Laserfiche WebLink
TYPICAL DOOR ELEMENTS <br />DOOR <br />SCHEDULE <br />FOR <br />DETAILS- <br />SEE <br />"DOOR <br />STYLES" & "TYPICAL DOOR DETAILS" <br />DOOR NOTES <br />TYPICAL LOCATION OF DOOR AND GATE ELEMENTS IF THEY OCCUR <br />DOOR <br />FRAME <br />A. PUBLIC USE & COMMON USE AREA DOORS AND GATES <br />SEE DOOR STYLES FOR SPECIFIC DOOR ELEVATION <br />BOTTOM OF CLOS R <br />o / <br />HIGH VIEWPORT ** <br />/d <br />PUSH BUTTON * <br />- - - - - <br />° o - - - - - - -LOW - ** W X 2 <br />DEADBOLT X 0� Q <br />\ HARDWARE o X VIEWPORT X Q uJ 2 � <br />Lu Q <br />o� Q Lu o <br />z DOORSMOO_ ooLU 00 d <br />BOTTOM i i Co M L l - <br />- FIN FLR a 3 & 4 4 & 6 <br />A-510 A-520 <br />oz <br />UJ <br />d <br />Of <br />o <br />XX <br />ig� <br />2 <br />m <br />w z <br />¢ � Q <br />REMARKS <br />CBC CHAP 10, 11A DIV III AND 11 B DIV IV <br />GATES SHALL COMPLY WITH THESE NOTES AS REQUIRED FOR DOORS. <br />OPENING CLEARANCE <br />1. ALL ENTRANCE AND EXIT DOORS SHALL HAVE A MINIMUM CLEAR OPENING OF 32 INCHES WITH THE <br />DOOR OPEN 90 DEGREES FROM ITS CLOSED POSITION, MEASURED BETWEEN THE FACE OF THE DOOR <br />AND THE OPPOSITE STOP. (1008.1.1, 11B-404.2.3, 1126A.1.1) <br />4 <br />2. FOR ACCESSIBLE DOOR CLEARANCES REQUIREMENTS, SEE <br />EFFORT AD-02.0 <br />3. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR PUBLIC EXTERIOR <br />DOORS, 8'h POUNDS FOR COMMON AREA EXTERIOR DOORS, 5 POUNDS FOR INTERIOR DOORS, AND 15 <br />POUNDS FOR FIRE DOORS. (1008.1.3, 1126A.4, 11B-404.2.9) <br />HARDWARE <br />4. DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES THE DOOR <br />WILL TAKE AT LEAST 3 SECONDS TO MOVE TO APPOINT 3 INCHES FROM THE LATCH. (1126A.4.1, <br />11 B-404.2.8.1) <br />J <br />U <br />w <br />_ <br />U)Z <br />Z <br />v <br />= <br />a <br />w <br />¢ <br />CO <br />z <br />a <br />w <br />¢ <br />U) <br />z <br />DWELLING <br />UNIT <br />DOORS <br />U1a <br />A <br />3' 0" <br />6' 8" <br />1 3/4" <br />SC <br />SG <br />WOOD <br />SG <br />20 <br />UNIT ENTRY DOOR <br />U2a <br />C <br />3' 0" <br />8' 0" <br />1 3/4" <br />SC <br />SG <br />WOOD <br />SG <br />PATIO DOOR, TEMPERED GLAZING, DEAD BOLT, MAX. 0.45 U VALUE, MAX. 0.23 SHGC VALUE <br />U2b <br />C <br />3' 0" <br />8' 0" <br />1 3/4" <br />SC <br />SG <br />WOOD <br />SG <br />PATIO DOOR, TEMPERED GLAZING, INOPERABLE, MAX. 0.45 U VALUE, MAX. 0.23 SHGC VALUE <br />KICK PLATE MAY OCCUR 16 GA MAX, ANY FOR ADDITIONAL INFORMATION SEE DETAILS <br />U3a <br />B <br />3'-01, <br />6-8" <br />1 3/8" <br />HC <br />SG <br />WOOD <br />SG <br />BEDROOM, PRIVACY LOCK <br />THRESHOLDS <br />LCAVITIES CREATED SHALL BE CAPPED * REQUIRED AT ACCESSIBLE/ADAPTABLE DWELLING UNITS <br />NO PROJECTIONS INTO ** IF PROVIDED INSTALL TWO VIEWPORTS ONE HIGH ONE <br />CLEAR OPENING BELOW 34" LOW AT <br />ACCESSIBLE/ADAPTABLE DWELLING UNITS <br />5. THRESHOLD - LANDINGS SHALL NOT BE MORE THAN 1/2 INCH LOWER THAN THE TOP OF THE <br />THRESHOLD OF THE DOORWAY. CHANGES IN HEIGHT BETWEEN %AND Yz INCH SHALL BE BEVELED AT <br />A MAXIMUM 50%. CHANGES IN LEVEL GREATER THAN''/z INCH SHALL BE RAMPED. (1008.1.7, 1126A.2.1, <br />11 B-404.2.5) <br />U4a <br />B <br />3' 0" <br />6-8" <br />1 3/8" <br />HC <br />SG <br />WOOD <br />SG <br />BATHROOM, PRIVACY LOCK <br />U5a <br />B <br />T-0" <br />6'-8" <br />1 3/8" <br />HC <br />SG <br />WOOD <br />SG <br />CLOSET, PASSAGE HARDWARE <br />U6a <br />D <br />T-0" <br />6-8" <br />1 3/8" <br />HC <br />SG <br />WOOD <br />SG <br />WASHER/DRYER CLOSET, PASSAGE HARDWARE <br />B. DWELLING UNIT DOORS <br />PRIMARY ENTRANCE DOOR INTO AND DOORS WITHIN INDIVIDUAL DWELLING UNITS <br />6. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 8'/z POUNDS FOR EXTERIOR DOORS, 5 <br />DOOR STYLES <br />U6b <br />D <br />2'-8" <br />6'-8" <br />1 3/8" <br />HC <br />SG <br />WOOD <br />SG <br />WASHER/DRYER CLOSET, PASSAGE HARDWARE <br />POUNDS FOR INTERIOR DOORS, AND 15 POUNDS FOR FIRE DOORS. <br />7. DOORS FROM INDIVIDUAL DWELLING OR SLEEPING UNITS IN GROUP R OCCUPANCIES HAVING AN <br />U7a <br />B <br />3' 0" <br />68" <br />1 3/8" <br />HC <br />SG <br />WOOD <br />SG <br />COAT CLOSET, PASSAGE HARDWARE <br />OCCUPANT LOAD OF 10 OR LESS ARE PERMITTED TO HAVE A NIGHT LATCH, DEAD BOLT OR SECURITY <br />CHAIN PROVIDED SUCH DEVICES ARE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR <br />U7b <br />B <br />2'-10" <br />6-8" <br />1 3/8" <br />HC <br />SG <br />WOOD <br />SG <br />COAT CLOSET, PASSAGE HARDWARE <br />TOOL (1008.1.9.3.4) AND ARE OPERABLE WITH A SINGLE EFFORT OF THE DOOR LEVER. (1132A.8) <br />8. DOOR BUZZER, BELL, CHIME OR EQUIVALENT SHALL BE PROVIDED AT EVERY PRIMARY ENTRANCE <br />U7c <br />B <br />2'-8" <br />6-8" <br />1 3/8" <br />HC <br />SG <br />WOOD <br />SG <br />COAT CLOSET, PASSAGE HARDWARE <br />DOOR. (1132A.10) <br />9. THRESHOLD - SECONDARY EXTERIOR DOORS OF DWELLING UNITS SHALL BE NO HIGHER THAN INCH <br />U8a <br />E <br />10'-4" <br />6'-8" <br />1 3/8" <br />HC <br />SG <br />WOOD <br />SG <br />BY-PASS, 4 PANELS <br />U8b <br />E <br />8' 0" <br />6' 8" <br />1 3/8" <br />HC <br />SG <br />WOOD <br />SG <br />BY-PASS <br />' <br />FOR SLIDING DOORS OR FOR OTHER DOORS. CHANGES IN HEIGHT BETWEEN 1/4AND 3/4 INCH SHALL <br />BE BEVELED AT A MAXIMUM 50%. (1008.1.7, 1132A.4.1) <br />U8c <br />E <br />T-0" <br />6-8" <br />1 3/8" <br />HC <br />SG <br />WOOD <br />SG <br />BY-PASS <br />TEMP <br />o <br />o 0 GL o 0 <br />o o <br />10. ENTRANCE DOORS FROM INTERIOR CORRIDORS TOGETHER WITH THEIR PERIMETER SEALS SHALL <br />HAVE A LABORATORY STC RATING OF NOT LESS THAN 26. SUCH TESTED DOORS SHALL OPERATE <br />NORMALLY WITH COMMERCIALLY AVAILABLE SEALS UNLESS OTHERWISE REQUIRED BY AN <br />ACOUSTICAL REPORT. (1207.7) <br />U8d <br />E <br />6' 0" <br />68" <br />1 3/8" <br />HC <br />SG <br />WOOD <br />SG <br />BY-PASS <br />U8e <br />E <br />5'-0" <br />6'-8" <br />1 3/8" <br />HC <br />SG <br />WOOD <br />SG <br />BY-PASS <br />11. DOORS ON AN ACCESSIBLE ROUTE SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE <br />U8f <br />E <br />4'-0" <br />6'-8" <br />1 3/8" <br />HC <br />SG <br />WOOD <br />SG <br />BY-PASS <br />HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS OR OTHER HARDWARE DESIGNED TO PROVIDE <br />PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP, TIGHT PINCHING OR TWISTING OF THE WRIST <br />TO OPERATE THE OPENING HARDWARE <br />A B C D E <br />12. LEVER -TYPE HARDWARE SHALL BE CURVED WITH A RETURN TO WITHIN'/2 INCH OF THE DOOR EXCEPT <br />IN GROUP R AND U OCCUPANCIES WITH AN OCCUPANT LOAD OF 10 OR LESS. <br />ENTRY DOOR INTERIOR DOOR FRENCH DOOR LOUVERED DOOR BY-PASS DOOR <br />13. HARDWARE SHALL BE INSTALLED BETWEEN 34 MINIMUM TO 44 INCHES MAXIMUM ABOVE FINISHED <br />FLOOR. <br />14. EGRESS DOORS IN PAIRS, APPROVED AUTOMATIC FLUSH BOLTS SHALL BE PERMITTED PROVIDED <br />THAT THE DOOR LEAF HAVING THE AUTOMATIC FLUSH BOLTS HAS NO DOORKNOB OR SURFACE <br />MOUNTED HARDWARE. <br />15. EGRESS DOORS - MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED. <br />16. FIRE DOORS AND BOTH LEAVES OF PAIRS OF SIDE HINGED SWINGING FIRE DOORS SHALL BE <br />PROVIDED WITH AN ACTIVE LATCH BOLT THAT WILL SECURE THE DOOR WHEN IT IS CLOSED. <br />17. FIRE DOORS SHALL BE SELF -CLOSING OR AUTOMATIC CLOSING. AUTOMATIC -CLOSING FIRE DOORS <br />ASSEMBLIES SHALL BE SELF -CLOSING IN ACCORDANCE WITH NFPA 80 <br />18. SMOKE ACTIVATED DOORS - AUTOMATIC CLOSING DOORS SHALL CLOSE BY THE ACTUATION OF SMOKE <br />DETECTORS IN ACCORDANCE WITH SECTION 907.3 OR BY LOSS OF POWER. <br />19. INSTALL DOOR HARDWARE IN COMPLIANCE WITH MANUFACTURER'S INSTALLATION REQUIREMENTS. <br />20. PROTECT ALL THRESHOLDS COMPONENTS FROM DIRECT CONTACT WITH DISSIMILAR METALS AND <br />CORROSIVE MATERIALS PER MANUFACTURER'S RECOMMENDATIONS. <br />21. DOORS ON AN ACCESSIBLE ROUTE: THE BOTTOM 10 INCHES MINIMUM OF ALL DOORS AND OR GATES <br />SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR OR GATE TO BE OPENED BY <br />A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. <br />22. GLAZING IN DOORS SHALL COMPLY WITH SAFETY GLAZING (2406) RATINGS <br />23. FIRE DOOR ASSEMBLIES THAT ARE SIDE HINGED OR PIVOTED SWINGING SHALL BE TESTED IN <br />ACCORDANCE WITH NFPA 252 OR UL 10C. <br />24. FIRE DOOR ASSEMBLIES WITH OTHER TYPES OF DOORS INCLUDING SWINGING ELEVATOR DOORS AND <br />FIRE SHUTTER ASSEMBLIES SHALL BE TESTED IN ACCORDANCE WITH NFPA 252 OR UL10B <br />25. FIRE DOOR ASSEMBLIES REQUIRED TO HAVE A MINIMUM FIRE PROTECTION RATING OF 20 MINUTES <br />WHERE LOCATED IN A CORRIDOR OR SMOKE BARRIER WALLS HAVING A FIRE RESISTANCE RATING IN <br />ACCORDANCE WITH TABLE 715.4 SHALL BE TESTED IN ACCORDANCE WITH NFPA 252 OR UL 10C <br />WITHOUT THE HOSE STREAM TEST. <br />26. SMOKE AND DRAFT CONTROL - FIRE DOOR ASSEMBLIES REQUIRED TO HAVE A MINIMUM FIRE <br />PROTECTION RATING OF 20 MINUTES WHERE LOCATED IN A CORRIDOR OR SMOKE BARRIER WALLS <br />SHALL MEET THE REQUIREMENTS FOR SMOKE AND DRAFT CONTROL DOOR ASSEMBLIES TESTED IN <br />ACCORDANCE WITH UL 1784 <br />27. GLAZING IN DOOR ASSEMBLY - IN 20 MINUTE FIRE DOOR ASSEMBLY, THE GLAZING MATERIAL IN THE <br />DOOR ITSELF SHALL HAVE A MINIMUM FIRE -PROTECTION -RATED -GLAZING OF 20 MINUTES. <br />28. FIRE DOOR ASSEMBLIES IN EXIT ENCLOSURES AND EXIT PASSAGE WAYS SHALL HAVE A MAXIMUM <br />TRANSMITTED TEMPERATURE END POINT OF NOT MORE THAN 450 F DEGREES. THIS IS NOT REQUIRED <br />WHEN BUILDING IS EQUIPPED THROUGHOUT WITH AN NFPA 13 AUTOMATIC SPRINKLER SYSTEM. <br />29. DOOR FRAMES WITH TRANSOM LIGHTS, SIDELIGHTS OR BOTH, SHALL BE PERMITTED WHERE A'/4 HOUR <br />FIRE PROTECTION RATING OR LESS IS REQUIRED. WHERE A FIRE PROTECTION RATING EXCEEDING % <br />HOUR IS REQUIRED FIRE DOOR FRAMES WITH TRANSOM LIGHTS, SIDELIGHTS OR BOTH SHALL BE <br />INSTALLED WITH FIRE -RESISTANCE -RATED GLAZING TESTED AS AN ASSEMBLY IN ACCORDANCE WITH <br />ASTM El19 OR UL 263. <br />30. DOORS THAT ARE PART OF A FIRE RATED WALL ASSEMBLY SHALL COMPLY WITH OPENING <br />PROTECTIVES. <br />LABELS <br />31. FIRE DOOR ASSEMBLIES SHALL BE LABELED BY AN APPROVED AGENCY. THE LABELS SHALL COMPLY <br />WITH NFPA 80 AND SHALL BE PERMANENTLY AFFIXED TO THE DOOR OR FRAME. <br />32. FIRE DOORS SHALL BE LABELED SHOWING THE NAME OF THE MANUFACTURER, THE NAME OR <br />TRADEMARK OF THE THIRD -PARTY INSPECTION AGENCY, THE FIRE PROTECTION RATING AND WHERE <br />REQUIRED FOR FIRE DOORS IN EXIT ENCLOSURES AND EXIT PASSAGEWAYS THE MAXIMUM <br />TRANSMITTED TEMPERATURE END POINT. LABELS SHALL BE APPROVED AND PERMANENTLY AFFIXED <br />AND FACTORY APPLIED. SMOKE AND DRAFT CONTROL DOORS COMPLYING WITH UL 1784 SHALL SHOW <br />THE LETTER "S" ON THE FIRE RATED LABEL. <br />33. OVERSIZED FIRE DOORS SHALL BEAR AN OVERSIZED FIRE DOOR LABEL BY AN APPROVED AGENCY OR <br />SHALL BE PROVIDED WITH A CERTIFICATE OF INSPECTION BY AN APPROVED TESTING AGENCY. <br />34. FIRE DOOR FRAMES SHALL BE LABELED SHOWING THE NAME OF THE MANUFACTURER AND THE <br />THIRD -PARTY INSPECTION AGENCY. <br />35. GLAZING - FIRE -PROTECTION- RATED GLAZING SHALL BEAR A LABEL OR OTHER IDENTIFICATION <br />SHOWING THE NAME OF THE MANUFACTURER, THE TEST STANDARD AND THE FOLLOWING FOUR PART <br />IDENTIFICATION ISSUED BY AN APPROVED AGENCY AND PERMANENTLY AFFIXED TO THE GLAZING. <br />THE LABEL SHALL BEAR THE FOLLOWING FOUR PART IDENTIFICATION: <br />"D-HORNH -TORNT-XXX" <br />D INDICATES THE GLAZING SHALL BE USED IN FIRE DOORS PER NFPA 252 <br />H OR NH INDICATES THE GLAZING MEETS OR DOES NOT MEET THE HOSE STREAM TEST <br />T OR NT INDICATES THE GLAZING MEETS OR DOES NOT MEET THE TEMPERATURE REQUIREMENTS <br />XXX INDICATES THE FIRE -PROTECTION -RATING PERIOD IN MINUTES. <br />36. EXTERIOR DOORS SHALL BE INSTALLED BEARING MANUFACTURER'S CERTIFICATE OF COMPLIANCE <br />WITH SPECIFIED THERMAL AND ACOUSTICAL REQUIREMENTS. <br />WEATHERIZATION <br />37. DOORS SHALL HAVE ALL SIX SIDES FACTORY PRIMED OR SEALED AFTER HARDWARE PREPARATION. <br />RESEAL ALL SURFACES IMMEDIATELY AFTER INSTALLATION. <br />38. EXTERIOR DOORS SHALL BE INSULATED AND FULLY WEATHER STRIPPED. <br />39. REFER TO REFERENCED DETAILS OF EXTERIOR DOORS FOR INTEGRATION WITH EXTERIOR WALL AND <br />THRESHOLD FLASHING SYSTEMS. <br />40. INSULATE SHIM CAVITY AROUND EXTERIOR DOORS WITH LOW EXPANSION FOAM. <br />41. FOR DOOR/ FRAME ASSEMBLIES IN C.M.U. VERIFY MASONRY OPENING DIMENSIONS. <br />42. PROVIDE SEPARATION BY A TIGHT FITTING DOOR BETWEEN FOOD PREPARATION AREA(S) (INCLUDING <br />FOOD STORAGE ROOMS) AND TOILET ROOM(S). SECTION 302.6 <br />GLAZING PERFORMANCE <br />GLAZING LOCATION <br />U VALUE <br />SHGC <br />EXTERIOR DOORS <br />.45 <br />.23 <br />BLDG A STOREFRONT <br />.46 <br />.22 <br />BLDG B STOREFRONT <br />.46 <br />.22 <br />DOOR STC RATINGS <br />LIVING UNIT ENTRY DOORS AND PATIO DOORS SHALL BE SOUND -RATED, PROVIDING A MINIMUM <br />STC RATING WHEN IN THE CLOSED POSITION. IN ACCORDANCE WITH THE ACOUSTICAL REPORT. <br />TYPICAL DOOR OPENINGS <br />DOOR ABBREVIATIONS <br />2-HR 1-HR <br />X X X <br />AL ALUMINUM P PAINT <br />AD-XX AD-XX AD-XX / \ <br />/ <br />X <br />/ AD-XX / \ <br />X / \ <br />AD-XX TEMP TEMP <br />AN ANODIZED PASS PASSAGE <br />AUTO AUTOMATIC CLOSING PB PUSH BUTTON <br />ECA ELECTRONIC CONTROL ACCESS PFSF PRE -FINISHED STEEL FRAME <br />F FACTORY PH PANIC HARDWARE <br />FGL FIBERGLASS PR PAIR <br />FF FACTORY FINISH PRIV PRIVACY LOCK <br />FX FIXED S STAIN <br />V GL GL / <br />X L------J L------J <br />\ AD XX X <br />FIR FRENCH DOOR SC SOLID CORE <br />GL GLASS SELF SELF CLOSING <br />HC HOLLOW CORE SG SEMI -GLOSS PAINT <br />HM HOLLOW METAL STRF STORE FRONT <br />AD XX \ <br />MA MASONITE TG TEMPERED GLASS <br />MC MINERAL CORE TS TUBE STEEL <br />UNIT FIRE DOOR X STOREFRONT <br />DOOR AD XX DOOR <br />MTL METAL WD WOOD <br />N/R NON -RATED <br />OCG OVERHEAD COILING GRILLE <br />OCD OVERHEAD COILING DOOR <br />Architecture + Planning <br />17911 Von Karman Ave. <br />Suite 200 <br />Irvine, CA 92614 <br />ktgy.com <br />949.851.2133 <br />KTGY Project No: 2017-0934 <br />Project Contact: Debbie Holland <br />Email: dholland@ktgy.com <br />Principal: Wil Wong <br />Project Designer: D. Schoolmeester <br />Project Director: Debbie Holland <br />Developer <br />EI7 OAK <br />INVES'1'1%,iEN'1'S <br />4199 CAMPUS DRIVE <br />IRVINE, CA 92612 <br />PHONE NO. (714) 342-2502 <br />1 <br />TF <br />V_ <br />O <br />N <br />Q <br />U <br />Q <br />z <br />Q <br />Q <br />z <br />Q <br />U) <br />LU <br />U) <br />F_ <br />NT <br />w <br />Ln <br />Ln <br />06 <br />T_ <br />Nt <br />No. Date Description <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />SED ARC,yjT <br />�G R <br />No. C29795 <br />RENEWAL DATE <br />AUGUST 31, 2023 <br />s�gTF <br />�F CAS\ <br />License Stamp <br />DWELLING UNIT DOOR <br />SCHEDULE <br />A7-00 <br />z <br />Q <br />J <br />U) <br />Ir-n <br />0. <br />ILL <br />0 <br />N <br />1 <br />Ir- <br />C) <br />00 <br />C) <br />COPYRIGHT (C <br />