09101/00
<br />15. Millwork / Cabinetry
<br />No millwork or shelving has been considered in storage rooms 104, 105, 108, 109, 110, 112, 115,
<br />128, 130, 132, Auto Shop 113, Kitchen 118, Office 140, Health 102. Rough plumbing will be
<br />installed where future sinks in future counters are indicated in Office 140, Health 102 and
<br />Kitchen 118.
<br />16. Specialty Metals
<br />Banner elements previously indicated on IvIVE's reference plans issued 9/30/93, are not included.
<br />Exterior patio deck awning elements are not included. Exterior elements shall be limited to items
<br />indicated on exterior elevations attached as part of this GivIP.
<br />17. Restrooms
<br />New restroom work shall be limited to Restrooms 148 and 151. The Locker Restrooms 120 an
<br />122 are not included. All rough plumbing, HVAC and electrical shall be installed, floor drainage
<br />and depressed slab work included. All finishes and accessories for Rooms 120 and 122 are not
<br />included.
<br />18. Unfinished Rooms
<br />Locker Rooms 120 and 122: Interior finishes, fixtures, demising walls, ceilings, lighting and
<br />mechanical distribution are not included. Plumbing shall be stubbed in for future fixtures and
<br />building slabs shall be depressed at future shower stalls.
<br />Handball Rooms 125 and 126: Interior finishes, wood flooring, demising walls, ceilings, lighting
<br />and mechanical distribution is not included.
<br />Exercise Room 129, Storage Room 128, Workout Room 131, Storage Room 130 and 132:
<br />Interior finishes, wood flooring, ceilings, lighting and mechanical distribution is not included.
<br />r
<br />19. Kitchen
<br />The Kitchen 118 will be cons with rough electrical, rough plumbing, and rough'HVAC.
<br />No finishes including sinks, faucets, millwork, flooring, wall coverings, marlite, FF &E or Health
<br />Department requirements are not included.
<br />20, Nlulti- Purpose Room
<br />The structural steel support for the folding partition will be installed and fireproofed. The folding
<br />partition as identifed on NIVE's reference plans issued 9/30/98 is not included in this GNU. The
<br />A/V system is not included. An acoustical ceiling shall replace the coved ceiling as indicated in
<br />MVE's reference plans issued 9/30/98.
<br />21. Fire Sprinkler System
<br />The interior system shall be upgraded in order to eliminate the exterior fire loop and hydrants.
<br />All interior heads shall be semi - recessed. No provisions of the fire suppression system have been
<br />considered for the Kitchen 118.
<br />22. Mechanical
<br />All HVAC units shall be installed and wired electrically. Distribution and finish shall be installed
<br />except at unfinished rooms: Locker Restrooms 120 and 122, Handball Rooms 125 and 126,
<br />Exercise Room 129, Storage Room 128, Workout Room 131, Storage Room 130 and 132,
<br />Kitchen 118. Rough plumbing stub -ins for future Drinking Fountains.
<br />23. Electrical
<br />Site electrical allowance of 530,000 has been established for pole lighting and wall packs
<br />necessary to provide the minimum code requirements. Security system conduits have been
<br />provided at all exterior doors and shall terminate at a single designated room. Security whin„
<br />devices and system are not included.
<br />F:\Data \PROJECTS \9929 \Contracts\Exh ibitA.doc