TRASH ROOM KEYNOTES <br />RUBBISH CHUTES - (3) 30" DIA, 16 GAUGE ALUMINIZED STEEL W/ DAMPING COMPOUND <br />ON THE CHUTE EQUAL TO SOUNDCOAT GP-1 SHOULD BE INCORPORATED AS PART OF <br />THE BID REQUIREMENT. DAMPING SHOULD BE 1/2" THICKNESS OF STEEL. PROVIDE <br />SPRINKLERS AT TOP INTAKE AND EVERY 2ND OPENING - PROVIDE FLUSHING SPRAY <br />HEAD AND A DISINFECTING AND SANITIZING UNIT <br />INTAKE DOOR-15"x18" STAINLESS STEEL FRONT BACK AND SKIRT, NOISELESS SELF -CLOSING, <br />BOTTOM -HINGED, HAND -OPERATED DOOR WITH ACCESSIBLE LEVER HANDLE, RUBBER DOOR BAFFLES <br />DOOR SHALL BE 1-1/2 HR RATED WITH EMBOSSED LETTERS "WASTE", "RECYCLE" OR "GREEN WASTE". <br />aCLEANING ACCESS DOOR -1-1/2 HOUR FIRE -RATED AT 4+ STORIES, 1 HOUR AT 3 STORIES OR <br />LESS, 15"x15" SIDE -HINGED STAINLESS STEEL BEARING A UL "B" LABEL (AT TOP FLOOR ONLY) TO <br />SANITIZE UNIT OVER TOP OF CHUTE DOOR. VERIFY LOCATION AND COORDINATE WITH CHUTE <br />MANUFACTURER. PROVIDE WATER SUPPLY AS REQUIRED BY CHUTE MANUFACTURER. <br />4 ] WASTE, GREEN WASTE OR RECYCLE BIN <br />5 TRASH CHUTE ATTACHMENT AT FLOOR FRAMING, BY MANUFACTURER. PROVIDE VIBRATION <br />ISOLATION OF THE TRASH CHUTE WHERE CONNECTED TO THE BUILDING EQUAL TO MASON <br />INDUSTRIES TYPE BR HAVING 0.2 INCHES OF STATIC DEFLECTION <br />aOPENING IN SLAB OR FLOOR FRAMING FOR MECHANICAL VENTILATION - SEE MECHANICAL PLANS <br />7 DISCHARGE: UL LABELED ACCORDION TYPE FIRE DAMPER <br />88 FLUSHING SPRAY HEAD <br />El <br />165 DEGREE SPRINKLERS: LOCATE AT TOP INTAKE, ALTERNATE INTAKES BELOW AND AT <br />FIRST INTAKE <br />10 FLOOR DRAIN <br />8 ] WALL PROTECTION: 10" HIGH X 6" WIDE CURB ALONG THE PERIMETER OF THE TRASH ROOM <br />g❑ TRASH COMPACTOR: VERIFY SIZE WITH OWNER'S WASTE MANAGEMENT PLAN. VERIFY <br />POWER REQUIREMENTS WITH ELECTRICAL ENGINEER PRIOR TO PURCHASE. SLAB UNDER <br />COMPACTOR IS TO BE FLAT. <br />10 HOSE BIB - SEE PLUMBING PLANS <br />TRASH ROOM NOTES <br />1. FACE OF FINISH SHALL BE FLUSH INSIDE OF SHAFT <br />2. ALL DIMENSIONS ARE TO THE FACE OF STUD, CMU OR CONCRETE, U.N.O. <br />3. TRASH TERMINATION ROOM FLOORS SHALL BE FINISHED WITH WATERPROOF DECK OR EPDXY <br />COATING. <br />4. WALLS SHALL BE FINISHED WITH WASHABLE WATERPROOF SURFACE SUCH AS FRP OR HIGH -GLOSS <br />ENAMEL PAINT TO 6-0" AFF. <br />5. ODOR CONTROL UNIT MOUNTED ON WALL OF THE TRASH TERMINATION ROOM. <br />6. DISINFECTING AND SANITIZING UNIT AT THE TOP OF THE CHUTE. <br />7. VERIFY ALL ACCESSORIES FOR TRASH TERMINATION ROOM WITH OWNER AND CONFIRM POWER <br />REQUIREMENTS WITH ELECTRICAL ENGINEER. <br />TRASH CHUTE DOOR ACCESSIBILITY NOTES: <br />1. MAXIMUM 5 POUNDS OPENING FORCE <br />2. DOOR HARDWARE SHALL NOT REQUIRE GRASPING PINCHING, TWISTING OF WRIST <br />3. DOOR HARDWARE CONTROLS SHALL BE 15"-48" ABOVE FINISH FLOOR TO THE HIGHEST OPERATING <br />MECHANISM <br />TRASH CHUTE ACCESS ROOM ACOUSTICAL NOTES: <br />4. DOORS TO THE TRASH CHUTE ROOM SHOULD HAVE ADJUSTABLE CLOSER THAT CAN BE ADJUSTED SO <br />THE DOOR DOES NOT SLAM. <br />5. DOOR TO THE TRASH CHUTE SHALL EMPLOY QUIET LATCHING. <br />6. PROVIDE SOUNDCOAT GP-1 COMPOUND OR EQUAL ON THE CHUTE. DAMPENING SHALL BE MIN 2 THE <br />THICKNESS OF THE STEEL. <br />LL'IG EN''TRIES TYPE BR HAVING 0.2 INCHES OF STATIC ISOLATION. <br />2X4 WOOD STUD FRAMING <br />2X6 WOOD STUD FRAMING <br />CMU WALL - SEE STRUCTURAL <br />CONCRETE WALL - SEE STRUCTURAL <br />EXTENT OF EXTERIOR CEMENT PLASTER FINISH <br />SOFFIT <br />DIAGONAL <br />HT AS INDICATED ED GYP. BID. CEILININ PLAN LEOXT/ R OR CEM N RATED CE STERASSEMBLY. OVER EXTRUDED <br />METAL LATH OCCURS AT LOBBIES WITH EXTERIOR WALL OPENINGS. SEE <br />ENLARGED PLANS FOR EXTENT. <br />r I <br />30" x48" CLEAR FLOOR AREA <br />L J <br />I <br />5'-0" DIAMETER TURN AROUND SPACE <br />ENLARGED PLAN REFERENCES <br />1. FOR WALL FIRE -RATINGS AND DETAIL REFERENCES, FIRE EXTINGUISHER <br />LOCATIONS AND FIRE ACCESS ANALYSIS, SEE SHEETS AO-11 THRU AO-25 . <br />2. FOR EXITING ANALYSIS INCLUDING OCCUPANT LOADS, EXIT SIGNS AND DOOR PANIC <br />HARDWARE LOCATIONS, SEE SHEETS AO-31 THRU AO-45. <br />Architecture + Planning <br />17911 Von Karman Ave. <br />Suite 200 <br />Irvine, CA 92614 <br />ktgy.com <br />949.851.2133 <br />KTGY Project No: 2017-0934 <br />Project Contact: Debbie Holland <br />Email: dholland@ktgy.com <br />Principal: Wil Wong <br />Project Designer: D. Schoolmeester <br />Project Director: Debbie Holland <br />Developer <br />EI7 OAK <br />4199 CAMPUS DRIVE <br />IRVINE, CA 92612 <br />PHONE NO. (714) 342-2502 <br />1 <br />TF <br />i <br />T_ <br />C) <br />N <br />Q <br />U <br />Q <br />z <br />Q <br />Q <br />z <br />Q <br />U) <br />LLI <br />0V <br />U) <br />F_ <br />ICT <br />LO <br />T_ <br />L0 <br />015 <br />T_ <br />Nt <br />No. Date Description <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />SED ARCyJl <br />* No. C29795 <br />RENEWAL DATE <br />AUGUST 31, 2023 <br />OF CAS\ <br />License Stamp <br />BUILDING B TRASH <br />CHUTE SECTIONS <br />Z <br />Q <br />J <br />`n <br />1r n <br />ILL <br />VM! <br />N <br />N <br />O <br />N <br />1 <br />O <br />00 <br />0 <br />BUILDING B TRASH ROOM SECTION <br />SCALE: 1/4"=V-0" I 1 <br />COPYRIGHT <br />BUILDING <br />B <br />A5-97 <br />