My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SIEMENS BUILDING TECH 1 -2003
Clerk
>
Contracts / Agreements
>
S
>
SIEMENS BUILDING TECH 1 -2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/4/2020 11:36:44 AM
Creation date
1/23/2004 10:25:00 AM
Metadata
Fields
Template:
Contracts
Company Name
Siemens Building Technologies, Inc.
Contract #
A-2003-022
Agency
Finance & Management Services
Council Approval Date
2/3/2003
Expiration Date
3/1/2014
Insurance Exp Date
10/1/2008
Destruction Year
2019
Notes
Amended by A-2003-022-01
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
262
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Bus bars: 98% conductivity copper of the capacity indicated, and arranged for <br />operation at voltages and phase scheduled. <br /> <br />Interior arrangement: So arranged that individual circuit breakers can be removed or <br />installed without disturbing adjacent units, bus structures, or insulation. Refer to Panel <br />Schedule for number of branches, main and branch circuit sizes, poles and trip ratings. <br /> <br />Spares and spaces: Space positions complete in all respects, ready for future load <br />wiring. Space positions as indicated shall be completely bussed and ready for the <br />future insertion of the circuit breaker. <br /> <br />2.18 <br /> <br /> A. <br /> <br />Overcurrent elements: <br /> <br />Circuit breakers: Bolted type, quick-make, quick-break temperature compensated <br />thermal magnetic trip, with frame size, poles, trip rating and minimum rms <br />interrupting rating as indicated and scheduled. <br /> <br />Include a separate ground bus bar in all panels. <br /> <br />Identification: Include manufacturer's nameplate and Underwriters Laboratories, Inc., <br />inspection label on interior of cabinet. For branch circuit panel identify each circuit <br />protective device by typewriiten directory of permanent number referenced to circuit <br />location load directory on interior of cabinet door. Equip distribution panelboards with <br />individual white letter, black plastic laminated identification plates for each circuit <br />protective device. <br /> <br />Wiring gutter: Provide all around interior perimeter. Cross section dimension of gutter <br />as required by code but not less than 16 square inches, or as required to include a total <br />cross section such that indicated circuit conductors and future conductors, based upon <br />spaces indicated, will not exceed in total cross sectional area 30% of the gutter area. <br /> <br />Panelboard height: Do not exceed 78 inches except that floor standing panelboards <br />may be 90 inches high providing top operating handle is within 6 feet of floor. <br /> <br />Bussing arrangement: Refer to schedules for voltage and phase of individual <br />panelboards. Equip line and neutral bus with lugs to accept feeders indicated. Connect <br />circuit protective devices to main bussing arranged for sequenced phasing. <br /> <br />POWER DISCONNECT SWITCHES <br /> <br />Provide power disconnect switches having product construction requirements as <br />specified and/or indicated. Where not otherwise indicated, the following requirements <br />apply: <br /> <br />BASIC MATERIALS AND METHODS 16050-13 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.