Laserfiche WebLink
SA-2 Pressure Control Station Relocation <br />and Transmission Main Improvements <br />RFP No. 21-127 <br />Eric Yuen, PE, SE <br />Structural Engineer <br />Mr. Yuen has more than 14 years of experience in the design, <br />analysis, and detailing of structural engineering. Eric is <br />knowledgeable in reinforced concrete, masonry, structural steel <br />and wood frame design, and construction for a variety of building <br />and infrastructure projects including reservoirs and <br />water/wastewater treatment facilities, pump stations, lift stations <br />as well as seismic retrofit of existing structures. <br />EXPERIENCE <br />SA-3, SA-4 and SA-5 Vault Relocations, City of Santa Ana, CA. <br />Structural Engineer for the design and construction phases of three <br />pressure reducing valve vaults. The project included the design of <br />steel and ductile iron yard piping and connections to the existing City <br />system, pressure reducing valves, and concrete vaults. <br />Education: <br />BS, Civil Engineering, <br />California State Polytechnic <br />University, Pomona, 2007 <br />Registrations/Certifications: <br />Professional Civil Engineer, <br />California, No. 75983, 2009 <br />Professional Structural <br />Engineer, California, <br />No. 6177, 2014 <br />Professional Affiliations: <br />American Institute of Steel <br />Construction <br />Office Location: <br />San Dimas, CA <br />Total Years of Experience: <br />14 <br />Well No. 32 Rehabilitation. Citv of Santa Ana. Cf Structural Years with Tetra Tech: <br />Design Engineer. The project involved the preparation of a PDR and 14 <br />plans/specifications for the rehabilitation of the well facility. The <br />underground well would be scraped, cleaned and modified to be within an above ground CMU block <br />control building (housing mechanical and electrical rooms). The design also included civil, structural, <br />and electrical improvements to the park adjacent to the well site; a separate on -site generation sodium <br />hypochlorite building; 3,500 feet of 12-inch discharge pipe to John Garthe Reservoir; pressure control <br />vault and chemical injection vault for both Well 32 and the City's existing Well 24; and modification at <br />the reservoir to connect to the on -site piping. <br />..,jnty Water Dish ..,,«. <br />CA. Structural Engineer responsible for the design of four injection wells to be located within Centennial <br />Park in the City of Santa Ana for Orange County Water District. In addition to the engineering services <br />for the four injection wells, the project includes the design of the supply pipeline, backflush pipeline, <br />bridge crossing, two shared facility sites, a monitoring well site, site improvements, and paving of park <br />access roads and parking lots. <br />essure Reducing station Kelocatlon, Ivlounon Nlguell vvater ulstrwt, Laguna Niguel, CA. <br />Structural Engineer for the Pressure Reducing Station Upgrades for the District. This work included the <br />relocation of three pressure reducing stations. The station was located within the street right-of-way and <br />relocated in an existing parkway. <br />Mathis Oso-Bypass, Moulton Niguel Water District, Laguna Niguel, C. Structural Engineer for the <br />Flow Control/Pressure Reducing Station for the District. The existing pressure reducing station was <br />modified to include flow control capabilities. The piping arrangement within the existing vault was <br />modified, the size of valves was changed and the new flow control/pressure reducing station was <br />re -located within the street right of way in a left turn pocket. <br />Lvng oeat:n valve mepiaceMent, Long Beach Water uuparirnerit, Long oeach, Gr Structural <br />Engineer for improvements to an existing Flow Control/Pressure Reducing Station for the Department. <br />The improvements included the removal of existing piping and control valves with the replacement of <br />new butterfly valves and plunger valves. The pressure reduction in this station was approximately <br />180 psi and required that the plunger valve be designed and sized properly to handle such large drop at <br />this station. <br />TETRA TECH <br />