Laserfiche WebLink
ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIGHTS SHALL COMPLY WITH CBC SECTION <br />GRAB BARS SHALL COMPLY WITH CBC SECTION 1127A.4 <br />LAVATORIES, VANITIES, MIRRORS AND TOWEL FIXTURES SHALL COMPLY WITH CBC SECTION <br />WATER CLOSETS IN BATHROOMS AND POWDER ROOMS SHALL COMPLY WITH CBC SECTION <br />BATHTUBS REQUIRED TO BE ACCESSIBLE SHALL COMPLY WITH CBC SECTION 1134A.5 <br />THIS SHEET IS FOR REFERENCE ONLY AND ILLUSTRATES CODE -REQUIRED MINIMUM STANDARDS FOR DWELLING <br />1136A <br />1134A.8. WHEN TWO OR MORE LAVATORIES ARE PROVIDED, AT LEAST ONE SHALL BE <br />1134.A.7. <br />UNITS WITHIN A MULTIFAMILY DEVELOPMENT. SEE PERTINENT SHEETS, DRAWINGS, AND SPECIFICATIONS FOR <br />A. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, 33" MINIMUM AND 36" MAXIMUM <br />ACCESSIBLE. <br />A. THERE SHALL BE A MINIMUM FLOOR SPACE 48" PARALLEL BY 30" PERPENDICULAR TO THE <br />APPLICATION OF THESE STANDARDS TO THIS SPECIFIC PROJECT. <br />A. ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES OR LESS AND <br />ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE. <br />A. THE MINIMUM FLOOR SPACE PROVIDED AT A WATER CLOSET SHALL BE 48" IN CLEAR WIDTH. <br />SIDE OF THE BATHTUB OR BATHTUB -SHOWER COMBINATION MEASURED FROM THE FOOT OR <br />THE INFORMATION CONTAINED WITHIN THESE SHEETS ARE EXCERPTS FROM THE 2019 CALIFORNIA BUILDING CODE <br />COMMUNICATION SYSTEM RECEPTACLES SHALL BE LOCATED NO MORE THAN 48" MEASURED <br />EXCEPTION THAT THE HEIGHT OF THE LOWER GRAB BAR ON THE BACK WALL OF A BATHTUB <br />A. LOCATION: THE LAVATORY SHALL BE LOCATED WITH THE CENTERLINE OF THE FIXTURE A <br />THE CLEAR FLOOR SPACE SHALL EXTEND PAST THE FRONT EDGE OF THE WATER CLOSET AT <br />DRAIN END OF THE TUB. THE AREA UNDER A LAVATORY MAY BE INCLUDED IN THE CLEAR <br />(CBC) AND APRIL 1998 FAIR HOUSING ACT (FHA) DESIGN MANUAL, AND INTENDED TO PROVIDED THE CONTRACTOR <br />FROM THE TOP OF THE RECEPTACLE OUTLET BOX NOR LESS THAN 15" TO THE BOTTOM OF <br />SHALL COMPLY WITH SECTION 1127A.5.2. <br />MINIMUM OF 18" FROM AN ADJOINING WALL OR FIXTURE FOR FORWARD APPROACH. THE <br />LEAST 36". <br />FLOOR SPACE PROVIDED THAT KNEE AND TOE SPACE COMPLY WITH SECTION 1134A.8 (SEE <br />THE GENERAL REQUIREMENTS OF ACCESSIBILITY FOR THIS PROJECT. THE GENERAL CONTRACTOR SHALL BE <br />THE RECEPTACLE OUTLET BOX TO THE LEVEL OF THE FINISHED FLOOR OR WORKING <br />B. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB BAR SHALL COMPLY WITH <br />LAVATORY SHALL BE LOCATED WITH THE CENTERLINE OF THE FIXTURE A MINIMUM OF 24" <br />EXCEPTION: THE 48" MINIMUM CLEAR WIDTH MAY BE REDUCED TO 36" FOR LAVATORIES, <br />DETAIL 16 THIS SHEET). CABINETS UNDER LAVATORIES AND TOILETS SHALL NOT ENCROACH <br />KNOWLEDGEABLE OF AND SHALL BUILD TO ALL APPLICABLE ACCESSIBILITY CODE REQUIREMENTS, IF FURTHER <br />PLATFORM. IF THE REACH IS OVER A PHYSICAL BARRIER OR AN OBSTRUCTION (FOR EXAMPLE <br />THE FOLLOWING: <br />FROM AN ADJOINING WALL OR FIXTURE FOR PARALLEL APPROACH. THE TOP OF THE <br />CABINETS, WING WALLS OR PRIVACY WALLS LOCATED IMMEDIATELY ADJACENT TO A <br />INTO THE FLOOR SPACE. <br />INFORMATION OR CLARIFICATION IS REQUIRED, CONSULT THE ARCHITECT OR REFERENCE THE CBC AND FHA <br />A KITCHEN BASE CABINET), RECEPTACLES SHALL BE LOCATED WITHIN THE REACH RANGES <br />1. GRAB BARS WITH CIRCULAR CROSS SECTION SHALL HAVE AN OUTSIDE DIAMETER OF 1 n". <br />FIXTURE RIM SHALL BE A MAXIMUM OF 34 " ABOVE THE FINISH FLOOR. DISTANCE SHALL BE <br />WATER CLOSET WHICH EXTEND NO MORE THAN 24" IN DEPTH. <br />B. GRAB BAR REINFORCEMENT SHALL BE PROVIDED ON THE BACK AND SIDE SURROUNDING <br />DESIGN MANUAL PRIOR TO FABRICATION OR INSTALLATION OF THE WORK. <br />SPECIFIED IN SECTION 1138A.3. PHYSICAL BARRIERS AND OBSTRUCTIONS SHALL NOT EXTEND <br />2. GRAB BARS WITH NON -CIRCULAR CROSS SECTION SHALL HAVE ACROSS- SECTION <br />MEASURED TO THE HIGHER OF THE FIXTURE RIM FOR SURFACE MOUNT OR COUNTER <br />WATER CLOSETS SHALL BE LOCATED WITHIN BATHROOMS IN A MANNER THAT PERMITS A <br />WALLS AS SHOWN BELOW. IA BATHTUB INSTALLED WITHOUT SURROUNDING WALLS SHALL <br />DWELLING UNITS SHALL COMPLY WITH CBC CHAPTER 11A AND THE FHA DESIGN MANUAL. A DWELLING UNIT IS A <br />MORE THAN 25 INCHES FROM THE WALL BENEATH THE RECEPTACLE. <br />DIMENSION OF 2" MAXIMUM. THE PERIMETER DIMENSION OF GRAB BARS WITH NON -CIRCULAR <br />SURFACE FOR UNDER MOUNT. <br />GRAB BAR TO BE INSTALLED ON ONE SIDE OF A FIXTURE. IN LOCATIONS WHERE WATER <br />PROVIDE REINFORCED AREAS FOR INSTALLATION OF FLOOR -MOUNTED GRAB BARS. <br />SINGLE UNIT OF RESIDENCE FOR A FAMILY OF ONE OR MORE PERSONS, WHICH MAY INCLUDE CONDOMINIUMS, AN <br />CROSS SECTION SHALL BE 4" MINIMUM AND AND 4.8" MAXIMUM. <br />" " B. MANEUVERING: A 30X 48CLEAR SPACE SHALL BE CENTERED ON THE LAVATORY. <br />CLOSETS ARE ADJACENT TO WALLS VANITIES LAVATORIES OR BATHTUBS THE CENTERLINE <br />C. FAUCET CONTROLS AND OPERATION MECHANISMS SHALL BE OPERABLE WITH ONE HAND <br />APARTMENT UNIT WITHIN AN APARTMENT BUILDING, AND OTHER TYPES OF DWELLINGS IN WHICH SLEEPING <br />RECEPTACLE OUTLETS THAT DO NOT SATISFY THESE SPECIFICATIONS ARE ACCEPTABLE <br />3. L-SHAPED OR U-SHAPED GRAB BARS SHALL BE PERMITTED. <br />OF THE FIXTURE SHALL BE A MINIMUM OF 18" FROM THE OBSTACLE. <br />AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE <br />ACCOMMODATIONS ARE PROVIDED BUT TOILETING OR COOKING FACILITIES ARE SHARED BY OCCUPANTS OF MORE <br />PROVIDED THAT COMPARABLE RECEPTACLE OUTLETS, THAT PERFORM THE SAME FUNCTIONS, <br />C. THE SECURED STRENGTH OF GRAB BARS, TUB AND SHOWER SEATS, FASTENERS AND <br />MANEUVERING SPACE <br />B. WATER CLOSETS SHALL BE LOCATED IN A FLOOR SPACE MIN. 48" IN WIDTH AND MIN. 66" IN <br />FORCE TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUND -FORCE. LEVER <br />THAN ONE ROOM OR PORTION OF THE DWELLING. EXAMPLES OF THE LATTER INCLUDE DORMITORY ROOMS AND <br />ARE PROVIDED WITHIN THE SAME AREA AND ARE ACCESSIBLE. <br />MOUNTING DEVICES SHALL MEET THE REQUIREMENTS WITHIN SECTION 1127A.4.4. GRAB BARS <br />__ _ _ __ <br />DEPTH. A FIXED CABINET OR WING WALL MAY PROJECT MAX. 24" PERPENDICULAR FROM THE <br />OPERATED, PUSH -TYPE, AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES <br />SLEEPING ACCOMMODATIONS IN SHELTERS INTENDED FOR OCCUPANCY SUCH AS RESIDENCES FOR HOMELESS <br />PERSONS. <br />SHALL NOT ROTATE WITHIN THEIR FITTINGS. <br />J <br />REAR WALL OF THE FIXTURE (FHA 7.43-7.44). <br />OF ACCEPTABLE DESIGNS. <br />GENERAL NOTES <br />1 <br />EXCEPTIONS INCLUDE OUTLETS INSTALLED FOR BASEBOARD HEATERS, FLOOR RECEPTACLES <br />INSTALLED ADJACENT TO SLIDING PANELS OR WALLS, BASEBOARD OUTLETS USED IN <br />D. A GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT TO IT SHALL BE FREE OF ANY <br />SHARP OR ABRASIVE ELEMENTS AND SHALL HAVE ROUND EDGES. <br />Ii <br />i I <br />-'I <br />C. WATER CLOSET SEAT HEIGHT SHALL BE MIN. 15". <br />D. CONTROLS SHALL SHALL BE MOUNTED NO MORE THAN 44" ABOVE THE FLOOR. THE FORCE <br />RELOCATABLE PARTITIONS, WINDOW WALLS OR OTHER ELECTRICAL CONVENIENCE FLOOR <br />I I i Z Q <br />I I 2 <br />REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUND -FORCE <br />24" MIN. <br />OUTLETS NOT SUBJECT TO THE MINIMUM HEIGHT REQUIREMENTS. <br />= I w <br />z Q <br />� U <br />E. GRAB BAR REINFORCEMENT SHALL BE PROVIDED AS SHOWN BELOW. <br />LOCATED AT BOTH HEAD <br />I �� o <br />ACCESSIBLE ROUTE(S) WITHIN COVERED MULTIFAMILY DWELLING UNITS SHALL COMPLY WITH <br />B. CONTROLS OR SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR AREA <br />FACE OF FINISH <br />- - <br />_ �� �� Q <br />WALL AND CONTROL WALL <br />SECTION 1130A. <br />TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES, ALARMS OR COOLING, <br />v Q I ��' J U = <br />A. AN ACCESSIBLE ROUTE SHALL BE PROVIDED THROUGH ALL ROOMS AND SPACES OF THE <br />HEATING AND VENTILATING EQUIPMENT SHALL BE LOCATED NO MORE THAN 48" MEASURED TO <br />1 1" CIRCULAR DIAMETER OF 1 �" <br />4 <br />J I I 2 O Q � Q Q <br />1 I <br />40" MIN. 12" 26" MIN. <br />DWELLING UNIT. THE ACCESSIBLE ROUTE SHALL PASS THROUGH THE PRIMARY ENTRY DOOR, <br />THE TOP OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING NOR LESS THAN 15" TO <br />2 <br />MINIMUM TO 2" MAXIMUM. <br />w �� z w O J p <br />J I I I 0 ? Q Q 0 <br />< <br />�- �- - <br />MAX. <br />AND SHALL CONNECT WITH ALL ADDITIONAL EXTERIOR DOORS, REQUIRED CLEAR FLOOR SPACES <br />THE BOTTOM OF THE RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING TO THE LEVEL OF <br />IN <br />a - - ---- - --------y 0 w Of <br />I 0 APPROACH - Q 0 w Q a <br />z J <br />AT KITCHEN APPLIANCES AND BATHROOM FIXTURES. <br />THE FINISHED FLOOR OR WORKING PLATFORM. IF THE REACH IS OVER AN OBSTRUCTION (FOR <br />- <br />a 1 `_9' Q Q N U w Q <br />2 ¢ <br />B. THE ACCESSIBLE ROUTES INTO AND THROUGHOUT COVERED MULTIFAMILY DWELLING UNITS MAY <br />EXAMPLE A KITCHEN BASE CABINET) SWITCHES AND CONTROLS SHALL BE LOCATED WITHIN <br />---- - -- -� LU <br />GRAB BAR GRAB AR <br />0o 2 Y <br />INCLUDE HALLWAYS, CORRIDORS AND RAMPS AND SHALL BE AT LEAST 36" WIDE. <br />THE REACH RANGES SPECIFIED IN SECTION 1138A.3. PHYSICAL BARRIERS OR OBSTRUCTIONS <br />w <br />U <br />REINFORCEMENT REINFOR EMENT <br />M M Q <br />SHALL NOT EXTEND MORE THAN 25" FROM THE WALL BENEATH A CONTROL. <br />0° <br />CHANGES IN LEVEL ON ACCESSIBLE ROUTES WITHIN THE MULTIFAMILY DWELLING UNIT SHALL <br />C. CABINETS UNDER THE LAVATORY ARE PERMITTED PROVIDED A PARALLEL APPROACH IS <br />COMPLY WITH SECTION 1131A. <br />SWITCHES AND CONTROLS THAT DO NOT SATISFY THESE SPECIFICATIONS ARE ACCEPTABLE, <br />PROVIDED AND THE CABINETS ARE DESIGNED TO PROVIDE THE ADAPTABLE KNEE AND TOE <br />A. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED i". <br />PROVIDED THAT COMPARABLE CONTROLS OR OUTLETS, THAT PERFORM THE SAME <br />SIN z � <br />M z w <br />CLEARANCES. <br />o <br />B. WHEN CHANGES IN LEVEL DO OCCUR, THEY SHALL BE BEVELED WITH A SLOPE NO GREATER <br />FUNCTIONS, ARE PROVIDED WITHIN THE SAME AREA AND ARE ACCESSIBLE.. <br />OBSTRUCTION z z � <br />D. KNEE AND TOE CLEARANCE SHALL BE PROVIDED AS SHOWN BELOW. A MAXIMUM OF 19" OF <br />z <br />THAN 1 UNIT VERTICAL TO 2 UNITS HORIZONTAL (50%SLOPE). <br />Q � w <br />p > <br />THE REQUIRED FORWARD APPROACH MAY BE PROVIDED BY KNEE AND TOE CLEARANCES. A <br />X <br />Q <br />C. CHANGES IN LEVEL NOT EXCEEDING 4" MAY BE VERTICAL. <br />EXCEPTIONS INCLUDE APPLIANCES (KITCHEN STOVES, DISHWASHERS, RANGE HOODS, <br />? m o <br />MAX. OF 6" OF THE REQUIRED FORWARD APPROACH MAY BE PROVIDED BY TOE CLEARANCE. <br />g <br />6' A . 48 MIN. 6' <br />D. CHANGES IN LEVEL GREATER THAN i SHALL BE MADE BY MEANS OF A RAMP, ELEVATOR OR <br />MICROWAVE OVENS, LAUNDRY EQUIPMENT AND SIMILAR APPLIANCES) THAT HAVE CONTROLS <br />a J <br />I- LL <br />E. THE FLOOR FINISH BENEATH THE LAVATORY SHALL EXTEND TO THE WALL. <br />M Q <br />2" <br />PLATFORM LIFT. <br />LOCATED ON THE APPLIANCE. <br />z �_ _ = <br />F. HOT WATER & DRAIN PIPES EXPOSED UNDER LAVATORIES SHALL BE INSULATED OR <br />w <br />`" <br />OTHERWISE COVERED. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER <br />in <br />M _ LL <br />LAVATORIES. <br />/ <br />ACCESSIBLE ROUTE <br />2 <br />G. LAVATORY FAUCET CONTROLS AND OPERATION MECHANISMS SHALL BE OPERABLE WITH <br />ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE <br />SWITCHES AND OUTLETS <br />21 <br />GRAB BARS <br />% <br />1 <br />WRIST. THE FORCE TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUND -FORCE. <br />36" MIN. CLR. <br />z <br />PRIMARY ENTRY DOORS AND REQUIRED EXIT DOORS SHALL COMPLY WITH SECTION 1132A.1. <br />/ <br />LEVER OPERATED, PUSH -TYPE, AND ELECTRONICALLY CONTROLLED MECHANISMS ARE <br />- <br />THE REQUIREMENTS OF SECTION 1126A.3 SHALL APPLY TO THE MANEUVERING CLEARANCES AT THE SIDE OF THE <br />EXAMPLES OF ACCEPTABLE DESIGNS. SELF -CLOSING VALVES ARE ALLOWED IF THE FAUCET <br />LAVATORY/VANITY WITH FIXED 18" MIN. 17" - 18" <br />M <br />DOOR EXPOSED TO COMMON OR PUBLIC USE SPACES, INCLUDING ENTRY OR EXIT DOORS WHICH OPEN FROM THE <br />KITCHENS SHALL COMPLY WITH CBC SECTION 1133A CLEAR FLOOR SPACE AT APPLIANCES & FIXTURES <br />REMAINS OPEN FOR AT LEAST 10 SECONDS. <br />H. WHERE MIRRORS OR TOWEL FIXTURES ARE PROVIDED, AT LEAST ONE OF EACH SHALL BE <br />CABINETRY PERMITTED <br />Q <br />COVERED MULTIFAMILY DWELLING UNIT INTO A CORRIDOR, HALLWAY OR LOBBY, OR DIRECTLY TO THE OUTSIDE. <br />A. CLEAR FLOOR SPACE <br />ACCESSIBLE AND SHALL BE MOUNTED WITH THE BOTTOM EDGE NO HIGHER THAN 40" FROM <br />INTERIOR DOORS AND SECONDARY EXTERIOR DOORS SHALL COMPLY WITH SECTION 1132A.2. <br />1. A CLEAR FLOOR SPACE SHALL BE PROVIDED FOR PARALLEL APPROACH AT A <br />THE FLOOR. <br />EXCEPT AS ALLOWED BY SECTION 1109A.2, INTERIOR DOORS INTENDED FOR USER PASSAGE AND SECONDARY <br />RANGE OR COOKTOP. -- - -- - - <br />2. A CLEAR FLOOR SPACE THAT PERMITS EITHER PARALLEL OR FORWARD <br />�; \\ ,� <br />`\ <br />BACK WALL <br />EXTERIOR DOORS SHALL COMPLY WITH THIS SECTION. THE PROVISIONS OF THIS SECTION SHALL APPLY TO THE <br />DWELLING UNIT SIDE OF DOORS LEADING FROM THE INTERIOR OF THE DWELLING UNIT TO AN UNFINISHED <br />APPROACH SHALL BE PROVIDED AT THE KITCHEN SINK AND ALL OTHER FIXTURES �- ------ - - -- - - <br />\ <br />- Q- <br />BASEMENT OR ATTACHED GARAGE. <br />�` <br />vv <br />OR APPLIANCES. �' <br />\�� Ii <br />i <br />a <br />3. THE CENTERLINE OF THE PROVIDED SPACE SHALL BE ALIGNED WITH THE <br />`` �' II <br />CENTERLINE OF THE FIXTURE OR APPLIANCE. <br />\ <br />I \ / <br />I <br />J <br />J � <br />O O <br />A. THE WIDTH AND HEIGHT OF DOORS SHALL COMPLY WITH THE FOLLOWING: <br />1. DOORS SHALL BE NOT LESS THAN 6'-8" IN HEIGHT <br />REFRIGERATOR 1 II <br />ti I \ , <br />of Q <br />2. SWINGING DOORS MUST PROVIDE A MINIMUM NET CLEAR OPENING WIDTH OF 32', MEASURED WITH THE <br />PARALLEL OR FORWARD - �- - - <br />B. CLEAR WIDTH y' <br />Q I \ / <br />= I <br />z w <br />o = <br />DOOR OR DOORS POSITIONED AT AN ANGLE OF 90-DEGREES FROM THE CLOSED POSITION. A 34' DOOR IS <br />APPROACH REQUIRED �' II <br />1. U-SHAPED KITCHENS WITH A PARALLEL APPROACH AT A RANGE OR COOKTOP AT <br />1 <br />ACCEPTABLE. <br />THE BASE OF THE "U" SHALL HAVE A MINIMUM CLEAR WIDTH OF 60". (FIGURE A) ��ii <br />z_ <br />3. SWINGING DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES WITHIN THE DWELLING UNIT. <br />2. U-SHAPED KITCHENS WITH A COOKTOP OR SINK AT THE BASE OF THE "U" WITH A `------- -- - -- - - <br />/ \ w <br />J <br />`� �' <br />4. A NOMINAL 32"CLEAR OPENING PROVIDED BY A STANDARD 6' WIDE SLIDING PATIO DOOR IS ACCEPTABLE. <br />1 <br />FORWARD APPROACH SHALL HAVE A MINIMUM CLEAR WIDTH OF 48". (FIGURE B <br />I ` U <br />°° I \ <br />\` '� <br />5. A PAIR OF DOORS, MANUAL OR AUTOMATIC, MUST HAVE AT LEAST ONE LEAF THAT PROVIDES A CLEAR <br />AND C) L <br />I ; `\ � <br />.� <br />�� <br />WIDTH OF NOT LESS THAN 32", MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90-DEGREES <br />-- -----1-J <br />3. ALL OTHER KITCHENS SHALL HAVE A MIN. CLR. WIDTH OF 48". (FIGURE D) <br />i `\ g <br />Z <br />FROM ITS CLOSED POSITION. <br />4. U SHAPED KITCHENS WITH A SINK AND DISHWASHER AT THE BASE OF THE "Ur' <br />I \\ <br />B. FLOOR OR LANDING ON EACH SIDE OF THE DOOR SHALL BE LEVEL AND CLEAR. CHANGES IN HEIGHT BETWEEN <br />----------- <br />SHALL HAVE A MINIMUM CLEAR WIDTH OF 68" TO ACCOMMODATE THE PARALLEL \- <br />/� 2 <br />I / \ <br />_ �' `� <br />co �\ <br />co <br />LANDINGS SHALL COMPLY WITH CBC SECTION 1126A.2 OUTSIDE THE UNIT, SEE DETAIL 6 SHEET AD-02, AND <br />APPROACH OF BOTH THE SINK AND THE DISHWASHER. (FHA 7.9) (FIGURE E) `\ /' <br />i 1! ___ _______ ` <br />�' `�\ <br />CBC SECTION 1132A.4 WITHIN THE UNIT, SEE DETAIL 4 THIS SHEET. <br />_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ -� <br />C. MANEUVERING CLEARANCES AT DOORS SERVING COVERED DWELLING UNITS SHALL COMPLY WITH CBC <br />C. REMOVEABLE CABINETRY REQUIRED ���----�-- \` ----- �- %� <br />MIRROR <br />SECTION 1132A.5 (SEE FIGURES BELOW) AND CBC SECTION 1126A.3 FOR OTHER DOORS. <br />1. BASE CABINETS AND SHELVING DIRECTLY BELOW THE KITCHEN SINK COUNTER FUNCTIONAL 30"X48" 1 `� `\ , �' <br />48" MINIMUM <br />48" MINIMUM <br />D. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 81/2 POUNDS FOR EXTERIOR DOORS AND 5 <br />AREA SHALL BE REMOVEABLE WITHOUT THE USE OF SPECIALIZED TOOLS OR CLEAR SPACE FOR <br />CLEAR (FHA 7.43). <br />POUNDS FOR INTERIOR DOORS. WHEN FIRE DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE <br />KNOWLEDGE. APPLANCE WITH `. �' \/ <br />DOOR MAY BE INCREASED TO THE MINIMUM ALLOWABLE BY THE APPROPRIATE ENFORCEMENT AGENCY, NOT <br />2. KNEE SPACE PER 1134A.8, #4. PULL OUT OR PULL/\\ <br />RIM/COUNTER <br />TO EXCEED 15 POUNDS. <br />3. THE FINISH FLOOR BELOW THE KITCHEN SINK SHALL BE EXTENDED TO THE WALL. DOWN DOOR (FHA) ��1/ `, Ii <br />E. IF THE DWELLING UNIT ENTRY DOOR HAS A CLOSER, THEN THE SWEEP PERIOD OF THE CLOSER SHALL BE <br />KNEE <br />ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO <br />---' - II - ' - - <br />J <br />KNEE <br />�` <br />MOVE TO A POINT 3 INCHES FROM THE LATCH, MEASURED TO THE LANDING EDGE OF THE DOOR (SECTION <br />`�-----� - -----�---- <br />D. COUNTERTOPS 1 `�� /' _ � \ II \ 1 �'� <br />t <br />1126A.4.1 AND FHA REQ. 3). <br />1. A MIN. LINEAR LENGTH OF 30" SHALL BE PROVIDED FOR THE INSTALLATION OF II / \ ' <br />OVEN, DISHWASHER AND �� ` ' <br />F. HAND -ACTIVATED DOOR LATCHING, LOCKING AND OPENING HARDWARE SHALL BE CENTERED BETWEEN 30" <br />THE KITCHEN SINK. �\ �� <br />AND 44"ABOVE THE FLOOR. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND ON AN <br />TRASH COMPACTOR _ I it \ I' <br />2. A MIN. LINEAR LENGTH OF 30" SHALL BE PROVIDED FOR A WORK SURFACE. TWO PARALLEL OR FORWARD 1 - II ; `i <br />t Q <br />~ Q g <br />z <br />ACCESSIBLE ROUTE SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, <br />15" BREADBOARDS MAY BE PROVIDED IN LIEU OF WORK SURFACE 1 y' 1 ' ` <br />APPROACH REQUIRED II 1 `\ <br />i w X _ <br />O Q o <br />PUSH-PULL ACTIVATING BARS OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING <br />�' �' <br />3. MIN. 5 PERCENT OF COVERED DWELLING UNITS MUST PROVIDE �' I / 1 \ 1 <br />t <br />THE ABILITY TO GRASP THE HARDWARE. <br />RE-POSITIONABLE COUNTERTOP WORK SURFACE AND SINK PER CBC 1133A.4.1.----�---- <br />i <br />G. LEVER OR LEVER ACTUATED LATCHES OR LOCKS SHALL BE CURVED TO RETURN TO WITHIN 1/2" OF THE DOOR <br />STONE, CULTURED STONE, AND TILED COUNTERTOPS DO NOT NEED TO MEET `� ------ -- - -- - - <br />z `' <br />? t <br />TO PREVENT CATCHING OF CLOTHING OF PERSONS DURING EGRESS IN GROUP R AND U OCCUPANCIES WITH <br />THE REPOSITIONING REQUIREMENTS. TWO 15" BREADBOARDS MAY BE I <br />AN OCCUPANT LOAD GREATER THAN 10. <br />PROVIDED IN LIEU OF THE RE-POSITIONABLE COUNTERTOP WORK SURFACE L -- - -- J 1 <br />--� <br />i _ TOE <br />- _ N <br />H. THE BOTTOM 10" OF ALL DOORS SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO <br />a. THE KITCHEN SINK AND WORK SURFACE COUNTERTOP SHALL BE DESIGNED <br />BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. WHERE <br />TO ENABLE REPOSITIONING TO A MINIMUM HEIGHT OF 28". REQUIRED 30"X48" <br />NARROW FRAME DOORS ARE USED, A 10" HIGH SMOOTH PANEL SHALL BE INSTALLED ON THE PUSH SIDE OF <br />CLEAR SPACE AT ----- - T- -- - - <br />b. BASE CABINETS DIRECTLY UNDER THE KITCHEN SINK AND WORK SURFACE COOKTOP (FORWARD I \\ I 1 I <br />WATER CLOSET <br />10 <br />BATHTUB <br />6 <br />THE DOOR. <br />I. EVERY PRIMARY ENTRY DOOR TO A COVERED MULTI DWELLING UNIT SHALL BE PROVIDED WITH A <br />SHALL BE REMOVABLE AS REQUIRED IN SECTION 1133A.3. I <br />I <br />-FAMILY <br />\ , I <br />APPROACH WITH KNEE! \ I I <br />c. THE SIDES OF ADJACENT CABINETS AND THE BACK WALL SHALL BE I \ , 1 <br />SPACE AS ALTERNATES <br />1 <br />DOOR BUZZER, BELL, CHIME OR EQUIVALENT. THE ACTIVATING MECHANISM SHALL BE MOUNTED A MAXIMUM <br />OF 48" ABOVE THE FLOOR AND CONNECTED TO PERMANENT WIRING. <br />\ <br />CONSTRUCTED OF DURABLE AND NONABSORBENT MATERIALS. I \ I I 1 <br />8" DEEP KNEE <br />d. FINISHED FLOORING SHALL BE EXTENDED TO THE WALL BENEATH THE I ` 4 OI O <br />I \\ /' I <br />CLEARANCE 30" WIDE <br />SHOWERS REQUIRED TO BE ACCESSIBLE SHALL COMPLY WITH SECTION 1134A.6 <br />PRIMARY ENTRY (MIN. 3' 0" WIDE DOOR INTERNAL UNIT DOOR <br />KITCHEN SINK AND WORK SURFACE. I I <br />RANGE OR COOKTOP I \\// I I <br />11" DEEP KNEE ---- <br />- I - /\ - I- <br />ONLY PARALLEL I / \ I <br />CLEARANCE 30" WIDE <br />A. GRAB BAR REINFORCEMENT SHALL BE INSTALLED CONTINUOUS IN THE WALLS OF <br />___________ <br />INTERIOR SIDE 1 <br />E. KITCHEN SINK FAUCET APPROACH REQUIRED. I / \ I 1 OI O <br />`,�- - - - - I <br />SHOWERS 32 INCHES TO 38 INCHES ABOVE THE FLOOR AND MINIMUM OF 6 INCHES <br />z 1 <br />I /' <br />CONTROLS AND OPERATION MECHANISMS SHALL BE OPERABLE WITH ONE HAND I / 1 \ I / I <br />1 \ 1 <br />17" MIN. DEEP TOE <br />CLEARANCE 30" WID <br />NOMINAL IN HEIGHT. (CBC 1134.6.4) <br />B. WHEN A THRESHOLD IS USED, IT SHALL BE A MAXIMUM OF 2 INCHES IN HEIGHT AND HAVE <br />18" iv Z 18" <br />MIN. MIN. <br />AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. REQUIRED ' 1 \ 1 / 1 <br />v <br />THE FORCE TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5PQUND-FORCE. FUNCTIONAL 30"X48" <br />ABEVELED OR SLOPED ANGLE NOT EXCEEDING 1 UNIT VERTICAL IN 2 UNITS HORIZONTAL. <br />LEVER OPERATED, PUSH -TYPE, AND ELECTRONICALLY CONTROLLED MECHANISMS CLEAR SPACE AT I /_ � I 1 <br />THRESHOLD' INCH OR LESS IN HEIGHT MAY HAVE A BEVELED OR SLOPED ANGLE NOT <br />------- ------- <br />------- ------- <br />_ <br />ARE EXAMPLES OF ACCEPTABLE DESIGNS. SELF CLOSING VALVES ARE ALLOWED IF RANGE PULL DOWN -\\ / -� <br />EXCEEDING 45 DEGREES FROM HORIZONTAL. (CBC 1134.6.5) <br />= 1 1 * IF A CLOSER I .* <br />32" NET. I 32" MIN. LANDING MAY <br />\ / <br />THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS. DOOR (FHA) V <br />U <br />z_ Z Z Q CLEAR OR A CLOSER _ CLR.** <br />BE REDUCED <br />\\ <br />p 0 1 I I <br />IAT i AND A LATCH Z I I <br />// <br />54" HINGE TO 39" IF DOOR <br />L ' <br />/ \ <br />\\ <br />- w ARE PROVIDED <br />oo LL a APIPROACH 1 i i PROVIDES 34" <br />-,mnwd.nks Nerw 4r lelk // <br />� / \ <br />wall -mounted <br />CONTROL WALL <br />� Q 1 I I <br />EXTERIOR S DE L-------J CLR. OPENING. <br />L---1------- <br />.ern rer, wc.rd m.ede".m e.ir <br />kr�m,..p.r,. <br />space s•i"�+•d hr ANSI <br />. �.d.�.r. <br />countertop <br />counterto r <br />countertop <br />-J _ DOOR <br />FRONT <br />1 <br />\\ <br />1 pMR"aaar.a AI <br />Nmpm------------� <br />support brackets lavatory <br />// <br />1 \ / MAXIMUM 1/2" : V-0" <br />DOOR 2'-O" LATCH APPROACH WIDTH <br />Pure piper <br />diWrwlshe.sn 9e <br />\\\\ x U i SLOPE <br />�\ w <br />WIDTH <br />_ .roped is wuloraa <br />GARBAGE � i <br />DISPOSAL TO BE ,,,, I - -- - - 1 <br />L____ <br />remova#3le <br />i J <br />z \\ I \\ // Q � U <br />- \ / � z <br />DOORS <br />- - f h ek-d CLEAR OF REQUIRED <br />KNEE SPACE -- - - -- - -------� <br />g I\ x Q <br />bo i `\\ / \ w <br />r vanity cabinet <br />_ <br />` 30M��' \ <br />DOOR LANDINGS SHALL COMPLY WITH CBC SECTION 1132A.4 <br />A. THE FLOOR OR LANDING ON EACH SIDE OF A DOOR SHALL BE LEVEL. PRIMARY ENTRY DOORS, REQUIRED EXIT <br />KITCHEN SINK _ _ �` _ <br />kY _'. % PARALLEL OR FORWARD <br />I SEAT WALL <br />DOORS OR SECONDARY EXTERIOR DOORS WITH CHANGES IN HEIGHT BETWEEN THE INTERIOR SURFACE OR <br />FLOOR LEVEL AND THE EXTERIOR SURFACE OR FLOOR LEVEL SHALL COMPLY WITH THE FOLLOWING: <br />" �•�. + ` �' + WITH KNEE SPACE 1 �'\ 1 /� ` <br />APPROACH REQUIRED, '� `� <br />�--------- __\` <br />48" MIN. CLEAR <br />B. EXTERIOR LANDINGS OF IMPERVIOUS CONSTRUCTION SERVING PRIMARY ENTRY DOORS AND REQUIRED EXIT <br />DOORS ARE LIMITED TO NOT MORE THAN 1/2" OF CHANGE IN HEIGHT BETWEEN FLOOR SURFACES. CHANGES <br />BASE CABINETS DIRECTLY- <br />IN LEVEL SHALL EXCEEDING 1/2" SHALL BE MADE BY MEANS OF A RAMP WITH A MAXIMUM RAMP SLOPE NO <br />1 UNDER THE KITCHEN SINK <br />.ss:-; <br />GREATER THAN 1 :12 (8.33%) PER CBC SECTION 1122A.2. <br />COUNTER AREA MUST BE <br />"' -" " <br />36" MIN CLEAR PATH <br />C. EXTERIOR LANDINGS OF IMPERVIOUS CONSTRUCTION SERVING SECONDARY EXTERIOR DOORS ONTO DECKS, <br />- <br />REMOVABLE TO PROVIDE L -- - -- J <br />,t'�'�'t- <br />{i <br />.•. - ,';:;: <br />39" IF 3' DR INSTALLED <br />PATIOS OR BALCONY SURFACES MAY HAVE A MAXIMUM CHANGE IN HEIGHT FROM THE INTERIOR LANDING OF <br />1", PROVIDED A RAMP WITH A MAXIMUM SLOPE OF 1 : 8 (12.5% IS PERMANENTLY INSTALLED. <br />KITCHENS SHALL HAVE A MINIMUM CLEAR WIDTH MEASURED BETWEEN ANY CLEARANCE FORA <br />_-_ <br />:::::•�t:• <br />CABINET, COUNTERTOP OR THE FACE OF ANY APPLIANCE EXCLUDING <br />( WHEELCHAIR. (CBC 1133A.3) <br />- -- - - <br />,:;:;�:-:;:;. ' ' <br />1O 42 INCH ROLL -IN <br />THRESHOLDS SHALL COMPLY WITH CBC SECTION 1132A.4.1 <br />A. THRESHOLD AT PRIMARY ENTRY DOORS AND REQUIRED EXIT DOORS SHALL BE NO HIGHER THAN 112". <br />HANDLES AND CONTROLS) THAT PROJECTS INTO THE KITCHEN AND THE /-- <br />OPPOSING CABINET, COUNTERTOP, APPLIANCE OR WALL AS FOLLOWS: <br />:-::•:k <br />:'••� t�- _::::' I <br />B. THRESHOLDS AT UNIT SECONDARY EXTERIOR DOORS AND SLIDING GLASS DOORS SHALL BE NO HIGHER THAN <br />-0" 48" MIN. CLEAR <br />3/4". <br />MAX <br />C. MATERIAL CHANGES IN HEIGHT AT INTERIOR DOOR THRESHOLDS SHALL NOT EXCEED 1/2". <br />60" 48" ��' W <br />MINIMUM CLEAR INIMUM CLEA 1 1 v <br />30" CLEAR WORK SURFACE �' <br />WIDTH WIDTH - - o <br />PARALLEL OR FORWARD WITH 1 �� 1 D <br />KNEE SPACE APPROACH <br />I <br />I <br />------------------- <br />`�� ��' <br />`� i' <br />z <br />g <br />D. THRESHOLDS WITH A CHANGE IN HEIGHT OF NOT MORE THAN 1/4" MAY BE VERTICAL. <br />E. THRESHOLDS WITH A CHANGE IN HEIGHT BETWEEN 1/4" AND 3/4" SHALL BE BEVELED WITH A SLOPE NO <br />GREATER THAN 1 :2 (50%). <br />- REQUIRED, BASE CABINETS, '� \`� z <br />1 �'� �`. Mo <br />F--- �' `� 2 <br />SHELVING, AND TOE KICK <br />I �' `� <br />PRIMARY ENTRY AND REQUIRED EXIT DOORS <br />�� _ _ _ <br />DIRECTLY UNDER WORKSPACE <br />i0 COUNTER MUST BE REMOVABLE <br />z <br />�� ------_---____� <br />X Q <br />L -- - <br />Q TO PROVIDE 30 MINIMUM <br />1 __ w <br />O O r-� w CLEARANCE FOR A WHEELCHAIR. <br />`\\� <br />MAXIMUM 1/2": 1'-0" J Q <br />LOCATE w <br />a U <br />X X Q <br />o- <br />------ i i i - - - - -T /' v C) (CBC 1133A.3) <br />Removing n VanityCabinet <br />SPRAY ON WALLOFLUSH AND � U <br />\ w <br />� � RAMP � g � g <br />\ / 1 /r 00 ��0 <br />RANGE OR i <br />i� <br />O ? <br />� <br />12 1 I 7 <br />\\ /, // \� <br />/x\� I COOKTOP i <br />�\ <br />Exposeto n <br />PARALLEL WITH MANEUVERING <br />; <br />�\ I I i \ , <br />WITH I x z <br />SPACE OUTSIDE THE SHOWER z <br />o0 <br />I <br />I 1 � <br />TYPICAL ALL SHOWER PLANS <br />PARALLEL I 1 <br />0 ___ I APPROACH I I / ` <br />O2 60 INCH ROLL -IN <br />W <br />> w <br />----- L ____ <br />SINK OR COOKTOP <br />REAR WALL <br />w w ° <br />� z V) 2 /o MAX <br />O O {� <br />_ ED <br />WITH FORWARD <br />N w z EXTERIOR <br />APPROACH <br />5'-0" MIN. CLEAR ENTRANCE <br />N Q � o LANDING SLOPE <br />FIGURE A FIGURE B <br />w Q <br />30" MIN. 3'-0" MIN. CLEAREXTERIOR-DOORN <br />CO <br />SECONDARY <br />SEE CBC 1133A.2.1 "CLEAR WIDTH" NOTE #1 SEE CBC 1133A.2.1 "CLEAR WIDTH" NOTE #2 <br />39" IF 3' DR INSTALLE <br />48" 48„ <br />MINIMUM CLEAR <br />_ 48„ INIMUM CLEA <br />Olt— OP INIMUM CLEA WIDTH WIDTH <br />WIDTH <br />CONTROL WALL <br />i \\ �,iil / 1 <br />i \\ ,'�/ z <br />J <br />Q U <br />X w <br />> RAMP < CU <br />8 - <br />/ \ zI <br />M <br />F- O IOI- \ <br />/ 1 /x\ Z O O J Q LU <br />w I / \ J Q J <br />Q W T 1 <br />> <br />\ //� I <br />1 \ OIO I Q OI Q <br />1 1 J <br />i // \\� LL 1 2= U <br />I / �- I X-r <br />�_ I--�� -----\ b� Q w z <br />m H W 2% MAX <br />M U) w z EXTERIOR <br />I I :\ /�L I 1 0� 0 1O� \ / �_ <br />I I I \ / 1 <br />i i g_ <br />I // \\ O <br />'�' `y `� <br />LANDING SLOPE <br />w Q <br />m <br />X <br />01 v i �'\`x'�`�i i i z\\`x'// <br />00 � z <br />INTERIOR FLOOR MATERIAL CHANGES J <br />00 / \ y I / \ <br />O1 O g I <br />< > BEVEL <br />w 2 FINISH <br />I 1 - I 1 1 <br />zF L--- I/-- \ 1 1 _ \i __� ---- 1 1 <br />g I} �� r �'� ? SINK OR COOKTOP 0-0 <br />3 ALTERNATE ROLL IN <br />COMPRESSED CARPET 1/2" -1 FLOOR EVEN <br />MAX. BELOW THRESHOLD y <br />----y WITH FORWARD <br />APPROACH <br />MAT CARPETING MUST CONSIST OF: <br />FIGURE D FIGURE E 68" FIGURE C <br />A. LEVEL LOOP X Q DOOR THRESHOLD <br />INIMUM CLEAR VVIDT4 <br />B. TEXTURED LOOP 2 v <br />SEE CBC 1133A.2.1 "CLEAR WIDTH" NOTE #3 SEE CBC 1133A.2.1 "CLEAR WIDTH" NOTE #2 SEE CBC 1133A.2.1 "CLEAR WIDTH" NOTE #2 <br />C. LEVEL CUT PILE = <br />D. LEVEL CUT/UNCUT PILE > <br />KITCHEN REQUIREMENTS - <br />20 <br />LAVATORY SINK <br />16 <br />- <br />9 <br />SHOWER <br />8 <br />LANDINGS & THRESHOLDS <br />4 <br />Architecture + Planning <br />17911 Von Karman Ave. <br />Suite 200 <br />Irvine, CA 92614 <br />ktgy.com <br />949.851.2133 <br />KTGY Project No: 2017-0934 <br />Project Contact: Debbie Holland <br />Email: dholland@ktgy.com <br />Principal: Wil Wong <br />Project Designer: D. Schoolmeester <br />Project Director: Debbie Holland <br />Developer <br />ED OAK <br />INVL�'S"I' AL:N I'S <br />4199 CAMPUS DRIVE <br />IRVINE, CA 92612 <br />PHONE NO. (714) 342-2502 <br />1 <br />TF <br />T- <br />C) <br />N <br />Q <br />U <br />Q <br />z <br />Q <br />Q <br />z <br />Q <br />U) <br />LLI <br />Ll_i <br />U) <br />FICT <br />- <br />LLI <br />No. Date Description <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />��SED T��ARCh,� <br />� <br />No. C29795 <br />RENEWAL DATE <br />AUGUST 31, 2023 <br />s�gTF <br />OF C A�-� <br />License Stamp <br />DWELLING UNIT <br />ACCESSIBILITY <br />DETAILS <br />AD-03 <br />Z <br />^J <br />rI- <br />V <br />ILL <br />N <br />C) <br />CN <br />Ir- <br />C) <br />00 <br />CI <br />COPYRIGHT U <br />