Laserfiche WebLink
09101/00 <br />15. Millwork / Cabinetry <br />No millwork or shelving has been considered in storage rooms 104, 105, 108, 109, 110, 112, 115, <br />128, 130, 132, Auto Shop 113, Kitchen 118, Office 140, Health 102. Rough plumbing will be <br />installed where future sinks in future counters are indicated in Office 140, Health 102 and <br />Kitchen 118. <br />16. Specialty Metals <br />Banner elements previously indicated on IvIVE's reference plans issued 9/30/93, are not included. <br />Exterior patio deck awning elements are not included. Exterior elements shall be limited to items <br />indicated on exterior elevations attached as part of this GivIP. <br />17. Restrooms <br />New restroom work shall be limited to Restrooms 148 and 151. The Locker Restrooms 120 an <br />122 are not included. All rough plumbing, HVAC and electrical shall be installed, floor drainage <br />and depressed slab work included. All finishes and accessories for Rooms 120 and 122 are not <br />included. <br />18. Unfinished Rooms <br />Locker Rooms 120 and 122: Interior finishes, fixtures, demising walls, ceilings, lighting and <br />mechanical distribution are not included. Plumbing shall be stubbed in for future fixtures and <br />building slabs shall be depressed at future shower stalls. <br />Handball Rooms 125 and 126: Interior finishes, wood flooring, demising walls, ceilings, lighting <br />and mechanical distribution is not included. <br />Exercise Room 129, Storage Room 128, Workout Room 131, Storage Room 130 and 132: <br />Interior finishes, wood flooring, ceilings, lighting and mechanical distribution is not included. <br />r <br />19. Kitchen <br />The Kitchen 118 will be cons with rough electrical, rough plumbing, and rough'HVAC. <br />No finishes including sinks, faucets, millwork, flooring, wall coverings, marlite, FF &E or Health <br />Department requirements are not included. <br />20, Nlulti- Purpose Room <br />The structural steel support for the folding partition will be installed and fireproofed. The folding <br />partition as identifed on NIVE's reference plans issued 9/30/98 is not included in this GNU. The <br />A/V system is not included. An acoustical ceiling shall replace the coved ceiling as indicated in <br />MVE's reference plans issued 9/30/98. <br />21. Fire Sprinkler System <br />The interior system shall be upgraded in order to eliminate the exterior fire loop and hydrants. <br />All interior heads shall be semi - recessed. No provisions of the fire suppression system have been <br />considered for the Kitchen 118. <br />22. Mechanical <br />All HVAC units shall be installed and wired electrically. Distribution and finish shall be installed <br />except at unfinished rooms: Locker Restrooms 120 and 122, Handball Rooms 125 and 126, <br />Exercise Room 129, Storage Room 128, Workout Room 131, Storage Room 130 and 132, <br />Kitchen 118. Rough plumbing stub -ins for future Drinking Fountains. <br />23. Electrical <br />Site electrical allowance of 530,000 has been established for pole lighting and wall packs <br />necessary to provide the minimum code requirements. Security system conduits have been <br />provided at all exterior doors and shall terminate at a single designated room. Security whin„ <br />devices and system are not included. <br />F:\Data \PROJECTS \9929 \Contracts\Exh ibitA.doc <br />