My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Item 18 - Appeal Application Nos. 2023-02 and 2023-03 for Cabrillo Town Center project
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2023
>
10/03/2023 Regular
>
Item 18 - Appeal Application Nos. 2023-02 and 2023-03 for Cabrillo Town Center project
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/3/2023 11:38:41 AM
Creation date
10/3/2023 9:16:35 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Item #
18
Date
10/3/2023
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1768
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Chapter 4 Mitigation Monitoring and Reporting Program <br />Table 4-1 <br />Impacts <br />Mitigation Monitoring Program for the Metro East Mixed Use Overlay <br />MitigationMeasures MonitonngParry <br />Zone Component <br />Implementing <br />Parry <br />MitigationTiming <br />or the job superintendent receives a complaint, the superintendent shall <br />investigate, take appropriate corrective action, and report the action taken to <br />the reporting party. <br />■ Contract specifications shall be included in the proposed project construction <br />documents, which shall be reviewed by the City prior to issuance of a grading <br />permit. <br />NM OZ 4.9-3 The project applicant shall require by contract specifications that <br />Planning and <br />Project <br />Prior to Issuance of <br />construction staging areas along with the operation of earthmoving equipment <br />Building Agency <br />Applicant <br />Grading Permit <br />within the project area would be located as far away from vibration and noise <br />sensitive sites as possible. Contract specifications shall be included in the <br />proposed project construction documents, which shall be reviewed by the City <br />prior to issuance of a grading pen -nit <br />NM OZ 4.9-4 The project applicant shall require by contract specifications that <br />Planning and <br />Project <br />Prior to Issuance of <br />heavily loaded trucks used during construction would be routed away from <br />Building Agency <br />Applicant <br />Grading Perarit <br />residential streets to the extent feasible. Contract specifications shall be included <br />in the proposed project construction documents, which shall be reviewed by the <br />Cityprior to issuance ofa grading permit. <br />Impact 4.9-2: Operation of the <br />NM OZ 4.9-5 Where future residential uses would be construction in areas <br />Planning and <br />Project <br />Prior to Issuance of <br />proposed project could expose <br />exposed to noise levels greater than 60 dBACNEL, prior to issuance of building <br />Building Agency <br />Applicant <br />Building Permits <br />noise -sensitive land uses to noise <br />permits, building plans shall reflect the construction ofnoise barriers around patios <br />levels that exceed the standards <br />and balconies. The barriers shall be constructed ofmaterials that provide a surface <br />established by the City of Santa <br />density of at least four pounds per square foot and shall be continuous, without <br />Ana General Plan. <br />gaps or gates. The height of the barriers shall be sufficient to reduce the exterior <br />noise levels to a CNELof 65 dBAor less, and shall be determined by a qualified <br />acousticalconsultant as part ofthe final engineering design ofthe project. <br />MMOZ 4.9-6 Prior to issuance of building pemuts, building plans shall specify the <br />Planning and <br />Project <br />Prior to Issuance of <br />STC rating of windows and doors for all residential land uses. Window and door <br />Building Agency <br />Applicant <br />Building Permits <br />ratings shall be sufficient to reduce the interior noise level to a CNELof45 dBAor <br />less, and shall be determined by a qualified acoustical consultant as part of the <br />final engineering design ofthe project. <br />NM OZ 4.9-7 The developer shall provide proper shielding for all new HVAC <br />Planning and <br />Project <br />During Project <br />systems used by the proposed residential and mixed use buildings to achieve an <br />Building Agency <br />Applicant <br />Design and <br />attenuation of 15 dBAat 50 feet from the equipment. <br />Construction <br />Metro East Mivarl I Ica Ovprla�i 7nnp (\/nIi imp 111) 4-15 <br />City Council 18 — 414 10/3/2023 <br />
The URL can be used to link to this page
Your browser does not support the video tag.