My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
25C - AGMT - OCWD CENTENNIAL PARK
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2016
>
06/21/2016
>
25C - AGMT - OCWD CENTENNIAL PARK
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2016 9:59:52 AM
Creation date
6/16/2016 3:53:42 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Parks, Recreation, & Community Services
Item #
25C
Date
6/21/2016
Destruction Year
2021
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
406
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Section 5 <br />Table 82: Vibration Source Levels for Construction Equipment <br />Location <br />Distance to Nearest <br />Vibration Levels at Nearest Receptor in <br />Sensitive Receptor (feet) <br />Peak Particle'Veloeftyl <br />(Inctnes1socond► <br />MBI-2 <br />450 <br />6.1704 <br />MBI-3 <br />210 <br />6.009 <br />MBi-4 <br />190 <br />0,010 <br />M131-5 <br />220 <br />0.008 <br />Monitoring Well <br />120 <br />0.016 <br />Caltrans Threshold for Transient Vibration Sources <br />0.25 <br />Table 82 shows that the greatest level of vibration impacts would occur at <br />sensitive receptors located near the Monitoring Well at the Heritage Museum with <br />a vibration level of 0.01'6 inch per second PPV. This vibration level would be well <br />within Caltrans 0.250 inch per second PPV threshold of perception for transient <br />sources. Therefore, a less than significant vibration impact would occur from <br />construction and operation of the Proposed Project. <br />Alternative 3: Reduced Intensity Alternative <br />Potential vibration impacts would be similar to the Proposed Project and would <br />be less than significant. <br />Alternative 4: IN peline Design Alternative <br />Potential vibration impacts would be similar to the Proposed Project and would <br />be less than significant. <br />Mitigation Measures <br />No Mitigation measures required <br />Level of Impact <br />Alternative 1: No adverse impact <br />Alternative 2: Less than significant adverse impact <br />Alternative 3: Less than significant adverse impact <br />Alternative 4: Less than significant adverse impact <br />Mid Basin Centennial Park �tc&njl <br />_ *Project Final EIR 5-216 <br />
The URL can be used to link to this page
Your browser does not support the video tag.