Laserfiche WebLink
Inspector, sim 1] be considered as new work and constructed in con. <br />formity with the requirements of this ordinance, and no person or <br />persons shall connect or cause to be connected shy plumbing or <br />house drainage work with ~ny cesspool or public sewer unless the <br />said plumbing and house draining work conform to the requirements <br />of this ordinance. <br /> <br /> SECTION 92 - PERSONS LIABLE: When anything is prohibi- <br />ted in this ordinance, not only the person actually doing the pro <br />hibtted t~ing but also the employee ~ud all other persons active- <br />lyconcerned therein shall be liable upon conviction to the penalt <br />prescribed~ <br /> <br /> SECTION 98 - GAS FITTING: The following regulations <br />shall ~overn all gas fltt~ng for buildings within the City of Sar <br />ta Ana: <br /> <br /> The following schedule of maximum lengths and number of <br />burners ~ermitted in conuectlon with various sizes of pipe is <br />hereby established, and all installation of gas pipe shall be in <br />accordance herewith: <br /> <br /> TABLE SHONING LENGTH AND MINIMUM SIZE OF GAS PIPE WHICH MUST <br /> <br />BE RUN, <br /> <br /> SIZE GREATEST LENGTH GREATEST NO OF BURNERS. <br /> 3/8" * 15' 2 <br /> 1/2" 25' 6 <br /> <br /> 3/4" 50' 15 ' <br /> 1" V5t 30 <br /> 1 1/4" 100~ 60 <br /> 1 1/2" 150' 100 <br /> 2" 200' 200 <br /> <br />t~ble: <br /> <br /> *Vertical only. <br /> <br />In estimating the number of lights, use the following <br /> <br /> 1 burner for each side light or hall drop. <br /> 3 burners for each heating stove or drop light. <br /> 6 burners for each gas water heater. <br /> l0 burners for each kitchen range. <br /> <br /> The number of lights allowed per 3/8" opening is two <br /> (2), using the ordinary gas bur~er. No 3/8" pipe shall be run <br /> horizontally. No gas pipe of less than 3/8" shall be used in <br /> piping buildings. Openings intended for meter connections must <br /> be conveniently located and under the direction of the Plumbing <br /> Inspector. <br /> <br /> The size of drops shall be at least one half (1/2) inck <br /> Drops shall not extend through the plaster more than 3/4 of one <br /> inch. Bracket outlets shall not extend through the plaster more <br /> than three-fourths (3/4) of an inch. All gas outlets shall be <br /> closed by iron caps. <br /> <br /> For hotels, theatres, churches or public buildings, <br />where a large smount of gas is to he used, the pipes must be of <br />increased size, and plans of the ssme must be submitted to the <br /> <br /> <br />