My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
75A - PH - BUILDING FIRE CODES
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2016
>
11/15/2016
>
75A - PH - BUILDING FIRE CODES
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2016 5:24:13 PM
Creation date
11/10/2016 5:11:19 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Planning & Building
Item #
75A
Date
11/15/2016
Destruction Year
2021
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
: <br />OEMu <br />SECTION 32: Section 14 -41 is hereby amended to read as follows: <br />Sec. 14 -41. - Referenced standards (Chapter 80). <br />(a) NFPA 13, 24U 2016 Edition, Standard for the Installation of Sprinkler Systems <br />is hereby amended as follows: <br />(1) Section 6.8. 7.3 is hereby amended as follows: <br />6.8 7.3 Fire department connections (FDC) shall be of an approved type. The <br />FDC shall contain a minimum of two 2'/2" inlets. The location shall be approved <br />and be no more than 150 feet from a public hydrant. The FDC may be located <br />within 150 feet of a private fire hydrant when approved by the fire code official. <br />The size of piping and the number of inlets shall be approved by the fire code <br />official. If acceptable to the water authority, it may be installed on the backflow <br />assembly. Fire department inlet connections shall be painted OSHA safety red, <br />When the fire sprinkler density design requires 500 gpm (including inside hose <br />stream demand) or greater, or a standpipe system is included, four 2 '' /2" inlets <br />shall be provided. <br />(2) Section 8.3.3.1 is hereby amended as follows: <br />8.3.3.1. When fire sprinkler systems are installed in shell buildings of <br />undetermined use (Spec Buildings) other than warehouses (S occupancies), <br />fire sprinklers of the quick - response type shall be used. Use is considered <br />undetermined if a specific tenant/occupant is not identified at the time the fire <br />sprinkler plan is submitted. Sprinklers in light hazard occupancies shall be one <br />of the following: <br />MrA <br />Ordinance No. NS -XXXX <br />Page 43 of 51 <br />75A -67 <br />
The URL can be used to link to this page
Your browser does not support the video tag.