EGRESS OPENING WIDTH <br />TOTAL OCCUPANTS <br />54 <br />EGRESS WIDTH PER OCCUP <br />0.2 <br />REQUIRED OPENING WIDTH <br />10.8" <br />PROPOSED OPENING WIDTH <br />MIN. 33.4" <br />PROPOSED DOOR WIDTH <br />36" <br />EGRESS OPENING WIDTH <br />TOTAL OCCUPANTS <br />31 <br />EGRESS WIDTH PER OCCUP <br />0.2 <br />REQUIRED OPENING WIDTH <br />6.2" <br />PROPOSED OPENING WIDTH <br />MIN. 33.4 <br />PROPOSED DOOR WIDTH <br />36" <br />STAIR WIDTH <br />TOTAL OCCUPANTS <br />31 <br />EGRESS WIDTH PER OCCUP <br />0.3 <br />REQUIRED STAIR WIDTH <br />9.3" <br />PROPOSED STAIR WIDTH <br />48" <br />EGRESS OPENING WIDTH <br />TOTAL OCCUPANTS <br />46 <br />EGRESS WIDTH PER OCCUP <br />0.2 <br />REQUIRED OPENING WIDTH <br />9.2" <br />PROPOSED OPENING WIDTH <br />MIN. 33.4" <br />PROPOSED DOOR WIDTH <br />72" <br />EGRESS OPENING WIDTH <br />TOTAL OCCUPANTS <br />EGRESS WIDTH PER OCCUP <br />0.2 <br />REQUIRED OPENING WIDTH <br />44.6" <br />PROPOSED OPENING WIDTH <br />MIN. 33.4" <br />PROPOSED DOOR WIDTH <br />48" <br />EXIT <br />DISCF,IAE <br />I <br />EGRESS OPENING WIDTH <br />EGRESS OPENING WIDTH <br />TOTAL OCCUPANTS <br />31 <br />EGRESS WIDTH PER OCCUP <br />0.2 <br />REQUIRED OPENING WIDTH <br />6.2" <br />PROPOSED OPENING WIDTH <br />MIN. 33.4" <br />PROPOSED DOOR WIDTH <br />36" <br />L= 21'- 1 <br />TUR <br />' AR ND <br />---, I I r--- - ---, POT <br />I I I I I II I 1 <br />eoe°ooe°ooeocoeoe°eoe°ooeoco e <br />I I I I ❑ I eoseveve°e°e°e°e°e°c°e°e°e°e°�o° <br />I i i i i o0000000000000000000 0 <br />I I ?------o°o°o°o°o°o o° <br />-------+------------------------- 1-------- +------ ---------- -------------------------- +------ - ----- <br />oeo%% I I I 161'-101, 1 <br />-J L____ _ __J L_- 1/3 OVERALL -- ----- <br />0000 <br />I MENSION =642"- <br />I oe°coe°o <br />eeeo <br />FIRE PUMP <br />ROOM <br />I <br />�r Et (1(ICTFR PI�" <br />__- <br />EGRESS OPENING WIDTH <br />TOTAL OCCUPANTS <br />30 <br />EGRESS WIDTH PER OCCUP <br />0.2 <br />REQUIRED OPENING WIDTH <br />6" <br />PROPOSED OPENING WIDTH <br />MIN. 33.4" <br />PROPOSED DOOR WIDTH <br />36" <br />EXIT <br />nierunar_G <br />EGRESS OPENING WIDTH <br />TOTAL OCCUPANTS <br />42 <br />EGRESS WIDTH PER OCCUP <br />0.2 <br />REQUIRED OPENING WIDTH <br />8.4" <br />PROPOSED OPENING WIDTH <br />MIN. 33.41, <br />PROPOSED DOOR WIDTH <br />36" <br />EGRESS OPENING WIDTH <br />TOTAL OCCUPANTS <br />83 <br />EGRESS WIDTH PER OCCUP <br />0.2 <br />REQUIRED OPENING WIDTH <br />16.6" <br />PROPOSED OPENING WIDTH <br />MIN. 33.4" <br />PROPOSED DOOR WIDTH <br />36" <br />oe°ooe°o I � - <br />o°e°o°e° <br />1 1 <br />1 <br />-- ---� L---- <br />00 ° <br />oo° o000 <br />000 <br />TU -AR ND <br />00%oo°SP <br />I I I <br />oe°ooe°o 1 1 <br />cee°e°oo <br />00000000 <br />7-T <br />eee°eeeo <br />1 I 1 <br />L---------J L---- <br />o°o°o°o° <br />EXIT <br />c°e°e°e° <br />o000 <br />I31 <br />UP 5% I °o°°o°°o°°o° <br />0000 <br />II0000 <br />' I o000 1 <br />I / o000 <br />30 ic <br />----- ----- I - `-- 1 I <br />1 <br />I II R�u� 1 <br />I I BIKE STORAGE ¢ ® 1 <br />-- r------- 1-, r----- ---, 437 300----I--F, <br />I I I I I ---- I I 2 S-2 1 i 1 1 <br />---------------------------------- - ----------------- <br />I 1 <br />I I " <br />----- <br />L_______1_J I I L___ '_' ___J / I __J L------ i__� J L <br />I I I '� F�qle - 1 <br />- - - - - - - - - - - ; �� sy°�F %, <br />a I� I I� I I� o I F,Q9C�� 0.9�0�� J ❑ 1 <br />--------------------- ------ - <br />- <br />°% SFA�F Ftis� <br />� � T�O <br />I <br />�030 <br />I <br />I <br />I. <br />- <br />IC,, <br />1 <br />700� SST r-- I- ---1 r--------, <br />IILJII I ; I I I I • J <br />1I/p� <br />VAI I I <br />i <br />Ll <br />I m� - I ----c <br />i I I i i i o>oo>o> 000>o ® i I i I -! -- - -- <br />I I I I I ❑ I I I I I I I e°O°e°O°O°O°O°e°O°e°e°O°e I I <br />--- ----- , i i i i i i i o00000000000000000000000000o 1 i <br />I I I I o00000000000000000000000e000 I 1 1 1 ; 1 <br />DWELLING UNIT <br />1286 <br />1 200 <br />7 <br />R-2 <br />ELECTRICAL RM <br />338 300 <br />2 R-2 <br />■■- FIRE WALL <br />PARKING <br />- <br />I1 <br />17602 1 200 <br />j <br />a1 <br />89 1 S-2I <br />Iff <br />IT <br />TOTAL PARKING OCCUPANT LOAD = 92 <br />I <br />I <br />I <br />r <br />6 <br />R-2 <br />92 OCCUPANTS/3 EXITS =30/31 OCC. PER EXIT <br />I <br />C <br />1 <br />L A <br />I <br />(�» <br />UP <br />1 <br />1 <br />1 <br />eoeoeoeoe <br />00000000 <br />eeee � <br />00 °00% <br />L <br />1 <br />I I <br />I <br />I <br />o00000 0 <br />1 <br />I <br />I <br />r----,---� r ---------- <br />, r --- <br />----, <br />1 ----+--------- --------------------------- +----- -- <br />------+------------------------- <br />0000 <br />L- <br />00 00000 00000 0000000 °.- o°000000 00000000000000000000 000000000 <br />I , , I , oo° o%000%° o %0000° ooe o0000000000%00' 00000%00%° 0000000000000000000000000000%%00%00%00 000° °000%00%°o°o - - <br />- fi fi - � - - - - - - - - - � - � I I I I °eoeo°%oe°,e% o°oe° ,eoeoe oeo°o°oeo°oeo% o, oe%o0oe%°�eo°oeoeo°oeo°oeo°oeoeo°oeo°oeo°%oeoeo°o°%%e%oe, °°°°%< I � L - 1 '-1 " aJ ah <br />I i I i i I i I I I i I 1 <br />I I I I 1 1 1 i i I I nj I I l, 1 <br />DN 4El <br />.5% I 1� I I I I �`Z` / PARCEL ----- ❑❑ ____ <br />TRASH / 1 i r\^ O !`�5r\r� r-- -- --- ROOM - <br />---- - LOADING 1 r�to' �p� I I <br />r-� I r---r-----� 1 1 ,o �o O ,�o I I <br />EGRESS OPENING WIDTH <br />TOTAL OCCUPANTS <br />43 <br />EGRESS WIDTH PER OCCUP <br />0.2 <br />REQUIRED OPENING WIDTH <br />8.6" <br />PROPOSED OPENING WIDTH <br />MIN. 33.4" <br />PROPOSED DOOR WIDTH <br />36" <br />I I ,, I TOTAL OCCUPANT LOAD - 127 <br />I 1tET = 0 0 0 0 �o� -1 t�,C' I I <br />1 _ _ I O O g 1 _-_ 127 OCCUPANTS/3 EXITS =42/43 OCC. PER EXIT <br />-- _ __ - - - - -- _ __ - - - - Jn I _____________________ • - ��p����Q'<�OOG I I 1 EXIT <br />P� �' I'll <br />TOTAL OCCUPANT LOAD = 91 �P�o�O �Q 5�0 r---- - ---- i i I 43 OD <br />X y <br />TRASH d I 1 I 1 <br />1 2446 300 ®� 91 OCCUPANTS/2 EXITS =45/46 OCC. PER IT �� J�Q- \��Ci L____ <br />in9r--- <br />O O w a r\�,`���Q I 66 ------------- ----------� -� <br />I I I ii PET = 51'-4" 1 <br />~ Q E46T- - - - MEN ,- , �� 101 300! \ �``P 1 r---1- 2612 CO -WORKING 5 <br />_� t i P� 1 i I 175 A-3 ----- 1 <br />L----- ---- ------ 1 \ <br />F -1 1 <br />� <br />II <br />' UI <br />I I <br />wl I , I <br />1 i a MP <br />OE , L_________J <br />86 300 <br />nt II 1 1 R-2 <br />I I CPET = 52'-0" <br />�- L L L=83'-8" <br />0 <br />i <br />LU <br />r <br />� � 1 <br />i� /1 <br />J <br />DWELLING UNIT <br />1003 200 <br />6 <br />R-2 <br />KITCHEN <br />1437 1 200 <br />EXIT 8 M <br />45 <br />-- (__- rrn���77Trrrn-n� <br />IIIIIIIIIIIIIIIIII <br />IIIIIIIIIIIIIIIIII <br />IIIIIIIIIIIIIIIIII <br />/ IIIIIIIIIIIIIIIIII <br />EXIT <br />�(0 0 86 <br />h^ <br />?� O� <br />EGRESS OPENING WIDTH i i ��v �T< 0 <br />TOTAL OCCUPANTS 45 <br />EGRESS WIDTH PER OCCUP 0.2 �� O TyFFX/T 3 OV GOiyq� 1 ❑ <br />REQUIRED OPENING WIDTH 9" \` EX ^\� OVER ��<<e�s <br />PROPOSED DOOR WIDTHPROPOSED OPENINGWIDTH M13.633.4" 6 O/M�c�sOgR TS'/ �\2243j2 <br />, )J? , �, SFc 7T�FS <br />t� <br />EGRESS OPENING WIDTH <br />TOTAL OCCUPANTS <br />86 <br />EGRESS WIDTH PER OCCUP <br />0.2 <br />REQUIRED OPENING WIDTH <br />17.2" <br />PROPOSED OPENING WIDTH <br />MIN. 33.4" <br />PROPOSED DOOR WIDTH <br />36" <br />RESTAURANT <br />2573 <br />15 <br />172 <br />A-3 <br />o s <br />7119 <br />_ L _ <br />i ❑ <br />1 <br />L____ <br />1 <br />N <br />I <br />I <br />---------�� <br />I <br />I 1 <br />--- J <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />1 r- ----- <br />-- I 1 1 <br />r--------, r-------- , I I I m 1 II <br />1 1 OFFICE 1 <br />160 150 <br />I I OFFICE r 1 RD <br />1 <br />0 i i 145 150 'I 2 A-3 <br />I I I 1 A-3 <br />TOTAL LEASING/C -WORK G 1 1 <br />I <br />I I I I OCCUPANT LOAD 198 <br />L=122'-0" I 1 <br />198 OCCUPANTS/ EXITS 66 OCC. 11 1 I <br />PER EXIT <br />WORK POD CONFERENCE 1 1 --- <br />78 1 150 1 1 1 <br />1 A-3 Q T 174 A 3 1 - <br />i 1 1 I <br />� 1 1 1 I u (J <br />p <br />_Qom o o i- 1 <br />+-�------------ ^ ti 2 <br />I u <br />i pi <br />0OQ V 0 i 1 L_J I 1 <br />z co /Z. U � <br />L 0) L•. I __J I <br />6�Q0 "'_� i --- - 42 1 <br />z a W � �' 1 WORK POD <br />��UJ 1 1 150 I j <br />1 A-3 1 � 1 <br />army � I _ 1 <br />�,oQ� O 1 1 Ij 112 <br />M Co � I r-------- <br />DWELLING UNIT <br />1256 <br />200 <br />7 <br />R-2 <br />EGRESS OPENING WIDTH <br />TOTAL OCCUPANTS <br />112 <br />EGRESS WIDTH PER OCCUP <br />0.2 <br />REQUIRED OPENING WIDTH <br />22.4" <br />PROPOSED OPENING WIDTH <br />MIN. 33.4" <br />PROPOSED DOOR WIDTH <br />36" <br />`L O 181'-1 233/256 " <br />r---- <br />-�ti <br />- -- <br />i OORK POOD <br />3J?�`dH�SIa <br />fit? <br />'C 1/3 OVERALL DIMENSION=106'-O" <br />I <br />i 1 <br />k O <br />I I ; <br />112 FR <br />p <br />I i <br />P <br />I I I <br />I <br />co <br />1 1 <br />1 <br />j <br />RETAIL <br />I J <br />---- I--J� <br />L____ <br />___- <br />1 1 <br />1------ <br />I <br />8103 60 <br />1 <br />1 <br />135 M <br />1 <br />1 <br />1 <br />I <br />I <br />I <br />-1 <br />I <br />I <br />I <br />I <br />I 41 <br />1 <br />1 <br />J <br />I <br />I <br />I <br />r i <br />i �� FITNESS <br />51'-6" <br />i <br />1553 50 <br />qEXIT <br />1/3 OVERALL DIMENSION=41'-8" EXIT <br />P <br />32 A-3 <br />1 __ 67 <br />-- -- - <br />_ 68__ <br />- - - - - - - - - - - ---------- - -- -- -- <br />qu <br />�i <br />I <br />I <br />, <br />I <br />EXIT I <br />I <br />L _J <br />[�v� / ^ <br />I I �`Ja V HJSIQ <br />L----------- J <br />[�v� /� ^ <br />1 1 I 119J ] V HJSIQ <br />L-----------J L-----------J J <br />L---------- J <br />I - <br />1 I <br />66 I <br />j CPET = 62'-1" <br />I <br />lIX3 <br />lIX3 <br />3J2]b'HOSIa <br />lIX3 <br />EGRESS OPENING WIDTH <br />TOTAL OCCUPANTS <br />68 <br />EGRESS WIDTH PER OCCUP <br />0.2 <br />REQUIRED OPENING WIDTH <br />13.6" <br />PROPOSED OPENING WIDTH <br />MIN. 33.4" <br />PROPOSED DOOR WIDTH <br />36" <br />EGRESS OPENING WIDTH <br />TOTAL OCCUPANTS <br />47 <br />EGRESS WIDTH PER OCCUP <br />0.2 <br />REQUIRED OPENING WIDTH <br />8.4" <br />PROPOSED OPENING WIDTH <br />MIN. 33.4" <br />PROPOSED DOOR WIDTH <br />36" <br />STAIR WIDTH <br />TOTAL OCCUPANTS <br />42 <br />EGRESS WIDTH PER OCCUP <br />0.3 <br />REQUIRED STAIR WIDTH <br />12.6" <br />PROPOSED STAIR WIDTH <br />48" <br />OCCUPANT LOAD SCHEDULE <br />Name Area Occ. Load Factor Occ. Load <br />REQUIRED STAIR WIDTH (CBC 1005.3.1) <br />OCCUPANT LOAD X 0.3" = (REQ'D STAIR WIDTH) <br />REQUIRED DOOR AND OTHER EGRESS COMPONENTS WIDTH (CBC 1005.3.2 <br />OCCUPANT LOAD X 0.2" = REQ'D WIDTH OF EGRESS COMPONENTS <br />AREAS CALCULATED <br />S-2 EXITING REQUIREMENTS: <br />BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT <br />TRAVEL DISTANCE PER CBC TABLE 1017.2 400 FEET W/ FIRE <br />SPRINKLERS PER CBC 903.3.1.1 <br />R-2 EXITING REQUIREMENTS: <br />BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT <br />TRAVEL DISTANCE PER CBC TABLE 1017.2 250 FEET W/ FIRE <br />SPRINKLERS PER CBC 903.3.1.1 OR 903.3.1.2 <br />DISTANCE BETWEEN EXITS SHALL COMPLY WITH CBC 1007.1.1 <br />ACCESSIBLE MEANS OF EGRESS <br />1. THE ACCESSIBLE MEANS OF EGRESS SYSTEM CONSISTS OF THE FOLLOWING: <br />A. ACCESSIBLE ROUTE -SAME AS PATH OF EGRESS (INDICATED IN LEGEND AND SHOWN BY SYMBOL) <br />B1. ELEVATOR REQUIRED PER CBC 1009.2.1 ONE ELEVATOR IS REQUIRED ACCESSIBLE MEANS OF EGRESS AND IS <br />COMPLYING WITH SECTION 1009.4. <br />OR <br />B2. ELEVATOR NOT REQUIRED PER CBC 1009.2.1 AND EXCEPTION #1, ELEVATOR IS NOT REQUIRED AS AN ACCESSIBLE <br />MEANS OF EGRESS. <br />C. INTERIOR STAIRWAYS: INTERIOR STAIRWAYS COMPLY WITH CBC 1009.3 EXCEPTIONS #2 AND #5. <br />EXIT PLAN NOTES <br />1. REFER TO FIRE PROTECTION NOTES. <br />1.1. PROVIDE AUTOMATIC FIRE SPRINKLER SYSTEM <br />1.2. PROVIDE FIRE ALARM SYSTEM <br />1.3. PROVIDE STANDPIPES <br />2. PROVIDE MEANS OF EGRESS IDENTIFICATION PER CBC SECTION 1013: <br />2.1. EXIT SIGNS (EXCEPT TACTILE SIGNS) SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. <br />2.2. TACTILE EXIT SIGNS SHALL BE PROVIDED AT THE FOLLOWING LOCATION (REFER TO SEGMENT FLOOR PLANS <br />FOR SPECIFIC LOCATIONS): <br />A) EACH GRADE LEVEL EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1013.4. <br />B) EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1011.1, AND LEAD DIRECTLY TO A GRADE LEVEL <br />EXTERIOR EXIT BY MEANS OF STAIRWAY OR RAMP SHALL BE IDENTIFIED AS: <br />i) "EXIT STAIR DOWN" <br />ii) "EXIT RAMP DOWN" <br />iii) "EXIT STAIR UP" <br />iv) "EXIT RAMP UP" <br />2.3 INTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.5. <br />2.4 EXTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.6. <br />A) EXIT SIGN GRAPHICS SHALL COMPLY WITH CBC SECTION 1013.6.1. <br />B) THE FACE OF EXIT SIGN SHALL BE ILLUMINATED WITH AN INTENSITY OF NO LESS THAN 5 FOOTCANDLES (45 <br />LUX). <br />C) EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. <br />D) PROVIDE BACKUP POWER IN CASE OF PRIMARY POWER LOSS IN CONFORMANCE WITH CBC SECTION 1013.6.3. <br />2.5 ADDITIONAL EXIT SIGNS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT CHANGE DURING FINAL <br />INSPECTION. <br />3. PROVIDE FIRE EXTINGUISHERS: <br />3.1. PROVIDE A MINIMUM OF ONE 2 A:10 B:C (2A:206C WITHIN 50' 0" AT GARAGE) CLASSIFICATION FIRE <br />EXTINGUISHER WITHIN 75 FEET TRAVEL DISTANCE FOR EACH 6,000 SQUARE FEET OR PORTION THEREOF ON <br />EACH FLOOR. <br />3.2. ADDITIONAL FIRE EXTINGUISHERS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT TO CHANGE DURING <br />FINAL INSPECTION. <br />4. EACH DWELLING UNIT SHALL HAVE PERMANENTLY WIRED SMOKE ALARMS WITH BATTERY BACKUP INSIDE EACH <br />BEDROOM AND CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO SLEEPING AREAS. SMOKE <br />ALARMS SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREA OF THE UNIT. <br />5. INTERIOR FINISHES SHALL COMPLY WITH CBC CHAPTER 8. <br />6. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, WILL BE ILLUMINATED TO A LEVEL NOT LESS ONE FOOT <br />CANDLE AT WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. <br />7. SIGNAGE INDICATING SPECIAL ACCESSIBILITY PROVISIONS SHALL COMPLY WITH CHAPTER 11A, SECTION 1143A. <br />SYMBOL LEGEND <br />■ ■ ■ ■ 3-HR FIRE WALL - SEE AD-26 <br />■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ L = XX' EXIT ACCESS TRAVEL DISTANCE, SEE ALSO TRAVEL <br />DISTANCE SCHEDULE MOST REMOTE POINT TO EXIT <br />ACCESS <br />■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ CPET = XX' COMMON PATH OF EGRESS TRAVEL DISTANCE <br />IHEO HORIZONTAL EXIT <br />XXC5 <br />LU <br />FLOOR AREA <br /># OF OCCUPANTS <br />EXIT AND OCCUPANT LOAD <br />OCCUPANT SPACE/FUNCTION <br />OCCUPANT LOAD SF/OCCUPANT <br />OCCUPANCY TYPE <br />FIRE EXTINGUISHER CABINET MAX. <br />F.E.C. 75'-0" O.C., SEE DETAIL XX <br />XX.XX <br />STANDPIPE <br />INTERIOR EXIT STAIR <br />HORIZONTAL EXIT REFUGE AREA <br />® EXIT SIGN PER CBC SECTION 1013 <br />• <br />Architecture + Planning <br />17911 Von Karman Ave. <br />Suite 200 <br />Irvine, CA 92614 <br />ktgy.com <br />949.851.2133 <br />KTGY Project No: 2017-0934 <br />Project Contact: Debbie Holland <br />Email: dholland@ktgy.com <br />Principal: Wil Wong <br />Project Designer: D. Schoolmeester <br />Project Director: Debbie Holland <br />Developer <br />ED#_0 A K <br />INVES'1•I�'iEN�I'S <br />4199 CAMPUS DRIVE <br />IRVINE, CA 92612 <br />PHONE NO. (714) 342-2502 <br />1 <br />i <br />o. Date Description H <br />10 <br />W <br />v J <br />U <br />W <br />2 <br />U <br />Z <br />Q <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />dr <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />v J <br />ARCy�T <br />LL <br />��SED <br />N <br />N <br />* No. C29795 * <br />C) <br />RENEWAL DATE <br />AUGUST 31, 2023 <br />9jF of <br />r <br />O <br />CA� <br />License Stamp <br />o <br />BUILDING A FIRST <br />FLOOR EXITING <br />ANALYSIS <br />BUILDING A - LEVEL 1 EXITING ANALYSIS SCALE: 3/32"=1'-0} 1 <br />I <br />COPYRIGHT n <br />AO-31 <br />