My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ENTERPRISE AUTOMATION (2)-2018
Clerk
>
Contracts / Agreements
>
E
>
ENTERPRISE AUTOMATION (2)-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2019 6:18:25 PM
Creation date
3/12/2018 11:07:46 AM
Metadata
Fields
Template:
Contracts
Company Name
ENTERPRISE AUTOMATION
Contract #
A-2018-024
Agency
PUBLIC WORKS
Council Approval Date
2/6/2018
Expiration Date
5/5/2021
Insurance Exp Date
11/13/2019
Destruction Year
2026
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
62
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ENTERPRISE <br />AUTOMATION <br />Enterprise Automation <br />210 Goddard Irvine CA 92618 USA <br />Tel 949-769.6000 Fax 949-769-6005 <br />www.ealntegrator.com <br />6. For EA to gauge the PLC programmer's comprehension of the specification <br />7. For EA to gauge the competency of the PLC programmer <br />IMs additional effort is no included in Fee P.mposa.0 <br />Key Deliverables <br />Client requested: <br />a) Functional Specifications for each site <br />■ Instrument database <br />I/O and communications database <br />Additional scrape (value adds . <br />a) Technical Memorandum for each site (included in the fee proposal) <br />b) Technical Memorandum review workshop for each site (included in <br />the fee proposal) <br />7.6 Programming and testing specifications <br />Leveraging the templates and significant portions of the documents developed for <br />the East Station, SA°5, San Lorenzo, and Walnut Pump Station projects, EA will <br />develop several types of test documentation for each site: <br />1. Control Panel FAT documentation, for use by: <br />a. The PLC programmer for internal panel testing prior to a formal <br />witnessed FAT <br />b. EA to conduct a formal witnessed panel FAT at the PLC <br />programmer's facility <br />2. Control System FAT documentation, for use by: <br />a. The PLC programmer for internal testing of PLC, OIT, and ancillary <br />equipment, prior to a formal witnessed control system FAT <br />b. EA to conduct a formal witnessed control system FAT at the PLC <br />programmer's facility <br />3. Control System SAT documentation, for use by: <br />a. By the PLC programmer, Enterprise automation, and the City <br />during site commissioning <br />b. By the PLC programmer, Enterprise automation, and the City <br />during formal site acceptance testing <br />The test documentation will cover PLC/SCADA related controls only. Any process <br />testing requirements, such as pump capacities, system pressures, eta, must be <br />provided by the City. <br />ClicnC City of Santa Ana Revision, 1.0.0 <br />Document Response to RF P 17-1'12 Date_ 1112 V2017 <br />Section: Scope Seniices & Schedule Page Number 19 of 31 <br />
The URL can be used to link to this page
Your browser does not support the video tag.