CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: 25-6030 <br />TRAFFIC SIGNAL INSTALLATION AT SEGERSTROM AVENUE AND ROSEWOOD <br />AVENUE <br />4.09 ADVANCED TRAFFIC CONTROLLER CABINET (ATCC) <br />If called for in the plans, the cabinet shall meet the following: <br />1. The ATCC shall meet the ATC 5301 V02.02 Advanced Transportation Controller <br />Cabinet Standard 2019. ATCC shall be the High Voltage version meeting <br />traditional 120 VAC service voltage to control 120 VAC low power signal heads. <br />2. The cabinet housing shall be a ATCC 352 enclosure with a dimension of 66 in. High <br />x 24 in. Wide x 30 in. Deep. The color shall be an Aluminum finish, Federal <br />Standard 595C, # 17178. The cabinet lock shall be industry standard #2 locks. <br />3. In addition, cabinet and service cabinet meter shall be vinyl wrapped prior to <br />installing in the public right-of-way as follows: <br />a. Vinyl graphics theme and layout shall be reviewed and approved by Engineer <br />prior to printing and installing vinyl on cabinet and service cabinet meter. <br />b. Vinyl wrap graphics shall be printed on 3-M vinyl with Clean Slate Group graffiti <br />resistant laminate, manufactured by Econolite or approved equivalent. <br />c. Vinyl wrap shall be installed onto cabinet and service cabinet meter in strict <br />adherence to manufacturer recommendations and shall be free of air bubbles, <br />wrinkles, and/or lifted sections, edges, or corners. <br />1. The Cabinet Assembly shall consist of but not limited to the following: <br />a. Mounting Cage <br />b. Cabinet Ventilation <br />c. Cabinet lighting <br />d. Document Drawer <br />e. Power Distribution Assembly <br />£ Input Assembly (48 Channels) Vehicle Detection <br />g. Field Input Termination Assembly (48 Channels) <br />h. Output Assembly (16 Channels) <br />i. Field Output Termination Assembly (16 Channels) <br />j. Service Assembly <br />k. Police Door Switch Panel <br />1. All other associated wiring, hardware and foundation bolts. <br />2. Sub -Assembly Details <br />a. ATCC Power Assembly <br />i. SB1/SB2 and DC/Clean Power Bus shall include DB25 D-submodular <br />socket connectors to interconnect the S131/SB2 communication ports <br />of the assemblies and Controller. It shall include a termination circuit <br />57 <br />