Laserfiche WebLink
NOTES <br />1. ALL NEW FOOD SERVICE ESTABLISHMENTS SHALL COMPLY <br />WITH CITY ORDINANCE NS-26-70 FOR FAT, OIL AND <br />GREASE (FOG) CONTROL PROGRAM. <br />2. THE BMP'S SHOWN ON THE APPROVED SITE PLAN ARE <br />ONLY PRELIMINARY AND WILL BE REVISED OR MODIFIED <br />AS NECESSARY UPON COMPLETION OF THE WQMP. PRIOR <br />TO THE ISSUANCE OF THE GRADING PERMIT, THE <br />APPROVED GRADING/UTILITY PLAN SHALL INCORPORATE <br />ALL REQUIRED STRUCTURAL BMP'S. <br />3. THIS SITE WILL BE DESIGNED AND CONSTRUCTED IN <br />ACCORDANCE WITH THE CALIFORNIA REGIONAL WATER <br />QUALITY CONTROL BOARD SANTA ANA REGION ORDER NO. <br />RS-2009-0030 DISCHARGE REQUIREMENTS (MS4 PERMIT) <br />4. DEMAND CALCULATIONS FOR SIZE DETERMINATION OF <br />DOMESTIC, IRRIGATION AND FIRE SERVICE WATER METERS <br />TO BE CONFIRMED IN FINAL DESIGN. <br />5. SEPARATE LANDSCAPE IRRIGATION WATER SERVICE/METER <br />SHALL BE USED TO IRRIGATE ALL NON-RESIDENTIAL <br />IRRIGATED LANDSCAPES OF 1,000 SQ. FT. AND <br />RESIDENTIAL IRRIGATED LANDSCAPES OF 5,000 SQ. FT. OR <br />GREATER. LANDSCAPE IRRIGATION WATER METER OF <br />PROPER SIZE SHALL BE DESIGNED TO SUPPLY THE <br />PROJECT'S LANDSCAPE IRRIGATION SYSTEM. IRRIGATION <br />SYSTEM SHALL UTILIZE WEATHER BASED IRRIGATION <br />CONTROLLERS "SMART TIMERS" AND ROTATING NOZZLES <br />FOR POP-UP SPRAY HEADS. <br />6. ABANDONMENT OF ALL SEWER LATERAL CONNECTIONS <br />FROM THE PROJECT SITE SHALL BE REMOVED TO THE <br />SEWER MAIN. <br />7. ALL UTILITY PIPE SIZES TO BE CONFIRMED IN FINAL <br />DESIGN. <br />8. INSTALL DOUBLE CHECK VALVE AND BACK FLOW <br />PREVENTER FOR THE FIRE SERVICE AND THE LANDSCAPE <br />WATER METER PER THE GRADING AND THE STREET <br />IMPROVEMENT PLANS. <br />ABBREVATIONS <br />AD AREA DRAIN LAT LATERAL <br />CB CATCH BASIN MH MANHOLE <br />DCDA DOUBLE CHECK MWS MODULAR WETLAND <br />DETECTOR ASSEMBLY SYSTEM <br />DW DOMESTIC WATER OHW OVERHEAD WIRE <br />EXIST. EXISTING PROP. PROPOSED <br />FW FIRE WATER SD STORM DRAIN <br />HYD FIRE HYDRANT SS SANITARY SEWER <br />IRR IRRIGATION WM WATER METER <br />LEGEND <br />SS <br />— EXISTING SEWER LINE <br />DW <br />— EXISTING DOMESTIC WATER LINE <br />SD <br />— EXISTING STORM DRAIN LINE <br />— G <br />— EXISTING GAS LINE <br />EXISTING OVERHEAD WIRE <br />ss <br />PROPOSED SEWER LINE <br />DW— <br />PROPOSED DOMESTIC WATER LINE <br />PROPOSED FIRE WATER LINE <br />FW <br />- <br />PROPOSED AREA DRAIN LINE <br />- "''1I <br />FUSCOE <br />E N G I N E E R I N G <br />16795 Von Karman, Suite 100 <br />Irvine, California 92606 <br />tel 949.474.1960 0 fax 949.474.5315 <br />www.fuscoe.com <br />Architecture + Planning <br />888.456.5849 <br />ktgy.com <br />WA'l ERFORD <br />— 18"DW ---t18"DW 1 <br />CENTRAL POINTE <br />SANTA ANA, CA # 2019-0129 <br />SCHEMATIC DESIGN <br />July 20, 2020 <br />FOURTH STREET <br />40' 0' 20' 40' <br />SCALE: 1 " = 40' <br />V <br />OW I E. r< ✓ V \­� \_� `3, _ �� L td/ I I \ <br />— — — — — — — <br />{XI ' -- M`TO T. TRAFFIC EOH <br />`E� <br />EXIST DW EXIST. SS MAIN <br />- 1o 2"DW=r 12"DW 12"D, MAIN w (OCSD) �2"DW <br />O <br />000 <br />C <br />EXIST. EXIST. <br />10'SS 10'SS 10'SS 10'SS 10'SS SS MH SS MH <br />EXIST. <br />ST. LIGHT / b <br />EXIST. SS MAIN <br />(OCSD) <br />SITE PLAN - UTILITY <br />C4.0 <br />