Laserfiche WebLink
HEMA-2025-03 – The A.L. Glines House (1804 N. Greenleaf Street) <br />September 23, 2025 <br />Page 3 <br /> <br /> <br />• Gable vents <br />• High-pitched cross gable and hipped roof <br />• Bay window <br />• Exterior and interior chimneys <br /> <br />The garage was converted to a living space at an unknown date. It displays a concrete <br />slab foundation, rectangular floor plan, wood frame, horizontal wood board wall cladding, <br />flat roof, and simple parapet. Double carriage doors are located on the east elevation. <br />Accordion doors span the north and west elevations. An unpermitted pergola is located <br />on the north elevation. Character defining features of the garage include the north façade <br />parapet and double carriage doors on the east façade. <br /> <br />Project Description <br /> <br />The project applicants are proposing a series of modifications to add a rear second story <br />addition to the residence, including the construction of a new roof and upper walls and <br />interior remodeling to create new interior living space, in addition to legalizing an <br />unpermitted upper-story bathroom addition. Construction of the new addition will produce <br />a gabled rear roof with asphalt shingles supported by stucco -clad walls flush with the <br />planes of the existing walls. All proposed windows will include wood sashes and f eature <br />hung and awning operability. Finally, work proposed for the detached garage will legalize <br />unpermitted alterations. <br /> <br />In consultation with staff, the applicant and project architect have made certain changes <br />to the project as originally proposed in order to ensure the project will be consistent with <br />the Secretary of the Interior’s Standards (SOIS). Although the project originally proposed <br />the inclusion of new vinyl windows on the proposed addition and retention of vinyl <br />windows where they exist, the project was modified to replace all proposed and existing <br />vinyl windows with hung and casement wood-sash windows generally consistent with the <br />materials, size, and operability of the historical windows on the second story. Staff initially <br />recommended a two-to-three-foot setback to ensure the exterior form of the addition will <br />be differentiated from the historic building. The project applicant stated this would not be <br />recommended because such a setback would reduce the interior plan of the addition by <br />four to six feet in total in three directions. Structurally, the setback would require <br />introducing new footings, steel columns and beams, which would reduce the useable <br />interior of the ground-floor spaces and would not be economically feasible relative to a <br />potential return on the investment. In coordination with staff , the applicants and project <br />architect agreed, as an alternative to a setback, to retain and/or restore the historical <br />eave-line molding, which will differentiate the new and old construction. <br /> <br />Exterior work on the residence is described in more detail below. <br /> <br />Alterations to the primary east façade would include: None <br /> <br />    <br />Historic Resources Commission 228 9/23/2025 <br />