NO OPENING IN THE ROOF WITHIN CL FIRE WALL <br />NO OPENING IN THE ROOF WITHIN <br />STRUCTURAL PANEL <br />4 FEET OF THE FIREWALL <br />4 FEET OF THE FIREWALL <br />WHERE OCCURS <br />� <br />LINE OF SOFFIT ABOVE <br />FIRE -RETARDANT -TREATED ROOF <br />SHEATHING FOR 4 FEET OF THE FIREWALL FIRE ALL <br />WIDTH <br />FIRE -RETARDANT -TREATED ROOF <br />SHEATHING FOR 4 FEET OF THE <br />ON BOTH SIDES OF THE WALL <br />� <br />FIREWALL ON BOTH SIDES OF THE WALL <br />O <br />3 HOUR FIRE RATED WALL <br />O <br />- <br />2-1/2" <br />METAL C-H STUDS, 25 GAGE WITH 1"X24" PROPRIETARY <br />ZEZ <br />GYPSUM <br />LINER BOARD INSTALLED INTO C-H STUDS <br />METAL STUD FRAMING. INSTALL 0/ <br />GYPSUM WALLBOARD. <br />THREE <br />3 LAYERS %" THICK PROPRIETARY TYPE X GYPSUM <br />) <br />BOARD <br />ON OPPOSITE SIDE <br />AAAA/V <br />/VW T <br />C4 <br />O <br />PROPRIETARY <br />GYPSUM BOARD: <br />RATED INTERIORRID R <br />CO0 0 <br />8" SHEETROCK FIRECODE C GYPSUM PANELS <br />WALL PER DETAIL <br />1" SHEETROCK GYPSUM LINER PANELS <br />J <br />a <br />� ' <br />o <br />6H6M6 <br />2 <br />O <br />MX6 <br />O NON -RATED WALL <br />/ <br />3-HOUR RATED DOOR, INSTALL PER z <br />YE <br />ONE LAYER Y8" TYPE "X" GYPSUM BOARD ON 2X4 <br />MANUFACTURERS INSTRUCTIONS. <br />Cam' <br />WOOD STUDS ON SILL PLATE <br />BATT <br />INSULATION IN WALL CAVITY <br />_7 <br />ALUMINUM BREAKAWAY <br />DOOR SWING <br />CLIPS ON BOTH SIDES OF <br />THE WALL <br />FILL OVERFRAMING <br />ATTIC INSULATION <br />PER ENERGY REPORT. <br />PROVIDE FIREBLOCKING <br />1 <br />SEALANT AT DRYWALL AND JAMB. / <br />DOOR HEAD <br />CAVITY WITH INSULATION <br />ASSEMBLY COMPLIES WITH: IN WALL CAVITIES <br />GA FILE No. WP 7453 <br />UL DESIGN U415 - SYSTEM <br />G <br />RATED ROOF / CEILING <br />I <br />ASSEMBLY <br />� <br />FIREBLOCKING IN WALL CAVITY <br />4 FEET MINIMUM EXTENT OF FIRE -RETARDANT <br />TREATED PLYWOOD @ FLR/CLG ASSEMBLIES ON <br />3-HR RATED FIRE WALL <br />1 <br />PER CBC SECTION 718. <br />EACH SIDE OF <br />FIREWALL. TYP. <br />I— <br />BASEBOARD AS <br />UNIT <br />UNIT <br />SCHEDULED <br />FIRE -RETARDANT TREATED <br />SHEATHING <br />TYPICAL RATED <br />MAINTAIN CLEARANCE <br />FLOOR/CEILING <br />BETWEEN BASEBOARD <br />/ 9 <br />FIRE RETARDANT <br />AND FINISH FLOOR CAULK <br />Hl <br />3-HOUR RATED FIRE <br />TREATED <br />GAP WITH ACOUSTICAL <br />SEALANT <br />WALL PER DETAIL / <br />° <br />SHEATHING <br />RATED INTERIOR CORRIDOR WALL PER <br />° <br />FINISH FLOOR <br />x <br />xxx <br />/ DETAIL <br />-PERIMETER ISOLATION <br />MATERIAL (CLOSED CELL <br />FOAM, 1/4" MIN.) <br />7APPROVED <br />1 HOUR <br />o <br />/ <br />ACOUSTICAL SEALANT <br />U.L. FIRE RESISTIVE <br />ALUMINUM BREAKAWAY <br />JOINT SYSTEM <br />REQUIRED AT <br />CLIPS <br />BOTH SIDES OF <br />/I <br />INSTALL MAGNETIC DOOR HOLD OPEN <br />WALL <br />k <br />DEVICE ON SHIM AS NECESSARY FOR <br />El <br />yy <br />DOOR FACE TO FLUSH W/ WALL FINISH <br />2X WOOD STUDS <br />AS SHOWN. TYP. <br />BREAKAWAY CLIPS TYP. <br />HOLD CEILING GYPSUM <br />ONE HOUR EXT. <br />LINE OF SOFFIT ABOVE <br />BOARD BACK 1/4", CAULK <br />WALL ASSEMBLY <br />AIRTIGHT WITH 1-HOUR <br />C* <br />PER DETAIL <br />FIRE RATED ACOUSTICAL <br />2/AD-22 <br />SEALANT PRIOR TO TAPE <br />SHEAR PANEL AS <br />3 HOUR FIRE RATED SHAFT WALL SYSTEM, TYPICAL <br />UNIT <br />AND MUD <br />OCCURS SEE STRL. <br />NON RATED FURRED WALL, <br />FIRE -RATED SEALANT <br />RATED FIRE WALL <br />TYPICAL <br />AT PENETRATION <br />TYP. <br />3 HR. FIRE <br />BATT <br />° <br />RATED <br />FLOOR/CEILING <br />WALL ASSEMBLY <br />PER <br />DETAIL <br />INSULATION <br />3-HR RATED <br />DOOR AT FIRE WALL <br />18 <br />3-HR <br />RATED <br />F.W. @ FLR/CLNG <br />6 <br />3-HR <br />F.W. <br />@ EXT. WALL <br />2 <br />FRAMING PARALLEL <br />FRAMING PERPENDICULAR <br />TYPICAL RATED CORRIDOR <br />EXTERIOR <br />FLOOR <br />/CEILING PER DETAIL <br />3-HOUR RATED <br />FIRE WALL~✓ <br />SHEAR PANEL WHERE <br />XHI <br />OCCURS <br />z <br />J <br />INTERIOR WALL <br />NO RIGID CONNECTION <br />BETWEEN STUD WALLS <br />a <br />FIRE -RETARDANT <br />TREATED SHEATHING <br />RATED INTERIOR CORRIDOR <br />WALL PER DETAIL <br />r '//V <br />U <br />UNIT <br />UNIT <br />UNIT <br />LAYER OF GYP. BOARD <br />CONTINUOUS TO <br />UNDERSIDE OF FLOOR <br />SET SILL PLATES ON (3) <br />HOLD GYP. BD. %" AWAY FROM <br />SHEATHING <br />CONT. BEADS OF SEALANT <br />ADJACENT GYP. BD. AND WOOD <br />FRAMING. <br />25 GA. GALV. STL. TRACK, <br />° <br />° <br />° <br />LU <br />TOP & BOTTOM <br />a ° <br />a <br />° ° °� a ° <br />° <br />° ° a ° ° a <br />° <br />3 HOUR FIRE WALL <br />3-HOUR RATED DOOR & FRAME, <br />° ° a ° <br />4 <br />UNIT <br />ASSEMBLY PER DETAIL <br />INSTALL PER MANUFACTURERS <br />DOOR IN OPEN <br />a <br />INSTRUCTIONS. <br />POSITION, BEYOND <br />° a ° ° <br />° <br />a <br />Z' ' - <br />° <br />° <br />< <br />3 HR. <br />FIRE <br />1 <br />SEE DETAIL # 2 FOR <br />BATT INSULATION <br />WALL ASSEMBLY PER DETAIL <br />INFORMATION NOT SHOWN <br />3-HR RATED <br />DOOR <br />HEAD <br />19 <br />3-HR RATED FIRE WALL SECTION <br />11 <br />3-HR <br />F.W. @ <br />EXT. WALL <br />7 <br />3-HR <br />F.W. <br />@ I NT. WALL <br />3 <br />7Tx <br />MOISTURE RESISTANT NON -PAPER <br />3-HOUR RATED FIRE <br />BACKED GYPSUM BOARD <br />WALL PER DETAIL <br />2X BLOCKING <br />3-HOUR STEEL DOUBLE <br />RESILIENT CAULK <br />3-HOUR RATED FIRE <br />EGRESS JAMB <br />WALL PER DETAIL <br />UNIT <br />FIBERGLASS TUB <br />KD <br />25 GA. GALV. STL. TRACK <br />FILL VOID WITH INSULATION <br />KD <br />/ <br />FULL HEIGHT <br />z <br />( <br />a <br />a a <br />/ <br />SEMI -CONCEALED HINGE <br />Q <br />a a <br />o / <br />Q <br />i <br />v v <br />EDGE OF SLAZB <br />a <br />DOOR SWING <br />a <br />a<1 <br />a <br />a <br />��- <br />a <br />a <br />LINE OF SOFFIT ABOVE <br />77 <br />4 a <br />a <br />3-HOUR METAL DOOR <br />STAIR / MECHANICAL <br />777777 <br />SHAFT <br />SEE DETAIL # 1 FOR <br />INFORMATION NOT SHOWN <br />RATED FLOOR / CEILING <br />3-HR RATED <br />DOORJAMB <br />24 <br />3-HR RATED <br />DOORJAMB <br />20 <br />16 <br />12 <br />3-HR <br />F.W. @SHAFT <br />g <br />3-HR <br />FIRE WALL @TUB <br />4 <br />Architecture +Planning <br />17911 Von Karman Ave. <br />Suite 200 <br />Irvine, CA 92614 <br />ktgy.com <br />949.851.2133 <br />KTGY Project No: 2017-0934 <br />Project Contact: Debbie Holland <br />Email: dholland@ktgy.com <br />Principal: Wil Wong <br />Project Designer: D. Schoolmeester <br />Project Director: Debbie Holland <br />Developer <br />E I] Q A K <br />INVESTMENTS <br />4199 CAMPUS DRIVE <br />I RVI N E, CA 92612 <br />PHONE NO. (714) 342-2502 <br />N TF <br />T_ <br />0 <br />N <br />Q <br />U <br />Q <br />z <br />Q <br />Q <br />z <br />Q <br />C) <br />F_ <br />w <br />w <br />C) <br />w <br />L0 <br />06 <br />T_ <br />No. Date Description <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />��SED ARCy�l <br />No. C29795 <br />RENEWAL DATE <br />AUGUST 31, 2023 <br />�F CAS\ <br />License Stamp <br />3-HR RATED FIRE <br />WALL DETAILS <br />AD-25 <br />C) <br />CV <br />1 <br />Ir— <br />C) <br />00 <br />0 <br />COPYRIGHT U <br />