <br />FLOORS. <br />7. OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL, U.N.O. <br />8. KITCHEN SINK TO HAVE REAR -SET GARBAGE DISPOSAL WITH AIR -GAP FOR DISHWASHER - SEE <br />r, <br />i <br />I <br />PLUMBING PLANS FOR FIXTURE SPECS. <br />I <br />9. CONTINUE DRYWALL TO NEAREST CORNER TO ALIGN FACE OF FINISH. <br />_______ <br />_______ <br />10. FOR SHOWER PAN AND FLOOR/ CEILING ASSEMBLY, REFER TO DETAIL ADXX <br />11. NO RANGE HOOD VENTS, DRYER VENTS, COMBUSTION VENTS, OR HEATING VENTS ARE PERMITTED <br />_______ <br />IN FIRE WALLS. <br />12. CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT <br />REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO <br />ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS. <br />13. ALL KITCHEN FLOORING SHALL CONTINUE TO BACK WALLS OF REFRIGERATOR AND RANGE <br />ALCOVES. <br />UNIT <br />2.1 J <br />SCALE: 1/4"=1'-0" <br />7 <br />UNIT <br />2.1 E <br />SCALE: 1/4"=1'-0" <br />3 <br />14. ALL FIX RE DIMENSIONS AND INSTALLATION REQUIREMENTS PRIOR TO <br />FVERIFY <br />ABRICATION ANAPPLIA <br />INSE, <br />T <br />15. VERIFY MANUFACTURER'S AND U.L. APPROVED CLEARANCES BETWEEN SELECTED APPLIANCES <br />36'-2" <br />36-0" <br />AND COMBUSTIBLE MATERIALS. <br />16. RECESSED CABINETS (MEDICINE, LAUNDRY PLUMBING, ELECTRIC PANELS, ICE MAKER BOX, ETC.) <br />12'-2" 12'-0" <br />12'-0" <br />12'-0" <br />12'-0" <br />12'-0" <br />OCCURRING IN FIRE -RATED WALLS SHALL BE INSTALLED TO MAINTAIN THE REQUIRED FIRE RATING. <br />6'-1" 6'-1" <br />6-10" <br />5'-2" <br />5'-11" <br />6'-1" <br />6'-7" <br />5'-5" <br />17. SUBMIT CABINET, COUNTERTOP AND CABINET HARDWARE SAMPLES TO OWNER FOR REVIEW AND <br />APPROVAL. <br />10'-1 " "11" <br />11" " 10' 10" <br />UNIT PLAN LEGEND <br />CV <br />N <br />DECK <br />N <br />N <br />DECK <br />N <br />DOOR REFERENCE <br />XX A7-11 <br />I LU <br />I <br />z o <br />I <br />WINDOW REFERENCE <br />A7 21 <br />0 <br />1 <br />0 <br />I <br />I <br />w <br />I <br />LOW WALL (SEE PLAN FOR HEIGHT) <br />I <br />I <br />I <br />0- <br />? <br />I <br />2X4 WALL <br />o <br />I <br />91 o <br />o w <br />I <br />w o <br />C0 <br />I <br />I <br />M M <br />CO v <br />I <br />M M <br />2X6 WALL <br />FURRED WALL AD XX <br />o <br />I <br />I <br />� <br />I <br />I <br />F.M.C. FLOORING MATERIAL TRANSITION, PROVIDE TRANSITION STRIP <br />r <br />REQUIRED ACCESSIBLE CLEAR FLOOR SPACE PER CBC CH. 11A <br />I I <br />ELEC RECESSED ELECTRICAL SUB -PANEL, HIGHEST OPERABLE PART AT 48" <br />MAX. ABOVE FLOOR - SEE ELECTRICAL DRAWINGS FOR MORE <br />INFORMATION <br />ELECTRICAL RISER STUD BAY REQ'D ADJACENT TO SUB -PANEL WHEN <br />OCCURS IN 2x4 FRAMED WALL. <br />LV RECESSED LOW VOLTAGE SUB -PANEL - SEE ELECTRICAL DRAWINGS FOR <br />0 MORE INFORMATION <br />DESIGNATED BATH SHALL COMPLY WITH CBC SECTION 1134A.2 OPTION 1 <br />ITEMS 1 -12. NOTE: ALL OTHER BATHROOMS IN THE SAME UNIT SHALL <br />COMPLY WITH OPTION 2 ITEMS 8 -12. <br />UNIT RCP NOTES <br />UNIT2.1 <br />H <br />SCALE: 1/4"=1'-0" <br />6 <br />UNIT <br />2.1 D <br />SCALE: 1/4"=1'-0" <br />2 <br />1. REFER TO MECHANICAL DRAWINGS FOR INFORMATION REGARDING SUPPLY & RETURN AIR <br />REGISTERS, EXHAUST FANS AND OTHER HVAC EQUIPMENT. <br />2. REFER TO ELECTRICAL DRAWINGS FOR INFORMATION REGARDING LIGHT FIXTURES, SMOKE <br />36'-2" <br />36'-2" <br />DETECTORS, SWITCHES, ELECTRICAL CEILING BOXES AND THE LIKE. <br />3. CEILING HEIGHTS INDICATED ARE APPROXIMATE MEASURED BETWEEN FINISHED SURFACES. <br />12'-2" 12'-0" <br />12'-0" <br />12'-2" <br />12'-0" <br />12'-0" <br />6. APPLY 5/8" TYPE "X" GYP BOARD ON STUD WALLS EXTENDING IN TO SOFFITS PRIOR TO SOFFIT <br />6'-1" 6'-1" 1'-6" 9'-01, 1'-6" <br />6-10" <br />5'-2" <br />6'-1" <br />6'-1" <br />6'-7" <br />5'-5" <br />INSTALLATION. <br />10. PROVIDE CEILING FINISHED WITH MAXIMUM FLAME SPREAD RATING REQUIRED BY CBC. <br />" 11'-4" <br />11'-0' q1l.11" <br />11" 10' 10" <br />11. ALL GYP. BOARD INSTALLED PRELIMINARILY AND/OR PRIOR TO PRIOR TO TYPICAL <br />_ <br />CONSTRUCTION SEQUENCING SHALL BE WEATHER RESISTANT AND NON -PAPER FACED. AD-XX <br />_ iv <br />N <br />_ _ <br />_ <br />12. WHERE OCCURS, INSTALL RECESSED LIGHTING IN RATED FLOOR/CEILING ASSEMBLIES PER <br />fV - <br />= <br />N <br />CV <br />N <br />DETAIL <br />_ <br />fV o <br />DECK Z <br />o (V <br />_ <br />N <br />_ <br />N <br />13. WHERE OCCURS, INSTALL DUCTWORK IN RATED FLOOR/CEILING ASSEMBLIES PER DETAIL <br />= <br />5� o <br />DECK <br />AD-XX <br />W <br />o <br />I <br />w <br />UNIT RCP PLAN LEGEND <br />3'-8" 4'-0" 4'-4" <br />I <br />- <br />I <br />U2a <br />I <br />- <br />PENDANT/ HANGING LIGHT FIXTURE <br />o <br />I i `� <br />I <br />cP o <br />F_ <br />o <br />I <br />I <br />I <br />T o <br />O JUNCTION BOX <br />co <br />I <br />==> <br />I <br />I <br />M Cl) <br />co <br />I <br />I <br />M M <br />o SURFACE MOUNTED LIGHT FIXTURE <br />TEMP <br />I <br />I <br />Q RECESSED LIGHT FIXTURE <br />AD XX <br />I <br />I <br />I <br />in <br />I <br />Fe WALL MOUNTED LIGHT <br />® DIFFUSER / FAN - SEE MECHANICAL FOR MORE INFORMATION <br />❑ ACCESS PANEL <br />CEILING FAN <br />CEILING HEIGHT <br />SOFFIT ABOVE CABINETS (7'-0" CLR. A.F.F. U.N.O.) <br />r r r r <br />r r r r GYPSUM BOARD LINED JOIST BAY <br />r r r r <br />7'-8" SOFFIT, TYP TYPE III CONSTRUCTION <br />9'-0" CEILING AT TYPE IA 1ST FLOOR <br />8' 6" CEILING AT TYPE IA 2ND FLOOR <br />UNIT 2.1 G <br />SCALE: 1/4"=1'-0" <br />5 <br />UNIT 2.1 Cj <br />SCALE: 1/4"=1'-0" <br />1 <br />Architecture + Planning <br />17911 Von Karman Ave. <br />Suite 200 <br />Irvine, CA 92614 <br />ktgy.com <br />949.851.2133 <br />KTGY Project No: 2017-0934 <br />Project Contact: Debbie Holland <br />Email: dholland@ktgy.com <br />Principal: Wil Wong <br />Project Designer: D. Schoolmeester <br />Project Director: Debbie Holland <br />Developer <br />ED OAK <br />INVESTMENTS <br />4199 CAMPUS DRIVE <br />IRVINE, CA 92612 <br />PHONE NO. (714) 342-2502 <br />1 <br />I <br />C) <br />N <br />Q <br />U <br />Q <br />z <br />Q <br />Q <br />z <br />Q <br />U) <br />F <br />w <br />U) <br />w <br />V_ <br />L0 <br />06 <br />No. Date Description <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />N- ARCy�TF <br />No. C29795 <br />RENEWAL DATE <br />AUGUST 31, 2023 <br />OF CAS\ <br />License Stamp <br />UNIT 2.1 PLANS AND <br />VARIATIONS <br />A5-22 <br />014 <br />N <br />N <br />1 <br />COPYRIGHT (D <br />