Laserfiche WebLink
2808.2 Storage site. Storage sites shall be level and on solid ground or other all - <br />weather surface. Sites shall be thoroughly cleaned and approval from the fire code <br />official obtained before transferring products to the site, <br />(c) Section 2808.3 Size of piles is hereby amended as follows: <br />2808.3 Size of piles. Piles shall not exceed 15 feet (4572 mm) in height, 50 feet (15 <br />240 mm) in width and 100 feet (30 480 mm) in length. <br />Exception: The fire code official is authorized to allow the pile size to be increased <br />where a fire protection plan is provided for approval that includes, but is not limited <br />to the following: <br />1. Storage yard areas and materials - handling equipment selection design and <br />arrangement shall be based upon sound fire prevention and protection <br />principles. <br />2. Factor that lead to spontaneous heating shall be identified in the plan and <br />control of the various factors shall be identified and implemented including <br />provisions for monitoring the internal condition of the pile, <br />3. The plan shall include means for early fire detection and reporting to the public <br />fire department; and facilities needed by the fire department for fire <br />extinguishment including a water supply and fire hydrants. <br />4. Fire apparatus access roads around the piles and access roads to the top of the <br />des shall be established identified and maintained. <br />5. Regular yard inspections by trained personnel shall be included as part of an <br />effective fire prevention maintenance program. <br />Additional fire protection called for in the plan shall be provided and shall be <br />installed in accordance with this code. The increase of the pile size shall be based <br />upon the capabilities of the installed fire protection system and features. <br />(d) Section 2808.7 Pile fire protection is hereby amended by adding the following <br />statement to the last sentence: <br />2808.7 Pile fire protection. Automatic sprinkler protection shall be provided in <br />conveyor tunnels and combustible enclosures that pass under a pile. Combustible <br />conveyor systems and enclosed conveyor systems shall be equipped with an <br />approved automatic sprinkler system. Oscillating sprinklers with a sufficient <br />projectile reach are required to maintain a 40% to 60% moisture content and wet <br />down burning /smoldering areas. <br />(e) Section 2808.9 Material - handling equipment, is hereby amended by adding the <br />following sentence at the beginning of the section: <br />Ordinance No. NS -XXXX <br />Page 37 of 51 <br />75A -61 <br />