Laserfiche WebLink
(2) Acceptability criteria. living and sleeping rooms shall include at least one window. A ceiling or wall type light fixture shall be <br />present and working in the bathroom and kitchen area. At least two electric outlets one of which may be an overhead light, shall <br />be present and operable in the living area, kitchen area, and each bedroom area. <br />(f) Structure and materials <br />(1) Performance requirement. The dwelling unit shall be structurally sound so as not to pose any threat to the health and <br />safety of the occupants and so as to protect the occupants from the environment. <br />(2) Acceptability criteria. Ceilings, walls, and floors shall not have any serious defects such as severe bulging or leaning, large <br />holes, loose surface materials, severe buckling or noticeable movement under walking stress, missing parts or other serious <br />damage. The roof structure shall be firm and the roof shall be weather tight. The exterior wall structure and exterior wall surface <br />shall not have any serious defects such as serious leaning, buckling, sagging, cracks or holes, loose siding, or other serious <br />damage. The condition and equipment of interior and exterior stairways, halls, porches, walkways, etc., shall be such as not to <br />present a danger of tripping or falling. Elevators shall be maintained in safe and operating condition. <br />(g) Interior air quality <br />(1) Performance requirement. The dwelling unit shall be free of pollutants in the air at levels which threaten the health of the <br />occupants. <br />(2) Acceptability criteria. The dwelling unit shall be free from dangerous levels of air pollution from carbon monoxide, sewer <br />gas, fuel gas, dust, and other harmful air pollutants. Air circulation shall be adequate throughout the unit. Bathroom areas shall <br />have at least one openable window or other adequate exhaust ventilation. <br />(h) Water supply <br />(1) Performance requirement. The water supply shall be free from contamination. <br />(2) Acceptability criteria. The unit shall be served by an approved public or private sanitary water supply. <br />(i) Lead -based paint <br />(1) Purpose and applicablity. The purpose of this paragraph is to implement the provisions of section 302 of the Lead -Based <br />Paint Poisoning Prevention Act, 42 U.S.C. 4822, by establishing procedures to eliminate as far as practicable the hazards of <br />lead -based paint poisoning with respect to existing housing units for which Requests For Lease Approval are made under this <br />part. This paragraph is promulgated under the authorization granted in 24 CFR 35.24(b)(4) and supersedes, with respect to all <br />housing to which it applies, the requirements prescribed by subpart C of 24 CFR part 35. The requirements of paragraph (i)(4) of <br />this section are applicable to units for which initial inspection under Sec. 882.209(h)(1) or periodic inspection under Sec. <br />882.211(b) is made on or after May 1, 1987. The requirements of this paragraph do not apply to 0- bedroom units. The <br />requirements of subpart A of 24 CFR part 35 apply to all units constructed prior to 1978 covered by a Housing Assistance <br />Payments <br />Contract under this subpart. <br />(2) Definitions -- Applicable surface. All intact and nonintact interior and exterior painted surfaces of a residential structure. <br />Chewable surface. All chewable protruding painted surfaces up to five feet from the floor or ground, which are readily <br />accessible to children under seven years of age, e.g., protruding corners, windowsills and frames, doors and frames, and other <br />protruding woodworks. <br />Defective paint surface. Paint on applicable surfaces that is cracking, scaling, chipping, peeling or loose. <br />Elevated blood lead level or EBL. Excessive absorption of lead, that is, a confirmed concentration of lead in whole blood of 25 <br />ugldl (micrograms of lead per deciliter of whole blood) or greater. <br />Lead -based paint. A paint surface, whether or not defective, identified as having a lead content greater than or equal to 1 <br />mglcm121. <br />(3) Defective paint. In the case of a unit, for a Family which includes a child under the age of seven years, which was <br />constructed prior to 1978, the initial inspection under Sec. 882.209(h)(1), and each periodic inspection under Sec. 882.211(b), <br />shall include an inspection for defective paint surfaces. If defective paint surfaces are found, treatment as required by 24 CFR <br />35.24(b)(2)(ii) shall be required in accordance with Sec. 882.209(h) or Sec. 882.211(b) -(c), as appropriate. Correction of <br />defective paint conditions discovered at periodic inspection shall be completed within 30 days of PHA notification to the Owner. <br />When weather conditions prevent completion of repainting of exterior surfaces within the 30 -day period, repainting may be <br />delayed, but covering or removal of the defective paint must be completed within the prescribed period. <br />(4) Chewable surfaces. In the case of a unit constructed prior to 1978, for a Family which includes a child under the age of <br />seven years with an identified EBL condition, the initial inspection under Sec. 882.209(h)(1), or a periodic inspection under Sec. <br />882.21l(b), shall include a test for lead -based paint on chewable surfaces. Testing shall be conducted by a Slate or local health <br />or housing agency, an inspector certified or regulated by a State or local health or housing agency or an organization recognized <br />by HUD. Lead content shall be tested by using an X -ray fluorescence analyzer (XRF) or other method approved by HUD. Test <br />readings of 1 mglcm <SUP >2<ISUP> or higher using an XRF shall be considered positive for presence of lead -based paint. <br />16 <br />