Laserfiche WebLink
Project Name: <br />Location (Legal Description of the Project Property): <br />Owner: <br />Landscape Architect: <br />Landscape Contractor: <br />Signed: Title: <br />Date of Signature: <br />Address: <br />PART2-PRODUCTS <br />2.0 SLEEVES AND CONDUIT: <br />Telephone number () <br />A. All sleeves for pressure supply line and non- pressure supply line shall be twice the nominal size of the <br />pipe within. <br />B. Sleeves and Conduit material: <br />1. PVC SCH 40 for 1 "-2 112" pressure supply line. <br />2. PVC SCH40 for 3" and larger pressure supply line. <br />3. PVC SCH 40 for non- pressure lines. <br />4. One 2" PVC SCH 40 for wire conduit for up to 20 wires. <br />5. One 4" PVC SCH 40 wire conduit for 21 to 40 wires. <br />6. One 3/4" PVC SCH 40-wire conduit for flow sensing cable. <br />7. One 3/4" PVC SCH 40-wire conduit for master valve wire. <br />a) Flow sensing cable and master valve wires shall be installed in their own conduit separate <br />and apart from all other wires. <br />2.1 BRASS PIPE AND FITTINGS: <br />A. Brass pipe shall be regular weight, 85% red brass, ANSI Schedule 40 screwed pipe. <br />B. Fittings: Medium brass, screwed at 125-pound class. <br />2.2 BACK -FLOW PREVENTION DEVICE <br />A. Back -flow Prevention Device: As specified on the drawings. <br />2.3 FLOW SENSORS <br />A. Flow Sensors: As specified on drawings. <br />2.4 FLOW SENSORS CABLE <br />A. PVC jacketed two conductor cables. The conductors shall be 16 AWG 7 strand annealed copper, <br />conforming to ASTM B-3 and B-8 with heat and moisture resistant PVC, covered with a .004 wall of <br />City of Santa Ana RFP 17-127 <br />Page 14 <br />