Laserfiche WebLink
3. The finish (paint) shall withstand minimum 1000 hours salt spray resistance testing per ASTM 6117 <br />(extruded aluminum may be anodized instead of painted). <br />C. LED Package (Light Source) Requirements <br />1. The LEDs shall be from Cree, Philips Lumileds, Nichia, Osram or equivalent. <br />2. The LED package shall have been tested for a minimum of 6000 hours per IES LM- 80 -08. <br />3. The LEDs shall be available with a nominal correlated color temperature (CCT) between 2700K - <br />4000K. <br />4. The LEDs shall have a minimum color rendering index (CRI) of 70. <br />5. The projected L70 lifetime (the point in time at which the LEDs are expected to produce only 70% of <br />their initial lumen output) for the Retrofit shall be a minimum of 70,000 hours. Manufacturer shall <br />supply a calculation pursuant to the Department of Energy TM -21 calculations. Please follow this link <br />to the DOE TM -21 calculator — www eneraystar oov1TM -2l calculator. <br />D. Photometric Requirements <br />1. The Retrofit shall deliver gross 90 lumens per watt (LPW) minimum at 350 mA drive current. <br />2. The Retrofit shall have been photometrically tested in a DLC approved fixture per IES LM -79 -08 by and <br />independent laboratory, or an in -house laboratory with NIST NVLAP accreditation. <br />3. Photometric Specification: <br />a. The Retrofit light engine shall have a minimum total luminous output of 4,700 lumens and a total <br />wattage draw of no more than 75 watts for the 150 W replacement and have a minimum total <br />luminous output of 2500 lumens and a total wattage draw of no more than 35 watts for the 70 W <br />replacement, <br />b. The manufacturer shall provide documentation via a photometric layout that their Retrofit as <br />installed in the decorative luminaire meets the photometric performance requirements for sidewalk <br />lighting as follows: <br />i. Parameters: 80 -ft. pole spacing, single row, 14 -ft. mounting height, 10 -ft. wide sidewalk, 3 -ft. <br />setback. Retrofit light loss factor (LLF) no higher than 0.85. <br />ii. Requirements: The Retrofit shall have a Type V distribution, and shall provide pedestrian <br />walkway lighting consistent with 0.50 fc minimum average horizontal luminance, and an <br />avg /min uniformity ratio of 4.0 or less, per IES RP -08 walkway lighting recommendations. <br />E. Electrical Requirements <br />1. The driver (power supply) shall have the following characteristics: <br />a. UL recognized component listed for outdoor use <br />b. Minimum power factor 0.90 <br />c. Maximum THD (Total Harmonic Distortion) 20% <br />d. Compliance with FCC Title 47, Part 15 (Class A) <br />2. The driver shall be available with input voltage ranges from 120 -277 volts. <br />3. The driver, as operated in the luminaire, must not exceed the driver manufacturer's maximum case <br />temperature limits for a rated life of at least 50,000 hours. <br />4. The Retrofit shall be protected against surges according to IEEE C62.42 C High (10 kA and W). <br />RFP FOR LED POST TOP RETROFIT STREETLIGHTS & SARTC STRUCTURE LIGHTING Page 125 <br />