Laserfiche WebLink
SPACE ALLOWANCES AND REACH RANGES SHALL COMPLY WITH CBC SECTIONS 1138A,11 B-DIVISION 3 & 11 B-DIVISION 4. <br />CONTROLS AND OPERATING MECHANISMS SHALL COMPLY WITH CBC SECTIONS 1138A.4,1142A AND 116-309. <br />RAB BARS, TUB AND SHOWER SEATS SHALL COMPLY WITH CBC SECTIONS 1127A.4. <br />SINGLE -ACCOMMODATION TOILET FACILITIES SHALL COMPLY WITH CBC SECTION 1127A.2.2 AND 11 B-603. <br />LANDINGS AND THRESHOLDS SHALL COMPLY WITH CBC SECTIONS 1010.1.6, 1010.1.7, 1126A.2 AND 11 B-302, 11 B-303 I <br />THIS SHEET IS FOR REFERENCE ONLY AND ILLUSTRATES CODE -REQUIRED MINIMUM STANDARDS FOR COMMON <br />AND PUBLIC USE FACILITIES WITHIN A MULTIFAMILY DEVELOPMENT. SEE PERTINENT SHEETS, DRAWINGS, AND <br />A. WHEELCHAIR PASSAGE AND PASSING WIDTHS THE MINIMUM CLEAR WIDTH FOR WHEELCHAIR PASSAGE IS 361, <br />A. GENERAL. <br />A. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, 33" MINIMUM AND 36" MAXIMUM ABOVE THE FINISH <br />A. THERE SHALL BE SUFFICIENT SPACE IN THE TOILET ROOM FOR A WHEELCHAIR MEASURING 30" WIDE BY 48" <br />SPECIFICATIONS FOR APPLICATION OF THESE STANDARDS TO THIS SPECIFIC PROJECT. <br />CONTINUOUSLY. A 32" WIDTH IS ACCEPTABLE AT A POINT NOT TO EXCEED 24" IN LENGTH, SEE FIGURE 1. SEE FIGURE 2. <br />CONTROLS AND OPERATING MECHANISMS IN ACCESSIBLE SPACES, ALONG ACCESSIBLE ROUTES OR AS PART OF <br />FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE. <br />LONG TO ENTER THE ROOM AND PERMIT THE DOOR TO CLOSE . THERE SHALL BE IN THE ROOM A CLEAR <br />FOR THE MINIMUM WIDTH FOR TWO WHEELCHAIRS TO PASS IS 60". <br />ACCESSIBLE ELEMENTS AND THOSE REQUIRED TO BE ACCESSIBLE BY CBC SECTION 1.9.1 SHALL COMPLY WITH THE <br />EXCEPTION: THE HEIGHT OF THE LOWER GRAB BAR ON THE BACK WALL OF A BATHTUB SHALL COMPLY WITH <br />FLOOR SPACE OF AT LEAST 60" IN DIAMETER, OR A T-SHAPED SPACE COMPLYING WITH DETAIL 22, NOTE B, OF <br />a <br />THE INFORMATION CONTAINED WITHIN THESE SHEETS ARE EXCERPTS FROM THE CALIFORNIA BUILDING CODE <br />36"MIN. <br />FOLLOWING REQUIREMENTS; <br />SECTION 1127A.5.2. <br />THIS SHEET; SEE FIGURES 9.1 AND 9.2 BELOW. NO DOOR SHALL NOT ENCROACH INTO THIS CLEAR FLOOR <br />� Q <br />(CBC) AND FAIR HOUSING ACT (FHA) DESIGN MANUAL, AND INTENDED TO PROVIDED THE CONTRACTOR THE <br />4"MIN. CLR. <br />B. CLEAR FLOOR SPACE. <br />B. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB BAR SHALL COMPLY WITH THE FOLLOWING: <br />SPACE FOR MORE THAN 12"; SEE FIGURE 9.2 BELOW. <br />w w <br />GENERAL REQUIREMENTS OF ACCESSIBILITY FOR THIS PROJECT. THE GENERAL CONTRACTOR SHALL BE <br />CLEAR 44" MIN. CORRIDOR <br />A CLEAR FLOOR SPACE THAT ALLOWS A FORWARD OR PARALLEL APPROACH BY A PERSON USING A WHEELCHAIR <br />1. GRAB BARS WITH CIRCULAR CROSS SECTION SHALL HAVE AN OUTSIDE DIAMETER OF 14'. <br />B. WHEN A TOILET ROOM OR BATHING ROOM IS FOR INDIVIDUAL USE AND A CLEAR FLOOR SPACE COMPLYING <br />> M <br />" o- <br />KNOWLEDGEABLE OF AND SHALL BUILD TO ALL APPLICABLE ACCESSIBILITY CODE REQUIREMENTS, IF FURTHER <br />< 10 OC CLEAR WIDTH <br />SHALL BE PROVIDED AT CONTROLS AND OPERATING MECHANISMS. <br />2. GRAB BARS WITH NON CIRCULAR CROSS SECTION SHALL HAVE A CROSS SECTION DIMENSION OF 2" MAXIMUM. THE <br />WITH DETAIL 22, NOTE C, OF THIS SHEET, IS PROVIDED WITHIN THE ROOM BEYOND THE ARC OF THE DOOR <br />� <br />INFORMATION OR CLARIFICATION IS REQUIRED, CONSULT THE ARCHITECT OR REFERENCE THE CBC AND FHA <br />LOAD >_ 10 OCC. o <br />- X z LOAD � ,r Q <br />N o > p o <br />C. HEIGHT. <br />CONTROLS AND OPERATING MECHANISMS SHALL BE LOCATED NO HIGHER THAN 48", AND NO LOWER THAN 15", ABOVE <br />FINISHED FLOOR MEASURED TO THE CENTER OF THE GRIP. IF THE REACH IS OVER AN OBSTRUCTION EXAMPLE, <br />PERIMETER DIMENSION OF GRAB BARS WITH NON -CIRCULAR CROSS SECTION SHALL BE 4" MINIMUM AND AND <br />4.8" MAXIMUM. <br />SWING, DOORS SHALL BE PERMITTED TO SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED <br />FOR ANY FIXTURE; SEE FIGURE 9.2 BELOW. <br />C. PROVIDE ONE ACCESSIBLE WATER CLOSET IN COMPLIANCE WITH THE REQUIREMENTS WITHIN THIS DETAIL <br />DESIGN MANUAL PRIOR TO FABRICATION OR INSTALLATION OF THE WORK. <br />COMMON USE FACILITIES SHALL COMPLY WITH CBC CHAPTER 11A AND ANSI A117.1 AS REFERENCED BY THE FAIR <br />+ z <br />(FOR <br />3. L-SHAPED OR U-SHAPED GRAB BARS SHALL BE PERMITTED. <br />o - z � <br />z w <br />z o � Q c� v <br />WASTHER OR DRYER ,CONTROLS AND OPERATING MECHANISMS SHALL BE LOCATED WITHIN THE REACH RANGES <br />SPECIFIED IN SECTION 1138A.3. SEE DETAIL 22 ON THIS SHEET. CONTROLS AND OPERATING MECHANISMS THAT DO <br />C. THE STRUCTURAL STRENGTH OF GRAB BARS, TUB AND SHOWER SEATS, FASTENERS AND MOUNTING DEVISES SHALL <br />AND DETAIL 1 N THI HEET. PR VIDE NE LAVAT RY IN MPLIAN E WITH DETAIL 12 F THI HEET. <br />0 0 SS 0 0 0 CO C 0 SS <br />D. ALL DOORS FIXTURES AND CONTROLS SHALL BE ON AN ACCESSIBLE ROUTE. THE MINIMUM CLEAR WIDTH OF <br />BEVEL / <br />2 <br />HOUSING ACT FHA DESIGN MANUAL. IF COMMON USE FACILITIES ARE MADE AVAILABLE TO THE PUBLIC IF ONLY <br />( ) <br />PERIODICALLY, THEY MUST COMPLY WITH CBC CHAPTER 11 B AND ADAS N ADDITION TO THE REQUIREMENTS LISTED <br />. o - Q p <br />2" MIN. � w . W M � J <br />Q <br />NOT SATISFY THESE SPECIFICATIONS ARE ACCEPTABLE, PROVIDED THAT COMPARABLE MECHANISMS, CONTROLS OR <br />MEET THE FOLLOWING SPECIFICATIONS: <br />1. BENDING STRESS IN A GRAB BAR OR SEAT INDUCED BY THE MAXIMUM BENDING MOMENT FROM THE APPLICATION <br />AN ACCESSIBLE ROUTE SHALL BE 36" EXCEPT AT DOORS. SEE DETAIL 4 OF THIS SHEET. <br />E. THE ACCESSIBLE ROUTE AND TOILET ROOM FLOOR SHALL BE STABLE, FIRM AND SLIP RESISTANT. <br />J 2%MAXIMUM SLOPE �/ <br />g , g w 1 <br />U) AT EXTERIOR LANDING <br />ABOVE DURING PERIODS OF PUBLIC USE. <br />CLEAR v c> L 60"MIN. CLR. o <br />L C� <br />OUTLETS, THAT PERFORM THE SAME FUNCTIONS, ARE PROVIDED WITHIN THE SAME AREA AND ARE ACCESSIBLE. <br />D. OPERATION. <br />OF A 250-POUND POINT LOAD SHALL BE LESS THAN THE ALLOWABLE STRESS FOR THE MATERIAL OF THE GRAB BAR <br />F. GRAB BARS SHALL BE INSTALLED IN COMPLIANCE WITH DETAILS 10 & 13 OF THIS SHEET. <br />_ = <br />= m <br />WHEN PROVIDED, COMMON USE AREAS AND FACILITIES IN COVERED MULTIFAMILY DEVELOPMENTS SHALL BE <br />PASSING <br />X z <br />N Q b (CORRIDOR OVER 2G 60" MIN. CLR. <br />CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT <br />OR SEAT. <br />2. SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THE APPLICATION OF A 250-POUND POINT LOAD SHALL BE <br />G. THE ENTRANCE DOOR SHALL BE PROVIDED WITH A PRIVACY LOCK OR LATCH IN COMPLIANCE WITH DETAIL 4 <br />OF THIS SHEET. <br />ACCESSIBLE TO PERSONS WITH DISABILITIES. COMMON USE FACILITIES INCLUDE, BUT ARE NOT LIMITED TO; <br />LOBBIES, TOILET AND BATHING FACILITIES, LAUNDRY FACILITIES,COMMUNITY ROOMS, CLUBHOUSES, HEALTH AND <br />GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO <br />GREATER THAN 5 POUNDS OF FORCE. <br />LESS THAN THE ALLOWABLE SHEAR STRESS FOR THE MATERIAL OF THE GRAB BAR OR SEAT, AND IF ITS MOUNTING <br />DOOR LANDINGS <br />FITNESS FACILITIES, GAME ROOMS AND PORTIONS OF COMMON USE TENANT STORAGE. ALL ENTRANCES, DOORS, <br />FIGURE 1 WHEELCHAIR PASSAGE FIGURE 2 WHEELCHAIR PASSING <br />E. INSTALLATION HEIGHTS OF ELECTRICAL SWITCHES AND RECEPTACLE OUTLETS. <br />BRACKET OR OTHER SUPPORT IS CONSIDERED TO BE FULLY RESTRAINED, THEN DIRECT OR TORSIONAL SHEAR <br />48" MIN DOORS SHALL 48" MIN <br />A. THE FLOOR OR LANDING ON EACH SIDE OF AN EXIT DOOR SHALL BE LEVEL. <br />FIXTURES AND CONTROLS SHALL BE ON AN ACCESSIBLE ROUTE. <br />1. ELECTRICAL SWITCHES. CONTROLS AND SWITCHES INTENDED FOR USE BY THE OCCUPANT OF THE ROOM OR <br />STRESSES SHALL NOT EXCEED THE ALLOWABLE SHEAR STRESS. <br />ANEUVERIN COMPLY WITH THE ANEUVERIN <br />REQUIREMENTS <br />PUBLIC USE FACILITIES AND AREAS SHALL COMPLY WITH CBC CHAPTER 11 B AND ADAS. WHEN PROVIDED, PUBLIC <br />B. WHEELCHAIR TURNING SPACE SHALL COMPLY WITH ONE OF THE FOLLOWING FIGURES: <br />60" 2" 36" 2" <br />AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPLIANCES OR COOLING, HEATING AND VENTILATING <br />EQUIPMENT SHALL BE LOCATED NO MORE THAN 48" MEASURED FROM THE TOP OF THE OUTLET BOX NOR LESS <br />THAN 15" FROM THE BOTTOM OF THE OUTLET BOX TO THE FINISH FLOOR OF THE WORKING PLATFORM. <br />2. ELECTRICAL RECEPTACLE OUTLETS. ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30 AMPERES <br />3. SHEAR FORCE INDUCED IN A FASTENER OR MOUNTING DEVICE FROM THE APPLICATION OF A 250-POUND POINT <br />LOAD SHALL BE LESS THAN THE ALLOWABLE LATERAL LOAD OF EITHER THE FASTENER OR MOUNTING DEVICE OR <br />THE SUPPORTING STRUCTURE, WHICHEVER IS THE SMALLER LOAD. <br />4. TENSILE FORCE INDUCED BY A FASTENER BY A DIRECT TENSION FORCE OF A 250-POUND POINT LOAD PLUS THE <br />SPACE SPACE <br />OF DETAIL 4 OF <br />THIS SHEET <br />LAV. OR LAV. OR <br />O © <br />DOOR THRESHOLDS <br />A. THRESHOLDS AND CHANGES IN ELEVATION AT DOORS SHALL NOT BE MORE THAN 1/2" LOWER THAN THE TOP <br />OF THE THRESHOLD OF THE DOORWAY. <br />B. THRESHOLDS WITH A CHANGE IN HEIGHT OF NOT MORE THAN 1/4" MAY BE VERTICAL. <br />USE FACILITIES AND AREAS FACILITIES IN COVERED MULTIFAMILY DEVELOPMENTS SHALL BE ACCESSIBLE TO <br />PERSONS WITH DISABILITIES. <br />z <br />-� -'���` ;-------; = <br />OR LESS AND COMMUNICATION SYSTEM RECEPTACLES SHALL BE LOCATED NO MORE THAN 481, MEASURED FROM <br />THE TOP OF THE OUTLET BOX NOR LESS THAN 15" FROM THE BOTTOM OF THE OUTLET BOX TO THE FINISH FLOOR <br />MAXIMUM MOMENT FROM THE APPLICATION OF A 250 POUND POINT LOAD, SHALL BE LESS THAN THE ALLOWABLE <br />I'--` <br />FIXTURE - FIXTURE <br />� _ _ <br />-:_ _ - -- - <br />C. CHANGES IN LEVEL BETWEEN 1/4" AND 1/2" SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1 VERTICAL <br />UNIT TO 2 UNITS HORIZONTAL. CHANGES GREATER THAN 1/2" SHALL BE ACCOMPLISHED BY MEANS OF A RAMP. <br />PUBLIC USE FACILITIES INCLUDE, BUT ARE NOT LIMITED TO; RENTAL OFFICES, SALES OFFICES AND MAINTENANCE <br />FACILITIES. THESE AREAS, BY THEIR NATURE, ARE OPEN TO PEOPLE OTHER THAN RESIDENTS AND THEIR GUESTS. <br />' , ' ' v <br />\ , , N <br />_ ' �_, <br />' co F <br />OR THE WORKING PLATFORM. EXCEPTIONS INCLUDE TO FOLLOWING CONDITIONS: <br />a. RECEPTACLE OUTLETS INSTALLED AS PART OF PERMANENTLY INSTALLED BASEBOARD HEATERS ARE <br />EXEMPT. <br />WITHDRAWAL LOAD BETWEEN THE FASTENER AND THE SUPPORTING STRUCTURE. <br />5. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. <br />C. A GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT TO IT SHALL BE FREE OF ANY SHARP OR ABRASIVE <br />w 1 I �Q w / 12 <br />p cD c) 4 & o CD U I� �� <br />o Z Q 1 z W o z 0- 4Q- I z W <br />0 � � �`� 1 0 � � 1 <br />w / Q w Q <br />z > 1 I _ J z > 1 ; J <br />DOOR MATS <br />A. IF A DOORMAT IS USED IN A COMMON USE AREA OR PUBLIC USE AREA, IT SHALL HAVE A FIRM BACKING OR NO <br />THEY, THEREFORE, MUST COMPLY. <br />_ <br />% , , M 36"MIN. 8 IN 36"MIN. <br />b. REQUIRED RECEPTACLE OUTLETS SHALL BE PERMITTED IN FLOORS WHEN ADJACENT TO SLIDING PANELS OR <br />ELEMENTS AND SHALL HAVE ROUNDED EDGES. <br />\P� \P� <br />� w , 1 \ 0 1 ' ED o w U 1 o �/ � � u <br />1 1 1 1 <br />BACKING. <br />'� -- ' L------------J <br />L 60� L z � <br />z � � <br />WALLS. <br />c. BASEBOARD ELECTRICAL OUTLETS USED IN RELOCATABLE PARTITIONS, WINDOW WALLS OR OTHER <br />ELECTRICAL CONVENIENCE FLOOR OUTLETS ARE NOT SUBJECT TO THE MINIMUM HEIGHT REQUIREMENTS. <br />D. ADJACENT ELEMENTS, FOR EXAMPLE WATER CLOSET FLUSH VALVES, SHALL BE POSITIONED TO PROVIDE <br />UNOBSTRUCTED USE OF THE GRAB BARS AT THE SPECIFIED LOCATIONS. THE SPACE BETWEEN THE GRAB BAR AND <br />PROJECTING OBJECTS BELOW AND AT THE ENDS SHALL BE 1 112"MINIMUM. THE SPACE BETWEEN THE GRAB BAR AND <br />_ z � __� _ z y__-� <br />I � o I 1 <br />g, THE MAXIMUM PILE HEIGHT SHALL BE 112". <br />C. EXPOSED EDGES OF THE DOORMAT SHALL BE FASTENED TO THE FLOOR SURFACE AND HAVE TRIM ALONG <br />THE ENTIRE LENGTH OF EXPOSED EDGES THAT SHALL COMPLY WITH THE REQUIREMENTS FOR CHANGES IN <br />60" DIAMETER FOR T-SHAPE FOR = - �� <br />'� � <br />d. IN EXISTING BUILDINGS WHEN THE ENFORCING AGENCY DETERMINES THAT COMPLIANCE WITH THESE <br />STANDARDS WOULD CREATE AN UNREASONABLE HARDSHIP. <br />PROJECTING OBJECTS ABOVE SHALL BE 12"MINIMUM. <br />1. THE SPACE BETWEEN THE GRAB BARS AND SHOWER CONTROLS, SHOWER FITTINGS, AND OTHER GRAB BARS <br />59"MIN. AT 59"MIN. AT <br />FLR. MTD. W.C. FLR. MTD. W.C. <br />LEVEL; <br />1. CHANGES IN LEVEL SHALL NOT EXCEED 1/2". <br />180 TURNS 180 TURNS o - <br />ABOVE SHALL BE PERMITTED TO BE 1 1/2" MINIMUM. <br />OR 56" MIN. AT OR 56" MIN. AT <br />2. WHEN CHANGES IN LEVEL DO OCCUR, THEY SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1 <br />42" MIN. < 8" 42" MIN. <br />1 1/2" MIN <br />WALL MTD. W.C. WALL MTD. W.C. <br />UNIT VERTICAL IN 2 UNITS HORIZONTAL (50% SLOPE). <br />CLR. FLR. SPACE CLR. FLR. SPACE <br />3. CHANGES IN LEVEL NOT EXCEEDING 1/4" MAY BE VERTICAL. <br />C. CLEAR FLOOR OR GROUND SPACE FOR WHEELCHAIRS. SHALL COMPLY WITH THE FOLLOWING: <br />GRAB BAR 1 1/4" TO <br />4. CHANGES IN LEVEL GREATER THAN 112" SHALL BE MADE BY MEANS OF A SLOPED SURFACE WITH A <br />1. SIZE AND APPROACH THE MINIMUM CLEAR FLOOR OR GROUND SPACE REQUIRED TO ACCOMMODATE A SINGLE <br />! �� 2" NOMINAL DIAM. <br />FIGURE 9.1 FIGURE 9.2 <br />SLOPE NOT GREATER THAN 1 UNIT VERTICAL IN 20 UNITS HORIZONTAL (5% SLOPE). <br />D. RECESSED DOOR MATS SHALL BE LEVEL WITH THE ADJACENT SURFACE AND BE ADEQUATELY ANCHORED TO <br />WHEELCHAIR IS 30" BY 48". THE CLEAR FLOOR SPACE FOR WHEEL CHAIRS MAY BE POSITIONED FOR FORWARD OR <br />ACCESSIBLE SINGLE ACCOMMODATION ACCESSIBLE SINGLE ACCOMMODATION <br />PREVENT INTERFERENCE WITH WHEELCHAIR TRAFFIC. <br />PARALLEL APPROACH TO AN OBJECT U.N.O.. THE CLEAR FLOOR OR GROUND SPACE FOR WHEELCHAIRS MAY BE A <br />WALL OR PARTITION <br />TOILET WITH SIDE OUT -SWING DOOR TOILET WITH SIDE IN -SWING DOOR <br />PART OF THE KNEE SPACE REQUIRED UNDER SOME OBJECTS. <br />2. RELATIONSHIP R MANEUVERING CLEARANCES TO WHEELCHAIR SPACES ONE FULL UNOBSTRUCTED SIDE OF THE <br />CLEAR FLOOR OR GROUND SPACE FOR A WHEELCHAIR SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE OR <br />CONTROLS & O P E RATION <br />17 <br />GRAB BARS & SHOWER S EAT <br />13 <br />TOILET ROOM LAYOUT <br />9 <br />� <br />GENERAL NOTES <br />1 <br />ADJOIN ANOTHER WHEELCHAIR CLEAR FLOOR OR GROUND SPACE. IF A CLEAR FLOOR SPACE IS LOCATED IN AN <br />LIMITED T B E TIONS 1117A, 1119A, 1121A AND 11 B-DIVISION 4. <br />ALCOVE OR OTHERWISE CONFINED ON ALL OR PART OF THREE SIDES, ADDITIONAL MANEUVERING CLEARANCES <br />SHALL BE PROVIDED AS FOLLOWS: <br />SANITARY FACILITY SIGNS SHALL COMPLY WITH CBC SECTIONS 1127A.7 AND 11 B-703. <br />TOILET ROOM FIXTURES AND ACCESSORIES. SHALL COMPLY WITH CBC SECTIONS 1127A.8, 11 B-603 & 11 B-604 <br />WATER CLOSETS REQUIRED TO BE ACCESSIBLE SHALL COMPLY WITH CBC SECTION 1127A.2.1, 1127A.2.3, ICC A117.1-09 <br />0" CLR. 36" CLR. 48" CLR. 60" CLR. <br />„ ADDITIONAL „ <br />30 2 48 <br />CALIFORNIA'S STANDARDS FOR SIGNAGE ARE MORE STRINGENT THAN SECTION 4.30 OF THE ADA STANDARDS FOR <br />A. TOWEL, SANITARY NAPKINS, WASTE RECEPTACLES. WHERE TOWEL, SANITARY NAPKINS, WASTE <br />A. WATER CLOSET FIXTURES LOCATED IN ACCESSIBLE WATER CLOSET COMPARTMENTS SHALL BE POSITIONED <br />WITH A WALL OR PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE OF THE ACCESSIBLE WATER <br />A. GENERAL. WHEN A BUILDING OR A PORTION OF A BUILDING IS REQUIRED TO BE ACCESSIBLE OR ADAPTABLE, <br />AN A E SIBLE ROUTE SHALL BE PROVIDED TO ALL PORTIONS OF THE BUILDING, ACCESSIBLE BUILDING <br />MANEUVERING <br />ACCESSIBLE DESIGN. THE INFORMATION PROVIDED WITH IN THIS DETAIL IS INTENDED TO SHOW THE MINIMUM <br />RECEPTACLES AND OTHER SIMILAR DISPENSING AND DISPOSAL FIXTURES ARE PROVIDED, AT LEAST ONE OF <br />CLOSET SHALL BE 18" FROM THE SIDE WALL OR PARTITION. <br />ENTRANCES, TO COVERED MULTIFAMILY DWELLING UNITS AND BETWEEN THE BUILDING AND THE PUBLIC WAY. <br />SPACE <br />N <br />SIGNAGE REQUIRED AT SANITARY FACILITY DOORS ONLY TO OBTAIN A BUILDING PERMIT. IDENTIFICATION, <br />DIRECTIONAL AND INFORMATION SIGNS ARE NOT PART OF THE ARCHITECT'S SCOPE OF WORK. <br />EACH TYPE SHALL BE LOCATED WITH ALL OPERABLE PARTS, INCLUDING COIN SLOTS, WITHIN 40" FROM <br />FINISHED FLOOR. A PATH OF TRAVEL NOT LESS THAN 36" IN CLEAR WIDTH SHALL BE PROVIDED TO THESE <br />ACCESSORIES. <br />B. ACCESSIBLE WATER CLOSETS SHALL BE PROVIDED A CLEAR FLOOR SPACE AND MANEUVERING SPACE PER <br />DETAILS 8 AND 9 ON THIS SHEET. <br />C. THE SEAT HEIGHT OF A WATER CLOSET ABOVE FINISH FLOOR SHALL BE 17" MINIMUM AND 19" MAXIMUM <br />1/2" MAX. PILE THICKNESS �. <br />ALL WALKS, HALLS, CORRIDORS, AISLES, SKYWALKS, TUNNELS AND OTHER SPACES THAT ARE PART OF THE <br />ACCESSIBLE ROUTE SHALL COMPLY WITH THE APPLICABLE PROVISIONS OF THE APPLICABLE CODES. AT LEAST <br />ONE ACCESSIBLE ROUTE WITHIN THE BOUNDARY OF THE SITE SHALL BE PROVIDED FROM THE PUBLIC <br />TRANSPORTATION STOPS, ACCESSIBLE PARKING, ACCESSIBLE PASSENGER LOADING ZONES AND PUBLIC <br />A _ <br />u, __ _ <br />1 <br />' A <br />A. ALL ACCESSIBLE TOILET AND BATHING FACILITIES SHALL BE IDENTIFIED BY THE "INTERNATIONAL SYMBOL OF <br />ACCESSIBILITY. SIGNS NEED NOT BE PROVIDED FOR FACILITIES WITHIN A DWELLING UNIT OR GUEST ROOM. <br />B. TOILET PAPER DISPENSERS. SEE DETAIL 10 OF THIS SHEET. SHALL BE LOCATED ON A WALL OR PARTITION <br />CLOSEST TO THE WATER CLOSET WITHIN 7" MINIMUM AND 9" MAXIMUM IN FRONT OF THE WATER CLOSET <br />MEASURED TO THE TOP OF THE SEAT. SEATS SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. SEATS <br />SHALL BE 2" HIGH MAXIMUM. <br />� <br />STREETS OR SIDEWALKS TO THE ACCESSIBLE BUILDING ENTRANCE THEY SERVE. THE ACCESSIBLE ROUTE <br />, , <br />SHALL, TO THE MAXIMUM EXTENT FEASIBLE, COINCIDE WITH THE ROUTE FOR THE GENERAL PUBLIC AND OTHER <br />�_ _„ '�_ _y �- _____\ __,; _________ <br />B. DOORWAYS LEADING TO SANITARY FACILITIES SHALL BE IDENTIFIED BY A GEOMETRIC SYMBOL. GEOMETRIC <br />MEASURED FROM THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE DISPENSER SHALL BE BELOW <br />D. GRAB BARS FOR WATER CLOSETS SHALL COMPLY WITH DETAIL 13 OF THIS SHEET. GRAB BARS SHALL BE <br />BUILDING RESIDENTS. ACCESSIBLE ROUTES SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS, <br />/ <br />SYMBOLS SHALL BE CENTERED HORIZONTALLY ON THE DOOR AT A HEIGHT OF 58" MIMUMUM TO 60" MAXIMUM <br />ABOVE THE FINISH FLOOR OR GROUND SURFACE MEASURED TO THE CENTER OF THE SYMBOL. WHEN A DOOR <br />AND NOT BEHIND THE GRAB BAR, 19" MINIMUM ABOVE THE FINISH FLOOR. DISPENSERS SHALL NOT BE OF A <br />TYPE THAT CONTROLS DELIVERY OR THAT DOES NOT ALLOW CONTINUOUS PAPER FLOW. <br />PROVIDED ON THE SIDE WALL CLOSEST TO THE WATER CLOSET AND ON THE REAR WALL AS INDICATED BELOW. <br />E. FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED CONTROLS SHALL COMPLY <br />IF PILE HEIGHT <br />EXCEEDS THEN EXPOSED EDGE \_ I1 FIRM PAD <br />RESTROOMS, CLOSETS OR OTHER SPACES USED FOR SIMILAR PURPOSES EXCEPT WITHIN AN INDIVIDUAL <br />DWELLING UNIT. ACCESSIBLE ROUTES SHALL BE PROVIDED AS FOLLOWS: <br />1. WHERE MORE THAN ONE ROUTE OF TRAVEL IS PROVIDED, ALL ROUTES SHALL BE ACCESSIBLE. <br />IS PROVIDED THE SYMBOL SHALL BE MOUNTED WITHIN 1 INCH OF THE VERTICAL CENTERLINE OF THE DOOR. <br />C. MIRRORS. WHERE PROVIDED AT LEAST ONE MIRROR SHALL BE ACCESSIBLE. MIRRORS LOCATED ABOVE <br />W F <br />ITH DETAIL 17 OF THIS SHEET EXCEPT THAT THEY SHALL BE LOCATED 44 INCHES MAXIMUM ABOVE THE LOOR. <br />EDGES MUST HAVE <br />ST <br />- - - - - - - ---- - - - - - - ----- - <br />- - - - - - - - -- - - - - - - - - -- - - - - <br />D. SURFACES FOR WHEELCHAIR SPACES GROUND AND FLOOR SURFACES ALONG ACCESSIBLE ROUTES, AND IN <br />EDGES OF ACCESSIBILITY SIGNS SHALL BE ROUNDED, CHAMFERED OR EASED. CORNERS SHALL HAVE A <br />MINIMUM RADIUS OF 1/8". <br />LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING <br />SURFACE 40" ABOVE THE FINISH FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE LAVATORIES OR <br />F. TOILET PAPER DISPENSERS SHALL BE LOCATED AS INDICATED BELOW AND PER DETAIL 14 OF THIS SHEET. <br />G. ACCESSIBLE WATER CLOSETS SHALL BE PROVIDED A CLEAR FLOOR SPACE AND MANEUVERING SPACE PER <br />BEVELED TRIM �' <br />� � <br />2. AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE BUILDING OR FACILITY ENTRANCES WITH <br />ALL ACCESSIBLE SPACES , ELEMENTS AND COVERED MULTIFAMILY DWELLING UNITS. <br />3. AN ACCESSIBLE ROUTE SHALL CONNECT AT LEAST ONE ACCESSIBLE PRIMARY ENTRANCE OF EACH <br />1. MEN'S SANITARY FACILITIES SHALL BE IDENTIFIED WITH AN EQUILATERAL TRIANGLE 1/4" THICK WITH <br />COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING SURFACE 35" MAXIMUM <br />DETAILS 8 AND 9 ON THIS SHEET. <br />2 <br />ACCESSIBLE ROOMS AND SPACES, INCLUDING FLOORS, WALKS, RAMPS ,STAIRS AND CURB RAMPS SHALL BE STABLE, <br />EDGES 12" LONG AND A VERTEX POINTING UP. THE TRIANGLE SYMBOL SHALL CONTRAST WITH THE <br />ABOVE THE FINISH FLOOR. <br />�� <br />COVERED MULTIFAMILY DWELLING UNIT WITH INTERIOR AND EXTERIOR SPACES AND FACILITIES THAT <br />FIRM, SLIP RESISTANT AND SHALL COMPLY WITH THE FOLLOWING: <br />DOOR , EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. <br />D. COAT HOOKS, SHELVES AND MEDICINE CABINETS. COAT HOOKS SHALL BE LOCATED WITHIN ONE OF THE <br />\ 1/i - TRANSITION TRIM <br />SERVE THE UNIT <br />4. WHERE ELEVATORS ARE PROVIDED FOR VERTICAL ACCESS ONLY ONE IS REQUIRED, HOWEVER ALL <br />1. CHANGES IN LEVEL, UP TO 1/4" MAY BE VERTICAL AND WITHOUT EDGE TREATMENT. CHANGES IN LEVEL BETWEEN <br />2. WOMEN'S SANITARY FACILITIES SHALL BE IDENTIFIED WITH A CIRCLE 1/4" THICK AND 121, IN DIAMETER <br />REACH RANGES IDENTIFIED ON DETAIL 22 ON THIS SHEET. SHELVES SHALL BE LOCATED 40" MINIMUM AND <br />54"MIN. <br />--- <br />ELEVATORS PROVIDED SHALL BE ACCESSIBLE. <br />1/4" AND 1/2" SHALE BE BEVELED WITH A SLOPE NO GREATER THAN 1 UNIT VERTICAL IN 2 UNITS HORIZONTAL. <br />AND A VERTEX POINTING UP. THE CIRCLE SYMBOL SHALL CONTRAST WITH THE DOOR , EITHER LIGHT ON <br />48" MAXIMUM ABOVE THE FINISH FLOOR. MEDICINE CABINETS SHALL BE LOCATED WITH A USABLE SHELF NO <br />B. FLOORING. SHALL COMPLY WITH THE REQUIREMENTS OF DETAIL 22, ITEM D OF THIS SHEET. <br />CHANGES IN LEVEL GREATER THAN 112"MUST BE ACCOMPLISHED BY MEANS OF A RAMP, ELEVATOR OR PLATFORM <br />A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. <br />HIGHER THAN 44" MAXIMUM ABOVE FINISH FLOOR. <br />39" - 41" <br />C. RECESSED DOOR MATS. SHALL COMPLY WITH THE REQUIREMENTS OF DETAIL 6 OF THIS SHEET. <br />LIFT. <br />3. UNISEX SANITARY FACILITIES SHALL BE IDENTIFIED BY A CIRCLE 1/4" THICK AND 12" IN DIAMETER WITH A <br />E. SPACES ALLOWANCES AND REACH RANGES IN COMMON USE AREAS. SEE DETAIL 22 ON THIS SHEET FOR THE <br />INTERIOR MATERIAL CHANGES <br />D. PRIMARY ENTRANCES AND GROUND FLOOR EXITS. ALL ENTRANCES AND ALL EXTERIOR GROUND FLOOR EXITS <br />2. IF CARPET OR CARPET TILE IS USED ON A GROUND OR FLOOR SURFACE, IT SHALL BE SECURELY ATTACHED; HAVE <br />1/4" THICK TRIANGLE SUPERIMPOSED ON THE CIRCLE AND WITHIN THE 121, DIAMETER. THE TRIANGLE <br />REQUIRED CLEAR SPACE, ALLOWABLE REACH RANGES AND REQUIREMENTS FOR CONTROLS AND <br />36" MIN. 12" MAX. 42"MIN. <br />A. MATERIAL CHANGES IN HEIGHT AT INTERIOR DOOR THRESHOLDS SHALL NOT EXCEED 1/2". <br />SHALL BE ACCESSIBLE. <br />E. SEPARATE DWELLING UNIT ENTRANCES. WHEN A GROUND -FLOOR DWELLING UNIT OF A BUILDING HAS A <br />FIRM CUSHION, PAD OR BACKING OR NO CUSHION, PAD OR BACKING; AND HAVE A LEVEL LOOP, TEXTURED LOOP, <br />SYMBOL SHALL CONTRAST WITH THE CIRCLE SYMBOL, EITHER LIGHT ON A DARK BACKGROUND OR DARK <br />OPERATING MECHANISMS. <br />B. THRESHOLDS WITH A CHANGE IN HEIGHT OF NOT MORE THAN 1/4" MAYBE VERTICAL. <br />SEPARATE ENTRANCE, EACH SUCH GROUND -FLOOR DWELLING UNIT SHALL BE SERVED BY AN ACCESSIBLE <br />LEVEL -CUT PILE, OR LEVEL-CUT/UNCUT PILE TEXTURE. THE MAXIMUM PILE HEIGHT SHALL BE 1/2". EXPOSED EDGES <br />ON A LIGHT BACKGROUND. THE CIRCLE SYMBOL SHALL CONTRAST WITH THE DOOR , EITHER LIGHT ON A <br />12" MIN. 24" MIN. <br />z <br />ROUTE EXCEPT WHERE THE SITE TERRAIN PROHIBITS AN ACCESSIBLE ROUTE (SEE CBC SECTION 1150A). <br />OF THE CARPET SHALL BE FASTENED TO THE FLOOR SURFACES AND HAVE TRIM ALONG THE ENTIRE LENGTH OF <br />DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. <br />TOILET <br />1= � <br />F. MULTIPLE ENTRANCES. ONLY ONE ENTRANCE TO COVERED MULTIFAMILY BUILDINGS IS REQUIRED TO BE <br />THE EXPOSED EDGE. CARPET EDGE TRIM SHALL COMPLY WITH ITEM 1 ABOVE <br />3. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED 112". WHEN CHANGES IN LEVEL <br />PAPER <br />� <br />> SQ BEVEL <br />ACCESSIBLE TO ANY ONE GROUND FLOOR OF A BUILDING, EXCEPT IN CASES WHERE AN INDIVIDUAL DWELLING <br />UNIT HAS A SEPARATE EXTERIOR ENTRANCE. WHERE THE BUILDING CONTAINS CLUSTERS OF DWELLING UNITS <br />DISPENSER <br />_ <br />� 2 <br />DO OCCUR, THEY SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1 UNIT VERTICAL IN 2 UNITS HORIZONTAL. <br />CHANGES IN LEVEL NOT EXCEEDING 1/4" MAY BE VERTICAL. <br />4. IF GRATINGS ARE LOCATED IN WALKING SURFACES, THEN THEY SHALL BE LIMITED TO SPACES NO GREATER THAN <br />i <br />FINISH FLOOR EVEN <br />1 � <br />WITH EACH CLUSTER SHARING A DIFFERENT EXTERIOR ENTRANCE, MORE THAN ONE ENTRANCE MAY BE <br />REQUIRED TO BE ACCESSIBLE AS DETERMINED BY ANALYSIS OF THE SITE TERRAIN. IN EVERY CASE, THE <br />ACCESSIBLE ENTRANCE SHALL BE ON AN ACCESSIBLE ROUTE TO THE COVERED MULTIFAMILY DWELLING UNIT <br />112"WIDE IN ONE DIRECTION . IF GRATINGS HAVE ELONGATED OPENINGS, THEY SHALL BE PLACED SO THAT THE <br />O _ _ • • <br />o =' 24"MIN. <br />COMPRESSED CARPET 1/2" �. <br />IT SERVES. <br />LONG DIMENSION IS PERPENDICULAR TO THE DOMINATE DIRECTION OF TRAVEL. <br />'� o o <br />`' <br />MAX. BELOW THRESHOLD <br />G. INTERIOR WIDTHS AND LENGTHS. SHALL COMPLY WITH THE REQUIREMENTS OF DETAIL 22, ITEM A OF THIS <br />= <br />DOOR THRESHOLD <br />HEET. IF A PER N IN A WHEEL CHAIR MUST MAKE A TURN AROUND A CORNER OR OBSTRUCTION THE <br />E. REACH RANGES SHALL COMPLY WITH THE FOLLOWING FIGURES: <br />M M �, <br />X <br />a � w <br />ACCESSIBLE ROUTE SHALL COMPLY WITH DETAIL 22, ITEM B OF THIS SHEET. <br />"X" <br />a, <br />�, M M <br />,1, <br />mi m <br />H. CHANGES IN LEVEL NOT EXCEEDING 1/2". ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL <br />_ <br />i,_o„ <br />`' M <br />� T' _ 9" � � <br />" - <br />�� -� <br />24 - m <br />MAT CARPETING MUST CONSIST OF: <br />A. LEVEL LOOP <br />NOT EXCEED 1/2". WHEN CHANGES IN LEVEL DO OCCUR, THEY SHALL BE BEVELED WITH A SLOPE NO GREATER <br />THAN 1 UNIT VERTICAL IN 2 UNITS HORIZONTAL (50% SLOPE). CHANGES IN LEVEL NOT EXCEEDING 1/4" MAY BE <br />VERTICAL. <br />N �o Q . � <br />MEWS DOOR WOMEN'S DOOR UNISEX DOOR <br />B. TEXTURED LOOP <br />I. CHANGES IN LEVEL GREATER THAN 1/2". CHANGES IN LEVEL GREATER THAN 1/2" SHALL BE MADE BY MEANS OF <br />o <br />z <br />o � � -- = = o w <br />SIGNAGE SIGNAGE SIGNAGE <br />C. LEVEL CUT PILE <br />D. LEVEL CUTIUNCUT PILE <br />A SLOPED SURFACE WITH A SLOPE NOT GREATER THAN 1 UNIT VERTICAL IN 20 UNITS HORIZONTAL (5 /° SLOPE), <br />OR A CURB RAMP PER CBC SECTION 1112A, A RAMP PER CBC SECTION 1114A EXTERIOR RAMPS OR 1122A <br />� 4 = � � � - > - c- - �, <br />_ - " x <br />18" REAR WALL SIDE WALL <br />INTERIOR RAMPS, ELEVATOR PER CBC SECTION 3003 OR PLATFORM WHEELCHAIR LIFT PER CBC SECTION <br />1124A. WHEN STAIRS ARE LOCATED ALONG OR ADJACENT TO AN ACCESSIBLE ROUTE THEY SHALL COMPLY <br />PARALLEL APPROACH SIDE REACH FORWARD APPROACH FORWARD REACH <br />WITH CBC SECTION 1115A EXTERIOR STAIRWAYS OR 1123A INTERIOR STAIRWAYS. <br />' THE TOP OF WASHING MACHINES AND CLOTHES DRYERS ARE PERMITTED TO BE 36" MAXIMUM ABOVE THE FINISH FLOOR. <br />SPACE & REACH RQMTS. <br />22 <br />SANITARY FACILITY SIGNAGE <br />18 <br />FIXTURES AND ACCESSORIES <br />14 <br />WATER CLOSET <br />10 <br />LANDINGS & THRESHOLDS <br />6 <br />ACCESSIBLE ROUTE <br />2 <br />COMMON ACCESSIBLE LAUNDRY ROOMS SHALL COMPLY WITH CBC SECTIONS 1127A.10 AND 11 B-611 <br />SHOWERS REQUIRED TO BE ACCESSIBLE SHALL COMPLY WITH CBC SECTIONS 1127A.5.3 AND 11 B-608. <br />ACCESSIBLE URINALS SHALL COMPLY WITH CBC SECTION 1127A.2.4 AND 11 B-605. <br />MULTIPLE -ACCOMMODATION TOILET FACILITIES SHALL COMPLY WITH CBC SECTIONS 1127A.2.1 AND 11 B-604. <br />DOORS THAT PROVIDE ACCESS TO COMMON USE AREAS SHALL COMPLY WITH SECTION 1126A AND 11 B-404. THIS SHEET FOR <br />LANDINGS AND THRESHOLDS. THE COMMON USE OR PUBLIC SIDE OF PRIMARY ACCESS DOORS TO DWELLING UNITS SHALL <br />WHERE COMMON USE LAUNDRY ROOMS ARE PROVIDED AT LEAST ON TYPE OF APPLIANCE PROVIDED IN EACH <br />A. SHOWERS SHALL BE CONSISTENT WITH ONE OF THE FOLLOWING SIZES AND SHALL BE MEASURED FROM THE FACE OF WALL SURFACES: <br />A. URINALS SHALL BE FLOOR MOUNTED STALL TYPE OR WALL HUNG WITH THE RIM 17" MAXIMUM ABOVE THE <br />)1/2" <br />A. TURNING SPACE OF SUFFICIENT SIZE TO INSCRIBE A CIRCLE WITH A DIAMETER NOT LESS THAN 60" OR A <br />COMPLY WITH NOTES F AND G BELOW. <br />LAUNDRY AREA SHALL BE ACCESSIBLE AND SHALL BE ON AN ACCESSIBLE ROUTE. SUCH APPLIANCES SHALL <br />INCLUDE CLOTHES WASHING MACHINES, DRYERS, SOAP DISPENSERS AND ANY RELATED FEATURES SUCH AS <br />1. ROLL -IN SHOWER 60" MIN. IN WIDTH BY 30" MIN. IN DEPTH WITH A FULL OPENING WIDTH ON THE LONG THE SIDE SEE FIGURE 16.1 BELOW. 27" MAX. <br />FINISH FLOOR OR GROUND. URINALS SHALL BE 13 DEEP MINIMUM MEASURED FROM THE OUTER FACE OF <br />T-SHAPED SPACE SHALL BE PROVIDED WITHIN THE TOILET FACILITY. THE WHEECHAIR TURNING SPACE SHALL <br />A. DOORWAYS SHALL PERMIT THE INSTALLATION OF A DOOR NOT LESS THAN 36 IN WIDTH NOT LESS THAN 80 IN HEIGHT <br />WASH SINKS TABLES AND STORAGE AREAS. <br />2. ALTERNATE ROLL -IN SHOWER, 60" MIN. IN WIDTH BY 36" IN DEPTH WITH AN ENTRANCE OPENING WIDTH OF 36", SEE FIGURE 16.2 BELOW. <br />19 MIN. <br />" <br />THE URINAL RIM TO THE BACK OF THE FIXTURE. <br />1 <br />COMPLY WITH SECTION 1138A.1.3.OTHER THAN THE DOOR TO THE ACCESSIBLE WATER CLOSET COMPARTMENT, <br />AND PROVIDE A CLEAR OPENING OF NOT LESS THAN 32 IN WIDTH MEASURED WITH THE DOOR OR DOORS POSITIONED <br />WHERE LAUNDRY ROOMS ARE PROVIDED ON FLOORS OF AN ELEVATOR BUILDING, EACH LAUNDRY ROOM SHALL <br />3. ALTERNATE ROLL -IN SHOWER WITH OPTIONAL ENCLOSURE 60 MIN. IN WIDTH BY 36 MIN. IN DEPTH AS LONG AS THE ENTRANCE <br />C. WHERE URINALS ARE PROVIDED, AT LEAST ONE SHALL HAVE A CLEAR FLOOR SPACE OF 30 X 48 IN FRONT OF <br />A DOOR IN ANY POSITION MAY ENCROACH INTO THIS SPACE BY NOT MORE THAN 12 . <br />AT AN ANGLE OF 90-DEGREES FROM THE CLOSED POSITION. <br />OPENING WIDTH IS A MIN. 36", SEE FIGURE 16.3 BELOW. <br />THE URINAL TO ALLOW FORWARD APPROACH. THE CLEAR FLOOR SPACE SHALL COMPLY WITH DETAIL 22 OF <br />B. DOORS SHALL NOT SWING INTO THE FLOOR SPACE REQUIRED FOR ANY FIXTURE. REQUIRED CLEAR FLOOR <br />B, DOORS SHALL BE CAPABLE OF OPENING AT LEAST 90 DEGREES.. <br />BE ACCESSIBLE. WHERE THERE IS ONE LAUNDRY ROOM ON A GROUND FLOOR IN EACH BUILDING EACH LAUNDRY <br />B. THRESHOLDS IN ROLL -IN TYPE SHOWERS SHALL BE 1/2 HIGH MAX. CHANGES IN LEVEL UP T0114 MAY BE VERTICAL AND WITHOUT EDGE <br />THIS SHEET. <br />SPACE CLEARANCE AT FIXTURES AND TURNING SPACE SHALL BE PERMITTED TO OVERLAP. SEE FIGURE 8.2-B <br />C. A PAIR OF DOORS MANUAL OR AUTOMATIC MUST HAVE AT LEAST ONE LEAF THAT PROVIDES A CLEAR WIDTH OF NOT <br />ROOM SHALL BE ACCESSIBLE. WHERE THERE IS A LAUNDRY ROOM ON THE GROUND FLOOR OF A BUILDING AND <br />TREATMENT. CHANGES IN LEVEL BETWEEN 114"AND 112"SHALL BE BEVELED WITH A SLOPE NO GREATER THAN ONE UNIT VERT. IN 2 UNITS <br />D. FLUSH CONTROLS SHALL HAND OPERATED OR AUTOMATIC. HAND OPERATED FLUSH CONTROLS SHALL <br />BELOW ACCESSIBLE COMPARTMENT WITH SIDE IN -SWING DOOR. <br />LESS THAN 32 MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90-DEGREES FROM ITS CLOSED POSITION. <br />ANOTHER LOCATED IN A BASEMENT, IT IS ACCEPTABLE TO ONLY HAVE THE GROUND FLOOR LAUNDRY <br />HORIZ. <br />COMPLY WITH DETAIL 17 OF THIS SHEET EXCEPT THAT THE FLUSH CONTROL SHALL BE MOUNTED AT A <br />C. PROVIDE A MINIMUM OF ONE ACCESSIBLE WATER CLOSET IN COMPLIANCE WITH THE REQUIREMENTS WITHIN <br />AT DOUBLE EGRESS DOORS EACH LEAF MUST PROVIDE THE CLEAR WIDTH. <br />ACCESSIBLE. <br />C. SHOWER COMPARTMENT FLOOR SURFACES SHALL BE STABLE, FIRM AND SLIP RESISTANT. THE MAXIMUM SLOPE OF THE FLOOR SHALL BE <br />MAXIMUM HEIGHT OF 44" ABOVE FINISH FLOOR. <br />THIS DETAIL AND DETAIL 10 ON THIS SHEET. PROVIDE AT LEAST 5 PERCENT OF LAVATORIES, BUT NOT LESS <br />D. THE WIDTH OF ANY COMPONENT OF THE EGRESS SYSTEM SHALL NOT BE LESS THAN THE MINIMUM WIDTH REQUIRED <br />A. THERE SHALL BE A MINIMUM CLEAR SPACE 30" PERPENDICULAR BY 48" PARALLEL IN FRONT OF CLOTHES <br />1/4" PER FOOT IN ANY DIRECTION. WHEN DRAINS ARE PROVIDED, GRATE OPENINGS SHALL BE 1/4" MAXIMUM AND LOCATED FLUSH WITH THE <br />FLOOR SURFACE. I- <br />THAN ONE LAVATORY, SHALL BE ACCESSIBLE IN COMPLIANCE WITH DETAIL 12 OF THIS SHEET. <br />D. WATER CLOSETS REQUIRED TO BE ACCESSIBLE SHALL COMPLY WITH THE FOLLOWING: <br />BY SECTION 1005. <br />E. PER CBC SECTION 1010.1.5, THERE SHALL BE A FLOOR OR LANDING ON EACH SIDE OF THE DOOR. SUCH FLOOR OR <br />WASHERS AND DRYERS REQUIRED TO BE ACCESSIBLE. THERE SHALL BE A MINIMUM CLEAR SPACE 30" BY 48" <br />T- Y <br />D. WHERE, WITHIN THE SAME FUNCTIONAL AREA, TWO OR MORE ACCESSIBLE SHOWERS ARE PROVIDED, THERE SHALL BE AT LEAST ONE U <br />1. THE CENTERLINE OF THE ACCESSIBLE WATER CLOSET SHALL BE 18" MAXIMUM FROM THE SIDE WALL OR <br />LANDING SHALL BE THE SAME ELEVATION ON EACH SIDE OF THE DOOR. LANDINGS SHALL BE LEVEL EXCEPT FOR <br />EXTERIOR LANDINGS WHICH ARE PERMITTED TO HAVE A SLOPE NOT TO EXCEED 1/4" VERTICAL TO 12" HORIZONTAL <br />PROVIDED FOR AT LEAST ONE TYPE OF FIXTURE OR APPLIANCE PROVIDED IN THE LAUNDRY ROOM E.G. <br />( � <br />i `. <br />SHOWER CONSTRUCTED OPPOSITE HAND FROM THE OTHER OR OTHERS (THAT IS, ONE LEFT-HAND CONTROL VERSUS ONE RIGHT-HAND � � ,\ ¢ <br />PARTITION. THE CENTERLINE OF THE ACCESSIBLE WATER CLOSET LOCATED IN A AMBULATORY ACCESSIBLE <br />(2-PERCENT SLOPE). SEE DETAIL 6 FOR ADDITIONAL INFORMATION. <br />SOAP DISPENSERS, WASH SINKS, TABLES AND STORAGE AREAS). <br />CONTROL). I Of <br />30" MINIMUM <br />COMPARTMENT, REQUIRED BY NOTE F BELOW, SHALL BE 18" FROM THE SIDE WALL OR PARTITION. <br />F. MANEUVERING CLEARANCES AT DOORS <br />B. CLOTHES WASHERS AND DRYERS INCLUDING STACKED CLOTHES WASHERS AND DRYERS REQUIRED TO BE <br />ACCESSIBLE SHALL HAVE CONTROLS COIN SLOTS) WITHIN THE REACH RANGE OF A SEATED <br />E. WATER CONTROLS SHALL BE OF A SINGLE -LEVER DESIGN, OPERABLE WITH ONE HAND, AND SHALL NOT REQUIRE TIGHT GRASPING, 1 \ c� <br />� <br />_y <br />2. PROVIDE A CLEAR FLOOR SPACE AND MANEUVERING SPACE IN COMPLIANCE WITH FIGURES 8.1A, 8.1 B, 8.2A <br />1. THE LEVEL FLOOR OR LANDING OF AN EXIT DOOR SHALL HAVE A LENGTH IN THE DIRECTION OF THE DOOR SWING <br />(INCLUDING <br />PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE THE CONTROLS SHALL BE NO GREATER THAN 5 LBS. THE :: \ � z <br />� ~ <br />-------------I <br />OR 8.26 AT THE ACCESSIBLE WATER CLOSET COMPARTMENT AND FIGURE 3 WHEN A AMBULATORY <br />OF AT LEAST 60" AND A LENGTH OPPOSITE OF THE DOOR SWING OF AT LEAST 44" MEASURED AT RIGHT ANGLES TO <br />USER. CONTROLS SHALL BE LOCATED NO HIGHER THAN 48"AND NO LOWER THAN 15", ABOVE THE FINISH <br />CENTERLINE OF THE CONTROLS SHALL BE LOCATED 39" TO 41" ABOVE THE SHOWER FLOOR AND LOCATED WITHIN THE SHOWER PER THE = <br />I - z <br />� <br />ACCESSIBLE COMPARTMENT IS REQUIRED. <br />THE PLANE OF THE DOOR IN ITS CLOSED POSITION. SEE FIGURES BELOW. <br />FLOOR MEASURED TO THE CENTER OF THE GRIP. IF THE REACH IS OVER AN OBSTRUCTION FOR EXAMPLE, A <br />( <br />FIGURES WITHIN. . C ) � <br />M O <br />i r <br />E. ACCESSIBLE WATER CLOSET COMPARTMENT DOORS SHALL COMPLY WITH THE FOLLOWING: <br />2. THE WIDTH OF LEVEL AREA ON THE SIDE TO WHICH THE DOOR SWINGS SHALL EXTEND AT LEAST 18" PAST THE <br />WASHER OR DRYER BETWEEN 20' AND 25 IN DEPTH THE MAXIMUM HEIGHT IS REDUCED TO 44 FOR <br />" <br />z <br />- <br />F. A SHOWER SPRAY UNIT WITH A HOSE 59" INCHES LONG MINIMUM THAT CAN BE USED BOTH AS A FIXED POSITION SHOWER HEAD AND AS A � z _ � <br />I I <br />I I 1 <br />1. THE COMPARTMENT DOOR SHALL BE EQUIPPED WITH AN AUTOMATIC CLOSING DEVISE, AND SHALL HAVE A <br />STRIKE EDGE OF THE DOOR FOR INTERIOR DOORS AND AT LEAST 24" PAST THE STRIKE EDGE OF THE DOOR FOR <br />EXTERIOR DOORS. <br />FORWARD APPROACH, OR 46" FOR SIDE APPROACH, PROVIDED THAT THE OBSTRUCTION IS NO MORE THAN <br />24" IN DEPTH. CONTROLS THAT DO NOT SATISFY THESE SPECIFICATIONS ARE ACCEPTABLE, PROVIDED THAT <br />HAND HELD SHOWER SHALL BE PROVIDED. THE SHOWER SPRAY UNIT SHALL HAVE AN ONIOFF CONTROL WITH A NON POSITIVE SHUT OFF. - a� " <br />M _ 6" MAX. O <br />\ i I <br />� , <br />I 1 1 <br />CLEAR, UNOBSTRUCTED OPENING WIDTH OF 32"WHEN LOCATED AT THE END AND 34"WHEN LOCATED AT <br />3. THE FOLLOWING PROVISIONS SHALL APPLY TO SWINGING DOORS WITH A FRONT APPROACH: <br />PULL SIDE _ <br />I + D00 2" <br />I 18" AT INTERIOR DOORS <br />COMPARABLE CONTROLS OR OUTLETS, THAT PROVIDE THE SAME FUNCTIONS, ARE PROVIDED WITHIN THE <br />SAME AREA AND ARE ACCESSIBLE. CONTROLS SHALL BE OPERABLE WITH ONE HAND AND NOT REQUIRE <br />IF AN ADJUSTABLE HEIGHT SHOWER HEAD OR A VERTICAL BAR IS USED, THE BAR SHALL BE INSTALLED SO AS NOT TO OBSTRUCT THE USE M _ . <br />M - <br />OF GRAB BARS. SHOWER SPRAY UNITS SHALL DELIVER WATER THAT IS 120'F MAXIMUM. WHERE SUBJECT TO EXCESSIVE VANDALISM, TWO O <br />FIXED SHOWER HEADS SHALL BE INSTALLED INSTEAD OF A HAND-HELD SPRAY UNIT IN FACILITIES THAT ARE NOT TRANSIENT LODGING ~ <br />� i I <br />I I <br />� I I <br />1 <br />z I I 1 <br />I �� I 1 <br />THE SIDE WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. SEE ALL <br />FIGURES BELOW. <br />2. THE INSIDE AND OUTSIDE OF THE COMPARTMENT DOOR SHALL BE EQUIPPED WITH ALOOP OR U-SHAPED <br />TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. SEE DETAIL 22 ON THIS SHEET. <br />GUEST ROOMS. EACH SHOWER HEAD SHALL BE INSTALLED SO IT CAN BE OPERATED INDEPENDENTLY OF THE OTHER AND SHALL HAVE <br />co I i <br />PARTITION <br />HANDLE IMMEDIATELY BELOW THE LATCH. THE LATCH SHALL BE FLIP -OVER STYLE, SLIDING OR OTHER <br />I WIDTH MI <br />MIN. <br />C. WASHING MACHINES AND CLOTHES DRYERS IN ACCESSIBLE COMMON USE LAUNDRY ROOMS SHALL BE <br />FRONT LOADING. <br />SWIVEL ANGLE ADJUSTMENTS, BOTH VERTICALLY AND HORIZONTALLY. J, 60" MIN. FINISH TO FINISH CLEAR <br />G. A FOLDING SEAT SHALL BE SIZED AND LOCATED AS SHOWN BELOW. SEE DETAIL 13 THIS SHEET FOR SEAT STRENGTH AND MOUNTING <br />I I <br />I i I OR WALL I I <br />I I 1 <br />WHEN <br />HARDWARE NOT REQUIRING THE USER TO GRASP OR TWIST. <br />3. EXCEPT FOR DOOR -OPENING WIDTHS AND DOOR SWINGS, A CLEAR, UNOBSTRUCTED ACCESS OF NOT LESS <br />o � <br />co - <br />z 24 AT EXTERIOR DOORS 1 <br />D. DEEP UTILITY SINKS SHALL MEET THE REQUIREMENTS FOR FAUCET CONTROLS (SEE DETAIL 12 THIS SHEET) <br />REQUIREMENTS. <br />I <br />OCCURS 1 <br />THAN 44 INCHES SHALL BE PROVIDED TO WATER CLOSET COMPARTMENTS DESIGNED FOR USE BY PERSONS <br />MIN. � <br />AND A 30"X48"CLEAR FLOOR SPACE PARALLEL TO THE SINK SHALL BE PROVIDED. <br />H. GRAB BARS SHALL BE LOCATED ON WALLS ADJACENT TO AND OPPOSITE THE SEAT. GRAB BARS SHALL ALSO COMPLY WITH THE DIAMETER, <br />WITH DISABILITIES, AND THE SPACE IMMEDIATELY IN FRONT OF A WATER CLOSET COMPARTMENT SHALL NOT <br />_ _ _ _ � = <br />E. FOLDING TABLES SHALL BE PROVIDED WITH THE TABLE TOP BETWEEN 28" TO 34" ABOVE THE FLOOR. KNEE <br />SPACE SHALL BE PROVIDED BELOW IN COMPLIANCE WITH DETAIL 12 THIS SHEET. <br />SHOWER BACK CONTROL WALL ELEVATION FOR FIGURES 16.1 AND 16.3 <br />LOADING AND PROJECTION REQUIREMENTS OF DETAIL 13 ON THIS SHEET. GRAB BARS SHALL BE MOUNTED BETWEEN A MINIMUM 33" AND A <br />MAXIMUM 36" ABOVE THE SHOWER FLOOR. L-SHAPED GRAB BARS ARE PERMISSIBLE OR MULTIPLE GRAB BARS INSTALLED AT THE SAME <br />� � I <br />i,/ `� i i <br />`----- -----� I <br />BE LESS THAN 48 INCHES AS MEASURED AT RIGHT ANGLES TO COMPARTMENT DOOR IN ITS CLOSED <br />POSITION. MANEUVERING SPACE OUTSIDE THE COMPARTMENT DOOR SHALL COMPLY WITH DETAIL 4, NOTE <br />z <br />� <br />DOOR L____�J <br />WIDTH PUSH SIDE <br />HEIGHT AND NO MORE THAN 6" FROM ADJACENT WALLS. GRAB BARS MAYBE MOUNTED ON WALLS ADJACENT TO AND OPPOSITE THE SEAT, <br />z � - I <br />F, OF THIS SHEET. MANEUVERING SPACE INSIDE THE COMPARTMENT SHALL COMPLY WITH THE THE FIGURES <br />- <br />BUT SHALL NOT EXTEND TO INCLUDE THAT PORTION OF WALL OVER THE SEAT. 60" MIN. FINISH TO FINISH CLEAR <br />N � �� � L----- __J <br />BELOW. <br />ADDITIONAL MANEUVERING SPACE IF A DOOR <br />I. WHEN A SOAP DISH IS PROVIDED, IT SHALL BE LOCATED ON THE CONTROL WALL AT A MAXIMUM HEIGHT OF 40"ABOVE THE SHOWER FLOOR, <br />� - <br />4. TOE CLEARANCE SHALL BE PROVIDED ON AT LEAST ONE SIDE PARTITION OF AT LEAST 9" HIGH AND 6" DEEP <br />L _ J IS PROVIDED WITH BOTH CLOSER AND LATCH <br />AND WITHIN THE 27" MAXIMUM REACH LIMITS FROM THE SEAT. BACK CONTROL WALL <br />M o <br />MEASURED FROM THE COMPARTMENT -SIDE FACE OF THE PARTITION, EXCLUSIVE OF PARTITION SUPPORT <br />4. THE FOLLOWING PROVISIONS SHALL APPLY TO SWINGING DOORS WITH A HINGE SIDE APPROACH: <br />J. ENCLOSURES, WHEN PROVIDED FOR SHOWER COMPARTMENTS, SHALL NOT OBSTRUCT CONTROLS OR TRANSFER FROM WHEELCHAIRS <br />MEMBERS. PARTITION COMPONENTS AT TOE CLEARANCES SHALL BE SMOOTH WITHOUT SHARP EDGES OR <br />ONTO SHOWER SEATS. - - <br />J i ^ I <br />ABRASIVE SURFACES. TOE CLEARANCE IS NOT REQUIRED IN COMPARTMENTS GREATER THAN 66" WIDE. <br />F. IN LARGE TOILET ROOMS, WHERE SIX OR MORE STALLS ARE PROVIDED WITHIN A MULTIPLE- ACCOMMODATION <br />PULL SIDE - - <br />22" D00 <br />MIN WIDTH <br />I <br />EQ. EQ. <br />TOILET ROOM, IN ADDITION TO THE WATER CLOSET COMPARTMENT REQUIRED ABOVE, PROVIDE AT LEAST ONE <br />� <br />z U) � z ¢ <br />27" MAX. � z w I o Q /__/ w <br />22 23 .< M o w i Jo � I o <br />31"CLEAR 13 112"MIN. <br />17" MAX. <br />AMBULATORY ACCESSIBLE COMPARTMENT. THE AMBULATORY ACCESSIBLE COMPARTMENT SHALL BE 36" WIDE <br />WITH AN OUTWARD SWINGING SELF CLOSING DOOR AND PARALLEL GRAB BARS COMPLYING WITH DETAIL 13 OF <br />THIS SHEET INSTALLED ON EACH SIDE WALL OF THE COMPARTMENT. SEE FIGURE 8.3 BELOW. <br />z 1 z <br />� � <br />19"MIN. N = I MAXIMUM <br />- U) F <br />48" MIN. 48" MIN. <br />LOCATE END DOOR DIAGONAL <br />---- 00 <br />18" z I 1 1/4" : V-0" SLOPE <br />`1 <br />END DOOR END DOOR <br />MANEUVERIN TO THE WATER CLOSET MANEUVERING <br />DOOR 36"MIN--------- <br />WIDTH PUSH SIDE <br />LAUNDRY ROOMS <br />2 3 <br />_ ___-_'________________ ___ <br />i � i \`. 1/2" MAX. THRESHOLD 7�' <br />1 <br />I z F- -- I 1 <br />1 o w l� z 1 `• " CLEAR <br />`n <br />URINAL 11 <br />ACCESSIBLE LAVATORIES SHALL COMPLY WITH CBC SECTIONS 1127A.3,1138A.2 AND 11 B-606. <br />___ rL r-- <br />o cw� -- -- j 1 °� o p C> _ I �o <br />o z M � �, 1 1 o z a N - ✓ `� <br />, - z 1 ,< ; i z > ,Y z �a' <br />w � w .< I 1 w U_ � w ,/ `� <br />I <br />r-� ADDITIONAL MANEUVERING SPACE IF A DOOR <br />�_� IS PROVIDED WITH BOTH CLOSER AND LATCH <br />5. THE FOLLOWING PROVISIONS SHALL APPLY TO SWINGING DOORS WITH A LATCH SIDE APPROACH: <br />STORAGE SHALL COMPLY WITH CBC SECTIONS 1127A.11 AND 11 B-811. <br />IF FIXED STORAGE FACILITIES SUCH AS CABINETS AND SHELVES, CLOSETS AND DRAWERS ARE PROVIDED WHERE ACCESS <br />x � 1 �� <br />I 1 a FLOOR <br />v M I SPACE 1 <br />LAVATORY FIXTURES, VANITIES AND BUILT-IN LAVATORIES SHALL COMPLY WITH THE FOLLOWING: <br />A. LAVATORIES, WHEN LOCATED ADJACENT TO A SIDE WALL OR PARTITION, SHALL BE A MINIMUM OF 18" TO THE <br />_ z J _ z �, J f / <br />o Q J M �' o � J M " ,' I <br />= v �_ ---� v __� ___i <br />PULL SIDE <br />-------� D00 24" <br />r-------� <br />IS REQUIRED (BY CBC SECTIONS 1.8.2.1.2 AND 1102A), AT LEAST ONE OF EACH TYPE OF FACILITY PROVIDED SHALL COMPLY <br />= ' `. <br />CENTERLINE OF THE FIXTURE. ALL LAVATORIES DESIGNATED TO BE ACCESSIBLE SHALL BE A MINIMUM 17" IN <br />5g"MIN. AT / 36' MIN. 59"MIN. AT <br />I 1 WIDTH MIN <br />z z 1 <br />WITH THE FOLLOWING ITEMS. ADDITIONAL STORAGE MAY BE PROVIDED OUTSIDE OF THE REACH RANGES. <br />m I -' 1 I <br />CD I 1 I -� 1 <br />HORIZONTAL DEPTH AND MOUNTED WITH THE RIM OR COUNTER EDGE NO HIGHER THAN 34" ABOVE THE <br />' ' DOOR PERMITTED ' ' ' <br />= 1 <br />- <br />A. A CLEAR FLOOR SPACE AT LEAST 30" BY 48" COMPLYING WITH CBC SECTION 1138A.14 THAT ALLOWS EITHER A <br />� z I 1 I <br />I I � � � 1 <br />z 1 1 � z i <br />21/2" MAX. w o--------------------------� <br />FINI H FL RAND WITH VERTI AL LEARAN E MEA RED FR M THE B TT M APR N R TIDE <br />S 00 C C C SU 0 0 0 0 0 OU S <br />BOTTOM EDGE OF THE LAVATORY OF 29" REDUCING TO 27" AT A POINT LOCATED 8" BACK FROM THE FRONT <br />FLR. MTD. W.C. WHEN DR. FLR. MTD. W.C. <br />TO SWING OVER <br />OR 56"MIN. AT SWINGS IN OR 56"MIN. AT <br />HATCHED PORTION <br />�� 1 z I I <br />z -I <br />1 � � 1 1 <br />FORWARD OR PARALLEL APPROACH BY A PERSON USING A WHEELCHAIR SHALL BE PROVIDED AT ACCESSIBLE <br />0 M z_ � z <br />EDGE. IN ADDITION, A MINIMUM 9"HIGH TOE CLEARANCE MUST BE PROVIDED EXTENDING BACK TOWARD THE <br />WALL MTD. W.C. OF MANEUVERING WALL MTD. W.C. <br />CO . 1 1 <br />� <br />STORAGE FACILITIES. <br />z 15" -16" Q w 60" MIN. <br />o <br />WALL TO A DISTANCE NO MORE THEN 6" FROM THE BACK WALL. THE TOE CLEARANCE SPACE MUST BE FREE <br />CLR. FLR. SPACE SPACE CLR. FLR. SPACE <br />DOOR 24"-------� <br />B. ACCESSIBLE STORAGE SPACES AND CLOTHES RODS SHALL BE WITHIN AT LEAST ONE OF THE REACH RANGES <br />_ <br />a 6" MAX. 6' M 0- a <br />0 M � o <br />OF EQUIPMENT AND OBSTRUCTIONS; SEE FIGURE B BELOW. <br />B. A CLEAR FLOOR SPACE 30" BY 48" COMPLYING WITH THE FIGURES BELOW AND DETAIL 22, NOTE D, OF THIS <br />FIGURE 8.1 A FIGURE 8.1 B <br />ACCESSIBLE COMPARTMENT WITH ACCESSIBLE COMPARTMENT WITH <br />WIDTH MIN L-------J <br />PUSH SIDE <br />SPECIFIED IN SECTION 1138A.3. <br />C. HARDWARE FOR ACCESSIBLE STORAGE FACILITIES SHALL COMPLY WITH CBC SECTION 1138A.4. TOUCH LATCHES <br />SHOWER SEAT o0 FIGURE 16.1 ROLL -IN SHOWER, PLAN VIEW <br />SHEET SHALL BE PROVIDED IN FRONT OF AND CENTERED ON ACCESSIBLE LAVATORIES TO ALLOW FORWARD <br />END OUT -SWING DOOR END IN -SWING DOOR <br />i i ADDITIONAL MANEUVERING SPACE IF <br />AND U-SHAPED PULLS ARE ACCEPTABLE. <br />APPROACH. SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN ACCESSIBLE ROUTE AND SHALL NOT <br />60" MIN. 60" MIN. <br />I-_ J A DOOR IS PROVIDED WITH A CLOSER <br />EXTEND INTO THE KNEE AND TOE SPACE UNDERNEATH THE LAVATORY MORE THAN 19". THIS CLEAR SPACE <br />SIDE DOOR SIDE DOOR <br />6. THE FOLLOWING PROVISIONS SHALL APPLY TO SWINGING DOORS INSTALLED IN A SERIES: <br />FIXED OR BUILT-IN SEATING , TABLES AND COUNTERS SHALL COMPLY WITH CBC SECTIONS 1127A.12 AND 1122B. <br />WHERE FIXED OR BUILT-IN SEATING, TABLES OR COUNTERS ARE PROVIDED IN ACCESSIBLE PUBLIC USE OR COMMON USE <br />36" MIN. 60" MIN. FINISH TO FINISH CLEAR <br />FINISH TO FINISH CLEAR <br />SHALL COMPLY WITH ALLOWABLE REACH RANGES. 17" MIN. <br />VANITY COUNTER WITH 25" MAX. LAVATORY <br />MANEUVERING MANEUVERING <br />34" 18" 34" MIN 2"� <br />t� <br />/ <br />AREAS, 5 PERCENT, BUT NEVER LESS THAN ONE, SHALL BE ACCESSIBLE AS FOLLOWS: <br />A. ACCESSIBLE ROUTE OF TRAVEL. A ROUTE OF TRAVEL SHALL LEAD TO AND THROUGH SUCH FIXED OR BUILT-IN <br />SHOWER SIDE CONTROL WALL ELEVATION FOR FIGURES 16.2 BACK CONTROL WALL <br />BUILT-IN LAVATORY SHOWN FIXTURE <br />' <br />CLEAR CLR CLEAR CL I <br />_/ <br />+ + <br />SEATING AREAS OR TABLES. <br />61/2" MAX. BOWL DEPTH SHOWN <br />� � <br />B. SEATING. IF SEATING SPACES FOR PERSONS IN WHEELCHAIRS ARE PROVIDED AT FIXED TABLES OR COUNTERS, <br />CLEAR FLOOR SPACE SHALL BE PROVIDED PER DETAIL 22 ON THIS SHEET. SUCH CLEAR FLOOR SPACE SHALL NOT <br />I <br />.< � I i <br />�____ RIM I COUNTER <br />I <br />v � W f <br />p " a I I I o " Q I <br />`\`I <br />w J v J <br />♦ <br />OVERLAP KNEE SPACE BY MORE THAN 19". <br />60" MIN. FINISH TO FINISH CLEAR J _J I 1 <br />KNE <br />I ♦ KNEE <br />o w `� o w `U <br />�� Q� <br />C. KNEE CLEARANCE. WHEN SEATING SPACES FOR PERSONS IN WHEELCHAIRS ARE PROVIDED AT FIXED TABLES OR <br />U 3 I 1 _J <br />= C� _ _ Q <br />,,,I <br />I t <br />� / 1 I <br />=� � 1 i z> � ,�� <br />� ,1 I 1 U <br />G�'�i <br />COUNTERS, KNEE SPACES AT LEAST 27"HIGH SHALL COMPLY WITH THE FOLLOWING FIGURES: <br />19" 48" MIN. 0" MIN. <br />MA . CLEAR LEAR <br />42"CLR. �30" CLR.L C <br />1 <br />BACK WALL � W o w w <br />1 112" MAX. 3" MAX. COMPARTMENT M o w I o 65 I <br />t-w I <br />- I <br />_ 0 <br />OPENING = - I% MAXIMUM <br />MAXI "' U' I 1 <br />I x Q w 6 <br />u M � o <br />- <br />I I � <br />x M U I <br />z I .< z TOE z <br />w �, <br />z <br />� 1 i 1 v �/ 1 <br />L___ <br />y 59"MIN. AT y y 36" MIN. y 59"MIN. AT y <br />DOOR PERMITTED <br />G. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 8112 POUNDS FOR EXTERIOR DOORS AND 5 POUNDS FOR <br />INTERIOR DOORS, SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND AT THE <br />F_____, I <br />z i , « 1 I \\ / 1 � <br />+ <br />,Q Q i 1/4" : 1'-0" SLOPE <br />1/4" : 1'-0' L PE w I <br />� J w 1 <br />z ,n <br />1/2" MAX. <br />� <br />1 1 = ----� <br />LO I i � 1 r �- z <br />N � <br />_ F.F. <br />FLR. MTD. W.C. TO SWING OVER WHEN DR. FLR. MTD. W.C. <br />OR 56" MIN. AT SWINGS IN OR 56" MIN. AT <br />HATCHED PORTION <br />WALL MTD. W.C. OF MANEUVERING WALL MTD. W.C. <br />CENTER PLANE OF SLIDING OR FOLDING DOORS. COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAYBE <br />UTILIZED TO MEET THESE STANDARDS. WHEN FIRE DOORS ARE REQUIRED, THE MAXIMUM EFFORT TO OPERATE THE <br />DOOR MAY BE INCREASED TO THE MINIMUM ALLOWABLE BY THE APPROPRIATE ENDORSEMENT AGENCY, NOT TO <br />EXCEED 15 POUNDS. <br />� = <br />o - 1 1 z <br />�' - --\ / \ <br />= U_ Z ______ w _______ <br />M o o 0 1l THRESHOLD <br />5"MIN. 5"MIN. "MIN <br />CLR. FLR. SPACE SPACE CLR. FLR. SPACE <br />FIGURE 8.2-A FIGURE 8.2-B <br />H. IF THE DOOR HAS A CLOSURE, THEN THE SWEEP PERIOD OF THE CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN <br />1 � 1 0 <br />� 0 I -1 1 I Of p <br />INSULATE <br />ACCESSIBLE COMPARTMENT WITH ACCESSIBLE COMPARTMENT WITH <br />POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3 INCHES FROM THE <br />�_ <br />= w FOLDING I FOLDING 1Q o <br />-----y -_-_-_ _ _ _ _ _ _ _ _ _ _ _ _ - -= y _ _ <br />r - - - - <br />rn o I w o <br />SEAT i i SEAT o <br />t _______1 1. _ /I z CD C OPTIONAL <br />18 MIN. 11"MIN PLUMBING <br />PIPES <br />C. THE FLOOR FINISH BENEATH THE LAVATORY SHALL EXTEND TO THE WALL. <br />SIDE OUT SWING DOOR SIDE IN -SWING DOOR <br />44" <br />LATCH, MEASURED TO THE LANDING EDGE OF THE DOOR. <br />I. THE TYPE OF LATCH AND LOCK FOR ALL DOORS SHALL BE IN ACCORDANCE WITH CBC SECTION 1008. <br />J. HAND -ACTIVATED DOOR LATCHING, LOCKING AND OPENING HARDWARE SHALL BE CENTERED BETWEEN 30" AND 44" <br />___ _ <br />- - - - - - - - - - - - - - - - ' ' - - - - - -1__ - __ <br />M z ENCLOSURE <br />¢ w <br />D. HOT WATER &DRAIN PIPES EXPOSED UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE COVERED. <br />MIN. CLR. <br />ABOVE THE FLOOR. LATCHING AND LOCKING DOORS THAT ARE HAND ACTIVATED AND ON AN ACCESSIBLE ROUTE <br />SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE, PANIC BARS, PUSH PULL ACTIVATING BARS <br />WHEELCHAIR SEATING SPACE WHEELCHAIR TABLE SPACE <br />M <br />FRONT 1/2" MAX. N o <br />THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES. <br />E. LAVATORY FAUCET CONTROLS AND OPERATION MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND <br />r---- _ GRAB BARS: <br />z 1 1 <br />OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE ABILITY TO GRASP THE HARDWARE. <br />KNEE SPACE IS NOT REQUIRED AT CHECKOUT COUNTERS OR SERVICE COUNTERS. <br />SEAT WALL THRESHOLD CN <br />N <br />SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE TO ACTIVATE <br />� <br />- � 1 36" x 48" 1 M SHALL BE INSTALLED IN <br />J � � <br />"' CLR. - ACCORDANCE WITH DETAILS 10 <br />LOCKED EXIT DOORS SHALL OPERATE CONSISTENT WITH NOTE H ABOVE, IN THE DIRECTION OF EGRESS <br />K. LEVER OR LEVER ACTUATED LATCHES OR LOCKS SHALL BE CURVED TO RETURN TO WITHIN 112" OF THE DOOR TO <br />24"MIN. 36"MIN. OPENING <br />CONTROLS SHALL BE NO GREATER THAN 5 POUND -FORCE. LEVER OPERATED, PUSH -TYPE, AND <br />M 1 1 M M <br />PREVENT CATCHING OF CLOTHING OF PERSONS DURING EGRESS. <br />D. HEIGHT OF WORK SURFACES. THE TOPS OF TABLES AND COUNTERS SHALL BE 28" TO 34" FROM THE FLOOR TO THE <br />ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. SELF -CLOSING <br />�- -- AND 12 OF THIS SHEET. <br />L. THE BOTTOM 10" OF ALL DOORS AND/OR GATES SHALL HAVE A SMOOTH, UNINTERRUPTED SURFACE TO ALLOW THE <br />GROUND. <br />VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS. <br />60" MIN. <br />DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. WHERE <br />FIGURE 16.2 ALTERNATE ROLL -IN SHOWER, PLAN VIEW ALTERNATE FIGURE 16.3 ALTERNATE ROLL -IN SHOWER <br />F. WHERE MIRRORS OR TOWEL FIXTURES ARE PROVIDED, AT LEAST ONE OF EACH SHALL BE ACCESSIBLE AND <br />FIGURE 8.3 <br />NARROW FRAME DOORS ARE USED, A 10" HIGH SMOOTH PANEL SHALL BE INSTALLED ON THE PUSH SIDE OF THE DOOR. <br />SHOWER SEAT WITH OPTIONAL ENCLOSURE, PLAN VIEW <br />SHALL BE MOUNTED WITH THE BOTTOM EDGE NO HIGHER THAN 40" FROM THE FLOOR. SEE DETAIL14 ON THIS <br />AMBULATORY ACCESSIBLE COMPARTMENT WITH FRONT OUT -SWING DOOR <br />SHEET FOR ADDITIONAL INFORMATION. <br />STORAGE & BUILT-INS <br />24 <br />SHOWER <br />16 <br />LAVATORY <br />12 <br />TOILET COMPARTMENTS <br />8 <br />DOORS <br />4 <br />Architecture + Planning <br />17911 Von Karman Ave. <br />Suite 200 <br />Irvine, CA 92614 <br />ktgy.com <br />949.851.2133 <br />KTGY Project No: 2017-0934 <br />Project Contact: Debbie Holland <br />Email: dholland@ktgy.com <br />Principal: Wil Wong <br />Project Designer: D. Schoolmeester <br />Project Director: Debbie Holland <br />Developer <br />ED OAK <br />INVlipS'I'I'�•'L��N I'S <br />4199 CAMPUS DRIVE <br />IRVINE, CA 92612 <br />PHONE NO. (714) 342-2502 <br />ff <br />O <br />0 <br />Z <br />Q <br />2 <br />H <br />r <br />O <br />Q <br />U <br />Q <br />z <br />Q <br />Q <br />z <br />Q <br />W <br />I.- <br />w <br />w <br />I- <br />= <br />I- <br />w <br />No. Date Description <br />It is the clients responsibility prior to or during construction to notify the architect in writing <br />of any perceived errors or omissions in the plans and specifications of which a contractor <br />thoroughly knowledgeable with the building codes and methods of construction should <br />reasonably be aware. Written instructions addressing such perceived errors or omissions <br />shall be received from the architect prior to the client or clients subcontractors proceeding <br />with the work. The client will be responsible for any defects in construction if these <br />procedures are not followed. <br />, ARcN�TF <br />\, �� �� <br />�� <br />� No. C29795 � <br />RENEWAL DATE <br />AUGUST 31, 2023 <br />F of CA_\1 <br />License Stamp <br />COMMON & PUBLIC <br />AREA ACCESSIBILITY <br />NOTES & DETAILS <br />AD-02 <br />J <br />C� <br />MG <br />W <br />�D <br />v J <br />U <br />�..�..� <br />= <br />U <br />z <br />^J <br />0- <br />F___ <br />V / <br />ILL <br />N <br />C) <br />CN <br />r <br />C) <br />C) <br />COPYRIGHT C <br />