Laserfiche WebLink
Bowers Museum Access Compliance Survey Report <br />Facility: Bowers Museum Part: Interior Floor: Ground Floor <br />Address: 2002 N Main St, Santa Ana, CA 92706 <br />Existing Architectural Barrier <br />Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit <br />Carnetit)oorinat <br />236 • As -Sviit Description: <br />PCODE ID03 4 JOB <br />Doormat not securely attached to around or boor <br />PCODE rD05A <br />structure. <br />ADAAG 4.53 <br />• Proposed Solution: <br />ADA 2010 302.2 <br />Attach doormat to floor surface or remove doormat. <br />CBC 2010 1124B.3 <br />12gor Closer <br />237 • As -Built Description PCODE 1D03 <br />Excessive force required to open door. <br />ADAAG 4.13.11 <br />• As -Built: 17 lbs ADA 2010 404.2.9 <br />• Proposed Solution: <br />Adjust regular door closer to accessible standards (5 CBC 2010 11338.2.5 <br />lbs max). CBC 2013 I113- 404.2.9 <br />1 JOB <br />+®" <br />291 • As -Suitt Description: <br />PCODE ID03 4 JOB <br />Excessive force required to open door. <br />ADAAG 4.13.11 <br />• As- Buick: 10 lbs <br />ADA 2010 404.29 <br />• Proposed Solution: <br />if <br />Adjust regular door closer to accessible standards <br />(5 CBC 2010 113311.2.5 <br />lbs max). <br />CBC 2013 11B- 404.2.9 <br />Protrusion Limits <br />238 • As -BUlif Description: 1 JOB <br />Protruding objects more than 4" from wall, when PCODE EG04 <br />bottom of object more than 27" or less than 80" ADAAG 4.4.1 <br />qa. <br />above finished floor. ADA 2010 307.2; <br />Data - Page 46 <br />