CITY OF SANTA ANA <br /> F. Brace and Carriage Bolt Specification <br /> 1f2'COX PLYWOOD <br /> WS'USS STANDARD <br /> FLAT WASHER Irr USS STANDARD <br /> FLAT WASHER <br /> BRAG BRACE <br /> iI <br /> •i <br /> ' ROUNDED HEAD OF 3r9" <br /> CARRLkGE BOLT <br /> ON WEATHER SIDE OF <br /> OPENING <br /> CONSTRUCTION <br /> GRADE NUT <br /> COURSETHREAD <br /> 3W HOLE IN BRACE AND <br /> PLYWOOD-- PRE-DRILLED <br /> DURING FABRICATION <br /> 3I8`)C 12"CARRIAGE BOLT <br /> COURSE THREAD <br /> ROUNDED HEAD <br /> NOTES: <br /> 1) USE 2" BY 4" BY 8' (OR LONGER) CONSTRUCTION GRADE LUMBER FOR BRACES. <br /> 2) USE 3/8" X 12" CARRIAGE BOLTS - ROUNDED HEAD ON OUTSIDE OF BUILDING <br /> 3) TIGHTEN NUTS FROM INSIDE ENOUGH TO SLIGHTLY COMPRESS WASHER INTO 2X4 <br /> BRACE. <br /> 4) USE 1/2" WASHER ON WEATHER SIDE TO ACCOMMODATE THE WRENCH NECK OF <br /> BOLT AND ELIMINATE PRY POINTS. <br /> G. Window Assembly <br /> MATERIALS REQUIRED PER WINDOW <br /> • 1 - 1/2" CDX PLYWOOD SHEET-CUT TO DIMENSIONS OF WINDOW FRAME (WEATHER SIDE) <br /> 4 -2X4 BRACES- CUT TO WIDTH OF PLYWOOD <br /> 4 -CARRIAGE BOLT ASSEMBLIES <br /> NUMBER OF WINDOWS TO BE SECURED (Nw): <br /> NUMBER OF WINDOWS BRACES REQUIRED: (Nw X 4) <br /> CARRIAGE BOLT ASSEMBLIES REQUIRED (Bw): (Nw X 4) <br />