Laserfiche WebLink
STEEL BOXES ON THE OPPOSITE 4 <br />-- SIDES OF THE WALL SHALL BE <br />SEPARATED BY NOT LESS THAN 5 <br />24" WHERE THE WALL IS <br />CONSTRUCTED WITH INDIVIDUAL <br />NONCOMMUNICATING STUD <br />CAVITIES. <br />z <br />OR <br />BE SEPARATED BY A HORIZONTAL <br />N DISTANCE OF NOT LESS THAN THE <br />STUD CAVITY WHERE THE WALL w x <br />CAVITY IS FILLED WITH J Z <br />CELLULOSE LOOSE -FILL, x o <br />Z <br />5 ROCKWOOL OR SLAG MINERAL < <br />WOOL INSULATION.00 <br />ANNULAR SPACE, TYPICAL FLILL <br />SEE CBC SECTION 714.3.2 <br />TWO LAYERS OF 5/8" TYPE <br />ONE LAYER OF 5/8" TYPE <br />(2) LAYERS OF 5/8" TYPE 'X' <br />ONE LAYER OF 5/8" TYPE <br />'X' GYPSUM BOARD EACH <br />'X' GYPSUM BOARD EACH <br />GYPSUM BOARD EACH <br />'X' GYPSUM BOARD EACH <br />STEEL OR LISTED BOXES ON THE <br />SIDE <br />SIDE <br />SIDE <br />SIDE <br />OPPOSITE SIDES OF THE WALL <br />SHALL BE SEPARATED BY SOLID <br />� 3-5/8" STEEL STUDS <br />3-5/8" STEEL STUDS <br />2X4 WOOD STUDS 16" O.C. OR <br />2X WOOD STUDS <br />FIREBLOCKING IN ACCORDANCE <br />24" O.C. <br />24" O.C. <br />2X6 WOOD STUDS 24" O.C. <br />16" O.C. <br />4 WITH CBC SECTION 714.3.2.1. <br />OR <br />5 BE SEPARATED BY PROTECTING 4 <br />BOTH BOXES WITH LISTED PADS. <br />3-1/2" GLASS FIBER <br />WALL INSULATION WHERE <br />WALL INSULATION WHERE <br />WALL INSULATION WHERE <br />OR <br />INSULATION <br />REQUIRED <br />REQUIRED <br />REQUIRED <br />BE SEPARATED BY OTHER LISTED <br />MATERIALS AND METHODS. ILL <br />TYPICAL SINGLE STUD WALL OR PARTITION <br />ASSEMBLY COMPLIES WITH: <br />ASSEMBLY COMPLIES WITH: <br />ASSEMBLY COMPLIES WITH: <br />ASSEMBLY COMPLIES WITH: <br />GA FILE No. WP 1522, <br />GA FILE No. WP 1072, STC 45-49 <br />GA FILE No. WP 4136, WP 4230 <br />GA FILE No. WP 3520 <br />6 DOUBLE STUD RATED FIRE <br />STC 55-59 (REQ. MIN. STC 50) <br />CBC TABLE 721.1 (2) ITEM No. 13-1.1 <br />CBC TABLE 721.1 (2) ITEM No. 14-1.3 <br />CBC TABLE 721.1 (2) ITEM No. 14-1.3 <br />PARTITION <br />N THE <br />STEEL O ESI ED BOXESSOFTH WALL <br />OPPOSITE SIDES OF THE WALL SHALL <br />21 <br />2-HR RATED METAL FRAMED WALL <br />13 <br />1-HR RATED METAL FRAMED WALL <br />9 <br />2-HR RATED WOOD FRAMED WALL <br />5 <br />1-HR RATED WOOD FRAMED WALL <br />1 <br />BE SEPARATED BY PROTECTING BOTH <br />BOXES WITH LISTED PADS. <br />or <br />BE SEPARATED BY OTHER LISTED <br />MATERIALS AND METHODS. <br />1/8" MAX <br />5 <br />TWO LAYERS OF 5/8" TYPE <br />ANNULAR SPACE, TYPICAL SEE CBC <br />'X' GYPSUM BOARD <br />INTERIOR EXTERIOR <br />3 SECTION 714.3.2 <br />DOUBLE STUD WALL OR PARTITION (SIMILAR FOR STAGGERED STUDS) <br />RATED FIRE PARTITION <br />NOTES: <br />3-1/2" SOUND ATTENUATION BLANKET <br />1. DEPTH OF ELECTRICAL BOXES SHALL BE COMPATIBLE WITH WALL OR PARTITION STUD SIZE AND <br />ACCOMMODATE LISTED PADS WHEN USED. <br />UNIT UNIT <br />2. ALL UNUSED KNOCK -OUTS SHALL BE PLUGGED. <br />3. CONDUIT SHALL BE INSTALLED ON THE SIDE SERVED IN DOUBLE STUD OR STAGGERED STUD <br />`` 2-1/2" C-T, C-H OR I STEEL STUDS IN <br />ONE LAYER OF 5/8" TYPE <br />MINERAL OR GLASS FIBER BATT <br />NNU <br />WALLS AND PARTITIONS. CONDUIT IS NOT ALLOWED IN THE AIR SPACE BETWEEN STUD ROWS. <br />2-1/2" FLOOR AND CEILING RUNNERS <br />X' GYPSUM BOARD <br />INSULATION STUFFED IN THE AIR <br />EXTERIOR PLASTER <br />4. SEPARATE CONDUIT SHALL BE PROVIDED FOR ELECTRICAL BOXES ON OPPOSITE SIDES OF SINGLE <br />SPACE AND STAPLED TO STUDS AT <br />VVVW <br />STUD ACOUSTIC WALLS OR PARTITIONS. <br />10'-0" O.C. HORIZONTALLY <br />SHEAR PANEL WHERE OCCURS <br />5. CONTRACTOR SHALL DRILL ALL STUD AS REQUIRED FOR INSTALLATION OF CONDUIT. <br />1"X24" PROPRIETARY TYPE X <br />3-5/8" STEEL STUDS <br />6. LISTED PAD WRAPS ARE REQUIRED ON ALL ELECTRICAL BOXES AT ALL WALLS AND PARTITIONS <br />GYPSUM PANEL <br />24" O.C. <br />2x4 WOOD STUD 16" O.C. <br />THAT REQUIRE ACOUSTICAL INSULATION. SEE ACOUSTICAL REPORT FOR ADDITIONAL <br />STAGGERED 8" O.C. FROM <br />REQUIREMENTS. <br />OPPOSITE SIDE <br />MEMBRANE PENETRATIONS SHALL BE INSTALLED PER CBC SECTION 714.3.2. WHERE WALLS OR <br />TWO LAYERS OF 5/8" <br />GLASS FIBER <br />OPTIONAL ION2ND 3LAN SOUND <br />ATTENUATION BLANKET <br />PARTITIONS ARE REQUIRED TO HAVE A FIRE -RESISTIVE -RATING, RECESSED FIXTURES SHALL BE <br />PROPRIETARY TYPE X <br />INSULATION <br />INSULATION <br />(1) LAYER 5/8" TYPE X GYPSUM BOARD <br />INSTALLED SUCH THAT THE REQUIRED FIRE -RESISTANCE WILL NOT BE REDUCED. <br />WALLBOARD <br />EACH SIDE <br />MEMBRANE PENETRATION OF MAXIMUM 2-HOUR FIRE -RESISTANT -RATED WALLS AND PARTITIONS ARE <br />ALLOWED BY STEEL ELECTRICAL BOXES THAT DO NOT EXCEED 16 SQUARE INCHES IN AREA, PROVIDED <br />SOUND INSULATION IN BOTH WALL <br />THE AGGREGATE AREA OF THE OPENINGS THROUGH THE MEMBRANE DOES NOT EXCEED 100 SQUARE <br />CAVITIES PER T-24 REQUIREMENTS <br />INCHES IN 100 SQUARE FEET. MEMBRANE PENETRATIONS BY LISTED ELECTRICAL BOXES OF ANY <br />PROPRIETARY GYPSUM BOARD: <br />ASSEMBLY COMPLIES WITH: <br />MATERIAL ARE ALLOWED, PROVIDED SUCH BOXES HAVE BEEN TESTED FOR USE IN <br />5/8" GOLD BOND FIRE -SHIELD <br />GA FILE No. WP 3380 <br />FIRE -RESISTANCE -RATED ASSEMBLIES AND ARE INSTALLED IN ACCORDANCE WITH THE INSTRUCTIONS <br />INCLUDED WITH THE LISTING. <br />ASSEMBLY COMPLIES WITH: 1" GOLD BOND FIRE SHIELD SHAFTLINER <br />ASSEMBLY COMPLIES WITH: <br />CBC TABLE 721.1 (2) ITEM No. 15-1.3 <br />UL DESIGN U305 <br />GA FILE No. WP 7076 <br />GA FILE No. WP 1052, WP 1350 <br />CA NOISE CONTROL FILE No.1.2.3.1.4 <br />THE ANNULAR SPACE BETWEEN THE WALL MEMBRANE AND THE STEEL OR LISTED BOX SHALL NOT <br />UL DESIGN U497 <br />MIN. STC 50 <br />MIN. STC 50 <br />EXCEED 1/8". <br />22 <br />OUTLET PENETRATION <br />18 <br />2-HR RATED SHAFT WALL <br />14 <br />1-HR RATED METAL FRAMED WALL <br />10 <br />FIREBLOCKING @PARTY WALL <br />6 <br />1-HR RATED WALL @ CORRIDOR <br />2 <br />WALL TO FLOOR JOINT ISOLATION <br />1/2" GAP PROVIDE BACKING FOR CARPET <br />CONTINUE GYPSUM BOARD BEHIND <br />AND BELOW STAIR AS REQUIRED TO <br />MAINTAIN FIRE AND/OR ACOUSTIC <br />, <br />RATED WALL ASSEMBLIES <br />A <br />STRINGERS SHALL HAVE NO <br />CONNECTION TO WALL <br />` 5/8" TYPE X GYPSUM WALLBOARD AT <br />TWO LAYERS OF 5/8" <br />" <br />TWO LAYERS OF 5/85/8"TYPE <br />TWO LAYERS OF 5/8" TYPE <br />ONE LAYER OF 5/8" TYPE <br />ENCLOSED SPACE UNDER STAIRS <br />PROPRIETARY TYPE'X' GYPSUM <br />PROPRIETARY 'GYPSUM <br />'X' GYPSUM BOARD EACH <br />'X' GYPSUM BOARD EACH <br />BOARD EACH SIDE <br />BOARD <br />SIDE <br />SIDE <br />3-5/8" 18 GAGE STEEL STUDS 16" O.C. <br />3-5/8" 18 GAGE STEEL STUDS 16" O.C. <br />STRUCTURAL SHEATHING <br />STRUCTURAL SHEATHING <br />DOUBLE ROW MIN. 1" APART. <br />DOUBLE ROW MIN. 1" APART. <br />WHERE OCCURS <br />WHERE OCCURS <br />LATERAL BRACING ON BOTH SIDES OF <br />LATERAL BRACING ON BOTH SIDES OF <br />1 16 <br />a <br />THE WALL NOT LESS THAN 5 FEET ON <br />THE WALL NOT LESS THAN 5 FEET ON <br />CENTER VERTICALY. <br />CENTER VERTICALY. <br />2X WOOD STUDS <br />2X WOOD STUDS <br />3-1/2" GLASS FIBER INSULATION ON <br />3-1/2" GLASS FIBER INSULATION ON <br />16" O.C. ON SEPARATE <br />16" O.C. ON SEPARATE <br />BOTH SIDES IN CAVITY <br />BOTH SIDES IN CAVITY <br />PLATES 1" APART <br />PLATES 1" APART <br />WALL INSULATION IN BOTH <br />WALL INSULATION IN BOTH <br />STUD CAVITIES <br />STUD CAVITIES <br />ASSEMBLY COMPLIES WITH: <br />PROPRIETARY GYPSUM BOARD: <br />ASSEMBLY COMPLIES WITH: 5/8" SHEETROCK FIRECODE <br />GA FILE No. WP 5060 <br />PROPRIETARY GYPSUM BOARD: <br />ASSEMBLY COMPLIES WITH: 5/8" SHEETROCK FIRECODE <br />GA FILE No. WP 5006 <br />ASSEMBLY COMPLIES WITH: <br />GA FILE No. WP 5520 <br />GA FILE No. WP 3370 <br />UL DESIGN U305 <br />UL DESIGN U493 <br />UL DESIGN U493 <br />UL R4024 <br />CA NOISE CONTROL FILE No.1.2.4.1.5.4 <br />MIN. STC 50 <br />MIN. STC 50 <br />MIN. STC 50 <br />MIN. STC 50 <br />23 <br />STAIR PARTY WALL <br />19 <br />2-HR RATED MTL. PARTY WALL, <br />15 <br />1-HR RATED METAL PARTY WALL <br />11 <br />2-HR RATED PARTY WALL <br />7 <br />1-HR RATED PARTY WALL <br />3 <br />LAYER OF 5/8" TYPE 'X' <br />I IV <br />GYPSUM BOARD <br />PLUMBING WALL WHERE <br />MOISTURE RESISTANT GYPSUM <br />OCCURS <br />BOARD, NON -PAPER BACKED, <br />CONTINUES BEHIND THE <br />2X CORRIDOR FLOOR FRAMING <br />° <br />UNIT <br />RATED WALL PARTITION <br />TUB/SHOWER UNIT <br />PERPENDICULAR TO THE RATED WALL <br />° <br />° ° - <br />2X W <br />WOOD OR METAL <br />I <br />MOISTURE RESISTANT GYPSUM <br />° <br />STUDS <br />BOARD, NON PAPER BACKED OVER/77° <br />TUB/SHOWER FLANGE <br />a ° a <br />° ` <br />° <br />PLUMBING PIPE SUPPORT <br />2x3 OR 2x4 FLAT WOOD STUDS 24" O.C. <br />° ° ° ° a <br />CLAMPS TO BE MIN. 1/2" <br />\ RESILIENT CAULK <br />CONTINUE GYPSUM BOARD BEHIND <br />° <br />a d ° ° <br />FROM GYPSUM WALL BOARD <br />5/8" TYPE X GYP. BOARD BOTH SIDES <br />THE LEDGER TO MAINTAIN WALL FIRE <br />Q <br />2X BLOCKING <br />y <br />RATING. <br />a <br />I <br />;- TUB, ISOLATE BASE FROM <br />01 <br />a <br />- <br />RECESSED OPENINGS IN ONE HOUR <br />WALLS FOR MEDICINE CABINETS, FIRE <br />EXTINGUISHERS, ELECTRICAL PANELS <br />\ <br />FLOOR AND WALL <br />\ 2X LEDGER OVER GYPSUM BOARD <br />I OR ANY OTHER FIXTURE EXCEEDING 16 <br />SQ. INCHES SHALL BE LINED WITH 5/8" <br />MAINTAIN FIRE RATING OF WALL <br />ONE LAYER OF GYPSUM <br />WALL BOARD <br />_ _ _ _ _ _ _ _ _ <br />J <br />I TYPE X GYP. BOARD ON ALL SIDES. <br />I TAPE JOINTS <br />ASSEMBLY <br />Q <br />3-5/8" STEEL STUDS <br />LW <br />DROPPED SOFFIT WHERE OCCURS <br />Q <br />CONTINUE FLOOR TOPPING <br />, ' <br />VARIES <br />SEE PLAN <br />UNDER TUB <br />WALL INSULATION WHERE <br />` <br />— — <br />REQUIRED <br />BATT INSULATION, EXTEND <br />— <br />TWO STUD CAVITIES ON <br />Yl— <br />EITHER SIDE OF PLUMBING <br />ASSEMBLY COMPLIES WITH: <br />GA FILE No. WP 3640 <br />UL DESIGN U336 <br />24 <br />TUB / SHOWER WALL <br />20 <br />SHAFT WALL CORRIDOR <br />16 <br />FURRED WALL CONC. WALL <br />12 <br />PLUMBING WALL <br />8 <br />1-HR RATED RECESS <br />4 <br />Architecture + Planning <br />17911 Von Karman Ave. <br />Suite 200 <br />Irvine, CA 92614 <br />ktgy.com <br />949.851.2133 <br />KTGY Project No: 2017-0934 <br />Project Contact: Debbie Holland <br />Email: dholland@ktgy.com <br />Principal: Wil Wong <br />Project Designer: D. Schoolmeester <br />Project Director: Debbie Holland <br />Developer <br />ED7 OAK <br />INVESTMENTS <br />S <br />4199 CAMPUS DRIVE <br />IRVINE, CA 92612 <br />PHONE NO. (714) 342-2502 <br />T_ <br />C) <br />N <br />Q <br />U <br />Q <br />z <br />Q <br />Q <br />z <br />Q <br />U) <br />I- <br />w <br />w <br />CO <br />LU <br />T_ <br />LO <br />06 <br />No. Date Description <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />c,k AR pyx, <br />�0 ���A <br />No. C29795 <br />RENEWAL DATE <br />AUGUST 31, 2023 <br />�F C A� <br />License Stamp <br />FIRE -RATED INTERIOR <br />WALL ASSEMBLIES <br />AD-22 <br />Z <br />^J <br />U) <br />1r n <br />0. <br />L.L <br />N <br />C) <br />1 <br />r <br />C) <br />00 <br />C) <br />COPYRIGHT (c <br />