Laserfiche WebLink
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: 25-6030 <br />TRAFFIC SIGNAL INSTALLATION AT SEGERSTROM AVENUE AND ROSEWOOD <br />AVENUE <br />6.09 VITRIFIED CLAY PIPE (VCP) SEWER MAIN <br />Where indicated on the plans, sanitary sewer pipe shall be extra strength vitrified clay pipe <br />(VCP) with compression joints conforming to Subsection 207-8 of the Standard <br />Specifications. <br />Underground conduit construction shall conform to all applicable Subsections of Section <br />306 of the Standard Specifications, the Standard Plans and these Special Provisions. <br />Potholing shall be considered as part of the excavation necessary for the work. The <br />Engineer shall be given the opportunity to inspect the existing improvement when it is <br />exposed. <br />Any adjustments in line or grade which will be necessary to accomplish the intent of the <br />plans shall be made. In the event obstructions are encountered during the progress of the <br />work which will require alterations to the plans, the Engineer shall have the authority to <br />change the plans and order the necessary deviation from the line or grade. Contractor shall <br />not make any deviation from the specified line or grade without approval by the Engineer. <br />Pipe sections shall not be deflected at any joint, either vertically or horizontally, beyond <br />the limits specified by the manufacturer. <br />The pipe and fittings shall be lowered into the trench. Do not throw the pipe or fittings into <br />the trench. <br />If it is determined that bypassing of sewer flow will be required, the bypass pumping <br />system shall have sufficient capacity to pump the peak flow. Sewer bypassing shall <br />conform to Section 6-21 of these Special Provisions. The Contractor shall provide bypass <br />piping for the effluent during the construction of the sewer main between manholes. The <br />inlet of the downstream manhole and the outlet of the upstream manhole shall be plugged. <br />A portable pump shall be installed in the upstream manhole to discharge the effluent from <br />the upstream manhole to the downstream manhole through the bypass piping. Pump and <br />bypass piping shall be of adequate size and capacity to handle the flow without sewage <br />backup occurring to facilities connected to the sewer. <br />For sewers 12-inches in diameter and larger, or where deemed necessary by the City, the <br />following shall apply: <br />All pumps used shall be fully automatic self -priming units. All pumps used must be <br />constructed to allow dry running for long periods of time to accommodate the cyclical <br />nature of effluent flows. The Contractor shall provide the necessary stop/start controls for <br />each pump. The Contractor shall have adequate standby equipment available and ready <br />for immediate operation and use in the event of an emergency or breakdown. One standby <br />pump for each size pump utilized shall be installed at the mainline flow bypassing <br />locations, ready for use in the event of primary pump failure. The Contractor shall <br />continually monitor all pumping equipment. The Contractor shall perform leakage and <br />92 <br />