My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Item 18 - Traffic Signal Installation at Segerstrom Avenue and Rosewood Avenue
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2025
>
01/21/2025
>
Item 18 - Traffic Signal Installation at Segerstrom Avenue and Rosewood Avenue
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/27/2025 4:50:22 PM
Creation date
1/21/2025 3:12:07 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Public Works
Item #
18
Date
1/21/2025
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
286
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO.: 25-6030 <br />TRAFFIC SIGNAL INSTALLATION AT SEGERSTROM AVENUE AND ROSEWOOD <br />AVENUE <br />4.15 CONDUIT <br />Traffic signal, interconnect communications, and roadway lighting conduit shall conform <br />to the provisions in Section 86-1.02B, "Conduit and Accessories," and Section 87-1.03B, <br />"Conduit Installation," of the Caltrans Standard Specifications and these Special <br />Provisions. <br />Traffic signal conduit shall be schedule 80 PVC unless shown otherwise on the plans. SCE <br />service conduit shall be Schedule 40 PVC unless otherwise noted. Insulated bonding <br />bushings will be required. <br />All conduits, excluding SCE service conduits, shall be installed at the depth not less than <br />42" below finished grade. Only when conduits are to be installed between adjacent pull <br />boxes, from traffic signal pole to pull box or pull box to cabinet where the in-between <br />distance is too short to meet the 42" depth and the 45-degree sweep requirements, the <br />conduit may be installed at lower depth but not less than 18" below finished grade. <br />Unless shown otherwise on the plans, the minimum size of conduit shall be: <br />1. 2" between an electrolier and the adjacent pull box <br />2. 2" between a pedestrian push button post and the adjacent pull box <br />3. 2" between a IA signal standard <br />4. 3" between a Type 15 signal standard <br />5. 3" between signal standard with mastarm and the adjacent pull box <br />6. 24" between a controller cabinet and the adjacent pull box <br />7. 2" for advanced inductive loop detector runs <br />8. 2" between an overhead sign and the adjacent pull box <br />9. 4" for street crossings containing traffic signal conductors <br />10. 3" for traffic signal interconnect cable (SIC) only <br />11. 3" between pull boxes not otherwise specified <br />Curb terminations shall be as shown on Caltrans Standard Plan ES-5E, Type A, except that <br />conduit shown in Caltrans Standard Plan ES-5E, Type A shall be 2" (53 mm). <br />A Bull -Line pull tape or equivalent with a minimum tensile strength of 500 pounds shall <br />be installed in all conduits. <br />The ends of conduit and conduit fittings shall be provided with insulated and galvanized <br />bonding bushings. After conductors have been installed, the ends of conduits shall be <br />sealed with industry grade sealing compound. <br />Conduit installation by "Trenching in Pavement Method" shall not be allowed within the <br />traveled way of any public street without prior written authorization by the Engineer. <br />
The URL can be used to link to this page
Your browser does not support the video tag.