Laserfiche WebLink
NON -PLUMBING SIDE <br />(E.G., BEDROOM, DINING ROOM) <br />PLUMBING WALL <br />VCCrl P11-117' nl CAI-] nr Crr71 Inrl Ir)C. <br />211 FELT ISOLATION <br />KEEP PIPE CLEAR OF STRUCTURE <br />ACOUSTI-PLUMB ISOLATORS <br />MINIMUM 1-1/2" CLEARANCE <br />FROM GYPSUM BOARD SURFACE <br />ADJUST THICKNESS OF PARTITION <br />TO ALL PIPES AND PLUMBING <br />ACOUSTO-SCUTCHEON <br />FILL FRAMING CAVITY WITH BATT <br />INSULATION <br />WOOD STUD <br />GYPSUM BOARD <br />NOTE: FLOOR/CEILING CONDITIONS SIMILAR <br />DRAIN &SUPPLY PIPES IN PLUMBING WALL 22 <br />1/4" - 1/2" NOMINAL <br />31LIENT WRAP 1/4" <br /><. FELT PAD OR EQUAL <br />ING OR NOTCHES PER C.B.C. <br />. 2326.11.10 AND PER STRUCT. <br />.APPROVAL <br />17 <br />CAULK AIRTIGHT. USE FIRE -RATED <br />RESILIENT FILLER IF REQUIRED FOR <br />FIRE RATING <br />STEEL PLATE (OPTIONAL) <br />3/4" NEOPRENE PAD 40-DUROMETER <br />FLOOR CONSTRUCTION <br />SAFING BATT INSULATION IF <br />REQUIRED FOR FIRE RATING <br />0 <br />0 <br />O <br />O <br />O <br />O <br />O <br />0 <br />WALL PENETRATION INSTALLATION <br />0 <br />0 <br />O <br />O <br />O <br />0 <br />0 <br />O <br />O <br />O <br />I� 0 <br />II <br />TUB/SHOWER VALVE INSTALLATION <br />NOTE: IF PIPE IS SUSPENDED FROM OR DIRECTLY ATTACHED TO STRUCTURE OR OTHER BUILDING TYPICAL ALL DETAILS ABOVE ARE SHOWN WITH ACOUSTO-PLUMB ISOLATORS <br />ELEMENTS, USE 1/2" THICK, 40-DUROMETER NEOPRENE AS SLEEVE BETWEEN PIPE AND PIPE COLLAR NOTE: LOCATE PIPING 1-1/2" MIN. CLEARANCE OF GYPSUM BOARD <br />SUPPLY PIPE ISOLATION 18 ACOUSTO-PLUMB ISOLATION 14 <br />FASTEN CLAMP TO STRUCTURE (TYP.) <br />TRISOLATOR PIPE SLEEVE: <br />SERIES 100 FOR STEEL PIPE <br />OR <br />SERIES 500 FOR COPPER <br />KEEP PIPE CLEAR OF STRUCTURE, <br />OTHER PIPES, AND OTHER TRADES <br />TRISOLATOR AVAILABLE THROUGH: <br />ELMDOR/STONEMAN ENGINEERING; (800) 591-9181 <br />TRISOLATOR ISOLATION <br />JOIST BAY INSTALLATION <br />0 <br />0 <br />O <br />�O <br />VERTICAL STUD BAY INSTALLATION <br />HIGH EAR ACOUSTO-CLAMP <br />ACOUSTO-LATOR <br />O\ <br />\O <br />ACOUSTO-CLAMP <br />ACOUSTO-SCUTCHEON <br />aammaa0.0.0.0.0a000mmaamm <br />METAL BRACKET <br />(SIZES VARY: COMES IN ACOUSTO-KIT WITH TWO ACOUSTO-LATORS) <br />ACOUSTO-PLUMB SYSTEM COMPONENTS ARE AVAILABLE THROUGH: <br />LSP/SPECIALTY PRODUCTS; (800)854-3215 <br />NOTE 4 <br />NOTE 3 <br />NOTE 2 <br />GENERAL NOTES <br />THE DETAILS & NOTES ON THIS SHEET ARE SHOWN AS A MINIMUM ALLOWED BY THE <br />6" MAX. C.B.C. IN CONJUNCTION WITH THE GYPSUM ASSN. GA 600 MANUAL, THE U.L. DIRECTORY <br />OF FIRE RESISTANCE, AND THE CALIFORNIA DEPT. OF HEALTH SERVICE AND OFFICE OF <br />EQ. (NOTE 1) NOISE CONTROL (C.O.N.C.) CATALOG OF S.T.C. AND ICC RATINGS. <br />THE CONTRACTOR WILL OBTAIN A COPY OF THE LISTED ASSEMBLIES NOTED FOR <br />INSTALLATION AND FINISH ATTACHMENT REQUIREMENTS. <br />EQ. <br />EQ. <br />EQ. <br />EQ. <br />6" MAX <br />ING FLANGE <br />SCREW <br />SECTION THROUGH RESILIENT <br />CHANNEL <br />NOTES: <br />1. INSTALL CHANNELS 16" ON CENTER UNLESS OTHERWISE SPECIFIED <br />2. AVOID STUD OR JOIST WHEN FASTENING GYPSUM BOARD TO CHANNEL- GYPSUM <br />BOARD SCREWS MUST NOT CONTACT FRAMING <br />3. HOLD BACK 1/2" FROM INTERSECTING SURFACES <br />4. DO NOT CANTILEVER CHANNEL BY MORE THAN 6" FROM FRAMING <br />RESILIENT CHANNEL CONSTRUCTION <br />ATTACH CHANNELS DIRECTLY TO THE FRAMING SYSTEM ONLY. DO NOT INSTALL CHANNELS ON <br />GYPSUM BOARD, SHEAR PLYWOOD, OR LIKE MATERIAL. <br />A. ATTACHING CHANNELS <br />1. ATTACH SINGLE LEG RESILIENT CHANNELS SPACED PER FIRE RATED ASSEMBLY. USE DIETRICH <br />INDUSTRIES (800/873-2443) RC DELUXE 25-GAUGE RESILIENT CHANNELS OR SINGLE -LEG CHANNELS <br />THAT CAN BE SHOWN TO HAVE EQUIVALENT LABORATORY ACOUSTICAL PERFORMANCE TO USG RC-1 <br />CHANNELS. KINETICS ISOMAX CHANNELS RECOMMENDED AT BEDROOMS BELOW LIVING AREAS. <br />2. USE 1" TYPES BUGLE HEAD DRYWALL OR SIMILAR SCREWS. SPLICE CHANNELS ONLY AT <br />FRAMING AND OVERLAP BUTT ENDS NO MORE THAN 1-1/2" UNLESS NOTED OTHERWISE BY RATED <br />ASSEMBLY. SCREW ATTACH THROUGH BOTH FLANGES. <br />3. ATTACH CHANNELS WITH MOUNTING FLANGES FACING IN ONLY ONE DIRECTION. FOR WALLS, THE <br />GYPSUM BOARD MOUNTING FLANGE WOULD FACE UPWARD AND PREPUNCHED HOLES DOWNWARD. <br />4. HOLD BACK ENDS OF CHANNELS 1/2" FROM INTERSECTING SURFACES. <br />5. LOCATE CHANNELS A MAXIMUM OF 3" FROM FRAMING AT BASE AND HEAD OF WALL. <br />7. ADD ADDITIONAL FRAMING IF NECESSARY SO THAT CHANNELS ARE CANTILEVERED NO MORE <br />THAN 6". <br />B. ATTACHING GYPSUM BOARD <br />1. APPLY GYPSUM BOARD OF MAXIMUM PRACTICAL LENGTH ORIENTED PER THE RATED ASSEMBLY. <br />2. FASTEN GYPSUM BOARD TO CHANNELS, PER FIRE RATED ASSEMBLY AND DO NOT SCREW INTO <br />FRAMING. <br />3. LOCATE GYPSUM BOARD 1/4" FROM INTERSECTING SURFACES. <br />C. TWO -LAYER OPTION <br />1. WHEN A CONSTRUCTION WITH TWO LAYERS OF GYPSUM BOARD ON RESILIENT CHANNELS IS <br />RECOMMENDED, APPLY THE FACE GYPSUM BOARD LAYER IN THE SAME MANNER AS THE BASE <br />LAYER, EXCEPT OFFSET THE LONG EDGE JOINTS BY 24" AND THE SHORT EDGE JOINTS BY 48". <br />2. FASTEN THE FACE LAYER PANEL TO CHANNELS PER RATED ASSEMBLY AND DO NOT SCREW INTO <br />FRAMING. <br />3. OFFSET FACE LAYER SCREW PATTERN 6 INCHES FROM BASE LAYER SCREWS ALONG ALL <br />CHANNELS. <br />4. HOLD BACK EDGES OF RESILIENTLY HUNG GYPSUM BOARD 1/4" AT ALL INTERSECTING SURFACES. <br />10 D. CAULKING GYPSUM BOARD/RESILIENT CHANNEL CONSTRUCTION <br />1. FOR ALL CONSTRUCTIONS, CAULK THE PERIMETER VOID FULL AND AIRTIGHT WITH AN <br />ACOUSTICAL SEALANT. <br />SEALANT: METACAULK 1000 BY RECTORSEAL <br />2. RECESSED LIGHT FIXTURES, JUNCTION BOXES, FIRE SPRINKLER PIPES, AND OTHER <br />PENETRATIONS MUST BE SEALED AIRTIGHT WITH ACOUSTICAL SEALANT. <br />E. BASEBOARD AND TRIM ATTACHMENT <br />1. DO NOT RIGIDLY ATTACH BASEBOARD OR OTHER FINISHING TRIM TO FRAMING THROUGH <br />RESILIENTLY SUSPENDED GYPSUM BOARD. <br />2. SCREW ATTACH BASEBOARD TO CHANNELS. GLUING BASEBOARD TO GYPSUM BOARD COULD <br />ALSO BE CONSIDERED. <br />151 ACOUSTO-PLUMB ISOLATION 1111 RESILIENT CHANNEL INSTALLATION GUIDE 17 <br />DWELLING SEPARATION NOTES <br />1.) PRIOR TO SETTING THE WALL PLATES INTO POSITION - THREE (3) CONTINUOUS <br />BEADS OF SEALANT SHALL BE LAID TO PROVIDE A SEAL BETWEEN THE FLOORING AND <br />THE PLATE. ALTERNATE MINIMUM 1/2" WIDE ACOUSTICAL TAPE, OR AMOFOAM SILL <br />SEALER. <br />2.) SEAL ALL ELECTRICAL OUTLET BOXES IN THE DWELLING SEPARATION WALL WITH <br />ACOUSTICAL SEALANT SO THAT THE BOXES ARE AIRTIGHT. <br />3.) COVER THE BACKS OF ALL ELECTRICAL OUTLET BOXES IN THE DWELLING <br />SEPARATION WALL WITH ACOUSTICAL OUTLET BOX PADS. <br />4.) OUTLET BOXES IN RATED ASSEMBLIES WITH BE STEEL PER U.B.C. SEC. 709.7 AND <br />710.2 OR APPROVED ALTERNATE. <br />5.) OUTLET BOXES BETWEEN UNITS TO BE STAGGERED WITH A 2'-0" MINIMUM SPACE <br />BETWEEN. <br />6.) FIRESTOPPING WILL OCCUR AT 10'-0" O.C. MAXIMUM, HORIZONTALLY AND <br />VERTICALLY. <br />7.) PENETRATIONS OR OPENINGS IN CONSTRUCTION ASSEMBLIES FOR PIPING, <br />ELECTRICAL DEVICES, RECESSED CABINETS, BATHTUBS, OR HEATING, VENTILATING OR <br />EXHAUST DUCTS SHALL BE SEALED, LINED, INSULATED, PADDED, OR OTHERWISE <br />TREATED TO MAINTAIN THE REQUIRED FIRE AND SOUND RATINGS. <br />8.) NO RIGID CONNECTION SHALL BE MADE BETWEEN CEILING GYPSUM BOARD AND <br />FLOOR JOIST OF FLOORS SEPARATING UNITS. <br />9.) PLUMBING, CONDUIT OR DUCTWORK SHALL BE HUNG FROM FLOOR JOISTS WITH <br />RESILIENT HANGERS AND SHALL NOT BE CONNECTED DIRECTLY TO CEILING IN ANY <br />MANNER. <br />10.) THE PERIMETER OF HARD SURFACED AREAS AND THEIR SETTING BEDS WILL BE <br />ISOLATED FROM WALLS WITH FIBERGLASS, FOAM, OR NEOPRENE GASKET AND CAULK TO <br />THE SURFACE. THE BASEBOARD SHALL COVER GAPS BUT WILL NOT TOUCH HARD <br />SURFACE. <br />11.) STUDS WILL BE WRAPPED WITH 5/8" TYPE "X" GYPSUM BOARD AT BEARING WALLS <br />WHERE DUCTS, WIRING, PLUMBING, ETC. PENETRATE WALL. <br />NOISE CONTROL GUIDELINES <br />FOR DOMESTIC PLUMBING <br />1. NOISE CONTROL APPLIES TO DOMESTIC SUPPLY AND RETURN PIPES (HOT AND COLD), <br />WASTE/DRAIN PIPES, AND INTERNAL ROOF OR PATIO DRAINS. (VENT PIPES DO NOT REQUIRE NOISE <br />CONTROL) <br />2. NOISE SENSITIVE ROOMS ARE DEFINED AS BEDROOMS, DENS AND LIVING/DINING ROOMS. <br />3. AVOID LOCATING MAJOR PIPES (I.E. RISERS AND OFFSETS) IN WALLS OR CEILINGS OF NOISE <br />SENSITIVE ROOMS. MAJOR PIPES SHOULD BE ROUTED THROUGH CORRIDORS, CLOSETS, OR <br />MECHANICAL CHASES. <br />4. PIPES IN WALL AND CEILING CAVITIES SHOULD BE TREATED AS FOLLOWS: <br />A.) PIPES MUST NOT BE RIGIDLY CONNECTED OR IN SOLID CONTACT WITH THE BUILDING <br />STRUCTURE. ISOLATE PIPES AS FOLLOWS: <br />B). FOR NOISE SENSITIVE ROOMS, POSITION PIPES NO CLOSER THAN 1-1/2" INCHES FROM <br />THE GYPSUM BOARD SURFACE. FOR ADDITIONAL PLUMBING NOISE CONTROL, APPLY A SECOND <br />LAYER OF GYPSUM BOARD. <br />C.) FOR NON -NOISE SENSITIVE ROOMS, POSITION PIPES NO CLOSER THAN 1" FROM THE <br />GYPSUM BOARD SURFACE. <br />D.) WALLS MUST BE SIZED TO ACCOMMODATE BOTH THE PIPE AND CLEARANCE TO <br />GYPSUM BOARD SURFACES; USE DOUBLE -STUD TYPE PARTITIONS FOR PLUMBING WALLS <br />WHEREVER POSSIBLE. PIPES THAT CROSS EACH OTHER WITHIN A WALL OR CEILING CAVITY MUST <br />ALSO BE TAKEN INTO CONSIDERATION WHEN SIZING WALLS AND CEILING SPACES. INCLUDE AN <br />ADDITIONAL 1/2" TO 1" THICKNESS TO ACCOUNT FOR ANY FIELD VARIATIONS. <br />E.) PENETRATIONS FOR PIPES THROUGH THE STRUCTURE (I.E. FLOOR SLAB, STUDS, OR <br />SOLID WALLS) SHOULD BE CUT OVERSIZED TO PREVENT CONTACT AND/OR TO ACCOMMODATE A <br />RESILIENT PIPE SLEEVE (ISOLATOR) AS REQUIRED TO SECURE PIPES IN PLACE. <br />F.) SUPPLY PIPES SERVING THE FIXTURE SIDE IN A PLUMBING WALL ARE NOT REQUIRED <br />TO MAINTAIN THE ABOVE SPECIFIED CLEARANCES. <br />G.) OPENINGS IN THE GYPSUM WALL BOARD AROUND A FIXTURE FEED LINE SHOULD BE <br />CUT OVERSIZED TO ACCOMMODATE A 1/4" BEAD OF CAULKING AROUND THE FEED LINE, THEREBY <br />ISOLATING THE PIPE FROM THE WALL. CAULKING WILL BE FIRE RATED. <br />H.) ISOLATORS CONSISTING OF RESILIENT PIPE SLEEVE ELEMENTS SHOULD BE USED IN <br />CONJUNCTION WITH OR INTEGRAL TO PIPE CLAMPS OR HANGERS WHEN SECURING PIPES TO THE <br />STRUCTURE. <br />I.) WHERE PIPES COME INTO INCIDENTAL CONTACT WITH THE BUILDING STRUCTURE OR <br />OTHER BUILDING ELEMENTS INCLUDING OTHER PIPES, A RESILIENT ISOLATOR SHOULD BE <br />INSTALLED AT THE POINT OF CONTACT. <br />J.) WHERE DOUBLE -STUD PLUMBING WALLS ARE USED, ROUTE AND SECURE PIPES THAT <br />SERVE A PARTICULAR UNIT TO THE STUD ROW THAT SUPPORTS THE GYPSUM BOARD OF THE <br />SAME UNIT. <br />K.) ACCEPTABLE ENGINEERED ISOLATORS AND ISOLATION SYSTEMS ARE AS FOLLOWS: <br />i.) FOR PIPES 1" OR LESS: ACOUSTO-PLUMB SYSTEM OF <br />SLEEVES AND CLAMPS (ORANGE AND BLUE) BY SPECIALTY <br />PRODUCTS, OR TRISOLATOR PIPE SLEEVES BY STONEMAN <br />COMPANY (OR EQUAL) INSTALLED IN CONJUNCTION WITH <br />STANDARD METAL PIPE CLAMPS AND HANGERS. <br />ii.) FOR PIPES LARGER THAN 1": TRISOLATOR PIPE SLEEVES <br />BY STONEMAN COMPANY (OR EQUAL) IN CONJUNCTION WITH <br />STANDARD METAL PIPE CLAMPS AND HANGERS, OR "FELT LINED <br />PIPE HANGERS" WITH A MINIMUM 1/4" THICK FELT. IF FELT <br />LINED HANGERS ARE USED, IT IS CRUCIAL THAT THE HANGERS <br />BE PROPERLY LOCATED AND SIZED SO THAT THE FELT IS NOT <br />CRUSHED OR OTHERWISE RENDERED INEFFECTIVE FOR <br />ISOLATING PIPE VIBRATION. <br />iii.) RISER CLAMPS SHOULD BE ISOLATED FROM THE BUILDING <br />STRUCTURE WITH 3/4" THICK 40 DUROMETER NEOPRENE <br />PAD BETWEEN THE RISER CLAMP EAR AND THE FLOOR SLAB. <br />5. USE CAST IRON DRAIN PIPES WHENEVER POSSIBLE. OTHERWISE, WRAP ALL PLASTIC AND <br />COPPER DRAIN PIPES THAT ARE LOCATED IN WALL OR CEILING CAVITIES OF DWELLING UNITS <br />COMPLETELY WITH PIPE WRAP TAPE BY LOWRY COMPANY. <br />6. INSTALL MINIMUM R-11 FIBERGLASS BATT INSULATION IN OTHERWISE UN -INSULATED WALL OR <br />CEILING CAVITIES WITH PLUMBING PIPES. <br />7. PACK THE CAVITY VOID BELOW TUBS AND SHOWERS WITH FIBERGLASS OR SPRAYED -ON <br />MATERIAL AND BLOCK THE BOTTOM OF THE TUBS. <br />8. FOR THE FLOOR/CEILING ASSEMBLIES AND WASTE LINES PENETRATIONS OF NON -COMMON <br />WALLS, WASTE LINES ABOVE THE SLAB SHALL BE CAST IRON. THE ELBOW BELOW THE STOOL <br />WASTE OUTLET SHOULD BE ISOLATED FROM THE POSITION BLOCKS WITH PADDING OF A FELT <br />MATERIAL. THE ENTIRE SPACE AROUND THE ELBOW MUST BE FILLED WITH FIBERGLASS OR EQUAL <br />MATERIAL. USE TRISOLATOR PIPE SLEEVES IN CONJUNCTION WITH STANDARD METAL PIPE <br />CLAMPS AND HANGERS, OR "FELT LINED PIPE HANGERS" WITH A MINIMUM 1/4" THICK FELT. IF FELT <br />LINED HANGERS ARE USED, IT IS CRUCIAL THAT THE HANGERS BE PROPERLY LOCATED AND SIZED <br />SO THAT THE FELT IS NOT CRUSHED, SKEWED, OR OTHERWISE RENDERED INEFFECTIVE FOR <br />ISOLATING PIPE VIBRATION. <br />9. WATER PRESSURE SHOULD BE CONTROLLED IN THE RANGE OF 35 TO 55 P.S.I. WATER VELOCITY <br />SHOULD NOT EXCEED 6 FEET / SEC. IF SINGLE FAUCET SYSTEM ARE USED. HOWEVER, THE CODE <br />ALLOWS 15 FEET/SEC. WHICH IS ACCEPTABLE IF NON -SINGLE FAUCET SYSTEM ARE USED. <br />SHOWER HEAD WATER FLOW RESTRICTIONS MUST BE USED TO LIMIT THE FLOW FOR LESS THAN 3 <br />GAL. / MIN. THE SHOWER HEAD IS TO INCORPORATE AN ACOUSTO-SCUTCHEON; HOWEVER, IF THE <br />SHOWER HEAD MUST BE RIGIDLY ATTACHED TO THE STRUCTURE, USE HUBBARD HOLDRITE <br />SILENCER #265 <br />10. THE PLUMBING SYSTEM MUST OTHERWISE BE INSTALLED PER THE PLUMBING CODE. WHERE A <br />CODE REQUIREMENT APPEARS TO CONTRADICT THE RECOMMENDED PIPE ISOLATION DETAILS, <br />THE CODE CONDITION SHOULD TAKE PRECEDENCE. CONFLICT SHOULD BE FULLY DOCUMENTED <br />AND BROUGHT TO THE ATTENTION OF THE DESIGN TEAM. <br />• <br />him <br />Architecture + Planning <br />17911 Von Karman Ave. <br />Suite 200 <br />Irvine, CA 92614 <br />ktgy.com <br />949.851.2133 <br />KTGY Project No: 2017-0934 <br />Project Contact: Debbie Holland <br />Email: dholland@ktgy.com <br />Principal: Wil Wong <br />Project Designer: D. Schoolmeester <br />Project Director: Debbie Holland <br />Developer <br />E D OAK <br />INV1'S"I'MEN i'S <br />4199 CAMPUS DRIVE <br />I RVI N E, CA 92612 <br />PHONE NO. (714) 342-2502 <br />O <br />04 <br />Q <br />U <br />Q <br />z <br />Q <br />z <br />Q <br />w <br />LJJ <br />ry <br />U) <br />w <br />r <br />LLO <br />06 <br />LO <br />No. Date Description H <br />W <br />�L-D <br />V ) <br />U <br />TW <br />1 <br />U <br />z <br />J <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />� <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />v J <br />ARCy1T <br />L.L <br />G��SED <br />�0� �0A <br />N <br />CV <br />No. C29795 <br />RENEWAL DATE <br />01.1 <br />AUGUST 31, 2023 <br />1 <br />qTF CF <br />C A�_ <br />License Stamp <br />o <br />ACOUSTICAL <br />ISOLATION DETAILS <br />16 <br />121 18 <br />NOTES <br />COPYRIGHT Cc <br />AD-2002 <br />