Laserfiche WebLink
TYPICAL DOOR ELEMENTS <br />DOOR SCHEDULE FOR DETAILS- SEE "DOOR STYLES" & "TYPICAL DOOR DETAILS" <br />DOOR NOTES <br />DOOR <br />FRAME <br />DOOR <br />FRAME <br />A. PUBLIC USE & COMMON USE AREA DOORS AND GATES <br />TYPICAL LOCATION OF DOOR AND GATE ELEMENTS IF THEY OCCUR <br />SEE DOOR STYLES FOR SPECIFIC DOOR ELEVATION <br />0 BOTTOM OF CLOS R <br />HIGH VIEWPORT ** <br />' PUSH BUTTO * <br />° - - - - Z <br />/ o <br />- - ** <br />&______� - DEADBOLT LOW Q <br />HARDWARE 0 VIEWPORT X X w co <br />w Q _ <br />SMOO" <br />z DOOR r- \ Mw � a <br />BOTTOM / I �I LU iv <br />FIN FLR a 3 & 4 4 & 6 <br />A 510 A 520 <br />MAY OCCUR 16 GA MAX, ANY FOR ADDITIONAL INFORMATION SEE DETAILS KICK PLATE <br />CAVITIES CREATED SHALL BE CAPPED * REQUIRED AT ACCESSIBLE/ADAPTABLE DWELLING UNITS <br />NO PROJECTIONS INTO ** IF PROVIDED INSTALL TWO VIEWPORTS ONE HIGH ONE <br />CLEAR OPENING BELOW 34" LOW AT <br />ACCESSIBLE/ADAPTABLE DWELLING UNITS <br />`�' <br />0 <br />w <br />o <br />0 <br />0 <br />0 <br />XX <br />6 <br />w w <br />z <br />} - <br />m <br />coSQ z <br />U„ a <br />Q <br />REMARKS <br />� <br />0 <br />> <br />I,, <br />o <br />0 <br />0 <br />XX <br />6 <br />w w <br />z <br />- <br />m <br />W z <br />¢ <br />REMARKS <br />CBC CHAP 10, 11A DIV III AND 11B DIV IV <br />GATES SHALL COMPLY WITH THESE NOTES AS REQUIRED FOR DOORS. <br />OPENING CLEARANCE <br />1. ALL ENTRANCE AND EXIT DOORS SHALL HAVE A MINIMUM CLEAR OPENING OF 32 INCHES WITH THE <br />DOOR OPEN 90 DEGREES FROM ITS CLOSED POSITION, MEASURED BETWEEN THE FACE OF THE DOOR <br />AND THE OPPOSITE STOP. (1008.1.1, 11B 404.2.3, 1126A.1.1) <br />4 <br />2. FOR ACCESSIBLE DOOR CLEARANCES REQUIREMENTS, SEE <br />EFFORT AD02.0 <br />3. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 5 POUNDS FOR PUBLIC EXTERIOR <br />DOORS, 8 /z POUNDS FOR COMMON AREA EXTERIOR DOORS, 5 POUNDS FOR INTERIOR DOORS, AND 15 <br />POUNDS FOR FIRE DOORS. (1008.1.3, 1126A.4, 11B-404.2.9) <br />HARDWARE <br />4. DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES THE DOOR <br />WILL TAKE AT LEAST 3 SECONDS TO MOVE TO APPOINT 3 INCHES FROM THE LATCH. (1126A.4.1, <br />11 B-404.2.8. 1) <br />THRESHOLDS <br />5. THRESHOLD - LANDINGS SHALL NOT BE MORE THAN 1/2 INCH LOWER THAN THE TOP OF THE <br />THRESHOLD OF THE DOORWAY. CHANGES IN HEIGHT BETWEEN'/4 AND INCH SHALL BE BEVELED AT <br />A MAXIMUM 50%. CHANGES IN LEVEL GREATER THAN'/z INCH SHALL BE RAMPED. (1008.1.7, 1126A.2.1, <br />11 B-404.2.5) <br />z <br />0 <br />I- <br />v <br />0 <br />J <br />W <br />cn <br />2 <br />� <br />= <br />w <br />_ <br />U) <br />cn <br />z <br />Y <br />v <br />_ <br />J <br />a <br />!Y <br />~ <br />¢ <br />= <br />� <br />z <br />J <br />a <br />!Y <br />~ <br />¢ <br />= <br />z <br />0 <br />I- <br />v <br />W <br />} <br />u~i <br />= <br />o <br />= <br />_ <br />U) <br />z <br />Y <br />v <br />a <br />LU <br />U) <br />a <br />LU <br />U) <br />BUILDING <br />A <br />DOORS <br />BUILDING <br />A <br />DOORS <br />� <br />O <br />0 <br />LL J <br />U) <br />0� <br />LL <br />A101 <br />RESTAURANT <br />C <br />T-0" <br />PAIR <br />10' 0" <br />AL <br />FF <br />AL <br />FF <br />DOOR TO REMAIN UNLOCKED DURING BUSINESS <br />HOURS <br />0 <br />w <br />Z) <br />z <br />z <br />� <br />U <br />� <br />A316 <br />ELEVATOR 2 / CORRIDOR <br />E <br />T-6" <br />T-0" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />MAGNETIC HOLD OPEN, CLOSES UPON FIRE <br />ALARM ACTIVATION <br />A102 <br />STAIR A4 DISCHARGE <br />B <br />T-0" <br />8'-0" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />PANIC HARDWARE, CONTROLLED ACCESS <br />A317 <br />OF / CORRIDOR <br />A <br />PAIR <br />6-8 <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />Al03 <br />RESTAURANT / STAIR A4 <br />A <br />T-0" <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE <br />A318 <br />STAIR A3 ACCESS <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE <br />A104 <br />CORRIDOR / STAIR A4 <br />B <br />3' 0" <br />6' 8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE <br />A319 <br />CORRIDOR FIRE WALL <br />E <br />T-0" <br />PAIR <br />6' 8" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />180 <br />DUAL EGRESS, MAGNETIC HOLD OPEN, CLOSES <br />UPON FIRE ALARM ACTIVATION <br />Al <br />Al05 <br />RESTAURANT <br />B <br />3 <br />6'-8" <br />- <br />HM <br />SGP <br />HM <br />SGP <br />- <br />DOUBLE SWING DOORS <br />A320 <br />OF / CORRIDOR <br />A <br />2 <br />PAIR <br />6' -8" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />A106 <br />CORRIDOR / EXTERIOR <br />C <br />T-0" <br />PAIR <br />8-0' <br />AL <br />FF <br />AL <br />FF <br />PANIC HARDWARE, CONTROLLED ACCESS <br />A321 <br />STAIR A2 ACCESS <br />B <br />T-0" <br />6'-8" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE <br />A107 <br />TRASH ROOM <br />D <br />16-0" <br />16-0" <br />- <br />- <br />0 <br />0 <br />A322 <br />STAIR A2 ACCESS <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />180 <br />PANIC HARDWARE <br />B. DWELLING UNIT DOORS <br />PRIMARY ENTRANCE DOOR INTO AND DOORS WITHIN INDIVIDUAL DWELLING UNITS <br />6. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 8 /2 POUNDS FOR EXTERIOR DOORS, 5 <br />DOOR STYLES <br />Al <br />TRASH ROOM / CORRIDOR <br />A <br />T-0" <br />6'-8" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />CONTROLLED ACCESS <br />A323 <br />STAIR Al ACCESS <br />B <br />T-0" <br />6'-8" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE, CONTROLLED ACCESS INTO <br />GARAGE <br />A109 <br />RESTAURANT /CORRIDOR <br />A <br />3' 0" <br />68" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />CONTROLLED ACCESS <br />POUNDS FOR INTERIOR DOORS, AND 15 POUNDS FOR FIRE DOORS. <br />7. DOORS FROM INDIVIDUAL DWELLING OR SLEEPING UNITS IN GROUP R OCCUPANCIES HAVING AN <br />0 <br />1/ <br />OCCUPANT LOAD OF 10 OR LESS ARE PERMITTED TO HAVE A NIGHT LATCH, DEAD BOLT OR SECURITY <br />CHAIN PROVIDED SUCH DEVICES ARE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR <br />A110 <br />MPOE /CORRIDOR <br />A <br />3' 0" <br />6' 8" <br />1 3l4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />------�------�------� <br />I I i <br />I I I <br />� i � i i i I I I <br />I I 1 I I I <br />�il \ 1 I I I <br />1 `1 i -- A <br />I AI _____ I <br />P i i i <br />I ! 1 GL I I I <br />` I 1 � I <br />Ll/I I o I <br />______J „ ______� � ______J <br />= <br />� <br />TOOL (1008.1.9.3.4) AND ARE OPERABLE WITH A SINGLE EFFORT OF THE DOOR LEVER. (1132A.8) <br />8. DOOR BUZZER, BELL, CHIME OR EQUIVALENT SHALL BE PROVIDED AT EVERY PRIMARY ENTRANCE <br />DOOR. (1132A.10) <br />9. THRESHOLD SECONDARY EXTERIOR DOORS OF DWELLING UNITS SHALL BE NO HIGHER THAN'/4 INCH <br />FOR SLIDING DOORS OR FOR OTHER DOORS. CHANGES IN HEIGHT BETWEEN'/4 AND 3/4 INCH SHALL <br />a <br />BE BEVELED AT A MAXIMUM 50 /o. (1008.1.7, 1132A.4.1) <br />10. ENTRANCE DOORS FROM INTERIOR CORRIDORS TOGETHER WITH THEIR PERIMETER SEALS SHALL <br />HAVE A LABORATORY STC RATING OF NOT LESS THAN 26. SUCH TESTED DOORS SHALL OPERATE <br />NORMALLY WITH COMMERCIALLY AVAILABLE SEALS UNLESS OTHERWISE REQUIRED BY AN <br />ACOUSTICAL REPORT. (1207.7) <br />11. DOORS ON AN ACCESSIBLE ROUTE SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE <br />HARDWARE, PANIC BARS, PUSH-PULL ACTIVATING BARS OR OTHER HARDWARE DESIGNED TO PROVIDE <br />PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP, TIGHT PINCHING OR TWISTING OF THE WRIST <br />A111 <br />TRASH VESTIBULE / CORRIDOR <br />B <br />T-0" <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />Al12 <br />CORRIDOR <br />B <br />3'-0" <br />PAIR <br />6-8"1 <br />3/4" <br />HM <br />SGP <br />HM <br />SGP <br />- <br />CONTROLLED ACCESS <br />Al 13 <br />CORRIDOR <br />B <br />T-0" <br />PAIR <br />6'-8" <br />1 3l4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />CONTROLLED ACCESS <br />0 <br />0 <br />LL <br />= <br />� <br />A401 <br />STAIR A4 ACCESS <br />B <br />3'-0" <br />6-8"1 <br />3l4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE <br />Al 14 <br />GARAGE / PUBLIC LOBBY <br />D <br />16'-0" <br />8'-0" <br />180 <br />CLOSES UPON FIRE ALARM ACTIVATION <br />A402 <br />UTILITY CLOSET <br />A <br />T-0" <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />Al 15 <br />GARAGE /PUBLIC LOBBY <br />B <br />T-0" <br />PAIR <br />6' 8" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />A403 <br />IDF /CORRIDOR <br />A <br />T-0" <br />PAIR <br />6' 8" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />Al 16 <br />PUBLIC LOBBY / LEASING <br />C <br />3-0 <br />PAIR <br />8'-0" <br />- <br />STEEL <br />FF <br />STEEL <br />FF <br />60 <br />CONTROLLED ACCESS <br />A404 <br />TRASH VESTIBULE <br />B <br />T-0" <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />Al 17 <br />PUBLIC LOBBY / RETAIL <br />C <br />T-0" <br />PAIR <br />8'-0" <br />STEEL <br />FF <br />STEEL <br />FF <br />60 <br />A405 <br />HVAC CLOSET <br />B <br />T-0" <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />A118 <br />RETAIL <br />C <br />3'-0" <br />PAIR <br />10'0" <br />AL <br />FF <br />AL <br />FF <br />DOOR TO REMAIN UNLOCKED DURING BUSINESS <br />HOURS <br />A406 <br />CORRIDOR FIRE WALL <br />E <br />T-0" <br />PAIR <br />6' 8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />180 <br />DUAL EGRESS, MAGNETIC HOLD OPEN, CLOSES <br />UPON FIRE ALARM ACTIVATION <br />A B C <br />FLUSH FLUSH WITH LIGHT STOREFRONT <br />O <br />TO OPERATE THE OPENING HARDWARE <br />12. LEVER -TYPE HARDWARE SHALL BE CURVED WITH A RETURN TO WITHIN''/2 INCH OF THE DOOR EXCEPT <br />IN GROUP R AND U OCCUPANCIES WITH AN OCCUPANT LOAD OF 10 OR LESS. <br />13. HARDWARE SHALL BE INSTALLED BETWEEN 34 MINIMUM TO 44 INCHES MAXIMUM ABOVE FINISHED <br />A119 <br />RETAIL <br />C <br />3'-0" <br />PAIR <br />10' 0" <br />AL <br />FF <br />AL <br />FF <br />DOOR TO REMAIN UNLOCKED DURING BUSINESS <br />HOURS <br />A407 <br />GARAGE /CORRIDOR <br />B <br />3' 0" <br />6' 8" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />180 <br />CONTROLLED ACCESS <br />A120 <br />LEASING <br />C <br />3-0 <br />PAIR <br />10'-0" <br />AL <br />FF <br />AL <br />FF <br />CONTROLLED ACCESS, PANIC HARDWARE <br />A408 <br />ELEVATOR 1 / CORRIDOR <br />E <br />T-6" <br />T-0" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />MAGNETIC HOLD OPEN, CLOSES UPON FIRE <br />ALARM ACTIVATION <br />SINGLE / PAIR SINGLE / PAIR SINGLE / PAIR <br />FLOOR. <br />14. EGRESS DOORS IN PAIRS, APPROVED AUTOMATIC FLUSH BOLTS SHALL BE PERMITTED PROVIDED <br />Al21 <br />FITNESS <br />A <br />3-0 <br />PAIR <br />6'-8" <br />I <br />13/4" <br />HM <br />I <br />SGP <br />HM <br />SGP <br />I <br />A409 <br />ELEVATOR 2 / CORRIDOR <br />E <br />T-6" <br />T-0" <br />I <br />13/4" <br />HM <br />SGP <br />I <br />HM <br />SGP <br />90 <br />MAGNETIC HOLD OPEN, CLOSES UPON FIRE <br />ALARM ACTIVATION <br />THAT THE DOOR LEAF HAVING THE AUTOMATIC FLUSH BOLTS HAS NO DOORKNOB OR SURFACE <br />MOUNTED HARDWARE. <br />A122 <br />STAIR A3 DISCHARGE <br />B <br />T-0" <br />8'-0" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />- <br />PANIC HARDWARE, CONTROLLED ACCESS <br />A410 <br />OF / CORRIDOR <br />A <br />3-0 <br />PAIR <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />----------------------i <br />15. EGRESS DOORS - MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT PERMITTED. <br />16. FIRE DOORS AND BOTH LEAVES OF PAIRS OF SIDE HINGED SWINGING FIRE DOORS SHALL BE <br />A123 <br />FITNESS / CORRIDOR <br />C <br />T-0" <br />8' 0" <br />- <br />STEEL <br />FF <br />STEEL <br />FF <br />60 <br />CONTROLLED ACCESS <br />A411 <br />STAIR A3 ACCESS <br />B <br />T-0" <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE <br />r--------------------� I MAGNETIC HOLD OPEN & DOOR CLOSER. <br />I I I I VERIFY DEPTH & ARM EXTENTIONS. INSTALL <br />SHIMS AS REQUIRED @ DOOR EDGE IS 90° TO <br />' FRAME WHEN DOOR IS HELD OPEN. <br />/ \ DOOR FACE TO BE FLUSH W/ FINISH @ <br />\ ADJACENT WALLS WHEN DOORS ARE IN THE <br />PROVIDED WITH AN ACTIVE LATCH BOLT THAT WILL SECURE THE DOOR WHEN IT IS CLOSED. <br />17. FIRE DOORS SHALL BE SELF -CLOSING OR AUTOMATIC CLOSING. AUTOMATIC -CLOSING FIRE DOORS <br />ASSEMBLIES SHALL BE SELF -CLOSING IN ACCORDANCE WITH NFPA 80 <br />18. SMOKE ACTIVATED DOORS - AUTOMATIC CLOSING DOORS SHALL CLOSE BY THE ACTUATION OF SMOKE <br />DETECTORS IN ACCORDANCE WITH SECTION 907.3 OR BY LOSS OF POWER. <br />19. INSTALL DOOR HARDWARE IN COMPLIANCE WITH MANUFACTURER'S INSTALLATION REQUIREMENTS. <br />A124 <br />STAIR A3 ACCESS <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />I <br />SGP <br />HM <br />SGP <br />I <br />90 <br />PANIC HARDWARE <br />A412 <br />CORRIDOR FIRE WALL <br />E <br />3-0 <br />PAIR <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />180 <br />DUAL EGRESS, MAGNETIC HOLD OPEN, CLOSES <br />UPON FIRE ALARM ACTIVATION <br />A125 <br />LOBBY / EXTERIOR <br />C <br />3-0 <br />PAIR <br />8'-0" <br />- <br />AL <br />FF <br />AL <br />FF <br />- <br />PANIC HARDWARE, CONTROLLED ACCESS <br />A413 <br />OF / CORRIDOR <br />A <br />2-6 <br />PAIR <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />A126 <br />LOBBY / LEASING <br />C <br />T-0" <br />8'-0" <br />- <br />STEEL <br />FF <br />STEEL <br />FF <br />60 <br />CONTROLLED ACCESS <br />A414 <br />STAIR A2 ACCESS <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE <br />OPEN POSITION. <br />20. PROTECT ALL THRESHOLDS COMPONENTS FROM DIRECT CONTACT WITH DISSIMILAR METALS AND <br />PANIC BARS @ PUSH SIDE OF DOOR RECESSED <br />&INTEGRAL WITH DOOR PROTRUDING MAX. 1/8" <br />\ / WHEN THE DOOR IS IN THE OPEN POSITION <br />LEVER HARDWARE ON HOLD OPEN SIDE OF <br />DOOR. <br />D E <br />CORROSIVE MATERIALS PER MANUFACTURER'S RECOMMENDATIONS. <br />21. DOORS ON AN ACCESSIBLE ROUTE: THE BOTTOM 10 INCHES MINIMUM OF ALL DOORS AND OR GATES <br />SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR OR GATE TO BE OPENED BY <br />A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. <br />22. GLAZING IN DOORS SHALL COMPLY WITH SAFETY GLAZING (2406) RATINGS <br />23. FIRE DOOR ASSEMBLIES THAT ARE SIDE HINGED OR PIVOTED SWINGING SHALL BE TESTED IN <br />ACCORDANCE WITH NFPA 252 OR UL 10C. <br />24. FIRE DOOR ASSEMBLIES WITH OTHER TYPES OF DOORS INCLUDING SWINGING ELEVATOR DOORS AND <br />A127 <br />CORRIDOR FIRE WALL <br />E <br />3 <br />PAIR <br />6'-8" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />180 <br />UPON FIRE ALARM ACTIVATION DUAL EGRESS, MAGNETIC HOLD OPEN, CLOSES <br />A415 <br />STAIR A2 ACCESS <br />B <br />T-0" <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />180 <br />PANIC HARDWARE <br />Al28 <br />GARAGE / PARCEL ROOM <br />A <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />A416 <br />STAIR Al ACCESS <br />B <br />T-0" <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE, CONTROLLED ACCESS INTO <br />GARAGE <br />A129 <br />CORRIDOR FIRE WALL <br />E <br />3'-0" <br />PAIR <br />6'-8" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />180 <br />DUAL EGRESS, MAGNETIC HOLD OPEN, CLOSES <br />UPON FIRE ALARM ACTIVATION <br />A130 <br />ELECTRICAL ROOM / CORRIDOR <br />A <br />T-0" <br />6'-8" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />PANIC HARDWARE <br />OVERHEAD COILING DOOR FIRE DOOR <br />FIRE SHUTTER ASSEMBLIES SHALL BE TESTED IN ACCORDANCE WITH NFPA 252 OR UL10B <br />SINGLE / PAIR <br />Al31 <br />ELECTRICAL ROOM / EXTERIOR <br />A <br />4'4" <br />8'-0" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />- <br />PANIC HARDWARE <br />A501 <br />STAIR A4 ACCESS <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE <br />25. FIRE DOOR ASSEMBLIES REQUIRED TO HAVE A MINIMUM FIRE PROTECTION RATING OF 20 MINUTES <br />0 <br />O <br />U_ <br />WHERE LOCATED IN A CORRIDOR OR SMOKE BARRIER WALLS HAVING A FIRE RESISTANCE RATING IN <br />ACCORDANCE WITH TABLE 715.4 SHALL BE TESTED IN ACCORDANCE WITH NFPA 252 OR UL 10C <br />WITHOUT THE HOSE STREAM TEST. <br />26. SMOKE AND DRAFT CONTROL - FIRE DOOR ASSEMBLIES REQUIRED TO HAVE A MINIMUM FIRE <br />PROTECTION RATING OF 20 MINUTES WHERE LOCATED IN A CORRIDOR OR SMOKE BARRIER WALLS <br />A132 <br />OF / CORRIDOR <br />A <br />2 <br />PAIR <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />A502 <br />UTILITY CLOSET <br />A <br />T-0" <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />A133 <br />STAIR A2 ACCESS <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE <br />A503 <br />OF / CORRIDOR <br />A <br />3 PAIR <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />o <br />A134 <br />STAIR A2 ACCESS <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />180 <br />PANIC HARDWARE <br />U_ <br />A504 <br />TRASH VESTIBULE <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />SHALL MEET THE REQUIREMENTS FOR SMOKE AND DRAFT CONTROL DOOR ASSEMBLIES TESTED IN <br />ACCORDANCE WITH UL 1784 <br />27. GLAZING IN DOOR ASSEMBLY - IN 20 MINUTE FIRE DOOR ASSEMBLY, THE GLAZING MATERIAL IN THE <br />DOOR ITSELF SHALL HAVE A MINIMUM FIRE -PROTECTION -RATED -GLAZING OF 20 MINUTES. <br />28. FIRE DOOR ASSEMBLIES IN EXIT ENCLOSURES AND EXIT PASSAGE WAYS SHALL HAVE A MAXIMUM <br />TRANSMITTED TEMPERATURE END POINT OF NOT MORE THAN 450 F DEGREES. THIS IS NOT REQUIRED <br />WHEN BUILDING IS EQUIPPED THROUGHOUT WITH AN NFPA 13 AUTOMATIC SPRINKLER SYSTEM. <br />29• DOOR FRAMES WITH TRANSOM LIGHTS, SIDELIGHTS OR BOTH, SHALL BE PERMITTED WHERE A'/4 HOUR <br />FIRE PROTECTION RATING OR LESS IS REQUIRED. WHERE A FIRE PROTECTION RATING EXCEEDING'/ <br />HOUR IS REQUIRED FIRE DOOR FRAMES WITH TRANSOM LIGHTS, SIDELIGHTS OR BOTH SHALL BE <br />Al35 <br />STAIR A2 DISCHARGE <br />B <br />T-0" <br />8'-0" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />PANIC HARDWARE, CONTROLLED ACCESS <br />A505 <br />ELECTRICAL CLOSET <br />A <br />T-0" <br />PAIR <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />A136 <br />GARAGE <br />D <br />20'-0" <br />9'-0" <br />- <br />- <br />CONTROLLED ACCESS <br />A506 <br />ELECTRICAL CLOSET <br />A <br />T-0" <br />PAIR <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />A137 <br />FIRE PUMP ROOM / GARAGE <br />A <br />T-0" <br />PAIR <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />A507 <br />ELECTRICAL CLOSET <br />A <br />T-0" <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />A138 <br />BOOSTER PUMP ROOM / GARAGE <br />A <br />3' 0" <br />PAIR <br />6-8"1 <br />3/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />A508 <br />CORRIDOR FIRE WALL <br />E <br />3' 0" <br />PAIR <br />6-8"1 <br />3/4" <br />HM <br />SGP <br />HM <br />SGP <br />180 <br />DUAL EGRESS, MAGNETIC HOLD OPEN, CLOSES <br />UPON FIRE ALARM ACTIVATION <br />A139 <br />GARAGE <br />B <br />T-0" <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />- <br />PANIC HARDWARE, CONTROLLED ACCESS <br />A509 <br />GARAGE / CORRIDOR <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />180 <br />CONTROLLED ACCESS <br />INSTALLED WITH FIRE -RESISTANCE -RATED GLAZING TESTED AS AN ASSEMBLY IN ACCORDANCE WITH <br />ASTM E119 OR UL 263. <br />30. DOORS THAT ARE PART OF A FIRE RATED WALL ASSEMBLY SHALL COMPLY WITH OPENING <br />A140 <br />BIKE ROOM / GARAGE <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />CONTROLLED ACCESS <br />A510 <br />ELEVATOR 1 / CORRIDOR <br />E <br />T-6" <br />T-0" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />MAGNETIC HOLD OPEN, CLOSES UPON FIRE <br />ALARM ACTIVATION <br />F G <br />PROTECTIVES. <br />LABELS <br />A141 <br />GARAGE <br />D <br />23'-0" <br />9'-0" <br />CONTROLLED ACCESS <br />A511 <br />ELEVATOR 2 / CORRIDOR <br />E <br />T-6" <br />T-0" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />MAGNETIC HOLD OPEN, CLOSES UPON FIRE <br />ALARM ACTIVATION <br />GATE LOUVERED DOOR <br />31. FIRED OORA SSEMBLIES SHALL BE LABELED BY AN APPROVED AGENCY. THE LABELS SHALL COMPLY <br />WITH NFPA 80 AND SHALL BE PERMANENTLY AFFIXED TO THE DOOR OR FRAME. <br />A142 <br />GARAGE <br />F <br />T-0" <br />6'-8" <br />- <br />PANIC HARDWARE, CONTROLLED ACCESS <br />A512 <br />OF / CORRIDOR <br />A <br />T-O" <br />PAIR <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />32. FIRE DOORS SHALL BE LABELED SHOWING THE NAME OF THE MANUFACTURER, THE NAME OR <br />A143 <br />STAIR Al ACCESS <br />B <br />T-0" <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE <br />A513 <br />STAIR A3 ACCESS <br />B <br />3' 0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE <br />TRADEMARK OF THE THIRD -PARTY INSPECTION AGENCY, THE FIRE PROTECTION RATING AND WHERE <br />REQUIRED FOR FIRE DOORS IN EXIT ENCLOSURES AND EXIT PASSAGEWAYS THE MAXIMUM <br />TRANSMITTED TEMPERATURE END POINT. LABELS SHALL BE APPROVED AND PERMANENTLY AFFIXED <br />A144 <br />STAIR Al DISCHARGE <br />B <br />3' 0" <br />8' 0" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />PANIC HARDWARE, CONTROLLED ACCESS INTO <br />STAIR FROM EXTERIOR <br />A514 <br />CORRIDOR FIRE WALL <br />E <br />T-0" <br />PAIR <br />6' 8" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />180 <br />DUAL EGRESS, MAGNETIC HOLD OPEN, CLOSES <br />UPON FIRE ALARM ACTIVATION <br />AND FACTORY APPLIED. SMOKE AND DRAFT CONTROL DOORS COMPLYING WITH UL 1784 SHALL SHOW <br />THE LETTER "S" ON THE FIRE RATED LABEL. <br />A515 <br />OF /CORRIDOR <br />A <br />2'-6 <br />PAIR <br />6' 8" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />33. OVERSIZED FIRE DOORS SHALL BEAR AN OVERSIZED FIRE DOOR LABEL BY AN APPROVED AGENCY OR <br />A516 <br />STAIR A2 ACCESS <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE <br />SHALL BE PROVIDED WITH A CERTIFICATE OF INSPECTION BY AN APPROVED TESTING AGENCY. <br />34. FIRE DOOR FRAMES SHALL BE LABELED SHOWING THE NAME OF THE MANUFACTURER AND THE <br />A201 <br />STAIR A4 ACCESS <br />B <br />3'-0" <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE <br />A517 <br />STAIR A2 ACCESS <br />B <br />3' 0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />180 <br />PANIC HARDWARE <br />THIRD -PARTY INSPECTION AGENCY. <br />O <br />O <br />J <br />35. GLAZING - FIRE -PROTECTION- RATED GLAZING SHALL BEAR A LABEL OR OTHER IDENTIFICATION <br />SHOWING THE NAME OF THE MANUFACTURER, THE TEST STANDARD AND THE FOLLOWING FOUR PART <br />IDENTIFICATION ISSUED BY AN APPROVED AGENCY AND PERMANENTLY AFFIXED TO THE GLAZING. <br />THE LABEL SHALL BEAR THE FOLLOWING FOUR PART IDENTIFICATION: <br />A202 <br />UTILITY CLOSET <br />A <br />3' 0" <br />6' 8" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />A203 <br />POOL EQUIPMENT <br />A <br />3' 0" <br />6' 8" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />LL 0 <br />z <br />0 <br />0 <br />w <br />"D- HORNH -TORNT-XXX" <br />D INDICATES THE GLAZING SHALL BE USED IN FIRE DOORS PER NFPA 252 <br />H OR NH INDICATES THE GLAZING MEETS OR DOES NOT MEET THE HOSE STREAM TEST <br />T OR NT INDICATES THE GLAZING MEETS OR DOES NOT MEET THE TEMPERATURE REQUIREMENTS <br />XXX INDICATES THE FIRE -PROTECTION -RATING PERIOD IN MINUTES. <br />36. EXTERIOR DOORS SHALL BE INSTALLED BEARING MANUFACTURER'S CERTIFICATE OF COMPLIANCE <br />WITH SPECIFIED THERMAL AND ACOUSTICAL REQUIREMENTS. <br />WEATHERIZATION <br />37. DOORS SHALL HAVE ALL SIX SIDES FACTORY PRIMED OR SEALED AFTER HARDWARE PREPARATION. <br />RESEAL ALL SURFACES IMMEDIATELY AFTER INSTALLATION. <br />A204 <br />TRASH VESTIBULE <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />0 <br />O <br />U_ <br />= <br />x <br />A601 <br />STAIR A4 ACCESS <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE <br />A205 <br />STORAGE ROOM <br />B <br />3' 0" <br />6' 8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />CONTROLLED ACCESS <br />A602 <br />UTILITY CLOSET <br />A <br />3' 0" <br />6' 8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />A206 <br />STORAGE CLOSETS <br />A <br />3'-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />- <br />DOOR OCCURS MULTIPLE TIMES <br />1 <br />A603 <br />OF / CORRIDOR <br />A <br />3-0 <br />PAIR <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />A207 <br />STORAGE ROOM <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />CONTROLLED ACCESS <br />A604 <br />TRASH VESTIBULE <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />A208 <br />CORRIDOR <br />B <br />3'-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />CONTROLLED ACCESS <br />A605 <br />CORRIDOR FIRE WALL <br />E <br />3'-0" <br />PAIR <br />6'-8" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />180 <br />DUAL EGRESS, MAGNETIC HOLD OPEN, CLOSES <br />I UPON FIRE ALARM ACTIVATION <br />A209 <br />BREAK ROOM <br />B <br />3'-0" <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />- <br />W <br />A606 <br />STORAGE <br />A <br />3-0 <br />PAIR <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />38. EXTERIOR DOORS SHALL BE INSULATED AND FULLY WEATHER STRIPPED. <br />39. REFER TO REFERENCED DETAILS OF EXTERIOR DOORS FOR INTEGRATION WITH EXTERIOR WALL AND <br />A210 <br />MAINTENANCE <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />A607 <br />ELEVATOR 1 / CORRIDOR <br />E <br />T-6" <br />T-0" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />MAGNETIC HOLD OPEN, CLOSES UPON FIRE <br />ALARM ACTIVATION <br />THRESHOLD FLASHING SYSTEMS. <br />40. INSULATE SHIM CAVITY AROUND EXTERIOR DOORS WITH LOW EXPANSION FOAM. <br />A211 <br />COMMON OPS <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />A608 <br />ELEVATOR 2 / CORRIDOR <br />E <br />T-6" <br />T-0" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />MAGNETIC HOLD OPEN, CLOSES UPON FIRE <br />ALARM ACTIVATION <br />41. FOR DOOR/ FRAME ASSEMBLIES IN C.M.U. VERIFY MASONRY OPENING DIMENSIONS. <br />42. PROVIDE SEPARATION BY A TIGHT FITTING DOOR BETWEEN FOOD PREPARATION AREA(S) (INCLUDING <br />A212 <br />SHARED GOODS <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />A609 <br />OF / CORRIDOR <br />A <br />3 0 <br />PAIR <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />FOOD STORAGE ROOMS) AND TOILET ROOM(S). SECTION 302.6 <br />A213 <br />GARAGE / CORRIDOR <br />B <br />T-0" <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />180 <br />CONTROLLED ACCESS <br />A610 <br />STAIR A3 ACCESS <br />B <br />3'-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE <br />A214 <br />ELEVATOR 1 / CORRIDOR <br />E <br />T-6" <br />T-0" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />MAGNETIC HOLD OPEN, CLOSES UPON FIRE <br />ALARM ACTIVATION <br />A215 <br />ELEVATOR 2 / CORRIDOR <br />E <br />T-6" <br />7'-0" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />MAGNETIC HOLD OPEN, CLOSES UPON FIRE <br />ALARM ACTIVATION <br />GLAZING PERFORMANCE <br />A216 <br />OF /CORRIDOR <br />A <br />PAIR <br />6-8" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />� <br />A701 <br />ROOF DECK <br />C <br />3'-0" <br />6-8" <br />13/4" <br />AL <br />FF <br />AL <br />FF <br />- <br />CONTROLLED ACCESS <br />0 <br />GLAZING LOCATION <br />U VALUE <br />SHGC <br />A217 <br />YOGA STUDIO <br />C <br />T-0" <br />6'-8" <br />- <br />STEEL <br />FF <br />STEEL <br />FF <br />60 <br />CONTROLLED ACCESS, PANIC HARDWARE <br />A702 <br />STAIR A4 ACCESS <br />A <br />3'-0" <br />6'4" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />O <br />A218 <br />STAIR A3 ACCESS <br />B <br />3'-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE <br />LL <br />I.- <br />z <br />LJ,J <br />i <br />LLI <br />A703 <br />STAIR A4 ACCESS <br />B <br />3'-0" <br />6'-8" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE <br />EXTERIOR DOORS <br />45 <br />.23 <br />A219 <br />CORRIDOR FIRE WALL <br />E <br />3'-0" <br />PAIR <br />6-8"1 <br />3l4" <br />HM <br />SGP <br />HM <br />SGP <br />180 <br />DUAL EGRESS, MAGNETIC HOLD OPEN, CLOSES <br />UPON FIRE ALARM ACTIVATION <br />A704 <br />UTILITY CLOSET <br />A <br />3'-0" <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />BLDG A STOREFRONT <br />.46 <br />.22 <br />A220 <br />CORRIDOR FIRE WALL <br />E <br />3-0 <br />PAIR <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />180 <br />DUAL EGRESS, MAGNETIC HOLD OPEN, CLOSES <br />UPON FIRE ALARM ACTIVATION <br />A705 <br />IDF / CORRIDOR <br />A <br />3-01. <br />PAIR <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />A221 <br />IDF/CORRIDOR <br />A <br />2-6 <br />PAIR <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />A706 <br />TRASH VESTIBULE <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />BLDG B STOREFRONT <br />46 <br />.22 <br />A222 <br />STAIR A2 ACCESS <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE <br />A707 <br />CORRIDOR FIRE WALL <br />E <br />3 <br />PAIR <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />180 <br />DUAL EGRESS, MAGNETIC HOLD OPEN, CLOSES <br />UPON FIRE ALARM ACTIVATION <br />U) <br />A223 <br />STAIR Al ACCESS <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANICHARDWARE, CONTROLLED ACCESS INTO <br />A708 <br />STORAGE <br />A <br />PAIR <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />DOOR STC RATINGS <br />A709 <br />ELEVATOR 1 / CORRIDOR <br />E <br />T-6" <br />T-0" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />MAGNETIC HOLD OPEN, CLOSES UPON FIRE <br />ALARM ACTIVATION <br />A710 <br />ELEVATOR 2 / CORRIDOR <br />E <br />T-6" <br />T-0" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />MAGNETIC HOLD OPEN, CLOSES UPON FIRE <br />ALARM ACTIVATION <br />LIVING UNIT ENTRY DOORS AND PATIO DOORS SHALL BE SOUND -RATED, PROVIDING A MINIMUM <br />STC RATING WHEN IN THE CLOSED POSITION. IN ACCORDANCE WITH THE ACOUSTICAL REPORT. <br />0 <br />O <br />LL <br />A301 <br />STAIR A4 ACCESS <br />B <br />3'-0" <br />8'-0" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE <br />A711 <br />OF / CORRIDOR <br />A <br />3-0 <br />PAIR <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />TYPICALDOOR OPENINGS <br />A302 <br />STAIR A4 ACCESS <br />B <br />3'-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE <br />A712 <br />STAIR A3 ACCESS <br />B <br />T-0" <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />PANIC HARDWARE <br />A303 <br />UTILITY CLOSET <br />A <br />3'-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />DOOR ABBREVIATIONS <br />2-HR 1-HR <br />A304 <br />OF /CORRIDOR <br />A <br />PAIR <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />X <br />X X <br />AD-XX AD-XX AD-XX / \ <br />El El <br />X <br />AD XX / \ <br />/ AD XX TEMP TEMP <br />= <br />A305 <br />TRASH VESTIBULE <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />AL ALUMINUM P PAINT <br />AN ANODIZED PASS PASSAGE <br />AUTO AUTOMATIC CLOSING PB PUSH BUTTON <br />ECA ELECTRONIC CONTROL ACCESS PFSF PRE -FINISHED STEEL FRAME <br />F FACTORY PH PANIC HARDWARE <br />FGL FIBERGLASS PR PAIR <br />FF FACTORY FINISH PRIV PRIVACY LOCK <br />FX FIXED S STAIN <br />A306 <br />CLUBHOUSE <br />B <br />T-0" <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />PANIC HARDWARE, CONTROLLED ACCESS <br />A307 <br />ELECTRICAL CLOSET <br />A <br />T-0 <br />PAIR <br />6' 8" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />A308 <br />ELECTRICAL CLOSET <br />A <br />PAIR <br />6'-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />- r GL GL / <br />X L------J L------J <br />AD-XX X / <br />X AD-XX �` / <br />AD-XX V i <br />A309 <br />ELECTRICAL CLOSET <br />A <br />3'-0" <br />6'-8" <br />13/4'. <br />HM <br />SGP <br />HM <br />SGP <br />60 <br />FR FRENCH DOOR SC SOLID CORE <br />GL GLASS SELF SELF CLOSING <br />HC HOLLOW CORE SG SEMI -GLOSS PAINT <br />HM HOLLOW METAL STRF STORE FRONT <br />MA MASONITE TG TEMPERED GLASS <br />A310 <br />CORRIDOR FIRE WALL <br />E <br />3-0 <br />PAIR <br />6'-8" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />180 <br />DUAL EGRESS, MAGNETIC HOLD OPEN, CLOSES <br />UPON FIRE ALARM ACTIVATION <br />A311 <br />WOMENS RESTROOM <br />G <br />3'-0" <br />8'-0" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />UNIT FIRE DOOR X STOREFRONT <br />DOOR AD XX DOOR <br />MC MINERAL CORE TS TUBE STEEL <br />MTL METAL WD WOOD <br />N/R NON -RATED <br />OCG OVERHEAD COILING GRILLE <br />A312 <br />JANITOR CLOSET <br />G <br />3'-0" <br />8'-0" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />A313 <br />MENS RESTROOM <br />G <br />3'-0" <br />8'-0" <br />1 3/4" <br />HM <br />SGP <br />HM <br />SGP <br />OCD OVERHEAD COILING DOOR <br />A314 <br />GARAGE / CORRIDOR <br />B <br />T-0" <br />6-8" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />180 <br />CONTROLLED ACCESS <br />A315 <br />ELEVATOR 1 / CORRIDOR <br />E <br />T-6" <br />7'-0" <br />13/4" <br />HM <br />SGP <br />HM <br />SGP <br />90 <br />MAGNETIC HOLD OPEN, CLOSES UPON FIRE <br />ALARM ACTIVATION <br />Architecture + Planning <br />17911 Von Karman Ave. <br />Suite 200 <br />Irvine, CA 92614 <br />ktgy.com <br />949.851.2133 <br />KTGY Project No: 2017-0934 <br />Project Contact: Debbie Holland <br />Email: dholland@ktgy.com <br />Principal: Wil Wong <br />Project Designer: D. Schoolmeester <br />Project Director: Debbie Holland <br />Developer <br />ED OAK <br />INV STNAEN I'S <br />4199 CAMPUS DRIVE <br />IRVINE, CA 92612 <br />PHONE NO. (714) 342-2502 <br />O <br />N <br />Q <br />U <br />Q <br />z <br />Q <br />Q <br />z <br />a <br />U) <br />LU <br />U) <br />w <br />LO <br />LO <br />06 <br />r <br />It <br />No. Date Description <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />D ARcy'lTF <br />io <br />NJDATE <br />REAUG�Q- <br />OF C A� <br />License Stamp <br />BUILDING A DOOR <br />SCHEDULE <br />BUILDING <br />A A7-1 <br />N <br />C) <br />N <br />1 <br />r <br />C) <br />00 <br />C) <br />COPYRIGHT (2) <br />